HomeMy WebLinkAbout238.10 (replaced 2020)PLAN
INLET PIPE
(FLOW THROUGH)
OUTLET PIPE
OPTIONAL PARALLEL TANK
ACCESS RISERS,
SEE NOTE 6
ACCESS RISERS PER
STD. PLAN 235.10
24 " ACCESS MANHOLE WITH
BOLT LOCKING RING AND COVER
CLEAN DRAIN ROCK (1-1/2" - 3") TO TOP OF TANK,
2' MIN., 5' MAX. BEYOND EDGES, SEE NOTE 4
SETTLING VAULT OR TYPE 2
CATCH BASIN (CB) IF REQUIRED
SECTION A
INFILTRATION TANK
(SIZE AS REQUIRED)
1" HOLES AS
REQUIRED,
SEE NOTE 10 CLEAN DRAIN ROCK (1-1/2" - 3") TO TOP
OF TANK, 2' MIN., 5' MAX. BEYOND EDGES,
1' MIN. BELOW BOTTOM, SEE NOTE 4
TYPE 2 CB OR SETTLING
VAULT IF REQUIRED
2" MIN. DIA AIR VENT PIPE WELDED TO TANK
(REQUIRED IF NO ACCESS RISER ON TANK)
OVERFLOW RISER FOR
INFILTRATION ONLY. FOR
DETENTION/RETENTION SEE
STD. PLAN 235.00
OVERFLOW STRUCTURE,
54" MIN. DIA TYPE 2 CB
GEOTEXTILE (TOP ONLY), SEE NOTE 4
2'
MAX.
50'
MAX.100' MAX.50'
MAX.
2' MIN.4'
MIN.
36" MIN. DIA (TYP.)
NOTES:
1.THIS DETAIL IS A SCHEMATIC REPRESENTATION ONLY. ACTUAL CONFIGURATION WILL VARY DEPENDING ON SPECIFIC SITE CONSTRAINTS AND APPLICABLE DESIGN
CRITERIA.
2.MINIMUM TANK DIAMETER IS 36 INCHES.
3.METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5.
4.GEOTEXTILE FOR UNDERGROUND DRAINAGE, CLASS A, TO BE PLACED OVER CLEAN DRAIN ROCK, PER WSDOT STANDARD SPECIFICATIONS SECTION 9-33.2(1).
5.THE PROPOSED BOTTOM SHALL BE AT LEAST 3 FEET ABOVE THE SEASONAL HIGH WATER LEVEL AND HAVE AT LEAST 3 FEET OF PERMEABLE SOIL BENEATH THE
BOTTOM.
6.ACCESS RISERS REQUIRED CENTERED NO MORE THAN 50 FEET FROM ANY LOCATION WITHIN THE INFILTRATION TANK.
7.H-20 LIVE LOADS MUST BE ACCOMMODATED FOR TANKS LYING UNDER PARKING AREAS, ROADWAYS, AND ACCESS ROADS.
8.PIPE MATERIAL, JOINTS, AND PROTECTIVE TREATMENT FOR TANKS SHALL BE IN ACCORDANCE WITH SECTIONS 7-04 AND 9-05 OF THE WSDOT/APWA STANDARD
SPECIFICATIONS.
9.ALL TANK ACCESS OPENINGS MUST BE READILY ACCESSIBLE BY MAINTENANCE VEHICLES.
10.THE NUMBER AND SPACING OF THE HOLES SHOULD BE SUFFICIENT TO ALLOW COMPLETE UTILIZATION OF THE AVAILABLE INFILTRATION CAPACITY OF THE SOILS WITH
A SAFETY FACTOR OF 2.0 WITHOUT JEOPARDIZING THE STRUCTURAL INTEGRITY OF THE TANK.
11.WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING
TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE.
12.SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.
A
2' MIN.
SEE NOTE 11 (TYP.)
6" MIN.
SEE NOTE 11 (TYP.)
FINISH GRADE
6"
2' MIN.
36" MIN.
36" MIN.
"FLOW-THROUGH" SYSTEM SHOWN SOLID.
DESIGNS FOR "FLOW BACKUP" SYSTEM AND
PARALLEL TANKS SHOWN DASHED
CLOSED BOTTOM
SAME SIZE AS INLET PIPE, 12"
MIN. DIA.
TYPICAL INFILTRATION TANK
STD. PLAN - 238.10
PUBLIC WORKS
DEPARTMENT
APPROVED:
DATEGregg Zimmerman
Public Works Administrator
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS)
DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878
9/28/2018 | 9:45 AM PDT