HomeMy WebLinkAbout404.1A A
PLAN VIE
SEWER
SECTION A -A
VALVE BOX LID WITH EARS
IN DIRECTION OF SEWER 2" SQUARE
MAIN AND WORD "SEWER" OPERATING NUT
CAST INTO IT
AIL
4-1/4" DIA.
1/8" MIN. THICKNESS
'IECE CAST IRON VALVE
X, RICH -SEATTLE TYPE 1" STEEL
OLYMPIC FOUNDARY
LENGTH AS REQUIRED
1/8" MIN. THICKNESS
/ 2-1/4" INSIDE MEASUREMENT
2-1/4" DEPTH
VALVE OPERATING NUT
EXTENSION
T
3,.
38"
MIN.
VALVE OPERATION NUT EXTENSION NOTE:
WIDTH
WHITE POST
EXTENSIONS ARE REQUIRED WHEN VALVE NUT IS MORE
62"
THAN THREE (3) FEET BELOW FINISHED GRADE. =III .III_
EXTENSIONS ARE TO BE A MINIMUM OF ONE (1) FOOT
LONG. ONLY ONE EXTENSION TO BE USED PER VALVE. �-
24"
NOTE: ALL EXTENSIONS ARE TO BE MADE OF STEEL,
SIZED AS NOTED, AND PAINTED WITH TWO COATS OF
METAL PAINT.
VALVE MARKER POST
VALVE MARKER NOTES:
VALVE MARKERS SHALL BE EQUAL TO CARSONITE
UTILITY MARKER
VALVE MARKER POST TO BE USED FOR ALL MAIN
LINE VALVES OUTSIDE PAVED AREAS
VALVE MARKER POST SHALL IDENTIFY VALVES AS
SEWER
Y
SEWER VALVE STD. PLAN - 404.1
* + PUBLIC WORKS OPERATING NUT EXTENSION