HomeMy WebLinkAbout119LUMINAIRE WARES WILL BE A CONTINUOUS RUN FROM FUSE HOLDER TO FIXTURE WITH NO SPLICES. � FUSE KITS WICK DISCONNECT 3 AMP IN UNE FUSE KITS S.E.C. OR EQUAL REFER TO WSOOT LOCKING UO STANDARD DUTY JUNCTION BOX TYPES 1 & 2 STANDARD PLAN J-40.10-03 GROUND LUG SPLLICE KITS CLEAR EPDXY 2" MIN. GROUT WIRE RUNS ON ALL THRU UNDER POLE BA' 4" CONCRETE PAD 5" 9• sr 2' MIN. 08 BARE COPPER GROUND WIRE 1 GROUND CLAMP I -/8 EQUIPMEN NREW/GREEN INSULATION 2" PVC CONDUIT FROM SERVICE CABINET SYSTEM 2 - LIGHTING SYSTEM WIRES TO CONTACTOR (SIZED AS REOV) CONCRETE - FOIINDATION 5/8°x8' COPPER CLAD GROUND ROD GROUND ROD LUMINAIRE LUMINAIRE WIRES WILL BE 112 AWG IN A JACKETED CABLE. I GREEN INSULATED WIRE 0 FIXTURE GROUND LUG 1/4' DRAM 7 S0. OR DIA. NOTES: 1. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 2. IF THE FIXTURE MANUFACTURER HAS MADE PROVISION FOR THE ATTACHMENT OF A GROUND WIRE A GREEN INSULATED WIRE OF THE SAME SIZE SHALL BE RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE HANDHOLE. IF THE FIXTURE MANUFACTURER HAS A GROUND LUG A #8 GREEN INSULATED WIRE SHALL BE RUN FROM THE FIXTURE GROUND LUG TO THE POLE GROUND LUG. OF CONCRETE FOUNDATION TO LEVEL WITH TOP OF SIDEWALK CURB, STD. PLAN — 119 [_(4 PUBLIC WORKS TYPICAL LIGHTING APPROVEDU DEPARTMENT UNDERGROUND SYSTEM 4o