Loading...
HomeMy WebLinkAboutP_Lighting_Plans_220920_v1© 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM OWNER GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 119 1ST AVENUE SOUTH, SUITE 110 SEATTLE, WA 98104 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER HENDERSON ENGINEERS 8345 LENEXA DRIVE, #300 LENEXA, KS 66214 816.663.8700 HENDERSONENGINEERS.COM MEP ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM DEVELOPER 4/4/2022 5:40:59 PM 21032 SEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER 04.27.2022 Author 1901 OAKESDALE AVENUE SW RENTON, WA 98057 Checker REV DESCRIPTION DATE TEL FAX WWW.HENDERSONENGINEERS.COM 2150004931 WA. CORPORATE NUMBER: 1754 06/30/22 8345 LENEXA DRIVE, SUITE 300 LENEXA, KS 66214 913.742.5000 913.742.5001 THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF IT IS NOT TO BE USED FOR PURPOSES. LICENSE #LICENSE #LICENSE # ANDRIA J. ODROWSKI 56705 CONSTRUCTION PRELIMINARY SUBMITTAL E000 ELECTRICAL GENERAL NOTES AND LEGEND ELECTRICAL SYMBOLS THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS OR ABBREVIATIONS ARE USED.V3.01 STANDARD MOUNTING HEIGHTS INSTALL DEVICES/OUTLET BOXES AT THE MOUNTING HEIGHTS SHOWN ABOVE UNO IN THE CONSTRUCTION DOCUMENTS. MOUNTING HEIGHTS LISTED ABOVE, OR ELSEWHERE IN THE CONSTRUCTION DOCUMENTS, ARE AFF OR AFG TO BOTTOM, UNO. ALL DEVICES SHALL BE INSTALLED IN COMPLIANCE WITH CURRENT ADA AND LOCAL REQUIREMENTS. AUDIBLE APPLIANCE (CENTERLINE) ALARM (TOP OF DEVICE) ANNUNCIATOR PANEL (TOP OF DISPLAY) CONTROLS (TOP OF DEVICE) DATA WALL OUTLET EXIT SIGN (WALL MOUNTED) FIRE ALARM ANNUNCIATOR PANEL (TOP OF DISPLAY) FIRE ALARM BELL (EXTERIOR) (CENTERLINE) FIRE ALARM CONTROL PANEL/UNIT (TOP OF DISPLAY) INTERCOM (TOP OF DEVICE) PULL STATION (TOP OF DEVICE) RECEPTACLE RECEPTACLE (ABOVE COUNTER) RECEPTACLE (CLOCK) (CENTERLINE) RECEPTACLE (EQUIPMENT ROOMS) (TOP OF DEVICE) RECEPTACLE (EXTERIOR) RECEPTACLE (GARAGES) REMOTE INDICATING LIGHT (EQUIPMENT ROOMS) (TOP OF DEVICE) REMOTE INDICATING LIGHT (FINISHED AREAS) SAFETY SWITCH (TOP OF DEVICE) STARTER (TOP OF DEVICE) SWITCH (TOP OF DEVICE) TELEPHONE WALL OUTLET (TOP OF DEVICE) TELECOMMUNICATIONS BACKBOARD TELEVISION OUTLET VISIBLE APPLIANCE (CENTERLINE) 84" 46" 60" 46" SAME AS ADJACENT DEVICE, UNO 92" 60" 120" 60" 46" 46" 16" +6" ABOVE BACKSPLASH/COUNTER, 40" MAX 84" 46" 24" 24" 46" CEILING 46" 46" 46" 46" 6" REFER TO DRAWINGS 84" AF AMPERE FUSE SIZE AFC ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT AIC AMPERE INTERRUPTING CAPACITY AS AMPERE SWITCH SIZE AT AMPERE TRIP SETTING ATS AUTOMATIC TRANSFER SWITCH AV AUDIO VISUAL BAS BUILDING AUTOMATION SYSTEM BKR BREAKER C CONDUIT CAT CATEGORY CATV CABLE TELEVISION SYSTEM CCTV CLOSED CIRCUIT TELEVISION CD CANDELA CKT CIRCUIT CODE APPLICABLE CODE ADOPTED BY JURISDICTION CT CURRENT TRANSFORMER CTR CENTER CTRL CONTROL/CONTROLLED CVD CUMULATIVE VOLTAGE DROP D/DEMO DEMOLITION DPDT DOUBLE-POLE, DOUBLE-THROW DPST DOUBLE-POLE, SINGLE-THROW E/ETR/EX EXISTING TO REMAIN EC ELECTRICAL CONTRACTOR EF EXHAUST FAN EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM ELV ELECTRONIC LOW-VOLTAGE EWC ELECTRIC WATER COOLER FAAP FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FCA FAULT CURRENT AMPS AVAILABLE FCU FAN COIL UNIT FF FINISHED FLOOR FLA FULL LOAD AMPS FLR FLOOR GC GENERAL CONTRACTOR GEC GROUNDING ELECTRODE CONDUCTOR GES GROUNDING ELECTRODE SYSTEM GFR GROUND FAULT RELAY G GROUND IG ISOLATED GROUND ISC SHORT CIRCUIT CURRENT JB/J-BOX JUNCTION BOX LF LINEAR FEET LRA LOCKED ROTOR AMPS LTG/LTS LIGHTING/LIGHTS MAU MAKE-UP AIR UNIT MAX MAXIMUM MCA MINIMUM CIRCUIT AMPACITY MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MFR MANUFACTURER MIN MINIMUM MLO MAIN LUGS ONLY MLV MAGNETIC LOW-VOLTAGE MOCP MAXIMUM OVERCURRENT PROTECTION MTD MOUNTED N/A NOT APPLICABLE NF NON-FUSED NL NIGHT LIGHT (24HR ON) NRTL NATIONALLY RECOGNIZED TESTING LABORATORY (CSA,ETL,NSF,UL) NTS NOT TO SCALE OS OCCUPANCY SENSOR P POLE PART PARTIAL CIRCUIT PH/Ø PHASE PNL PANEL PNLBD PANELBOARD PROVIDE FURNISH AND INSTALL PT POTENTIAL TRANSFORMER QTY QUANTITY R/REL RELOCATE RCPT RECEPTACLE RLA RUNNING LOAD AMPS RTU ROOFTOP UNIT SCCR SHORT-CIRCUIT CURRENT RATING SD SMOKE DUCT DETECTOR SF SQUARE FEET SPDT SINGLE-POLE, DOUBLE-THROW SPST SINGLE-POLE, SINGLE-THROW SSBJ SUPPLY-SIDE BONDING JUMPER ST SHUNT TRIP SWBD SWITCHBOARD SWGR SWITCHGEAR TBB TELECOMMUNICATIONS BONDING BACKBONE TBD TO BE DETERMINED TGB TELECOMMUNICATIONS GROUND BUS BAR TL TWISTLOCK TMGB TELECOMMUNICATIONS MAIN GROUND BUS BAR TX/XFMR TRANSFORMER TYP TYPICAL U/F UNDERFLOOR U/G UNDERGROUND U/S UNDERSLAB UH UNIT HEATER UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY VD VOLTAGE DROP VFD VARIABLE FREQUENCY DRIVE VS VACANCY SENSOR W WIRE W/WITH WP WEATHER PROOF WR WEATHER RESISTANT WT WATERTIGHT XP EXPLOSION-PROOF ABBREVIATIONS THROUGHOUT THE DRAWINGS DIFFERENT LINETYPES ARE USED IN COMBINATION WITH THE SYMBOLS TO INDICATE THE STATUS OF ITEMS AS EXISTING, TO BE DEMOLISHED, TO BE INCLUDED AS PART OF NEW WORK AND/OR ITEMS WHICH ARE ANTICIPATED TO BE PROVIDED IN THE FUTURE. THE STATUS OF ITEMS USING THESE LINETYPES ARE RELATIVE TO THE VIEW IN WHICH THEY APPEAR. PHASING SHOWN IN DRAWINGS IS NOT INTENDED TO FULLY DESCRIBE ALL NECESSARY CONSTRUCTION PHASING, WHICH IS DETERMINED BY THE CONTRACTOR AS PART OF THEIR RESPONSIBILITIES. ANY SUCH PHASES DESCRIBED IN THE CONSTRUCTION DOCUMENTS ARE GENERAL AND ONLY INTENDED TO INDICATE A BROAD ORDER FOR THE SAKE OF DESCRIBING THE PROJECT. THE FOLLOWING LINETYPES MAY BE USED ON ANY DEVICE, EQUIPMENT, NOTE, LINE, SHAPE, ETC. EXISTING DEMOLISH NEW FUTURE LINETYPE LEGEND B B T SIGNALING SIGNALING BELL SIGNALING BUZZER LV TRANSFORMER 1 CU 1 1 E1 1 1 1 1 1 1 E1 ANNOTATION MECHANICAL OR FIRE PROTECTION PLAN NOTE CALLOUT PLUMBING PLAN NOTE CALLOUT ELECTRICAL OR FIRE ALARM PLAN NOTE CALLOUT TECHNOLOGY PLAN CALLOUT PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED AND INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT SCHEDULES EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR INSTALLED) MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND INSTALLED UNLESS NOTED OTHERWISE) CONNECTION POINT OF NEW WORK TO EXISTING DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER SECTION CUT DESIGNATION DEDICATED EQUIPMENT ACCESS TILE ACCESS PANEL 57 P1-3,5,7 OR P1 3 CIRCUITING & WIRING HOMERUN TO PANELBOARD. INFORMATION AT ARROWS ARE CIRCUIT NUMBERS AND PANELBOARD FOR TERMINATION. REFER TO PANELBOARD SCHEDULES FOR BRANCH CIRCUIT CONDUCTOR SIZES. INDICATES RELAY NUMBER CIRCUIT CONTINUATION OR PARTIAL CIRCUIT CONDUIT CONCEALED CONDUIT CONCEALED (EMERGENCY) CONDUIT IN/UNDER FLOOR/GROUND CONSTRUCTION EXPOSED CONDUIT EXPOSED CONDUIT (EMERGENCY) FLEXIBLE CONDUIT LOW VOLTAGE CABLE (NOT ROUTED IN CONDUIT) CONDUIT TURNING DOWN CONDUIT TURNING UP CONNECTION POINT OR EQUIPMENT TERMINATION EQUIPMENT TERMINATION EM EM [R-#] WHERE TICK MARKS ARE SHOWN, THE FOLLOWING SHALL GOVERN: SWITCHED HOT (PHASE) CONDUCTORS (SHOWN TRAILING NEUTRAL) NEUTRAL (GROUNDED) CONDUCTOR UNSWITCHED HOT (PHASE) CONDUCTORS (SHOWN LEADING NEUTRAL) NOTE: HASH MARKS INDICATE QUANTITY OF CONDUCTORS EQUIPMENT GROUNDING CONDUCTOR IN CONDUIT (GREEN INSULATION OR BARE) ISOLATED GROUNDING CONDUCTOR IN CONDUIT (GREEN INSULATION WITH YELLOW TRACER) CONDUCTOR TICK MARK LEGEND *PROVIDE ADDITIONAL CONDUCTORS THROUGH ENTIRE CIRCUIT (SWITCHED, UNSWITCHED/EM, ETC.) AS INDICATED THROUGHOUT CONSTRUCTION DOCUMENTS AND AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM. **REFER TO SPECIFICATIONS FOR LIMITATIONS ON SHARING NEUTRAL (GROUNDED) CONDUCTORS. DO NOT CIRCUIT AS A MULTI-WIRE BRANCH CIRCUIT, UNO. ***PROVIDE ADDITIONAL ISOLATED GROUNDING CONDUCTORS WHERE INDICATED. REFER TO SPECIFICATIONS, PLANS, NOTES, WIRING AND CONTROL DIAGRAMS FOR ADDITIONAL CIRCUITING REQUIREMENTS. WHERE TICK MARKS ARE NOT SHOWN, THE FOLLOWING SHALL GOVERN: BRANCH CIRCUIT CONDUCTOR TABLE # OF POLES 1P 2P 3P HOT (PHASE)* (1) (2) (3) NEUTRAL (GROUNDED)** (1) UNO (1) UNO (1) UNO GROUNDING*** (1) (1) (1) A a LIGHT FIXTURE a A LIGHTING LIGHT FIXTURE CIRCUITED AS A NIGHT LIGHT (NL) EMERGENCY LIGHT FIXTURE WITH EMERGENCY LIGHTING BATTERY PACK OR CONNECTED TO EMERGENCY SOURCE NIGHT LIGHT/EMERGENCY LIGHT FIXTURE WITH EMERGENCY BATTERY PACK OR CONNECTED TO EMERGENCY SOURCE LIGHT FIXTURE WITH DUAL BALLASTS CIRCUITED SEPARATELY (SHADING IMPLIES EMERGENCY LIGHT FIXTURE) LIGHTING TRACK (# INDICATES RELAY NUMBER) MIRROR LIGHTS EXTERIOR PARKING LOT LIGHT FIXTURE EXTERIOR PEDESTRIAN POST TOP LIGHT FIXTURE EXTERIOR LIT BOLLARD LIGHT FIXTURE EXIT SIGN - CEILING / WALL MOUNTED, ARROWS AS INDICATED, FACE HATCHED EMERGENCY LIGHTING UNIT EQUIPMENT WITH BATTERY PACK - CEILING/WALL MOUNTED AFEA (AREA FOR EVACUATION ASSISTANCE) SIGN - CEILING/WALL MOUNTED, ARROWS AS INDICATED = LOWER CASE LETTER IS SWITCH IDENTIFIER = UPPER CASE LETTER INDICATES LIGHT FIXTURE TYPE = WALL MOUNT = ARROW INDICATES AIMING DIRECTION REFER TO LIGHT FIXTURE SCHEDULE FOR MORE INFORMATION. [#] 200/3/150/3R 30/3/15/1/3R 2 VFD ELECTRICAL PANELBOARD (SURFACE OR FLUSH MOUNT) ELECTRICAL CABINET (SURFACE OR FLUSH MOUNT), TYPE AS NOTED PLYWOOD TERMINAL BOARD FOR TELEPHONE SYSTEM, UNO. SIZE AS NOTED SWITCHBOARD OR MOTOR CONTROL CENTER ON HOUSEKEEPING PAD ELECTRICAL DISTRIBUTION PANELBOARD TRANSFORMER DISCONNECT SWITCH - "200/3/150/3R" DENOTES AMPERES/POLE/FUSE/NEMA ENCLOSURE RATING, NF= NON-FUSED, CB= CIRCUIT BREAKER (200/3/CB), NO VALUE (200/3/150) FOR NEMA ENCLOSURE MEANS STANDARD NEMA 1 RATING COMBINATION DISCONNECT (SAFETY) SWITCH AND MOTOR STARTER "30/3/15/1/3R" DENOTES AMPERES/POLE/FUSE/NEMA STARTER SIZE/NEMA ENCLOSURE RATING. NF= NON-FUSED, CB= CIRCUIT BREAKER (30/3/CB/1), NO VALUE (200/3/150/1) FOR NEMA ENCLOSURE MEANS STANDARD NEMA 1 ENCLOSURE RATING MAGNETIC MOTOR STARTER, NEMA SIZE AS NOTED. 3-POLE, UNO VARIABLE FREQUENCY DRIVE INDICATING LIGHT EMERGENCY POWER OFF BUTTON STOP-START PUSH BUTTON CONTROL STATION HAND-OFF-AUTO PUSH BUTTON CONTROL STATION MUSHROOM-TYPE PUSH BUTTON OVERHEAD PADDLE FAN POWER EQUIPMENT Z,B B B B BR DS E EP IC K N1 NA NM SS N2 NURSE CALL (HOSPITAL) CODE BLUE PUSHBUTTON STATION BED RECEPTACLE DUTY STATION STAFF EMERGENCY ASSIST STATION PATIENT EMERGENCY PULL CORD STATION INTERCOM NURSE CALL KEY SWITCH NURSE CALL BEDSIDE STATION - SINGLE PATIENT NURSE CALL BEDSIDE STATION - DOUBLE PATIENT NURSE CALL VISUAL ANNUNCIATOR PANEL STAFF STATION (NORMAL, EMERGENCY & CODE BLUE) NURSE CALL MASTER STATION DOME LIGHT - CEILING MOUNTED, B = BUZZER DOME LIGHT - WALL MOUNTED, B = BUZZER ZONE DOME LIGHT, B = BUZZER A # A A J J T GFCIOR G EM OR SIMPLEX RECEPTACLE - NEMA 5-20R, UNO DUPLEX RECEPTACLE - NEMA 5-20R, UNO DOUBLE DUPLEX RECEPTACLE - NEMA 5-20R, UNO SPECIAL RECEPTACLE - NEMA TYPE AS NOTED TWIST-LOCK TYPE RECEPTACLE BLANK FACE GFCI FEED THROUGH DEVICE GFCI TYPE RECEPTACLE* ISOLATED GROUND TYPE RECEPTACLE* EMERGENCY RECEPTACLE* RECEPTACLE INSTALLED ABOVE COUNTER OR BACKSPLASH* RECEPTACLE INSTALLED IN CEILING* RECEPTACLE INSTALLED IN FLOOR* RECEPTACLE INSTALLED VIA DROP CORD* ADDITIONAL RECEPTACLE LETTER DESIGNATIONS AS FOLLOWS: C = AUTOMATICALLY CONTROLLED CH = CLOCK HANGER TYPE G = RCPT PROTECTED BY GFCI CIRCUIT BREAKER OR UPSTREAM GFCI DEVICE H = HORIZONTALLY MOUNTED S = MANUALLY SWITCHED SP / TVSS = SURGE PROTECTION TR = TAMPER RESISTANT TV = TELEVISION USB = USB/DUPLEX WP = WEATHER PROOF COVER WR = WEATHER RESISTANT MULTI-OUTLET ASSEMBLY TELEPHONE OUTLET DATA OUTLET MULTI-SERVICE OUTLET; TELEPHONE AND DATA ABOVE COUNTER, TYP WALL, TYP FLOOR, TYP MULTI-SERVICE POWER POLE WITH TELEPHONE, DATA AND POWER OUTLETS A = TYPE, REFER TO PLANS, SCHEDULES AND SPECIFICATIONS MULTI-SERVICE FLOOR BOX WITH TELEPHONE, DATA AND POWER OUTLETS A = TYPE, REFER TO PLANS, SCHEDULES AND SPECIFICATIONS POKE THROUGH, A = TYPE, REFER TO PLANS, SCHEDULES AND SPECIFICATIONS THERMOSTAT CEILING/FLOOR MOUNT JUNCTION/OUTLET BOX WALL MOUNT JUNCTION/OUTLET BOX S # BOXES, LIGHTING CONTROL & WIRING DEVICES SWITCH LETTER DESIGNATIONS AS FOLLOWS: BLANK = SINGLE POLE 2 = TWO POLE 3 = THREE-WAY 4 = FOUR-WAY D = DIMMER F = FAN SPEED CONTROL FH = FRACTIONAL HORSEPOWER MANUAL CONTROLLER IH = INTEGRAL HORSEPOWER MANUAL CONTROLLER K = KEYED LV# = LOW VOLTAGE / DIGITAL M = MANUAL MOTOR STARTER DISCONNECT OS# = OCCUPANCY SENSOR P = SPST PILOT LIGHT WP = WEATHER PROOF # = REFER TO LIGHTING CONTROL DEVICE SCHEDULE AUTOMATIC LOAD CONTROL RELAY BRANCH CIRCUIT TRANSFER SWITCH CEILING / WALL MOUNTED OCCUPANCY SENSOR (# INDICATES TYPE PER SCHEDULE) CORNER 90 DEGREE SENSING ONE-DIRECTION SENSING, CEILING/WALL MOUNT CEILING MOUNT, TWO-DIRECTION SENSING CEILING MOUNT, FOUR-DIRECTION SENSING CONTACTOR (SIZE, COIL VOLTAGE AND NUMBER OF POLES AS INDICATED) TRACK-MOUNTED CURRENT LIMITER (## INDICATES AMPERAGE) DAYLIGHT SENSOR (# INDICATES TYPE PER SCHEDULE) LIGHTING CONTROLS PROCESSOR AND/OR EQUIPMENT POWER PACK (# INDICATES TYPE PER SCHEDULE) PHOTOELECTRIC SWITCH ROOM CONTROLLER (# INDICATES TYPE PER SCHEDULE) TIME SWITCH ALC BTS #### R## C# LC CL## P# D# OR IG JJ *SYMBOL DEMONSTRATED WITH DUPLEX RECEPTACLE, WHEN USED IN COMBINATION WITH OTHER DEVICES MEANING IS SIMILAR FOR THOSE DEVICE TYPES. REFER TO LIGHTING CONTROL DEVICE SCHEDULE FOR MORE INFORMATION. PS# TS# GFR WH SPD 15 METER UTILITY D M VS VM AM AS KK# ### ST PFR AM DIGITAL VM ELECTRICAL ONE-LINE & RISER DIAGRAM MDP ELEC ROOM ### AMPS 480Y/277V 3Ø 4W SWITCHBOARD ## KW GENERATOR 480Y/277V, 3Ø, 4W ##A, 3P M/G ATS# ##A ATS# (W/BYPASS) ##A TX# TX# SWITCH (RATING AS INDICATED) DRAWOUT CIRCUIT BREAKER (RATINGS AS INDICATED) FUSED SWITCH (RATING, POLES AND FUSE TYPE AS INDICATED) COMBINATION FUSED SWITCH/STARTER AND STARTER SIZE CIRCUIT BREAKER (RATINGS AS INDICATED) COMBINATION CIRCUIT BREAKER/STARTER AND STARTER SIZE PANELBOARD, SINGLE OR MULTI-SECTION (REFER TO SCHEDULES) ISOLATED POWER PANELBOARD W/ INTEGRAL TRANSFORMER (REFER TO SCHEDULES) TRANSFORMER (TYPE AND RATINGS AS INDICATED) SHIELDED TRANSFORMER (TYPE AND RATINGS AS INDICATED) AUTOMATIC TRANSFER SWITCH (RATINGS AS INDICATED) AUTOMATIC TRANSFER SWITCH WITH BYPASS (RATINGS AS INDICATED) GENERATOR (RATINGS AS INDICATED) INDICATES CONNECTION TO GROUNDING ELECTRODE SYSTEM IF GENERATOR IS CONNECTED AS A SEPARATELY DERIVED SOURCE SWITCHGEAR, SWITCHBOARD AND/OR DISTRIBUTION PANELBOARD (TYPE, RATING, DEVICES AND ACCESSORIES AS INDICATED) COMBINATION DIGITAL VOLT METER/AMMETER CIRCUIT IDENTIFICATION (REFER TO CIRCUIT SCHEDULE) GROUND FAULT RELAY PHASE FAILURE RELAY KIRK-KEY INTERLOCK (# INDICATES KEY PAIR) SHUNT TRIP AMMETER (RANGE AS SPECIFIED OR REQUIRED) VOLTMETER (RANGE AS SPECIFIED OR REQUIRED) UTILITY METER (AS REQUIRED BY UTILITY) AMMETER SWITCH VOLTMETER SWITCH WATT-HOUR METER, "D" DENOTES DEMAND REGISTER, "15" DENOTES MINUTES OF DEMAND INTERVAL CURRENT TRANSFORMER RATING AS SPECIFIED OR REQUIRED POTENTIAL TRANSFORMER RATING AS SPECIFIED OR REQUIRED SURGE-PROTECTIVE DEVICE GROUND CONNECTION GROUND CONNECTION WITH TEST WELL GROUND ROD LIGHTNING ARRESTER CAPACITOR CONTACT (OPEN OR CLOSED) HEATER MOTOR BLOCK LOAD KW OR KVA FAULT POINT REFERENCED IN SHORT CIRCUIT CURRENT AND VOLTAGE DROP SPREADSHEETF#FP# ##A 3P ##A 3P ##AS 3P ##AF ##AS 3P ##AF FUSE TYPE NEMA # ##A 3P ##A 3P NEMA # HP ## CALL OUTS ENLARGED PLAN CALLOUT NOT IN SCOPE POLE T2 POLE T1 POLE T3 POLE T4 POLE P9 POLE P10 POLE P8 POLE P7 POLE P11 POLE P12 POLE A2 POLE A1 POLE P1 POLE P2 POLE P4 POLE P3POLE P5POLE P6 45 53 50 47 49 48 45 46 43 47 55 51 53 60 56 58 57 55 56 57 58 56 59 56 54 53 58 57 57 55 56 57 57 57 54 55 42 48 52 54 53 53 53 53 54 53 48 45 45 48 53 54 53 53 53 53 54 52 48 42 55 54 57 57 57 56 55 57 57 58 53 54 56 59 56 58 57 56 55 58 58 56 60 53 51 55 48 43 46 45 48 49 48 50 53 45 45 53 50 47 49 48 45 46 43 47 55 51 53 60 56 58 57 55 56 57 58 56 59 56 54 53 58 57 57 55 56 57 57 57 54 55 42 48 52 54 53 53 53 53 54 53 47 45 45 48 53 54 53 53 53 53 54 52 48 42 55 54 57 57 57 56 55 57 57 58 53 54 56 59 56 58 57 56 55 57 58 56 60 53 51 55 48 43 46 45 48 49 48 50 53 46 44 53 50 47 49 48 45 46 42 47 55 51 52 60 56 58 58 55 55 57 57 56 60 57 53 53 58 57 57 55 56 57 57 57 54 56 42 48 52 54 54 53 53 53 54 53 47 45 45 48 53 54 53 53 53 53 54 53 47 42 54 54 57 56 57 56 54 57 57 58 53 54 55 59 56 58 57 56 55 57 57 56 60 54 50 56 48 43 46 46 48 49 47 50 53 46 81 89 84 93 102 102 98 96 87 82 96 90 100 113 109 110 108 103 105 107 111 109 111 106 108 104 115 110 105 99 100 106 107 112 106 109 90 100 109 110 101 99 99 98 105 106 97 89 93 101 109 107 99 99 98 100 107 105 96 85 112 107 113 108 106 100 99 105 109 114 103 105 106 114 110 111 107 105 103 107 110 109 110 99 90 91 81 85 96 97 104 102 97 84 93 82 44 53 50 47 49 48 45 46 42 47 55 51 53 60 56 58 57 55 55 57 58 56 59 56 53 53 58 57 57 55 56 57 57 57 54 55 42 48 52 54 54 53 53 53 54 53 47 45 45 48 53 53 53 53 53 53 54 52 47 42 55 54 57 56 57 56 54 57 57 58 53 54 56 59 56 58 57 56 55 57 57 56 60 53 51 56 48 43 46 46 48 50 48 50 53 46 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00000000000000 0 0 0 0 0 0 0 0000000000000000000000000000000 0 0 0 0 0 0 0 0000 0 0 0 0 0 0 0 0 0 0 0 0 0 © 2022 GENERATOR STUDIO LLC ISSUE DATE: PROJECT NO. DRAWN BY: CHK'D BY: SHEET TITLE 1 SEAL D 2345 C B A SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM OWNER GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM ARCHITECT ARCHITECT: LICENSE NO. MICHAEL J. KRESS 12779 D.A. HOGAN & ASSOCIATES, INC. 119 1ST AVENUE SOUTH, SUITE 110 SEATTLE, WA 98104 206.285.0400 DAHOGAN.COM LANDSCAPE ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM STRUCTURAL & CIVIL ENGINEER HENDERSON ENGINEERS 8345 LENEXA DRIVE, #300 LENEXA, KS 66214 816.663.8700 HENDERSONENGINEERS.COM MEP ENGINEER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM DEVELOPER 4/4/2022 5:40:59 PM 21032 SEATTLE SOUNDERS FC HEADQUARTERS & TRAINING CENTER 04.27.2022 Author 1901 OAKESDALE AVENUE SW RENTON, WA 98057 Checker REV DESCRIPTION DATE TEL FAX WWW.HENDERSONENGINEERS.COM 2150004931 WA. CORPORATE NUMBER: 1754 06/30/22 8345 LENEXA DRIVE, SUITE 300 LENEXA, KS 66214 913.742.5000 913.742.5001 THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF IT IS NOT TO BE USED FOR PURPOSES. LICENSE #LICENSE #LICENSE # ANDRIA J. ODROWSKI 56705 CONSTRUCTION PRELIMINARY SUBMITTAL E100 ELECTRICAL LIGHTING PLAN NTS ELECTRICAL PLAN1 N