Loading...
HomeMy WebLinkAboutMFP22003766.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP22003766 IVR Number: 22003766 Permit Information Permit Name: Comcast Cable Franchise Permit (JB-1000498) Address/Location:07/19/2022Application Date:3223059063Parcel Number: 17615 108TH AVE SE Permit Type:10/21/2022Issue Date:Franchise Permit Work Class:10/23/2023Expiration Date:Minor Utility Job Number: JB0001000498Franchise Type:Cable Description: Comcast (JB 1000498) Comcast to access existing vault in the landscape strip along the south side of SE Carr Rd. Proof existing conduit and pull 25' of 96ct fiber to riser pole. Overlash 304' of 96ct fiber along the south side of SE Carr Rd. Pull new fiber 12' in ROW and continue toward 17615 108th Ave SE. RESTORATION PER CITY OF RENTON STANDARDS. Contacts Name Address PhoneTypeBilling Andrew Parker Comcast 410 Valley Ave NW, Suite 12 Bldg C Puyallup, WA 98371 B: (253) 225-0596Applicant Joshua Day CCI SYSTEMS 105 Kent St Iron Mountain, MI 49801 ApplicantX Rhonda Resnik Comcast 410 Valley Ave NW, Suite 12, Bldg C Puyallup, WA 98371 B: (253) 864-4246Applicant Corrie Lamb Comcast 2525 Beaufort Dr. Modesto, CA 95355 Applicant Tom Donnelly Comcast Business Communications 1701 Jfk Blvd, 32nd Floor Philadelphia, PA 19103 B: (215) 286-7347 C: (215) 286-7557 Contact David Standring Cannon Construction LLC 406 Porter Way Milton, WA 98354 Contractor Business License Number: 20838Construction Contractor: CANNOCL791JK Electrical Contractor: CANNOCI873CL CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner Laurie Dietz Comcast - Billing 1701 John F. Kennedy Blvd. Philadelphia, PA 19103 H: (425) 741-5733Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 of 1 | Published: 1/2/2019 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 1/2/2019 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Site Specific Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $630.00. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐New Construction ☐Repair/Relocate ☐Underground ☐Overhead ☐Sidewalk ☐Street ☐Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Comcast Cable Communications Management (253) 225-0596 Andrew Parker Cannon Construction LLC - 253-922-2787 20838601590363 JB0001000498 Andrew_Parker2@comcast.com F61436-JB-1000498-RENTON-117615 108th Ave SE, Renton, WA 98055. The proposed work within the ROW is to access existing Comcast vault in landscape along south side of SE x 7/19/22 CARR RD; proof existing conduit and pull new 25' of 96ct fiber to riser pole; overlash approx 304' of 96ct fiber to existing Comcast strand two spans along south side of SE CARR RD, proof existing riser/buried conduit, pull new fiber 12' in ROW and continuing toward address 17615 108th Ave SE, Renton, WA 98055. No disturbance of surface. x MFP22003766 Scott Warlick RESTORATION PER CITY OF RENTON STANDARDS10/21/2022 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering 425.941.7820 Milton,WA 98354406 Porter Way Nate Pinson x x Project Name: F61436-JB-1000498-RENTON-1 Permit #: Site Address: 17615 108th Ave SE, Renton, WA 98055. Work Date: From 08/22/2022 To 08/25/2022 Work Time: Start ____9AM__________ End ____3PM__________ Construction Company: Cannon Construction LLC The proposed work within the ROW is to access existing Comcast vault in landscape along south side of SE CARR RD; proof existing conduit and pull new 25' of 96ct fiber to riser pole; overlash approx 304' of 96ct fiber to existing Comcast strand two spans along south sid of SE CARR RD, proof existing riser/buried conduit, pull new fiber 12' in ROW and continuing toward address 17615 108th Ave SE, Renton, WA 98055. No disturbance of surface. MFP22003766 Monday - Friday Scott Warlick CED 10/21/2022 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) 7/19/22 Andrew Parker DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION SHEET INDEX: C1 - OVERVIEW MAP C2 - LEGEND TCPG - TCP SPECS & GENERAL NOTES PS - PROJECT SHEETS 1000498 MSJD07/19/2022 PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437 CHRIS.ATKINSON@CABLECOMLLC.NET C1 PROJECT DESCRIPTION: The proposed work within the ROW is to access existing Comcast vault in landscape along south side of SE CARR RD; proof existing conduit and pull new 25' of 96ct fiber to riser pole; overlash approx 304' of 96ct fiber to existing Comcast strand two spans along south sid of SE CARR RD, proof existing riser/buried conduit, pull new fiber 12' in ROW and continuing toward address 17615 108th Ave SE, Renton, WA 98055.No disturbance of surface. BEGIN ROW WORK: 47.44496, -122.19894 END ROW WORK: 47.44515, -122.19766 1 2 3 MFP22003766 LINETYPES RISER POLE POLE ANCHOR/DOWN GUY STREET LIGHT MISC. UTILITY UTILITY POLE GROUND/BOND FIRE HYDRANT CULVERT WING WALL BRIDGE MANHOLE PULL-BOX VAULT/BUILDING STORAGE COIL AERIAL STORAGE A A AERIAL FIBER - EXISTING STRAND - EXISTING INNERDUCT - EXISTING UG FIBER - EXISTING CONDUIT - EXISTING UG FIBER - PROPOSED AERIAL FIBER - PROPOSED STRAND - PROPOSED CONDUIT - PROPOSED INNERDUCT - PROPOSED B B B B B B B B UNK UNK UNKNOWN UTILITY EOP EOP EOP RIGHT OF WAY EDGE OF PAVEMENT U R 0' 0' STREET SIGN - NO POWER STREET SIGN - w/ POWER TRAFFIC LIGHT PERMANENT SIGNS CONCRETE BOLLARD GATE ARMS ROAD YELLOW LINES ROAD WHITE LINES PARKING LINES RAILROAD SIDEWALK SIDEWALK HATCH - CONCRETE SIDEWALK HATCH - ASPHALT OVERHEAD CABLE GUARDRAIL P/L P/L P/L PROPERTY LINE EASEMENT HANDICAP PARKING - PAINT R/W R/W A A A A SYMBOLS TRENCH INSTALLATION G G W W T T E E SEW SEW SD SD X X X TV TV GAS WATER TELEPHONE ELECTRIC SANITARY SEWER (SEW) STORM DRAIN FENCE CABLE TV VAULT/PROPOSED VAULTVV 3'x5' BORE PIT 8" POTHOLE DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/2022 PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems C2 MFP22003766 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/20221" = 40' PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023 joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437CHRIS.ATKINSON@CABLECOMLLC.NET 1 PCMS RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' 45 / 55 MPHRURAL ROADS 500' 25 / 30 MPH 200' (2) URBAN STREETS 25 MPH OR LESS 100' (2) 10 550 605 660 105 125 150 205 270 165 225 295 180 245 320 540 115 - - -- - 720 660 780 840 25 30 35 40 45 50 55 10' 60 40 40 65 70 SHOULDERWIDTH(feet) Posted Speed (mph) 160 200 220 170 190 240 150 190 130 170 120 150 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) 40 60 60 90 90 90 2 60 / 65 MPHRURAL HIGHWAYS FREEWAYS & EXPRESSWAYS SIGN SPACING = X (1) 25 30 35 40 50 55 12 60 11 65 70 MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANEWIDTH(feet) Posted Speed (mph) 8' 55 / 70 MPH 800' 1 MILE AHEAD 2.0 SEC 2.0 SEC MPH 50/70 35/45 25/30 TAPER TANGENT 40 30 20 80 60 40 CHANNELIZATION DEVICE SPACING (feet) RURAL ROADS & URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. 500 550 600 495 450 45 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. RIGHT LANE CLOSURE FIELD LOCATE 1 MILE  IN ADVANCE OF LANE CLOSURE SIGNING. LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 LENGTH (feet)250 305 360 425 495 570 645 730 BUFFER DATA 155 200 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R 150'100'172'123'100' HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HOST VEHICLE WEIGHT > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 74' WORKZONE TRAFFIC CONTROL GENERAL INFO PCMS TM A SEQUENTIAL ARROW SIGN TRANSPORTABLE ATTENUATOR PORTABLE CHANGEABLE MESSAGE SIGN VERY SHORT DURRATION INTERSECTION CROSSING PRPOTECTIVE VEHICLE VERY SHORT DURRATION INTERSECTION CROSSING FLAGGING STATION LEGEND FLAGGING STATION TEMPORARY SIGN LOCATION CHANNELIZING DEVICES PROTECTIVE VEHICLE SPOTTER STATION GENERAL NOTES: 1. FLAGGERS SHALL BE USED IN ACCORDANCE WITH WAC 468-950302. 2. PRIORITY PASSAGE THROUGH WORK AREA FOR EMERGENCY VEHICLES SHALL BE PROVIDED AT ALL TIMES. 3. ALL SIGNS, CHANNELIZED DEVICES AND SPACING SHALL CONFORM TO THE MUTCD. 4. CHANNELIZATION DEVICES ARE 28" REFLECTIVE CONES (SEE TABLE FOR SPACING DISTANCES) 5. ALL SPACING MUST ACCOMMODATE AT-GRADE INTERSECTION AND/OR DRIVEWAYS. 6. MAINTAIN 4' MINIMUM SIDEWALK WIDTHS. 7. MAINTAIN 11' VEHICLE TRAVEL LANE WIDTHS. 8. SPACING MAY BE REDUCED IN URBAN AREA TO FIT CONDITIONS. 9. SPOTTER TO ASSISTS PEDESTRIANS AROUND WORK ZONE. 10. SPACING MAY BE REDUCED IN URBAN AREA TO FIT CONDITIONS. 11. UNIFORMED POLICE OFFICER REQUIRED ON SITE WHEN WORKING WITHIN 150' OF A SIGNALIZED INTERSECTION. NEW TRAFFIC FLOW UNIFORM POLICE OFFICER TCPG > MFP22003766 292305919810712 SE CARR RD BEGIN ROW WORK: 47.44496, -122.19894 EOPEOPEOPEO PEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPP/ L P/ L P/ L P/ L P/L P/LP/LP/LP/LP/LP/LP/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/ L P/ L P/ L P/L P/L P/L P/L P/L P/L P/L P/L P/ L P/L P/L P/L P/L P/L P/L P/LR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/ W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE CARR RD 1 06 T H P L S E PRIVATE DR IVE 292305915810622 SE CARR RD 3223059063 17605 108TH AVE SE 45'57'95'EXIT ROW :47.44515, -122.19766 WOR K A R E A WORK AREA WORK AR E A 10 550 605 660 105 125 150 205 270 165 225 295 180 245 320 540 115 - - -- - 720 660 780 840 25 30 35 40 45 50 55 10' 60 40 40 65 70 SHOULDERWIDTH(feet) Posted Speed (mph) 160 200 220 170 190 240 150 190 130 170 120 150 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) 40 60 60 90 90 90 25 30 35 40 50 55 12 60 11 65 70 MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANEWIDTH(feet) Posted Speed (mph) 8' 500 550 600 495 450 45 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 LENGTH (feet)250 305 360 425 495 570 645 730 BUFFER DATA 155 200 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R 150'100'172'123'100' HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HOST VEHICLE WEIGHT > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 74' SINGLE PHASE TCP FOR ROW WORK RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' 45 / 55 MPHRURAL ROADS 500' 25 / 30 MPH 200' (2) URBAN STREETS 25 MPH OR LESS 100' (2) 60 / 65 MPHRURAL HIGHWAYS FREEWAYS & EXPRESSWAYS SIGN SPACING = X (1) 55 / 70 MPH 800' MPH 50/70 35/45 25/30 TAPER TANGENT 40 30 20 80 60 40 CHANNELIZATION DEVICE SPACING (feet) RURAL ROADS & URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. SPOTTER TO ASSIST PEDESTRIANS THROUGH WORK ZONE ROADWORK W21-4 AHEAD ROADWORK W21-4 AHEAD X X CLOSEDRIGHT LANE W20-5R AHEAD W1-4L ROADWORK W21-4 AHEAD X X X CLOSE LANE AS IT FORMS OK 5' MINSTAND SPEED LIMIT25 SPEED LIMIT35 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/20221" = 40' PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023 joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437CHRIS.ATKINSON@CABLECOMLLC.NET PS-1MATCH TO PS-2MFP22003766 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/20221" = 40' PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023 joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437CHRIS.ATKINSON@CABLECOMLLC.NET EO P EO P EOP EOP EO P EOP EOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPEOPP/ L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/ L P/L P/L P/L P/LP/L P/L P/L P/L P/L P/L P/L P/L P/ L P/L P/ L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/ L P/L P/L P/L P/L P/L P/ L P/ L P/L P/L P/L P/L P/L P/L P/L P/ L P/ L P/L P/ L P/ L P/ L P/L P/L P/L P/L P/L P/ L P/L P/ L P/L P/L P/L P/L P/L P/ L P/ L P/ L P/ L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/LP/ L P/ L P/ L R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/W R/ W R/ W R/W R/W R/ W R/W R/W R/W R/ W R/ W R/WR/WR/ W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/ W R/ W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE CAR R R D 105TH PL SE 322305906317605 108TH AVE SE 3223059237 10545 SE CARR RD 322305929910433 SE CARR RD 322305904010436 SE CARR RD 322305905310500 SE CARR RD 292305915110415 SE 174TH ST 1 0 0 ' 4 5 ' 60' 34' 10 550 605 660 105 125 150 205 270 165 225 295 180 245 320 540 115 - - -- - 720 660 780 840 25 30 35 40 45 50 55 10' 60 40 40 65 70 SHOULDERWIDTH(feet) Posted Speed (mph) 160 200 220 170 190 240 150 190 130 170 120 150 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) 40 60 60 90 90 90 25 30 35 40 50 55 12 60 11 65 70 MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANEWIDTH(feet) Posted Speed (mph) 8' 500 550 600 495 450 45 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 LENGTH (feet)250 305 360 425 495 570 645 730 BUFFER DATA 155 200 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R 150'100'172'123'100' HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HOST VEHICLE WEIGHT > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 74' SINGLE PHASE TCP FOR ROW WORK RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' 45 / 55 MPHRURAL ROADS 500' 25 / 30 MPH 200' (2) URBAN STREETS 25 MPH OR LESS 100' (2) 60 / 65 MPHRURAL HIGHWAYS FREEWAYS & EXPRESSWAYS SIGN SPACING = X (1) 55 / 70 MPH 800' MPH 50/70 35/45 25/30 TAPER TANGENT 4030 20 80 6040 CHANNELIZATION DEVICE SPACING (feet) RURAL ROADS & URBAN ARTERIALS RESIDENTIAL & BUSINESS DISTRICTS 1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. ROADWORK W21-4 AHEAD X SPEED LIMIT35 SPEEDLIMIT25 PS-2MATCH TO PS-1MATCH TO PS-3MFP22003766 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/20221" = 40' PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E TRAFFIC CONTROL SUPERVISOR: JOSH DAYTCS CERT # 012056 EXP: 1/31/2023 joshua.day@ccisystems.com CONTRACTOR: CABLECOM LLC1316 BONNEVILLE AVE BLDG A,SNOHOMISH WA 98290PHONE: 360-926-3437 TRAFFIC CONTROL 24-HR CONTACT: CHRIS ATKINSONMOBILE: 360-926-3437CHRIS.ATKINSON@CABLECOMLLC.NET EO P EO P EOPEOPP/ L P/ L P/ L P/L P/L P/ L P/ L P/ L P/ L P/ L P/ L P/L P/ L P/L P/L P/L P/L P/L P/L P/ L P/ L P/ L P/ L P/ L P/ L P/ L P/ L P/ L P/L P/L P/L P/L P/L P/ L P/ L P/ L P/ L P/L P/L P/L P/L P/L P/L P/L P/L P/ L P/ L P/L P/L P/L P/L P/L P/L P/L P/L P/ L P/ L P/ L P/ L P/ L P/ L P/ L P/ L P/ L P/ L P/ L P/L P/L P/L P/ L P/ L P/ L P/ L P/ L R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/ W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W10 0 ' 4 5 ' EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P EO P 322305929910433 SE CARR RD 322305915417735 105TH PL SE 322305936118102 107TH PL SE 3223059155 3223059316 322305904010436 SE CARR RD SE CARR RD 100 ' 45' 10 550 605 660 105 125 150 205 270 165 225 295 180 245 320 540 115 - - -- - 720 660 780 840 25 30 35 40 45 50 55 10' 60 40 40 65 70 SHOULDERWIDTH(feet) Posted Speed (mph) 160 200 220 170 190 240 150 190 130 170 120 150 MINIMUM SHOULDER TAPER LENGTH = L/3 (feet) 40 60 60 90 90 90 25 30 35 40 50 55 12 60 11 65 70 MINIMUM LANE CLOSURE TAPER LENGTH = L (feet) LANEWIDTH(feet) Posted Speed (mph) 8' 500 550 600 495 450 45 USE A MINIMUM 3 DEVICES TAPER FOR SHOULDER LESS THEN 8'. LONGITUDINAL BUFFER SPACE = B SPEED (MPH)25 30 35 40 45 50 55 60 65 70 LENGTH (feet)250 305 360 425 495 570 645 730 BUFFER DATA 155 200 TRANSPORTABLE ATTENUATOR ROLL AHEAD DISTANCE = R 150'100'172'123'100' HOST VEHICLE WEIGHT 9,900 TO 22,000 lbs. HOST VEHICLE WEIGHT > 22,000 lbs. < 45 MPH 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 74' SINGLE PHASE TCP FOR ROW WORK RURAL ROADS & URBAN ARTERIALS 35 / 40 MPH 350' 45 / 55 MPHRURAL ROADS 500' 25 / 30 MPH 200' (2) URBAN STREETS 25 MPH OR LESS 100' (2) 60 / 65 MPHRURAL HIGHWAYS FREEWAYS & EXPRESSWAYS SIGN SPACING = X (1) 55 / 70 MPH 800' MPH 50/70 35/45 25/30 TAPER TANGENT 40 3020 8060 40 CHANNELIZATION DEVICE SPACING (feet) RURAL ROADS & URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS 1500' (1) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE RAMPS, AT-GRADE INTERSECTIONS AND DRIVEWAYS.(2) THIS SPACING MAY BE REDUCED IN URBAN AREAS TO FIT ROADWAY CONDITIONS. ROADWORK W21-4 AHEAD W4-2r CLOSED RIGHT LANE W20-5R AHEAD X X X SPEEDLIMIT35PS-3MATCH TO PS-2MFP22003766 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION SHEET INDEX: C1 - OVERVIEW MAP C2 - LEGEND C3 - GENERAL NOTES PS - PROJECT SHEETS 1000498 MSJD07/19/2022 PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E C1 PROJECT DESCRIPTION: The proposed work within the ROW is to access existing Comcast vault in landscape along south side of SE CARR RD; proof existing conduit and pull new 25' of 96ct fiber to riser pole; overlash approx 304' of 96ct fiber to existing Comcast strand two spans along south side of SE CARR RD, proof existing riser/buried conduit, pull new fiber 12' in ROW and continuing toward address 17615 108th Ave S E, Renton, WA 98055.Nodisturbanceofsurface. BEGIN ROW WORK: 47.44496, -122.19894 END ROW WORK: 47.44515, -122.19766 1 MFP22003766 LINETYPES RISER POLE POLE ANCHOR/DOWN GUY STREET LIGHT MISC. UTILITY UTILITY POLE GROUND/BOND FIRE HYDRANT CULVERT WING WALL BRIDGE MANHOLE PULL-BOX VAULT/BUILDING STORAGE COIL AERIAL STORAGE A A AERIAL FIBER - EXISTING STRAND - EXISTING INNERDUCT - EXISTING UG FIBER - EXISTING CONDUIT - EXISTING UG FIBER - PROPOSED AERIAL FIBER - PROPOSED STRAND - PROPOSED CONDUIT - PROPOSED INNERDUCT - PROPOSED B B B B B B B B UNK UNK UNKNOWN UTILITY EOP EOP EOP RIGHT OF WAY EDGE OF PAVEMENT U R 0' 0' STREET SIGN - NO POWER STREET SIGN - w/ POWER TRAFFIC LIGHT PERMANENT SIGNS CONCRETE BOLLARD GATE ARMS ROAD YELLOW LINES ROAD WHITE LINES PARKING LINES RAILROAD SIDEWALK SIDEWALK HATCH - CONCRETE SIDEWALK HATCH - ASPHALT OVERHEAD CABLE GUARDRAIL P/L P/L P/L PROPERTY LINE EASEMENT HANDICAP PARKING - PAINT R/W R/W A A A A SYMBOLS TRENCH INSTALLATION G G W W T T E E SEW SEW SD SD X X X TV TV GAS WATER TELEPHONE ELECTRIC SANITARY SEWER (SEW) STORM DRAIN FENCE CABLE TV VAULT/PROPOSED VAULTVV 3'x5' BORE PIT 8" POTHOLE DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/2022 PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems C2 MFP22003766 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/2022 PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems GENERAL NOTES: 1.ALL VAULTS / HANDHOLES TO BE EQUIPPED WITH SECURITY LIDS WITHLOCKING BOLTS. 2.GROUND RESTORATION/RIGHT-OF-WAY SHALL BE RESTORED TO ORIGINALOR BETTER CONDITION..3.ALL 90 DEGREE BENDS IN CONDUIT CONSTRUCTION WILL BE A MINIMUM OF36" RADIUS UNLESS SPECIFIED OTHERWISE. 4.BURIED FIBER OPTIC WARNING SIGNS SHALL BE PLACED AT EACH SIDE OFALL ROAD CROSSINGS, AT CULVERTS, DITCHES AND IN A STRAIGHT LINE OFSIGHT SPACING OF APPROXIMATELY 500 FEET. 5.DEVIATIONS FROM THE ENGINEERED ROUTE REQUIRES A PROJECTMANAGER AND RIGHT-OF-WAY OWNER OR CARETAKER APPROVAL PRIOR TOCONSTRUCTION. 6.WHERE PERMITS FROM STATE, COUNTY, CITY, RAILROAD OR GOVERNMENTAGENCIES ARE REQUIRED, ALL WORK PERFORMED WILL COMPLY WITHTHESE AGENCIES STANDARD SPECIFICATIONS. 7.THE PROJECT MANAGER WILL NOTIFY BUILDING MANAGEMENT WHEN WORKWILL BEGIN ON BUILDING. CONTRACTOR TO COORDINATE ROOM ACCESSAND WORK START AND STOP TIMES WITH BUILDING MANAGEMENT. 8.THE PROJECT MANAGER IS TO BE NOTIFIED BY THE CONTRACTOR 24 HOURSPRIOR TO CONSTRUCTION. SEE COMPANY CONTACT LIST FOR CONTACTNAME(s) AND TELEPHONE NUMBER(s). 9.THE PROJECT MANAGER WILL RESERVE THE RIGHT TO INSPECT AT ANY TIMETHE WORK BEING PERFORMED BY THE CONTRACTOR. IF PROJECT MANAGERDETERMINES THAT THE WORK IS NOT BEING PERFORMED TO MINIMUMQUALITY STANDARDS, THEN THE CONTRACTOR SHALL PROVIDE REWORK ATHIS OWN COST. 10.ANY CHANGE IN PROJECT SCOPE, INCLUDING BUT NOT LIMITED TO, CONDUITLENGTH, CONDUIT PATH, AERIAL PATH ETC., MUST BE APPROVED BY THEPROJECT MANAGER. 11.ALL CORING/CONSTRUCTION THAT WILL CAUSE NOISE AND/OR VIBRATIONSHALL BE DONE WITHIN ALLOWED (9AM-3PM) BUSINESS HOURS. 12.ANY AND ALL UNDERGROUND UTILITIES ENCOUNTERED ARE THERESPONSIBILITY OF THE CONTRACTOR TO LOCATE, PROTECT, AND REPAIR,IF DAMAGED. 13.ALL FOOTAGES ARE BASED ON FIELD GATHERED MEASUREMENTS, AS SUCHSOME VARIANCE SHOULD BE ANTICIPATED. ADJUST AS NEEDED. 14.ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 36" MINIMUM COVER. SITEHAS POTENTIAL FOR ROCK THAT WOULD PREVENT THE ABILITY TO PROVIDETHE MINIMUM COVER. IN CASES WHERE THE MINIMUM COVER CAN NOT BEACHIEVED, THE CONDUIT SHALL BE PLACED IN A SCH 40 EMT SLEEVE ORAPPROVED EQUIVALENT. 15.WATER, SEWER, STORM SEWER AND EASEMENT LOCATIONS ARE BASED OFFOF CITY MAPS,NOT FIELD VERIFIED. 16.BORING OF AC PAVING IS REQUIRED AT ALL LOCATIONS AS INDICATED ONPLANS. 17.AT NO TIME SHALL CURBS, GUTTERS OR HANDICAP BE DISTURBED. 18.DOOR HANGERS ARE TO BE PLACED A MINIMUM OF 72 HOURS PRIOR TOSTART OF CONSTRUCTION WHEN APPLICABLE. 19.PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL PLACE MESSAGEBOARDS STATING LANE CLOSURES, AND DELAYS A WEEK IN ADVANCE.LOCATION OF THE MASSAGE BOARD SHALL BE COORDINATED WITH THE CITYINSPECTOR AT THE PRE-CONSTRUCTION MEETING. 20.LANE CLOSURES CANNOT EXCEED MORE THAN 300 FT. AT A TIME. FORSAFETY PURPOSES THERE SHALL BE ONLY ONE CLOSURE AT A TIME ALONGINTERNATIONAL BLVD. MORE FLAGGERS WILL BE NECESSARY TO HELPVEHICLES AND PEDESTRIANS IN THE WORK ZONES DURING THE LANECLOSURES. FIBER PLACEMENT NOTES: 1.CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES 48 HOURSPRIOR TO CONSTRUCTION ACTIVITY SEE LOCAL DIRECTORY FOR CONTACTTELEPHONE NUMBER OF LOCAL CALL BEFORE YOU DIG AGENCY. 2.CONTRACTOR SHALL RECORD SEQUENCE # OF FIBER CABLE AT EVERYWORK POLE, MANHOLE, FIBER STORAGE LOOP AND TAIL LOCATION.CONTRACTOR TO PROVIDE PROJECT MANAGER WITH SEQUENCE NUMBERSAT PROJECT COMPLETION. 3.SLACK LOOP AND SNOWSHOE STORAGE LOCATIONS SHALL BE DETERMINEDON CONSTRUCTION DRAWINGS, HOWEVER, REEL LENGTHS OF FIVEHUNDRED FEET (500') OR LESS ON LARGE COUNT FIBER OR THREE HUNDREDFEET (300') OR LESS ON SMALL COUNT FIBER ARE DIFFICULT TO USE ANDSHOULD BE PLACED AS FSL'S, NOT CUT AND RETURNED. 4.FIBER OPTIC IDENTIFICATION TAGS SHALL BE PLACED AT EVERY WORKPOLE, MANHOLE, FIBER, STORAGE LOOPS, SPLICE CASES AND WHEREINDICATED BY PROJECT MANAGER. TAGS NEED TO BE PLACED SO AS TO BEREAD FROM THE GROUND. 5.CABLE LUBRICATION SHALL BE USED TO REDUCE PULLING TENSION.LUBRICANTS MUST NOT CONTAIN ANY PETROLEUM PRODUCTS. 6.A 100 FOOT FIBER COIL MUST REMAIN IN ALL VAULTS UNLESS OTHERWISENOTED. 7.ALL BURIED INFRASTRUCTURE MUST BE ACCOMPANIED WITH WARNINGTAPE AND A TRACER WIRE, AT RISER POLES THE LOCATE WIRE SHALL BEACCESSIBLE AT THE BASE OF THE RISER. 8.ALL RISERS WILL BE CAPPED AT ALL TIMES. 9.ALL FIBER SHALL BE MARKED AS TO DIRECTION IN EACH VAULT.RED-NORTH, GREEN-SOUTH,YELLOW-EAST, AND BLUE-WEST. DO NOT TAPEFIBER CABLES TOGETHER IN RISER. DISCLAIMER: 1.IT IS THE RESPONSIBILITY OF THE CONSTRUCTION CONTRACTOR TO VERIFYALL RIGHT OF WAY BEFORE CONSTRUCTION IS TO BEGIN. NOUNDERGROUND INSTALLATION REPRESENTED WITHIN THESE PLAN SHEETSIS PROPOSED OUTSIDE OF THE RIGHT OF WAY. 2.THE UNDERGROUND ROUTE DEPICTED IS PRELIMINARY AND WILL/MAY VARYONCE UTILITIES HAVE BEEN FIELD LOCATED. 3.ANCHORING FOR THE AERIAL CONSTRUCTION IS TYPICALLY DETERMINEDDURING CONSTRUCTION AND IS COLLECTED IN THE AS-BUILT PHASE. C3 MFP22003766 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/20221" = 40' PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E 292305919810712 SE CARR RD PROOF EXISTING COMCAST CONDUIT; PULL (1) 96ct FOC (EXISTING CONDUIT PATH SHOWN APPROX.) BEGIN ROW WORK:47.44496, -122.19894CONTRACTOR TOACCESS EXISTINGCOMCAST VAULTEOPEOPEOP EO PEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPP/ L P/ L P/ L P/ L P/L P/LP/LP/LP/LP/LP/LP/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/ L P/ L P/ L P/L P/L P/L P/L P/L P/L P/L P/L P/ L P/L P/L P/L P/L P/L P/L P/LR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/ W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE CARR RD10 6 T H P L S E PRIVATE DR IVE 292305915810622 SE CARR RD 3223059063 17605 108TH AVE SE45'57'95'VB A A A A A A A A A OVERLASH (1) 96ct FOC TO EXISTING COMCAST STRAND 10' 10' 10' 15'27' 135'25'169' 12'BBEXIT ROW :47.44515, -122.19766 PS-1 MFP22003766 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/2022 PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems TYP MFP22003766 CCI Systems 105 Kent St Iron Mountain, MI 49801 July 19, 2022 To whom it may concern: City of Renton 1055 South Grady Way Renton, WA 98057 RE: Aerial Variance Request for JB #1000498 To whom it may concern, CCI Systems has been contracted to design and engineer this project on behalf of Comcast Cable Communications Management, LLC. Comcast is applying for a variance request in order to upgrade their existing facilities. Comcast proposes to overlash 96CT fiber ~304’. Comcast is requesting that the City of Renton approve this variance request based on the fact that the requirements for undergrounding this proposed over-lash will not cause substantial adverse impacts to other person or entities in the immediate area and will cause undue hardship. 1.Installation of undergrounding facilities will increase the total cost of construction roughly 15-25 times the amount of an aerial over-lash on the existing Comcast strand. 2.Potential damage to underground facilities will be increased. 3.Over-lash will not cause substantial adverse impact to other persons or entities in the immediate area. Over-lashing the cable will be accomplished in a few days, and the residents will not notice any impact. Comcast will clean up the over-lashed spans as necessary and identify and remove any existing dead cables along this route. 4.The variance is necessary to prevent and undue hardship due to the increased construction costs if forced to install the proposed extension underground. 5.The granting of the variance will not be materially detrimental to the public welfare because Comcast does agree to underground the cable system, but they are waiving the obligation into the future when all other utilities are underground to prevent an undue hardship against Comcast currently. Upon the granting of the Variance, Comcast will coordinate construction and traffic control as per your requirements. Comcast and their contractors want to cooperate at the highest level and agree to adhere to all provisions and requirements set forth by the City of Renton to insure safe installation and maintenance of the proposed facilities. MFP22003766 If you have any further questions regarding this project please contact Andrew Parker at 253-225-0593. Thank you for your consideration in this matter. Jennifer Ewing Fielding Project Coordinator CCI SYSTEMS o (906) 282-3618| e jennifer.ewing@ccisystems.com October 21, 2022 Jennifer Ewing CCI Systems. 105 Kent St, Iron Mountain, MI 49801 Via Email: Jennifer.ewing@ccisystems.com SUBJECT: Request for Undergrounding Exemption (JB#1000498, MFP22003766, 17615 108th Ave SE) Dear Mrs. Ewing: The City of Renton has reviewed your request to grant Comcast an exemption from Renton Municipal Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required to be installed underground, pursuant to the standards of the section of RMC. Comcast proposes to have Cannon Construction Inc overlash new 96CT fiber for a total of approximately 304 lineal feet to existing Puget Sound Energy (PSE) poles along SE Carr Rd within the City. See the enclosed Site Plan showing the proposed overlashing limits. ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. Ordinance 5720 grants Comcast, the right to install fiber optic cable and related appurtenances under, along, over, below, through and across the streets, avenues and alleys of City of Renton within the right-of-way of Renton. Section 3.4 of the franchise ordinance states that if all of the distribution lines all the wireline service providers, such as telecommunications service providers, as defined in RCW 35.99.010, a utility service provider or a Cable Operator (collectively “Service Providers”) in any portion of the Franchise Area are underground, Grantee shall place its Cable System’s distribution cables underground within that area; provided that such underground locations are actually capable of accommodating Grantee’s cable and other equipment without technical degradation of the Cable Systems’ signal quality. The proposal would utilize existing poles with other attached franchisee communication facilities and overlash to the existing Comcast aerial path. As minimum vertical height clearance of 15’-6” would need to be provided for, any existing obsolete cable will need to be removed; staff recommends these as conditions of approval. Therefore, the City is granting an exemption with conditions, per the Comcast franchise agreement which allows new overhead facilities to be placed overhead provided there are other similar providers overhead as well. Comcast is required to obtain all necessary private utility easements for work on private property. DECISION: The requested exemption from underground utility installation requirements RMC4-6-090 (C) as requested by the applicant is approved with conditions subject to the conditions below as the request complies with the Comcast Franchise Agreement. Comcast Job JB#1000498 Page 2 of 2 October 21, 2022 Conditions of Approval: 1. Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. 2. Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, November 4, 2022. Due to the ongoing state of emergency enacted by Governor’s Proclamation 20-28.14 (and as amended), the City Clerk’s Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub Monday through Friday. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted electronically. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. Sincerely, Brianne Bannwarth, PE Development Engineering Director cc: C.E. “Chip” Vincent, CED Administrator Justin Johnson, Construction Engineering Manager Scott Warlick, Engineering Specialist III Holly Powers, Engineering Specialist III Franchise Permits Enclosures: Site Plan DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION SHEET INDEX: C1 - OVERVIEW MAP C2 - LEGEND C3 - GENERAL NOTES PS - PROJECT SHEETS 1000498 MSJD07/19/2022 PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E C1 PROJECT DESCRIPTION: The proposed work within the ROW is to access existing Comcast vault in landscape along south side of SE CARR RD; proof existing conduit and pull new 25' of 96ct fiber to riser pole; overlash approx 304' of 96ct fiber to existing Comcast strand two spans along south side of SE CARR RD, proof existing riser/buried conduit, pull new fiber 12' in ROW and continuing toward address 17615 108th Ave S E, Renton, WA 98055.Nodisturbanceofsurface. BEGIN ROW WORK: 47.44496, -122.19894 END ROW WORK: 47.44515, -122.19766 1 MFP22003766 LINETYPES RISER POLE POLE ANCHOR/DOWN GUY STREET LIGHT MISC. UTILITY UTILITY POLE GROUND/BOND FIRE HYDRANT CULVERT WING WALL BRIDGE MANHOLE PULL-BOX VAULT/BUILDING STORAGE COIL AERIAL STORAGE A A AERIAL FIBER - EXISTING STRAND - EXISTING INNERDUCT - EXISTING UG FIBER - EXISTING CONDUIT - EXISTING UG FIBER - PROPOSED AERIAL FIBER - PROPOSED STRAND - PROPOSED CONDUIT - PROPOSED INNERDUCT - PROPOSED B B B B B B B B UNK UNK UNKNOWN UTILITY EOP EOP EOP RIGHT OF WAY EDGE OF PAVEMENT U R 0' 0' STREET SIGN - NO POWER STREET SIGN - w/ POWER TRAFFIC LIGHT PERMANENT SIGNS CONCRETE BOLLARD GATE ARMS ROAD YELLOW LINES ROAD WHITE LINES PARKING LINES RAILROAD SIDEWALK SIDEWALK HATCH - CONCRETE SIDEWALK HATCH - ASPHALT OVERHEAD CABLE GUARDRAIL P/L P/L P/L PROPERTY LINE EASEMENT HANDICAP PARKING - PAINT R/W R/W A A A A SYMBOLS TRENCH INSTALLATION G G W W T T E E SEW SEW SD SD X X X TV TV GAS WATER TELEPHONE ELECTRIC SANITARY SEWER (SEW) STORM DRAIN FENCE CABLE TV VAULT/PROPOSED VAULTVV 3'x5' BORE PIT 8" POTHOLE DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/2022 PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems C2 MFP22003766 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/2022 PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems GENERAL NOTES: 1.ALL VAULTS / HANDHOLES TO BE EQUIPPED WITH SECURITY LIDS WITHLOCKING BOLTS. 2.GROUND RESTORATION/RIGHT-OF-WAY SHALL BE RESTORED TO ORIGINALOR BETTER CONDITION..3.ALL 90 DEGREE BENDS IN CONDUIT CONSTRUCTION WILL BE A MINIMUM OF36" RADIUS UNLESS SPECIFIED OTHERWISE. 4.BURIED FIBER OPTIC WARNING SIGNS SHALL BE PLACED AT EACH SIDE OFALL ROAD CROSSINGS, AT CULVERTS, DITCHES AND IN A STRAIGHT LINE OFSIGHT SPACING OF APPROXIMATELY 500 FEET. 5.DEVIATIONS FROM THE ENGINEERED ROUTE REQUIRES A PROJECTMANAGER AND RIGHT-OF-WAY OWNER OR CARETAKER APPROVAL PRIOR TOCONSTRUCTION. 6.WHERE PERMITS FROM STATE, COUNTY, CITY, RAILROAD OR GOVERNMENTAGENCIES ARE REQUIRED, ALL WORK PERFORMED WILL COMPLY WITHTHESE AGENCIES STANDARD SPECIFICATIONS. 7.THE PROJECT MANAGER WILL NOTIFY BUILDING MANAGEMENT WHEN WORKWILL BEGIN ON BUILDING. CONTRACTOR TO COORDINATE ROOM ACCESSAND WORK START AND STOP TIMES WITH BUILDING MANAGEMENT. 8.THE PROJECT MANAGER IS TO BE NOTIFIED BY THE CONTRACTOR 24 HOURSPRIOR TO CONSTRUCTION. SEE COMPANY CONTACT LIST FOR CONTACTNAME(s) AND TELEPHONE NUMBER(s). 9.THE PROJECT MANAGER WILL RESERVE THE RIGHT TO INSPECT AT ANY TIMETHE WORK BEING PERFORMED BY THE CONTRACTOR. IF PROJECT MANAGERDETERMINES THAT THE WORK IS NOT BEING PERFORMED TO MINIMUMQUALITY STANDARDS, THEN THE CONTRACTOR SHALL PROVIDE REWORK ATHIS OWN COST. 10.ANY CHANGE IN PROJECT SCOPE, INCLUDING BUT NOT LIMITED TO, CONDUITLENGTH, CONDUIT PATH, AERIAL PATH ETC., MUST BE APPROVED BY THEPROJECT MANAGER. 11.ALL CORING/CONSTRUCTION THAT WILL CAUSE NOISE AND/OR VIBRATIONSHALL BE DONE WITHIN ALLOWED (9AM-3PM) BUSINESS HOURS. 12.ANY AND ALL UNDERGROUND UTILITIES ENCOUNTERED ARE THERESPONSIBILITY OF THE CONTRACTOR TO LOCATE, PROTECT, AND REPAIR,IF DAMAGED. 13.ALL FOOTAGES ARE BASED ON FIELD GATHERED MEASUREMENTS, AS SUCHSOME VARIANCE SHOULD BE ANTICIPATED. ADJUST AS NEEDED. 14.ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 36" MINIMUM COVER. SITEHAS POTENTIAL FOR ROCK THAT WOULD PREVENT THE ABILITY TO PROVIDETHE MINIMUM COVER. IN CASES WHERE THE MINIMUM COVER CAN NOT BEACHIEVED, THE CONDUIT SHALL BE PLACED IN A SCH 40 EMT SLEEVE ORAPPROVED EQUIVALENT. 15.WATER, SEWER, STORM SEWER AND EASEMENT LOCATIONS ARE BASED OFFOF CITY MAPS,NOT FIELD VERIFIED. 16.BORING OF AC PAVING IS REQUIRED AT ALL LOCATIONS AS INDICATED ONPLANS. 17.AT NO TIME SHALL CURBS, GUTTERS OR HANDICAP BE DISTURBED. 18.DOOR HANGERS ARE TO BE PLACED A MINIMUM OF 72 HOURS PRIOR TOSTART OF CONSTRUCTION WHEN APPLICABLE. 19.PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL PLACE MESSAGEBOARDS STATING LANE CLOSURES, AND DELAYS A WEEK IN ADVANCE.LOCATION OF THE MASSAGE BOARD SHALL BE COORDINATED WITH THE CITYINSPECTOR AT THE PRE-CONSTRUCTION MEETING. 20.LANE CLOSURES CANNOT EXCEED MORE THAN 300 FT. AT A TIME. FORSAFETY PURPOSES THERE SHALL BE ONLY ONE CLOSURE AT A TIME ALONGINTERNATIONAL BLVD. MORE FLAGGERS WILL BE NECESSARY TO HELPVEHICLES AND PEDESTRIANS IN THE WORK ZONES DURING THE LANECLOSURES. FIBER PLACEMENT NOTES: 1.CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES 48 HOURSPRIOR TO CONSTRUCTION ACTIVITY SEE LOCAL DIRECTORY FOR CONTACTTELEPHONE NUMBER OF LOCAL CALL BEFORE YOU DIG AGENCY. 2.CONTRACTOR SHALL RECORD SEQUENCE # OF FIBER CABLE AT EVERYWORK POLE, MANHOLE, FIBER STORAGE LOOP AND TAIL LOCATION.CONTRACTOR TO PROVIDE PROJECT MANAGER WITH SEQUENCE NUMBERSAT PROJECT COMPLETION. 3.SLACK LOOP AND SNOWSHOE STORAGE LOCATIONS SHALL BE DETERMINEDON CONSTRUCTION DRAWINGS, HOWEVER, REEL LENGTHS OF FIVEHUNDRED FEET (500') OR LESS ON LARGE COUNT FIBER OR THREE HUNDREDFEET (300') OR LESS ON SMALL COUNT FIBER ARE DIFFICULT TO USE ANDSHOULD BE PLACED AS FSL'S, NOT CUT AND RETURNED. 4.FIBER OPTIC IDENTIFICATION TAGS SHALL BE PLACED AT EVERY WORKPOLE, MANHOLE, FIBER, STORAGE LOOPS, SPLICE CASES AND WHEREINDICATED BY PROJECT MANAGER. TAGS NEED TO BE PLACED SO AS TO BEREAD FROM THE GROUND. 5.CABLE LUBRICATION SHALL BE USED TO REDUCE PULLING TENSION.LUBRICANTS MUST NOT CONTAIN ANY PETROLEUM PRODUCTS. 6.A 100 FOOT FIBER COIL MUST REMAIN IN ALL VAULTS UNLESS OTHERWISENOTED. 7.ALL BURIED INFRASTRUCTURE MUST BE ACCOMPANIED WITH WARNINGTAPE AND A TRACER WIRE, AT RISER POLES THE LOCATE WIRE SHALL BEACCESSIBLE AT THE BASE OF THE RISER. 8.ALL RISERS WILL BE CAPPED AT ALL TIMES. 9.ALL FIBER SHALL BE MARKED AS TO DIRECTION IN EACH VAULT.RED-NORTH, GREEN-SOUTH,YELLOW-EAST, AND BLUE-WEST. DO NOT TAPEFIBER CABLES TOGETHER IN RISER. DISCLAIMER: 1.IT IS THE RESPONSIBILITY OF THE CONSTRUCTION CONTRACTOR TO VERIFYALL RIGHT OF WAY BEFORE CONSTRUCTION IS TO BEGIN. NOUNDERGROUND INSTALLATION REPRESENTED WITHIN THESE PLAN SHEETSIS PROPOSED OUTSIDE OF THE RIGHT OF WAY. 2.THE UNDERGROUND ROUTE DEPICTED IS PRELIMINARY AND WILL/MAY VARYONCE UTILITIES HAVE BEEN FIELD LOCATED. 3.ANCHORING FOR THE AERIAL CONSTRUCTION IS TYPICALLY DETERMINEDDURING CONSTRUCTION AND IS COLLECTED IN THE AS-BUILT PHASE. C3 MFP22003766 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/20221" = 40' PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems S W N E 292305919810712 SE CARR RD PROOF EXISTING COMCAST CONDUIT; PULL (1) 96ct FOC (EXISTING CONDUIT PATH SHOWN APPROX.) BEGIN ROW WORK:47.44496, -122.19894CONTRACTOR TOACCESS EXISTINGCOMCAST VAULTEOPEOPEOP EO PEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPEOPEOPEOPEOPEOPEOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOPP/ L P/ L P/ L P/ L P/L P/LP/LP/LP/LP/LP/LP/L P/L P/L P/L P/L P/L P/L P/L P/L P/L P/ L P/ L P/ L P/L P/L P/L P/L P/L P/L P/L P/L P/ L P/L P/L P/L P/L P/L P/L P/LR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/ W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/W R/WR/W R/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSE CARR RD10 6 T H P L S E PRIVATE DR IVE 292305915810622 SE CARR RD 3223059063 17605 108TH AVE SE45'57'95'VB A A A A A A A A A OVERLASH (1) 96ct FOC TO EXISTING COMCAST STRAND 10' 10' 10' 15'27' 135'25'169' 12'BBEXIT ROW :47.44515, -122.19766 PS-1 MFP22003766 DATE:DESCRIPTION:REV:BY: Notes: REVISION:JOB TRACKER NO;SHEET NO: DRAWN:DATE:CHECKED: ADDRESS: SITE: STATUS: CONSTRUCTION SUPERVISOR:Casey Brown(425)-754-0064Casey_Brown2@comcast.com1525 75 St. SW #200Everett, WA 98203 CONFIDENTIAL & PROPRIETARY INFORMATION 1000498 MSJD07/19/2022 PROJECT FOR: RENTON WA 98055 17615 108TH AVE SE Boeing Employees Credit Union 906-282-3670Mike SnowdanPROJECT MANAGERCCI Systems TYP MFP22003766 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Conditions for Permit MFP22003766 Engineering 1 Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15'-6". 2 The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. 3 A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4 Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. Page 1 of 1