HomeMy WebLinkAboutBid DrawingsPH:
CITY OF RENTON
OWNER:
616 W PERIMETER RD, UNIT A
RENTON, WA 98057
(206) 200-6811
CONTACT: WILLIAM ADAMS
wadams@rentonwa.gov
PH:
JOHNSTON ARCHITECTS LLC
ARCHITECT:
100 NE NORTHLAKE WAY, SUITE 200
SEATTLE WA 98105
(206) 523-6150
CONTACT: GENEVIEVE THERIAULT
GTHERIAULT@JOHNSTONARCHITECTS.COM
PROJECT TEAM
PROJECT INFORMATION
OWNER CITY OF RENTON
PARCEL # 0723059007
LEGAL DESCRIPTION POR SECS 7 & 18-23-5 & POR TOBINS D C INCL POR
PLATTED & VAC STS LY WLY OF COMM W W # 2 N OF N LN DIXIE
AVE & ELY OF STATE HWAY # 5 & ELY & SLY OF FOLG LN BEG ON ELY MGN SD HWAY AT PT 5 FT
S OF N LN OF LOT 8 BLK 18 BRYN MAWR TH E 89.23 FT TH N 05-16-51 E 438.90 FT TH N 40-09-47 E
188.55 FT TH N 60 FT TH N 29-00-40 W 197.07 FT TH S 88-27-28 E 90.83 FT TH N 01-32-32 W 40 FT
TH S 88-27-28 E 234.53 FT TH S 35-00-00 E 142.41 FT TH E 403.70 FT LESS LOTS 19 TO 22 INCL BLK
4 RENTON REAL ESTATE COS 1ST ADD LESS PORTION FOR LANE HANGAR CONDOMINIUM -TGW
POR OF RAINIER AVE N PER RENTON VAC ORD #5780
PROJECT DESCRIPTION RENOVATION OF EXISTING 2,390 SF OFFICE BUILDING INCLUDING
NEW NON LOAD-BEARING INTERIOR PARTITIONS, NEW FINISHES,
NEW CASEWORK, REMODELED RESTROOMS, AND NEW ADA RAMPS
W P E R I M E T E R R D
AIRPORT WAYRAINIER AVE NRAINIER AVE SRENTON AVE SPRIMARY ENTRY
JURISDICTION CITY OF RENTON
ZONING CODE RENTON MUNICIPAL CODE
BUILDING CODE 2018 INTERNATIONAL BUILDING CODE
OTHER RELEVANT CODES 2018 WASHINGTON STATE ENERGY CODE
2018 UNIVERSAL PLUMBING CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL FIRE CODE
WASHINGTON ADMINISTRATIVE CODE (WAC)
ADA STANDARDS FOR ACCESSIBLE DESIGN, 2010
AMMENDMENTS AS ADOPTED BY THE CITY OF RENTON
APPLICABLE CODES
NEW ENCLOSED HEATED SPACE NO CHANGE
MECHANICAL SYSTEM NO CHANGE
COMPLIANCE PATH PRESCRIPTIVE, WASHINGTON STATE ENERGY CODE
CH 51-11C WAC, C503.3.2.1
GLAZING U-VALUE (METAL FRAMING FIXED): 0.38
GLAZING U-VALUE (METAL FRAMING OPERABLE): 0.40
DOOR U-VALUE (METAL FRAMING) 0.60
ENERGY CODE NOTES
ADDRESS 243 W PERIMETER RD, RENTON, WA
PARCEL NUMBER 0723059007
OCCUPANCY CLASSIFICATION GROUP B - OFFICE
EXISTING BUILDING CONSTRUCTION TYPE V-B
LOT SIZE 6,640,728 SF
ZONING IM (MEDIUM INDUSTRIAL)
YEAR BUILT 1973
SPRINKLERS NO
NUMBER OF STORIES 1 STORY
EXISTING BUILDING SQUARE FOOTAGE 2,420 SF
AREA OF WORK 2,420 SF
SITE & BUILDING DATA 6,223'-7"AIRPORT WAYRAINIER AVE NE PERIMETER RDW PERIMETER RDRENTO N AVE SENLARGED
SITE PLAN
1 ,2 6 1 '-5 "
2,002'-9"
1 4 2 '-0 "104'-0"114'-0"47'-3"57'-7"18'-0"17'-9"21'-10"SIDEWALK
PROPERTY LINE
PARKING LOT
W PERIMETER RD
AIRPORT WAYRAINIER AVE SJohnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:58:07 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057PROJECT
INFORMATION
G001
RENTON MUNICIPAL AIRPORT OFFICE REMODEL
243 W PERIMETER RD
RENTON, WA 98057 PROJECT INFORMATION
G001 PROJECT INFORMATION
G002 GENERAL NOTES & CODE SUMMARY
G003 OCCUPANCY / EGRESS PLAN
ARCHITECTURAL
A200 DEMO & NEW FLOOR PLANS
A201 DEMO & NEW RCP
A202 FINISH PLAN
A500 EXTERIOR RAMPS
A700 INTERIOR ELEVATIONS - CONFERENCE & OFFICE
A701 INTERIOR ELEVATIONS - RECEPTION
A702 INTERIOR ELEVATIONS - RESTROOMS
A710 ACCESSIBILITY PLANS & DETAILS
A800 DOOR AND WINDOW SCHEDULE & DETAILS
A810 INTERIOR WALL ASSEMBLIES & DETAILS
A900 CASEWORK DETAILS
LOCATION PLAN
DRAWING INDEX
VICINITY MAP
SITE
405
AIRPORT WAYRAINIER AVE NRAINIER AVE SR E N T O N A V E S LOGAN AVE NPARK AVE NN SOUTHPORT DRSITE PLAN -ENLARGED SITE PLAN
1" = 40'1" = 1100'
GENERAL NOTES
THE CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN THE
CONSTRUCTION DRAWINGS AND SPECIFICATIONS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN
ACCORDANCE WITH ALL APPLICABLE SAFETY CODES.
THE CONTRACTOR SHALL INDEMNIFY AND HOLD JOHNSTON ARCHITECTS HARMLESS FOR
INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY NEGLIGENCE
OF CONTRACTOR, HIS AGENT, EMPLOYEES, OR SUBCONTRACTORS.
EACH CONTRACTOR/SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT
WORK AND IS RESPONSIBLE FOR THE REPAIR OF SAID DAMAGE AT THEIR OWN EXPENSE.
THE CONTRACTOR SHALL REPORT ERRORS AND OMISSIONS TO THE ARCHITECT
IMMEDIATELY IN WRITING. DO NOT VARY OR MODIFY THE WORK SHOWN EXCEPT UPON
WRITTEN INSTRUCTIONS OF THE ARCHITECT.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WALL BLOCKING AS
REQUIRED FOR ALL WALL AND CEILING MOUNTED ITEMS. COORDINATE WITH THE
ARCHITECT AND/OR OWNER LOCATION OF ALL MOUNTED ITEMS WHICH ARE N.I.C.
ALL CONSTRUCTION SHALL BE STABILIZED AGAINST LATERAL MOVEMENT IN
ACCORDANCE WITH REQUIREMENTS OF THE LATEST ADOPTED EDITION OF THE I.B.C. IN
THE LOCAL JURISDICTION AND IN STRICT ACCORDANCE WITH THE STRUCTURAL DETAILS
OF THIS SET OF DRAWINGS.
ALL WORK SHALL BE INSTALLED TRUE, PLUMB, SQUARE, LEVEL AND IN PROPER
ALIGNMENT.
OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH.
MECHANICAL, ELECTRICAL, VERTICAL TRANSPORTATION, & SPRINKLER WORK
CONDUCTED UNDER SEPARATE PERMIT & NOT PART OF THIS CONTRACT.
INSTALL ALL FIXTURES, EQUIPMENT, AND MATERIALS PER MANUFACTURER'S
SPECIFICATION.
EACH CONTRACTOR/SUBCONRACTOR SHALL BE RESPONSIBLE FOR LEAVING ALL AREAS
CLEAN AND READY FOR THEIR INTENDED USE.
CONTRACTOR SHALL GUARANTEE ALL WORK AGAINST FAULT OF ANY MATERIAL OR
WORKMANSHIP FOR PERIOD OF ONE YEAR AFTER COMPLETION AND ACCEPTANCE.
FAULTY WORK SHALL BE REPLACED OR REPAIRED AS REQUIRED AT CONTRACTOR'S
EXPENSE.
1.A
1.B
1.C
1.D
1.E
1.F
1.G
1.H
1.I
1.J
1.K
1.L
1.M
1. GENERAL:
THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT. AUTHORIZED
REPRODUCTION MUST BEAR THE NAME OF THE FIRM.
IN CASE OF DISCREPANCY OR AMBIGUITY, CONTACT THE ARCHITECT FOR CLARIFICATION
PRIOR TO PROCEEDING WITH ANY WORK.
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION, WHERE
CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE SIMILAR CHARACTER TO
DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED ONLY SUBJECT TO
REVIEW AND APPROVAL BY THE ARCHITECT.
CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR THE ARCHITECT'S APPROVAL PRIOR
TO MANUFACTURE OF ANY CABINET WORK, MILLWORK AND ANY OTHER SPECIAL ITEMS
REQUIRING CUSTOM SHOP FABRICATED WORK.
DRAWINGS INCLUDE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF
ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE COMPLETE OR REPRESENTATIVE OF
CONDITIONS OR MATERIALS SPECIFICALLY USED ON THE PROJECT. THE ARCHITECT WILL
DEFINE THE INTENT OF ANY DEFINITION OR TERM IN QUESTION.
3.A
3.B
3.C
3.D
3.E
3. DRAWINGS:
ALL WORK SHALL BE IN COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL
CODES INCLUDING BUT NOT LIMITED TO THE 2018 I.B.C., THE WASHINGTON STATE
ENERGY CODE AND GOVERNING MECHANICAL CODE WITHIN THE JURISDICTION OF THE
PROJECT. IN CASE OF CONFLICT WHERE METHODS OR STANDARDS OF INSTALLATION OR
MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR
ORDINANCES, THE ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF ANY
CONFLICT.
IMPORTANT: IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND EACH AND
EVERY SUBTRADE TO ENSURE EVERY ASPECT OF THIS WORK IS IN COMPLIANCE WITH
THE PREVAILING CODES.
2.A
2.B
2. CODES:
DO NOT SCALE THESE DRAWINGS. ALL INFORMATION SHOWN ON THE DRAWINGS
RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT
WITHOUT GUARANTEE OF ACCURACY. THE CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES OR CONDITIONS ADVERSELY EFFECTING THE DESIGN PRIOR TO
PROCEEDING WITH THE ITEM OF WORK EFFECTED.
DIMENSIONS ON THE PLANS ARE TO FACE OF STRUCTURE, UNLESS OTHERWISE NOTED.
5.A
5.B
5. DIMENSIONS:
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION AND
COORDINATION OF THE WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH THE
DRAWINGS AND SPECIFICATIONS.
6.A
6. COORDINATION:
FIRE PROTECTION CONTRACTORS SHALL PROVIDE FIRE PROTECTION DRAWINGS
REQUIRED BY GOVERNING AUTHORITY. DRAWINGS SHOULD BE SUBMITTED TO THE
ARCHITECT FOR REVIEW.
PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RATED ELEMENTS REQUIRED
BY THE FIRE OFFICIAL.
EXISTING FIRE ALARM SYSTEMS SHALL REMAIN INTACT AND OPERABLE AT ALL TIMES.
7.A
7.B
7.C
7. FIRE PROTECTION:
THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING COMPLIANCE
WITH ALL CODES AND OBTAINING ALL NECESSARY PERMITS.
ALL DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BY THE
ARCHITECT.
THE ELECTRICAL CONTRACTOR SHALL VERIFY THE LOCATION OF EACH CORE DRILL WITH
THE EXISTING STRUCTURE, PIPING, CONDUIT, ETC. AND SHALL NOTIFY THE ARCHITECT
OF ANY CONFLICTS OR OBSTRUCTIONS.
ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONTRACT DOCUMENTS
SHOULD BE CALLED TO THE ATTENTION OF THE ARCHITECT.
ALL NEW ELECTRICAL/TELEPHONE OUTLETS ARE TO BE MOUNTED VERTICALLY AT 18" AFF
UNLESS NOTED. ALL NEW ELECTRICAL/TELEPHONE OUTLETS OVER COUNTERS ARE TO
BE MOUNTED VERTICALLY AT 44" AFF UNLESS NOTED. ALL WALL MOUNTED
RECEPTACLES LOCATED IN CASEWORK ARE TO BE MOUNTED HORIZONTALLY UNLESS
OTHERWISE NOTED.
SPECIAL HEIGHTS ARE NOTED ADJACENT TO THE OUTLET.
THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING COMPLIANCE
WITH ALL ADA REQUIREMENTS FOR HEIGHTS OF FIXTURES AND DEVICES (I.E. SWITCHES,
OUTLETS ETC.)
8.A
8.B
8.C
8.D
8.E
8.F
8.G
8. ELECTRICAL NOTES:
ALL FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND
REQUIRE THE ARCHITECT'S APPROVAL PRIOR TO INSTALLATION. PROVIDE ARCHITECT 3
SAMPLES PER FINISH FOR ARCHITECTS REVIEW BEFORE ORDERING.
10.A
10. FINISH NOTES:
# NUMBER
∠ANGLE
ACST ACOUSTICAL
ADA AMERICANS WITH
DISABILITIES ACT
ADDL ADDITIONAL
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECT (URAL)
ASTM AMERICAN SOCIETY FO
TESTING MATERIALS
AWI ARCHITECTURAL
WOODWORKING INSTITUTE
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BO BOTTOM OF
BOF BOTTOM OF FOOTING
CAB CABINET
CB CATCH BASIN
C.C. CENTER TO CENTER
CFM CUBIC FEET PER MINUTE
CFOI CONTRACTOR FURNISHED;
OWNER INSTALLED
CH CHANNEL
CI CAST IRON
CIP CAST-IN-PLACE (CONCRETE)
CL CENTERLINE
CLG CEILING
CLR CLEAR
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
CPT CARPET (ED)
CSMT CASEMENT
CT CERAMIC TILE
D DEEP
° or DEG DEGREE
DEMO "DEMOLISH, DEMOLITION"
DEPT DEPARTMENT
DET DETAIL
⌀or DIA DIAMETER
dB DECIBEL
DIM DIMENSION
DN DOWN
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWR DRAWER
(E) EXISTING
E EAST
EA EACH
EL ELEVATION
ELEC ELECTRIC (AL)
ENCL ENCLOSE (URE)
EQ EQUAL
EQUIP EQUIPMENT
ESMT EASEMENT
EST ESTIMATE (D)
EW EACH WAY
EXH EXHAUST
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH (ED)
FL FLASHING
FLR FLOOR
FM FACTORY MANUAL
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOIC FURNISHED BY OWNER
INSTALLED BY CONTRACTOR
FOIO FURNISHED BY OWNER
INSTALLED BY OWNER
FOS FACE OF STUDS
FRMG FRAMING
FRT FIRE RETARDANT TREATED
FT "FOOT, FEET"
FTG FOOTING
FURN FURNITURE
G NATURAL GAS
GA GAGE
GAL GALLON
GALV "GALVANIZED, GALVANIC"
GAR GARAGE
GB GRAB BAR
GC GENERAL CONTRACTOR
GEN GENERAL
GL GLASS
GLU LAM GLUED LAMINATED WOOD
GOVT GOVERNMENT
GSM GALVANIZED SHEET METAL
GWB GYPSUM WALL BOARD
H HEIGHT
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HLDN HOLDDOWN
HM HOLLOW METAL
HO HOLD OPEN
HORIZ HORIZONTAL
HR HOUR
HVAC "HEATING, VENTILATION, AND
AIR CONDITIONING"
HWH HOT WATER HEATER
ID INSIDE DIAMETER
IIC IMPACT ISOLATION CLASS
IN INCH (S)
INCL INCLUDING (ED)
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JST JOIST (S)
KIT KITCHEN
KW KILOWATT
L LENGTH
LAM LAMINATE(D), LIQUID APPLIED
MEMBRANE
LAV LAVATORY
ABBREVIATIONS
LB (S) POUND (S)
LF LINEAL FOOT/FEET
LH LEFT HAND
LHR LEFT HAND REVERSE
LNDSCP LANDSCAPE
LOC LOCATION
LTG LIGHTING
LVL LAMINATED VENEER LUMBER
MACH RM MACHINE ROOM
MAG MAGNET(IC)
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MEP MECHANICAL, ELECTRICAL,
PLUMBING
MFD MANUFACTURED
MFR MANUFACTURER
MIN "MINIMUM, MINUTE"
MIRR MIRROR
MISC MISCELLANEOUS
MTL METAL
MULL MULLION
MULT MULTIPLE
(N) NEW
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
N NORTH
NTS NOT TO SCALE
O/ OVER
OA OVERALL
OC ON CENTER
OD "OUTSIDE DIAMETER, DIMENSION"
OFF OFFICE
OH OVERHANG
OPP HAND OPPOSITE HAND
OPNG OPENING
OVHD OVERHEAD
PBD PARTICLE BOARD
PED PEDESTAL
PERF PERFORATED
PERIM PERIMETER
PERM PERMANENT
PERP PERPENDICULAR
PH PHASE
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLWD PLYWOOD
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PRKG PARKING
PROJ PROJECT
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSL PARALLEL STRAND LUMBER
PTD PAINTED
PTN PARTITION
PVA POLYVINYL ACRYLIC
PVC POLYVINYL CHLORIDE
PVG PAVING
QTY QUANTITY
R "RADIUS, RISER"
RCP REFLECTED CEILING PLAN
RD "ROOF DRAIN, ROAD"
REC RECESSED
REF "REFER (ENCE),
REFRIGERATOR"
REINF "REINFORCE (D), (ING)"
REQD REQUIRED
RESIL RESILIENT
REV "REVISION (S), REVISED"
RH "ROOF HATCH, RIGHT HAND"
RHR RIGHT HAND REVERSE
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RT RIGHT
RWL RAINWATER LEADER
S SOUTH
SCHED SCHEDULE
SD STORM DRAIN
SF SQUARE FOOT (FEET)
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SPKLR SPRINKLER
SQ SQUARE
SQ IN SQUARE INCH
SST STAINLESS STEEL
ST "STAIRS, STREET"
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE (AL)
SUSP SUSPEND(ED)
SV SHEET VINYL
T TREAD
TBD TO BE DETERMINED
TEL TELEPHONE
TEMP TEMPORARY
TFF TOP OF FINISH FLOOR
THK THICK (NESS)
THRU THROUGH
TOB TOP OF BEAM
TOC TOP OF CURB
TOW TOP OF WALL
TYP TYPICAL
UBC UNIFORM BUILDING CODE
UL UNDERWRITERS
LABORATORIES
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
V VOLT
W "WEST, WIDTH, WASHER"
W/ WITH
W/O WITHOUT
WD "WOOD, WOOD DOOR"
WDW WINDOW
WRB WEATHER RESISTIVE BARRIER
E
4
X
X
144.25'
NEW COLUMN GRIDS
EXIST/ADJ BLDG
COLUMN GRIDS
NORTH ARROW
BUILDING ELEVATION
DRAWING NUMBER
SHEET NUMBER
INTERIOR ELEVATION
DRAWING NUMBER
SHEET NUMBER
BUILDING SECTION
DRAWING NUMBER
SHEET NUMBER
WALL SECTION
DRAWING NUMBER
SHEET NUMBER
DETAIL
DRAWING NUMBER
SHEET NUMBER
SPOT ELEVATION
MATCHLINE
DRAWING SHT.
SHOWING ADJ. CONDITION
DATUM / CONTROL POINT
CONTOURS
REVISED CONTOURS
EXISTING CONTOURS
NEW WALL
EXISTING WALL
WALL TO BE REMOVED
FINISH TAG
CEILING HEIGHT TAG
ROOM TAG
DOOR TAG
WINDOW TAG
ASSEMBLY TAG
(WALL, FLOOR, CLG, ROOF)
REVISION TAG /
REVISION CLOUD
EXIT SIGN
FIRE EXTINGUISHER
SMOKE DETECTOR
8'-0"
P-1
A310
1A
1B
1C
1D
A1
A201
A1
A210
A1
A501
A01
0101A
1t
1
MATCH LINE
SEE XX/X-XXX
FECA1
A210
ROOM
101
SYMBOL LEGEND
NJohnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:58:07 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057GENERAL NOTES &
CODE SUMMARY
G002
284 SF
OFFICE
390 SF
RECEPTION
229 SF
OFFICE
347 SF
CONFERENCE
200 SF
OFFICE
235 SF
OFFICE REQUIRED SEPARATION73'-3" / 2 = 36' 7 1/2"Building Common Area
Office Area
ASSEMBLY AREA .
40'-7"OCCUPANCY: 23
OCCUPANCY: 1
OCCUPANCY: 2
OCCUPANCY: 2
OCCUPANCY: 2
OCCUPANCY: 26
41"
60"
OCCUPANCY LOAD
SERVED BY DOOR &
HALLWAY: 26
IBC TABLE 1006.2.1
MAX 75' COMMON PATH OF TRAVEL
DISTANCE
52' TRAVEL DISTANCE PROVIDED
IBC TABLE 1017.2
MAX 200' TRAVEL DISTANCE
77'-9" TRAVEL DISTANCE PROVIDED
EXIT
EXIT
OFFICE AREA .
OCCUPANCY LEGEND 5'-6"COMMON PATH OF TRAVEL
PATH OF EGRESS
DECISION POINT
EXIT SIGN
EGRESS PLAN LEGEND
Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:58:09 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057OCCUPANCY /
EGRESS PLAN
G003
OCCUPANCY LOAD
NAME OCCUPANCY AREA OCCUPANT LOAD FACTOR NUMBER OF OCCUPANTS CALCULATED NUMBER OF OCCUPANTS
RECEPTION A3 390 SF 15 26.02 26
CONFERENCE A3 347 SF 15 23.14 23
OFFICE B 284 SF 150 1.90 2
OFFICE B 229 SF 150 1.52 2
OFFICE B 200 SF 150 1.33 1
OFFICE B 235 SF 150 1.57 2
6 1685 SF 55.48 56
SCALE: 3/16" = 1'-0"
OCCUPANCY / EGRESS PLAN1
N
02'12'16' 4'8'
AREA
TOTAL FLOOR AREA 2,420 SF
PROJECT AREA OF WORK 2,420 SF
OCCUPANCY LOAD CALCULATIONS
SEE OCCUPANCY SCHEDULE
EXIT REQUIREMENTS
NUMBER OF EXITS REQUIRED 2
NUMBER OF EXITS PROVIDED 2
EGRESS WIDTH (INCHES) REQUIRED 0.2 X 56 = 11.2"; 44" MIN
EGRESS WIDTH (INCHES) PROVIDED 60"
EGRESS WIDTH (INCHES) REQUIRED
WHERE OCCUPANCY SERVED < 50 36" MIN
EGRESS WIDTH (INCHES) PROVIDED
WHERE OCCUPANCY SERVED < 50 41" MIN
EXIT SEPARATION
NOT SPRINKLERED
REQUIRED EXIT SEPARATION > 1/2 DIAGONAL
SEPARATION PROVIDED SEE PLAN
COMMON PAHTH OF TRAVEL
NOT SPRINKLERED
MAXIMUM COMMON PATH OF TRAVEL 75'
IBC TABLE 1006.2.1
MAXIMUM EXIT ACCESS TRAVEL DISTANCE 200'
IBC TABLE 1017.2
EGRESS SUMMARY
33333DEMO EXISTING
FLOORING
THROUGHOUT TYP
DEMO (E) PARTITIONS & (E)
DOOR, PATCH AND REPAIR AS
NEEDED
DEMO (E) BAR, PROTECT (E)
PLUMBING IN WALL FOR REUSE
DEMO (E) PARTITIONS & (E)
DOOR, PATCH AND REPAIR AS
NEEDED
DEMO (E) RESTROOM FIXTURES
AND FLOORING. PROTECT (E)
PLUMBING IN WALL FOR REUSE.
PATCH AND REPAIR WALL AS
NEEDED.
DEMO (E) RESTROOM FIXTURES
AND FLOORING. PROTECT (E)
PLUMBING IN WALL FOR REUSE.
PATCH AND REPAIR WALL AS
NEEDED.
DEMO EXISTING
FLOORING
THROUGHOUT TYP
DEMO EXISTING
FLOORING
THROUGHOUT TYP
DEMO EXISTING
FLOORING
THROUGHOUT TYP
DEMO EXISTING
FLOORING
THROUGHOUT TYP
DEMO EXISTING
FLOORING
THROUGHOUT TYP
DEMO EXISTING
DECKING AND
RAILING, PREP FOR
NEW
DEMO DOORS PREP FOR NEW,
TYP
REVERSE SWING OF
EXISTING DOOR PER
NEW PLAN -KEEP
EXISTING DOOR &
FRAME
REMOVE BROKEN WINDOW
REMOVE EXISTING SLIDER DOOR
REMOVE BROKEN WINDOW
REMOVE BROKEN WINDOW 2'-1"SAW CUT SLAB FOR
NEW FLOOR OUTLET
OFFICE
3
MECH
4
RECEPTION &
LOUNGE
1
OFFICE
6
CONFERENCE &
BREAKROOM
7
OFFICE
9
RESTROOM
10
OFFICE
11
NEW WOOD DECKING
AND RAILING TO
REPLACE EXISTING.
RAILING TO MATCH
EXISTING
REPLACE BROKEN WINDOW
WITH BUILDING TYP WINDOW
COUNTER 34"AFF
OUTDOOR
LOUNGE
2
NIC
IT ALCOVE
RESTROOM
5
(E) AC
6'-1"11
10
3c
COPY
8
NEW ACCESSIBLE RAMP.
SLOPE 1:12
NEW ACCESSIBLE RAMP. SLOPE 1:123'-6"5'-0"10'-0"5'-1"CLR
5'-2"13'-0"5'-2"3'-6"COUNTER 34"AFF
5
(e)
(e)
1a
1b
1c
9
SLIDING SCREENS
29" HIGH RECEPTION COUNTER,
PROVIDE POWER AND DATA IN DESK
A3a
A3a
A3a A3a
A3a
________
A500
2
________
A500
1
________
A702
3
________
A702
2
________
A701
6
EXISTING OUTLETS SHOWN
HALFTONE, VIF & NOTIFY ARCH
WITH DISCREPANCIES
RELOCATE SWITCHES
GFIC GFICREF
44" AFF
CRCRCRPROVIDE NEW COVER PLATES
FOR ALL ELECTRICAL FIXTURES
TO REMAIN, TYP THROUGHOUT
PROVIDE NEW WINDOW WHERE EXISTING
SLIDER DOOR WAS REMOVED, VERIFY
SIZE IN FIELD
VERFIY FLOOR
LOCATION WITH FURN
VENDOR
PAINT EXISTING EXTERIOR
METAL SIDING. ASSUME TWO
COLORS, 1 MAIN COLOR AND 1
ACCENT TRIM COLOR. AVCORDINATE IT POWER
REQUIREMENTS WITH
OWNER & IT
PROVIDE BACKING
FOR WALL MOUNTED
IT RACKS AS NEEDED
3a5'-6"5'-8"2'-4"PRINT8"CLEAR
5'-0"4'-1"
6
UPGRADE TO KEY PAD LOCK
7
3b
IN DESK POWER DATA
SEE (A701)
REPLACE BROKEN WINDOW
WITH BUILDING TYP WINDOW
REPLACE BROKEN WINDOW
WITH BUILDING TYP WINDOW
UP
UPDECK STRUCTURE TO
REMAIN. GC TO VERIFY
INTEGRITY IN FIELD.
FEC
FEC
FEC
FEC
PRINTER, CONFIRM POWER DATA
REQUIREMENTS PER PRINTER
NEW WALL
EXISTING WALL
WALL TO BE REMOVED
WALL LEGEND
POWER LEGEND
1. ASBESTOS & HAZARDOUS MATERIALS: FEDERAL, STATE & LOCAL REGULATIONS
REQUIRE THAT ALL ASBESTOS & OTHER HAZARDOUS MATERIALS IN A BUILDING BE
REMOVED PRIOR TO STARTING THE DEMOLITION WORK. CONTRACTOR TO OBTAIN
REQUIRED CERTIFICATION THAT THERE ARE NO HAZARDOUS MATERIALS PRESENT IN
THE STRUCTURE.
2. U.O.N. ALL DEBRIS RESULTING FROM DEMOLITION WORK SHALL BECOME THE PROPERTY
OF THE CONTRACTOR & SHALL BE REMOVED & DISPOSED OF IN A LEGAL MANNER OFF
OF THE PROJECT PROPERTY.
3. SEE MEP (UNDER SEPARATE PERMIT), FIRE PROTECTION (UNDER SEPARATE PERMIT),
ELECTRICAL (UNDER SEPARATE PERMIT) & COMMUNICATION (UNDER SEPARATE PERMIT)
DOCUMENTS FOR DEMOLITION RELATED TO THOSE TRADES.
4. MEP, FIRE PROTECTION, ELECTRICAL, AND COMMUNICATION PERMITS ARE THE
RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL COORDINATE DEMOLITION
NEEDS OF THOSE TRADES.
5. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO ADEQUATELY SECURE THE PREMISES
& /OR STORED MATERIALS FROM TRESPASSING, THEFT & VANDALISM.
6. PROTECT EXISTING WINDOWS AT PERIMETER DURING CONSTRUCTION. CLEAN
WINDOWS PRIOR TO OCCUPANCY.
7. DEMO ALL FLOORING FINISHES IN AREAS OF WORK U.O.N.; PATCH &
PREPARE EXISTING FLOORS IN AREAS TO RECEIVE NEW FLOORING TO
PROVIDE FOR CONTINUOUS "LEVEL" SURFACE FOR NEW FLOORING.
8. DO NOT REMOVE ANY BEARING WALLS, COLUMNS OR OTHER
STRUCTURAL MEMBERS NOT DESIGNATED IN THE DOCUMENTS. NOTIFY
ARCHITECT IMMEDIATELY IF AREAS OF DEMO UNCOVER ANY EXISTING
STRUCTURAL COMPONENTS NOT PREVIOUSLY IDENTIFIED.
9. REMOVE ALL WALLCOVERING ON WALLS TO REMAIN
10. PRIOR TO REMOVAL OF ANY STRUCTURAL COMPONENTS, THE
CONTRACTOR SHALL PROVIDE SHORING AS REQUIRED TO TEMPORARILY
SUPPORT ALL LOADS UNTIL NEW FRAMING IS INSTALLED AS
DOCUMENTED AND SPECIFIED. IF THE CONTRACTOR FINDS THE EXISTING
CONDITIONS TO BE OTHER THAN DOCUMENTED OR IN CONFLICT WITH
THE DRAWINGS, NOTIFY THE ARCHITECT IMMEDIATELY FOR RESOLUTION.
PROCEEDING WITHOUT NOTIFICATION INDICATES FULL ACCEPTANCE OF
CONDITIONS AND RESPONSIBILITY IF WORK IS NOT IN CONFORMANCE
WITH CONTRACT DOCUMENTS.
11. ALL EXISTING ELECTRICAL OUTLETS, SWITCHES AND FACE PLATES TO
REMAIN SHALL BE PROTECTED DURING DEMOLITION AND/OR SAVED FOR
FUTURE USE AS INDICATED IN THE DOCUMENTS. CONSULT POWER
PLANS FOR SPECIFIC ELECTRICAL WORK.
DEMO NOTES
1. EXISTING SHELL & CORE CONSTRUCTION SHOWN w/ WHITE POCHE
2. REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL DIMENSIONS DESCRIBING
PARTIAL HEIGHT WALLS, CASEWORK LAYOUT, SPECIALTY OUTLET LOCATIONS,
ETC.
3. REFER TO REFLECTED CEILING PLANS FOR SOFFITS, CEILING HEIGHTS & PLENUM
BARRIER LOCATIONS.
4. REFER TO SHEET G002 FOR ADDITIONAL NOTES, LEGENDS, SYMBOLS,
ABBREVIATIONS, & SCHEDULES.
5. PATCH/REPAIR, PRIME & PAINT ALL EXISTING GWB WALLS TO REMAIN.
6. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO
FINISH FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ALL DIMENSIONS
MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED & SHALL ALLOW FOR THICKNESS
OF ALL WALL FINISHES, UON & SHALL NOT VARY MORE THAN ± 1/8" WITHOUT
WRITTEN INSTRUCTION FROM ARCHITECT.
7. PARTITIONS THAT ARE NOT DIMENSIONED ARE TO BE LOCATED FLUSH & SQUARE
WITH THE EXISTING PARTITION OR CENTERLINE OF WINDOW MULLION AS SHOWN.
8. WALLS THAT APPEAR TO ALIGN DO ALIGN. WALLS THAT APPEAR CENTERED ON
COLUMNS OR MULLIONS ARE CENTERED ON COLUMNS OR MULLIONS.
9. "ALIGN" MEANS TO ACCURATELY LOCATE THE FINISHED FACES IN
THE SAME PLANE.
10. DIMENSIONS MARKED ± MEAN A TOLERANCE NOT GREATER NOR
SMALLER THAN 2 INCHES FROM INDICATED DIMENSION, U.N.O.
VERIFY FIELD DIMENSIONS EXCEEDING TOLERANCE WITH THE
ARCHITECT. SECURE ARCHITECT'S APPROVAL.
11. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR
CONFLICTS IN THE LOCATION(S) OF NEW CONSTRUCTION. UPON
COMPLETION OF PARTITION LAYOUT, NOTIFY ARCHITECT. ALLOW
TIME IN THE SCHEDULE FOR VERIFICATION OF THE LAYOUT BY THE
ARCHITECT PRIOR TO PARTITION INSTALLATION.
12. ALL WORK SHALL BE ERECTED & INSTALLED PLUMB, LEVEL,
SQUARE & TRUE.
13. DIMENSIONS LOCATING DOORS ARE TO FINISHED OPENING, UON.
14. COPY/PRINT, INTERIOR PLANTS, AND FURNITURE EQUIPMENT TO
BE PROVIDED BY OWNER.
15. ALL NEW WALLS TO BE LEVEL 4 FINISH, LEVEL 5 AT
WALLCOVERING.
NEW PLAN NOTES
1. POWER AND DATA REQUIREMENTS TO BE VERIFIED WITH CONTRACTOR'S ELECTRICAL
DESIGN-BUILD ENGINEER.
2. ALL POWER/DATA OUTLETS TO BE LOCATED @ +18" A.F.F., U.O.N.
3. ALL POWER/DATA OUTLETS ABOVE COUNTERS TO BE LOCATED @ +44" A.F.F, U.O.N.
4. PROVIDE ELECTRICAL POWER FOR ALL NEW APPLIANCES.
5. SERVE NO MORE THAN 6 GENERAL PURPOSE OUTLETS FROM A SINGLE 20A, 120V
CIRCUIT.
6. IN-FEED FOR WORKSTATION POWER -TYPICAL TO BE 20 AMP CIRCUITS NON-
DIRECTIONAL 8-WIRE CONFIG.: 4 HOTS, 2NEUTRAL, 2 GROUNDS. CONTRACTOR TO
CONNECT ELECTRICAL TO WORKSTATION. PANEL-TO-PANEL CONNECTION TO BY BY
FURNITURE VENDOR.
7. CONFIRM LOCATIONS OF ALL FURNITURE POWER FEEDS WITH FURNITURE VENDOR
PRIOR TO ROUGH-IN.
8. VERIFY CONFIGURATION OF FLUSH POKE-THRU DEVICES WITH TENANT AV CONSULTANT
AND ARCHITECT PRIOR TO INSTALLATION.
9. ALL DEVICES AND COVER PLATES TO BE WHITE U.O.N. SEE FINISH SCHEDULE FOR
COVERPLATE INFORMATION
POWER PLAN NOTES
10. CONTRACTOR TO PULL OWNER-PROVIDED CAT-6 CABLE
TO LOCATIONS SHOWN ON PLAN; OWNER WILL TERMINATE AT
IT CABINET.
11. SPEAKERS AND ASSOCIATED CABLING BY TENANT'S
SELECTED VENDOR. GC TO COORDINATE LOCATIONS AND
WORK WITH VENDOR.
12. IT ALCOVE REQUIREMENTS: CONFIRM FINAL LAYOUT /
CONFIGURATION AND LOCATION OF OUTLETS WITH OWNER.
13. COORDINATE LOCATION OF ELECTRICAL OUTLETS FOR
WALL MOUNTED MONITORS WITH OWNER'S AV CONSULTANT
14. CONTRACTOR TO PULL OWNER-PROVIDED SECURITY
CAMERA WIRING. OWNER WILL COORDINATE SECURITY
CAMERA INSTALL WITH THEIR VENDOR.
15. CONTRACTOR TO PROVIDE POWER AT CARD-READER
LOCATIONS NOTED. OWNER TO SUPPLY & INSTALL CARD-
READERS.
FLUSH FLOOR OUTLET W/
POWER AND TEL/DATA
CONNECTION - ALL
LOCATIONS TO BE RJ45
CAT6, 2 PORT UONGFICEXISTING DUPLEX,
CONTRACTOR TO VIF
DUPLEX
GFCI DUPLEX
DATA - ALL LOCATIONS
TO BE RJ45 CAT6,2 PORT
UON
DATA - ALL LOCATIONS
TO BE RJ45 CAT6,2 PORT
UON
CRCARD READERAV Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:57:54 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057DEMO & NEW
FLOOR PLANS
A200
SCALE: 3/16" = 1'-0"
DEMO PLAN2
N
SCALE: 3/16" = 1'-0"
NEW FLOOR PLAN1
02'12'16'4'8'
N
02'12'16' 4'8'
333333L-1 L-1EM
L-1L-1
L-1
L-1
L-1
L-1
E-4
E-4
E-4E-4REMOVE EXISTING SWITCHES
LOCATED IN CASEWORK
WALL. RELOCATE PER PLAN
L-1EM L-1L-1 L-1
REPLACE E-3 LIGHT FIXTURES WITH
NEW L-1 IN EXISTING LOCATIONS, TYP
D-1
PROTECT E-4 SCONCE
DURING COSTRUCTION,TYP
PAINT ALL EXISTING GRILLS
AND MECHANICAL TO
REMAIN TO MATCH
CEILING, TYP
THROUGHOUT
MATCH SPACING OF EXSITING FIXTURES+/- 6'-8"L-1
L-1
2'-6"2'-6"4'-0"
L-1EM
4'-0"
L-1 EQEQEQ EQ
L-1W
L-1 L-1
ALIGN W/ EXISTING
3'-3"
L-1 L-1EMALIGN W/ EXISTINGL-1EML-1
4'-5"4'-5"
L-1L-1
3'-3"3'-3"L-1WEQ
EQSEE ELEVATIONS FOR WALL
SCONCE LOCATIONS
L-1W2'-5"
2'-5"
SEE ELEVATIONS FOR
WALL SCONCE LOCATION
D-1D-1
2'-6"3'-6"3'-6"3'-9"L-1
L-1
L-1
L-1 L-1
2'-6"2'-6"EQ2'-6"L-1
L-1
L-1EM
4'-6"4'-7"
L-1L-1L-1
L-1EM
L-1L-1
D-2
EQ 5'-1"5'-1"EQ
D-2 D-2
WAP
EQ2'-6"EQEQ9"9"ALIGN WITH
(E) FIXTURE
L-1
L-1
8'-0" 8'-0"
L-1
8'-0"L-1EM EQEQEQ EQ
L-1
7'-0"
L-1EM
7'-0"EQEQCAM
CAMB/CAM
B
WAP
ALIGN WITH (E)
FIXTURE
WAP
WAP
SD
SD
SD
SD SD
SD
SD SD
SD
SD
SD B/CAM
WOOD CEILING TO BE
PAINTED TO MATCH
NEW GWB CEILING
PANT
WOOD CEILING TO BE
COVERED W/ GWB IN
THIS AREA
ENCAPSULATE POPCORN CEILING WITH (2) LAYER 1/4"
GWB ON ALL EXISTING CEILINGS THAT APPLY, VERIFY
LOCATIONS IN FIELD. PROVIDE LEVEL 4 FINISH
SC-1
SC-1SC-1
E-4
EXISTING T-STAT
TO REMAIN
RELOCATE EXISTING T-STAT AS
NEEDED TO ACCOMODATE NEW WALL
MECH ROOM
LIGHTING NOT
IN SCOPE
E-3
E-3E-3
E-3
E-3
E-3
E-3
E-4
E-4 E-5
E-6
E-4
E-1
E-2
E-4
E-1
E-3E-3
E-3
E-5
EXISTING T-STAT
TO REMAIN
RELOCATE EXISTING T-STAT AS
NEEDED TO ACCOMODATE NEW WALL
ETHERNET
E-1
E-1
E-1
E-1
E-1
E-1 E-1
E-1 E-1
E-2
E-3
E-7
E-3E-3
E-1 E-1
E-1
E-1 E-1
EXISTING POPCORN CEILING TO REMAIN
PATCH EXISTING CEILING
WHERE DEMO'D WALLS
OCCUR
PATCH EXISTING CEILING
WHERE DEMO'D WALLS
OCCUR, TYP. PROVIDE A
LEVEL 4 FINISH
SALVAGE FOR REUSE
SALVAGE FOR REUSE
REMOVE SWITCH
WOOD CEILING TO
REMAIN IN THIS AREA
SALVAGE RESTROOM
EXHAUST FAN COVERS
FOR REUSE, TYP
SALVAGE ALL SUPPLY &
RETURN AIR DIFFUSERS
FOR REUSE, TYP
LIGHT SWITCHES SHOWN ON THE DEMO RCP
ARE FOR REFERENCE ONLY. ALL EXISTING
SWITCHES SHALL BE REMOVED, WALLS
PATCHED, AND NEW SWITCHES INSTALLED.
E-4
1. ASBESTOS & HAZARDOUS MATERIALS: FEDERAL, STATE & LOCAL
REGULATIONS REQUIRE THAT ALL ASBESTOS & OTHER HAZARDOUS
MATERIALS IN A BUILDING BE REMOVED PRIOR TO STARTING THE
DEMOLITION WORK. CONTRACTOR TO OBTAIN REQUIRED
CERTIFICATION THAT THERE ARE NO HAZARDOUS MATERIALS
PRESENT IN THE STRUCTURE.
2. U.O.N. ALL DEBRIS RESULTING FROM DEMOLITION WORK SHALL
BECOME THE PROPERTY OF THE CONTRACTOR & SHALL BE REMOVED
& DISPOSED OF IN A LEGAL MANNER OFF OF THE PROJECT PROPERTY.
3. ELECTRICAL & MECHANICAL PERMITS ARE THE RESPONSIBILITY OF
THE CONTRACTOR. CONTRACTOR SHALL COORDINATE DEMOLITION
NEEDS.
4. THE CONTRACTOR SHALL PROTECT THE EXISTING BUILDING &
IMPROVEMENTS WITHIN THE AREAS OF OPERATION & TAKE CARE TO
PROTECT THE NEIGHBORING SPACES WHERE EXISTS. THE
CONTRACTOR SHALL ASSUME ALL FINANCIAL RESPONSIBILITY FOR
THE IMMEDIATE RESTORATION, REPAIR, OR REPLACEMENT OF
DAMAGED ITEMS OR AREAS TO RESTORE THEM TO MATCH EXISTING
CONDITIONS .
DEMO RCP NOTES
1. ALL GWB SOFFITS AND CEILINGS TO BE PAINTED PT-1,
FLAT FINISH, U.O.N.
2. HEIGHTS NOTED ARE ABOVE FINISHED FLOOR, U.O.N.
3. REFER TO INTERIOR ELEVATIONS FOR MOUNTING
HEIGHT OF WALL SCONCES.
4. VERIFY LOCATIONS OF ACCESS PANELS WITH ABOVE
CEILING DEVICES & CONTROLS - PAINT TO MATCH
ADJACENT SURFACE.
5. ALL LIGHT FIXTURES TO BE 3000K, U.O.N
6. CONTRACTOR TO VERIFY ENERGY CODE COMPLIANCE
AND PROVIDE ALL NECESSARY CODE REQUIRED ITEMS.
RCP NOTES LIGHTING LEGEND
= SWITCH
= 3 WAY SWITCH
= 4 WAY SWITCH
S
S
S
3
4
= STANDARD DUPLEX OUTLET
= (E) SURFACE MOUNT FLUORESCENT
LIGHT FIXTURE
= (E) CEILING MOUNT FLUORESCENT
LIGHT FIXTURE, WOOD CASING
= RECESSED CAN LIGHT FIXTURE
= (E) HALLWAY SCONCE LIGHT FIXTURE
= (E) BATHROOM SCONCE LIGHT FIXTURE,
ROUND
= (E) BATHROOM SCONCE LIGHT
FIXTURE, RECTANGLE
= (E) TRACK LIGHT
= (E) FAN
= (E) AIR REGISTER
= (E) AIR RETURN
= (E) COVERPLATE
= SECURITY CAMERA PER CLIENTCAM
= BUZZER WITH SECURITY CAMERA
PER CLIENT
B/CAM
= WAP, PROVIDE DATA AND
POWER IN CEILING FOR WIFI
DEVICE
SD SMOKE DETECTOR
= BUZZERB
Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:57:54 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057DEMO & NEW RCP
A201
N
02'12'16' 4'8'
N
02'12'16' 4'8'
SCALE: 3/16" = 1'-0"
NEW RCP1SCALE: 3/16" = 1'-0"
DEMO RCP2
LIGHTING LEGEND
MARK DESCRIPTION MFR / VENDOR MODEL COLOR / FINISH LAMPING / TEMP COMMENTS
D-1 DECORATIVE PENDANT RICH BRILLANT WILLING GP-10G-PC30-30-120_TM_DEX-CPYB MATTE BLACK LED / 3000K MOUNT AT 6'-0" BOTTOM OF FIXTURE
D-2 DECORATIVE PENDANT RICH BRILLANT WILLING CTF-18-PC30-30-277_10_DIN MATTE BLACK LED / 3000K SURFACE MOUNTED
E-1 EXISTING FLUORESCENT LIGHT EXSITING REMOVE, PATCH AND REPAIR CEILING
E-2 EXISTING FLUORESCENT LIGHT -
WOOD
EXISTING REMOVE, PATCH AND REPAIR CEILING
E-3 EXISTING RECESSED CAN EXISTING REPLACE WITH L-1 PER PLAN
E-4 EXISTING HALLWAY SCONCE EXISTING SALVAGE FIXTURES FOR RE-USE WHERE LOCATIONS ARE CHANGING
E-5 EXISTING BATHROOM SCONCE -
ROUND
EXISTING REMOVE, PATCH AND REPAIR WALL
E-6 EXISTING BATHROOM SCONCE -
REC
EXISTING REMOVE, PATCH AND REPAIR WALL
E-7 EXISTING TRACK LIGHT EXISTING REMOVE, PATCH AND REPAIR CEILING
L-1 RECESSED CAN LIGHT FOCAL POINT FLCS3, RO, 1300L, 30K, FL, 120V, LD1, IC. TRIM & LED
MOD: LCS3,RO,AA,WH,WH
WHITE LED / 3000K ACCENT ADJUSTABLE
L-1EM RECESSED CAN LIGHT
(EMERGENCY)
FOCAL POINT FLCS3, RO, 1300L, 30K, FL, 120V, LD1, IC. TRIM & LED
MOD: LCS3,RO,AA,WH,WH
WHITE LED / 3000K EMERGENCY BACK-UP
L-1W RECESSED CAN LIGHT (WET) FOCAL POINT FLCS3, RO, 1300L, 30K, FL, 120V, LD1, IC. TRIM & LED
MOD: LCS3,RO,AA,WH,WH
WHITE LED / 3000K WET RATED
SC-1 BATHROOM SCONCE CEDAR AND MOSS AUDREY 6INCH, OPAL GLOBE, HARDWIRED MATTE BLACK WITH BRASS G16 LED WET RATED
OFFICE
3
MECH
4
RECEPTION &
LOUNGE
1
OFFICE
6
CONFERENCE &
BREAKROOM
7
OFFICE
9
RESTROOM
10
OFFICE
11
OUTDOOR
LOUNGE
2
RESTROOM
5
COPY
8
CNC-1
CPT-2
CNC-1
CNC-1
CNC-1
CPT-2 CPT-1
CPT-1
CPT-1
CPT-1
FP-1
FP-1
FP-1
FP-1
PT-2
CNC-2
CNC-2
WD-1
TL-1
SEE ELEVATIONS
TL-3
TL-3
TL-1
PT-3
PT-3
PT-2
2
A810
2
A810
2
A810
1'-0"21'-0"1'-0"9'-9"1'-0"2
A810
2
A810
2
A810
12'-0"11'-6"4'-4"5'-2"WOOD BLINDS AT
ALL WINDOWS
A7004
Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:57:56 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057FINISH PLAN
A202
N
02'12'16' 4'8'
SCALE: 3/16" = 1'-0"
FINISH PLAN1
PLUMBING FIXTURES & ACCESSORIES LEGEND
MARK DESCRIPTION MFR / VENDOR MODEL / NAME COLOR / FINISH COMMENTS
SINK-1 KITCHEN SINK KOHLER VAULT, K-25939-NA, UNDERMOUNT LARGE SINGLE-BOWL STAINLESS 32" x 18-5/16" x 5-7/9"
FAUC-1 KITCHEN FAUCET KOHLER CRUE, K-22974, TOUCHLESS PULL-DOWN SINGLE HANDLE
KITCHEN FAUCET
VIBRANT STAINLESS
TOLIET-1 TOILET AMERICAN STANDARD 2989101.020, CADET 3 FLOWISE WHITE LEFT FRONT LEVER LOCATION
TOILET-2 TOILET AMERICAN STANDARD 2988813.020, CADET 3 FLOWISE WHITE RIGHT FRONT LEVER LOCATION
SINK-2 BATHROOM SINK GROHE EUROCUBE, 39656000, WALL MOUNT 24" 1-HOLE SINK ALPINE WHITE
PF-6 SINK SHROUD GROHE 39657000, WALL MOUNT SHROUD ALPINE WHITE
FAUC-2 BATHROOM FAUCET KOHLER K-13472-CP, GOOSENECK TOUCHLESS FAUCET VIBRANT STAINLESS
PF-7 FIXED SHOWER HEAD & CONTROL DELTA T217267-SS STAINLESS
PF-8 SHOWER CONTROL DELTA T17067-SS ARA, MONITOR 17 SERIES, VALVE ONLY STAINLESS PAIR WITH R10000 ROUGH-IN VALVE
PF-9 HAND HELD SHOWER DELTA 51799-SS-PR, UNIVERSAL SHOWERING H20KINETIC 3 SETTING,
SLIDE BAR HAND SHOWER, LUMICOAT STAINLESS
: 51799-SS-PR
VIBRANT STAINLESS
PA-1 TOILET PAPER DISPENSER DELTA 75950-SS, TRINSIC STAINLESS
PA-2 SEAT COVER DISPENSER BOBRICK B-221.MBLK, SURFACE MOUNTED SEAT-COVER DISPENSER MATTE BLACK
PA-3 SOAP DISPENSER DELTA 6746453, UME SOAP DISPENSER TALL BLACK
PA-7 WALL HOOK WEST ELM 4402687, SIN UNI WALL HOOK BLACK
PA-9 WALL SHELF - 24" WEST ELM 5022031, LINEAR BURNT WAX WOOD WALL SHELVES W/ JORDAN
BRACKETS
DARK BRONZE
PA-10 CURTAIN ROD BOBRICK B-207 X 72, SHOWER CURTAIN ROD W/ CONCEALED MOUNTING CHROME PLATED
PA-11 SHOWER SOAP DISPENSER SIMPLEHUMAN BT1034 SINGLE WALL MOUNT SOAP PUMP STAINLESS
PA-12 SHOWER FOLDING SEAT FREEDOM SHOWERS APFSSB-280150PT, FOLDING SHOWER BENCH, PHENOLIC
SLATTED TAK
TEAK
PA-13 GRAB BAR - 18" DELTA 41918, 18" ANGULAR MODERN DECORATIVE GRAB BAR MATTE BLACK
PA-14 GRAB BAR - 24" DELTA 41924, 24" ANGULAR MODERN DECORATIVE GRAB BAR MATTE BLACK
PA-15 GRAB BAR - 36" DELTA 41936, 36" ANGULAR MODERN DECORATIVE GRAB BAR MATTE BLACK
PA-16 GRAB BAR - 42" DELTA 41942, 42" ANGULAR MODERN DECORATIVE GRAB BAR MATTE BLACK
EQUIPMENT & APPLIANCE LEGEND
MARK DESCRIPTION MFR / VENDOR MODEL / NAME COLOR / FINISH COMMENTS
DISH FULLY INTEGRATED
DISHWASHER
MIELE G 5050 SCViI ACTIVE PLAM TO MATCH ADJACENT
CABINETS
FOIC, CONTRACTOR TO PROVIDE PLAM FACE PANEL
MICRO MICROWAVE TBD STAINLESS FOIC
REF REFRIGERATOR GE MODEL#: PWE23KYNFS STAINLESS FOIC
FINISH SCHEDULE
MARK DESCRIPTION VENDOR / MANUF MODEL SIZE LOCATION REMARKS CONTACTS
CNC-1 CONCRETE N/A N/A N/A SEE FINISH PLAN ARCHITECTURAL GRADE SMOOTH CONCRETE W/ CLEAR
COAT FINISH, LIGHT GRIND, PROVIDE MOCK-UP SAMPLE
FOR APPROVAL
CNC-2 CONCRETE N/A N/A N/A SEE FINISH PLAN ARCHITECTURAL GRADE SMOOTH CONCRETE W/ CLEAR
COAT FINISH, LIGHT GRIND, PROVIDE MOCK-UP SAMPLE
FOR APPROVAL
CPT-1 CARPET INTERFACE FRENCH SEAMS, 105607 LYON 25CM X 1 METE PLANK OFFICES ASHLAR INSTALLATION, INSTALL PER MANF INSTRUCTIONS
CPT-2 CARPET MILIKEN LAPIDUS, MANTLE, MAN132-171 SAPPHIRE 1 METER SQUARE MEETING &
RECEPTION
INSTALL PER MANF INSTRUCTIONS
FP-1 ACOUSTICAL PANEL TRACK-MOUNTED FABRIC
PANELS;
1" SQUARE EDGE BUTT JOINT, 1"
ACOUSTICAL FIBERGLASS SUBSTRATE W/ MIN. 0.80 NRC.
FABRIC:
CASAMANCE, LOUANGE, 3778 04 52, UNBACKED, 55"
WIDTH TRACK-MOUNTED FABRIC PANELS; 1/2" SQUARE
EDGE BUTT JOINT,
TACKABLE/ACOUSTICAL FIBERGLASS SUBSTRATE
PER FABRIC WIDTH OFFICES PROVIDE SHOP DRAWINGS PRIOR TO INSTALL. ALIGN
FABRIC PATTERN FROM PANEL TO PANEL. STAINLESS
COVERPLATES AT FP-1 LOCATIONS
MIR-1 WALL MIRROR WEST ELM STREAMLINE ROUNDED EDGE WALL MIRROR - BLACK 24"X36 RESTROOM
PLM-1 PLASTIC LAMINATE WILSONART ACORN VELVET ELM 15602 PER MANF BREAKROOM VERTICAL GRAIN
PLM-2 PLASTIC LAMINATE WILSONART SLATE VELVET 15507 PER MANF OFFICE
PT-1 PAINT BENJAMIN MOORE OR SIM COLOR TO MATCH: BENJAMIN MOORE, OC-21 WINTER
WHITE
N/A WALLS AND CEILINGS
U.O.N.
EGGSHELL AT WALLS AND FLAT AT CEILING
PT-2 PAINT (ACCENT) BENJAMIN MOORE OR SIM COLOR TO MATCH: BENJAMIN MOORE, HC-154 HALE
NAVY
N/A SEE ELEVATIONS EGGSHELL. STAINLESS COVERPLATES AT PT-2 LOCATIONS
FINISH SCHEDULE
MARK DESCRIPTION VENDOR / MANUF MODEL SIZE LOCATION REMARKS CONTACTS
PT-3 PAINT (ACCENT) BENJAMIN MOORE OR SIM COLOR TO MATCH: BENJAMIN MOORE, HC-154 HALE
NAVY
N/A RESTROOMS GLOSS. STAINLESS COVERPLATES AT PT-3 LOCATIONS
SS-1 SOLID SURFACE CAERSARSTONE 4001 FRESH CONCRETE 2CM BREAKROOM &
RECEPTION DESK
SS-2 SOLID SURFACE CAERSARSTONE 406 CLEAR SKIES 2CM OFFICE
TL-1 FLOOR TILE TBD PROVIDE ALLOWANCE FOR $8 PER SQFT 8" SQUARE RESTROOM
TL-3 FLOOR TILE TBD PROVIDE ALLOWANCE FOR $8 PER SQFT TBD RESTROOM
WD-1 WOOD TBD IPE WOOD DECKING 4" PLANKS EXTERIOR DECK
WD-2 WOOD SURFACING SOLUTIONS FLEXIBLE WOOD TAMBOUR PANELS, OAK, T438, 1" PANEL SIZE PER
MANF
RECEPTION DESK VERTICAL INSTALLATION
WD-3 WOOD OAK STAIN GRADE OAK, STAINED TO MATCH WD-2 4" WIDE RECEPTION DESK
WD-4 WOOD OAK STAIN GRADE OAK, STAINED TO MATCH WD-2 PER DRAWINGS RECEPTION SCREENS
WDB WOOD BASE PAINT GRADE HARD WOOD 1X4 ALL LOCATIONS PAINT TO MATCH WALL
NEW ADA RAMP. SLOPE 1:12 MAX
LANDING
5'-1"
LANDING
5'-0"
RAMP
10'-0"
UP3'-6"3
A500
0" AFF 10" AFF
36" CONTINUOUS HANDRAIL
RETURN TO FLOOR TYP 1'-0"7'-8"1 1/2" MIN
HANDRAILS TO HAVE CIRCULAR
CROSS SECTION, OUTSIDE
DIAMETER 1-1/4" MIN TO 2" MAX
UP
LANDING
5'-2"
RAMP
13'-0"
LANDING
5'-2"3'-11"0"AFF 19"AFF
19"AFF
EXISTING DECK
3'-6"4
A500
NEW ADA RAMP SPLOPE 1:12
MAX
36" CONTINUOUS HANDRAIL RETURN
TO FLOOR TYP 1'-0"1'-0"
HANDRAILS TO HAVE CIRCULAR
CROSS SECTION, OUTSIDE DIAMETER
1-1/4" MIN TO 2" MAX1 1/2" MIN1 1/2" MIN
AFF10"HANDRAIL TYP36"T
T
T T
TGAURDRAIL TYP42"RAILINGS CR LAURANCE ARS
200 SERIES RAILING SYSTEM,
MATTE BLACK, TYP
GLASS PANELS CR
LAURANCE ARS ALUMINUM
RAILING SYSTEM, TYP
T
4"LANDING ALIGNED
WITH (E) GRADE
C.I.P. CONC, TYP
MAX SLOPE 1:12, TYP
COMPACTED
GRAVEL BASE, TYP
#5 AT 48" O.C., TYP
#5 CONTINUOS, TYP
C.I.P. CONC, TYP
LANDING ALIGNED
WITH (E) GRADE HANDRAIL TYP36"MAX SLOPE 1:12, TYP
T
T
T
T
T
T
GAURDRAIL TYP42"4"2"4"RAILINGS CR LAURANCE
ARS 200 SERIES
RAILING SYSTEM,
MATTE BLACK, TYP
GLASS PANELS CR
LAURANCE ARS
ALUMINUM RAILING
SYSTEM, TYP
T
COMPACTED
GRAVEL BASE, TYP
#5 AT 48" O.C., TYP
#5 CONTINUOS, TYP
1. HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH RAMP RUN.
GRIPPING SURFACE SHALL BE CONTINUOUS, WITHOUT INTERRUPTION BY NEWEL
POSTS, OTHER CONTSTRUCTION ELEMENTS, OR OBSTRUCTIONS.
2. HANDRAILS SHALL BE AT CONSISTENT HEIGHT ABOVE RAMP SURFACE AND WALKING
SURFACES.
3. CLEARANCE BETWEEN HANDRAIL GRIPPING SURFACE AND ADJACENT SURFACES SHALL
BE 1-1/2" MIN.
4. HANDRAILS WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF
1-1/4" MIN TO 2" MAXIUMUM.
5. HANDRAILS, AND ANY WALL OR OTHER SURFACES ADJACTENT TO THEM, SHALL BE FREE
OF ANY SHARP OR ABRASIVE EELEMENTS. EDGES SHALL BE ROUNDED.
6. HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
HANDRAIL & GUARDRAIL NOTES
Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:57:57 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057EXTERIOR RAMPS
A500
SCALE: 1/2" = 1'-0"
ENLARGED PLAN - EXTERIOR ENTANCE RAMP1 SCALE: 1/2" = 1'-0"
ENLARGED PLAN - EXTERIOR DECK RAMP2
SCALE: 1/2" = 1'-0"
SECTION - EXTERIOR ENTANCE RAMP3 SCALE: 1/2" = 1'-0"
SECTION - EXTERIOR DECK RAMP4
N N
BASE CABINET WITH
COUNTER 34"AFF
SINKDISH
2'-0"30"X48" CLEAR
FLOOR AREA FOR
SINK &
DISHWASHER
A700
1
A700
3
A7002
CONFERENCE &
BREAKROOM
7
REF
A7004
OFFICE
9
COPY
8
UPPER CABINETS AND SHELVES ABOVE2'-5"30"X48" CLEAR
FLOOR AREA FOR
REFRIGERATOR2'-10"2'-2"2'-8"6'-8"MIN1'-0"PLM-1
CABINET DOORS TYP
SS-1ALIGN
END PANEL
END PANEL
TL-3
ALIGN W/ EDGE OF DWOPEN SHELVING
PT-1
T R
3
A900
1
A900
1
A900
2
A900
5
A900
10"10"4
A900
T ALIGN REF
DISHWASHER
SINK-1
ALIGN
6
A900
FAUC-1
3'-0"1'-3"1'-3"
PLM-1
VERIFY REQ'D R.O.
2'-1"1'-3"1"
VERIFY REQ'D R.O.
3'-0"1"1'-6"1"
MICRO
MOCKETT, DP129 SERIES -
ROUND TOP DRAWER PULL,
SATIN STAINLESS STEEL, TYP
2" BLACK ACRYLIC LETTERS.
USE INDUSTRIAL VELCRO TO
ATTACH TO CABINETS
PLM-1
TL-3
PLM-1
RECYCLE PULLOUT
TRASH PULLOUT 1'-0"2'-8 1/2" 3'-11 1/2"
WDB
PLM-1
CONTRACTOR TO
PROVIDE BACKING
60" MONITOR FOIC
PROVIDE POWER AND DATA
PER REQUIREMENTS,
CORDINATE WITH AV
CENTERED ON CONF TABLE
5'-11"5'-0"CLCL
WDB
SS-2
PLM-2
PT-2
2
A900
SIM
DRAWER PULLS: MOCKETT,
DP269 - 3" TAB DRAWER PULL,
SATIN NICKEL. TYP
3'-3"3'-3"3'-3"END PANEL
1"9"4"4"7"7"7"1"6"1"1'-3"PLM-2
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
10"1'-0"FILLER
1"2'-0"3'-3"
5
A900
4
A900
5'-0"PLM-1
PRINTER
WDB
Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:57:58 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057INTERIOR
ELEVATIONS -
CONFERENCE &
OFFICE
A700
SCALE: 1/2" = 1'-0"
CONFERENCE ROOM 7 - PLAN5
SCALE: 1/2" = 1'-0"
CONFERENCE 7 - KITCHENETTE1
SCALE: 1/2" = 1'-0"
CONFERENCE 7 - WALL MONITOR2 SCALE: 1/2" = 1'-0"
OFFICE 9 - CASEWORK3
SCALE: 1/2" = 1'-0"
COPY 8 - UPPER CASEWORK4
N
A701 2
A701
7
RECEPTION &
LOUNGE
1
A701
3
A701 1
8
A701
A701
4
A701 2
SS-1 1'-10"1'-10"
1'-10"EQ EQ
METAL GROMMETS IN DESK
SURFACE. MOCKETT: PS-1C - 1-3/4"
FLUSH MOUNT DESK GROMMET, 2
SLOTS, SATIN NICKEL
CONVENIENCE OUTLET IN DESK SURFACE: MOCKETT,
PCS49A/USBAC-95 - RECTANGULAR POWER/USBA+C
ELECTRICAL IN CHASE WALL 3'-0"3'-6"
8
A701
3 1/2" 1'-3" 1'-3" 1'-6" 3/4" FP 7'-11 1/4"
SS-1
LOCKABLE DOORS
AND DRAWERS, TYP 1'-0" 6" 6"1'-0" 1'-0"4" 2'-0" 1 1/2"
PLM-2
DRAWER PULLS: MOCKETT,
DP254B - 7" TAB DRAWER PULL,
ALUMNINUM. TYP
FILE DRAWERS
8
A701
3a
WD-2
WD-3
SS-1
RENTON AIRPORT
5" BLACK ACYRILIC
LETTERS PIN MOUNTED 6"1 1/2"2'-1"3"2'-4"EQ EQ
3'-2"SCREENS IN FULLY
OPEN POSITION
WD-2
WD-3
SS-1
2'-5"
4'-1" TYP
8'-2" TYP
16'-3"
9
A701
FLOOR MOUNTED KEY LOCK TO SECURE
PERFORATED PANEL IN PLACE. VENDOR TO
COORDINATE REQ W / OWNER AND ARCH
CUSTOM SCREENS.
PERFORATED 1" THICK
MDF. PAINT MDF
SEE RENDERINGS ON
A701-5 FOR DESIGN
INTENT.
ARCHITECT TO PROVIDE
CAD DRAWINGS FOR
FABRICATION. PROVIDE
AN ALLOWNACE OF
$7,000 FOR THE PANELS.
WD-4
PT-2
WOOD FRAMES
TYP
3"TYP3"SCREENS TO HAVE FLOOR GLIDES
4'-1"
FLOOR MOUNTED KEY LOCK TO SECURE
PERFORATED PANEL IN PLACE. VENDOR TO
COORDINATE REQ W / OWNER AND ARCH
CUSTOM SCREENS.
PERFORATED 1" THICK
MDF. PAINT MDF
SEE RENDERINGS ON
A701-5 FOR DESIGN
INTENT.
WD-4
PT-2
WOOD FRAMES
WDB
ELECTRICAL IN CHASE
WALL
SOLID SURFACE COUNTER
PER ELEVATIONS
1 1/2"1"
3"
CLEAR
2'-0"
SOLID SURFACE SCREEN
WOOD TAMBOURS APPLIED TO
MDF PER MANF INSTRUCTIONS.
PROVIDE WOOD FILLER TO
MATCH TAMBOUR FINISH AT
NAIL HOLES.
1"3"2'-1"
PERFORATED SCREENS
FOR REFERENCE
SLIDING SCREEN
SHIM
1x TRIM, PT TO MATCH DOOR3/8"RENDERING FOR REFERENCE ONLY TO SHOW SCREEN
INTENTION, REFER TO DRAWINGS FOR INFORMATION
Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:57:59 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057INTERIOR
ELEVATIONS -
RECEPTION
A701
SCALE: 1/2" = 1'-0"
RECEPTION PLAN6
SCALE: 1/2" = 1'-0"
RECEPTION CASEWORK - INTERIOR7 SCALE: 1/2" = 1'-0"
RECEPTION CASEWORK - LONG4 SCALE: 1/2" = 1'-0"
RECEPTION CASEWORK - SHORT2
SCALE: 1/2" = 1'-0"
RECEPTION SCREEN - LONG3 SCALE: 1/2" = 1'-0"
RECEPTION SCREEN - SHORT1
SCALE: 1" = 1'-0"
RECEPTION DESK - SECTION8SCALE: 3" = 1'-0"
SLIDING SCREEN TRACK DETAIL9 SCALE: 1 1/2" = 1'-0"
RECEPTION SCREENS5NOT TO SCALE, FOR REFERENCE ONLY
N
RESTROOM
5
ø 5' - 0"5' - 0"56"1' - 6"SEE 5/A102 FOR GRAB BAR AND ACCESSORY LOCATIONS
30"X48" CLEAR
FLOOR AREA AT
LAVATORY
WALL MOUNTED SINK
A702
11
7
6
12
RESTROOM
10 2'-9"1' - 6"
5'-0"56"2' - 6"
30"X48" CLEAR
FLOOR AREA AT
LAVATORY
T SHAPE TURNING
CLEARANCE 3' - 0"2' - 0"12"3' - 0"
WALL MOUNTED SINK
A702
1
4
85 A702 92'-6"1' - 3 3/4"
10
5'-0" TO FACE OF FINISH
1'-3"1"1"DRAIN ALONG
WALL 2% SLOPETO DRAIN60" X 30" CLEAR
FLOOR AREA AT
SHOWER
2'-11"3'-6"5"3"3'-0"4"2'-10"PT-3
4'-0"MIR-1
5'-6"6"
SC-1
TOILET-1
SINK-2
PF-6
FAUC-2
TL-1
PA-3
PA-2
SPACER REQUIRED
BEHIND TOP OF GRAB
BAR TO MATCH TILE
THICKNESS
2'-0" MIN 1'-0" MIN
PA-16
WDB
3'-4"3'-4"3'-6"1'-0"
8"3"2'-11"PA-13
PA-16
PA-1
TL-1
WDB
5
4'-0"2'-4"
10"1'-0"TO TOP OF HOOK3'-7"PA-9
PA-7
TL-1
WDB
PT-3
TL-1
WDB
PT-4
WDB 4'-0"TO TOP OF HOOK3'-7"2'-7"
1'-0"1'-1"
1'-0"1'-0"TO TOP OF HOOK3'-7"PA-9
PA-7PA-7
10
TL-1
WDB
3'-6"1'-0"
8"3"4'-0"PT-3
EXISTING WINDOW
TL-1
PA-16
PA-1
WDB
3'-6"5"2'-11"3'-0"6"1'-6"3'-10"3'-2"1'-4"7'-0"2'-10"4'-0"FOLDING SHOWER SEAT
TL-1 TL-1
PT-3
PT-3
MIR-1
CL
6"6"
CENTER MIRROR ON SINK
VIF NOTIFY ARCH W/ DISCREPANCY
7"
SC-1
5'-7"SC-1
TOILET-2
PA-15
SINK-2
PF-6
FAUC-2 PA-3
PA-2
PA-16
1'-0" MIN 2'-0" MAX
WDB
PF-8 PF-9
2'-2"
3"2'-0"5"1'-6"2'-11"10
PA-14
PA-13
TL-13'-10"6'-7"EQ EQ
PF-7
PF-7
7'-0"6'-11"1'-6"PA-12
TL-1
Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:58:03 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057INTERIOR
ELEVATIONS -
RESTROOMS
A702
SCALE: 1/2" = 1'-0"
ENLARGED PLAN - ADA RESTROOM 53SCALE: 1/2" = 1'-0"
ENLARGED PLAN - RESTROOM 102
SCALE: 1/2" = 1'-0"
RESTROOM 5 - NORTH7
SCALE: 1/2" = 1'-0"
RESTROOM 5 - EAST11 SCALE: 1/2" = 1'-0"
RESTROOM 5 - SOUTH12
SCALE: 1/2" = 1'-0"
RESTROOM 5 - WEST6
SCALE: 1/2" = 1'-0"
RESTROOM 10 - EAST1
SCALE: 1/2" = 1'-0"
RESTROOM 10 - NORTH8
SCALE: 1/2" = 1'-0"
RESTROOM 10 - SOUTH5SCALE: 1/2" = 1'-0"
RESTROOM 10 - WEST4
SCALE: 1/2" = 1'-0"
RESTROOM 10 - SHOWER9 SCALE: 1/2" = 1'-0"
RESTROOM 10 - SHOWER SEAT10
N N
PTD/WR
TPD
ABBREVIATIONS
ACC.ACCESSIBLE
CH COAT HOOK
CT CERAMIC TILE
DD DIAPER DISPENSER
DR DIAPER RECEPTACLE
FD FLOOR DRAIN
FS FIXED SHELF
FUS FOLDING UTILITY SHELF
GB GRAB BAR
PTD PAPER TOWER DISPENSER
PTN PARTITION
SCD SEAT COVER DISPENSER
SD SOAP DISPENSER
SND SANITARY NAPKIN DISPOSAL
SNV SANITARY NAPKIN VENDOR
TB TOWEL BAR
TPD TOILET PAPER DISPENSER
WR WASTE RECEPTACLE
PTD/WR PAPER TOWEL DISP./
WASTE RECEPTACLE
SNV
PTD / HD
54"48" MAXTYPICAL NON-ACC.ACCESSIBLE6" REACH DEPTH
40"PTD / HD
48" MAXPAPER TOWEL DISPENSER
AND HAND DRYERPER 309.3, 308PER 603.6MAX REACH
DEPTH
MAX REACH
HEIGHT
0.5"
48"
2"
46"
5" 6" 9" 11"
42" 40" 36" 34"
TABLE 603.6
PER TABLE
SD
HD HAND DRYER
48" MAX TO OPERABLE PART OF UNIT
PROVIDED 1/2" MAX PROJECTION OF
UNIT FROM WALL - TABLE 603.648" MAXWALL MOUNTED ACCESSORIES
CHT CHANGING TABLE
COAT
HOOK
42" MAX
24" MIN 1 1/2" MINWALL MOUNTED PAPER
TOWEL DISPENSER48" MAX12"24" MIN
36" MAX
MIN7"- 9"
DISPENSER
OUTLET
LOCATION
(SHADED)
PREFERRED
LOCATION
TPD
42" MAX
24" MIN
RECESSED PAPER
TOWEL DISPENSER48" MAX36" MAX
DISPENSER
OUTLET
LOCATION
(SHADED)
24" MIN
CDU 1 1/2" MINSCD
SCD
48" MAX30"18"MIN18"MINSEAT COVER
DISPENSER REAR WALL
SEAT COVER
DISPENSER SIDE WALL
FIGURE 604.7
FIGURE 604.7
CDU COMBINATION DISPENSER UNIT
SIDE GRAB BARS REAR GRAB BARS
WATER CLOSET33" - 36"54" MIN
42" MIN12" MAX
39" - 41"CL
39" - 41"18" MIN33" - 36"36" MIN 6" MAX
42" MIN
16" - 18"
CL17" - 19"34"48" MAX20" MAX
34"44" MAX22"- 25"48" MAX15" MIN48" MAX34"10" MAX 46" MAX34"10.1"- 24"
REACH
AREA
REACH
AREA
REACH
AREA
OBSTRUCTED SIDE REACH
FIGURE 308.3.2
REACH
AREA
REACH
AREA
48" MAX15" MIN10" MAX
REACH
AREA
UNOBSTRUCTED SIDE
REACH
FIGURE 308.3.1
UNOBSTRUCTED
FORWARD REACH
FIGURE 308.3.1
OBSTRUCTED FORWARD REACH
FIGURE 308.3.2
FAUCET PER
WAC51-40,1106.7.5.
MIRROR
TO ADJ.
WALL
INSULATE OR COVER PER WAC 11-40,
1106.7.4. REFER TO PLUMBING SPECS
27"34" MAX40" MAX18" MIN
MINT.O. HIGHEST POINT OF LAV. RIM
OR COUNTER
B.O. MIRROR REFLECTIVE SURFACE
FIGURE C606.2 (a)
CL
27"11" 6"10"8"
ADA KNEE CLEARENCE
1. ACCESSORIES TO BE MOUNTED PER 3/A6.1.
2. LAVS AND COUNTERS TO COMPLY WITH ACCESSIBLE REACH LIMITS AND ACCESSIBLE VANITY HEIGHTS.
3. 5'-0" TURN RADIUS AND ALL CLEAR FLOOR AREAS SHALL BE MEASURED FROM FLOOR TO 27".
4. REFER TO PLUMBING FIXTURE SCHEDULE FOR SPECIFICATIONS OF ALL PLUMBING FIXTURES
(LAVATORIES, WATER CLOSETS, URINALS, SHOWERS, DRAINS).
5. REFER TO ACCESSORIES SCHEDULE FOR ADDITIONAL SCOPE AND SIGNAGE SCOPE.
6. PER IBC REQUIREMENTS PROVIDE SMOOTH, NON-ABSORBENT MATERIAL UP TO 4FT AFF AT WET WALLS
ADJACENT TO TOILET.
GENERAL RESTROOM NOTES
Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:58:04 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057ACCESSIBILITY
PLANS & DETAILS
A710
SCALE: 1/4" = 1'-0"
ACCESSIBLE ACCESSORY MOUNTING HEIGHTS3
SCALE: 1/4" = 1'-0"
ACCESSIBLE REACH LIMITS2 SCALE: 1/4" = 1'-0"
ACCESSIBLE VANITY HEIGHTS1
DOOR LEGEND
MATERIAL KEY
HCW HOLLOW CORE WOOD
SOLID WOOD CORE
HOLLOW METAL
WOOD/ GLASS
METAL/ GLASS
METAL
SWC
HM
WG
MG
MTL
GLASSGL
ALUMINUMALUM
FINISH KEY
PAINTPT
STAINST
STAINLESS STEELSST
FACTORY FINISHF FIN
WOOD VENEERWV
WOODWD
VINYLVIN
INSULATED HOLLOW METALIHM
WOOD CARDBOARD COREWCC
FIBERGLASS/ GLASSFG
HANDLE
FIRE STROBE
WALL BASE
RECEPTACLE
TELE/DATA
COVERPLATE
FINISHED FLOOR
CARD READER
1.
2.
DOOR & FRAME
PER SCHEDULE
SWITCHPLATE -GANG
PLATE AS POSSIBLE
THERMOSTAT, VRFY
LOCATION w/ MECH'L
DWGS
UNLESS SPECIFICALLY DIMENSIONED LOCATE ALL TELEPHONE & ELECTRICAL WALL OUTLETS & SWITCH
PLATES AT THE NEAREST STUD.
PROVIDE CLEAR FLOOR SPACE THAT ALLOWS A FORWARD OR SIDE APPROACH IN COMPLIANCE WITH
1CC/ ANSI A117.1 -2003 ADA GUIDELINES AT ALL CONTROLS & HARDWARE.
FIRE
EXTINGUISHER
CAB. PER BLDG.
STANDARD
EXIT SIGN: PROVIDE
PENDANT WHERE CLG.
HUNG OR STRUCTURE
EXCEEDS 8'-6"AFF.6'-8"CL
6"4'-0"TO OF TRIM3'-4"CL6"1'-6"HARDWARE GROUPS
1 LOCKSET
- 3X BUTT HINGES
- 1X LEVER LOCKSET
- 1X WALL STOP
2 PRIVACY LOCKSET (NO INDICATOR)
- 3X BUTT HINGES
- 1X PRIVACY LOCKSET
- 1X LEVER CLASSROOM LOCKSET
- 1X WALL STOP
- 1X ACOUSTICAL SWEEP
- PERIMETER ACOUSTICAL BULB SEAL
3 PRIVACY LOCKSET
- 3X BUTT PASSAGE
- 1X PRIVACY LOCK \SET WITH
OCCUPANCY INDICATOR
- 1X WALL STOP
- 1X ACOUSTICAL SWEEP
- PERIMETER ACOUSTICAL BULB SEAL
-1X MOP PLATE 10" X 27" BRONZE FINISH
4 PRIVACY LOCKSET
- 3X BUTT PASSAGE
- LOCKABLE DROP BOLTS -
PROGRESSIVE HARDWARE CO INC.
ITEM NO. R1000, BRONZE FINISH
- 1X WALL STOP
1.ALL SWING DOORS TO BE LOCATED 4" OFF ADJACENT PARTITIONS AT HINGE SIDE
U.O.N.
2. REFER TO PARTITION TYPES FOR JAMB THICKNESS.
3. ALL DOORS ALLOW EGRESS IN THE DIRECTION OF EGRESS TRAVEL. ALL DOORS IN
THE MEANS OF EGRESS SHALL BE SINGLE ACTION RELEASE & SHALL NOT REQUIRE THE
USE OF A KEY OR SPECIAL KNOWLEDGE FROM EGRESS SIDE. NO THUMB LATCHES OR
KEYED CYLINDER DEAD BOLTS ALLOWED ON ANY DOORS IN EGRESS PATH.
4. UNDERCUT DOORS TO CLEAR THE TOP OF FINISH FLOORS, AS APPLICABLE, BY 1/4"
MAXIMUM. VERIFY FLOOR CONDITIONS.
5. ALL DOORS SHALL HAVE 1'-6" CLR ON STRIKE/PULL SIDE OF DOOR.
7. ALL DOOR HARDWARE TO COMPLY WITH CURRNENT ADA.
8. VERIFY ALL HARDWARE & LOCKING REQ'S w/OWNER PRIOR TO ORDERING
9. CONFIRM KEYWAY REQUIREMENTS WITH OWNER.
10. ALL LEVER SETS TO BE SARGENT STUDIO / COLLECTION CENTRO SERIES / MD / CR
ROSE, US10B FINISH
11. ANY DOOR HARDWARE, LOCKSET OR LATCH SET THAT IS BEING REUSED SHALL BE
TESTED FOR PROPER OPERATION AND ANY REPAIRS NECESSARY SHALL BE MADE
PRIOR TO OCCUPANCY. ALL SWING DOORS SHALL BE ADJUSTED TO MEET
REQUIREMENT FOR MAX. 5 LB. PRESSURE FORCE TO OPERATE DOOR.
DOOR & HARDWARE NOTES
12. NFRC U VALUES FOR ALL GLAZED EXTERIOR SLIDING DOOR SYSTEMS IS U=.30
MAX. U=.20 MAX AT ALL SWINGING AND PIVOTING EXTERIOR DOORS
13. CALCULATE INSTALLATION COSTS OF DOOR HARDWARE SEPARATELY
14.DIMENSIONS FOR SWINGING, PIVOTING, AND ALL INTERIOR DOORS ARE
APPROXIMATE ACTUAL DOOR SIZES. VERIFY DOOR SIZES FOR ALIGNMENT OF
ADJACENT DOOR AND WINDOW HEADERS AND JAMBS
15. DIMENSIONS FOR EXTERIOR MULTI-PANEL SLIDING DOORS ARE FOR ROUGH
OPENING. T=TEMPERED GLAZING
WD. DR. PER SCHED.
1/2" WD. SHIM
WD. FRAME; ROUTE
TO RECEIVE GWB
R.O.3/4"3/4"5/8"PER WALL TYPE5/8"1 3/4"2 1/2"1/4"
• SINGLE HINGED DOOR
• 1 3/4" SOLID WOOD STILE & RAIL
• 1/4" TEMPERED GLASS INSET
• WOOD VENEER
2
A800
2
A800
3'-0"7'-0"3'-0"
T
A
• SINGLE HINGED DOOR
• 1 3/4" SOLID WOOD STILE & RAIL
• WOOD VENEER
B C
T
3'-0"
6"6"6"10"8"6"1'-9"6"• SINGLE HINGED DOOR
• 1 3/4" SOLID WOOD STILE & RAIL
• 1/4" TEMPERED GLASS INSET
• WOOD VENEER
3'-0"7'-0"7'-0"T T6"10"6"6"
3'-0" 3'-0"7'-0"D
• DOUBLE HINGED DOOR
• 1 3/4" SOLID WOOD STILE & RAIL
• 1/4" TEMPERED GLASS INSET
• WOOD VENEER
2
A800
Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:58:04 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057DOOR AND
WINDOW
SCHEDULE &
DETAILS
A800
DOOR AND FRAME SCHEDULE
MARK TYPE
DOOR FRAME
FIRE
RATING
HDW
SET NOTES LOCATIONMATL FIN
SIZE MAT
L FINWIDTH HEIGHT THK
FINISH FLOOR
1a C WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 ELECTRIFIED, EXTERIOR DOOR, U FACTOR PER CODE REQ RECEPTION & LOUNGE
1b A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 ELECTRIFIED HALLWAY
1c A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 ELECTRIFIED, EXTERIOR DOOR, U FACTOR PER CODE REQ RECEPTION & LOUNGE
3a A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 RECEPTION & LOUNGE
3b A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 OFFICE
3c D WD CLR 6' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 4 OFFICE
5 B WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 3 RESTROOM
6 A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 OFFICE
7 A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 2 CONFERENCE & BREAKROOM
9 A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 OFFICE
10 B WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 3 RESTROOM
11 A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 OFFICE
SCALE: 1/2" = 1'-0"
TYPICAL MOUNTING HEIGHTS1
SCALE: 3" = 1'-0"
JAMB DETAIL2
TYPE A UL #423 1HR
*STC: 42 ACOUSTIC
(1) LAYER
GYPSUM WALL
BOARD (GWB)
SOUND ATTENUATION
BLANKET*
STEEL STUD
STUD SIZE KEY
0 HAT CHANNEL
1 1 5/8"
2 2 1/2"
3 3 5/8"
4 4"
6 6"
8 8"
10 10"
1. GWB ON 25 GAUGE MTL STUDS @ 16" O.C. TYPICAL UON. INSTALL STEEL FRAMING TO
COMPLY w/ ASTM C 754 & w/ ASTM C 840 REQ'S THAT APPLY TO FRAMING INSTALLATION.
2. ALL RATED & ACOUSTICAL PARTITION TO HAVE 5/8" TYPE "X" GWB TYPICAL UON.
3. PARTITION TYPES ARE ASSUMED TO END AT INTERSECTING WALLS WHERE RATED
PARTITIONS INTERSECT NON-RATED PARTITIONS. THE RATED PARTITION IS ASSUMED TO
CONTINUE UNINTERRUPTED.
4. ALL FIRE RATED AND SMOKE ASSEMBLY PARTITIONS EXTEND TO STRUCTURE, UON.
5. ALL THROUGH PENETRATIONS OF FIRE-RATED ASSEMBLIES SHALL BE INSTALLED AS
TESTED PER CODE.
6. APPLY OR PATCH FIREPROOFING TO DECK ABOVE (WHERE OCCURS) AFTER
INSTALLATION OF TOP TRACK OR MOUNTING PLATES.
7. APPLY ACOUSTIC SEALANT (WHERE OCCURS) TO FIREPROOFING (WHERE OCCURS) OR
TO B.O. STRUCTURE.
8. FOR PARTITIONS EXTENDING TO CEILING OR ABOVE, PROVIDE BRACING ABOVE CEILING
AS REQUIRED TO LIMIT DEFLECTION TO SPECIFIED ALLOWANCES.
9. ALL ACOUSTICAL PARTITIONS HAVE FULL WALL CAVITY R-11 BATT MIN.
PARTITION TAG LEGENDGENERAL PARTITION NOTES
1. ALL ACOUSTICAL PARTITIONS HAVE FULL WALL CAVITY R-11 BATT MIN.
2. STAGGER JOINTS ON ALL MULTIPLE LAYERS OF GYPSUM BOARD.
3. ON WALLS TALLER THAN 10'-0" APPLY ONE LAYER HORIZONTALLY AND THE OTHER
VERTICALLY. CONTRACTOR TO DETERMINE THE ORDER OF VERTICAL/ HORIZONTAL
PLACEMENT.
4. CAULK ALONG BOTH SIDES OF THE PERIMETER WITH A NON-HARDENING SILICONE
MASTIC.
5. AVOID BACK-TO-BACK OUTLETS. CAULK ALL OPENINGS IN ELECTRICAL BOXES. A
MINIMUM OFFSET OF 18" WITH AT LEAST ONE STUD BETWEEN THE BOXES IS
REQUIRED BETWEEN ELECTRICAL BOXES ON OPPOSITE SIDES OF A COMMON
PARTITION WALL.
6. WHERE A DOUBLE ROW OF STUDS ARE USED MAKE NO CONNECTION BETWEEN THE
ROWS.
7. WHERE A SOUND RETARDANT PARTITION ABUTS PERPENDICULARLY TO A
CONTINUOUS GYPSUM BOARD PARTITION, INTERRUPT THE GYPSUM BOARD AT THE
POINT OF INTERSECTION AND CAULK THE JOINT LIBERALLY. DO NOT CONTINUE THE
GYPSUM BOARD BEHIND THE INTERSECTION STUD.
8. ALL OPENINGS AROUND DUCT OR PIPE PENETRATIONS SHALL BE SEALED WITH A NON-
HARDENING SILICONE MASTIC
ACOUSTICAL PARTITION NOTES
EXISTING STRUCT,
HEIGHT VARIES VIF.
BRACING
SUSPENDED
CLNG WHERE
OCCURS
PARTIAL
HEIGHT
WALL
REFER TO ELEV's
REFER TO RCP's
a b c d e6"6"f
NON-
RATED
(REFER TO PLANS, NOT ALL CONFIGURATIONS USED)
CONC
SLAB
PARTITION TAG LEGEND
PARTITION TYPE
CONFIGURATION (REFER TO
KEY)
STUD SIZE DESIGNATION
(REFER TO KEY)
PARTITION HEIGHT/HEAD
CONDITION (REFER TO KEY)
# DESIGNATES FIRE-RATING
A3a ' ' DESIGNATES
ACOUSTICAL PARTITION
2 XX10. ACOUSTICAL PARTITIONS TO BE CAULKED & SEALED AIRTIGHT.
11. INSTALL (DENS-SHIELD OR EQ) TILE BACKER BOARD AT ALL INTERIOR TILE FINISHES
TYPICAL, SEE INTERIOR ELEVATIONS FOR LOCATIONS.
12. PROVIDE 5/8" WATER RESISTANT DRYWALL AT ANY WET WALLS.
13. WHEN METAL FRAMING CONTINUES PAST INTERMEDIATE STRUCTURES -AS IN
MULTISTORY STAIR ENCLOSURES AND SIMILAR CONDITIONS -ATTACHMENT TO
INTERMEDIATE STRUCTURE SHALL BE WITH A SLOTTED CONNECTION OR OTHER MEANS
SO THAT STRUCTURAL DEFLECTION WILL NOT TRANSFER LOADS TO METAL FRAMING.
14. CUT STUDS 1/2" SHORT TO ALLOW 1/2" DEFLECTION & PROVIDE NESTED TRACK OR
SLOTTED TRACK TO ALLOW 1/2" DEFLECTION.
15. HOLD FINISH MATERIALS 1/2" SHORT OF STRUCTURE ABOVE. DO NOT FASTEN TO TOP
TRACK. FASTEN INTO STUDS ONLY.
16. ALL EXISTING SHELL AND CORE WALLS IN TENANT SPACE TO BE FINISHED PER FINISH
SCHEDULE.
ACOUSTIC SEALANT AT
PERIMETER & AT ALL
PENETRATIONS
BOTTOM TRACK SET w/ FOAM TAPE
POWER FASTENER AT 24" O.C.
WITH 100 # PULLOUT MIN.
BASE PER SCHEDULE
GWB TO STRUCT OR CLNG ABV:
-DEEP LEG TRACK ASSEMBLY
-PROVIDE ACOUSTIC SEALANT FROM
T.O. GWB TO STRUCT.
-CONTINUE ACOUSTIC BATT TO STRUCT.
SUSPENDED CLNG PER PLAN
BATT INSUL1/2" MAXWD. BASE PER
SCHEDULE; SCRIBE
TO FLOOR
WALL ASSEMBLY
PER TYPE
F.F. PER SCHEDULE
1X4 HARD WOOD
WDB DIM.PT.DIM.PT.FUTURA BEVEL CAP
(LVT 405 EBR2)
CARPET SUBSTRATE
EXISTING
FINISH FLOOR
Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:58:05 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057INTERIOR WALL
ASSEMBLIES &
DETAILS
A810
1 1/2" = 1'-0"A810
4 PARTITION ATTACHMENT
SCALE: 6" = 1'-0"
WOOD BASE1 SCALE: 12" = 1'-0"
GLUE DOWN CARPET TO EXISTING CONC2
MELAMINE ON 1/2" SUBSTRATE BACK
F.F.
MELAMINE ON 1/2" SUBSTRATE BACK
CABINET SIDES AND BOTTOM:
MELAMINE ON 3/4" SUBSTRATE
BLACK MELAMINE ON 3/4"
SUBSTRATE ADJ. SHELF
BRACKET HOLES AT 2" O.C.
VERTICALLY
CABINET PULL AS SCHEDULED, SOFT
CLOSE
DOOR FRONTS; PLASTIC
LAMINET STILE AND RAIL 2 1/2",
DRAWER SIZES PER ELEVATIONS
PER ELEVATIONSDRAWERS; MELAMINE
INTERIOR FINISH W/ HEAVY
DUTY, SOFT CLOSE, FULL
EXTENSION SLIDES, TYP.
DRWR. FRONTS; WOOD VENEER
STILE AND RAIL 2 1/2",
DRAWER SIZES PER ELEVATIONS
CABINET SIDES AND BOTTOM:
MELAMINE ON 3/4" SUBSTRATE
WOOD BASE TO MATCH CABINET
DRAWERS; MELAMINE
INTERIOR FINISH W/ HEAVY
DUTY, SOFT CLOSE, FULL
EXTENSION SLIDES, TYP.
DRWR. FRONTS; WOOD VENEER
STILE AND RAIL 2 1/2",
DRAWER SIZES PER ELEVATIONS
MELAMINE ON 1/2" SUBSTRATE
BACK
CABINET SIDES AND BOTTOM:
MELAMINE ON 3/4" SUBSTRATE
WOOD BASE TO MATCH CABINET
F.F.
PER PLAN
1 1/2"1 1/2"STONE OR SOLID SURFACE
COUNTER PER ELEVATIONS
CAULK TO WALL
BACKSPLASH MATERIAL PER ELEVATIONS
APPLIED TRIM WHERE WOOD
VENEER WALLCOVERING
OCCURS
F.F.
SIDES AND BOTTOM:
MELAMINE ON 3/4" SUBSTRATE
MELAMINE ON 1/2"
SUBSTRATE BACK
SOLID SURFACE COUNTER
AND NOSE ON 1" PLYWD.
PULL-OUT FULL-HEIGHT
DRAWER ON HEAVY DUTY
FULL EXTENSION DRWR.
SLIDE; SOFT CLOSE
MECHANISM
PLAM ON 3/4" SUBSTRATE
BASE TO MATCH CAB.
BACKSPLASH PER
ELEVATIONS
PER PLAN
1"1 1/2"4"2 1/2"PER ELEV.CABINET HARDWARE TO BE
SELECTED BY ARCHITECT
DOOR FRONTS; WOOD VENEER
STILE AND RAIL 2 1/2",
DRAWER SIZES PER ELEVATIONS
2"2"PER ELEVATIONS2"PER ELEVATIONSMIN
1'-2"WD-1 ON (3) 1/2" SUBSTRATE ALL
SIDES
1/2" X 9" STEEL SUPPORT ROD
WELDED TO CONCEALED 4" X 3 1/2"
X 1/4" STEEL PLATE MECHANICALLY
FASTENED TO BLOCKING
UNDER CABINET LIGHT
FIXTURE PER ELEVATION3/4"12" CLEAR 3/4"
MELAMINE ON 1/4"
SUBSTRATE BACK
CAB. FRONTS; PLAM ON 3/4"
SUBSTRATE ALL SURFACES
MELAMINE ON 3/4"
SUBSTRATE
@ ALL INTERIOR
SURFACES
UNDER CABINET LIGHT
FIXTURE1/2"LINE OF CEILING
VALENCE TRIM, TYP
PER ELEVATIONSPER ELEVATIONS2 1/2"NOTE: SEE INTERIOR
ELEVATIONS FOR EXACT
QUANITITY OF DRAWERS,
DOORS, AND SHELVES
REFRIGERATOR
MELAMINE ON 1/2" SUBSTRATE BACK
CABINET SIDES AND BOTTOM:
MELAMINE ON 3/4" SUBSTRATE
BLACK MELAMINE ON 3/4"
SUBSTRATE ADJ. SHELF
BRACKET HOLES AT 2" O.C.
VERTICALLY
CABINET PULL AS SCHEDULED, SOFT
CLOSE
DOOR FRONTS; PLASTIC
LAMINET STILE AND RAIL 2 1/2",
DRAWER SIZES PER ELEVATIONS
Johnston Architects, PLLC
100 NE Northlake Way,
Suite 200
Seattle, WA 98105
t 206.523.6150
f 206.523.9382
SHEET TITLE
SHEET NO.
03.07.22
DRAWING ISSUE
PERMIT SET
DATE DESCRIPTION
10/17/2022
07.18.22 BID SET
10.17.22 BID SET RE-ISSUE
10/17/2022 12:58:05 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057CASEWORK
DETAILS
A900
SCALE: 1 1/2" = 1'-0"
TALL CABINET1
SCALE: 1 1/2" = 1'-0"
BASE CABINET - DRAWERS2SCALE: 1 1/2" = 1'-0"
BASE CABINET - TRASH & RECYCLE3
SCALE: 1 1/2" = 1'-0"
OPEN SHELVING4 SCALE: 1 1/2" = 1'-0"
CLOSED UPPERS5 SCALE: 1 1/2" = 1'-0"
CABINET AT REF6