Loading...
HomeMy WebLinkAboutBid DrawingsPH: CITY OF RENTON OWNER: 616 W PERIMETER RD, UNIT A RENTON, WA 98057 (206) 200-6811 CONTACT: WILLIAM ADAMS wadams@rentonwa.gov PH: JOHNSTON ARCHITECTS LLC ARCHITECT: 100 NE NORTHLAKE WAY, SUITE 200 SEATTLE WA 98105 (206) 523-6150 CONTACT: GENEVIEVE THERIAULT GTHERIAULT@JOHNSTONARCHITECTS.COM PROJECT TEAM PROJECT INFORMATION OWNER CITY OF RENTON PARCEL # 0723059007 LEGAL DESCRIPTION POR SECS 7 & 18-23-5 & POR TOBINS D C INCL POR PLATTED & VAC STS LY WLY OF COMM W W # 2 N OF N LN DIXIE AVE & ELY OF STATE HWAY # 5 & ELY & SLY OF FOLG LN BEG ON ELY MGN SD HWAY AT PT 5 FT S OF N LN OF LOT 8 BLK 18 BRYN MAWR TH E 89.23 FT TH N 05-16-51 E 438.90 FT TH N 40-09-47 E 188.55 FT TH N 60 FT TH N 29-00-40 W 197.07 FT TH S 88-27-28 E 90.83 FT TH N 01-32-32 W 40 FT TH S 88-27-28 E 234.53 FT TH S 35-00-00 E 142.41 FT TH E 403.70 FT LESS LOTS 19 TO 22 INCL BLK 4 RENTON REAL ESTATE COS 1ST ADD LESS PORTION FOR LANE HANGAR CONDOMINIUM -TGW POR OF RAINIER AVE N PER RENTON VAC ORD #5780 PROJECT DESCRIPTION RENOVATION OF EXISTING 2,390 SF OFFICE BUILDING INCLUDING NEW NON LOAD-BEARING INTERIOR PARTITIONS, NEW FINISHES, NEW CASEWORK, REMODELED RESTROOMS, AND NEW ADA RAMPS W P E R I M E T E R R D AIRPORT WAYRAINIER AVE NRAINIER AVE SRENTON AVE SPRIMARY ENTRY JURISDICTION CITY OF RENTON ZONING CODE RENTON MUNICIPAL CODE BUILDING CODE 2018 INTERNATIONAL BUILDING CODE OTHER RELEVANT CODES 2018 WASHINGTON STATE ENERGY CODE 2018 UNIVERSAL PLUMBING CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL FIRE CODE WASHINGTON ADMINISTRATIVE CODE (WAC) ADA STANDARDS FOR ACCESSIBLE DESIGN, 2010 AMMENDMENTS AS ADOPTED BY THE CITY OF RENTON APPLICABLE CODES NEW ENCLOSED HEATED SPACE NO CHANGE MECHANICAL SYSTEM NO CHANGE COMPLIANCE PATH PRESCRIPTIVE, WASHINGTON STATE ENERGY CODE CH 51-11C WAC, C503.3.2.1 GLAZING U-VALUE (METAL FRAMING FIXED): 0.38 GLAZING U-VALUE (METAL FRAMING OPERABLE): 0.40 DOOR U-VALUE (METAL FRAMING) 0.60 ENERGY CODE NOTES ADDRESS 243 W PERIMETER RD, RENTON, WA PARCEL NUMBER 0723059007 OCCUPANCY CLASSIFICATION GROUP B - OFFICE EXISTING BUILDING CONSTRUCTION TYPE V-B LOT SIZE 6,640,728 SF ZONING IM (MEDIUM INDUSTRIAL) YEAR BUILT 1973 SPRINKLERS NO NUMBER OF STORIES 1 STORY EXISTING BUILDING SQUARE FOOTAGE 2,420 SF AREA OF WORK 2,420 SF SITE & BUILDING DATA 6,223'-7"AIRPORT WAYRAINIER AVE NE PERIMETER RDW PERIMETER RDRENTO N AVE SENLARGED SITE PLAN 1 ,2 6 1 '-5 " 2,002'-9" 1 4 2 '-0 "104'-0"114'-0"47'-3"57'-7"18'-0"17'-9"21'-10"SIDEWALK PROPERTY LINE PARKING LOT W PERIMETER RD AIRPORT WAYRAINIER AVE SJohnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:58:07 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057PROJECT INFORMATION G001 RENTON MUNICIPAL AIRPORT OFFICE REMODEL 243 W PERIMETER RD RENTON, WA 98057 PROJECT INFORMATION G001 PROJECT INFORMATION G002 GENERAL NOTES & CODE SUMMARY G003 OCCUPANCY / EGRESS PLAN ARCHITECTURAL A200 DEMO & NEW FLOOR PLANS A201 DEMO & NEW RCP A202 FINISH PLAN A500 EXTERIOR RAMPS A700 INTERIOR ELEVATIONS - CONFERENCE & OFFICE A701 INTERIOR ELEVATIONS - RECEPTION A702 INTERIOR ELEVATIONS - RESTROOMS A710 ACCESSIBILITY PLANS & DETAILS A800 DOOR AND WINDOW SCHEDULE & DETAILS A810 INTERIOR WALL ASSEMBLIES & DETAILS A900 CASEWORK DETAILS LOCATION PLAN DRAWING INDEX VICINITY MAP SITE 405 AIRPORT WAYRAINIER AVE NRAINIER AVE SR E N T O N A V E S LOGAN AVE NPARK AVE NN SOUTHPORT DRSITE PLAN -ENLARGED SITE PLAN 1" = 40'1" = 1100' GENERAL NOTES THE CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL APPLICABLE SAFETY CODES. THE CONTRACTOR SHALL INDEMNIFY AND HOLD JOHNSTON ARCHITECTS HARMLESS FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY NEGLIGENCE OF CONTRACTOR, HIS AGENT, EMPLOYEES, OR SUBCONTRACTORS. EACH CONTRACTOR/SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND IS RESPONSIBLE FOR THE REPAIR OF SAID DAMAGE AT THEIR OWN EXPENSE. THE CONTRACTOR SHALL REPORT ERRORS AND OMISSIONS TO THE ARCHITECT IMMEDIATELY IN WRITING. DO NOT VARY OR MODIFY THE WORK SHOWN EXCEPT UPON WRITTEN INSTRUCTIONS OF THE ARCHITECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WALL BLOCKING AS REQUIRED FOR ALL WALL AND CEILING MOUNTED ITEMS. COORDINATE WITH THE ARCHITECT AND/OR OWNER LOCATION OF ALL MOUNTED ITEMS WHICH ARE N.I.C. ALL CONSTRUCTION SHALL BE STABILIZED AGAINST LATERAL MOVEMENT IN ACCORDANCE WITH REQUIREMENTS OF THE LATEST ADOPTED EDITION OF THE I.B.C. IN THE LOCAL JURISDICTION AND IN STRICT ACCORDANCE WITH THE STRUCTURAL DETAILS OF THIS SET OF DRAWINGS. ALL WORK SHALL BE INSTALLED TRUE, PLUMB, SQUARE, LEVEL AND IN PROPER ALIGNMENT. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. MECHANICAL, ELECTRICAL, VERTICAL TRANSPORTATION, & SPRINKLER WORK CONDUCTED UNDER SEPARATE PERMIT & NOT PART OF THIS CONTRACT. INSTALL ALL FIXTURES, EQUIPMENT, AND MATERIALS PER MANUFACTURER'S SPECIFICATION. EACH CONTRACTOR/SUBCONRACTOR SHALL BE RESPONSIBLE FOR LEAVING ALL AREAS CLEAN AND READY FOR THEIR INTENDED USE. CONTRACTOR SHALL GUARANTEE ALL WORK AGAINST FAULT OF ANY MATERIAL OR WORKMANSHIP FOR PERIOD OF ONE YEAR AFTER COMPLETION AND ACCEPTANCE. FAULTY WORK SHALL BE REPLACED OR REPAIRED AS REQUIRED AT CONTRACTOR'S EXPENSE. 1.A 1.B 1.C 1.D 1.E 1.F 1.G 1.H 1.I 1.J 1.K 1.L 1.M 1. GENERAL: THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT. AUTHORIZED REPRODUCTION MUST BEAR THE NAME OF THE FIRM. IN CASE OF DISCREPANCY OR AMBIGUITY, CONTACT THE ARCHITECT FOR CLARIFICATION PRIOR TO PROCEEDING WITH ANY WORK. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION, WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED ONLY SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR THE ARCHITECT'S APPROVAL PRIOR TO MANUFACTURE OF ANY CABINET WORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATED WORK. DRAWINGS INCLUDE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE COMPLETE OR REPRESENTATIVE OF CONDITIONS OR MATERIALS SPECIFICALLY USED ON THE PROJECT. THE ARCHITECT WILL DEFINE THE INTENT OF ANY DEFINITION OR TERM IN QUESTION. 3.A 3.B 3.C 3.D 3.E 3. DRAWINGS: ALL WORK SHALL BE IN COMPLIANCE WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES INCLUDING BUT NOT LIMITED TO THE 2018 I.B.C., THE WASHINGTON STATE ENERGY CODE AND GOVERNING MECHANICAL CODE WITHIN THE JURISDICTION OF THE PROJECT. IN CASE OF CONFLICT WHERE METHODS OR STANDARDS OF INSTALLATION OR MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE ORDINANCES SHALL GOVERN. NOTIFY THE ARCHITECT OF ANY CONFLICT. IMPORTANT: IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND EACH AND EVERY SUBTRADE TO ENSURE EVERY ASPECT OF THIS WORK IS IN COMPLIANCE WITH THE PREVAILING CODES. 2.A 2.B 2. CODES: DO NOT SCALE THESE DRAWINGS. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR CONDITIONS ADVERSELY EFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE ITEM OF WORK EFFECTED. DIMENSIONS ON THE PLANS ARE TO FACE OF STRUCTURE, UNLESS OTHERWISE NOTED. 5.A 5.B 5. DIMENSIONS: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION AND COORDINATION OF THE WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH THE DRAWINGS AND SPECIFICATIONS. 6.A 6. COORDINATION: FIRE PROTECTION CONTRACTORS SHALL PROVIDE FIRE PROTECTION DRAWINGS REQUIRED BY GOVERNING AUTHORITY. DRAWINGS SHOULD BE SUBMITTED TO THE ARCHITECT FOR REVIEW. PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RATED ELEMENTS REQUIRED BY THE FIRE OFFICIAL. EXISTING FIRE ALARM SYSTEMS SHALL REMAIN INTACT AND OPERABLE AT ALL TIMES. 7.A 7.B 7.C 7. FIRE PROTECTION: THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING COMPLIANCE WITH ALL CODES AND OBTAINING ALL NECESSARY PERMITS. ALL DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BY THE ARCHITECT. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE LOCATION OF EACH CORE DRILL WITH THE EXISTING STRUCTURE, PIPING, CONDUIT, ETC. AND SHALL NOTIFY THE ARCHITECT OF ANY CONFLICTS OR OBSTRUCTIONS. ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND CONTRACT DOCUMENTS SHOULD BE CALLED TO THE ATTENTION OF THE ARCHITECT. ALL NEW ELECTRICAL/TELEPHONE OUTLETS ARE TO BE MOUNTED VERTICALLY AT 18" AFF UNLESS NOTED. ALL NEW ELECTRICAL/TELEPHONE OUTLETS OVER COUNTERS ARE TO BE MOUNTED VERTICALLY AT 44" AFF UNLESS NOTED. ALL WALL MOUNTED RECEPTACLES LOCATED IN CASEWORK ARE TO BE MOUNTED HORIZONTALLY UNLESS OTHERWISE NOTED. SPECIAL HEIGHTS ARE NOTED ADJACENT TO THE OUTLET. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING COMPLIANCE WITH ALL ADA REQUIREMENTS FOR HEIGHTS OF FIXTURES AND DEVICES (I.E. SWITCHES, OUTLETS ETC.) 8.A 8.B 8.C 8.D 8.E 8.F 8.G 8. ELECTRICAL NOTES: ALL FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE THE ARCHITECT'S APPROVAL PRIOR TO INSTALLATION. PROVIDE ARCHITECT 3 SAMPLES PER FINISH FOR ARCHITECTS REVIEW BEFORE ORDERING. 10.A 10. FINISH NOTES: # NUMBER ∠ANGLE ACST ACOUSTICAL ADA AMERICANS WITH DISABILITIES ACT ADDL ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISH FLOOR AP ACCESS PANEL APPROX APPROXIMATE ARCH ARCHITECT (URAL) ASTM AMERICAN SOCIETY FO TESTING MATERIALS AWI ARCHITECTURAL WOODWORKING INSTITUTE BD BOARD BLDG BUILDING BLKG BLOCKING BM BEAM BO BOTTOM OF BOF BOTTOM OF FOOTING CAB CABINET CB CATCH BASIN C.C. CENTER TO CENTER CFM CUBIC FEET PER MINUTE CFOI CONTRACTOR FURNISHED; OWNER INSTALLED CH CHANNEL CI CAST IRON CIP CAST-IN-PLACE (CONCRETE) CL CENTERLINE CLG CEILING CLR CLEAR CO CLEAN OUT COL COLUMN CONC CONCRETE CONT CONTINUOUS COORD COORDINATE CPT CARPET (ED) CSMT CASEMENT CT CERAMIC TILE D DEEP ° or DEG DEGREE DEMO "DEMOLISH, DEMOLITION" DEPT DEPARTMENT DET DETAIL ⌀or DIA DIAMETER dB DECIBEL DIM DIMENSION DN DOWN DR DOOR DS DOWNSPOUT DWG DRAWING DWR DRAWER (E) EXISTING E EAST EA EACH EL ELEVATION ELEC ELECTRIC (AL) ENCL ENCLOSE (URE) EQ EQUAL EQUIP EQUIPMENT ESMT EASEMENT EST ESTIMATE (D) EW EACH WAY EXH EXHAUST EXP EXPANSION EXT EXTERIOR FD FLOOR DRAIN FDN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FIN FINISH (ED) FL FLASHING FLR FLOOR FM FACTORY MANUAL FOC FACE OF CONCRETE FOF FACE OF FINISH FOIC FURNISHED BY OWNER INSTALLED BY CONTRACTOR FOIO FURNISHED BY OWNER INSTALLED BY OWNER FOS FACE OF STUDS FRMG FRAMING FRT FIRE RETARDANT TREATED FT "FOOT, FEET" FTG FOOTING FURN FURNITURE G NATURAL GAS GA GAGE GAL GALLON GALV "GALVANIZED, GALVANIC" GAR GARAGE GB GRAB BAR GC GENERAL CONTRACTOR GEN GENERAL GL GLASS GLU LAM GLUED LAMINATED WOOD GOVT GOVERNMENT GSM GALVANIZED SHEET METAL GWB GYPSUM WALL BOARD H HEIGHT HDR HEADER HDW HARDWARE HDWD HARDWOOD HLDN HOLDDOWN HM HOLLOW METAL HO HOLD OPEN HORIZ HORIZONTAL HR HOUR HVAC "HEATING, VENTILATION, AND AIR CONDITIONING" HWH HOT WATER HEATER ID INSIDE DIAMETER IIC IMPACT ISOLATION CLASS IN INCH (S) INCL INCLUDING (ED) INFO INFORMATION INSUL INSULATION INT INTERIOR JAN JANITOR JST JOIST (S) KIT KITCHEN KW KILOWATT L LENGTH LAM LAMINATE(D), LIQUID APPLIED MEMBRANE LAV LAVATORY ABBREVIATIONS LB (S) POUND (S) LF LINEAL FOOT/FEET LH LEFT HAND LHR LEFT HAND REVERSE LNDSCP LANDSCAPE LOC LOCATION LTG LIGHTING LVL LAMINATED VENEER LUMBER MACH RM MACHINE ROOM MAG MAGNET(IC) MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MEMB MEMBRANE MEP MECHANICAL, ELECTRICAL, PLUMBING MFD MANUFACTURED MFR MANUFACTURER MIN "MINIMUM, MINUTE" MIRR MIRROR MISC MISCELLANEOUS MTL METAL MULL MULLION MULT MULTIPLE (N) NEW NA NOT APPLICABLE NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL N NORTH NTS NOT TO SCALE O/ OVER OA OVERALL OC ON CENTER OD "OUTSIDE DIAMETER, DIMENSION" OFF OFFICE OH OVERHANG OPP HAND OPPOSITE HAND OPNG OPENING OVHD OVERHEAD PBD PARTICLE BOARD PED PEDESTAL PERF PERFORATED PERIM PERIMETER PERM PERMANENT PERP PERPENDICULAR PH PHASE PL PROPERTY LINE PLAM PLASTIC LAMINATE PLWD PLYWOOD PR PAIR PRCST PRECAST PREFAB PREFABRICATED PRELIM PRELIMINARY PRKG PARKING PROJ PROJECT PROP PROPERTY PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PSL PARALLEL STRAND LUMBER PTD PAINTED PTN PARTITION PVA POLYVINYL ACRYLIC PVC POLYVINYL CHLORIDE PVG PAVING QTY QUANTITY R "RADIUS, RISER" RCP REFLECTED CEILING PLAN RD "ROOF DRAIN, ROAD" REC RECESSED REF "REFER (ENCE), REFRIGERATOR" REINF "REINFORCE (D), (ING)" REQD REQUIRED RESIL RESILIENT REV "REVISION (S), REVISED" RH "ROOF HATCH, RIGHT HAND" RHR RIGHT HAND REVERSE RM ROOM RO ROUGH OPENING ROW RIGHT OF WAY RT RIGHT RWL RAINWATER LEADER S SOUTH SCHED SCHEDULE SD STORM DRAIN SF SQUARE FOOT (FEET) SHT SHEET SIM SIMILAR SPEC SPECIFICATION SPKLR SPRINKLER SQ SQUARE SQ IN SQUARE INCH SST STAINLESS STEEL ST "STAIRS, STREET" STC SOUND TRANSMISSION CLASS STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURE (AL) SUSP SUSPEND(ED) SV SHEET VINYL T TREAD TBD TO BE DETERMINED TEL TELEPHONE TEMP TEMPORARY TFF TOP OF FINISH FLOOR THK THICK (NESS) THRU THROUGH TOB TOP OF BEAM TOC TOP OF CURB TOW TOP OF WALL TYP TYPICAL UBC UNIFORM BUILDING CODE UL UNDERWRITERS LABORATORIES UNO UNLESS NOTED OTHERWISE UTIL UTILITY VCT VINYL COMPOSITION TILE VERT VERTICAL VIF VERIFY IN FIELD V VOLT W "WEST, WIDTH, WASHER" W/ WITH W/O WITHOUT WD "WOOD, WOOD DOOR" WDW WINDOW WRB WEATHER RESISTIVE BARRIER E 4 X X 144.25' NEW COLUMN GRIDS EXIST/ADJ BLDG COLUMN GRIDS NORTH ARROW BUILDING ELEVATION DRAWING NUMBER SHEET NUMBER INTERIOR ELEVATION DRAWING NUMBER SHEET NUMBER BUILDING SECTION DRAWING NUMBER SHEET NUMBER WALL SECTION DRAWING NUMBER SHEET NUMBER DETAIL DRAWING NUMBER SHEET NUMBER SPOT ELEVATION MATCHLINE DRAWING SHT. SHOWING ADJ. CONDITION DATUM / CONTROL POINT CONTOURS REVISED CONTOURS EXISTING CONTOURS NEW WALL EXISTING WALL WALL TO BE REMOVED FINISH TAG CEILING HEIGHT TAG ROOM TAG DOOR TAG WINDOW TAG ASSEMBLY TAG (WALL, FLOOR, CLG, ROOF) REVISION TAG / REVISION CLOUD EXIT SIGN FIRE EXTINGUISHER SMOKE DETECTOR 8'-0" P-1 A310 1A 1B 1C 1D A1 A201 A1 A210 A1 A501 A01 0101A 1t 1 MATCH LINE SEE XX/X-XXX FECA1 A210 ROOM 101 SYMBOL LEGEND NJohnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:58:07 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057GENERAL NOTES & CODE SUMMARY G002 284 SF OFFICE 390 SF RECEPTION 229 SF OFFICE 347 SF CONFERENCE 200 SF OFFICE 235 SF OFFICE REQUIRED SEPARATION73'-3" / 2 = 36' 7 1/2"Building Common Area Office Area ASSEMBLY AREA . 40'-7"OCCUPANCY: 23 OCCUPANCY: 1 OCCUPANCY: 2 OCCUPANCY: 2 OCCUPANCY: 2 OCCUPANCY: 26 41" 60" OCCUPANCY LOAD SERVED BY DOOR & HALLWAY: 26 IBC TABLE 1006.2.1 MAX 75' COMMON PATH OF TRAVEL DISTANCE 52' TRAVEL DISTANCE PROVIDED IBC TABLE 1017.2 MAX 200' TRAVEL DISTANCE 77'-9" TRAVEL DISTANCE PROVIDED EXIT EXIT OFFICE AREA . OCCUPANCY LEGEND 5'-6"COMMON PATH OF TRAVEL PATH OF EGRESS DECISION POINT EXIT SIGN EGRESS PLAN LEGEND Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:58:09 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057OCCUPANCY / EGRESS PLAN G003 OCCUPANCY LOAD NAME OCCUPANCY AREA OCCUPANT LOAD FACTOR NUMBER OF OCCUPANTS CALCULATED NUMBER OF OCCUPANTS RECEPTION A3 390 SF 15 26.02 26 CONFERENCE A3 347 SF 15 23.14 23 OFFICE B 284 SF 150 1.90 2 OFFICE B 229 SF 150 1.52 2 OFFICE B 200 SF 150 1.33 1 OFFICE B 235 SF 150 1.57 2 6 1685 SF 55.48 56 SCALE: 3/16" = 1'-0" OCCUPANCY / EGRESS PLAN1 N 02'12'16' 4'8' AREA TOTAL FLOOR AREA 2,420 SF PROJECT AREA OF WORK 2,420 SF OCCUPANCY LOAD CALCULATIONS SEE OCCUPANCY SCHEDULE EXIT REQUIREMENTS NUMBER OF EXITS REQUIRED 2 NUMBER OF EXITS PROVIDED 2 EGRESS WIDTH (INCHES) REQUIRED 0.2 X 56 = 11.2"; 44" MIN EGRESS WIDTH (INCHES) PROVIDED 60" EGRESS WIDTH (INCHES) REQUIRED WHERE OCCUPANCY SERVED < 50 36" MIN EGRESS WIDTH (INCHES) PROVIDED WHERE OCCUPANCY SERVED < 50 41" MIN EXIT SEPARATION NOT SPRINKLERED REQUIRED EXIT SEPARATION > 1/2 DIAGONAL SEPARATION PROVIDED SEE PLAN COMMON PAHTH OF TRAVEL NOT SPRINKLERED MAXIMUM COMMON PATH OF TRAVEL 75' IBC TABLE 1006.2.1 MAXIMUM EXIT ACCESS TRAVEL DISTANCE 200' IBC TABLE 1017.2 EGRESS SUMMARY 33333DEMO EXISTING FLOORING THROUGHOUT TYP DEMO (E) PARTITIONS & (E) DOOR, PATCH AND REPAIR AS NEEDED DEMO (E) BAR, PROTECT (E) PLUMBING IN WALL FOR REUSE DEMO (E) PARTITIONS & (E) DOOR, PATCH AND REPAIR AS NEEDED DEMO (E) RESTROOM FIXTURES AND FLOORING. PROTECT (E) PLUMBING IN WALL FOR REUSE. PATCH AND REPAIR WALL AS NEEDED. DEMO (E) RESTROOM FIXTURES AND FLOORING. PROTECT (E) PLUMBING IN WALL FOR REUSE. PATCH AND REPAIR WALL AS NEEDED. DEMO EXISTING FLOORING THROUGHOUT TYP DEMO EXISTING FLOORING THROUGHOUT TYP DEMO EXISTING FLOORING THROUGHOUT TYP DEMO EXISTING FLOORING THROUGHOUT TYP DEMO EXISTING FLOORING THROUGHOUT TYP DEMO EXISTING DECKING AND RAILING, PREP FOR NEW DEMO DOORS PREP FOR NEW, TYP REVERSE SWING OF EXISTING DOOR PER NEW PLAN -KEEP EXISTING DOOR & FRAME REMOVE BROKEN WINDOW REMOVE EXISTING SLIDER DOOR REMOVE BROKEN WINDOW REMOVE BROKEN WINDOW 2'-1"SAW CUT SLAB FOR NEW FLOOR OUTLET OFFICE 3 MECH 4 RECEPTION & LOUNGE 1 OFFICE 6 CONFERENCE & BREAKROOM 7 OFFICE 9 RESTROOM 10 OFFICE 11 NEW WOOD DECKING AND RAILING TO REPLACE EXISTING. RAILING TO MATCH EXISTING REPLACE BROKEN WINDOW WITH BUILDING TYP WINDOW COUNTER 34"AFF OUTDOOR LOUNGE 2 NIC IT ALCOVE RESTROOM 5 (E) AC 6'-1"11 10 3c COPY 8 NEW ACCESSIBLE RAMP. SLOPE 1:12 NEW ACCESSIBLE RAMP. SLOPE 1:123'-6"5'-0"10'-0"5'-1"CLR 5'-2"13'-0"5'-2"3'-6"COUNTER 34"AFF 5 (e) (e) 1a 1b 1c 9 SLIDING SCREENS 29" HIGH RECEPTION COUNTER, PROVIDE POWER AND DATA IN DESK A3a A3a A3a A3a A3a ________ A500 2 ________ A500 1 ________ A702 3 ________ A702 2 ________ A701 6 EXISTING OUTLETS SHOWN HALFTONE, VIF & NOTIFY ARCH WITH DISCREPANCIES RELOCATE SWITCHES GFIC GFICREF 44" AFF CRCRCRPROVIDE NEW COVER PLATES FOR ALL ELECTRICAL FIXTURES TO REMAIN, TYP THROUGHOUT PROVIDE NEW WINDOW WHERE EXISTING SLIDER DOOR WAS REMOVED, VERIFY SIZE IN FIELD VERFIY FLOOR LOCATION WITH FURN VENDOR PAINT EXISTING EXTERIOR METAL SIDING. ASSUME TWO COLORS, 1 MAIN COLOR AND 1 ACCENT TRIM COLOR. AVCORDINATE IT POWER REQUIREMENTS WITH OWNER & IT PROVIDE BACKING FOR WALL MOUNTED IT RACKS AS NEEDED 3a5'-6"5'-8"2'-4"PRINT8"CLEAR 5'-0"4'-1" 6 UPGRADE TO KEY PAD LOCK 7 3b IN DESK POWER DATA SEE (A701) REPLACE BROKEN WINDOW WITH BUILDING TYP WINDOW REPLACE BROKEN WINDOW WITH BUILDING TYP WINDOW UP UPDECK STRUCTURE TO REMAIN. GC TO VERIFY INTEGRITY IN FIELD. FEC FEC FEC FEC PRINTER, CONFIRM POWER DATA REQUIREMENTS PER PRINTER NEW WALL EXISTING WALL WALL TO BE REMOVED WALL LEGEND POWER LEGEND 1. ASBESTOS & HAZARDOUS MATERIALS: FEDERAL, STATE & LOCAL REGULATIONS REQUIRE THAT ALL ASBESTOS & OTHER HAZARDOUS MATERIALS IN A BUILDING BE REMOVED PRIOR TO STARTING THE DEMOLITION WORK. CONTRACTOR TO OBTAIN REQUIRED CERTIFICATION THAT THERE ARE NO HAZARDOUS MATERIALS PRESENT IN THE STRUCTURE. 2. U.O.N. ALL DEBRIS RESULTING FROM DEMOLITION WORK SHALL BECOME THE PROPERTY OF THE CONTRACTOR & SHALL BE REMOVED & DISPOSED OF IN A LEGAL MANNER OFF OF THE PROJECT PROPERTY. 3. SEE MEP (UNDER SEPARATE PERMIT), FIRE PROTECTION (UNDER SEPARATE PERMIT), ELECTRICAL (UNDER SEPARATE PERMIT) & COMMUNICATION (UNDER SEPARATE PERMIT) DOCUMENTS FOR DEMOLITION RELATED TO THOSE TRADES. 4. MEP, FIRE PROTECTION, ELECTRICAL, AND COMMUNICATION PERMITS ARE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL COORDINATE DEMOLITION NEEDS OF THOSE TRADES. 5. THE CONTRACTOR SHALL TAKE PRECAUTIONS TO ADEQUATELY SECURE THE PREMISES & /OR STORED MATERIALS FROM TRESPASSING, THEFT & VANDALISM. 6. PROTECT EXISTING WINDOWS AT PERIMETER DURING CONSTRUCTION. CLEAN WINDOWS PRIOR TO OCCUPANCY. 7. DEMO ALL FLOORING FINISHES IN AREAS OF WORK U.O.N.; PATCH & PREPARE EXISTING FLOORS IN AREAS TO RECEIVE NEW FLOORING TO PROVIDE FOR CONTINUOUS "LEVEL" SURFACE FOR NEW FLOORING. 8. DO NOT REMOVE ANY BEARING WALLS, COLUMNS OR OTHER STRUCTURAL MEMBERS NOT DESIGNATED IN THE DOCUMENTS. NOTIFY ARCHITECT IMMEDIATELY IF AREAS OF DEMO UNCOVER ANY EXISTING STRUCTURAL COMPONENTS NOT PREVIOUSLY IDENTIFIED. 9. REMOVE ALL WALLCOVERING ON WALLS TO REMAIN 10. PRIOR TO REMOVAL OF ANY STRUCTURAL COMPONENTS, THE CONTRACTOR SHALL PROVIDE SHORING AS REQUIRED TO TEMPORARILY SUPPORT ALL LOADS UNTIL NEW FRAMING IS INSTALLED AS DOCUMENTED AND SPECIFIED. IF THE CONTRACTOR FINDS THE EXISTING CONDITIONS TO BE OTHER THAN DOCUMENTED OR IN CONFLICT WITH THE DRAWINGS, NOTIFY THE ARCHITECT IMMEDIATELY FOR RESOLUTION. PROCEEDING WITHOUT NOTIFICATION INDICATES FULL ACCEPTANCE OF CONDITIONS AND RESPONSIBILITY IF WORK IS NOT IN CONFORMANCE WITH CONTRACT DOCUMENTS. 11. ALL EXISTING ELECTRICAL OUTLETS, SWITCHES AND FACE PLATES TO REMAIN SHALL BE PROTECTED DURING DEMOLITION AND/OR SAVED FOR FUTURE USE AS INDICATED IN THE DOCUMENTS. CONSULT POWER PLANS FOR SPECIFIC ELECTRICAL WORK. DEMO NOTES 1. EXISTING SHELL & CORE CONSTRUCTION SHOWN w/ WHITE POCHE 2. REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL DIMENSIONS DESCRIBING PARTIAL HEIGHT WALLS, CASEWORK LAYOUT, SPECIALTY OUTLET LOCATIONS, ETC. 3. REFER TO REFLECTED CEILING PLANS FOR SOFFITS, CEILING HEIGHTS & PLENUM BARRIER LOCATIONS. 4. REFER TO SHEET G002 FOR ADDITIONAL NOTES, LEGENDS, SYMBOLS, ABBREVIATIONS, & SCHEDULES. 5. PATCH/REPAIR, PRIME & PAINT ALL EXISTING GWB WALLS TO REMAIN. 6. ALL PARTITIONS ARE DIMENSIONED FROM FINISH FACE OF GYPSUM BOARD TO FINISH FACE OF GYPSUM BOARD UNLESS OTHERWISE NOTED. ALL DIMENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED & SHALL ALLOW FOR THICKNESS OF ALL WALL FINISHES, UON & SHALL NOT VARY MORE THAN ± 1/8" WITHOUT WRITTEN INSTRUCTION FROM ARCHITECT. 7. PARTITIONS THAT ARE NOT DIMENSIONED ARE TO BE LOCATED FLUSH & SQUARE WITH THE EXISTING PARTITION OR CENTERLINE OF WINDOW MULLION AS SHOWN. 8. WALLS THAT APPEAR TO ALIGN DO ALIGN. WALLS THAT APPEAR CENTERED ON COLUMNS OR MULLIONS ARE CENTERED ON COLUMNS OR MULLIONS. 9. "ALIGN" MEANS TO ACCURATELY LOCATE THE FINISHED FACES IN THE SAME PLANE. 10. DIMENSIONS MARKED ± MEAN A TOLERANCE NOT GREATER NOR SMALLER THAN 2 INCHES FROM INDICATED DIMENSION, U.N.O. VERIFY FIELD DIMENSIONS EXCEEDING TOLERANCE WITH THE ARCHITECT. SECURE ARCHITECT'S APPROVAL. 11. NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES OR CONFLICTS IN THE LOCATION(S) OF NEW CONSTRUCTION. UPON COMPLETION OF PARTITION LAYOUT, NOTIFY ARCHITECT. ALLOW TIME IN THE SCHEDULE FOR VERIFICATION OF THE LAYOUT BY THE ARCHITECT PRIOR TO PARTITION INSTALLATION. 12. ALL WORK SHALL BE ERECTED & INSTALLED PLUMB, LEVEL, SQUARE & TRUE. 13. DIMENSIONS LOCATING DOORS ARE TO FINISHED OPENING, UON. 14. COPY/PRINT, INTERIOR PLANTS, AND FURNITURE EQUIPMENT TO BE PROVIDED BY OWNER. 15. ALL NEW WALLS TO BE LEVEL 4 FINISH, LEVEL 5 AT WALLCOVERING. NEW PLAN NOTES 1. POWER AND DATA REQUIREMENTS TO BE VERIFIED WITH CONTRACTOR'S ELECTRICAL DESIGN-BUILD ENGINEER. 2. ALL POWER/DATA OUTLETS TO BE LOCATED @ +18" A.F.F., U.O.N. 3. ALL POWER/DATA OUTLETS ABOVE COUNTERS TO BE LOCATED @ +44" A.F.F, U.O.N. 4. PROVIDE ELECTRICAL POWER FOR ALL NEW APPLIANCES. 5. SERVE NO MORE THAN 6 GENERAL PURPOSE OUTLETS FROM A SINGLE 20A, 120V CIRCUIT. 6. IN-FEED FOR WORKSTATION POWER -TYPICAL TO BE 20 AMP CIRCUITS NON- DIRECTIONAL 8-WIRE CONFIG.: 4 HOTS, 2NEUTRAL, 2 GROUNDS. CONTRACTOR TO CONNECT ELECTRICAL TO WORKSTATION. PANEL-TO-PANEL CONNECTION TO BY BY FURNITURE VENDOR. 7. CONFIRM LOCATIONS OF ALL FURNITURE POWER FEEDS WITH FURNITURE VENDOR PRIOR TO ROUGH-IN. 8. VERIFY CONFIGURATION OF FLUSH POKE-THRU DEVICES WITH TENANT AV CONSULTANT AND ARCHITECT PRIOR TO INSTALLATION. 9. ALL DEVICES AND COVER PLATES TO BE WHITE U.O.N. SEE FINISH SCHEDULE FOR COVERPLATE INFORMATION POWER PLAN NOTES 10. CONTRACTOR TO PULL OWNER-PROVIDED CAT-6 CABLE TO LOCATIONS SHOWN ON PLAN; OWNER WILL TERMINATE AT IT CABINET. 11. SPEAKERS AND ASSOCIATED CABLING BY TENANT'S SELECTED VENDOR. GC TO COORDINATE LOCATIONS AND WORK WITH VENDOR. 12. IT ALCOVE REQUIREMENTS: CONFIRM FINAL LAYOUT / CONFIGURATION AND LOCATION OF OUTLETS WITH OWNER. 13. COORDINATE LOCATION OF ELECTRICAL OUTLETS FOR WALL MOUNTED MONITORS WITH OWNER'S AV CONSULTANT 14. CONTRACTOR TO PULL OWNER-PROVIDED SECURITY CAMERA WIRING. OWNER WILL COORDINATE SECURITY CAMERA INSTALL WITH THEIR VENDOR. 15. CONTRACTOR TO PROVIDE POWER AT CARD-READER LOCATIONS NOTED. OWNER TO SUPPLY & INSTALL CARD- READERS. FLUSH FLOOR OUTLET W/ POWER AND TEL/DATA CONNECTION - ALL LOCATIONS TO BE RJ45 CAT6, 2 PORT UONGFICEXISTING DUPLEX, CONTRACTOR TO VIF DUPLEX GFCI DUPLEX DATA - ALL LOCATIONS TO BE RJ45 CAT6,2 PORT UON DATA - ALL LOCATIONS TO BE RJ45 CAT6,2 PORT UON CRCARD READERAV Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:57:54 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057DEMO & NEW FLOOR PLANS A200 SCALE: 3/16" = 1'-0" DEMO PLAN2 N SCALE: 3/16" = 1'-0" NEW FLOOR PLAN1 02'12'16'4'8' N 02'12'16' 4'8' 333333L-1 L-1EM L-1L-1 L-1 L-1 L-1 L-1 E-4 E-4 E-4E-4REMOVE EXISTING SWITCHES LOCATED IN CASEWORK WALL. RELOCATE PER PLAN L-1EM L-1L-1 L-1 REPLACE E-3 LIGHT FIXTURES WITH NEW L-1 IN EXISTING LOCATIONS, TYP D-1 PROTECT E-4 SCONCE DURING COSTRUCTION,TYP PAINT ALL EXISTING GRILLS AND MECHANICAL TO REMAIN TO MATCH CEILING, TYP THROUGHOUT MATCH SPACING OF EXSITING FIXTURES+/- 6'-8"L-1 L-1 2'-6"2'-6"4'-0" L-1EM 4'-0" L-1 EQEQEQ EQ L-1W L-1 L-1 ALIGN W/ EXISTING 3'-3" L-1 L-1EMALIGN W/ EXISTINGL-1EML-1 4'-5"4'-5" L-1L-1 3'-3"3'-3"L-1WEQ EQSEE ELEVATIONS FOR WALL SCONCE LOCATIONS L-1W2'-5" 2'-5" SEE ELEVATIONS FOR WALL SCONCE LOCATION D-1D-1 2'-6"3'-6"3'-6"3'-9"L-1 L-1 L-1 L-1 L-1 2'-6"2'-6"EQ2'-6"L-1 L-1 L-1EM 4'-6"4'-7" L-1L-1L-1 L-1EM L-1L-1 D-2 EQ 5'-1"5'-1"EQ D-2 D-2 WAP EQ2'-6"EQEQ9"9"ALIGN WITH (E) FIXTURE L-1 L-1 8'-0" 8'-0" L-1 8'-0"L-1EM EQEQEQ EQ L-1 7'-0" L-1EM 7'-0"EQEQCAM CAMB/CAM B WAP ALIGN WITH (E) FIXTURE WAP WAP SD SD SD SD SD SD SD SD SD SD SD B/CAM WOOD CEILING TO BE PAINTED TO MATCH NEW GWB CEILING PANT WOOD CEILING TO BE COVERED W/ GWB IN THIS AREA ENCAPSULATE POPCORN CEILING WITH (2) LAYER 1/4" GWB ON ALL EXISTING CEILINGS THAT APPLY, VERIFY LOCATIONS IN FIELD. PROVIDE LEVEL 4 FINISH SC-1 SC-1SC-1 E-4 EXISTING T-STAT TO REMAIN RELOCATE EXISTING T-STAT AS NEEDED TO ACCOMODATE NEW WALL MECH ROOM LIGHTING NOT IN SCOPE E-3 E-3E-3 E-3 E-3 E-3 E-3 E-4 E-4 E-5 E-6 E-4 E-1 E-2 E-4 E-1 E-3E-3 E-3 E-5 EXISTING T-STAT TO REMAIN RELOCATE EXISTING T-STAT AS NEEDED TO ACCOMODATE NEW WALL ETHERNET E-1 E-1 E-1 E-1 E-1 E-1 E-1 E-1 E-1 E-2 E-3 E-7 E-3E-3 E-1 E-1 E-1 E-1 E-1 EXISTING POPCORN CEILING TO REMAIN PATCH EXISTING CEILING WHERE DEMO'D WALLS OCCUR PATCH EXISTING CEILING WHERE DEMO'D WALLS OCCUR, TYP. PROVIDE A LEVEL 4 FINISH SALVAGE FOR REUSE SALVAGE FOR REUSE REMOVE SWITCH WOOD CEILING TO REMAIN IN THIS AREA SALVAGE RESTROOM EXHAUST FAN COVERS FOR REUSE, TYP SALVAGE ALL SUPPLY & RETURN AIR DIFFUSERS FOR REUSE, TYP LIGHT SWITCHES SHOWN ON THE DEMO RCP ARE FOR REFERENCE ONLY. ALL EXISTING SWITCHES SHALL BE REMOVED, WALLS PATCHED, AND NEW SWITCHES INSTALLED. E-4 1. ASBESTOS & HAZARDOUS MATERIALS: FEDERAL, STATE & LOCAL REGULATIONS REQUIRE THAT ALL ASBESTOS & OTHER HAZARDOUS MATERIALS IN A BUILDING BE REMOVED PRIOR TO STARTING THE DEMOLITION WORK. CONTRACTOR TO OBTAIN REQUIRED CERTIFICATION THAT THERE ARE NO HAZARDOUS MATERIALS PRESENT IN THE STRUCTURE. 2. U.O.N. ALL DEBRIS RESULTING FROM DEMOLITION WORK SHALL BECOME THE PROPERTY OF THE CONTRACTOR & SHALL BE REMOVED & DISPOSED OF IN A LEGAL MANNER OFF OF THE PROJECT PROPERTY. 3. ELECTRICAL & MECHANICAL PERMITS ARE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL COORDINATE DEMOLITION NEEDS. 4. THE CONTRACTOR SHALL PROTECT THE EXISTING BUILDING & IMPROVEMENTS WITHIN THE AREAS OF OPERATION & TAKE CARE TO PROTECT THE NEIGHBORING SPACES WHERE EXISTS. THE CONTRACTOR SHALL ASSUME ALL FINANCIAL RESPONSIBILITY FOR THE IMMEDIATE RESTORATION, REPAIR, OR REPLACEMENT OF DAMAGED ITEMS OR AREAS TO RESTORE THEM TO MATCH EXISTING CONDITIONS . DEMO RCP NOTES 1. ALL GWB SOFFITS AND CEILINGS TO BE PAINTED PT-1, FLAT FINISH, U.O.N. 2. HEIGHTS NOTED ARE ABOVE FINISHED FLOOR, U.O.N. 3. REFER TO INTERIOR ELEVATIONS FOR MOUNTING HEIGHT OF WALL SCONCES. 4. VERIFY LOCATIONS OF ACCESS PANELS WITH ABOVE CEILING DEVICES & CONTROLS - PAINT TO MATCH ADJACENT SURFACE. 5. ALL LIGHT FIXTURES TO BE 3000K, U.O.N 6. CONTRACTOR TO VERIFY ENERGY CODE COMPLIANCE AND PROVIDE ALL NECESSARY CODE REQUIRED ITEMS. RCP NOTES LIGHTING LEGEND = SWITCH = 3 WAY SWITCH = 4 WAY SWITCH S S S 3 4 = STANDARD DUPLEX OUTLET = (E) SURFACE MOUNT FLUORESCENT LIGHT FIXTURE = (E) CEILING MOUNT FLUORESCENT LIGHT FIXTURE, WOOD CASING = RECESSED CAN LIGHT FIXTURE = (E) HALLWAY SCONCE LIGHT FIXTURE = (E) BATHROOM SCONCE LIGHT FIXTURE, ROUND = (E) BATHROOM SCONCE LIGHT FIXTURE, RECTANGLE = (E) TRACK LIGHT = (E) FAN = (E) AIR REGISTER = (E) AIR RETURN = (E) COVERPLATE = SECURITY CAMERA PER CLIENTCAM = BUZZER WITH SECURITY CAMERA PER CLIENT B/CAM = WAP, PROVIDE DATA AND POWER IN CEILING FOR WIFI DEVICE SD SMOKE DETECTOR = BUZZERB Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:57:54 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057DEMO & NEW RCP A201 N 02'12'16' 4'8' N 02'12'16' 4'8' SCALE: 3/16" = 1'-0" NEW RCP1SCALE: 3/16" = 1'-0" DEMO RCP2 LIGHTING LEGEND MARK DESCRIPTION MFR / VENDOR MODEL COLOR / FINISH LAMPING / TEMP COMMENTS D-1 DECORATIVE PENDANT RICH BRILLANT WILLING GP-10G-PC30-30-120_TM_DEX-CPYB MATTE BLACK LED / 3000K MOUNT AT 6'-0" BOTTOM OF FIXTURE D-2 DECORATIVE PENDANT RICH BRILLANT WILLING CTF-18-PC30-30-277_10_DIN MATTE BLACK LED / 3000K SURFACE MOUNTED E-1 EXISTING FLUORESCENT LIGHT EXSITING REMOVE, PATCH AND REPAIR CEILING E-2 EXISTING FLUORESCENT LIGHT - WOOD EXISTING REMOVE, PATCH AND REPAIR CEILING E-3 EXISTING RECESSED CAN EXISTING REPLACE WITH L-1 PER PLAN E-4 EXISTING HALLWAY SCONCE EXISTING SALVAGE FIXTURES FOR RE-USE WHERE LOCATIONS ARE CHANGING E-5 EXISTING BATHROOM SCONCE - ROUND EXISTING REMOVE, PATCH AND REPAIR WALL E-6 EXISTING BATHROOM SCONCE - REC EXISTING REMOVE, PATCH AND REPAIR WALL E-7 EXISTING TRACK LIGHT EXISTING REMOVE, PATCH AND REPAIR CEILING L-1 RECESSED CAN LIGHT FOCAL POINT FLCS3, RO, 1300L, 30K, FL, 120V, LD1, IC. TRIM & LED MOD: LCS3,RO,AA,WH,WH WHITE LED / 3000K ACCENT ADJUSTABLE L-1EM RECESSED CAN LIGHT (EMERGENCY) FOCAL POINT FLCS3, RO, 1300L, 30K, FL, 120V, LD1, IC. TRIM & LED MOD: LCS3,RO,AA,WH,WH WHITE LED / 3000K EMERGENCY BACK-UP L-1W RECESSED CAN LIGHT (WET) FOCAL POINT FLCS3, RO, 1300L, 30K, FL, 120V, LD1, IC. TRIM & LED MOD: LCS3,RO,AA,WH,WH WHITE LED / 3000K WET RATED SC-1 BATHROOM SCONCE CEDAR AND MOSS AUDREY 6INCH, OPAL GLOBE, HARDWIRED MATTE BLACK WITH BRASS G16 LED WET RATED OFFICE 3 MECH 4 RECEPTION & LOUNGE 1 OFFICE 6 CONFERENCE & BREAKROOM 7 OFFICE 9 RESTROOM 10 OFFICE 11 OUTDOOR LOUNGE 2 RESTROOM 5 COPY 8 CNC-1 CPT-2 CNC-1 CNC-1 CNC-1 CPT-2 CPT-1 CPT-1 CPT-1 CPT-1 FP-1 FP-1 FP-1 FP-1 PT-2 CNC-2 CNC-2 WD-1 TL-1 SEE ELEVATIONS TL-3 TL-3 TL-1 PT-3 PT-3 PT-2 2 A810 2 A810 2 A810 1'-0"21'-0"1'-0"9'-9"1'-0"2 A810 2 A810 2 A810 12'-0"11'-6"4'-4"5'-2"WOOD BLINDS AT ALL WINDOWS A7004 Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:57:56 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057FINISH PLAN A202 N 02'12'16' 4'8' SCALE: 3/16" = 1'-0" FINISH PLAN1 PLUMBING FIXTURES & ACCESSORIES LEGEND MARK DESCRIPTION MFR / VENDOR MODEL / NAME COLOR / FINISH COMMENTS SINK-1 KITCHEN SINK KOHLER VAULT, K-25939-NA, UNDERMOUNT LARGE SINGLE-BOWL STAINLESS 32" x 18-5/16" x 5-7/9" FAUC-1 KITCHEN FAUCET KOHLER CRUE, K-22974, TOUCHLESS PULL-DOWN SINGLE HANDLE KITCHEN FAUCET VIBRANT STAINLESS TOLIET-1 TOILET AMERICAN STANDARD 2989101.020, CADET 3 FLOWISE WHITE LEFT FRONT LEVER LOCATION TOILET-2 TOILET AMERICAN STANDARD 2988813.020, CADET 3 FLOWISE WHITE RIGHT FRONT LEVER LOCATION SINK-2 BATHROOM SINK GROHE EUROCUBE, 39656000, WALL MOUNT 24" 1-HOLE SINK ALPINE WHITE PF-6 SINK SHROUD GROHE 39657000, WALL MOUNT SHROUD ALPINE WHITE FAUC-2 BATHROOM FAUCET KOHLER K-13472-CP, GOOSENECK TOUCHLESS FAUCET VIBRANT STAINLESS PF-7 FIXED SHOWER HEAD & CONTROL DELTA T217267-SS STAINLESS PF-8 SHOWER CONTROL DELTA T17067-SS ARA, MONITOR 17 SERIES, VALVE ONLY STAINLESS PAIR WITH R10000 ROUGH-IN VALVE PF-9 HAND HELD SHOWER DELTA 51799-SS-PR, UNIVERSAL SHOWERING H20KINETIC 3 SETTING, SLIDE BAR HAND SHOWER, LUMICOAT STAINLESS : 51799-SS-PR VIBRANT STAINLESS PA-1 TOILET PAPER DISPENSER DELTA 75950-SS, TRINSIC STAINLESS PA-2 SEAT COVER DISPENSER BOBRICK B-221.MBLK, SURFACE MOUNTED SEAT-COVER DISPENSER MATTE BLACK PA-3 SOAP DISPENSER DELTA 6746453, UME SOAP DISPENSER TALL BLACK PA-7 WALL HOOK WEST ELM 4402687, SIN UNI WALL HOOK BLACK PA-9 WALL SHELF - 24" WEST ELM 5022031, LINEAR BURNT WAX WOOD WALL SHELVES W/ JORDAN BRACKETS DARK BRONZE PA-10 CURTAIN ROD BOBRICK B-207 X 72, SHOWER CURTAIN ROD W/ CONCEALED MOUNTING CHROME PLATED PA-11 SHOWER SOAP DISPENSER SIMPLEHUMAN BT1034 SINGLE WALL MOUNT SOAP PUMP STAINLESS PA-12 SHOWER FOLDING SEAT FREEDOM SHOWERS APFSSB-280150PT, FOLDING SHOWER BENCH, PHENOLIC SLATTED TAK TEAK PA-13 GRAB BAR - 18" DELTA 41918, 18" ANGULAR MODERN DECORATIVE GRAB BAR MATTE BLACK PA-14 GRAB BAR - 24" DELTA 41924, 24" ANGULAR MODERN DECORATIVE GRAB BAR MATTE BLACK PA-15 GRAB BAR - 36" DELTA 41936, 36" ANGULAR MODERN DECORATIVE GRAB BAR MATTE BLACK PA-16 GRAB BAR - 42" DELTA 41942, 42" ANGULAR MODERN DECORATIVE GRAB BAR MATTE BLACK EQUIPMENT & APPLIANCE LEGEND MARK DESCRIPTION MFR / VENDOR MODEL / NAME COLOR / FINISH COMMENTS DISH FULLY INTEGRATED DISHWASHER MIELE G 5050 SCViI ACTIVE PLAM TO MATCH ADJACENT CABINETS FOIC, CONTRACTOR TO PROVIDE PLAM FACE PANEL MICRO MICROWAVE TBD STAINLESS FOIC REF REFRIGERATOR GE MODEL#: PWE23KYNFS STAINLESS FOIC FINISH SCHEDULE MARK DESCRIPTION VENDOR / MANUF MODEL SIZE LOCATION REMARKS CONTACTS CNC-1 CONCRETE N/A N/A N/A SEE FINISH PLAN ARCHITECTURAL GRADE SMOOTH CONCRETE W/ CLEAR COAT FINISH, LIGHT GRIND, PROVIDE MOCK-UP SAMPLE FOR APPROVAL CNC-2 CONCRETE N/A N/A N/A SEE FINISH PLAN ARCHITECTURAL GRADE SMOOTH CONCRETE W/ CLEAR COAT FINISH, LIGHT GRIND, PROVIDE MOCK-UP SAMPLE FOR APPROVAL CPT-1 CARPET INTERFACE FRENCH SEAMS, 105607 LYON 25CM X 1 METE PLANK OFFICES ASHLAR INSTALLATION, INSTALL PER MANF INSTRUCTIONS CPT-2 CARPET MILIKEN LAPIDUS, MANTLE, MAN132-171 SAPPHIRE 1 METER SQUARE MEETING & RECEPTION INSTALL PER MANF INSTRUCTIONS FP-1 ACOUSTICAL PANEL TRACK-MOUNTED FABRIC PANELS; 1" SQUARE EDGE BUTT JOINT, 1" ACOUSTICAL FIBERGLASS SUBSTRATE W/ MIN. 0.80 NRC. FABRIC: CASAMANCE, LOUANGE, 3778 04 52, UNBACKED, 55" WIDTH TRACK-MOUNTED FABRIC PANELS; 1/2" SQUARE EDGE BUTT JOINT, TACKABLE/ACOUSTICAL FIBERGLASS SUBSTRATE PER FABRIC WIDTH OFFICES PROVIDE SHOP DRAWINGS PRIOR TO INSTALL. ALIGN FABRIC PATTERN FROM PANEL TO PANEL. STAINLESS COVERPLATES AT FP-1 LOCATIONS MIR-1 WALL MIRROR WEST ELM STREAMLINE ROUNDED EDGE WALL MIRROR - BLACK 24"X36 RESTROOM PLM-1 PLASTIC LAMINATE WILSONART ACORN VELVET ELM 15602 PER MANF BREAKROOM VERTICAL GRAIN PLM-2 PLASTIC LAMINATE WILSONART SLATE VELVET 15507 PER MANF OFFICE PT-1 PAINT BENJAMIN MOORE OR SIM COLOR TO MATCH: BENJAMIN MOORE, OC-21 WINTER WHITE N/A WALLS AND CEILINGS U.O.N. EGGSHELL AT WALLS AND FLAT AT CEILING PT-2 PAINT (ACCENT) BENJAMIN MOORE OR SIM COLOR TO MATCH: BENJAMIN MOORE, HC-154 HALE NAVY N/A SEE ELEVATIONS EGGSHELL. STAINLESS COVERPLATES AT PT-2 LOCATIONS FINISH SCHEDULE MARK DESCRIPTION VENDOR / MANUF MODEL SIZE LOCATION REMARKS CONTACTS PT-3 PAINT (ACCENT) BENJAMIN MOORE OR SIM COLOR TO MATCH: BENJAMIN MOORE, HC-154 HALE NAVY N/A RESTROOMS GLOSS. STAINLESS COVERPLATES AT PT-3 LOCATIONS SS-1 SOLID SURFACE CAERSARSTONE 4001 FRESH CONCRETE 2CM BREAKROOM & RECEPTION DESK SS-2 SOLID SURFACE CAERSARSTONE 406 CLEAR SKIES 2CM OFFICE TL-1 FLOOR TILE TBD PROVIDE ALLOWANCE FOR $8 PER SQFT 8" SQUARE RESTROOM TL-3 FLOOR TILE TBD PROVIDE ALLOWANCE FOR $8 PER SQFT TBD RESTROOM WD-1 WOOD TBD IPE WOOD DECKING 4" PLANKS EXTERIOR DECK WD-2 WOOD SURFACING SOLUTIONS FLEXIBLE WOOD TAMBOUR PANELS, OAK, T438, 1" PANEL SIZE PER MANF RECEPTION DESK VERTICAL INSTALLATION WD-3 WOOD OAK STAIN GRADE OAK, STAINED TO MATCH WD-2 4" WIDE RECEPTION DESK WD-4 WOOD OAK STAIN GRADE OAK, STAINED TO MATCH WD-2 PER DRAWINGS RECEPTION SCREENS WDB WOOD BASE PAINT GRADE HARD WOOD 1X4 ALL LOCATIONS PAINT TO MATCH WALL NEW ADA RAMP. SLOPE 1:12 MAX LANDING 5'-1" LANDING 5'-0" RAMP 10'-0" UP3'-6"3 A500 0" AFF 10" AFF 36" CONTINUOUS HANDRAIL RETURN TO FLOOR TYP 1'-0"7'-8"1 1/2" MIN HANDRAILS TO HAVE CIRCULAR CROSS SECTION, OUTSIDE DIAMETER 1-1/4" MIN TO 2" MAX UP LANDING 5'-2" RAMP 13'-0" LANDING 5'-2"3'-11"0"AFF 19"AFF 19"AFF EXISTING DECK 3'-6"4 A500 NEW ADA RAMP SPLOPE 1:12 MAX 36" CONTINUOUS HANDRAIL RETURN TO FLOOR TYP 1'-0"1'-0" HANDRAILS TO HAVE CIRCULAR CROSS SECTION, OUTSIDE DIAMETER 1-1/4" MIN TO 2" MAX1 1/2" MIN1 1/2" MIN AFF10"HANDRAIL TYP36"T T T T TGAURDRAIL TYP42"RAILINGS CR LAURANCE ARS 200 SERIES RAILING SYSTEM, MATTE BLACK, TYP GLASS PANELS CR LAURANCE ARS ALUMINUM RAILING SYSTEM, TYP T 4"LANDING ALIGNED WITH (E) GRADE C.I.P. CONC, TYP MAX SLOPE 1:12, TYP COMPACTED GRAVEL BASE, TYP #5 AT 48" O.C., TYP #5 CONTINUOS, TYP C.I.P. CONC, TYP LANDING ALIGNED WITH (E) GRADE HANDRAIL TYP36"MAX SLOPE 1:12, TYP T T T T T T GAURDRAIL TYP42"4"2"4"RAILINGS CR LAURANCE ARS 200 SERIES RAILING SYSTEM, MATTE BLACK, TYP GLASS PANELS CR LAURANCE ARS ALUMINUM RAILING SYSTEM, TYP T COMPACTED GRAVEL BASE, TYP #5 AT 48" O.C., TYP #5 CONTINUOS, TYP 1. HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF EACH RAMP RUN. GRIPPING SURFACE SHALL BE CONTINUOUS, WITHOUT INTERRUPTION BY NEWEL POSTS, OTHER CONTSTRUCTION ELEMENTS, OR OBSTRUCTIONS. 2. HANDRAILS SHALL BE AT CONSISTENT HEIGHT ABOVE RAMP SURFACE AND WALKING SURFACES. 3. CLEARANCE BETWEEN HANDRAIL GRIPPING SURFACE AND ADJACENT SURFACES SHALL BE 1-1/2" MIN. 4. HANDRAILS WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF 1-1/4" MIN TO 2" MAXIUMUM. 5. HANDRAILS, AND ANY WALL OR OTHER SURFACES ADJACTENT TO THEM, SHALL BE FREE OF ANY SHARP OR ABRASIVE EELEMENTS. EDGES SHALL BE ROUNDED. 6. HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS. HANDRAIL & GUARDRAIL NOTES Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:57:57 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057EXTERIOR RAMPS A500 SCALE: 1/2" = 1'-0" ENLARGED PLAN - EXTERIOR ENTANCE RAMP1 SCALE: 1/2" = 1'-0" ENLARGED PLAN - EXTERIOR DECK RAMP2 SCALE: 1/2" = 1'-0" SECTION - EXTERIOR ENTANCE RAMP3 SCALE: 1/2" = 1'-0" SECTION - EXTERIOR DECK RAMP4 N N BASE CABINET WITH COUNTER 34"AFF SINKDISH 2'-0"30"X48" CLEAR FLOOR AREA FOR SINK & DISHWASHER A700 1 A700 3 A7002 CONFERENCE & BREAKROOM 7 REF A7004 OFFICE 9 COPY 8 UPPER CABINETS AND SHELVES ABOVE2'-5"30"X48" CLEAR FLOOR AREA FOR REFRIGERATOR2'-10"2'-2"2'-8"6'-8"MIN1'-0"PLM-1 CABINET DOORS TYP SS-1ALIGN END PANEL END PANEL TL-3 ALIGN W/ EDGE OF DWOPEN SHELVING PT-1 T R 3 A900 1 A900 1 A900 2 A900 5 A900 10"10"4 A900 T ALIGN REF DISHWASHER SINK-1 ALIGN 6 A900 FAUC-1 3'-0"1'-3"1'-3" PLM-1 VERIFY REQ'D R.O. 2'-1"1'-3"1" VERIFY REQ'D R.O. 3'-0"1"1'-6"1" MICRO MOCKETT, DP129 SERIES - ROUND TOP DRAWER PULL, SATIN STAINLESS STEEL, TYP 2" BLACK ACRYLIC LETTERS. USE INDUSTRIAL VELCRO TO ATTACH TO CABINETS PLM-1 TL-3 PLM-1 RECYCLE PULLOUT TRASH PULLOUT 1'-0"2'-8 1/2" 3'-11 1/2" WDB PLM-1 CONTRACTOR TO PROVIDE BACKING 60" MONITOR FOIC PROVIDE POWER AND DATA PER REQUIREMENTS, CORDINATE WITH AV CENTERED ON CONF TABLE 5'-11"5'-0"CLCL WDB SS-2 PLM-2 PT-2 2 A900 SIM DRAWER PULLS: MOCKETT, DP269 - 3" TAB DRAWER PULL, SATIN NICKEL. TYP 3'-3"3'-3"3'-3"END PANEL 1"9"4"4"7"7"7"1"6"1"1'-3"PLM-2 OPEN OPEN OPEN OPEN OPEN OPEN 10"1'-0"FILLER 1"2'-0"3'-3" 5 A900 4 A900 5'-0"PLM-1 PRINTER WDB Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:57:58 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057INTERIOR ELEVATIONS - CONFERENCE & OFFICE A700 SCALE: 1/2" = 1'-0" CONFERENCE ROOM 7 - PLAN5 SCALE: 1/2" = 1'-0" CONFERENCE 7 - KITCHENETTE1 SCALE: 1/2" = 1'-0" CONFERENCE 7 - WALL MONITOR2 SCALE: 1/2" = 1'-0" OFFICE 9 - CASEWORK3 SCALE: 1/2" = 1'-0" COPY 8 - UPPER CASEWORK4 N A701 2 A701 7 RECEPTION & LOUNGE 1 A701 3 A701 1 8 A701 A701 4 A701 2 SS-1 1'-10"1'-10" 1'-10"EQ EQ METAL GROMMETS IN DESK SURFACE. MOCKETT: PS-1C - 1-3/4" FLUSH MOUNT DESK GROMMET, 2 SLOTS, SATIN NICKEL CONVENIENCE OUTLET IN DESK SURFACE: MOCKETT, PCS49A/USBAC-95 - RECTANGULAR POWER/USBA+C ELECTRICAL IN CHASE WALL 3'-0"3'-6" 8 A701 3 1/2" 1'-3" 1'-3" 1'-6" 3/4" FP 7'-11 1/4" SS-1 LOCKABLE DOORS AND DRAWERS, TYP 1'-0" 6" 6"1'-0" 1'-0"4" 2'-0" 1 1/2" PLM-2 DRAWER PULLS: MOCKETT, DP254B - 7" TAB DRAWER PULL, ALUMNINUM. TYP FILE DRAWERS 8 A701 3a WD-2 WD-3 SS-1 RENTON AIRPORT 5" BLACK ACYRILIC LETTERS PIN MOUNTED 6"1 1/2"2'-1"3"2'-4"EQ EQ 3'-2"SCREENS IN FULLY OPEN POSITION WD-2 WD-3 SS-1 2'-5" 4'-1" TYP 8'-2" TYP 16'-3" 9 A701 FLOOR MOUNTED KEY LOCK TO SECURE PERFORATED PANEL IN PLACE. VENDOR TO COORDINATE REQ W / OWNER AND ARCH CUSTOM SCREENS. PERFORATED 1" THICK MDF. PAINT MDF SEE RENDERINGS ON A701-5 FOR DESIGN INTENT. ARCHITECT TO PROVIDE CAD DRAWINGS FOR FABRICATION. PROVIDE AN ALLOWNACE OF $7,000 FOR THE PANELS. WD-4 PT-2 WOOD FRAMES TYP 3"TYP3"SCREENS TO HAVE FLOOR GLIDES 4'-1" FLOOR MOUNTED KEY LOCK TO SECURE PERFORATED PANEL IN PLACE. VENDOR TO COORDINATE REQ W / OWNER AND ARCH CUSTOM SCREENS. PERFORATED 1" THICK MDF. PAINT MDF SEE RENDERINGS ON A701-5 FOR DESIGN INTENT. WD-4 PT-2 WOOD FRAMES WDB ELECTRICAL IN CHASE WALL SOLID SURFACE COUNTER PER ELEVATIONS 1 1/2"1" 3" CLEAR 2'-0" SOLID SURFACE SCREEN WOOD TAMBOURS APPLIED TO MDF PER MANF INSTRUCTIONS. PROVIDE WOOD FILLER TO MATCH TAMBOUR FINISH AT NAIL HOLES. 1"3"2'-1" PERFORATED SCREENS FOR REFERENCE SLIDING SCREEN SHIM 1x TRIM, PT TO MATCH DOOR3/8"RENDERING FOR REFERENCE ONLY TO SHOW SCREEN INTENTION, REFER TO DRAWINGS FOR INFORMATION Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:57:59 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057INTERIOR ELEVATIONS - RECEPTION A701 SCALE: 1/2" = 1'-0" RECEPTION PLAN6 SCALE: 1/2" = 1'-0" RECEPTION CASEWORK - INTERIOR7 SCALE: 1/2" = 1'-0" RECEPTION CASEWORK - LONG4 SCALE: 1/2" = 1'-0" RECEPTION CASEWORK - SHORT2 SCALE: 1/2" = 1'-0" RECEPTION SCREEN - LONG3 SCALE: 1/2" = 1'-0" RECEPTION SCREEN - SHORT1 SCALE: 1" = 1'-0" RECEPTION DESK - SECTION8SCALE: 3" = 1'-0" SLIDING SCREEN TRACK DETAIL9 SCALE: 1 1/2" = 1'-0" RECEPTION SCREENS5NOT TO SCALE, FOR REFERENCE ONLY N RESTROOM 5 ø 5' - 0"5' - 0"56"1' - 6"SEE 5/A102 FOR GRAB BAR AND ACCESSORY LOCATIONS 30"X48" CLEAR FLOOR AREA AT LAVATORY WALL MOUNTED SINK A702 11 7 6 12 RESTROOM 10 2'-9"1' - 6" 5'-0"56"2' - 6" 30"X48" CLEAR FLOOR AREA AT LAVATORY T SHAPE TURNING CLEARANCE 3' - 0"2' - 0"12"3' - 0" WALL MOUNTED SINK A702 1 4 85 A702 92'-6"1' - 3 3/4" 10 5'-0" TO FACE OF FINISH 1'-3"1"1"DRAIN ALONG WALL 2% SLOPETO DRAIN60" X 30" CLEAR FLOOR AREA AT SHOWER 2'-11"3'-6"5"3"3'-0"4"2'-10"PT-3 4'-0"MIR-1 5'-6"6" SC-1 TOILET-1 SINK-2 PF-6 FAUC-2 TL-1 PA-3 PA-2 SPACER REQUIRED BEHIND TOP OF GRAB BAR TO MATCH TILE THICKNESS 2'-0" MIN 1'-0" MIN PA-16 WDB 3'-4"3'-4"3'-6"1'-0" 8"3"2'-11"PA-13 PA-16 PA-1 TL-1 WDB 5 4'-0"2'-4" 10"1'-0"TO TOP OF HOOK3'-7"PA-9 PA-7 TL-1 WDB PT-3 TL-1 WDB PT-4 WDB 4'-0"TO TOP OF HOOK3'-7"2'-7" 1'-0"1'-1" 1'-0"1'-0"TO TOP OF HOOK3'-7"PA-9 PA-7PA-7 10 TL-1 WDB 3'-6"1'-0" 8"3"4'-0"PT-3 EXISTING WINDOW TL-1 PA-16 PA-1 WDB 3'-6"5"2'-11"3'-0"6"1'-6"3'-10"3'-2"1'-4"7'-0"2'-10"4'-0"FOLDING SHOWER SEAT TL-1 TL-1 PT-3 PT-3 MIR-1 CL 6"6" CENTER MIRROR ON SINK VIF NOTIFY ARCH W/ DISCREPANCY 7" SC-1 5'-7"SC-1 TOILET-2 PA-15 SINK-2 PF-6 FAUC-2 PA-3 PA-2 PA-16 1'-0" MIN 2'-0" MAX WDB PF-8 PF-9 2'-2" 3"2'-0"5"1'-6"2'-11"10 PA-14 PA-13 TL-13'-10"6'-7"EQ EQ PF-7 PF-7 7'-0"6'-11"1'-6"PA-12 TL-1 Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:58:03 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057INTERIOR ELEVATIONS - RESTROOMS A702 SCALE: 1/2" = 1'-0" ENLARGED PLAN - ADA RESTROOM 53SCALE: 1/2" = 1'-0" ENLARGED PLAN - RESTROOM 102 SCALE: 1/2" = 1'-0" RESTROOM 5 - NORTH7 SCALE: 1/2" = 1'-0" RESTROOM 5 - EAST11 SCALE: 1/2" = 1'-0" RESTROOM 5 - SOUTH12 SCALE: 1/2" = 1'-0" RESTROOM 5 - WEST6 SCALE: 1/2" = 1'-0" RESTROOM 10 - EAST1 SCALE: 1/2" = 1'-0" RESTROOM 10 - NORTH8 SCALE: 1/2" = 1'-0" RESTROOM 10 - SOUTH5SCALE: 1/2" = 1'-0" RESTROOM 10 - WEST4 SCALE: 1/2" = 1'-0" RESTROOM 10 - SHOWER9 SCALE: 1/2" = 1'-0" RESTROOM 10 - SHOWER SEAT10 N N PTD/WR TPD ABBREVIATIONS ACC.ACCESSIBLE CH COAT HOOK CT CERAMIC TILE DD DIAPER DISPENSER DR DIAPER RECEPTACLE FD FLOOR DRAIN FS FIXED SHELF FUS FOLDING UTILITY SHELF GB GRAB BAR PTD PAPER TOWER DISPENSER PTN PARTITION SCD SEAT COVER DISPENSER SD SOAP DISPENSER SND SANITARY NAPKIN DISPOSAL SNV SANITARY NAPKIN VENDOR TB TOWEL BAR TPD TOILET PAPER DISPENSER WR WASTE RECEPTACLE PTD/WR PAPER TOWEL DISP./ WASTE RECEPTACLE SNV PTD / HD 54"48" MAXTYPICAL NON-ACC.ACCESSIBLE6" REACH DEPTH 40"PTD / HD 48" MAXPAPER TOWEL DISPENSER AND HAND DRYERPER 309.3, 308PER 603.6MAX REACH DEPTH MAX REACH HEIGHT 0.5" 48" 2" 46" 5" 6" 9" 11" 42" 40" 36" 34" TABLE 603.6 PER TABLE SD HD HAND DRYER 48" MAX TO OPERABLE PART OF UNIT PROVIDED 1/2" MAX PROJECTION OF UNIT FROM WALL - TABLE 603.648" MAXWALL MOUNTED ACCESSORIES CHT CHANGING TABLE COAT HOOK 42" MAX 24" MIN 1 1/2" MINWALL MOUNTED PAPER TOWEL DISPENSER48" MAX12"24" MIN 36" MAX MIN7"- 9" DISPENSER OUTLET LOCATION (SHADED) PREFERRED LOCATION TPD 42" MAX 24" MIN RECESSED PAPER TOWEL DISPENSER48" MAX36" MAX DISPENSER OUTLET LOCATION (SHADED) 24" MIN CDU 1 1/2" MINSCD SCD 48" MAX30"18"MIN18"MINSEAT COVER DISPENSER REAR WALL SEAT COVER DISPENSER SIDE WALL FIGURE 604.7 FIGURE 604.7 CDU COMBINATION DISPENSER UNIT SIDE GRAB BARS REAR GRAB BARS WATER CLOSET33" - 36"54" MIN 42" MIN12" MAX 39" - 41"CL 39" - 41"18" MIN33" - 36"36" MIN 6" MAX 42" MIN 16" - 18" CL17" - 19"34"48" MAX20" MAX 34"44" MAX22"- 25"48" MAX15" MIN48" MAX34"10" MAX 46" MAX34"10.1"- 24" REACH AREA REACH AREA REACH AREA OBSTRUCTED SIDE REACH FIGURE 308.3.2 REACH AREA REACH AREA 48" MAX15" MIN10" MAX REACH AREA UNOBSTRUCTED SIDE REACH FIGURE 308.3.1 UNOBSTRUCTED FORWARD REACH FIGURE 308.3.1 OBSTRUCTED FORWARD REACH FIGURE 308.3.2 FAUCET PER WAC51-40,1106.7.5. MIRROR TO ADJ. WALL INSULATE OR COVER PER WAC 11-40, 1106.7.4. REFER TO PLUMBING SPECS 27"34" MAX40" MAX18" MIN MINT.O. HIGHEST POINT OF LAV. RIM OR COUNTER B.O. MIRROR REFLECTIVE SURFACE FIGURE C606.2 (a) CL 27"11" 6"10"8" ADA KNEE CLEARENCE 1. ACCESSORIES TO BE MOUNTED PER 3/A6.1. 2. LAVS AND COUNTERS TO COMPLY WITH ACCESSIBLE REACH LIMITS AND ACCESSIBLE VANITY HEIGHTS. 3. 5'-0" TURN RADIUS AND ALL CLEAR FLOOR AREAS SHALL BE MEASURED FROM FLOOR TO 27". 4. REFER TO PLUMBING FIXTURE SCHEDULE FOR SPECIFICATIONS OF ALL PLUMBING FIXTURES (LAVATORIES, WATER CLOSETS, URINALS, SHOWERS, DRAINS). 5. REFER TO ACCESSORIES SCHEDULE FOR ADDITIONAL SCOPE AND SIGNAGE SCOPE. 6. PER IBC REQUIREMENTS PROVIDE SMOOTH, NON-ABSORBENT MATERIAL UP TO 4FT AFF AT WET WALLS ADJACENT TO TOILET. GENERAL RESTROOM NOTES Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:58:04 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057ACCESSIBILITY PLANS & DETAILS A710 SCALE: 1/4" = 1'-0" ACCESSIBLE ACCESSORY MOUNTING HEIGHTS3 SCALE: 1/4" = 1'-0" ACCESSIBLE REACH LIMITS2 SCALE: 1/4" = 1'-0" ACCESSIBLE VANITY HEIGHTS1 DOOR LEGEND MATERIAL KEY HCW HOLLOW CORE WOOD SOLID WOOD CORE HOLLOW METAL WOOD/ GLASS METAL/ GLASS METAL SWC HM WG MG MTL GLASSGL ALUMINUMALUM FINISH KEY PAINTPT STAINST STAINLESS STEELSST FACTORY FINISHF FIN WOOD VENEERWV WOODWD VINYLVIN INSULATED HOLLOW METALIHM WOOD CARDBOARD COREWCC FIBERGLASS/ GLASSFG HANDLE FIRE STROBE WALL BASE RECEPTACLE TELE/DATA COVERPLATE FINISHED FLOOR CARD READER 1. 2. DOOR & FRAME PER SCHEDULE SWITCHPLATE -GANG PLATE AS POSSIBLE THERMOSTAT, VRFY LOCATION w/ MECH'L DWGS UNLESS SPECIFICALLY DIMENSIONED LOCATE ALL TELEPHONE & ELECTRICAL WALL OUTLETS & SWITCH PLATES AT THE NEAREST STUD. PROVIDE CLEAR FLOOR SPACE THAT ALLOWS A FORWARD OR SIDE APPROACH IN COMPLIANCE WITH 1CC/ ANSI A117.1 -2003 ADA GUIDELINES AT ALL CONTROLS & HARDWARE. FIRE EXTINGUISHER CAB. PER BLDG. STANDARD EXIT SIGN: PROVIDE PENDANT WHERE CLG. HUNG OR STRUCTURE EXCEEDS 8'-6"AFF.6'-8"CL 6"4'-0"TO OF TRIM3'-4"CL6"1'-6"HARDWARE GROUPS 1 LOCKSET - 3X BUTT HINGES - 1X LEVER LOCKSET - 1X WALL STOP 2 PRIVACY LOCKSET (NO INDICATOR) - 3X BUTT HINGES - 1X PRIVACY LOCKSET - 1X LEVER CLASSROOM LOCKSET - 1X WALL STOP - 1X ACOUSTICAL SWEEP - PERIMETER ACOUSTICAL BULB SEAL 3 PRIVACY LOCKSET - 3X BUTT PASSAGE - 1X PRIVACY LOCK \SET WITH OCCUPANCY INDICATOR - 1X WALL STOP - 1X ACOUSTICAL SWEEP - PERIMETER ACOUSTICAL BULB SEAL -1X MOP PLATE 10" X 27" BRONZE FINISH 4 PRIVACY LOCKSET - 3X BUTT PASSAGE - LOCKABLE DROP BOLTS - PROGRESSIVE HARDWARE CO INC. ITEM NO. R1000, BRONZE FINISH - 1X WALL STOP 1.ALL SWING DOORS TO BE LOCATED 4" OFF ADJACENT PARTITIONS AT HINGE SIDE U.O.N. 2. REFER TO PARTITION TYPES FOR JAMB THICKNESS. 3. ALL DOORS ALLOW EGRESS IN THE DIRECTION OF EGRESS TRAVEL. ALL DOORS IN THE MEANS OF EGRESS SHALL BE SINGLE ACTION RELEASE & SHALL NOT REQUIRE THE USE OF A KEY OR SPECIAL KNOWLEDGE FROM EGRESS SIDE. NO THUMB LATCHES OR KEYED CYLINDER DEAD BOLTS ALLOWED ON ANY DOORS IN EGRESS PATH. 4. UNDERCUT DOORS TO CLEAR THE TOP OF FINISH FLOORS, AS APPLICABLE, BY 1/4" MAXIMUM. VERIFY FLOOR CONDITIONS. 5. ALL DOORS SHALL HAVE 1'-6" CLR ON STRIKE/PULL SIDE OF DOOR. 7. ALL DOOR HARDWARE TO COMPLY WITH CURRNENT ADA. 8. VERIFY ALL HARDWARE & LOCKING REQ'S w/OWNER PRIOR TO ORDERING 9. CONFIRM KEYWAY REQUIREMENTS WITH OWNER. 10. ALL LEVER SETS TO BE SARGENT STUDIO / COLLECTION CENTRO SERIES / MD / CR ROSE, US10B FINISH 11. ANY DOOR HARDWARE, LOCKSET OR LATCH SET THAT IS BEING REUSED SHALL BE TESTED FOR PROPER OPERATION AND ANY REPAIRS NECESSARY SHALL BE MADE PRIOR TO OCCUPANCY. ALL SWING DOORS SHALL BE ADJUSTED TO MEET REQUIREMENT FOR MAX. 5 LB. PRESSURE FORCE TO OPERATE DOOR. DOOR & HARDWARE NOTES 12. NFRC U VALUES FOR ALL GLAZED EXTERIOR SLIDING DOOR SYSTEMS IS U=.30 MAX. U=.20 MAX AT ALL SWINGING AND PIVOTING EXTERIOR DOORS 13. CALCULATE INSTALLATION COSTS OF DOOR HARDWARE SEPARATELY 14.DIMENSIONS FOR SWINGING, PIVOTING, AND ALL INTERIOR DOORS ARE APPROXIMATE ACTUAL DOOR SIZES. VERIFY DOOR SIZES FOR ALIGNMENT OF ADJACENT DOOR AND WINDOW HEADERS AND JAMBS 15. DIMENSIONS FOR EXTERIOR MULTI-PANEL SLIDING DOORS ARE FOR ROUGH OPENING. T=TEMPERED GLAZING WD. DR. PER SCHED. 1/2" WD. SHIM WD. FRAME; ROUTE TO RECEIVE GWB R.O.3/4"3/4"5/8"PER WALL TYPE5/8"1 3/4"2 1/2"1/4" • SINGLE HINGED DOOR • 1 3/4" SOLID WOOD STILE & RAIL • 1/4" TEMPERED GLASS INSET • WOOD VENEER 2 A800 2 A800 3'-0"7'-0"3'-0" T A • SINGLE HINGED DOOR • 1 3/4" SOLID WOOD STILE & RAIL • WOOD VENEER B C T 3'-0" 6"6"6"10"8"6"1'-9"6"• SINGLE HINGED DOOR • 1 3/4" SOLID WOOD STILE & RAIL • 1/4" TEMPERED GLASS INSET • WOOD VENEER 3'-0"7'-0"7'-0"T T6"10"6"6" 3'-0" 3'-0"7'-0"D • DOUBLE HINGED DOOR • 1 3/4" SOLID WOOD STILE & RAIL • 1/4" TEMPERED GLASS INSET • WOOD VENEER 2 A800 Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:58:04 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057DOOR AND WINDOW SCHEDULE & DETAILS A800 DOOR AND FRAME SCHEDULE MARK TYPE DOOR FRAME FIRE RATING HDW SET NOTES LOCATIONMATL FIN SIZE MAT L FINWIDTH HEIGHT THK FINISH FLOOR 1a C WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 ELECTRIFIED, EXTERIOR DOOR, U FACTOR PER CODE REQ RECEPTION & LOUNGE 1b A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 ELECTRIFIED HALLWAY 1c A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 ELECTRIFIED, EXTERIOR DOOR, U FACTOR PER CODE REQ RECEPTION & LOUNGE 3a A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 RECEPTION & LOUNGE 3b A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 OFFICE 3c D WD CLR 6' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 4 OFFICE 5 B WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 3 RESTROOM 6 A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 OFFICE 7 A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 2 CONFERENCE & BREAKROOM 9 A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 OFFICE 10 B WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 3 RESTROOM 11 A WD CLR 3' - 0" 7' - 0" 0' - 1 3/4" WD CLR NA 1 OFFICE SCALE: 1/2" = 1'-0" TYPICAL MOUNTING HEIGHTS1 SCALE: 3" = 1'-0" JAMB DETAIL2 TYPE A UL #423 1HR *STC: 42 ACOUSTIC (1) LAYER GYPSUM WALL BOARD (GWB) SOUND ATTENUATION BLANKET* STEEL STUD STUD SIZE KEY 0 HAT CHANNEL 1 1 5/8" 2 2 1/2" 3 3 5/8" 4 4" 6 6" 8 8" 10 10" 1. GWB ON 25 GAUGE MTL STUDS @ 16" O.C. TYPICAL UON. INSTALL STEEL FRAMING TO COMPLY w/ ASTM C 754 & w/ ASTM C 840 REQ'S THAT APPLY TO FRAMING INSTALLATION. 2. ALL RATED & ACOUSTICAL PARTITION TO HAVE 5/8" TYPE "X" GWB TYPICAL UON. 3. PARTITION TYPES ARE ASSUMED TO END AT INTERSECTING WALLS WHERE RATED PARTITIONS INTERSECT NON-RATED PARTITIONS. THE RATED PARTITION IS ASSUMED TO CONTINUE UNINTERRUPTED. 4. ALL FIRE RATED AND SMOKE ASSEMBLY PARTITIONS EXTEND TO STRUCTURE, UON. 5. ALL THROUGH PENETRATIONS OF FIRE-RATED ASSEMBLIES SHALL BE INSTALLED AS TESTED PER CODE. 6. APPLY OR PATCH FIREPROOFING TO DECK ABOVE (WHERE OCCURS) AFTER INSTALLATION OF TOP TRACK OR MOUNTING PLATES. 7. APPLY ACOUSTIC SEALANT (WHERE OCCURS) TO FIREPROOFING (WHERE OCCURS) OR TO B.O. STRUCTURE. 8. FOR PARTITIONS EXTENDING TO CEILING OR ABOVE, PROVIDE BRACING ABOVE CEILING AS REQUIRED TO LIMIT DEFLECTION TO SPECIFIED ALLOWANCES. 9. ALL ACOUSTICAL PARTITIONS HAVE FULL WALL CAVITY R-11 BATT MIN. PARTITION TAG LEGENDGENERAL PARTITION NOTES 1. ALL ACOUSTICAL PARTITIONS HAVE FULL WALL CAVITY R-11 BATT MIN. 2. STAGGER JOINTS ON ALL MULTIPLE LAYERS OF GYPSUM BOARD. 3. ON WALLS TALLER THAN 10'-0" APPLY ONE LAYER HORIZONTALLY AND THE OTHER VERTICALLY. CONTRACTOR TO DETERMINE THE ORDER OF VERTICAL/ HORIZONTAL PLACEMENT. 4. CAULK ALONG BOTH SIDES OF THE PERIMETER WITH A NON-HARDENING SILICONE MASTIC. 5. AVOID BACK-TO-BACK OUTLETS. CAULK ALL OPENINGS IN ELECTRICAL BOXES. A MINIMUM OFFSET OF 18" WITH AT LEAST ONE STUD BETWEEN THE BOXES IS REQUIRED BETWEEN ELECTRICAL BOXES ON OPPOSITE SIDES OF A COMMON PARTITION WALL. 6. WHERE A DOUBLE ROW OF STUDS ARE USED MAKE NO CONNECTION BETWEEN THE ROWS. 7. WHERE A SOUND RETARDANT PARTITION ABUTS PERPENDICULARLY TO A CONTINUOUS GYPSUM BOARD PARTITION, INTERRUPT THE GYPSUM BOARD AT THE POINT OF INTERSECTION AND CAULK THE JOINT LIBERALLY. DO NOT CONTINUE THE GYPSUM BOARD BEHIND THE INTERSECTION STUD. 8. ALL OPENINGS AROUND DUCT OR PIPE PENETRATIONS SHALL BE SEALED WITH A NON- HARDENING SILICONE MASTIC ACOUSTICAL PARTITION NOTES EXISTING STRUCT, HEIGHT VARIES VIF. BRACING SUSPENDED CLNG WHERE OCCURS PARTIAL HEIGHT WALL REFER TO ELEV's REFER TO RCP's a b c d e6"6"f NON- RATED (REFER TO PLANS, NOT ALL CONFIGURATIONS USED) CONC SLAB PARTITION TAG LEGEND PARTITION TYPE CONFIGURATION (REFER TO KEY) STUD SIZE DESIGNATION (REFER TO KEY) PARTITION HEIGHT/HEAD CONDITION (REFER TO KEY) # DESIGNATES FIRE-RATING A3a ' ' DESIGNATES ACOUSTICAL PARTITION 2 XX10. ACOUSTICAL PARTITIONS TO BE CAULKED & SEALED AIRTIGHT. 11. INSTALL (DENS-SHIELD OR EQ) TILE BACKER BOARD AT ALL INTERIOR TILE FINISHES TYPICAL, SEE INTERIOR ELEVATIONS FOR LOCATIONS. 12. PROVIDE 5/8" WATER RESISTANT DRYWALL AT ANY WET WALLS. 13. WHEN METAL FRAMING CONTINUES PAST INTERMEDIATE STRUCTURES -AS IN MULTISTORY STAIR ENCLOSURES AND SIMILAR CONDITIONS -ATTACHMENT TO INTERMEDIATE STRUCTURE SHALL BE WITH A SLOTTED CONNECTION OR OTHER MEANS SO THAT STRUCTURAL DEFLECTION WILL NOT TRANSFER LOADS TO METAL FRAMING. 14. CUT STUDS 1/2" SHORT TO ALLOW 1/2" DEFLECTION & PROVIDE NESTED TRACK OR SLOTTED TRACK TO ALLOW 1/2" DEFLECTION. 15. HOLD FINISH MATERIALS 1/2" SHORT OF STRUCTURE ABOVE. DO NOT FASTEN TO TOP TRACK. FASTEN INTO STUDS ONLY. 16. ALL EXISTING SHELL AND CORE WALLS IN TENANT SPACE TO BE FINISHED PER FINISH SCHEDULE. ACOUSTIC SEALANT AT PERIMETER & AT ALL PENETRATIONS BOTTOM TRACK SET w/ FOAM TAPE POWER FASTENER AT 24" O.C. WITH 100 # PULLOUT MIN. BASE PER SCHEDULE GWB TO STRUCT OR CLNG ABV: -DEEP LEG TRACK ASSEMBLY -PROVIDE ACOUSTIC SEALANT FROM T.O. GWB TO STRUCT. -CONTINUE ACOUSTIC BATT TO STRUCT. SUSPENDED CLNG PER PLAN BATT INSUL1/2" MAXWD. BASE PER SCHEDULE; SCRIBE TO FLOOR WALL ASSEMBLY PER TYPE F.F. PER SCHEDULE 1X4 HARD WOOD WDB DIM.PT.DIM.PT.FUTURA BEVEL CAP (LVT 405 EBR2) CARPET SUBSTRATE EXISTING FINISH FLOOR Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:58:05 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057INTERIOR WALL ASSEMBLIES & DETAILS A810 1 1/2" = 1'-0"A810 4 PARTITION ATTACHMENT SCALE: 6" = 1'-0" WOOD BASE1 SCALE: 12" = 1'-0" GLUE DOWN CARPET TO EXISTING CONC2 MELAMINE ON 1/2" SUBSTRATE BACK F.F. MELAMINE ON 1/2" SUBSTRATE BACK CABINET SIDES AND BOTTOM: MELAMINE ON 3/4" SUBSTRATE BLACK MELAMINE ON 3/4" SUBSTRATE ADJ. SHELF BRACKET HOLES AT 2" O.C. VERTICALLY CABINET PULL AS SCHEDULED, SOFT CLOSE DOOR FRONTS; PLASTIC LAMINET STILE AND RAIL 2 1/2", DRAWER SIZES PER ELEVATIONS PER ELEVATIONSDRAWERS; MELAMINE INTERIOR FINISH W/ HEAVY DUTY, SOFT CLOSE, FULL EXTENSION SLIDES, TYP. DRWR. FRONTS; WOOD VENEER STILE AND RAIL 2 1/2", DRAWER SIZES PER ELEVATIONS CABINET SIDES AND BOTTOM: MELAMINE ON 3/4" SUBSTRATE WOOD BASE TO MATCH CABINET DRAWERS; MELAMINE INTERIOR FINISH W/ HEAVY DUTY, SOFT CLOSE, FULL EXTENSION SLIDES, TYP. DRWR. FRONTS; WOOD VENEER STILE AND RAIL 2 1/2", DRAWER SIZES PER ELEVATIONS MELAMINE ON 1/2" SUBSTRATE BACK CABINET SIDES AND BOTTOM: MELAMINE ON 3/4" SUBSTRATE WOOD BASE TO MATCH CABINET F.F. PER PLAN 1 1/2"1 1/2"STONE OR SOLID SURFACE COUNTER PER ELEVATIONS CAULK TO WALL BACKSPLASH MATERIAL PER ELEVATIONS APPLIED TRIM WHERE WOOD VENEER WALLCOVERING OCCURS F.F. SIDES AND BOTTOM: MELAMINE ON 3/4" SUBSTRATE MELAMINE ON 1/2" SUBSTRATE BACK SOLID SURFACE COUNTER AND NOSE ON 1" PLYWD. PULL-OUT FULL-HEIGHT DRAWER ON HEAVY DUTY FULL EXTENSION DRWR. SLIDE; SOFT CLOSE MECHANISM PLAM ON 3/4" SUBSTRATE BASE TO MATCH CAB. BACKSPLASH PER ELEVATIONS PER PLAN 1"1 1/2"4"2 1/2"PER ELEV.CABINET HARDWARE TO BE SELECTED BY ARCHITECT DOOR FRONTS; WOOD VENEER STILE AND RAIL 2 1/2", DRAWER SIZES PER ELEVATIONS 2"2"PER ELEVATIONS2"PER ELEVATIONSMIN 1'-2"WD-1 ON (3) 1/2" SUBSTRATE ALL SIDES 1/2" X 9" STEEL SUPPORT ROD WELDED TO CONCEALED 4" X 3 1/2" X 1/4" STEEL PLATE MECHANICALLY FASTENED TO BLOCKING UNDER CABINET LIGHT FIXTURE PER ELEVATION3/4"12" CLEAR 3/4" MELAMINE ON 1/4" SUBSTRATE BACK CAB. FRONTS; PLAM ON 3/4" SUBSTRATE ALL SURFACES MELAMINE ON 3/4" SUBSTRATE @ ALL INTERIOR SURFACES UNDER CABINET LIGHT FIXTURE1/2"LINE OF CEILING VALENCE TRIM, TYP PER ELEVATIONSPER ELEVATIONS2 1/2"NOTE: SEE INTERIOR ELEVATIONS FOR EXACT QUANITITY OF DRAWERS, DOORS, AND SHELVES REFRIGERATOR MELAMINE ON 1/2" SUBSTRATE BACK CABINET SIDES AND BOTTOM: MELAMINE ON 3/4" SUBSTRATE BLACK MELAMINE ON 3/4" SUBSTRATE ADJ. SHELF BRACKET HOLES AT 2" O.C. VERTICALLY CABINET PULL AS SCHEDULED, SOFT CLOSE DOOR FRONTS; PLASTIC LAMINET STILE AND RAIL 2 1/2", DRAWER SIZES PER ELEVATIONS Johnston Architects, PLLC 100 NE Northlake Way, Suite 200 Seattle, WA 98105 t 206.523.6150 f 206.523.9382 SHEET TITLE SHEET NO. 03.07.22 DRAWING ISSUE PERMIT SET DATE DESCRIPTION 10/17/2022 07.18.22 BID SET 10.17.22 BID SET RE-ISSUE 10/17/2022 12:58:05 PMRENTON MUNICIPAL AIRPORTOFFICE REMODEL243 W Perimeter RdRenton, WA 98057CASEWORK DETAILS A900 SCALE: 1 1/2" = 1'-0" TALL CABINET1 SCALE: 1 1/2" = 1'-0" BASE CABINET - DRAWERS2SCALE: 1 1/2" = 1'-0" BASE CABINET - TRASH & RECYCLE3 SCALE: 1 1/2" = 1'-0" OPEN SHELVING4 SCALE: 1 1/2" = 1'-0" CLOSED UPPERS5 SCALE: 1 1/2" = 1'-0" CABINET AT REF6