Loading...
HomeMy WebLinkAboutPre-app Mtg Summary - 22-000321.pdfCityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-Applications\2022\PRE22-000350 1 PRE-APPLICATION MEETING FOR Project Weekend PRE22-000321 CITY OF RENTON Department of Community & Economic Development Planning Division October 27, 2022 Contact Information: Planner: Alex Morganroth, 425-430-7219, amorganroth@rentonwa.gov Public Works Plan Reviewer: Michael Sippo, 425-430-7298, msippo@rentonwa.gov Fire Prevention Reviewer: Corey Thomas, 425-276-9582, cthomas@rentonrfa.org Building Official: Rob Shuey, 425-430-7290, rshuey@rentonwa.gov Please retain this packet throughout the course of your project as a reference. Consider giving copies of it to any engineers, architects, and contractors who work on the project. You will need to submit a copy of this packet when you apply for land use and/or environmental permits. Pre-screening: When you have the project application ready for submittal, call and schedule an appointment with the project manager to have it pre-screened before making all of the required copies. The pre-application meeting is informal and non-binding. The comments provided on the proposal are based on the codes and policies in effect at the time of review. The applicant is cautioned that the development regulations are regularly amended and the proposal will be formally reviewed under the regulations in effect at the time of project submittal. The information contained in this summary is subject to modification and/or concurrence by official decision-makers (e.g., Hearing Examiner, Planning Director, Development Services Director, Department of Community & Economic Development Administrator, Public Works Administrator and City Council). CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-Applications\2022\PRE22-000350 2 Renton Regional Fire Authority M E M O R A N D U M DATE: October 17, 2022 TO: Alex Morganroth, Senior Planner FROM: Corey Thomas, Lead Plans Review Inspector SUBJECT: Dees Short Plat 1. The fire flow requirement for a single-family home is 1,000 gpm minimum for dwellings up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to 1,500 gpm. There is one existing fire hydrant that meets minimum code. 2. The fire impact fees are currently applicable at the rate of $829.77 per single family unit. This fee is paid at building permit issuance. Credit will be given for the removal/retention of one single family home. 3. Fire department apparatus access roadways are required to be a minimum of 20-feet wide fully paved, with 25-feet inside and 45-feet outside turning radius. Fire access roadways shall be constructed to support a 30-ton vehicle with 75-psi point loading. Access is required within 150-feet of all points on the buildings. Maximum grade is 15 percent. Dead end street over 300-feet requires a full 90-foot diameter cul-de-sac which appears that it already exists. CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-Applications\2022\PRE22-000350 3 DEPARTMENT OF COMMUNITY & ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: October 26, 2022 TO: Alex Morganroth, Senior Planner FROM: Michael Sippo, Civil Engineer 3 SUBJECT: Utilities & Transportation Comments for Project Weekend 13250 84th Ave South PRE22-000321 NOTE: The applicant is cautioned that information contained in this summary is preliminary and non-binding and may be subject to modification and/or concurrence by official City decision-makers. Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. I have completed a preliminary review for the above-referenced proposal located at parcel(s) 2144800776. The following comments are based on the pre-application submittal made to the City of Renton by the applicant. WATER 1. The development is within the City of Renton’s water service area in the Earlington 370-hydraulic pressure zone. There is an existing 12-inch City water main in 84th Ave S (water plan Nos. W-0377 & W-0925) that can deliver a maximum flowrate of 2,800 gallons per minute (gpm). The static water pressure ranges from about 68 psi at ground level elevation 216. 2. There is an existing 3/4-inch domestic service to 13250 84th Ave S. 3. Based on Renton Regional Fire Authority’s review comments on the submitted information for the pre- application, the fire flow requirement for a single-family home is 1,000 gpm minimum for dwellings up to 3,600 square feet (including garage and basements). If the dwelling exceeds 3,600 square feet, a minimum of 1,500 gpm fire flow would be required. A minimum of one fire hydrant is required within 300-feet of the proposed buildings and two hydrants if the fire flow goes up to 1,500 gpm. There is one existing fire hydrant that meets minimum code. 4. The following water system improvements will be required as part of the development: a. Installation of additional fire hydrants as required by the Renton Regional Fire Authority. The final location and number of the hydrants shall be determined by the Fire Authority based on the final site plan. b. Installation of a separate domestic water meter and service line (minimum 1-inch in size) to each new residential unit. c. The existing 3/4-inch domestic water service may be reused, if feasible. The existing ¾-inch water service shall be cut and capped. 5. Installation of a “Storz” adapter on the existing hydrants, if they are not already equipped with one. 6. A conceptual utility plan will be required as part of the land use application for the subject development. CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-Applications\2022\PRE22-000350 4 7. Civil plans for the water main improvements will be required and must be prepared by a registered professional engineer in the State of Washington. A civil plan showing the preliminary water services to the proposed residences and/or additional hydrants shall be submitted with the land use application. 8. Adequate separation between utilities is required. Minimum separation between water and all other utilities is 10-feet horizontal and 1.5-feet vertical. 9. The development is subject to applicable water system development charges (SDC’s) and meter installation fees based on the number and size of the meters for domestic uses and for fire sprinkler use. The development is also subject to fees for water connections, cut and caps, and purity tests. Current fees can be found in the 2022 Development Fees Document on the City’s website. Fees that are current will be charged at the time of construction permit issuance. a. The SDC fee for water is based on the size of the new domestic water to serve the project. The current water fee for a single 1-inch meter is $4,500.00 per meter. b. A water system redevelopment credit will apply for the existing water meters if they are abandoned. c. Water service installation charges for each proposed domestic water service is applicable. Water Service installation for a 1-inch water service line is $2,875.00* per service line. This is payable at construction permit issuance. d. Drop-in meter fee is $460.00* per meter for a 1-inch meter. This is payable at issuance of the building. e. Final determination of applicable fees will be made after the water meter size has been determined. SDC fees are assessed and payable at construction permit issuance. SEWER 1. Sewer service is provided by City of Renton. 2. There is an 8-inch wastewater main located in 84th Ave S at the site’s southwest corner that flows south and then turns east within a public utility easement along the northern property lines of the adjacent 214480- 0800 and 214480-0804 properties to the south (S-293903). 3. The existing residence at 13250 is connected to the existing sewer main via side sewer connection to the sewer main located on the adjacent properties to the south. 4. The following wastewater system improvements will be required as part of the development: a. Installation of approximately 250 lineal feet of 8” sewer main in 84 th Ave S to the north from MH6139 to the northern extent of the site’s western property line. b. A separate side sewer will be required for each residence. All new sewer stubs shall be a minimum of 6” and shall run at a slope of at least 2% to the main. 5. The development is subject to a wastewater system development charge (SDC) fee. SDC fee for sewer is based on the size of the new domestic water to serve the project. The current sewer fee for a 1-inch meter install is $3,500.00 per meter. A sewer system redevelopment credit will apply for the existing sewer service. 6. The Earlington Sewer Interceptor Special Assessment District fee (SAD) fee will be applicable on the project. The SAD fee rate when it was established in 2009 was $7,366.22 plus interest per lot that did not grant easements (Zone B). As of 10/26/2022, the SAD fee rate per lot is $11,270.32 with no additional interest since the SAD has reached its maximum assessment. SURFACE WATER 1. A drainage report complying with the current version of the City’s adopted 2022 Renton Surface Water Design Manual (RSWDM) will be required. Based on the City’s flow control map, the site falls within the Flow Control Duration Standard area matching Forested Site Conditions and is within the West Lake Washington Drainage Basin. Refer to Figure 1.1.2.A – Flow chart to determine the type of drainage review required in the RSWM. 2. The site contains regulated slopes that range from moderate to severe. The site topography generally slopes moderately from west to east where there is a large valley and stream channel that encumbers the majority CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-Applications\2022\PRE22-000350 5 of the site along the northeast portion. There is an 18-inch stormwater main in 84th Ave S that discharges into the stream along the property from the north to south east and a 24-inch corrugated metal culvert that crosses underneath 84th Ave S and discharges into the stream onsite (record drawing SWP2703472). The Applicant will need to ensure that these conveyance systems and the stream is protected. 3. Detailed plans for any proposed cut and fill operations shall be submitted. These plans shall include the angle of slope, contours, compaction and retaining walls. 4. Maximum retaining wall height is 6-ft from finished grade. Based on the site topography, terraced retaining walls may be needed for the development. Retaining walls over 4-feet in height from footing require a separate building permit. 5. Maintenance access is required for any proposed stormwater tract and shall be designed and installed in accordance with the City adopted SWDM. 6. Storm drainage improvements along all public street frontages are required to conform to the City’s street and stormwater conveyance standards. Any new storm drain installed on or off-site shall be designed and sized in accordance with standards found in Chapter 4 of the 2022 RSWDM and shall account for the total upstream tributary area, assuming developed conditions for onsite tributary areas and existing conditions for any offsite tributary areas. 7. If the new plus replaced pollution generating impervious surface exceeds 5,000 SF, the applicant will be required to provide water quality treatment. Basic water quality treatment will be required for parcels with single family (including duplex) land use, while enhanced basic water quality treatment will be required for parcels with commercial or multifamily land use. Any proposed detention and/or water quality vault shall be designed in accordance with the RSWDM that is current at the time of civil construction permit application. Separate structural plans will be required to be submitted for review and approval under a separate building permit for the detention and/or water quality vault. 8. Appropriate on-site BMPs satisfying Core Requirement #9 will be required to help mitigate the new runoff created by this development to the maximum extent feasible. On-site BMPs shall be evaluated as described in Section C.1.3 of the 2022 RSWDM. A preliminary drainage plan, including the application of on-site BMPs, shall be included with the land use application, as applicable to the project. The final drainage plan and drainage report must be submitted with the utility construction permit application. 9. Effective June 22, 2022, the City of Renton has adopted the 2022 RSWDM, which is based on the 2021 King County SWDM. Under the new 2022 RSWDM stormwater requirements, on-site BMP sizing credits for modeling credits can no longer be used for privately maintained on-site BMPs, with the exception of full dispersion and full infiltration BMPs. 10. A Construction Stormwater Permit from Department of Ecology is not required as clearing and grading of the site will likely not exceed 1 acre. 11. A geotechnical soils report for the site is required per the 2022 Renton Surface Water Design Manual Section C.1.3. Information on the water table and soil permeability (measured infiltration rates), with recommendations of appropriate on-site BMPs per Core Requirement #9 and Appendix C shall be included in the report. The report should also include information concerning the soils, geology, drainage patterns and vegetation present shall be presented in order to evaluate the drainage, erosion control and slope stability for site development of the proposed plat. The applicant must demonstrate the development will not result in soil erosion and sedimentation, landslide, slippage, or excess surface water runoff. 12. Erosion control measures to meet the City requirements shall be provided. 13. The current City of Renton Surface Water Standard Plans that shall be used in all drainage submittals are available online at the City of Renton website. https://edocs.rentonwa.gov/Documents/Browse.aspx?id=990403&dbid=0&repo=CityofRenton. 14. The 2022 Surface water system development fee is $0.84 per square foot of new impervious surface, but no less than $2,100.00 for each new lot. This is payable prior to issuance of the construction permit. This fee is subject to change based on the calendar year the construction permit is issued. TRANSPORTATION CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-Applications\2022\PRE22-000350 6 1. The proposed development fronts Renton Ave S along the north property lines and 84th Ave S along the west property line. Renton Ave S is classified as a Minor Arterial Road and contains 4 travel lanes and a variable width buffer lane with sidewalks on each side. The existing ROW width is approximately 78 feet. To meet the City’s complete street standards for minor arterial streets, minimum ROW is 91 feet (4 lanes) and 103 feet (5 lanes). The project will be required to construct the following frontage improvements to continue the Earlington Townhomes project to the north along the entire Renton Ave S frontage: a. 12.5 feet of ROW dedication. b. Due to the critical areas located on the northern portion of the parcel and extreme elevation difference between the southern sidewalk on Renton Ave S and the subject property, the City Transportation and Development Review departments have determined that the City will support a fee-in-lieu of frontage improvements, see the City Fee schedule for a cost per frontage foot ($/LF). 84th Ave S is classified as a Residential Access Street. The existing ROW width varies between 66 (primary frontage) and 108 feet and intersects Renton Ave S at an acute angle. To meet the City’s complete street standards for residential access streets, minimum ROW width is 53 feet. Based on final survey there appears adequate right of way width and the existing road is located in a manner that allows for frontage improvements to be constructed within the existing prism. Pending the results of the final survey, additional right-of-way dedication does not appear to the required. a. The half street section will include 13’ pavement, 0.5’ curb, 8’ planter and 5’ sidewalk. b. Half street improvements will need to include a sidewalk around the western portion of the cul-de- sac connecting to the stairs that lead to Renton Ave S. 2. Per City code 4-6-060, frontage improvements for 84th Ave S shall include a 0.5-foot curb, an 8-foot planting strip, a 5-foot sidewalk, street trees and storm drainage improvements. 3. Per City code 4-6-060, frontage improvements for Renton Ave S shall include a 0.5-foot curb, an 8-foot planting strip, an 8-foot sidewalk, 2 foot clear space, street trees and storm drainage improvements. As mentioned previously, the City will support a fee-in-lieu of frontage improvements due to critical areas and the steep elevation drop behind Renton Ave S. 4. Current City of Renton standards require a turnaround for dead-end streets greater than 150 feet. a. Dead-end streets exceeding 300-feet must utilize a cul-de-sac meeting the requirements for emergency services access, including a 45-foot radius. Reference RMC 4-6-060H. The existing cul- de-sac shall be approved by Fire and Emergency Services. 5. Street grades shall not exceed 15 percent. 6. ADA access ramps shall be installed at all street crossings. Ramps shall be shown at each intersection. Ramps shall be oriented to provide direct pedestrian crossings. 7. Shared driveways are allowed for access to up to 4 lots provided at least one of the four (4) lots abuts a public right-of-way, with at least sufficient frontage to comply with the zoning width dimensions, and the subject lots are not created by a subdivision of ten (10) or more lots. Refer to the shared driveway requirements as outlined in RMC 4-6-060J. 8. Refer to City code 4-4-080 regarding driveway regulations: a. Driveways shall be designed in accordance with City standard plans 104.1 and 104.2. b. Maximum driveway slope is 15%. Driveways which exceed 8% shall provide slotted drains at the lower end with positive drainage discharge to restrict runoff from entering the garage. c. The maximum width of a single loaded garage driveway is 9-feet and the maximum width of a double loaded garage driveway is 16-feet. If a garage is not present, the maximum driveway width is 16-feet. d. Driveways shall not be closer than 5-feet to any property line. 9. Street trees are required to meet current city standards. 10. A traffic impact analysis is required when the estimated vehicular traffic generated from a proposed development exceeds 20 vehicles per hour in either the AM (6:00 – 9:00) or PM (3:00 – 6:00) peak periods. The analysis must include a discussion on traffic circulation to and from the site and onsite traffic CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-Applications\2022\PRE22-000350 7 circulation. The study shall include trip generation and trip distribution for the project for both AM and PM peak hours. 11. Paving and trench restoration shall comply with the City’s Trench Restoration and Overlay Requirements. 12. The transportation impact fee is based on the type of land use. For a single family dwelling, the 20 22 transportation impact fee is $10,861.69. Transportation impact fees are subject to change based on the year the building permit is applied for. GENERAL COMMENTS 1. All existing and proposed utility lines (i.e. electrical, phone, and cable services, etc.) along property frontage or within the site must be underground. The construction of these franchise utilities must be inspected and approved by a City of Renton inspector. 2. Maximum exposed retaining wall height is 6-ft and shall be setback a minimum of 3-ft from the right-of- way as outlined in RMC 4-4-040 – Fences, Hedges and Retaining Walls. 3. Adequate separation between utilities as well as other features shall be provided in accordance with code requirements: a. 7-ft minimum horizontal and 1-ft vertical separation between storm and other utilities is required with the exception of water lines which require 10-ft horizontal and 1.5-ft vertical. b. The stormwater line should be minimum 5 feet away from any other structure or wall or building. c. Trench of any utility should not be in the zone of influence of the retaining wall or of the building. 4. All civil construction permits for utility and street improvements will require separate plan submittals. All utility plans shall confirm to the Renton Drafting Standards. A licensed Civil Engineer shall prepare the civil plans. Please visit the Development Engineering Forms page for the most up-to-date plan submittal requirements: http://rentonwa.gov/business/default.aspx?id=42473 5. A landscaping plan and tree retention shall be included with the civil plan submittal. Each plan shall be on separate sheets. 6. A demo permit is required for the demolition of the existing building(s). The demo permit shall be acquired through the building department. 7. Fees quoted in this document reflect the fees applicable in the year 2022 only and will be assessed based on the fee that is current at the time of the permit application or issuance, as applicable to the permit type. Please visit www.rentonwa.gov for the current development fee schedule. CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-Applications\2022\PRE22-000350 8 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT M E M O R A N D U M DATE: October 27, 2022 TO: Preapplication File No. 22-000321 FROM: Alex Morganroth, Senior Planner SUBJECT: Project Weekend General: We have completed a preliminary review of the pre-application for the above-referenced development proposal. The following comments on development and permitting issues are based on the pre-application submittals made to the City of Renton by the applicant and the codes in effect on the date of review. The applicant is cautioned that information contained in this summary may be subject to modification and/or concurrence by official decision-makers (e.g., Hearing Examiner, Community & Economic Development Administrator, Public Works Administrator, Planning Director, Development Services Director, and City Council). Review comments may also need to be revised based on site planning and other design changes required by City staff or made by the applicant. The applicant is encouraged to review all applicable sections of the Renton Municipal Code. The Development Regulations are available online at https://www.codepublishing.com/WA/Renton. Zoning Requirements: The property is located within the Residential High Density (RHD) land use designation and the Residential-10 (R-10) zoning designation. Density Requirements: There are no minimum net density requirements for townhouse development in the R-14 zone. The density of the parent site shall not exceed the maximum net density of the zone. Only one dwelling unit shall be located on a unit lot. The Residential High Density Land Use designation is intended to create new units where access, topography, and adjacent land uses create conditions appropriate for a variety of housing unit types, or where there is existing multifamily development. The area of public and private streets (including driveway tracts) and critical areas (excluding buffers) would be deducted from the gross site area to determine the “net” site area prior to calculating density. In order to calculate the proposed density of the project, any area of public road, private easement, and/or critical area dedication must be known. The gross site area is approximately 0.33 acres. Based on the gross site area of 0.93 acres, fourteen (14) dwelling units would result in a gross density of 15 du/ac (14 units / 0.93 acres = 15 du/ac). The proposed gross density of 15 du/ac greater than the maximum density permitted in the R-14 zone. Allowed density Development Standards: The project is subject to RMC 4-2-110A, “Development Standards for Residential Zoning Designations” effective at the time of complete application (noted as “R-10 standards” herein). Individual unit lots created for townhouses and cottage house developments are exempt from the following standards of RMC 4 -2- 110A, Development Standards for Residential Zoning Designations (Primary and Attached Accessory Structures): maximum net density, minimum lot size, minimum lot width, minimum lot depth, yard setbacks, maximum building coverage, and maximum impervious surface area. Residential Design Standards – see RMC 4-2-115 for a complete list of standards and requirements. Significant Tree Retention: Application materials identify that there are mature trees on the site. When significant trees (greater than 6-inch caliper or 8-caliper inches for alders and cottonwoods) are proposed to be removed, a CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-Applications\2022\PRE22-000350 9 tree inventory and a tree retention plan along with an arborist report, tree retention plan and tree retention worksheet shall be provided with the formal land use application as defined in RMC 4-8-120. The tree retention plan must show preservation of at least 30% of significant trees. Please refer to RMC 4-4-130, Tree Retention and Land Clearing Regulations for further general and specific tree retention and land clearing requirements. In addition to retaining a minimum of 30% of existing significant trees, each new lot would be required to provide a minimum tree density of 30 tree credits per net acre. Tree credits encourage retention of existing significant trees with larger trees being worth more tree credits. TREE SIZE TREE CREDITS New small species tree 0.25 New medium species tree 1 New large species tree 2 Preserved tree 6 – 9 caliper inches 4 Preserved tree 10 – 12 caliper inches 5 Preserved tree 12 – 15 caliper inches 6 Preserved tree 16 – 18 caliper inches 7 Preserved tree 19 – 21 caliper inches 8 Preserved tree 22 – 24 caliper inches 9 Preserved tree 25 – 28 caliper inches 10 Preserved tree 29 – 32 caliper inches 11 Preserved tree 33 – 36 caliper inches 12 Preserved tree 37 caliper inches and greater 13 Significant trees shall be retained in the following priority order: Priority One: Landmark trees; significant trees that form a continuous canopy; significant trees on slopes greater than twenty percent (20%); significant trees adjacent to critical areas and their associated buffers; significant trees over sixty feet (60') in height or greater than eighteen inches (18") caliper; and trees that shelter interior trees or trees on abutting properties from strong winds, which could otherwise allow such sheltered trees to be blown down if removed. Priority Two: Healthy tree groupings whose associated undergrowth can be preserved; other significant native evergreen or deciduous trees; and other significant non-native trees. Priority Three: Alders and cottonwoods shall be retained when all other trees have been evaluated for retention and are not able to be retained, unless the alders and/ or cottonwoods are used as part of an approved enhancement project within a critical area or its buffer. CityofRenton\Department Folders\Community and Economic Development (CED)\Current Planning\Pre-Applications\2022\PRE22-000350 10 The Administrator may require independent review of any land use application that involves tree removal and land clearing at the City's discretion. The Administrator may authorize the planting of replacement trees on the site if it can be demonstrated to the Administrator's satisfaction that replacement requirements in RMC 4-4-130H1e can be met. Tree retention standards shall be applied to the developable area, as defined in RMC 4-11-040, Definitions D, of a property. A formal tree retention plan and tree retention worksheet prepared by an arborist or landscape architect would be reviewed at the time of the land use application. Fences/Retaining Walls: If the applicant intends to install any fences as part of this project, the location must be designated on the landscape plan. A wall taller than four feet requires a building permit. Fences up to six-feet in height are permitted in the rear yard and side yard; fences up to four feet are permitted in the front yard. Any part of a yard that is within a clear vision area has a limited fence height of 42 inches. A fence shall not be constructed on top of a retaining wall unless the total combined height of the retaining wall and the fence does not exceed the allowed height of a standalone fence. New or existing fencing would need to comply with the fence requirements of the code (RMC 4-4-040). Retaining walls shall be composed of brick, rock, textured or patterned concrete, or other masonry product that complements the proposed building and site development. There shall be a minimum three-foot (3') landscaped setback at the base of retaining walls abutting public rights-of-way. Please refer to retaining wall standards (RMC 4-4-040) for additional information about fences and retaining walls. Access/Driveways: Driveways shall not be closer than 5 feet to any property line and not exceed 40 percent of the street frontage. The width of any driveway shall not exceed 30 feet. The maximum driveway slopes cannot exceed 15%. If the grade exceeds 15%, a variance is required. Driveways exceeding 8% shall provide slotted drains at the lower end with positive drainage discharge to restrict runoff from entering the residences or crossing any public sidewalks. Alley access is the preferred street pattern for all new residential development except in the Residential Low Density (RLD) land use designation (RC, R-1, and R-4 zones) and the R-6 zone. All new residential development in an area that has existing alleys shall utilize alley access. New residential development in areas without existing alleys shall utilize alley access for interior lots. Primary access for individual unit lots may be from a public alley. The shared driveways shown on the site plan would not be a permitted access option for the proposed townhomes. Unit Lot Drives: Unit lot drives may be constructed to serve unit lot subdivisions. Each unit lot drive may serve up to nine (9) unit lots and shall be accessed by a public street. The paved roadway shall be a minimum of sixteen feet (16') wide with curbing, although the Fire Department may require the paved roadway to be up to twenty feet (20') wide. There shall be an eight foot (8') wide landscaping strip between the curb and a five foot (5') wide sidewalk along one side of the unit lot drive. The city may elect to have a unit lot drive dedicated as a public roadway; however, the City may require the unit lot drive to be privately. Critical Areas: A Type Ns stream is located on the project site. A stream study is required.