HomeMy WebLinkAboutMFP22001295.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP22001295
IVR Number: 22001295
Permit Information
Permit Name: COMCAST JB 956118 / ER Span Replacement
Address/Location:03/16/2022Application Date:7227801025Parcel Number: 960 HARRINGTON AVE NE
Permit Type:03/16/2022Issue Date:Franchise
Permit Work Class:03/16/2023Expiration Date:Minor Utility
Job Number: JB 956118Franchise Type:Cable
Description: REVISION: ROUTE MOVED FROM SIDEWALK TO THE ROAD HARRINGTON AVE NE. SEE SITE PLANS FOR
DETAILS. Comcast to tie in at pull 208 feet of coax through existing conduit from NE corner of Sunset & Harrington,
going south and ending at vault on SW corner. Then Comcast to bore in and place new 2" conduit from vault going
150' South to ped at 935. This job address is for 935 Harrington Ave NE. Comcast JB 956118
Contacts
Name Address PhoneTypeBilling
Michele Moore
Prince Telecom LLC
13701 24th St E, 24th St E
Sumner, WA 98390
H: (206) 388-4316ApplicantX
Andrew Parker
Comcast
410 Valley Ave NW, Suite 12 Bldg C
Puyallup, WA 98371
B: (253) 225-0596Applicant
Akisha Brown
Prince Telecom Inc
551A Mews Dr
New Castle, DE 19720
B: (302) 482-8893
C: (302) 482-8892
Contractor
Business License Number: 29850Electrical Contractor: PRINCTL834BF
Construction Contractor: PRINCTL862PS
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Page 1 of 1 | Published: 2/1/2018
Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200
Email: franchisepermits@rentonwa.gov Website: rentonwa.gov
REVISION - FRANCHISE PERMIT APPLICATION
Published: 2/1/2018
TO THE APPLICANT: Only Current Issued Permits Qualify for a Revision. For any work related to an expired
or finaled permit, a new Franchise Permit Application shall be required. Submit an electronic copy of the
plans with the Revision Franchise Permit Application to franchisepermits@rentonwa.gov.
Permit #
Franchise Agency:
Franchise Job Number: Phone:
Contact Name: Email:
Job Site Address: Project Name:
Approved Description of Work:
Proposed Description of Work:
Reason for change of work:
“I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ”
Signature Date
INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE
INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM
Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at
$125/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date.
Plan Review/Development Engineering Date Approved as submitted
Pre-Construction Meeting required
Site Construction Inspector Date Approved with comments or redlines
Camera inspection of utilities required
Development Engineering Manager Date
MFP22001295
Comcast Cable
JB 956118 253-225-0593
Andrew Parker- Comcast / Michele Moore- Prince andrew_parker2@comcast.com Michele.moore@prince telecom.com
935 Harrington Ave NE JB 956118
Contactor to work In ROW to pull cable though existing conduit from vault at NE corner of Harrington & Sunset,to SW corner. The then bore in new 2" conduit, going South to splice point.
Revised route will move new conduit from sidewalk Eastward onto Harrington Ave NE. Restoration
will be to Renton standard. All substructure to have 36" cover
There is no room on the side of the road to make the required separation between utilities
8/31/2022Michele L Moore
Scott Warlick 9/14/2022 POTHOLE ALL EXISTING UTILITIES
RESTORATION PER CITY OF RENTON STANDARDS
DEPARTMENT OF PUBLIC WORKS
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 1 of 2 | Published: 11/25/2019
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN (TCP) APPLICATION
Published: 11/25/2019
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL NO LATER THAN FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a TCP and
obtain City of Renton's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
TO THE APPLICANT: Submit the TCP application form and required submittal documents to
TCP@rentonwa.gov with the subject line “TCP Application – [Project Name]” or the above address.
The following items, electronic copies preferred, are all required for submittal of the TCP Application:
1.☐ A copy of the Traffic Control Plan (TCP) Application form.
2.☐ A copy of the required TCP layout, preferred 11” X 17” paper size format, which shall:
☐Include map(s) showing the location of the project and work area.
☐Be legible lettering and clear, contrasting, symbols of viewing or printing.
☐Must indicate street names, and north arrow and scale.
☐All signs and detour routes shall conform to the MUTCD, WSDOT TCPs, and the Washington State
Traffic Control Flagger Certification handbook, by the Evergreen Safety Council.
☐Types of plans required:
☐Work hour plan – show all mobility impacts during construction hours.
☐Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
☐Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
☐Pedestrian access/detour plan, if applicable.
Project Name: ______________________________________________ Permit #: _____________________
Project Address: ____________________________________________________________________________
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Description of Work, Work Schedule, Equipment Used: _____________________________________________
___________________________________________________________________________________________
___________________________________________________________________________________________
Construction Company: ________________________________________ Phone/Cell: (_____) _____-________
Applicant Name: _________________________________ Email: ______________________________________
Business Address: _________________________________ City/State: __________________ Zip: __________
Approved By: _______________________________________________ Date: ________________________
Transportation Operations Engineering
COMCAST JB 956118
935 HARRINGTON AVE NE RENTON WA 98056
Monday Friday 8AM 3PM
Contractor to park in ROW to pull coax cable through
existing conduit,then bore in 250'of new.
Prince Telecom LLC 206 388 4316
Michele Moore -Lead Permit Coordinator .Michele.moore@princetelecom.com .
13701 24th ST E Bldg G .Sumner 98390
MFP22001295
Scott Warlick CED 3/16/2022
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 2 | Published: 11/25/2019
APPLICANT AGREES TO ALL THE FOLLOWING:
•TCP must be approved prior to commencing the work, and all permit conditions shall be met.
•Existing pedestrian access shall be maintained. The work on pedestrian facilities shall be limited to one corner
at a time, with the least possible inconvenience or delay to pedestrians.
•Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or
slippery road conditions during work and non-work hours.
•The start of Work Time begins when any street or travel lane is fully/partially closed or impacts the follow of
traffic. This includes set up within the traveled way or immediately adjacent to the roadway.
•Emergency services (253-852-2121) shall be notified twenty-four (24) hours before any street or lane closures.
•Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including
public transit, to be affected by a temporary lane or road closure.
•TCP for all street and/or lane closures shall be implemented and performed in compliance with the Manual on
Uniform Traffic Control Devices (MUTCD) and/or State of Washington Department of Transportation (WSDOT)
and all traffic regulations of the City of Renton and Revised Code of Washington (RCW).
•Any lane or street closures not in conformance with the approved traffic control plan and/or without
notification of emergency services may result in receiving a citation for violation of RCW 47.36.200 Signs or
Flaggers at thoroughfare work sites and RCW 9A.36.050 Reckless Endangerment, and other applicable State
and City codes.
•Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles
and the acts of the Applicant’s agents and employees.
•The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and
in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s
reasonable attorney’s fees and litigation costs incurred resulting from such claim.
•In the event any claim or suit is brought against the City within the scope of this Agreement, Applicant will pay
for legal counsel chosen by the City to defend against same.
•Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
•Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
•Approved Temporary TCP must be at the work site during work hours.
•Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
•Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a
company logo or any legally acceptable sign showing the company name, address, and telephone number at a
conspicuous place on the vehicle or equipment.
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
•Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations
for vacate parking or curb lane usage.
•Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
•The cover sheet of this TCP form must be attached to each Temporary No Parking Sign on the project site.
•Temporary traffic control devices must be removed immediately when work is done or no construction
activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance
shop (3555 NE 2nd Street; 425-430-7423).
_______________________________ _______________________________ _______________________
Applicant’s Signature Print Name Date
Michele Moore -Permit Coordinator 3/16/2022Michele L Moore
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐ Electronic Copy of the TCP Application
☐ Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
Prince Telecom LLC
Michele Moore - Permit Lead 206-388-4316
13701 24th St E Bld G Sumner WA 98390
JB 956118 MFP22001295
935 Harrington Ave NE Renton
Monday-Friday 1 day 8AM 3PM
Requesting to bore 36' in r/w and place 2" PVC. Begin at pole on Southeast corner of 1175 Harrington Pl NE
boring 36' Southwest to private property. Utility crossing to be potholed to ensure required separation is maintained, locations to be identified at pre con inspection. All substructures have a 36 inch cover.
Scott Warlick CED 11/14/2022
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
11/3/2022
Michele Moore
KENNY'S TRAFFIC ZONE PLANSTRAFFIC CONTROL PLAN PREPARATION
PH # 425-223-7689TRAFICPLAYR@AOL.COMLongview, Wa STOP
KENNY STERTZTRAFFIC CONTROL SUPERVISOR
Washington Oregon
((ID# WA016416 SJ833BD.O.E 03/29/2026 5/31/2024
TYPICAL PROTECTIVEVEHICLE TYPEWITH TMA
TYPICAL PROTECTIVE VEHICLE(WITH TMA) LOADED WEIGHT(LBS)
STATIONARYOPERATION(ft)
30 MIN.
100 max.
MINUMIM WEIGHT 16000 LBS(MAXIMUM WEIGHT SHALL BE IN ACCORDANCEWITH MANUFACTURER RECOMMENDATION
4 YARD DUMP TRUCKSERVICE TRUCKFLAT BED, ETC
PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE
LONGITUDINAL BUFFER SPACE = B
ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT
A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE IF NO TMA IS USED,THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS ANDNO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION
CHANNELIZING DEVICE SPACING CHART (FEET)
50/70
35/45
20/30
mph *Half-Spacing*TAPER TANGENT
20
N/A
40
30
20
80
60
40N/A
BUFFER DATALONGITUDINAL BUFFER SPACE = B
SPEED (mph)
LENGTH (ft)
25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
MINIMUM TAPER LENGTH = L (feet)
POSTED SPEED (mph)
25 30 35 40 45 50 55 60 65 70
LANEWIDTH(feet)
1011
12
105115
125
150165
180
205225
245
270
295
320
450
495540
500
550600
550605660 660720
-----780 840
SIGN SPACING = X (FEET) (1)
FREEWAYS & EXPRESSWAYS
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS and URBAN ARTERIALS
RURAL ROAD, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
55/70 mph
60/65 mph
45/55 mph
35/40 mph
25/30 mph
25mph or less
1500ft +/-
800ft +/-
500ft +/-
350ft +/-
200ft +/-(2)
100ft +/-(2)
(1) All spacing may be adjusted to accomodate interchange ramps, at-grade
intersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions.
MERGING, SHIFTING, and SHOULDER TAPER LENGTHSand NUMBER OF CHANNELIZATION DEVICES USED
10ft LANE 11ft LANE 12ft LANE
L L L1/2L 1/2L 1/2L
Lanewidth
MPH Merging Merging MergingDevicesShiftingDevicesDevicesDevicesDevices DevicesShiftingShifting
SHOULDER TAPERS(assume 10ft shoulders)
1/3L Devices(FT)LengthMPH
2025
303540
455055
606570
70105150
205270450500550
600650700
66881016
1415161719
355575105135225250275300
325350
3455698899
10
75115165225295495
550605660715
770
679
911181516181920
406085115150250285305330370385
34556989
91011
80125180245320540600660720780840
6710
912191618
192122
406590125160270300330
360390420
34556
109910
1112
2025303540
455055
606570
2535
507090150170185200220235
33
3446
6667
7
Shoulder tapers equalsshoulder Width x Speed/3 ROADWORKAHEADW20-1100'ANe 12th St
1175
sidewalkRow boresidewalkNO PARKING7 AM -6 PM
FROM TO
TOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555
R7-T38<36'>cones -
NORTH
NOT TO SCALE
Harrington Pl NeDriveway
Pole -
Prince telecom
telecommunications
installation
Christie Walker
253-891-2899
JOB # JB0001045065
SPOTTER -parkingparkingparkingparkingFENCING
ROAD CLOSED
-Spotter will be onsite to guide any
Pedestrians pass the work area
NOTES :
-No Parking signs shall be placed 24hrs in advance of work-Sidewalk shall remain open
www.invarion.com
NORTH
NOT TO SCALE
Harrington Ave NeNe Sunset BlvdONLYONLY Ne 10th StONLYONLYPrince telecom
telecommunications
installation
Michele Moore
206-388-4316
JOB # JB956118
ROADWORKAHEADW20-1
350'
A
ROADWORKAHEAD W20-1100'AROADWORKAHEADW20-1100'A<150'>sidewalkSIDEWALK CLOSEDAHEAD
CROSS HERER9-11SIDEWALK CLOSEDAHEADCROSS HERER9-11TYPICAL PROTECTIVEVEHICLE TYPEWITH TMA
TYPICAL PROTECTIVE VEHICLE(WITH TMA) LOADED WEIGHT(LBS)
STATIONARYOPERATION(ft)
30 MIN.
100 max.
MINUMIM WEIGHT 16000 LBS(MAXIMUM WEIGHT SHALL BE IN ACCORDANCEWITH MANUFACTURER RECOMMENDATION
4 YARD DUMP TRUCKSERVICE TRUCKFLAT BED, ETC
PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE
LONGITUDINAL BUFFER SPACE = B
ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT
A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE IF NO TMA IS USED,THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS ANDNO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION
CHANNELIZING DEVICE SPACING CHART (FEET)
50/70
35/45
20/30
mph *Half-Spacing*TAPER TANGENT
20
N/A
40
30
20
80
60
40N/A
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (mph)
LENGTH (ft)25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
MINIMUM TAPER LENGTH = L (feet)
POSTED SPEED (mph)25 30 35 40 45 50 55 60 65 70
LANEWIDTH(feet)
101112
105115125
150165180
205225245
270
295
320
450
495
540
500
550
600
550605
660
660
720
-----780 840
SIGN SPACING = X (FEET) (1)
FREEWAYS & EXPRESSWAYS
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS and URBAN ARTERIALS
RURAL ROAD, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
55/70 mph
60/65 mph
45/55 mph
35/40 mph
25/30 mph
25mph or less
1500ft +/-
800ft +/-
500ft +/-
350ft +/-
200ft +/-(2)
100ft +/-(2)
(1) All spacing may be adjusted to accomodate interchange ramps, at-gradeintersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions.
MERGING, SHIFTING, and SHOULDER TAPER LENGTHSand NUMBER OF CHANNELIZATION DEVICES USED
10ft LANE 11ft LANE 12ft LANE
L L L1/2L 1/2L 1/2L
Lanewidth
MPH Merging Merging MergingDevicesShiftingDevicesDevicesDevicesDevices DevicesShiftingShifting
SHOULDER TAPERS(assume 10ft shoulders)
1/3L
Devices(FT)LengthMPH
2025303540455055606570
70105150205270450500550600650700
668810161415161719
355575105135225250275300325350
345569889910
75115165225295495550605660715770
679911181516181920
406085115150250285305330370385
3455698991011
80125180245320540600660720780840
6710912191618192122
406590125160270300330360390420
345561099101112
2025303540
455055606570
2535507090150170185200220235
33344666677
Shoulder tapers equalsshoulder Width x Speed/3
X
X
cones -
SIDEWALKCLOSED
R9-9
NO PARKING7 AM -6 PMFROMTOTOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555
R7-T38
splice
Tie in atexcisting -
point X
SIDEWALK CLOSEDAHEAD
CROSS HERER9-11-Minimum 10' Lanes-Sidewalk shall be closed
NOTES :
-No Parking signs shall be placed 24hrs
in advance of work
ROADWORKAHEADW20-1350'AKENNY'S TRAFFIC ZONE PLANSTRAFFIC CONTROL PLAN PREPARATION
PH # 425-223-7689TRAFICPLAYR@AOL.COMLongview, Wa STOPKENNY STERTZTRAFFIC CONTROL SUPERVISORWashington Oregon
((ID# WA016416 SJ833BD.O.E 03/29/2026 5/31/2024parkingparkingparkingparkingwww.invarion.com
NORTH
NOT TO SCALE
Harrington Ave NeNe Sunset BlvdONLY205' taper
ONLYNe 10th StONLYONLYPrince telecom
telecommunications
installation
Michele Moore
206-388-4316
JOB # JB956118
350'ABC350'350'W4-2RIGHT LANECLOSEDAHEADW20-5ROADWORKAHEADW20-1ROADWORKAHEADW20-1
350'
A
ROADWORKAHEAD W20-1100'AROADWORKAHEADW20-1100'Aparking<150'>conduitexisting
sidewalkSIDEWALK CLOSEDAHEAD
CROSS HERER9-11SIDEWALK CLOSEDAHEADCROSS HERER9-11parkingparkingparking
TYPICAL PROTECTIVEVEHICLE TYPEWITH TMA
TYPICAL PROTECTIVE VEHICLE(WITH TMA) LOADED WEIGHT(LBS)
STATIONARYOPERATION(ft)
30 MIN.
100 max.
MINUMIM WEIGHT 16000 LBS(MAXIMUM WEIGHT SHALL BE IN ACCORDANCEWITH MANUFACTURER RECOMMENDATION
4 YARD DUMP TRUCKSERVICE TRUCKFLAT BED, ETC
PROTECTIVE VEHICLE WITH TMA ROLL AHEAD DISTANCE
LONGITUDINAL BUFFER SPACE = B
ROLL AHEAD STOPPING DISTANCE ASSUMES DRY PAVEMENT
A PROTECTIVE VEHICLE IS RECOMMENDED REGARDLESS IF A TMA IS AVAILABLE IF NO TMA IS USED,THE PROTECTIVE VEHICLE SHALL BE STRATEGICALLY LOCATED IN THE FIELD TO SHIELD WORKERS ANDNO ROLL AHEAD DISTANCE IS SPECIFIED. REFER TO CHAPTER 1.5.5 FOR ADDITIONAL INFORMATION
CHANNELIZING DEVICE SPACING CHART (FEET)
50/70
35/45
20/30
mph *Half-Spacing*TAPER TANGENT
20
N/A
40
30
20
80
60
40N/A
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (mph)
LENGTH (ft)25 30 35 40 45 50 55 60 65 70
155 200 250 305 360 425 495 570 645 730
MINIMUM TAPER LENGTH = L (feet)
POSTED SPEED (mph)25 30 35 40 45 50 55 60 65 70
LANEWIDTH(feet)
101112
105115125
150165180
205225245
270
295
320
450
495
540
500
550
600
550605
660
660
720
-----780 840
SIGN SPACING = X (FEET) (1)
FREEWAYS & EXPRESSWAYS
RURAL HIGHWAYS
RURAL ROADS
RURAL ROADS and URBAN ARTERIALS
RURAL ROAD, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTS
URBAN STREETS
ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED
55/70 mph
60/65 mph
45/55 mph
35/40 mph
25/30 mph
25mph or less
1500ft +/-
800ft +/-
500ft +/-
350ft +/-
200ft +/-(2)
100ft +/-(2)
(1) All spacing may be adjusted to accomodate interchange ramps, at-gradeintersections, and driveways.(2) This spacing may be reduced in urban areas to fit roadway conditions.
MERGING, SHIFTING, and SHOULDER TAPER LENGTHSand NUMBER OF CHANNELIZATION DEVICES USED
10ft LANE 11ft LANE 12ft LANE
L L L1/2L 1/2L 1/2L
Lanewidth
MPH Merging Merging MergingDevicesShiftingDevicesDevicesDevicesDevices DevicesShiftingShifting
SHOULDER TAPERS(assume 10ft shoulders)
1/3L
Devices(FT)LengthMPH
2025303540455055606570
70105150205270450500550600650700
668810161415161719
355575105135225250275300325350
345569889910
75115165225295495550605660715770
679911181516181920
406085115150250285305330370385
3455698991011
80125180245320540600660720780840
6710912191618192122
406590125160270300330360390420
345561099101112
2025303540
455055606570
2535507090150170185200220235
33344666677
Shoulder tapers equalsshoulder Width x Speed/3
X
XX
X <105'><103'>
Lighted -
arrow board
KENNY'S TRAFFIC ZONE PLANSTRAFFIC CONTROL PLAN PREPARATION
PH # 425-223-7689TRAFICPLAYR@AOL.COMLongview, Wa STOP
KENNY STERTZTRAFFIC CONTROL SUPERVISOR
Washington Oregon
((ID# WA016416 SJ833BD.O.E 11/21/2022 5/31/2024cones -
SIDEWALKCLOSED
R9-9
NO PARKING7 AM -6 PMFROMTOTOW AWAY AREAPHONE 685-5444YOUR COMPANY NAME 555-5555
R7-T38
splice
Tie in atexcisting -
point X
SIDEWALK CLOSEDAHEAD
CROSS HERER9-11-Minimum 10' Lanes-Sidewalk shall be closed
NOTES :
-No Parking signs shall be placed 24hrs
in advance of work
www.invarion.com
MFP22001295
PRINCE TELECOM LLC Construction Manager:Scott Barker Engineer Larry Thurmond
13701 24TH ST E BLD G Permit Coordinator Michele.moore@princetelecom.com Site Contact #2 Larry Thurmond
SUMNER WA 98390 Comcast Permit Contact:Sandra Castro Job Type SPAN REPLACEMENT
•
•
•
•
•
•
•
935 HARRINGTON AVE NE
PERMIT INFORMATION JOB ADDRESS:
FROM TIE IN POINT, BORE IN AND INSTALL NEW 2"
PVC
Water Storm
Communication Sewer
TIE IN AT EXISTING SPLICE POINT.
Ped/ Vault
New UG New Aerial
PROJECT DISCRIPTION
PULL COAX CABLE THROUGH.
Total New conduit 150
RENTON WA 98056
SITE PLAN CONTRACTOR INFORMATION
JB 956118
Total existign conduit 208
PROJECT ID:
LEGEND
Existing UG Existing Aerial
Work Area
EXISTING UTILITIES
Power Gas
Tie in Pole
GENERAL NOTE:
•ALL SUBSTRUCTURE TO HAVE 36" COVER.
•RESTORATION SHALL COMPLY TO JURISDICTION STANDARD.
•CONTRACTOR TO COMPLY WITH ALL PROVISIONS OF LAW AND
ORDINANCES GOVERNING THIS WORK AND WITH ALL STATE AND
LOCAL LAWS AND ORDINANCES.
UTILITY DISCLAIMER
ALL LOCATIONS OF UTILITIES SHOWN AREAPPROXIMATE. LOCATION OF ALL UTILITIESTO BE VERIFIED PRIOR TO CONSTRUCTION.CALL UTILITY
UNDERGROUND LOCATION
CENTER AT 1-800-424-5555
PROPOSED PATH DISCALIMERS
1. PROPOSED PATH MAY CHANGE AT TIME OF
CONSTRUCTION DUE TO UTILITY LOCATIONS
AND INSPECTOR REQUIREMENTS
2. UNKNOWN UTILITY DEPTHS TO BE VERIFIED IN
FILED DURING TIME OF CONSTRUCTION
SPLICE
POINT
105 LF
EXISTING
VICINTIY MAP
103 LF
EXISTING
150' NEW CONDUIT
ROUTE MOVED TO
HARRINGTON AVE
SPLICE
POINT
SPLICE
POINT
SPLICE
POINT
MFP22001295
REVISED ROUTE MOVED
INTO HARRINGTON AVE
POTHOLE ALL EXISTING UTILITIES
RESTORATION PER CITY OF RENTON STANDARDS
PRINCE TELECOM LLC Construction Manager:Scott Barker Engineer Larry Thurmond
13701 24TH ST E BLD G Permit Coordinator Michele.moore@princetelecom.com Site Contact #2 Larry Thurmond
SUMNER WA 98390 Comcast Permit Contact:Sandra Castro Job Type:SPAN REPLACEMENT
•
•
•
•
•
•
•
Total UG: 150
Total Aerial: 208
TIE IN AT EXISTING SPLICE POINT.
PULL COAX CABLE THROUGH.
FROM TIE IN POINT, BORE IN AND INSTALL NEW 2"
PVC
0
0
0
0
Gas
Water Storm
Communication Sewer
RENTON WA 98056
PROJECT ID: JB 956118
LEGEND
Ped/ Vault Tie in Pole
New UG New Aerial
Existing UG
PROJECT DISCRIPTION
Existing Aerial
Work Area
EXISTING UTILITIES
Power
STREET VIEW CONTRACTOR INFORMATION PERMIT INFORMATION JOB ADDRESS:
935 HARRINGTON AVE NE
GENERAL NOTE:
•ALL SUBSTRUCTURE TO HAVE 36" COVER.
•RESTORATION SHALL COMPLY TO JURISDICTION STANDARD.
•CONTRACTOR TO COMPLY WITH ALL PROVISIONS OF LAW AND
ORDINANCES GOVERNING THIS WORK AND WITH ALL STATE AND
LOCAL LAWS AND ORDINANCES.
UTILITY DISCLAIMER
ALL LOCATIONS OF UTILITIES SHOWN AREAPPROXIMATE. LOCATION OF ALL UTILITIESTO BE VERIFIED PRIOR TO CONSTRUCTION.CALL UTILITY
UNDERGROUND LOCATION
CENTER AT 1-800-424-5555
PROPOSED PATH DISCALIMERS
1. PROPOSED PATH MAY CHANGE AT TIME OF
CONSTRUCTION DUE TO UTILITY LOCATIONS
AND INSPECTOR REQUIREMENTS
2. UNKNOWN UTILITY DEPTHS TO BE VERIFIED IN
FILED DURING TIME OF CONSTRUCTION
SPLICE
POINT
110'
ROW
BORE
110'
ROW
BORE
REVISED ROUTE MOVED INTO
HARRINGTON AVE REVISED ROUTE MOVED
INTO HARRINGTON AVE