Loading...
HomeMy WebLinkAboutT-42280800 N N O z 0 N Q Q 0 J / J / 0 Q U / 00 0 N O N O N O N U N O L n / U O L / U) W / Q) L 0 i / N L.� z i O N C O !1 / E O U LO / / w Q z W J I LEGEND ® ELECTRICAL SERVICE CABINET in PULL BOX TYPE 2 - - CONDUIT OLUMINAIRE SCHEDULE NOTE 0 WIRING SCHEDULE NOTE LED ROADWAY LUMINAIRE AND DECORATIVE POLE EXISTING LED ROADWAY LUMINAIRE AND DECORATIVE POLE NO. GENERAL NOTES 1. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE WSDOT/APWA STANDARD PLANS, STANDARD SPECIFICATIONS, LATEST AMENDMENTS TO THE STANDARD SPECIFICATIONS, CITY OF RENTON STANDARD DETAILS, SPECIAL PROVISIONS, AND THESE PLANS. 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL CONTACT THE PSE REPRESENTATIVE AT 1-888-321-7779 PRIOR TO INSTALLATION OF METER BASE. 4. FOR SIGNAL & ILLUMINATION SYSTEMS COORDINATION WITH THE CITY OF RENTON, CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE DEPARTMENT REPRESENTATIVE ERIC CUTSHALL AT (425) 430-7423. 5. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR ARE FOR GRAPHICAL PRESENTATION ONLY. FINAL LOCATIONS SHALL BE VERIFIED BY THE ENGINEER IN THE FIELD PRIOR TO INSTALLATION. 6. ALL NEW FOUNDATION LOCATIONS SHALL BE APPROVED BY THE ENGINEER PRIOR TO EXCAVATION. 7. ALL NEW JUNCTION BOXES SHALL HAVE SKID RESISTANT LIDS AND FRAMES. 8. ALL LUMINAIRE WIRING AND CONDUIT BETWEEN POLE AND JUNCTION BOX SHALL BE INSTALLED PER CITY OF RENTON STANDARD PLAN 119. 9. ALL NEW CONDUIT SHALL BE INSTALLED IN CITY OF RENTON RIGHT-OF-WAY. 10. EXISTING SIGNAL AND LIGHTING CONDUIT MAY HAVE LESS THAN 121, OF COVER. CONTRACTOR SHALL USE CAUTION WHEN EXCAVATING NEAR EXISTING CONDUIT. 11. FOR ADDITIONAL GENERAL NOTES SEE CITY OF RENTON STANDARD PLAN 135. 12. FOUNDATION DESIGN FOR LIGHT POLES REQUIRE GEOTECHNICAL ANALYSIS TO DETERMINE DEPTH OF FOUNDATION PER CITY STD DETAIL 117.1A CONSTRUCTION NOTES 1. INSTALL STANDARD EEL LIGHT PER STANDARD PLAN C.O.R STANDARD PLAN 117.1 2. INSTALL GHT STANDARD FOUNDATION PER STANDARD PLAN C.O.R STANDARD PLAN AA Poles are aluminum 3. INSTALL ELECTRICAL SERVICE CABINET PER C.O.R STANDARD PLAN 122.1 AND 122.2 AT APPROXIMATE STATION11+91, 35.24. COORDINATE WITH PSE FOR SERVICE CONNECTION. LABEL BACK OF CONTRACTOR CABINET WITH ADDRESS LOCATION, USE 1" LETTERS 4. INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD LUMINAIRE # POLE ID # CIRCUIT # STATION GPS COORDINATES OFFSET LUMINAIRE TYPE LED LAMP WATTAGE MAST ARM (FT) MOUNTING HGT. (FT) STANDARD PLAN # 10 1 10+76 27.64 CYCLONE , LED 80 10, 35.5' 117.1 02 1 11+17 33.36 CYCLONE , LED 80 10, 35.5' 117.1 03 1 11+35 74.96 CYCLONE , LED 80 10, 35.5' 117.1 40 1 11+81 66.43 CYCLONE , LED 80 10, 35.5' 117.1 05 1 11+87 83.31 CYCLONE , LED 80 10, 35.5' 117.1 06 1 13+32 -20.75 CYCLONE , LED 80 10, 35.5' 117.1 07 1 12+32 -20.30 CYCLONE , LED 80 10, 35.5' 117.1 0 1 11+86 -45.09 CYCLONE , LED 80 10, 35.5' 117.1 0 1 11+37 -56.37 CYCLONE , LED 80 10, 35.5' 117.1 1 11+21 -28.93 CYCLONE , LED 80 10, 35.5' 117.1 0 1 11+90 -26.67 CYCLONE , LED 80 10, 35.5' 117.1 WIRING SCHEDULE CONDUIT RUN CONDUIT SIZE CONDUCTORS NOTES Al 2" PVC 2 - #8,1 - #8 2� 2" PVC 4 - #8,1 - #8 33 2" PVC 6 - #8,1 - #8 REVISION SURVEYED: DESIGNED: LM DRAWN: LM CHECKED: JM APPROVED: A SCALE: 1 "=30' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY acl is AN NY5 COMPANY 19201 120th Ave NE, Suite 201 Bothell, WA 98011 425-951-4800 www.NV5.com VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M T-422808 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING �, TRANSPORTATION OPERATION Michael Sippo 11 /04/2022 .r CBarnes 11 /09/2022 ' + CITY OF RENTON ROUNDABOUT Planning/Building/Public Works Dept. SWA2 AMAZON CITY OF RENTON -SW 16TH ST/RAYMOND AVE SW LIGHTING PLAN DATE: 0-24-2022 FIEL PAGE: C7.0.1 SHEET: 1 OF:3 6 M O O N N A, u C'7 C'7 O O O T N Q J ^ 'T L J N O O O N N rr n z 0 N Q Q