LEGEND
® ELECTRICAL SERVICE CABINET
in PULL BOX TYPE 2
- - CONDUIT
OLUMINAIRE SCHEDULE NOTE
0 WIRING SCHEDULE NOTE
LED ROADWAY LUMINAIRE
AND DECORATIVE POLE
EXISTING LED ROADWAY LUMINAIRE
AND DECORATIVE POLE
NO.
GENERAL NOTES
1.
ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE WSDOT/APWA STANDARD PLANS,
STANDARD SPECIFICATIONS, LATEST AMENDMENTS TO THE STANDARD SPECIFICATIONS, CITY OF
RENTON STANDARD DETAILS, SPECIAL PROVISIONS, AND THESE PLANS.
2.
UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR
RESOLUTION.
3.
CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE ELECTRICAL SERVICE
CONNECTION. CONTRACTOR SHALL CONTACT THE PSE REPRESENTATIVE AT 1-888-321-7779 PRIOR
TO INSTALLATION OF METER BASE.
4.
FOR SIGNAL & ILLUMINATION SYSTEMS COORDINATION WITH THE CITY OF RENTON, CONTRACTOR
SHALL CONTACT TRANSPORTATION MAINTENANCE DEPARTMENT REPRESENTATIVE ERIC
CUTSHALL AT (425) 430-7423.
5.
THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR ARE FOR GRAPHICAL
PRESENTATION ONLY. FINAL LOCATIONS SHALL BE VERIFIED BY THE ENGINEER IN THE FIELD PRIOR
TO INSTALLATION.
6.
ALL NEW FOUNDATION LOCATIONS SHALL BE APPROVED BY THE ENGINEER PRIOR TO EXCAVATION.
7.
ALL NEW JUNCTION BOXES SHALL HAVE SKID RESISTANT LIDS AND FRAMES.
8.
ALL LUMINAIRE WIRING AND CONDUIT BETWEEN POLE AND JUNCTION BOX SHALL BE INSTALLED
PER CITY OF RENTON STANDARD PLAN 119.
9.
ALL NEW CONDUIT SHALL BE INSTALLED IN CITY OF RENTON RIGHT-OF-WAY.
10.
EXISTING SIGNAL AND LIGHTING CONDUIT MAY HAVE LESS THAN 121, OF COVER. CONTRACTOR
SHALL USE CAUTION WHEN EXCAVATING NEAR EXISTING CONDUIT.
11.
FOR ADDITIONAL GENERAL NOTES SEE CITY OF RENTON STANDARD PLAN 135.
12.
FOUNDATION DESIGN FOR LIGHT POLES REQUIRE GEOTECHNICAL ANALYSIS TO DETERMINE DEPTH
OF FOUNDATION PER CITY STD DETAIL 117.1A
CONSTRUCTION NOTES
1.
INSTALL STANDARD EEL LIGHT PER STANDARD PLAN C.O.R STANDARD PLAN 117.1
2.
INSTALL GHT STANDARD FOUNDATION PER STANDARD PLAN C.O.R STANDARD PLAN
AA
Poles are aluminum 3.
INSTALL ELECTRICAL SERVICE CABINET PER C.O.R STANDARD PLAN 122.1 AND 122.2 AT
APPROXIMATE STATION11+91, 35.24. COORDINATE WITH PSE FOR SERVICE CONNECTION. LABEL
BACK OF CONTRACTOR CABINET WITH ADDRESS LOCATION, USE 1" LETTERS
4.
INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD
LUMINAIRE #
POLE ID #
CIRCUIT #
STATION
GPS COORDINATES
OFFSET
LUMINAIRE TYPE
LED LAMP
WATTAGE
MAST ARM
(FT)
MOUNTING
HGT. (FT)
STANDARD
PLAN #
10
1
10+76
27.64
CYCLONE , LED
80
10,
35.5'
117.1
02
1
11+17
33.36
CYCLONE , LED
80
10,
35.5'
117.1
03
1
11+35
74.96
CYCLONE , LED
80
10,
35.5'
117.1
40
1
11+81
66.43
CYCLONE , LED
80
10,
35.5'
117.1
05
1
11+87
83.31
CYCLONE , LED
80
10,
35.5'
117.1
06
1
13+32
-20.75
CYCLONE , LED
80
10,
35.5'
117.1
07
1
12+32
-20.30
CYCLONE , LED
80
10,
35.5'
117.1
0
1
11+86
-45.09
CYCLONE , LED
80
10,
35.5'
117.1
0
1
11+37
-56.37
CYCLONE , LED
80
10,
35.5'
117.1
1
11+21
-28.93
CYCLONE , LED
80
10,
35.5'
117.1
0
1
11+90
-26.67
CYCLONE , LED
80
10,
35.5'
117.1
WIRING SCHEDULE
CONDUIT
RUN
CONDUIT
SIZE
CONDUCTORS
NOTES
Al
2" PVC
2 - #8,1 - #8
2�
2" PVC
4 - #8,1 - #8
33
2" PVC
6 - #8,1 - #8
REVISION
SURVEYED:
DESIGNED:
LM
DRAWN:
LM
CHECKED:
JM
APPROVED:
A
SCALE:
1 "=30'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
acl is
AN NY5
COMPANY
19201 120th Ave NE, Suite 201
Bothell, WA 98011
425-951-4800 www.NV5.com
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
T-422808
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING �, TRANSPORTATION OPERATION
Michael Sippo 11 /04/2022 .r CBarnes 11 /09/2022 ' +
CITY OF
RENTON
ROUNDABOUT
Planning/Building/Public Works Dept.
SWA2 AMAZON
CITY OF RENTON
-SW 16TH ST/RAYMOND AVE SW
LIGHTING PLAN
DATE: 0-24-2022
FIEL
PAGE:
C7.0.1
SHEET: 1 OF:3 6