Loading...
HomeMy WebLinkAboutT-42281000 N N z 0 N Q Q N Q cco 0) 3 zT a� 0 CP J 01 J / Q U L/L ry / 00 0 N O N / O N O N U N O L n / U O to N U •L U) N L 0 I LL N L.� z O N C O Q / E O U Ln / / Q z W J I GENERAL NOTES: 1. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN PASTS). 2. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL (GRADE ONCE CONSTRUCTION IS COMPLETE, 3. ALL EXISTING OR' PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL. MEET CURRENT ALGA STANDARDS(I.E. JUNCTION BOXES SHALL HAVE NON—SKID LICKS). 4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CQNNECT10N TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK. 5. ALL TRANSPORTATION ASSETS THAT ARE TO BE REMOVED AND THEN REINSTALLED AT A LAILl,, DATE DURING CONSTRUCTION SHALL BE RE -INSTALLED TO CURRENT STANDARDS. 6. SIGNAL POLE, LUMINAIRE AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 7- ALL PROPOSED SIGNAL POLE FOUNDAT104S AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD .AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAC'. FOUNDATION PAD SHALL BE AT LEA'_ 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS. B. 0EN THE TRAFFIC SIGNAL IS OPERATIONAL, 'VEHICLE DETECTION SHALL BE MAINTAINED AND REMAIN FUNCTIONAL, NEW PERMANENT/TEMPORARY VIDEO DETECTIO4%i SHALL BE INSTALLED AND OPERAT10NAL PRIOR TO DESTROYING ANY EXISTING VEHICLE DETECTION. 9. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS. OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION NTH THE TRANSPORTATION OPERAT1 NS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE. STD. PL4N - 135 GAZ 1 3/13/20.19 1 o 3 oJ-VA �, o LABEL THE STREET FACING SIDE OF THE CABINET ELEVATIONSECTION O WITH ADDRESS NUMBER (W/O STREET NAME) USING o b AN ENGRAVED PHENOLIC NAMEPLATE WITH 2" HIGH CD BLACK LETTERING ON WHITE BACKGROUND. ATTACH o y NAMEPLATE WITH ADHESIVE 0 n THE METER DOOR SHALL BE REMOVABLE. UNLESS SPECIFIED IN THE PLANS, THE `° DO 3 x METER DOOR HINGE SHALL BE LOCATED 12" ON LEFT SIDE OF THE CABINET 0) A _ D W w 72" D m o I 0 2 a ® 40„ m WIRING SCHEMATIC 00 :3 0 Z m METER PHOTO BASE CELL MAIN CONTROL TEST SERVICE SWITCH 16" 161, WIREWAY LTG. DEADFRONT m Z7 ="xJ 70 p C 8" 8.. 4" 13" GROUND 16.• g . FAULT o Ntj "d RECEPT. 8" _ � n z 2" TYP. 1 FOOTPRINT 00 o N 120/24OV, SINGLE PHASE, 3 WIRE 0 NOTES PER STANDARD PLAN 122.2 w " Docufgn EwWW* ICT; F41 ?V-1A8$AWE 62FC,224FAFW POLE & BRACKET CABLE. #12 AW. SPLICES BETWEEN EASE HOLDER AND LUMINAIRE FIXTURE SHALL NOT BE ALLOWED FUSE KITS QUICK AMR TO W�SDDT LOCKING QISC(7ldI+IECT 3 AMP IN LINE LID STANDARD DUTY FUSE KITS S.E.C. 4R EQUAL JUNCTION BOAC TYPES 1 & 2 $TWARO PLA4 JI-40.1i GROUND LUG SPLICE IKITS CLEAR EPDXY SPLICE KITS ON ALL THRU WIRE RUNS CONORETE PAD OR SIDEWALK PER STD PLAN 120 2e(MIN) COVER 0S RARE COPPED GROUND WIDE [MOUNDCLAMP 1 - EQUIPMENT GROUND i,+C C NNDLJI r2p WREW/GREEN INSULATION FROM SERVICE CABINET 2 - LIGHTING SYSTEM 0 xB' CODER GLAD MIRES TO CONTACTOR GROUND R€JQ (SIZED AS REQ'D-) 4 LUMINAIRE GREEN INSUILATEI) WRE TO FIXTURE GROUND LUG CONCRETE FCUNCATION NOTES:- 1. THIS DETAIL DEPICTS. THE BASIC LLUMIRAIRE ELECTRICAL WIRING SYSTEM. ADDITIONAL ELECTRICAL EQUIPMENT MAY VARY. 2, MINIMUM GROUND WIRE SIZE SHALL BE #$, AS SHOWN ADOVE. IF 'CURRENT CARRYING CONDUCTORS ARE LARGER THAN Y8, THE MINIMUM GROUND HIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDLUCTORS, 3. EUJIPMENT GROUND WRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE MOUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE- T.. IF THE FIXTURE MANUFACTURER HAS MADE PROMSI0N5 FOR THE ATTACHMENT OF A GROUND WIRE, Jai GREEN INSULATED WRE OF THE SAFE SIZE SHALL RUN FROM THE FIXTURE To THE GROUND LUG INSIDE THE POLE H.ANDHOLE. IF THE FIXTURE MANUFACTURER HAS A GROUND LUG A #B GREEN INSULATED VARE SHALL BE RUN FROM THE FIXTURE GROUND LUG TO THE RCLE 'GROUND LUG. LUMINAIRE ELECTRICAL STD. PLAN - 119 PTJBLIC WORK$ WIRING SYSTEM I' F DEPARTMENT Pr S/22/2019 REVISION SURVEYED: DESIGNED: M DRAWN: LM CHECKED: JM BY DATE AP P R APPROVED: JM SCALE: 1 "=30' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY rCkw40grn Emrebpo 10; SD308AIA-204p40E8,Ma4A2'H3.+HH';I 'eF c�a LUWINrURE POLE JJNCTICH Bblt a� CONCRETE PAD PLAN MEW —LUWINAJRE POLE l-fCOKRETE PAD - 4- JUNCTION € OX �LUMNAIRE CONCRETE POUNDA.TION Sol VEW LUMINARE CONCRETE PAD DETAIL 1. LLIAPIWRE CONCRETE PAL) SHALL EE USED IN AREAS OUTSIDE T SIDETI'&K 2. CCHIr11TE CLAT3 FUR LUMINARE LCINCRUL PAD SHALL BE PER STD PLAN 135 3. TOP OF L.UMINAARE FOUND.sNN ELEVATION Sma BE LOCATED AT F7f}TT01611 CF LUMINAJRE CGKRETE PAT( ELE0110H OR BOTTOM OE sibimv ELEYAT1 N d. LLMINARE POLE AND JJNCTICN BDX T1PE PER PLAN 5. LL"N.AIRE C.CNCRETE PAD AC.CCUMODATES TYPE 1 AND IYPL 2 JJNCTIGN BDRES ONLY o-r y ti. r� r L\- JLIIJc110H 1�4M C1CNCRETE 9EEWALK PLAN ti1E'N PER 517D PLAN 102 ---LUWINAJRE POLE URCRFTE SIDEWALK PER SrD PLAN 102 } JLv'TMr.Ti BOX ONCR E FWND.A.TION 9DE MEW LIlMINAI'RE WrTH SIDEWALK DETAIL OMCROTO PAD al1N4nON Box PL.e,' CDTF:RETE U'A] J T I JJNCTICN 8Dx 51DE MEN INDI1 QUAIL JUNCTION BOX PAD DETAIL LUMINAIRE CONCRETE STD. PLAN 1`20 * PUBLIC WGRKS PADISID'E1MIfALK AND �Tr_.D DEPARTMENT JUNCTION BOX CONCRETE PAD Gregg A, ZIImfTT1�}}��{�1 �fl�ar�_B 1 WHpaciflic AN NY5 COMPANY 19201 120th Ave NE, Suite 201 Bothell, WA 98011 425-951-4800 www.NV5.com VERTICAL: NAVD 1988 • HORIZONTAL: NAD 1983/1991 CITY OF RENTON [;R vuOr DATU M Planning/Building/Public Works Dept. T-42281 0 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING % � IL TRANSPORTATION OPERATION I Michael Sippo 11 /04/2022 CBarnes 11 /09/2022 SWA2 AMAZON CITY OF RENTON ROUNDABOUT -SW 16TH ST/RAYMOND AVE SW LIGHTING DETAILS DATE: 0o- 4-2022 FIELDB PAGE: C7.2.1 SHEET: OF: 33 36 LO O N A, U C'7 N O O T N Q J ^ 'T L J N O O N / N� rr n z 0 N Q Q N V 1