Loading...
HomeMy WebLinkAboutT-423113co CV O ry H Z O N Q Q N Q W M N N 00 U Q) c C 0 U L a� c rn to > Q J / to i 0 Q U L� ry / 00 0 N O N O N O N U N O L n Q z w J li DocuSign Envelope ID: 9D9I30DA8-0385-4664-AE66-57BFF1561 D7F POLE w 2'- o' _ z POLE 10'-0" (LUMINAIRE ARM = 3.5" DIA �n (LUMINAIRE ARM LENGTH) HOLE 2" TANGENT 2.5' R z F �_ s LLj _ 6'-0" 12'-0" (LUMINAIRE ARM LENGTH) DIRECT ACCESS TO THE SCREWS BRACKET LEADS THIS SIDE WIREWAY 5/8" ROADWAY SCALE 44" PEDESTRIAN SCALE TOP VIEW TERMINAL BLOCK CONNECTOR s� Y TERMINAL BLOCK HOUSING DETAIL jr[ VVII\LVV11I JI UILL UL IVIIIVMUM I IV, niNU IVI 11AHVIUM 1 I/2' OD. TYPICAL FOR ALL ARMS 'n (LUMINAIRE ARM LENGTH) o I 16' R 22" ROUND CAP o O w ALUMINUM SHROUD PIGTAIL FROM (BY MANUFACTURER) FIXTURE TO 4" OD HOLE TERMINAL BLOCK MANUFACTURER SHALL BE PROVIDED SHALL WELD SHROUD BY MANUFACTURER ALL THE WAY 31 I— AROUND FOR TERMINAL BLOCK DETAIL, SEE = THIS SHEET 8,-0„ (LUMINAIRE ARM LENGTH) 1 30' R 30" 4" OD HOLE LUMINAIRE ARM DETAILS LUMINAIRE ARM-IJ, LUMINAIRE U w CONDUCTORS, o CLAMP -ON TO LUMINAIRE SEE STD z DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS, PLAN 119 E TYPE 3 IES DISTRIBUTION, 4000K CCT, 120-277V 1i UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT GLASS LENS) BY CYCLONE (OR APPROVED EQUAL) DRIVER SHALL BE INTEGRAL TO THE FIXTURE LUMINAIRE ARM MOUNTING BRACKET NOTES: DETAILS 1. STD PLAN 117.1/117.1A ROADWAY SCALE LUMINAIRE ARM LENGTH SHALL BE 10' OR LESS 2. STD PLAN 117.1/117.1A PEDESTRIAN SCALE LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS 3. STD PLAN 117.2 LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS FOR ARTERIAL LOCATIONS, AND 2' FOR DOWNTOWN LOCATIONS 4. TYPE III TRAFFIC SIGNAL POLE LUMINAIRE ARM LENGTH SHALL BE 12' OR LESS 5. POLE AND BRACKET CABLE SHALL BE 10 AWG WITH O.D. LESS THAN 0.5 INCHES C��Y o� LUMINAIRE AND MOUNTING STD. PLAN- 117.3 PUBLIC WORKS BRACKET DETAIL DEPARTMENT 1�PDPROVED: 7/27/2022 1 5: Z Martin Pastucha F N DATE \l01 REVISION i I� kjmjm: SURVEYED: DESIGNED: AK DRAWN: AK CHECKED: JMK APPROVED: JMK SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFFi 1561D71F vi �� aCKET CABLE, #10 vt_L_ w AWG. SPLICES BETWEEN FUSE HOLDER AND LUMINAIRE FIXTURE SHALL NOT BE ALLOWED FUSE KITS QUICK DISCONNECT 3 AMP IN LINE FUSE KITS S.E.C. OR EQUAL, ONE PER CURRENT CARRYING REFER TO WSDOT LOCKING CONDUCTOR. APPLIES TO LUMINAIRE LID STANDARD DUTY AND RECEPTACLE WIRING JUNCTION BOX TYPES 1 & 2 STANDARD PLAN J-40.10 SPLICE KITS CLEAR EPDXY SPLICE GROUND LUG KITS ON ALL THRU WIRE RUNS CONCRETE PAD OR SIDEWALK PER STD PLAN 120 24"(MIN) COVER #8 BARE COPPER GROUND WIRE 1 - EQUIPMENT GROUND - WIRE W/GREEN INSULATION FROM SERVICE CABINET, SEE NOTE 2, THIS SHEET 2 - LIGHTING SYSTEM - WIRES TO CONTACTOR (SIZED AS REQ'D.) 2 - 120VAC RECEPTACLE SYSTEM WIRES TO SERVICE CABINET, IF APPLICABLE (SIZED AS REQ'D.) NOTES: TO LUMINAIRE /TO RECEPTACLE 120VAC RECEPTACLE WIRING, IF APPLICABLE. WIRING SIZE PER CONTRACT TO LUMINAIRE -GREEN INSULATED WIRE, SIZED TO MATCH THE LARGEST CURRENT CARRYING CONDUCTOR TERMINATE AT LUMINAIRE GROUND LUG -W� ������� II '�FER GROUND, GROUND II II NON -INSULATED #4 AWG CLAMP II II STRANDED COPPER, II PROVIDE 3' MIN. SLACK. 2" PVC CONDUIT II II ROUTE FROM GROUNDING LL= Iii LUG TO FOUNDATION REBAR. CONNECT TO REBAR USING AN ACORN 5/8"x8' COPPER CLAD CLAMP GROUND ROD CONCRETE FOUNDATION 1. THIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM. ADDITIONAL ELECTRICAL EQUIPMENT MAY VARY. 2. MINIMUM GROUND WIRE SIZE SHALL BE #8, AS SHOWN ABOVE. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN #8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS. 3. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 4. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN INSULATED WIRE, SIZED TO MATCH THE LARGEST CURRENT CARRYING CONDUCTORS, SHALL BE RUN FROM THE FIXTURE TO THE POLE GROUND LUG. 5. ALL CONDUIT SHALL BE PVC SCHEDULE 80. *N1 LUMINAIRE ELECTRICAL STD. PLAN - 119 PUBLIC WORKS WIRING SYSTEM APPROVED: DEPARTMENT Da°ss°°^°y 712712022 1 Martin Pastucha 989�3tGD060n�DD. DATE acl is ANN V5 COMPANY 19201 120th Ave NE, Suite 201 Bothell, WA 98011 425-951-4800 www.NV5.com VERTICAL: NAVD 1988 • HORIZONTAL: NAD 1983/1991 CITY OF RENTON DATUM • Planning/Building/Public Works Dept. T-423113 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING TRANSPORTATION OPERATION F Michael Sippo 11 /04/2022 ' cbarnes 11 /09/2022 IL SWA2 AMAZON CITY OF RENTON DETAILS LIND AVE SW AND SW 19TH STREET DATE: 10-24-202 FIELDBOOK: PAGE: SHEET. 13 OF: z O N Q 75 Q N Q U) H It N Q J ti co LO O N N LN