DocuSign Envelope ID: 9D9I30DA8-0385-4664-AE66-57BFF1561 D7F
POLE w
2'- o' _
z POLE 10'-0"
(LUMINAIRE ARM =
3.5" DIA �n (LUMINAIRE ARM LENGTH)
HOLE
2" TANGENT 2.5' R
z F
�_
s
LLj
_
6'-0"
12'-0"
(LUMINAIRE ARM LENGTH)
DIRECT ACCESS
TO THE SCREWS
BRACKET
LEADS
THIS SIDE
WIREWAY
5/8" ROADWAY SCALE
44" PEDESTRIAN SCALE
TOP VIEW
TERMINAL
BLOCK
CONNECTOR
s�
Y
TERMINAL BLOCK
HOUSING DETAIL
jr[
VVII\LVV11I JI UILL UL IVIIIVMUM I IV, niNU IVI 11AHVIUM 1 I/2' OD.
TYPICAL FOR ALL ARMS
'n
(LUMINAIRE ARM LENGTH)
o
I
16' R
22"
ROUND CAP
o
O
w
ALUMINUM SHROUD
PIGTAIL FROM
(BY MANUFACTURER)
FIXTURE TO
4" OD HOLE
TERMINAL BLOCK
MANUFACTURER
SHALL BE PROVIDED
SHALL WELD SHROUD
BY MANUFACTURER
ALL THE WAY
31
I—
AROUND
FOR TERMINAL
BLOCK DETAIL, SEE
=
THIS SHEET
8,-0„
(LUMINAIRE ARM LENGTH)
1 30' R 30"
4" OD HOLE
LUMINAIRE ARM DETAILS
LUMINAIRE ARM-IJ,
LUMINAIRE U w
CONDUCTORS, o
CLAMP -ON TO
LUMINAIRE
SEE STD z DOME STYLE LED LUMINAIRE (WATTAGE PER PLANS,
PLAN 119 E TYPE 3 IES DISTRIBUTION, 4000K CCT, 120-277V
1i UNIVERSAL DRIVER (750mA OR LOWER), WITH FLAT
GLASS LENS) BY CYCLONE (OR APPROVED EQUAL)
DRIVER SHALL BE INTEGRAL TO THE FIXTURE
LUMINAIRE ARM MOUNTING BRACKET
NOTES: DETAILS
1. STD PLAN 117.1/117.1A ROADWAY SCALE LUMINAIRE ARM LENGTH SHALL BE 10' OR LESS
2. STD PLAN 117.1/117.1A PEDESTRIAN SCALE LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS
3. STD PLAN 117.2 LUMINAIRE ARM LENGTH SHALL BE 4' OR LESS FOR ARTERIAL LOCATIONS, AND 2' FOR DOWNTOWN LOCATIONS
4. TYPE III TRAFFIC SIGNAL POLE LUMINAIRE ARM LENGTH SHALL BE 12' OR LESS
5. POLE AND BRACKET CABLE SHALL BE 10 AWG WITH O.D. LESS THAN 0.5 INCHES
C��Y o� LUMINAIRE AND MOUNTING STD. PLAN- 117.3
PUBLIC WORKS BRACKET DETAIL
DEPARTMENT 1�PDPROVED: 7/27/2022 1 5:
Z Martin Pastucha
F N DATE
\l01
REVISION
i I� kjmjm:
SURVEYED:
DESIGNED:
AK
DRAWN:
AK
CHECKED:
JMK
APPROVED:
JMK
SCALE:
1 "=20'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
DocuSign Envelope ID: 9D9BODA8-0385-4664-AE66-57BFFi 1561D71F vi �� aCKET CABLE, #10
vt_L_ w
AWG. SPLICES BETWEEN FUSE
HOLDER AND LUMINAIRE FIXTURE
SHALL NOT BE ALLOWED
FUSE KITS QUICK DISCONNECT 3 AMP
IN LINE FUSE KITS S.E.C. OR EQUAL,
ONE PER CURRENT CARRYING
REFER TO WSDOT LOCKING CONDUCTOR. APPLIES TO LUMINAIRE
LID STANDARD DUTY AND RECEPTACLE WIRING
JUNCTION BOX TYPES 1 &
2 STANDARD PLAN J-40.10
SPLICE KITS CLEAR EPDXY SPLICE GROUND LUG
KITS ON ALL THRU WIRE RUNS
CONCRETE PAD OR
SIDEWALK PER STD PLAN 120
24"(MIN) COVER #8 BARE COPPER
GROUND WIRE
1 - EQUIPMENT GROUND -
WIRE W/GREEN INSULATION
FROM SERVICE CABINET,
SEE NOTE 2, THIS SHEET
2 - LIGHTING SYSTEM -
WIRES TO CONTACTOR
(SIZED AS REQ'D.)
2 - 120VAC RECEPTACLE SYSTEM
WIRES TO SERVICE CABINET, IF
APPLICABLE (SIZED AS REQ'D.)
NOTES:
TO LUMINAIRE
/TO RECEPTACLE
120VAC RECEPTACLE WIRING, IF
APPLICABLE. WIRING SIZE PER
CONTRACT
TO LUMINAIRE
-GREEN INSULATED WIRE, SIZED
TO MATCH THE LARGEST
CURRENT CARRYING CONDUCTOR
TERMINATE AT LUMINAIRE
GROUND LUG
-W� ������� II '�FER GROUND,
GROUND II II NON -INSULATED #4 AWG
CLAMP II II STRANDED COPPER,
II PROVIDE 3' MIN. SLACK.
2" PVC CONDUIT II II ROUTE FROM GROUNDING
LL= Iii LUG TO FOUNDATION
REBAR. CONNECT TO
REBAR USING AN ACORN
5/8"x8' COPPER CLAD CLAMP
GROUND ROD CONCRETE FOUNDATION
1. THIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING SYSTEM. ADDITIONAL ELECTRICAL EQUIPMENT MAY VARY.
2. MINIMUM GROUND WIRE SIZE SHALL BE #8, AS SHOWN ABOVE. IF CURRENT CARRYING CONDUCTORS ARE LARGER THAN
#8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST WIRE SIZE OF THE CURRENT CARRYING CONDUCTORS.
3. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE
HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE.
4. IF THE FIXTURE MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF A GROUND WIRE, A GREEN INSULATED
WIRE, SIZED TO MATCH THE LARGEST CURRENT CARRYING CONDUCTORS, SHALL BE RUN FROM THE FIXTURE TO THE POLE
GROUND LUG.
5. ALL CONDUIT SHALL BE PVC SCHEDULE 80.
*N1
LUMINAIRE ELECTRICAL STD. PLAN - 119
PUBLIC WORKS WIRING SYSTEM
APPROVED:
DEPARTMENT Da°ss°°^°y 712712022 1
Martin Pastucha
989�3tGD060n�DD.
DATE
acl is
ANN V5 COMPANY
19201 120th Ave NE, Suite 201
Bothell, WA 98011
425-951-4800 www.NV5.com
VERTICAL: NAVD 1988 •
HORIZONTAL: NAD 1983/1991 CITY OF
RENTON
DATUM •
Planning/Building/Public Works Dept.
T-423113
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING TRANSPORTATION OPERATION
F
Michael Sippo 11 /04/2022 ' cbarnes 11 /09/2022 IL
SWA2 AMAZON
CITY OF RENTON
DETAILS
LIND AVE SW AND SW 19TH STREET
DATE:
10-24-202
FIELDBOOK:
PAGE: