Loading...
HomeMy WebLinkAboutR-420014W Z 0 0 N CB #6 CB# 7 2 BOTTOM OF FLOW CONTROL STRUCTURE C5.10 3-FOOT TANK: 25.6925.50 ' DESIGN WATER 0 SURFACE EL: 28.19 0.50' FREEBOARD Lij PROPOSED GRADE AT CB# 8 STORM CENTERLINE EXISTING GRADE AT STORM CENTERLINE 35 3 MP - - - - - ----- - ----- 1ZnF-36"CMF- ----------- - - --------------------- - ------------------------------------------------ ----------------- -----j ------ -- - -- ------------------------------------------------------------------------------------ 25 - - - - _ - - -17 0.50'DEAD STORJ77 I I I PROPOSED STORM GENTER z 20 M rn co O Lij O o O G ' co '� M w LOL w ILL.w ILL. rr Q 0+50 n Q STORM PROFILE 0 NOT TO SCALE iw rr w FRAME AND LADDER OR STEPS OFFSET. SEE NOTE 6. d Q 1'-6" MIN. ° IE: 25.38 (36" CMP) Ln 0o O M '� co U Q w 1+00 Iid d 0.5' �Z_ MAX. W.S. =28.19 nrnTANG ii ARVVEIR _ T7E)T-TE)n n ri . 2:7 62 2.0' LIVE STORAGE 3 S I 1 EAR A T E 0.5' DEAD STORAGE a 2.0' MIN Q 2.0' MIN I CB# 9 52 LF 36" CMP 4 ACCESS RISER (TYP.) C5.10 CB# 11 3.21, ----------------------4------------------ PROPOSED WATER MAIN CB# 14 O Lo Ln CO Ln 17 O CD co 17 Lr)� r O O Ln O N O p O O� O L O r O_ O O N O M O O O 00 O N O N O O N O O N O N _' M Cl) M t� N co t� N co N N co N M N N M N N co n N co N N M N M N N M n M N M N� M N co N co UO 00 00 0(D 00 00 U(D U(D (D UO UO 00 UL OL w LL. w LL. Lid LL. Ld LL w LL w LL w LL. Lid LL. w LL. w LL. w LL w LL w LLLL W LL. W L LCJ L 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 ROUND SOLID COVER, WITH INVERTED FRAME MARKED "DRAIN" WITH LOCKING BOLTS. 8" INLET a a FRAME AND LADDER OR STEPS OFFSET. SEE NOTE 6 2' MIN. CLEARANCE TO - ANY PORTION OF VERTICAL RISER, ELBOWS, OR SHEAR GATE - 2.5" a d � 54" TYPE 2 CATCH BASIN CONTROL �STRUCTURE 2 NOT TO SCALE ®R Know what's below. Call before you dig. TOP OF 1TA� RECORD NOTE 03/26/2024 SgINC� tS' THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON INFORMATION SUBMITTED, IN PART, BY OTHERS. THOSE flFt 4 RELYING ON THIS RECORD DOCUMENT ARE 46416 0 :'R ISTERE9 ADVISED TO OBTAIN INDEPENDENT 10 AL EVERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. w SEE DRAINAGE CONTROL PLAN FOR RIM ELEVATIONS O 00 LU ° M O s U 36" INLET 36" O CMP COUPLING BAND NOTES: 1. PIPE SLOP S PER PLANS. 2 PIPE SUP ORTS AND RESTRICTOR SHALL BE OF SAME OUTLET MATERIA AND BE ANCHORED AT 3' MAX. SPACING BY IE: 26.19 12" CPE 5/8" DIA. S AINLESS STEEL EXPANSION BOLTS OR EMBEDD 2" IN WALL. (SUPPORT BRACKETS SHALL BE 3" x 0.09( AGE) RISER STRUCTURE NOT 3. THE RES ICTOR SHALL BE FABRICATED FROM .060" INSTALLED ALUMINU , OR .064" ALUMINIZED STEEL, OR .064" COUPLING BAND GALVANI D STEEL PIPE; IN ACCORDANCE WITH AASHTO 36, M 196, M 197 AND M 274. GALVANIZED STEEL SH LL HAVE TREATMENT I. 4. OUTLET ALL BE CONNECTED TO CULVERT OR SEWER PI E WITH A STANDARD COUPLING BAND FOR CORRUGA ED METAL PIPE, OR GROUTED INTO THE BELL OF NCRETE PIPE. 5. THE VERT AL RISER STEM OF THE RESTRICTOR / ELEV. �9- SEPARAT R SHALL BE 18" MIN. DIA. = WELDED PLATE WITH 6. FRAME AN LADDER OR STEPS OFFSET SO THAT: ORIFICE 0 = 2 L" A. CLEA OUT GATE IS VISIBLE FROM TOP. B. CLIMB DOWN SPACE IS CLEAR OF RISER AND CLEA OUT GATE. C. FRA IS CLEAR OF CURB. 7. IF METAL UTLET PIPE CONNECTS TO CEMENT CONCRET PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO ONCRETE PIPE I.D. LESS 1/4". 8. MULTI -OR ICE ELBOWS MAY BE LOCATED AS SHOWN OR ALL ON ONE SIDE OF RISER TO ASSURE LADDER CLEARAN E. 9. ALL META PARTS SHALL BE CORROSION RESISTANT. Civil Engineers 001 1 ShucN�alEngineers 002 - a�e�geA,hilele CommuniyF�anners 003 004 Q O nayors � Neighbors Wghb 005 T A C O M A • S E A T T L E N 0 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422 TEL 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 206.267.2425 TEL ASI-001 PROGRESSIVE CONSTRUCTION SET UPDATES PER CONDITIONS OF APPROVAL GRADY WAY STORMWATER REVISIONS AS -BUILT REVISIONS REVISION STANDARD LOCKING MH. FRAME & LID STANDARD MANHOLE STEPS @ 12" O.C. (TYP.) GRAVEL BACKFILL FOR PIPE ZONE BEDDING PER W.S.D.O.T. 9-03.12(3), 95% COMPACTION. IF SUBGRADE DOES NOT MEET ° COMPACTION REQUIREMENTS FOR SUPPORT OF THE UTILITY, OVER z ° EXCAVATE TO PROVIDE A MINIMUM OF CID 2° 12-INCHES OF QUARRY SPALLS PLACED _ -I _ _ ° OVER A GEOTEXTILE SUCH AS MIRAFI I- �I� III 1I1 1 50OX OR EQUIVALENT APPROVED BY THE -III-III-III= -III-III-IIIII-III=1 I I -I I I GEOTECHNICAL ENGINEER. SECTION OF FLOW CONTROL TANK HANDLE WITH �� � LOCK PIN. SIX EVENLY SPACED HOLES ON 10 3/8" BOLT CIRCLE FOR BOLTING TO FLANGE CONNECTION. O .�7 TO MAXIMUM OPENING OF GATE ADJUSTABLE LOCK HOOK WITH LOCK SCREW. 1" ROD OR TUBING, VARIABLE LENGTH. Lit t it-mmuLE SHALL BE ATTACHED TO SHEAR GATE. LIFT HANDLE SIDE NOTES: 1. SHEAR GATE SHALL BE ALUMINUM ALLOY PER ASTM B-26-ZG-32a 2. GATE SHALL BE 8" DIAM. UNLESS OTHERWISE SPECIFIED. 3. GATE SHALL BE JOINED TO TEE SECTION BY BOLTING (THROUGH FLANGE), WELDING, OR OTHER SECURE MEANS. 4. LIFT ROD: HANDLE EXTENDING TO WITHIN ONE FOOT OF COVER AND ADJUSTABLE HOOK LOCK FASTENED TO FRAME OR UPPER HANDHOLD. 5. GATE SHALL NOT OPEN BEYOND THE CLEAR OPENING BY LIMITED HINGE MOVEMENT, STOP TAB, OR SOME OTHER DEVICE. 6. NEOPRENE RUBBER GASKET REQUIRED BETWEEN RISER MOUNTING FLANGE AND GATE FLANGE. 7. MATING SURFACES OF LID AND BODY TO BE MACHINED FOR PROPER FIT. 8. FLANGE MOUNTING BOLTS SHALL BE 3/8" DIAM. STAINLESS STEEL. 9. ALTERNATE CLEANOUT/SHEAR GATES TO THE DESIGN SHOWN ARE ACCEPTABLE, PROVIDED THEY MEET THE MATERIAL SPECIFICATIONS ABOVE AND HAVE A SIX BOLT, 10 3/8" BOLT CIRCLE FOR BOLTING TO THE FLANGE CONNECTION. SHEAR GATE NOT TO SCALE CJ 9/27/221 DT SURVEYED: T.L. CJ 12/5/22 DT DESIGNED: J.N. DT 1/27/23 DT CW 12/26/23 TS DRAWN: J.N. AA 03/26/24 TS CHECKED: DT BY I DATE I APPR I APPROVED: SCAM PER SHEET HORIZONTAL NAD 1983/1991 CITY OF 1;R] RENTON ONE INCH DATU M AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY STANDARD 60" CONC TOP SLAB 36"( RISEN CONNECT TO BUILDING PLUMBING RECORD NOTE 03/26/2024 THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON SURVEY INFORMATION PROVIDED BY A THIRD -PARTY SURVEYOR. AHBL WILL BE RESPONSIBLE FOR THE DATA PROVIDED BY THEM. THE THIRD -PARTY SURVEYOR WILL BE RESPONSIBLE FOR THE ACCURACY OF THE ACTUAL LOCATIONS IN THE FIELD. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. FRAME LOCKING LID (MARKED "DRAIN") MOUNTED OVER 24" DIA ECCENTRIC OPENING DETENTION TANK PLAN VIEW MAINTAIN 1" GAP BETWEEN BOTTOM OF SLAB & TOP OF RISER - PROVIDE PLIABLE GASKET TO STANDARD LOCKING EXCLUDE DIRT MH. FRAME & COVER 36" RISER, 36" DIA. MIN., SAME STANDARD 60" CONCRETE MATERIAL & GAGE AS TOP SLAB TANK WELDED OR FUSED TO TANK COMPACTED PIPE DETENTION TANK BEDDING (TYP) 241"MAX. WELD OR BOLT_51 STANDARD MH. STEPS 12" O.C. NOTES: 1. USE ADJUSTING BLOCKS AS REQUIRED TO BRING FRAME TO GRADE. 2. ALL MATERIALS TO BE ALUMINUM OR GALVANIZED AND ASPHALT COATED (TREATMENT 1 OR BETTER). 3. MUST BE LOCATED FOR ACCESS BY MAINTENANCE VEHICLES. 4. THE MAXIMUM DEPTH FROM FINISHED GRADE TO TANK INVERT SHALL BE 20 FEET. 5. ACCESS OPENINGS SHALL BE POSITIONED A MAXIMUM OF 50 FEET FROM ANY LOCATION WITHIN THE TANK. 6. ALL TANK ACCESS OPENINGS SHALL HAVE ROUND, SOLID LOCKING LIDS WITH 5/8 INCH DIAMETER ALLEN HEAD CAP SCREWS. 7. THIRTY-SIX INCH MINIMUM DIAMETER CMP RISER -TYPE MANHOLES OF THE SAME GAGE AS THE TANK MATERIAL MAY BE USED FOR ACCESS ALONG THE LENGTH OF THE TANK. 8. THE TOP SLAB IS SEPARATED (1 INCH MINIMUM GAP) FROM THE TOP OF THE RISER TO ALLOW FOR DEFLECTIONS FROM VEHICLE LOADINGS WITHOUT DAMAGING TANK. 9. ALL TANK ACCESS OPENINGS MUST BE READILY ACCESSIBLE BY MAINTENANCE VEHICLES. 10. TANKS MUST COMPLY WITH THE OSHA CONFINED SPACE REQUIREMENTS, WHICH INCLUDES CLEARLY MARKING ENTRANCES TO CONFINED SPACE AREAS. THIS MAY BE ACCOMPLISHED BY HANGING A REMOVABLE SIGN IN THE ACCESS RISER(S), JUST UNDER THE ACCESS LID. rA'�\�A�CC�ES�S RISERS NOT TO SCALE U R-420014 I � IN COMPLIANCE WITH CITY OF RENTON STANDARDS 7 WATERSHED APARTMENTS CONSTRUCTION DRAFT SET FLOW CONTROL DETAILS Cw G rr Q a LU = DATE: 03/28/2023 FIELDBOOK: PAGE: LU � DRAWING NO: C5.10 `a SHEET: 14 A OF. 48 I 't