HomeMy WebLinkAboutR-420015W I— z Uj G I— rr Q n Lj r= V rr LLI I— 5�M z J 4-INCH SLOTTED PVC TC: 32.15' 36"X36" ACCESS HATCH 5'-0" 4'-0" INLET CONTOUR RACK WITH — PERFORATED FLOOR. 24" x 7" CURB INLET WITH 6" OVERHANG 7'-0" 6' 0" 6" TYPICAL WALL THICKNESS TOP SLAB NOT SHOWN IN THIS VIEW FOR CLARITY. -�o�+�-OZ 0 �o�o�o�o�o� �o�0 o�o—�0—o 0-0-0-0 1 COVERS SHOWN IN PHANTOM �0�0�0�0�0� �0� 00 00000000000 ° 0-0-0-0-0 0000000 18"X36" ACCESS HATCH 0-0-0-0-0-0-0- 0-0-0-0-0-0-0-0— 0-0-0-0-0-0-0-0— 0-0-0-0-0 0-0� o oro�"0oo J OUTLET CHAMBER 0�0�b 1-+— -0 0opo0o0o000000 opopo0o 00-0s�o� -0 0-0 —0-0 �0�0�0�0� �0�0-0-0-0-0-0°0 o� 00 �0�0 0�0�0�0�0�0�0 0 0° o 0 I 0-0-0-0-0-0 0-0- °o°o°o°o°o° o°o° 0 0 0-0 °o°oJII o°0. LINET FIELD POURED CURB FACE, BY OTHERS OUTLET, 010" OPENING FOR 08" CPEP, IE: 28.65' 2'-0" 2'-0" 2'-0" 4'-0" A4I A11-AI 24"x7" CURB INLET 36"X36" ACCESS HATCH INLET CONTOUR RACK WITH PERFORATED FLOOR OPENING TO BIOFILTRATION CHAMBER 18"X36" ACCESS HATCH BYPASS WEIR/OUTLET BAY 6" I T 7" TOP SLAB 2" MULCH [ 8 00"] 3 IO 18" StormMixT"^ ME Ip A 6" DRAINROCK EL: 28.15' 6" BASE SLAB 04" SLOTTED PVC UNDERDRAIN UNDERDRAIN ORIFICE CAP ELEVATION VIEW WQ #1 NOT TO SCALE OUTLET, 010" OPENING FOR 08" CPEP, NEARSIDE. 10" V-6" 24"x7" CURB INLET WITH 6" OVERHANG TC: 32.15' 3.50' [42.00"] IE: 28.65' OUTLET, 010" OPENING FOR 08" CPEP. III 11-1 I SURFACE SEAL; NATIVE SOIL OR -1 IIII I1—III- OTHER LOW PERMEABILITY MATERIAL. = 1=III =111=III=III=11I—III—III—III—III—III=11I GRAVEL BACKFILL FOR DRAINS; —I 11=111=1 11=1 1=1 1=1 1=1 1=1 1=1 1=1 „ WSDOT STANDARD SPECIFICATIONS, SECTION 9-03.12(4), FOUNDATION STRUCTURE PER FOUNDATION DETAILS DRAIN PIPE; PERFORATED OR SLOTTED RIGID PVC PIPE LAID WITH O PERFORATIONS OR SLOTS FACING 6" MINIMUM ���� DOWN; TIGHT JOINTED; WITH A DIAMETER ,' �' �' �' �' �' �' POSITIVE GRADIENT. DO NOT USE FLEXIBLE CORRUGATED PLASTIC PIPE. DO NOT TIE BUILDING DOWNSPOUT DRAINS INTO FOOTING LINE. 2" MIN 2" MIN. 4" MAX GEOTEXTILE FABRIC, PER WSDOT M22-01 CH. 630. FOUNDATION DESIGN PER 18" MIN. STRUCTURAL PLANS AND DETAILS FOUNDATION DRAIN NOT TO SCALE Know what's below. Call before you dig. 0511212022 UNIT ID WQ #1 BPS-461 B-S I Treatment Flow Rate 33.4 gpm / 0.074 cfs BYPASS WEIR/OUTLET BAY 18"X36" ACCESS HATCH II I II I II UNDERDRAIN ORIFICE CAP RIGHT END VIEW Bioretenfion/ Biofifiration NOTES: 1. DESIGN LOADINGS: A. 300 PSF PEDESTRIAN LOADING. B. ASSUMED WATER TABLE = S BELOW GRADE. C. DRY LATERAL EARTH PRESSURE (EFP) = 40 PCF. D. LATERAL LIVE LOAD SURCHARGE = 80 PSF (APPLIED TO 8' BELOW GRADE). E. NO LATERAL SURCHARGE FROM ADJACENT BUILDINGS, WALLS, PIERS, OR FOUNDATIONS. 2. CONCRETE 28 DAY COMPRESSIVE STRENGTH SHALL BE 5,000 PSI MINIMUM. 3. STEEL REINFORCEMENT: REBAR, ASTM A-615 OR A-706, GRADE 60. 4. MESH REINFORCEMENT: ASTM A-1064, S1.2, GRADE 80. 5. CEMENT: ASTM C-150 SPECIFICATION. 6. REFERENCE STANDARD: A. ASTM C 890 B. ASTM C 913 7. THIS STRUCTURE IS DESIGNED TO THE PARAMETERS NOTED HEREIN. PLEASE VERIFY THAT THESE PARAMETERS MEET PROJECT REQUIREMENTS (I.E. LIVE LOAD, FILL RANGE, WATER TABLE). IF DESIGN PARAMETERS ARE INCORRECT, REVIEWING ENGINEER/AUTHORITY SHALL NOTIFY OLDCASTLE INFRASTRUCTURE UPON REVIEW OF THIS SUBMITTAL, 8. OVERSIZED HOLES TO ACCOMMODATE SPECIFIC PIPE TYPE MUST BE CONCENTRIC TO PIPE ID. AFTER PIPES ARE INSTALLED, ALL ANNULAR SPACES SHALL BE FILLED WITH A MINIMUM OF 3000 PSI CONCRETE FOR FULL THICKNESS OF PRECAST WALLS. PIPES ARE TO BE FLUSH WITH THE INSIDE SURFACE OF THE CONCRETE STRUCTURE. 9. CONTRACTOR RESPONSIBLE TO VERIFY ALL SIZES, LOCATIONS AND ELEVATIONS OF OPENINGS. 10. CONTRACTOR RESPONSIBLE TO ENSURE ADEQUATE BEARING SURFACE IS PROVIDED (I.E. COMPACTED AND LEVEL PER PROJECT SPECIFICATIONS). 11. ADAPTORS/ANGLES AND EXTERNAL PIPING BY OTHERS. 12. MAXIMUM PICK WEIGHT: BASE CHARGED WITH ROCK & MEDIA= 13,500 LBS. RIGID FLEXIBLE (DI, CONC) (CPEP, CMP, PVC) UTILITY TRENCH BACKFILL SHALL BE BANKRUN GRAVEL PER WSDOT 9-03.19, \\,\\� \\� COMPACTED TO 95% (MIN). SUITABLE SUBGRADE ELEVATION NATIVE STRUCTURAL FILL MAY BE USED FOR TRENCH BACKFILL IF COMPACTION \\ \� \� j\� \N CAN BE ACHIEVED AS APPROVED BY THE GEOTECHNICAL ENGINEER GRAVEL BACKFILL FOR PIPE ZONE BEDDING PER W.S.D.O.T. \\ 9-03.12(3), 95% COMPACTION. 0 0 O o �n 0 6" MIN IF SUBGRADE DOES NOT MEET COMPACTION REQUIREMENTS \ \ \ FOR SUPPORT OF THE UTILITY, OVER EXCAVATE TO PROVIDE A MINIMUM OF 12-INCHES OF QUARRY SPALLS PLACED OVER A PIPE AS SPECIFIED GEOTEXTILE SUCH AS MIRAFI 50OX OR EQUIVALENT APPROVED ON PLAN OR SPECS BY THE GEOTECHNICAL ENGINEER. TRENCH WIDTH PER WSDOT 2-09.4 PIPE TRENCHING NOT TO SCALE 1' — � O T A C O M A S E A T T L E 2215 North 30th Street, Suite 300, Tacoma, WA 98403 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 -ginees Stt Strucwal Eigineers LandscWArchitects Community Plannero Land Surve}rors Neighbors 253.383,2422 TEL 206.267.2425 TEL 1 PERMIT REVISION JN 2 PERMIT REVISION JN 3 PERMIT REVISION JN N 0. REVISION BY 3/ 18/22 DT SURVEYED: T.L. 4/25/22 DT DESIGNED: J.N. 5/12/22 DT DRAWN: J.N. CHECKED: DT DATE AP P R APPROVED: DRILL & TAP 5/" -11 NC HOLE FOR STAINLESS STEEL SOCKET HEAD CAP SCREW (TYP.) LETTERING: ("STORM") RAISE - 1/2" WIDE BORDER 1/2" 10" 91, 8-3/4" 2/2"1" -1/4+ 5/8" 41, � 1 1 I 4" ===F- L 7" 2-7/8" 7-3/4" 8" 15" CAST IRON RING AND COVER CLEANOUT NOT TO SCALE SCALE: PER SHEET ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY GRAVEL BACKFILL FOR DRAINS PER WSDOT 9-03.12(4) PERMEABLE GEOTEXTILE SEPARATION FABRIC NOTES: 1. PIPE MATERIAL AS SPECIFIED BY THE ENGINEER. 2. PIPE DIAMETER AS SHOWN PER PLAN. 3000 PSI CLASS C CONCRETE (TYP) N— 1'-6" { 6" 12" 0 FIBRE JC PACK 6" PERFORATED OR SLOTTED RIGID PVC PIPE 1 FRENCH DRAIN NOT TO SCALE 45- (1/8) BEP 18" PROVIDE CHERNEY PLUG -3/4" II I PLUG TO BE SEALED IN SAME MANNER AS MAIN STORM JOINTS 24" MIN Lf J LO T O O N LJ T a J R-420015 IU) IN COMPLIANCE WITH CITY OF RENTON STANDARDS z z LLJ DEVELOPMENT ENGINEERING SURFACE WATER UTILITY JChavez 05/17/2022 J Farah 05/17/2022 Q n DATE, Uj 0 WATERSHED APARTMENTS 03/ / 2 HORIZONTAL' � ,�7,N, ' CITY OF o3 1 s 2022 ^ RENTON CIVIL CONSTRUCTION PERMIT PAGE*FIELDOK: r/' PAGE I(r DATU M DRAWING NO: W Planning/Building/Public Works Dept. STORM DETAILS C5.20 Q SHEET: OF: 15 46