w
a
COURTYARD - LEVEL 2
1"=10'
NOTE:
CRITICAL ANALYSIS
1. COORDINATE WITH PLUMBER AND
ROOFER FOR WATER SUPPLY THROUGH
Generated:
ROOF
2. INSTALL ALL COMPONENTS INSIDE
P.O.C. NUMBER: 02
BENCH
Water Source Information
3. INSTALL HEAT TAPE ON COPPER AND
BRASS PIPE INSIDE BENCH
FLOW AVAILABLE
Point of Connection Size:
0
Flow Available:
PRESSURE AVAILABLE
Static Pressure at POC:
2021-09-28 16:58
COURTYARD LEVEL 2
3/4"
12.06 gpm
62.00 PSI
Pressure Available:
62.00 psi
DESIGN ANALYSIS
Maximum Station Flow:
2.95 gpm
Flow Available at POC:
12.06 qpm
Residual Flow Available:
9.11 gpm
Critical Station:
15
Design Pressure:
40.00 psi
Friction Loss:
0.04 psi
Fittings Loss:
0.00 psi
Elevation Loss:
0.00 psi
Loss through Valve:
1.34 psi
Pressure Req. at Critical Station:
41.39 psi
Loss for Fittings:
0.01 psi
Loss for Main Line:
0.06 psi
Loss for POC to Valve Elevation:
0.00 psi
Loss for Backflow:
5.50 psi
Critical Station Pressure at POC:
46.96 psi
Pressure Available:
62.00 psi
Residual Pressure Available:
15.04 psi
LEVEL 2 - BENCH IRRIGATION POC
1/4" = 1'-0"
- 19 T
1 II )c
6
1"
42'-11 "
PLANTER ON PEDESTAL 5
PAVERS 3.0
LEVEL 6 - IRRIGATION POC / 4
4
ROOF DECK GREEN SPACE -LEVEL 6
1"=10'
NOTE:
1. COORDINATE WITH PLUMBER AND ROOFER FOR
WATER SUPPLY THROUGH ROOF
0 2. INSTALL ALL COMPONENTS INSIDE BBQ CABINETS
3. INSTALL HEAT TAPE ON COPPER AND BRASS PIPE
INSIDE CABINET
CRITICAL ANALYSIS
Generated: 2021-09-28 17:13
_ P.O.C. NUMBER: 03
Water Source Information: 6TH FLOOR ROOF GARDEN
FLOW AVAILABLE
Point of Connection Size:
3/4"
Flow Available:
10.20 gpm
-
PRESSURE AVAILABLE
Static Pressure at POC:
42.00 PSI
Pressure Available:
42.00 psi
DESIGN ANALYSIS
Maximum Station Flow:
3.19 gpm
Flow Available at POC:
10.20 gpm
Residual Flow Available:
7.02 gpm
Critical Station:
19
Pressure Req. at Critical Station:
27.31 psi
Loss for Fittings:
0.01 psi
Loss for Main Line:
0.13 psi
Loss for POC to Valve Elevation:
0.00 psi
Loss for Backflow:
5.77 psi
Critical Station Pressure at POC:
33.22 psi
Pressure Available:
42.00 psi
Residual Pressure Available:
8.78 psi
LEVEL 6 - IRRIGATION POC
1/4" = 1'-0"
63'-8 1/4"
.,- BLDG, SEE ARCH.
1 " = V-0"
20'-9 1/4"
KEEP CONTAINERS LEVEL WITH
ADJACENT BLDG
HOLD SOIL 2" BELOW TOP OF
PLANTER
GEOTEXTILE FILTER FABRIC
PLANTER, SEE SPECS
1/2" IRRIGATION POLY FLEX PIPE
FOR REFERENCE ONLY -
UNDER SEPARATE PERMIT
R-420035
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING , ,
AMor nrioth 0511 T,2022 _
�. O r R. S J y/,1/ ■ CiWlEngin- SURVEYED: SCALE:
�o /f 1 PERMIT REVISION E.H. 3 18 22
O G�P` % 1 SW,1--Engineers / / T.L. HoR ONALLNADD19183/1991 WATERSHED APARTMENTS / /
2 PERMIT REVISION E.H. 4/25/22 PER SHEET CITY OF 03 18 2022
� �.ndxar�a�,rrecrs DESIGNED: � I
�° ��nm.niryP�n 3 PERMIT REVISION E.H. 5/12/22 M.S. RENTON CIVIL CONSTRUCTION PERMIT FIELD900K:
Q PAGE:
L.nds�nreynrs DRAWN:
�� 2� OtiM V ■ Negnao E.
H.
ONE INCH DRANnNG N0:
CHECKED: DATU M
Know what's below. �� , 'ExP.o31°�\���� \��� TA C O M A S E AT T L E C.T. AT FULL SCALE Plonning/Building/Public Works Dept. IRRIGATION PLAN LEVELS 2 AND 6 L3.1
IF NOT ONE INCH
S �. Yti 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422 TEL N O. REVISION BY DATE A P P R SCALE ACCORDINGLY
Call before you dig. eq P E A?, Oy\ 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 206.267.2425 TEL APPROVED: SHEET: 44 oF:46
L J
^ 'T
L J
T
N
I_ k
M
T
a
J
T
r
0-