Loading...
HomeMy WebLinkAboutR-420036V ) I- z 5w L rr a n Q n w rr W Q PVC MAINLINE. TYPICAL VALVE, FILTER, PRESSURE REGULATOR. TYPICAL OFFSET 2" FROM HARDSCAPE, 4" FROM PLANTED 15 AREA. TYPICAL OFFSET 2" FROM TYPICAL LATERAL HARDSCAPE, 4" FROM PIPE FROM VALVE PLANTED AREA. ASSEMBLY, SIZE I I I PER PLANS. III I PVC SUPPLY HEADER, SIZE ASS I PER HEADER SIZING CHART. w DRIPLINE SPACING AS - NOTED. TYPICAL TECHLINE TUBING I I I z I LATERALS WITH EMITTER E5 I I I SPACING AS NOTED. LL I I I STAPLE (TLS6) AT ALL TEES, ELLS, AND AT S O.C. AT H = I I I CLAY, 4' O.C. AT LOAM, OR 3' z w l I I O.C. AT SAND. LU J C/) �Q 2 I I MANUAL LINE FLUSHING a F_ VALVE PLUMBED TO J I I I EXHAUST HEADER, AS FAR F END FEED EXAMPLE FROM THE SUPPLY HEADER AS POSSIBLE. w J c� z Fn O Q ~ U z w J (n J w 1­- FLUSHING VALVE AT F EACH EXHAUST END. CENTER FEED EXAMPLE TYPICAL NETAFIM TECHLINE CV REQUIREMENTS N.T.S. 1" METAL CONDUIT WITH LONG SWEEP ELL FOR 110V POWER SOURCE AS PER ELECTRICAL CODES EV-CAB-COM CABLE IF APPLICABLE. INSTALL IN 1" CONDUIT 8 FT. COPPER GROUND AS PER LOCAL CODE a. z / r ao KEEP 12' APART g ELECTRIC AUTOMATIC CONTROLLER AS SPECIFIED. WALL MOUNTED BRACED PER MANUFACTURER (SEE IRRIGATION PLAN FOR LOCATION) 2" DIA. SCH. 40 PVC CONDUIT WITH LONG SWEEP ELL FOR OF DIRECT BURIAL WIRES TO VALVES. ALLOW A MAXIMUM OF 24 WIRES PER CONDUIT CONCRETE MOUNTING PAD, EXTEND 6" BEYOND OUTSIDE DIMENSIONS OF CONTROLLER. SLOPE FOR DRAINAGE CONTROLLER WALL MOUNT 1/2" = V-0" P-2-G RA-61 PEDESTAL PAVERS, SEE ARCH. BRASS GATE VALVE TO BACKFLOW PREVENTER ALL PIPE TO DCVA COPPER OR BRASS WATERPROOFING, SEE ARCH. PLUMBING THROUGH ROOF, SEE ARCH. " . BRASS WATER SUPPLY FROM BUILDING, SEE MECH. POC UNDER ROOF PAVERS 1 1/2" = V-0" Know what's below. Call before you dig. TECHLINE CV MAXIMUM LENGTH OF SINGLE LATERAL (FEET) DRIPPER SPACING 12" 18" 24" DRIPPER FLOW 0.26 0.4 0.6 0.9 0.26 0.4 0.6 0.9 0.6 0.9 RATE (GPH) � 15 127 109 86 65 177 151 120 91 152 116 Z) LJj 25 427 325 256 194 604 459 361 274 458 348 35 539 409 322 244 763 579 456 346 580 440 a wN z a 45 618 469 369 280 877 664 523 397 666 506 TECHLINE FLOW PER 100 FEET DRIPPER SPACING 0.26 GPH DRIPPER 0.4 GPH DRIPPER 0.6 GPH DRIPPER 0.9 GPH DRIPPER GPH GPM GPH GPM GPH GPM GPH GPM 12" 26.40 0.44 40.00 0.67 61.00 1.02 92.00 1.53 18" 17.58 0.29 26.67 0.44 41.00 0.68 61.00 1.02 24" N/A N/A N/A N/A 31.00 0.51 46.00 0.77 SUPPLY AND EXHAUST HEADER SIZING CHART (UNLESS NOTED ON PLANS) STEP 1: ADD LENGTH OF ALL TECHLINE LATERAL TUBING CONNECTED TO THE HEADER. STEP 2: DIVIDE THIS TOTAL LENGTH BY 100 TO INDICATE THE LENGHT IN UNITS OF 100. STEP 3: LOCATE THE GPM THAT APPLIES FOR EACH UNIT OF 100 FEET LENGTH ON THE CHART "TECHLINE FLOW PER 100 FEET". MULTIPLY THIS GPM NUMBER TIMES THE UNITS OF 100 FEET FOR THE TOTAL GPM AT THIS HEADER. STEP 4: SIZE THE HEADER WITH THE FOLLOWING: 1 TO 6 GPM: 3/4" HEADER. 6 TO 10 GPM: 1" HEADER. 10 TO 20 GPM: 1 1/4" HEADER. 20 TO 30 GPM: 1 1/2" HEADER. 1'-6" \/ 10 v �0 = I 1=1 11=1 11=1 11=1 I -III- -I 11=1 11= IIII� III=III=III=III-III=III=III=III-III=_ 11 11 111 111 111 111 111 111 111 111 1I- DRIPLINE HEADER 1 1/2" = V-0" BLDG, SEE ARCH. I1� .. , •60 . 1 " = V-0" KEEP CONTAINERS LEVEL WITH ADJACENT BLDG HOLD SOIL 2" BELOW TOP OF PLANTER 921901l:i9 GEOTEXTILE FILTER FABRIC PLANTER, SEE ARCHITECT 1/2" IRRIGATION POLY FLEX PIPE RECORD NOTE 04/25/2024 THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON INFORMATION SUBMITTED, IN PART, BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, AHBL IS NOT RESPONSIBLE FOR ITS ACCURACY, OR ERROR OR OMISSIONS ` _ g'°ee Sf a bd Engineers d0°5Ld°eA bNe�S Cem dyP1en 4 5 6 7 WHICH MAY HAVE BEEN INCORPORATED INTO THIS DOCUMENT � Q Q `vghbnrveYersors 8 AS A RESULT. THOSE RELYING ON THIS RECORD DOCUMENT Neighb ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. 22 A C O M A 30 E A T T 98 E 2215 North 30th Street, Suite 300, Tacoma, WA 98403 1200 Sixth Avenue, Site 1620, Seaule,WA98101 283.383.2422 TEL 2"2" 425 TEL NO. TECHLINE CV GENERAL GUIDELINES FOR WATERING TIME TURF SHRUB & GROUND COVER CLAY LOAM SANDY CLAY LOAM SANDY DIPPER FLOW (GPH) 0.26 0.4 0.6 0.26 0.4 0.6 DRIPPER INTERVAL 18 12 12 18 18 12 LATERAL (ROW) SPACING 18"-22" 18"-22" 12-16 18"-24" 18"-24 16"-20" APPLICATION RATE (IN/HR) .19-0.15 .43-.35 .96-.72 .19-.21 .29-.21 .72-.58 TIME TO APPLY 1 /4" 79-100 35-43 16-21 79-107 52-71 21-26 PERMIT REVISION V.1 PERMIT REVISION CORRECTIONS V.2 PROGRESSIVE CONSTRUCTION SET CONSTRUCTION SET AS -BUILT REVISIONS REVISION WATER SOURCE DRIP VALVE OR LATERAL FROM VALVE. TYPICAL SUPPLY PIPE. TYPICAL TECHLINE DRIPPER LINE TUBING. TYPICAL PVC SUPPLY OR EXHAUST HEADER. F MANUAL LINE FLUSHING VALVE PLUMBED TO PVC HEADER. ISLAND LAYOUT 0 PVC PIPE SUPPLY OR EXHAUST HEADER 2O PVC TEE (SXSXT) 3O TECHLINE 3/4" MALE ADAPTER 4O BLANK TECHLINE TUBING 5O TECHLINE DRIPLINE 1 IQ L3.3 6O TECHLINE ELBOW 7O FINISH GRADE O MULCH 9O TOPSOIL 10 BLENDED SOIL 11 SCARIFIED SUBGRADE E.H. 7/29/22 SURVEYED: T.L. E.H. 1 1 / 1 8/22 DESIGNED: A.G. E.H. 2/07/22 MS 04/03/23 DRAWN: A.G. MM 04/25/24 CHECKED: C.S. BY DATE APPR APPROVED: P-2-G RA-82 IRREGULAR ODD CURVES IRREGULAR \ AREAS: TRIANGULAR \ SUPPL HEADE ` 1 EXHAUST HEADER F F TOTAL THE COMBINED LENGTH CHECK LONGEST OF THESE LATERALS AND LATERAL AGAINST COMPARE TO THE CHART FOR CHART FOR MAX. MAX. LENGTH OF SINGLE LENGTH OF SINGLE LATERAL. LATERAL BRANCHING OUT JOINING LATERALS LATERALS 10" ROUND PVC BALL VALVE, VALVE BOX SAME SIZE AS HEADER •�i ��IIi �' li\- �� 1, 1��.'I�� �I \\� III. SCALE: PER SHEET ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 0 / /FTYPICAL START CONNECTION ON EXHAUST HEADER. TOTAL LENGTH OF TECHLINE TUBING IN THIS AREA CAN NOT EXCEED THE MAX. LENGTH OF RUN. TYPICAL START CONNECTION ON SUPPLY HEADER. SEE SUB -HEADER J l DETAIL. - - - - - - - TYPICAL TECHLINE START CONNECTION. PARKING ISLAND TYPICAL LAYOUT MANUAL LINE FLUSHING VALVE. TOP OF SLOPE. TECHLINE CV LATERAL TUBING. PVC SUPPLY LATERALS PARALLEL TO THE HEADER. CONTOURS OF THE SLOPE. PVC EXHAUST HEADER. TOE OF 54" MAXIMUM ELEV. SLOPE. CHANGE WITHOUT CHECK VALVE. IF GREATER, TOP 2/3 OF SLOPE: INSTALL INLINE CHECK CONVENTIONAL VALVES EVERY 54" IN ELEV. SPACING. CHANGE. BOTTOM 1/3 OF SLOPE: CONVENTIONAL SPACING PL S 25%. SLOPE FEED LAYOUT REMOTE CONTROL VALVE ASSEMBLY. DRIPLINE HEADER PIPE FILTER FABRIC WASHED DRAIN ROCK MANUAL LINE FLUSHING VALVE 1 1/2" = V-0" 19 NOR ONI NAD NAVD1983//11991 DATU M P-2-G RA-114 O W A S( �P\G R . S /�/A �o oti 1 EX P . 031 S cq PE ARG 04/26/2024 f CITY OF RENTON [;R Planning/Building/Public Works Dept. P-2-G RA-81 R-420036 IN COMPLIANCE WITH CITY OF RENTON STANDARDS WATERSHED APARTMENTS CONSTRUCTION SET DRAFT IRRIGATION DETAILS DATE: 03/28/202 FIELDBOOK: PAGE: L3.3 SHEET: OF: 46 48 Ln LO T O C) N