HomeMy WebLinkAboutR-420036O O i O i w CD I- Z Cw G rr Q n Q w cn rr w Q 0 N I IXVIVI IVIL I LI\ INJ IV - I LIN V-VL DCVA BACKFLOW PREVENTER 1 1 /2" = V-0" MAIN LINE 00 0 00 0o FILTER FABRIC, WRAP UP ALL SIDES 2 CU. FT. WASHED ��n �o�°n ABOVE OPENINGS'oo0°OoO DRAIN ROCK 6X2X16 CONC. BLOCK, ONE PER CORNER (4 TOTAI NOTES: 1. USE VALVE BOX W EXTENSIONS. SET 2" ABOVE GRADE IN SHRUBS, FLUSH IN TURF 2. USE TEFLON TAPE FOR ALL THREADED FITTINGS, NO PIPE DOPE 3. KEEP MIN. 3" CLEARANCE AROUND VALVE ON ALL SIDES. 4. LEAVE EXTRA 30" CONTROL WIRE COILED INSIDE VALVE BOX 5. USE DBR WATERPROOF CONNECTORS REMO�ECONTROL VALVE v J 1 1 /2" = V-0" BRASS NIPPLE DCVA, SEE SPEC. BRASS GATE VALVE BLOW OUT QUICK COUPLER ON BRASS 'IT" AND BRASS NIPPLE GQ d' UOy 0 0 Know what's b@IOW. Call before you dig. Will o;lo. ff.olf.'Miii ism SCHEDULE 80 UNION I I SUPPORT MIN. 2" CLR BLOCKING ABOVE AND PIPE THROUGH ROOF BELOW SLAB, SEE ARCH. ALL BRASS OR TYPE K COPPER PIPE AND FITTINGS BEFORE THE DCVA AND QUICK COUPLER. BASS BALL VALVE, INTERIOR SHUT OFF NOTE: 1. USE TEFLON TAPE ON ALL THREADED FITTINGS. NO PIPE DOPE. 2. INSTALL DCVA UNDER A PAVER WHICH CAN BE EASILY REMOVED. DCVA UNDER ROOF PAVERS 1 1 /2" = V-0" 91 21 b - ALL BRASS PIPE AND FITTINGS FROM DCVA 2 CU. FT. WASHED DRAIN ROCK MASTER VALVE 1 1 /2" = V-0" UNION �C? MAIN LINE ) - 0o - - - u- nY�- ( o 0 FILTER FABRIC, WRAP UP ALL SIDES 2 CU. FT. WASHED � n �0 q0 98 �o ABOVE OPENINGS -,D_ o ( DRAIN ROCK 6X2X16 CONC. BLOCK, ONE PER CORNER (4 TOTAL) NOTES: 1. USE VALVE BOX W EXTENSIONS. SET 2" ABOVE GRADE IN SHRUBS, FLUSH IN TURF 2. USE TEFLON TAPE FOR ALL THREADED FITTINGS, NO PIPE DOPE 3. KEEP MIN. 3" CLEARANCE AROUND VALVE ON ALL SIDES. 4. LEAVE EXTRA 30" CONTROL WIRE COILED INSIDE VALVE BOX 5. USE DBR WATERPROOF CONNECTORS DRIP REMOTE CONTROL VALVE 1 1 /2" = V-0" /O Cj Civil Engineers R.sk�A"V^ St-bralEngineers A� Lantlscape Archltecls Community Planners Land Surveyors 'zo 10ors ory v ti loan Neighb 2 3�p5���� scq P TACO MA - S EATTLE tip\ 1200 Sixth Avenue, Suite ta 1620, Seattle, WA 98101 206.267.2425 TEL p EA ?- VALVE SCHEDULE GENERAL IRRIGATION NOTES 1. NO SUBSTITUTIONS OF EQUIPMENT OR DESIGN CHANGES SHALL BE PERMITTED UNLESS APPROVED BY THE OWNER. 2. IRRIGATION LINES AND VALVES MAY BE SHOWN IN HARD SURFACE AREAS OR OUTSIDE LANDSCAPE AREAS FOR GRAPHIC CLARITY. LOCATE ALL IRRIGATION LINES IN LANDSCAPE AREAS OR IN SLEEVES UNDER PAVEMENT. 3. IRRIGATION CONTRACTOR SHALL COORDINATE INSTALLATION OF IRRIGATION CONDUIT AND SLEEVES UNDER HARD SURFACES WITH RESPECTIVE CONTRACTORS. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS, TESTS, AND INSPECTIONS REQUIRED FOR THE IRRIGATION SYSTEM. 5. CALL FOR LOCATES PRIOR TO DIGGING AT CONTRACTOR IS RESPONSIBLE TO VERIFY UTILITY LOCATIONS. IF UTILITIES ARE DAMAGED IN THE COURSE OF WORK, CONTRACTOR SHALL INFORM THE OWNER AND MAKE ANY REPAIRS REQUIRED, AT NO COST TO THE OWNER. 6. ALL SLEEVING SHALL BE MARKED, SEALED AND STAKED. ALL SLEEVES SHALL BE TWICE THE SIZE OF OF THE LINE OR COMBINED LINES. MINIMUM SLEEVE SIZE SHALL BE 4-INCHES IF LOCATED UNDER ROADWAY OR DRIVE AISLE. 7. COORDINATE SLEEVING LOCATIONS WITH ELECTRICAL CONDUIT. 8. SPLICE CONTROL WIRES WITHIN VALVE BOXES ONLY, USING 3M-DBY, OR APPROVED SPLICE KITS, AND PROVIDE A 30" EXPANSION LOOP FOR ALL CONTROL WIRES WITHIN EACH VALVE BOX. KEEP WIRE SPLICES TO A MINIMUM. PROVIDE CLEAN WIRE CUTS WITH NEW SPLICE KITS AT ALL SPLICES INCLUDING ANY SPLICE THAT IS DISCONNECTED AND RECONNECTED FOR ANY REASON OR PERIOD OF TIME. 9. VALVE BOXES SHALL BE COMMERCIAL -GRADE POLYETHYLENE OR HDPE AND SUITABLE FOR LIGHT DUTY APPLICATIONS. 10. INSTALLER TO ADJUST ALL ZONE CONTROL VALVES TO THE CORRECT OPERATING PRESSURE. SEE VALVE SCHEDULE FOR OPERATING PSI. 11. CONTRACTOR SHALL HAND TRENCH IRRIGATION DITCHES WHEN WITHIN 20 FEET, OR WITHIN A DELINEATED ROOT PROTECTION ZONE, OF EXISTING TREES TO REMAIN. AVOID CUTTING ANY ROOTS OVER 3" - 4" IN DIAMETER WITHIN THE ROOT PROTECTION ZONE. 12. INSTALLER SHALL BE RESPONSIBLE FOR KEEPING EXACT ACCURATE NOTES AND "AS-BUILTSII FOR THE CREATION OF THE "RECORD DRAWINGS" OF THE INSTALLED SYSTEM. 13. CONTRACTOR SHALL PROVIDE IRRIGATION MAINTENANCE THROUGH THE PLANT ESTABLISHMENT PERIOD INCLUDING WINTERIZATION(S) AND SPRING START-UP(S). CRITICAL ANALYSIS Generated: 2022-04-21 08:11 P.O.C. NUMBER: 01 Water Source Information: NEW WATER METER- SEE CIVIL FLOW AVAILABLE Water Meter Size: 1" Flow Available 37.5 GPM WVX*01:1CF-I _11!_11.1no Static Pressure at POC: 72.00 PSI Elevation Change: 5.00 ft Service Line Size: 3" Length of Service Line: 20 ft Pressure Available: 70.00 psi DESIGN ANALYSIS Maximum Station Flow: 13.84 GPM Flow Available at POC: 37.5 GPM Residual Flow Available: 23.66 GPM Critical Station: 6 Design Pressure: 25 PSI Friction Loss: 2.33 PSI Fittings Loss: 0.23 PSI Elevation Loss: 0 PSI Loss through Valve: 11.68 PSI Pressure Req. at Critical Station: 39.26 PSI Loss for Fittings: 0.53 PSI Loss for Main Line: 5.35 PSI Loss for POC to Valve Elevation: 0 PSI Loss for Backflow: 6.95 PSI Loss for Master Valve: 1.08 PSI Loss for Water Meter: 1.08 PSI Critical Station Pressure at POC: 54.25 PSI Pressure Available: 70 PSI Residual Pressure Available: 15.75 PSI NUMBER MODEL SIZE TYPE GPM PSI PSI @ POC PRECIP 1 DRCV 1" SHRUB DRIPLINE 0.6 GPH @ 18" O.C. (2.3 L/H @ 0,46M) 1.64 26.71 32.14 0.69 in/h 2 DRCV 1" SHRUB DRIPLINE 0.6 GPH @ 18" O.C. (2.3 L/H @ 0,46M) 5.63 30.44 37.05 0.69 in/h 3 RCV 1" TREE BUBBLERS RWS 8.43 33.22 43.44 0.9 in/h 4 DRCV 1" SHRUB DRIPLINE 0.6 GPH @ 18" O.C. (2.3 L/H @ 0,46M) 3.01 27.38 33.36 0.69 in/h 5 RCV 1" TREE BUBBLERS RWS 1.60 31.41 36.92 1 in/h 6 DRCV 1" SHRUB DRIPLINE 0.6 GPH @ 18" O.C. (2.3 L/H @ 0,46M) 13.84 39.24 54.25 0.69 in/h 7 RCV 1" TURF ROTATOR (HUNTER) 7.05 42.84 51.04 0.45 in/h 8 RCV 1" TREE BUBBLERS RWS 2.24 31.58 37.17 1 in/h 9 RCV 1" TURF ROTATOR (HUNTER) 0.83 41.22 46.65 0.45 in/h 10 RCV 1" SHRUB DRIPLINE 0.6 GPH @ 18" O.C. (2.3 L/H @ 0,46M) 0.88 26.24 31.67 0.69 in/h 11 DRCV 1" SHRUB DRIPLINE 0.6 GPH @ 18" O.C. (2.3 L/H @ 0,46M) 5.20 30.2 36.5 0.69 in/h 12 RCV 1" TREE BUBBLERS RWS 6.94 33.57 40.39 1 in/h 13 DRCV 1" TREE BUBBLERS RWS 6.65 36.68 43.29 0.85 in/h 14 DRCV 1" 0.00 1 6.5 Unknown 15 DRCV 1" 0.00 1 6.5 Unknown 16 DRCV 1" 0.00 1 6.5 Unknown 17 RCV 1" 0.00 0.8 6.3 Unknown 19 DRCV 1" 0.00 1 6.5 Unknown 20 DRCV 1" 0.00 1 6.5 Unknown 1 PERMIT REVISION E.H. 3/18/22 SURVEYED: T.L. SCALE: PER SHEET 2 PERMIT REVISION E.H. 4/25/22 DESIGNED: M.S. 3 PERMIT REVISION E.H. 5/12/22 DRAWN: E.H. ONE INCH CHECKED: C.T. AT FULL SCALE IF NOT ONE INCH NO. REVISION BY DAT E A P P R SCALE ACCORDINGLY APPROVED: VERTICA:19 NOR ON ALL NAD D1983//11991 DATU M GROUND LEVEL POINT OF CONNECTION NOTES 1. CONTRACTOR SHALL VERIFY EXISTING STATIC PRESSURE AT THE METER AND SUBMIT WRITTEN VERIFICATION TO THE LANDSCAPE ARCHITECT. NOTIFY THE LANDSCAPE ARCHITECT OF DISCREPANCIES GREATER THAN 5 POUNDS OF DESIGN PRIOR TO INSTALLATION OF ANY IRRIGATION EQUIPMENT. 2. POC NUMBER 01: 1" NEW DEDICATED METER. 2.1. THE SYSTEM DESIGN IS BASED ON OPERATING 1 ZONE AT A TIME USING A NEW IRRIGATION METER ON A 1" SCH. 40 PVC SUPPLY LINE. CONTRACTOR SHALL FIELD VERIFY SIZE AND LOCATION. 3. COORDINATE METER SCOPE OF WORK WITH ALL APPLICABLE TRADES. INSTALL METER PER KING COUNTY WATER DISTRICT 90 STANDARDS. 4. IRRIGATION CONTRACTOR SHALL TIE INTO METER AND RUN PIPE TO BACKFLOW PREVENTER. INSTALL BACKFLOW PREVENTER ON PRIVATE PROPERTY AS CLOSE TO THE METER AS POSSIBLE. 5. NOTIFY THE OWNER IMMEDIATELY IF THE POINT OF CONNECTION ASSUMPTIONS MADE HERE DO NOT MATCH FIELD CONDITIONS. 6. CONTRACTOR SHALL APPLY AND PAY FOR ALL REQUIRED PERMITS, INCLUDING A SEPARATE BACKFLOW PREVENTER (DCVA) PERMIT 7. CONTRACTOR TO PROVIDE DCVA TESTING ROOFTOP IRRIGATION NOTES 1. SEE APPLICABLE GENERAL IRRIGATION NOTES. 2. IRRIGATION CONTRACTOR SHALL COMPLY WITH APPLICABLE BUILDING AND PLUMBING CODES FOR IRRIGATION PIPING AND EQUIPMENT INSIDE AND ON TOP OF STRUCTURES. COORDINATE WITH APPLICABLE TRADES PRIOR TO BIDDING. 3. PROVIDE SHOP DRAWING(S) OF INTERIOR IRRIGATION EQUIPMENT SHOWING CONFIGURATION AND COORDINATION WITH OTHER PROPOSED EQUIPMENT. 4. TO THE EXTENT POSSIBLE, IRRIGATION PIPING SHALL BE CONCEALED IN OCCUPIED SPACES. PVC PIPE SHALL BE COVERED OR WRAPPED AND SHALL NOT BE EXPOSED TO SUN. STUB -UPS AND STUB -OUTS SHALL BE CONCEALED BY PEDESTAL PAVERS OR PLANTERS. 5. HEADS MUST BE VERTICAL AND SECURE. PROVIDE HEADS ON EL IF REQUIRED TO PREVENT LATERAL LINE FROM TWISTING. 6. PROVIDE LAMINATED PLAN IN CONTROLLER BOX SHOWING EQUIPMENT LOCATIONS UNDER PEDESTAL PAVERS. PLAN SHALL CLEARLY INDICATE WHICH PAVER IS TO BE REMOVED FOR ACCESS. 7. VALVES, BACKFLOW PREVENTERS AND PIPING SHALL BE PLACED UNDER PEDESTAL PAVERS ONLY WHERE AT LEAST 2" CLEARANCE IS AVAILABLE. WHERE NO LOCATION PERMITS, PLACE VALVES AND BACKFLOW PREVENTERS IN VALVE BOXES IN BEDS OR WALL MOUNT WHERE NOT VISIBLE TO USERS IN ACCESSIBLE SPACE. GET APPROVAL OF LOCATION FROM LANDSCAPE ARCHITECT BEFORE INSTALLING. DRIP IRRIGATION NOTES 1. SEE APPLICABLE GENERAL IRRIGATION NOTES. 2. DO NOT EXCEED MAXIMUM VERTICAL DISTANCE BETWEEN PRESSURE CONTROL VALVES RECOMMENDED BY MANUFACTURER. 3. DRIP LINE HATCH DIRECTION AND SPACING ON PLANS IS DIAGRAMMATIC. PLACE PER DETAILS, LEGEND, AND MANUFACTURER'S RECOMMENDATIONS. 29. IRRIGATION CONTRACTOR SHALL INSTALL PROVISIONS FOR WINTERIZATION BY PROVIDING BOTH MANUAL DRAINS AT ALL LOW POINTS (AUTOMATIC DRAIN VALVES ARE NOT PERMITTED) AND A MEANS TO BLOW OUT IRRIGATIONS SYSTEM PIPES WITH PRESSURIZED AIR. SLOPE PIPE AT 1/21, MIN. TO DRAINS. PRESSURIZED AIR NOT TO EXCEED 20 PSI ON DRIP IRRIGATION LINES. 31. INSTALL AIR RELIEF VALVES PER MANUFACTURER'S RECOMMENDATIONS, IN CONTROL VALVE BOXES. 32. INSTALL DRIP LINES ACCORDING TO MANUFACTURER'S INSTRUCTIONS. NO DRIP TUBING SHALL BE LEFT EXPOSED. I CITY OF RENTON Plonning/Building/Public Works Dept. R-420036 IN COMPLIANCE WITH CITY OF RENTON STANDARDS EMotRENTPLANNING ganroth 05+I7f2R22 01 WATERSHED APARTMENTS CIVIL CONSTRUCTION PERMIT IRRIGATION DETAILS DATE: 03/18/2022 FIELDBOOK: PAGE: L3.2 SHEET: 45 OF:46 Ln T T L0 O O T N LIJ 1►+'1 H H T N Q J