HomeMy WebLinkAboutW-420003z J Li 0 a N' N' n rr ►E VB #2 z LU 75 G 14 LF 10" DIP CL 52 rr PROPOSED ROW DEDICATION a n VB #1 Q 4LF10"DIP CL52 0 STA: 5+03.00 5 w 1 - 10" 22.5° BEND (MJ x MJ) 1 - THRUST BLOCK (� 3 @CONNECT U-1 STA: 5+00.00 TO EXISTING WATER MAIN 25 Q CITY FORCES) PER COR STD PLAN 300.1 1 - 18" x 10" TAPPING TEE (MJ x FL) 1 - 10" TAPPING GATE VALVE (FL x MJ) 20 1 - THRUST BLOCK 7 2.28' PROPOSED SEWER PROFILE 1 SCALE: 1" = 20' H 1"=10'V 35 INSTALL WARNING TAPE OVER SHALLOW PORTION OF THE WATER MAIN (WHEREVER COVER IS LESS THAN 3-FEET) 6" DI STORM BOT 29.49 ETHAFOAM PAD STA: 5+35.31 1 - 10" 45° BEND (MJ x MJ) -1 - THRUST BLOCK PROPOSED GRADE AT WATER q -------------I-- 1.5' MI STA: 6+44.70 1 - 10" 11.25' BEND (MJ x MJ) 1 - THRUST BLOCK j EXISTING GRADE I AT WATER cL IN AREAS OF FILL, NEW PARKING LOT AND/OR ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION FOR INSTALLATION OF NEW WATER MAIN. 1.5' MIN O c. 1` Ib N �� M o N 00 O U) O - Ln 't Qa� Q Q N QC� Q Q M Q OR rr1 co M co I� co n CV co pry Cl) n co M ro co 04 co N CV co N M N M c� 0 i 0 0 i 0 0 00 00 00 0 0 0 W LL W Ll- W LL W LL W LL W LL W LL W LL W LL W LL 5+50 6+00 6+50 7+00 7+50 DEFLECTIONS AS NECESSARY, PER HALF MANUFACTURERS RECOMMENDATIONS TO PROVIDE MINIMUM 2.0' OF COVER AND MAXIMUM 5.0' OF COVER 7 LF 10" DIP CL PROPOSED GRADE STA: 9+01.47 AT WATER q 1 - 10" x 6" TEE (FL x FL) 1 - 6" GATE VALVE (F L x MJ) 1 - 10" GATE VALVE (F Lx MJ) 1 - 10" FL x MJ ADAPTER STA: 8+12.97 1 - THRUST BLOCK 1- 10" 11.25' BEND (MJ x MJ) 1 - THRUST BLOCK PROPOSED EXISTING GRADE STORM"* AT WATER PROPOSED PIP1 301--- 17 ------------1— r- 1.6V 25 20 PROFILE 2 SCALE: 1" = 20' H 1"=10'V ®R Know what's below. Call before you dig. STA: 9+08.47 1 - 10" x 6" TEE (FL xFL) 1 - 6" GATE VALVE (F L x MJ) 1 - 10" GATE VALVE (F L x MJ) 1 - 10" FL x MJ ADAPTER 1 - THRUST BLOCK 5.67' 51' IN AREAS OF FILL, NEW PARKING LOT AND/OR ROADWAY SUBGRADE SHALL BE FILLED AND COMPACTED BEFORE EXCAVATION FOR INSTALLATION OF NEW WATER MAIN. PROPOSED ROW DEDICATION INSTALL 84 LF OF 10" D.I. RESTRAINED JOINT WATER MAIN APPROX. LOCATION OF EXISTING POWER 39 LF 10" DIP CL 52 18" STORM BOT 27.09 APPROX. LOCATION OF EXISTING GAS M O O M N W- M- Ln O 0 O O CN � M 00 00 o O o O o O M M to M K) M M j co co Cn 0 W LL W LL W LL W LL W Ll- W LL Ld LL W LL W LL W 8+50 9+00 9+50 10+00 10+50 DEFLECTIONS AS NECESSARY, PER HALF MANUFACTURERS RECOMMENDATIONS TO PROVIDE MINIMUM 3.0' OF COVER AND MAXIMUM 6.0' OF COVER STA: 7+71.77 1 - 10" 90° BEND (MJ x MJ) 1 - THRUST BLOCK 5 LF 10" DIP CL 52 STA: 7+87.02 1 - 10" x 6" TEE (FL x FL) 1 - 6" GATE VALVE (FL x MJ) 1 - 10" GATE VALVE (FL x MJ) 1 - 10" ADAPTER (FL x MJ) 1 - THRUST BLOCK 35 ---�30 25 20 ff) o Q CV N C0 Q 0 L1J LL 35 STA: 10+63.73 CONNECT TO EXISTING WATER MAIN 2 - - - 30 CUT IN TEE (BY CITY FORCES) PER COR STD PLAN 300.4 C6.40 1 - 12" x 10" TEE (FL x FL) 1 - 10" GATE VALVE (FL x MJ) 25 2 - 12" GATE VALVE (FL x MJ) 2 - 12" SOLID SLEEVES (MJ) 1 - 10" SOLID SLEEVE (MJ) 20 1 - THRUST BLOCK W Lei *"STORM DRAIN AT CROSSING SHALL BE CL 52 DI. CENTER OF WATER MAIN PIPE AND STORM DRAIN PIPE SHALL BE CENTERED AT THE CROSSING POINT TO MAXIMIZE THE DISTANCE OF THE PIPE BELLS FROM THE CROSSING JOINT. WA gg�andseaPeAr� � O T A C O M A • S E A T T L E 2215 North 30th Street, Suite 300, Tacoma, WA 98403 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 GPI Engineers Shuctural Engineers le �n m��ryPlanners Land Surveyors Neighbors 253.383.2422 TEL 206.267.2425 TEL 1 PERMIT REVISION 2 PERMIT REVISION 3 PERMIT REVISION N O REVISION JN 3/18/22 DT SURVEYED: T.L. JN 4/25/22 DT DESIGNED: J.N. JN 5/12/22 DT DRAWN: J.N. CHECKED: DT BY DATE APPR APPROVED: SCALE: PER SHEET ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1083/1091 DATU M VERTICAL BEND TABLE VB # STATION DESCRIPTION STA: 5+04.17 VB #1 1-10" 11.25° VERTICAL BEND (MJ X MJ) 1- THRUST BLOCK STA: 5+17.73 VB #2 1- 10" 11.25° VERTICAL BEND (MJ X MJ) 1- THRUST BLOCK 0712612022 CITY OF RENTON 1-`R i4siv Planning/Building/Public Works Dept. LO T T LO C) 0 T N Al u 1►�'1 H H H H T N rr n W-420003 I co IN COMPLIANCE WITH CITY OF RENTON STANDARDS z Z w LDEVELOPMENT ENGINEERING r JChavez 07/27/2022 a n DAM, LU WATERSHED APARTMENTS 03/18/2022 = CIVIL CONSTRUCTION PERMIT FIELDBOOK: U) PAGE DRAWING NO: LU WATER PROFILE AND NOTES C6.20 Q SHEET: OF: 20 46