HomeMy WebLinkAboutW-420007nI AAI O O N LU VJ I— Z LU G rr ^a n a 0 LU �r_ VJ LU a CJ LL BUILDING NG -DA OR RPDA 1350.3 OR 360.4 M �R MAIN (1) TEE (FLxFL) (3) GATE VALVES (FLxMJ) WITH CONCRETE BLOCKING NOTES: 1. FIRE SPRINKLER SYSTEM SHALL BE LOCATED ON DEDICATED FIRE SERVICE SEPARATE FROM DOMESTIC SERVICE TO THE BUILDING. 2. PIV MUST BE LOCATED ON THE FIRE SERVICE BETWEEN THE ROW AND THE FDC. 3. FIRE MARSHAL SHALL APPROVE FDC AND/OR PIV LOCATION IF LESS THAN 50, FROM BUILDING. 4. THE DCDA OR RPDA MUST BE TESTED BY A WASHINGTON STATE CERTIFIED BACKFLOW ASSEMBLY TESTER UPON INSTALLATION AND ANNUALLY THEREAFTER. ASSEMBLY TO BE MAINTAINED BY PROPERTY OWNER. A COPY OF THE TEST REPORT SHALL BE SENT TO THE CITY OF RENTON WATER UTILITY CROSS CONNECTION CONTROL SPECIALIST, FAX 425-430-7241, EMAILMHOLTE@RENTONWA.GOV. 5. THE FDC AND PIV MAY BE LOCATED WITHIN THE VAULT WITH THE BACKFLOW ASSEMBLY PER STD PLAN 370.3. PUBLIC WORKS COMMERCIAL FIRE SPRINKLER SYSTEM APPROVED: STD. PLAN - 370.2 o - DEPARTMENT 3„ TO 10„ DCDA OR RPDA OUTSIDE INSTALLATION Ma,t Pas ha Pubu, Work: Ad,i is m DATE COMMERCIAL FIRE SPRINKLER NOT TO SCALE MATERIALS OA WALL FLANGE OB BLOCKING OC PIPE PENETRATION OD GRAVEL PROFILE 24" MIN MIDSPAN PIPE RESTRAINT, EBAA IRON SERIES 110OSDB MEGALUG OR EQUAL, WRAP WITH POLYETHYLENE ENCASEMENT PRIOR TO PLACEMENT OF CONCRETE BLOCKING CONCRETE THRUST BLOCKING, CAST -IN -PLACE CONCRETE (MINIMUM 3,000 PSI), TO BE SIZED BY DESIGN ENGINEER (MINIMUM 24"x24"x6i') CORE DRILL (O.D. +2") VAULT IF KNOCKOUTS ARE NOT PROVIDED, SEAL PIPE PENETRATION WITH WATER -TIGHT GROUT FOUNDATION GRAVEL PER WSDOT STANDARD SPECIFICATIONS, 12" MINIMUM ALL DIRECTIONS STD. PLAN - 370.4 + PUBLIC WORKS CONCRETE BLOCKING APPROVED: DEPARTMENT ADJACENT TO VAULT m t,m Pzs hz DATE Public Works Adminl, ra CONCRETE BLOCKING ADJACENT TO VAULT NOT TO SCALE .A .a a' a ., r----- —T— ------ �16"� ad A I HINGE HINGE Il ACCESS HATCH �I (SEE NOTES 4 & 5) I a I I I I I L — — — — — — — l — — — — — — — J d a. A PROFILE FIRST STEP 8" TO 12" BELOW TOP OF COVER CONCRETE MECHANICAL ANCHOR BOLT, GALVANIZED OR STAINLESS STEEL (TYP.) SIDE RAIL AND BRACKET 1Y2" x X" GALVANIZED STEEL (TYP.) RUNG, NO. 8 DEFORMED REINFORCING BAR CONFORMING TO ASTM A615 4" MIN PVC DRAIN TO DAYLIGHT OR STORM DRAIN SYSTEM, WIRE MESH RODENT SCREEN OVER DRAIN in J NOTES: 1. VAULTS SHALL ONLY BE INSTALLED IN SHOULDERS, SIDEWALKS, OR LANDSCAPED AREAS. VAULTS SHALL NOT BE INSTALLED IN AREAS WITH VEHICULAR TRAFFIC. VAULT COVER SHALL READ "WATER". 2. LADDER TO BE SECURED TO VAULT WALL AT THREE LOCATIONS: TOP, MIDDLE, AND BOTTOM. 3. ALL LADDER PARTS TO BE GALVANIZED CONFORMING TO ASTM A123. 4. ACCESS HATCH SHALL BE LOCKING ALUMINUM DOUBLE DOORS, LW PRODUCTS CO. MODEL HHD-1C OR HHD-2D AS REQUIRED, RATED FOR H-30 LOADING WITH ASLIP RESISTANT TREATMENT AS FOLLOWS: THERMION, SAFTRAX TH604 GRADE #2 MODERATE TEXTURE - SLIPNOT, GRIP PLATE GRADE 2 (MEDIUM) STEEL - HARSCO IKG, MEBAC#1 GRATING PACIFIC, ALGRIP SLIP -RESISTANT FLOOR PLATE 5. HATCHES SHALL INCLUDE RECESSED PADLOCK HASP SIZED FOR CITY OF RENTON WATER UTILITY PADLOCKS (CONTACT LW PRODUCTS). 6. LADDER -UP ATTACHMENT REQUIRED ON ALL VAULT LADDERS, BILCO LADDERUP TYPE LU-2. STD. PLAN - 370.5 + PUBLIC WORKS APPROVED: DEPARTMENT VAULT LADDER marcPzs hz DATE Public Works Administrator VAULT LADDER NOT TO SCALE !✓XST OP4j� OF WAskjNCrrti °i Pjlll ��SSIONAL E��1 CiNlEngineers ■J— 001 ASI-001 CJ 9/27/22 DT S"''ED0 scALE sbdu2lEgireers T.L. HORIZONTAL: NAD 1983/1991 — ` Lznds peA,c„Me 002 PROGRESSIVE CONSTRUCTION SET CJ 12/5/22 DT DESIGNED: PER SHEET c°mm°°ilnaie°ders 003 UPDATES PER CONDITIONS OF APPROVAL DT 1/27/23 DT J.N. mm L°°dS°N y°m 004 GRADY WAY STORMWATER REVISIONS CW 12/26/23 TS DRAWN. J.N. NQ19°°°m 005 AS —BUILT REVISIONS AA 03/26/24 TS CHECKED: ONE INCH DATUM Know what's b@IOW. AT FULL SCALE TACOMA • S EATTLE DT IF NOT ONE INCH Ca I I before you dig. 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422 TEL N O. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 206,267,2425 TEL TESTING CONNECTION POLYPIG STATION PER STD PLAN 300.6 - (1) VERTICAL CROSS (MJxFL) (1) BLIND FLANGE ON TOP WITH 2" TAP AND 2" PLUG (1) BLIND FLANGE ON BOTTOM (1) PLUG (MJ) WITH 2" TAP AND TEMPORARY BLOW -OFF ASSEMBLY WITH TEMPORARY THRUST BLOCKING I� 10i± EXISTING WATER MAIN I/ j j�� j % �/j 1,of , EXISTING TEE, CAP, PLUG, TEMPORARY BLOCKING OR DEAD END LINE, DO NOT DISTURB BLOCKING FINAL CONNECTION NEW DI WATER MAIN UPON COMPLETION OF POLYPIGGING, HYDROSTATIC TESTING, AND DISINFECTION, REMOVE TEMPORARY THRUST BLOCKING AND TEMPORARY BLOW -OFF ASSEMBLIES FINAL CONNECTION (BY CITY FORCES) (1) DI SPOOL (1) DI SLEEVE (MJ) NEW DI WATER MAIN STD. PLAN - 300.4 PUBLIC WORKS CONNECTION TO WATER MAIN APPROVED: DEPARTMENT EXISTING TEE OR END LINE CAP + P nn lic ,,k, Az DATE Public Works Administrator CONNECTION REQUIREMENTS NOT TO SCALE RECORD NOTE 03/26/2024 THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON SURVEY INFORMATION PROVIDED BY A THIRD -PARTY SURVEYOR. AHBL WILL BE RESPONSIBLE FOR THE DATA PROVIDED BY THEM. THE THIRD -PARTY SURVEYOR WILL BE RESPONSIBLE FOR THE ACCURACY OF THE ACTUAL LOCATIONS IN THE FIELD. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. CITY OF [;%Rl RENTON Planning/Building/Public Works Dept. Ali H H T N a J H H T N rr 0- W-420007 I � IN COMPLIANCE WITH CITY OF RENTON STANDARDS 7 WATERSHED APARTMENTS CONSTRUCTION DRAFT SET PUBLIC WATER DETAILS LU G a a 0 LU = U) DATE: 03/28/2023 FIELDS", PAGE LU � DRAWING NO: C6.60 a SHEET: OF: 24 48