Loading...
HomeMy WebLinkAboutS-420001NFOUN0.5" RBC !\ : a".I KEYNOTES D 1 "HARSTAD" LS#19731 II WM AT CORNER j I / 3 ° ' O PROPOSED HYDRANT ASSEMBLY PER COR Q i E I CONCWALL. I / i I 1 STD PLN. 310.1. FIRE DEPARTMENT PEAK CONNECT TO WATER MAIN WITH CUT -IN TEE HEIGHT HORIZONTAL DEFLECTIONS AS NECESSARY I �, I ° 4 ° CONNECTION (FDC) =29't PER/ T MMENDATIONS 3 O AND THREE VALVES, PER STD PLAN 300.4. C6. /�/1L1/LL�J/_LL!/ //' / i SS(RE�° TEL. STA:7+89.12, 40.72' LT °/1L/ /11!/ POLE I 3 I CONNECT TO WATER MAIN WITH A 10" x 6" FL 2 ---------- C x FL TEE. ° C6.40 J� -- -- ----- CONNECT TO EXISTING MANHOLE, � Sp------- =� - 3-��-- - 101L�0�DIP CL 52 SD / / 0 POWE w I /3 =a r 4 RECHANNELIZE STRUCTURE, SEE DETAIL t------------------�-_ - -- -- / N RO K el° N 3 5/C6.8. FOUND 0.5 RBC �- � CO - - - �------- J ' ' N �ALL�- --. �, � SIGN NO A KI „HARSTAD' LS#19731 _ - ... - ... - . . - . - - - - - _ - ' ' - --� - _ _ 2' I �' CONNECT TO BUILDING PLUMBING, SEE AT CORNER • - - - �`��l/ 15.23' \ r - �- , - -, - _ _ �- - - ,- _ _• - - - �G •: _ 4 it°Nl i IIEXISTING 12" WATER 5O MECHANICAL PLAN FOR CONTINUATION. _ •• • __ ( E I$TING WATER C / 6 I I -I • •• SS 0 G1 3 1 � L G .190. 1' OF BUILDING �� �� / � I i � � RICE TO BE 6 SEE DRAINAGE PLAN FOR DRAINAGE DESIGN. FIRE HYDRANT AS EMBLY / F S. N DLO OVERHANG 00 I I r TIR�'P UNDERGROUND POWER, SEE ELECTRICAL I C6.50 1 O -0 3-FOOT DIAMETER I m I 15.00 ER I °( EE DEMO PLAN). O PLAN FOR DETAILS (f� STA:7+87.02, 47' LT /� \ - 06 I� �, �\ 7.50' MP 30 ENTION T 15' ATER EASEMENT I L0 EAS NT 3 CB STD GIRT RIM EL=29.98' z 34LF 6" DIP CL 52 i o \ - IP CL 52 I I �I� I so - s� I + a.a RIM EL W IE-27.33' O GAS SERVICE. w \ 53LF 6" DIP CL 52 - _ - W-6 a o - �b I - C 1 PROFILE 1 Ell D' \ o \ / - - - - „ - - - W-12 N 3 '9O FIRE SPRINKLER SERVICE G C6.20 PROFILE�START \ IP CL 52 g 00 W_7 O 10.00' �84F 10" DIP CL 52 (RJ) 10+0 STD 10� 3 �- I SD21H IM EL=30.56' 0 EL=2 P 1 I52 �_ 4% ,. a... �' E IE=27.18' 10 4-INCH DOMESTIC SERVICE \/ / _ I v W IE=27.16' C6.40 • \ o bk O3 10 31 LF 10" DIP CL - Q \ W-4 ti56 W-5 _ _ _ _ _ _ - _ - - - - / 12LF 6" DIP C 52 �00 _ 18" DI S IE=27.16' _ _ _ d LOCATION OF 18" WATER MAIN ON S GRADY \ \ $k / - - - - 1 LF 6" DIP CL 52 W-10 - - - - - - - - - - 2 W_g J 18' DI N IE=27.11' WAY SHALL BE FIELD VERIFIED BY �3 26LF10"DPCL5 I �° Q r \ I �7.50' 7 50' 4" WATER METER VAUL D 28LF� D- PL 5P 3 , CB CONTRACTOR DURING CONSTRUCTION. IF / 15LF " DIP CL 52 I /2 13 m I I I RIM 11 LOCATION DIFFERS FROM SURVEYED \ f W-11 C6.30 1" DCVA - LOCATION, CONTRACTOR MUST NOTIFY THE / J `-' � 3° IZOFILE 2 E6N S 1W-3 �S E LANDSCAPING ( sL I I 176127.86 CDCCITY AND SUBMIT A DESIGN REVISION PRIOR o JFSTA:9+08.47,15.88'RT 6" DIP CL 2 F SHEET L 3.0 II IIII s IN I I ° 1300805.11 MAIN. v \ / 3 1 TO CONNECTING TO THE EXISTING WATER PI: 7+71.77 \ c - - - A_ I 3 ° PROVIDE VERTICAL CROSS FOR POLYPIG w • \ \ 160 9 5 5 \� PROPOSED ROW i 8 e SDMHFU LL M 12 STATION FOR CLEANING OF WATER MAINS \ CRANE FOUNDATION DEDICATION LINE N I I I BOTTOM S' PER STD. PLAN 300.6 Q I \ 6 PER STRUCTURAL DETECTOR DOUBLE CHECK 1 3 �j \ \ \ • VALVE ASSEMBLY (DDCVA) C6.40 6' - I o G1" IRRIGATION METER �• \ / STA:9+01.47, 16.50' RT 27. - QI TEL. MANHG CONCRETE ENCASEMENT ON SEWER PIPE. LENGTH OF SEWER PIPE TO BE 3I m TEL. POLE & 32" DIA. l 32 �30, \ _ _ _ / 24LF 6" DIP CL 52 I I ( QI GUY ANCHOR GCENTERED AT POINT OF CROSSING SO THAT \ \ J POST INDICATOR VALVE PIV ) DO NOT JOINTS ARE AS FAR AS POSSIBLE FROM THE ( `�0\ • \\r'_, \\ I STA:8+92.38, 25.78' RT C6.70 � � I �I � I ° G � PIPE ENTER SIGN WATER LINE. SIGN I WV W % LEGEND: RIGHT-OF-WAY/PROPERTY LINE 5.0'ROW I s ON sL I CENTERLINE a \, DEDICATION G GAS PIPE a2S•3'. \ PROPOSED I S I I S . /��IGNAL LE S SANITARY PIPE / I°° ° " .a • \\ MULTIFAMILY EXISTING II a//� / /LUMC� W WATER PIPE C6.80 3 \ BUILDING ROW LINE I I'' I S� \ I I 50 .�``'G / /� F FIRE SERVICE PIPING NOTES .. \ 1. MAXIMUM ALLOWABLE °� - \ / = I� I I �/ / //� / o FFE 32.08 p (uc) o Ak FIRE HYDRANT DEFLECTION AT EACH JOINT SHALL \\ .� \ �K NOT EXCEED ONE-HALF THE / 4: j // METER AS NOTED MANUFACTURER'S SPECIFICATION FOR SIZE OF PIPE USED. A° I ° I \ \ 33 W-2 \ 30� 0 50�J J / �/� N GATE VALVE V 1 THRUST BLOCKING PER STD PLANS 330.1 2. ALL WATER FITTINGS AND/ l\ �� I I /o� / /l / C6.30 VALVES WITH MECHANICAL JOINT \ • I \ �\ 50 �`J �, S_MH RIM F�L-30.69 AND 330.2. / \ S I /18'CNC V IE=27.09' FITTINGS AS NOTED (MJ) END(S) SHALL HAVE A �h. J 18" DI --'NE IE=27.09' / WEDGE -TYPE RETAINER GLAND CONNECT TO BUILDING (SEE MECHANICAL FOR CONTINUATION) 0 � `�� 18" NC SW IE-27.09' / EQUAL TO MEGALUG SERIES 1100. PEAK IE: x \ \ IE: 25.17 8" (SW) L� ,� - / / ® PIV HEIGHT / V / a =32't �CTE �I�1�T BLOCKS ARE L \ � � � ��J� // �� \ / '� FDC 3 R afgD ON ALL FITTINGS PER \ \ \\ \ / / I \ jENT CITY OF • C Il��hh UU�� PLANS 330.2 AND 330.3. //� ��,,�\ RENTON CONTROL SANITARY SEWER CLEANOUT C6.80 / POINT ?% ' PROPOSED ,��L8�- ATER MAIN / / \ F� \ ROW DEDICATION /01 \ / J°� �� / / CROSS A NON POTABLE PIPE, ONE LINE % \ / /� FULL LENGTH OF WATER PIPE 6x G� / I ✓ SHALL BE USED WITH THE PIPE / \ �0 5 CENTERED FOR MAXIMUM JOINT - \ \ SEWER PROFILE END C6.80 SEPARATION. _ G 7 5. WATER MAIN TO BE / a a �� \\��� G JB �/ ROWEDICATION CONSTRUCTED FOLLOWING ° ROOF • \ �I • Q� / / /; 5� GEO-PIER INSTALLATION. ° ° IDRAIN \ �� •• / ��JG / �' N f {ITEM 1 }------- ` \ b JGI / W CITY OF RENTON �` // /� CL / CITY UTILITY ESMT. TO CITY / � / \A... SSCO #3 SSCO #2 � JG1� � ® % / �/ o G / /' ; �` \ ORD. 3266 / ND 0. B / e%% �`J J� / /4 / ';� / Gm REC. NO. 7812040685 8" X 6" TEE /�/ w / /SI AL POSE/ > 9 / F` IE: 25.06 8" (NW) • + Al COR R W-2B / j/% / s�. o G N. LINE VACATED SO. 7TH STREET / 2 CB B I IE: 25.06 8" (SE) •�� ��Q � ; , /-___--- " IE: 25.14 6" (NE); J F 0 / ENCLOSURE SHALL BE $ / ® R0.64' ; WOODEN FENCING, PER 3\1 LF 1(�' DIP QL 52 0 � � `�� \ " �IP�W IE 2 �� �F�1 G DETAIL 8 ON SHEET L1.2 P.S.P.L EASEMENT \ J / o SSCO #1 y/ / /� �'� SL 0, CB STD GIRT 7802060578 I RIM EL-29.82 j/ o ° �, / ���Q� / . ° JG PIJG � Pl SEWER CLEANOUT TABLE STRUCTURE NAME STRUCTURE DETAILS RIM = 31.73 SSCO #1 IE = 24.74 (8" NW) IE = 24.74 (8" SW) RIM = 31.67 SSCO #1A IE = 24.45 (8" NE) IE = 24.45 (8" SW) RIM = 31.90 SSCO #2 IE = 25.17 (6" SW) RIM = 31.94 SSCO #3 IE = 25.14 (8" NE) IE = 25.14 (8" SE) WATER STRUCTURE TABLE STATION W # DESCRIPTION STA: 5+00.00, 0.00' CONNECT TO EXISTING WATER MAIN (BY CITY FORCES) PER COR STD PLAN W-1 300.1 1 - 18" X 10" TAPPING TEE (MJ X FL) 1 - 10" TAPPING GATE VALVE (FL X MJ) 1 - THRUST BLOCK STA: 6+44.70, 0.00' W-2 1 - 10" 11.25' BEND (MJ X MJ) 1 - THRUST BLOCK STA: 5+03.00, 0.00' W-2A 1 - 10" 22.50 BEND (MJ X MJ) 1 - THRUST BLOCK STA: 5+35.31, 0.00' W-213 1 - 10" 450 BEND (MJ X MJ) 1 - THRUST BLOCK STA: 7+71.77, 0.00' W-3 1 - 10" 900 BEND (MJ X MJ) 1 - THRUST BLOCK STA: 7+87.02, 0.00' 1 - 10" X 6" TEE (FL X FL) W-4 1 - 6" GATE VALVE (FL X MJ) 1 - 10" GATE VALVE (FL X MJ) 1 - 10" ADAPTER (FL X MJ) 1 - THRUST BLOCK STA: 8+12.97, 0.00' W-5 1- 10" 11.25' BEND (MJ X MJ) 1 - THRUST BLOCK STA: 9+01.47, 0.00' LT 1 - 10" X 6" TEE (FL X FL) W-6 1 - 6" GATE VALVE (F L X MJ) 1 - 10" GATE VALVE (F LX MJ) 1 - 10" FL X MJ ADAPTER 1 - THRUST BLOCK STA: 9+08.47, 0.00' RT 1 - 10" X 6" TEE (FL XFL) W-7 1 - 6" GATE VALVE (F L X MJ) 1 - 10" GATE VALVE (F L X MJ) 1 - 10" FL X MJ ADAPTER 1 - THRUST BLOCK STA: 10+63.73, 0.00' RT CONNECT TO EXISTING WATER MAIN CUT IN TEE (BY CITY FORCES) PER COR STD PLAN 300.4 W-8 1 - 12" X 10" TEE (FL X FL) 1 - 10" GATE VALVE (FL X MJ) 2 - 12" GATE VALVE (FL X MJ) 2 - 12" SOLID SLEEVES (MJ) 1 - 10" SOLID SLEEVE (MJ) 1 - THRUST BLOCK STA: 5+00.10, -9.74' LT CONNECT TO EXISTING WATERMAIN BY CITY FORCES WITH CUT IN TEE & ONE W-9 VALVE PER STD PLAN 300.1 1 - 18" X 6" TEE (FL X FL) 2 - 18" ADAPTERS (FL X MJ) 1 - 6" GATE VALVE (FL X MJ) 1 - THRUST BLOCK STA: 9+08.47, 12.00' RT W-10 1 - 6" X 4" REDUCER (MJ X FL) STA: 9+08.47, 19.75' RT W-11 1 - 6" X 4" REDUCER (MJ X FL) STA: 10+24.63, 0.00' W-12 1 - 3" WET TAP PER COR STD PLAN 300.1 1 - THRUST BLOCK 2 Ln Ir- C6.40 r O 0 N u 1►�'1 H H r Q J r 2 N C6.50 W 420001 U) 0 Ns A TqA IN COMPLIANCE WITH CITY OF RENTON STANDARDS z SEWER PR��IL §fARI. °. ���jNc� � o LU C6.8 8 SW 1 0.98' �F�RENT0 5X� N 17587j I RNG 5E] y/ G/ / / / � � / / / t� CC CB STD GIRT � F COMMENCF,MENT / / / G / / DEVELOPMENT ENGINEERING G N o"I EwALK. TR�FFC E 1 99 P CEL C JChavez 07/27/2022 Q` RIM EL=30.7�� 0 / / �� SIGNALS A STREET / k C� STD/�T / - CR8"CNC SE IE-2 Gl IGHT EMENT. / ` �° � i "Z 35702 S�I IF) / , / / °. ° IM EL=31 S5 / G� / ��rtISTER'° AO. 871022135 G Y ANC W I1-29.43' RIM EL=30.9 '�� / / gTE TO�EINE / \ ANAL CITY OF RENTON / / / s / S'I 30.0' UTILITY ESMT. TO CITY - TnIOT "CNCT( IE=2^.^k�� /� �G 1 / / /G /% �o G // � / - ✓ / ORD. 3286 w Know what's below. z Call before you dig. J 8"CNC N IE-26.22' T F ER PAD / > SSCO #1A w� sL 1F., 8"CNC S IE=26.12' / ELEC F�ICAL PLAN / G / J� ,��° ��?�� /G / ° SIGNAL/ 50 8"GONG TOP VERT IE-26.62' P r - P - v W-2A ��/ \S �G / X �o // S-420001 BTM STRUC. IE-25.42' / (u P(up 0 / S EXI G 18" WAT`A r L qY . / JBOX 3LF 10" DIP CL 5 �3.00 , /,: POL /f 4) PARCEL / PARCEL D �`' / °��ti / / / Q`o w w `J 2 11 12 // \ 0S / /G ; - ° GU SSMH RI EL W30.8 / W-9 IG �`JG� / .5" ASSIE W/PUNCyi\As�i' G , ' l N( HOR ,F� ��� / PROFILE �, DOVAN 0. [S€ �OR-SEC. 18, GRAPHIC SCALE 0 10 20 40 1" = 20 FEET J / 1/ i G /� -o.f / /// y° sib' I //ZIA\ - 1 ` 07/26/2022 Gwl Engineers 1 PERMIT REVISION JN 3/18/22 DT SURVEYED: SCALE =1 - SI-1111lEngmeers T.L. VERTICAL W4VD 1988 • 2 PERMIT REVISION JN 4/25/22 DT PER SHEET HORIZONTAL' WAD 1083/1091 CITY OF and eaPea nira DESIGNED: CommurxlyPlanners 3 PERMIT REVISION JN 5/12/22 DT J.N. RENTON land8uHj rveyas Dom' = J.N. Neighbors ONE INCH DATUM • CHECKED: AT FULL SCALE Planning/Building/Public Works De t T A C O M A • S E A T T L E DT IF NOT ONE INCH p' 2215 North 301h Street, Suite 300, Tacoma, WA 98403 253.383.2422 TEL SCALE ACCORDINGLY 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 206.267.2425 TEL NO. REVISION BY DATE AP P R APPROVED: WATERSHED APARTMENTS CIVIL CONSTRUCTION PERMIT UTILITY PLAN a Q LU DATE: 03/18/2022 = FIELDBOOK: U) PAGE: Ir DRAWING NO: C6.00 LU F- Q SHEEP: 1 Q OF: 46