Loading...
HomeMy WebLinkAboutS-420003V ) Z CW G I- rr a n Q LU r2 /V�J� LL W a L;j a Z J lL BDLTHOLES - 3 PLCS EQUALLY SPACED 120" APART ON 23 1/16' (586mm) DIA BC (SEE DETAIL) COVER & FRAME PLAN VIEW 25' DIA [635mm] 1" 3/4'25mm7 C19mm7 8 3/4' 2 1/2' [222mm] 164mm] TYP COVER SECTION VIEW 26 112' DIA E673mm] 25 1/4' DIA [641mm] 1 1/16' 1/4' (6mm) DIA [27mm7 NEOPRENE GASKET 6" [15f mm] 5/8' 23 3/8' DIA CL OPEN C16mm] C594mm] 27 5/16' DIA C694mm] 34 1/8' DIA COVER BOTTOM VIEW 3) BLT S❑C (ALLEN HEAD) 5/8'-11 X 15 SS \ RUBBER WASHER BOLTING DETAIL 1/4' [6mm] 1 1/16' [27mm3 1/8' C3mm] CR3mm] GASKET GROOVE DETAIL [B67mm) NOTES FRAME SECTION VIEW 1 ALL FRAME AND COVER ASSEMBLIES SHALL HAVE A LOCKING LID PER EAST JORDAN IRON WORKS INC PRODUCT No 00371572 OR EQUAL. 2 USE FRAME AND COVER FOR SANITARY (SPECIFY "SEWER") STD. PLAN - 401.1 URI PUBLIC WORKS SEWER MANHOLE FRAME AND COVER DEPARTMENT (CITY -OWNED) Martin PastucNa-1 zoz ,,1,}{Ik3449U.. DATE SEWER MANHOLE FRAME AND COVER W (SEE NOTE 7) BEDDING MATERIAL FOR SANITARY SEWER PIPE (SEE NOTE 5) -� FOUNDATION LEVEL LIMITS OF PIPE ZONE O.D. of PIPE BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS 5 PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3) OF THE STANDARD SPECIFICATIONS 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED 7 TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. STD. PLAN - 405 VRI PUBLIC WORKS PIPE BEDDING A'P "° DEPARTMENT FOR SANITARY SEWERS Martin PastuCha/26/202 n„eu. w"..*Rp[A�FlJ9H13449L) DATE NOT TO SCALE �` J NOT TO SCALE QjR Know what's below. Call before you dig. CONNECT TO MECHANICAL PER PLUMBING 30 25 22 r C� w SSCO #3 N: 175923.46 E: 1300644.07 RIM: 31.94 IE IN: 25.14 (8"NE) IE OUT: 25.14 (8"SE) SSCO #1 N: 175906.52 E: 1300654.93 RIM: 31.73 IE IN: 24.74 (8"NW) IE OUT: 24.74 (8"SW) SSCO #1A N: 175895.01 E: 1300646.15 RIM: 31.67 IE IN: 24.45 (8"NE) IE OUT: 24.45 (8"SW) SOUTH PROPERTY WEST LINE EX SEWER MANHOLE N: 175873.92 E: 1300602.94 RIM: 30.83 IE IN: 23.49 (8"NE) USE INSIDE DROP CONNECTION IE OUT: 20.98 (8"SW) 35 ,1EM ME �1 I 1 ' - AMEN m • 0) II �■■SENSE on 30 MANHOLE CONNECTION SHALL BE CORE DRILLED. USE CORE N SEAL CONNECTORS OR APPROVED EQUAL. 25 22 CD H 0+00 0+50 0+94.12 FINISHED GRADE AT SEWER CENTER LINE EXISTING GRADE AT SEWER CENTER LINE SEWER PROFILE SCALE: 1" = 20' (H) 1" = 10' (V) 0511212022 �� �� • Civil Engineers sln,�nalEngineers Landscape A,chltecls 1 PERMIT REVISION 2 PERMIT REVISION 3 PERMIT REVISION Community Planners O Land Surveyors (a oil Ne ighbors T A C O M A • S E A T T L E 2215 North 30th Street, Suite 300, Tacoma, WA 98403 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 253.383,2422 TEL 206.267.2425 TEL N 0 REVISION DSEWER'S RECESSED LIFT POCKET 3/4" LETTERING "SEWER" (2) BOLT SOC. (ALLEN HEAD) 5/8" - 11 X 1 5 STAINLESS STEEL REF PART #00981177 I I 1-3/16" 5/I _T1-1/g„ 2-1/4" 1213/4"�� CAST IRON RING AND COVER Not to Scale FRAME 1 r-nr' Ill ALIT Trf'� 1 r_nr. 45' (1/8) BEND OR DABLE PIPE MATERIAL AS SPECIFIED BY THE ENGINEER NOTES. 1 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC No 3698 (PRODUCT NO 00369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY 2 IN UNIMPROVED AREAS, POUR A 8" THICK, 3'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER 3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106 STD. PLAN - 403.1 PUBLIC WORKS 8" OR 6" CLEANOUT ne Y DEPARTMENT FOR SANITARY SEWER MAIN Martin PastuCtij/26/2020 M 9D DATE SANITARY SEWER CLEANOUT NOT TO SCALE JN 3/18/22 DT SURVEYED: T.L. JN 4/25/22 DT DESIGNED: J.N. JN 5/12/22 DT DRAWN: J.N. CHECKED: DT BY DATE AP P R APPROVED: r--1-r---------- �� EX. SEWER MAIN l PROPERTY LINE SPOOL I I I Z (LENGTH AS NEEDED) i S-O" MIN 6" SEWER STUB i i �:+ FUTURE 4" SIDE SEWER I I ` 2"x 4" STUD MARKING POST PAINTED TiORD "SEWER" STENCILED SEWER MAIN TEE X 6" TEE i i i i I IN 3" HIGH BLACK LETTERS AND #6 WIRE SIDEWALK i z WRAPPED AROUND THE STUD AND `\ I I I I J EXTENDED TO THE TOP OF THE STUD ` COUPLING TYP I I I i ( ) L_J_L---------� a 13 I 5"X6"X6" SURFACE CLEANOUT WITH CAST IRON RING AND COVER O (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR 1 4 APPROVED EQUAL, SPECIFY "SEWER" ON LID), CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD CONCRETE PAD TO BE 8" IN DEPTH --------------T-J r-____--_-i. L-__J BEND AS 8" REQUIRED EXISTING SANITARY _ SEWER MAIN r2 07, MIN SLOPE 3 FUTURE 4" SIDE SEWER \\-6" SEWER STUB 6"X6"X6" WYE FUTURE 6"x 4" REDUCER SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL) C PVC & C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED NTH A ROMAC SADDLE (OR APPROVED EQUAL) D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F HOPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL NOTES. 1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2 5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHALL HAVE A MINIMUM 2 7 SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 110 2 6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405 7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON SIDE SEWER STUB STD. PLAN -406.1 PUBLIC WORKS APP INSTALLATION URI DEPARTN Martin PastuChOV26/202 (SEWER MAIN TO PROPERTY LINE) 8E38k8J FD98844u J - rom,c w"rw, ,wmmi"r.m, DATE SIDE SEWER CONNECTION NOT TO SCALE LO T L^T O (D N * , u T a J T n S-420003 IU) IN COMPLIANCE WITH CITY OF RENTON STANDARDS ~ Z CW EJl ELOPMENT ENGINEERING G .+ havezz 05/17/2022 Q n Q 0 SCALE: DATE W VERTICAL: 1 1988 PER SHEET HORIZONTAL 1 1983/1991 WATERSHED APARTMENTS 03/18/2022 = ® CITY OF CIVIL CONSTRUCTION PERMIT U) ('.*" IRENTON FlELDBOOK: fr PAGE vul• DRAWING NO: W ONE INCH DATUM AT FULL SCALE Planning/Building/Public Works Dept. PUBLIC SEWER DETAILS IF NOT ONE INCH C6.80 SCALE ACCORDINGLY SHEET: OF: 26 46