Loading...
HomeMy WebLinkAboutS-420003• • CV r.' ►740 ONE V ) Z W 75 Q n 0 Uj V rr2 JJ rr ui 6mi a Z W w BOLTHOLES - 3 PLCS EQUALLY SPACED 120" APART ON 23 1/16' (5861 DIA BC (SEE DETAIL) COVER & FRAME PLAN VIEW 25' DIA C6351111] 1' 3/4'251 C19r1r17 8 3/4' 2 1/2' C222mml 164mml TYP COVER SECTION VIEW 26 112' DIA [67311r1] 25 1/4' DIA C64111r1] 1 1/16' 1/4' (61m1) DIA C27ror1] NEOPRENE GASKET 6. 1 7t C15' 2 roro] 5/8" 23 3/8' DIA CL ❑PEN C16ro11] [594rm1] 27 5/16' DIA [694mm] 34 1/8' DIA COVER BOTTOM VIEW (3) BLT SOC (ALLEN HEAD) 5/8'-11 X 15 SS RUBBER WASHER ALL BOLTING DETAIL 1/4' 1 1/16' C 61111] C27MM] 1/8' Minn] [R3nr1] GASKET GROOVE DETAIL [8671 NOTES FRAME SECTION VIEW 1 ALL FRAME AND COVER ASSEMBLIES SHALL HAVE A LOCKING LID PER EAST JORDAN IRON WORKS INC PRODUCT No 00371572 OR EQUAL. 2 USE FRAME AND COVER FOR SANITARY (SPECIFY "SFWFR") STD. PLAN - 401.1 PUBLIC WORKS SEWER MANHOLE FRAME AND COVER Ei1. 19nedby VRIDEPARTMENT (CITY -OWNED) Martin PastucunaIj z iLkIU449u DATE SEWER MANHOLE FRAME AND COVER W (SEE NOTE 7) BEDDING MATERIAL FOR SANITARY SEWER PIPE (SEE NOTE 5) FOUNDATION LEVEL LIMITS OF PIPE ZONE MIN O.D. of PIPE BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS 5 PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3) OF THE STANDARD SPECIFICATIONS 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED 7 TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. STD. PLAN - 405 URIPUBLIC WORKS PIPE BEDDING APP DEPARTMENT FOR SANITARY SEWERS Martin Pastucha 26/202c v„or, wan. n­fflWWamF Uy8�3449U DATE NOT TO SCALE ` L I NOT TO SCALE Know what's belOW. Call before you dig. CONNECT TO MECHANICAL PER PLUMBING 35 30 25 22 C� w SSCO #3 N: 175923.46 E: 1300644.07 RIM: 31.94 IE IN: 25.14 (8"NE) IE OUT: 25.14 (8"SE) SSCO #1 N: 175906.52 E: 1300654.93 RIM: 31.73 IE IN: 24.94 (8"NW) IE OUT: 24.94 (8"SW) SSCO #1A N: 175895.01 E: 1300646.15 RIM: 31.67 IE IN: 24.45 (8"NE) IE OUT: 24.45 (8"SW) SOUTH PROPERTY WEST LINE EX SEWER MANHOLE N: 175873.92 E: 1300602.94 RIM: 30.83 IE IN: 23.49 (8"NE) USE INSIDE DROP CONNECTION IE OUT: 20.98 (8"SW) 35 .�■M 30 MANHOLE CONNECTION SHALL BE CORE DRILLED. USE CORE N SEAL CONNECTORS OR APPROVED EQUAL. 25 22 C7 LL 0+00 0+50 0+94.12 FINISHED GRADE AT SEWER CENTER LINE EXISTING GRADE AT SEWER CENTER LINE SEWER PROFILE SCALE: 1" = 20' (H) 1"=10'(V) RECESSED LIFT POCKET 3/4" LETTERING "SEWER" (2) BOLT SOC. (ALLEN HEAD) 5/8" - 11 X 1 5 STAINLESS STEEL REF PART #00981177 �---� 1 -3/16" -1 O-1/2"-�{ 5/I 1/4,,,2-1/2"ill 2-1/4" 14" �I CAST IRON RING AND COVER Not to Scale FRAME 1'-(1 ninurTrn 1 -(1" 45• (1/8) BEND OR DABLE PIPE MATERIAL AS SPECIFIED BY THE ENGINEER NOTES. 1 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC No 3698 (PRODUCT NO 00369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY 2 IN UNIMPROVED AREAS, POUR A 8" THICK, 3'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER 3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106 STD. PLAN - 403.1 . i PUBLIC WORKS 8" OR 6" CLEANOUT nI,d by DEPARTMENT FOR SANITARY SEWER MAIN Martin Pastuclia/26/2020 'VQ=,,VM49D DATE SANITARY SEWER CLEANOUT NOT TO SCALE !' OP �y"SST OA F TCASgINC�tS1 f?f °•p 46416sv� O GISTERE9 IONAL will d" Civil Engineers strucrwarEnglneers ede��A,°n;re°rs °rsmuniyFlanners Q [no O °°°S° ey°rs "eighb°rs TACO MA • S EATTLE 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422 TEL 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 206.267.2425 TEL 001 ASI-001 CJ 9/27/22 DT SURVEY D' T.L. SCALE: PER SHEET HOR O VERTICAL I•AL• N i 19aa 991 DATUM 002 PROGRESSIVE CONSTRUCTION SET CJ 12/5/22 DT DESIGNED: J.N. 003 UPDATES PER CONDITIONS OF APPROVAL DT 1/27/23 DT 004 GRADY WAY STORMWATER REVISIONS CW 12/26/23 TS D� J.N. ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 005 AS -BUILT REVISIONS AA 03 /26/241 TS CHECKED: DT N 0. REVISION BY DATE AP P R APPROVED: r--i-r---------- �� EX. SEWER MAIN I I I I i i I PROPERTY LINE -SPOOL I 1 I ? (LENGTH AS NEEDED) i 3'-0" MIN 6" SEWER STUB ,' FUTURE 4" SIDE SEWER \ 2"x 4" STUD MARKING POST PAINTED t I I I 6" CAP JJJ WHITE WITH THE WORD "SEWER" STENCILED `SEWER MAIN TEE X 6" TEE i i i i I IN 3" HIGH BLACK LETTERS AND #6 WIRE SIDEWALK i . z WRAPPED AROUND THE STUD AND I I I I _1 EXTENDED TO THE TOP OF THE STUD COUPLING TYP I I I L_J_L_________J G ( ) e>.� 13 � 1SURFACE CLEANOUT WITH CAST IRON RING AND COVER 10 I (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR 1- APPROVED EQUAL, SPECIFY "SEWER" ON LID), 9 CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD CONCRETE PAD TO BE 8" IN DEPTH r r---- ----- 1 ----------------------r-J r----- ---- -„. L---J BEND AS g" REQUIRED EXISTING SANITARY _ SEWER MAIN r---2 OR MIN SLOPE ]3 \ FUTURE 4" SIDE SEWER "6" SEWER STUB 6"X6"X6" WYE FUTURE 6"x 4" REDUCER `SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL) C PVC do C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F HDPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL NOTES- 1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 25' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHALL HAVE A MINIMUM 2 % SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102 6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405 7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON SIDE SEWER STUB STD. PLAN-ao6.1 PUBLIC WORKS APP r INSTALLATION DEPARTMENT Martin PastUCl�@y26/202 (SEWER MAIN TO PROPERTY LINE) Pb<t�3T U98"64a9D - DATE SIDE SEWER CONNECTION NOT TO SCALE RECORD NOTE 03/26/2024 THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON SURVEY INFORMATION PROVIDED BY A THIRD -PARTY SURVEYOR. AHBL WILL BE RESPONSIBLE FOR THE DATA PROVIDED BY THEM. THE THIRD -PARTY SURVEYOR WILL BE RESPONSIBLE FOR THE ACCURACY OF THE ACTUAL LOCATIONS IN THE FIELD. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. CITY OF RENTON (D Planning/Building/Public Works Dept. U T Ir n S-420003 I� IN COMPLIANCE WITH CITY OF RENTON STANDARDS 7 WATERSHED APARTMENTS CONSTRUCTION DRAFT SET PUBLIC SEWER DETAILS W G Q IZ a 0 LLI = DATE: 03/28/2023 MU DBOOK: PAGE: Uj � DRAWING NO: C6.80 a SHEEE: OF. 26 48