HomeMy WebLinkAboutzS-4200Set1/ 1 ' � W \' I I / 3 .. \ FOUND 0.5" RBC I KEYNOTES "HARSTAD" LS#19731 l �I AT CORNER i �' I 3 ° ° O PROPOSED HYDRANT ASSEMBLY PER COR j\ Q a I I CONC. STD PLN. 310.1. r_,P� FIRE DEPARTMENT , HEIGHT HORIZONTAL DEFLECTIONS AS NECESSARY �PEAK� t WALL I j I °4 .° O CONNECT TO WATER MAIN WITH CUT -IN TEE C6. CONNECTION (FDC) =29't PEP/ � L(l//1L7/ �/111/�NS /t t � I I 3 AND THREE VALVES, PER STD PLAN 300.4. yt � j SS(REFg� � .. ° TEL. STA:7+89.12, 40.72' LT • °/ / ///// /1L// % /11z/ IPOLE 3 CONNECT TO WATER MAIN WITH A 10" x 6" FL 2 �� II I 0 x FL TEE. C6.40 0------- --j -- I I j ° I / /� / POWE NELIZE STRUCTURE, SEE DETAIL ----------- ------ ----------- 101L_ DIP CL 52 SID RECHAN ------- -_ _-0__ _______ / N P�� r� CONNECT T EXISTING MANHOLE, FOUND 0.5",RBC \� 1 CO 1 J `" - WALL NO PA KI aNl I I�i' 4 E, S 3 I \ 5/C6.8. "HARSTAD' LS# 19731 - - - ... - . _ ' ' SIGN , e AT CORNER . I GNP 1 I CONNECT TO BUILDING PLUMBING, SEE 15.23 \ - XISTING 12 WATER MECHANICAL PLAN FOR CONTINUATION. ' 6 •• •n /•' • i I SS 0(G1� E WING WATER O6 SEE DRAINAGE PLAN FOR DRAINAGE DESIGN. 1 S. (IN 190 K OF BUILDING I RVICE TO BE FIRE HYDRANT AS EMBLY F F C6.50 O o 3-FOOT DIAMETE� N I OVERHANG 1 f - TIRED UNDERGROUND POWER, SEE ELECTRICAL (n STA:RANT 2, iVI LT \ 1 AS ER I 1 �, I � 7 °( EE DEMO PLAN). PLAN FOR DETAILS CMP DETENTION 15' WATER EASEMENT + AS NT I I I I 13 CB STD CRT \ 7.50' 1 k RIM EL=29.98' z 34LF 6" DIP CL 52 \ ' I a 7LF �" DIP CL 52 I �' I Ilp N I + O8 GAS SERVICE. LL] \ c9� -53LF 6_DIP CL 52 - - - W-6- - - ° ■ I ISD - D - D _ � _ a. O',I 12"ADS W IE=27.33' C �p \ - - - - W-12 I 3 O FIRE SPRINKLER SERVICE C C6 20 PROFILE I 2ESTART \ \\ 88LF 10" DIP CL 52 9 00 W-7 O 10.00, 84LF 10 DIP CL 52 (RJ) B STD a I SDMH RIM EL=30.56' 3 \ 10+4 FI =2 - -,34L DIP CL 12"ADS E IE=27.18' 10 4-INCH DOMESTIC SERVICE r • \ 3 c 2 12" DI W IE=27.16' Q----------- 0-- 10 31LF10" IPCL 1. ° I C6.40 W 4 W-5 12LF 6" DI CL 52 8?00' _ C6.. 0 8" DI S IE=27.16' LOCATION OF 18" WATER MAIN ON S GRADY " -�`�- ---- a / '�-- ° 18" DI N IE=27.11' \ 8k i - - - - 12LF 6 DIP CL 52 W-10 M - - - - - 2 W-8 a WAY SHALL BE FIELD VERIFIED BY 1 26LF10"DPCL5 r ----- 1 J -�-�- Q 7 50' 7 50 I �� n U 28L DO L 50 3 CONTRACTOR DURING CONSTRUCTION. IF CB \ 4" WATER METER VAUL 2 13 - m U I LOCATION DIFFERS FROM SURVEYED 0 i 15LF " DIP CL 521W-11 STA:9+08.47, 15.88' RT J I I RIM 11 LLI v \ i C6.30 1" DC J 0 3 �2OFILE 2 FBN S I LOCATION, CONTRACTOR MUST NOTIFY THE W-3 SEE LANDSCAPING - SL I 176127.86 C C CITY AND SUBMIT A DESIGN REVISION PRIOR v \ \ OLF 6" DIP CL a • �� I o 1 TO CONNECTING TO THE EXISTING WATER - SHEET L 3.0 II 0 1300805.11 1 \ \ i �� ° rr PI: 7+71.77 \ ry \ � L - - - I � I ° MAIN. ", 1 9 5 LL G f SDMH RIM PROVIDE VERTICAL CROSS FOR POLYPIG LU • PROPOSED ROW I 8 I =FUL\i DEDICATION LINE I I I BOTTOMLS 12 PER STD. POLAN 300.61NG OF WATER MAINS N Q I \\ 6 CRANE FOUNDATION 5 DETECTOR DOUBLE CHECK 1 T I I 3 I� 13 1" IRRIGATION METER \ \ PER STRUCTURAL VALVE ASSEMBLY (DDCVA) C6.40 = 6' v I i 0 \ �� �• C6 70 POST INDICATOR VALVE (PIV) 0 / STA:9+01.47, 16.50' RT Q27. 6' Iv I I I TEL. MDANAHOI CONCRETE ENCASEMENT ON SEWER \ \ STA: / \ \ / 24LF 6" DIP CL 52 I I I w3 m ;.� PIPE. LENGTH OF SEWER PIPE TO BE 3 7+28.38, 26.06' RT / TEL. POLE & J I al � _ •: �GUY ANCHOR 14 CENTERED AT POINT OF CROSSING SO THAT ° DO NOT JOINTS ARE AS FAR AS POSSIBLE FROM THE • \ I � I I �, WATER LINE. \ � a N a •�' ENTER SIGN • \ I F G L� PIPE / N W I IGIN / LEGEND: - - RIGHT-OF-WAY/PROPERTY LINE A. �I �. \ k\ I I I ' J $L < • �, � \ oo �, 5.0i ROW � I _ s CENTERLINE ° ' A \\ 10 DEDICATION � o I � � G GAS PIPE \ I Io��o SIGNAL LE S SANITARY PIPE 2 25.3' . ' \ 3 a \ \ PROPOSED S s w/ LUMfN�' c6.8o ° ° "•a • \ \ MULTIFAMILY EXISTING I I / / W WATER PIPE NOTES / •I\' \ \ ROW LINE II a I I I I �� / /�`� I•.• °�. ° \ \ BUILDING I I s� \ N I .�/� / F FIRE SERVICE PIPING 1. MAXIMUM ALLOWABLE - I I DEFLECTION AT EACH JOINT SHALL / \ ,� ,3 FFE-32.08 J®X (uc) \ \ o / ,G� r� Ak FIRE HYDRANT CCii .ac NOT EXCEED ONE-HALF THE / : Q1 \\ • \ \ I \ j // // METER AS NOTED MANUFACTURERS SPECIFICATION FOR SIZE OF PIPE USED. ° I'". 1 \ 3 \ W-2 �3p I N �J J /�\ �/� N GATE VALVE • THRUST BLOCKING PER STD PLANS 330.1 2. ALL WATER FITTINGS AND \ I� AND 330.2. C6.30 VALVES WITH MECHANICAL JOINT \ • \ \ \ I �o � C, H RIM �,L=30.69' (MJ) END(S) SHALL HAVE A / 0�� \ \\ gyp\ ` I /18 CNC�IyE IE=27.09' � y--[ C �C FITTINGS AS NOTED f/j7T/ CONNECT TO BUILDING (SEE MECHANICAL FOR CONTINUATION) ` �,� 18 DI NE IE=27.09' WEDGE -TYPE RETAINER GLAND EQUAL TO MEGALUG SERIES 1100. HEIGHT " \\ \ \ IE: 25.17 8" (SW) � PIV /X 18"ANC SW IE=27.09' / /�/ � ® =32'f - \ �KI � / I �" " W / � FDC 3. CONCRETE THRUST BLOCKS ARE \ \ REQUIRED ON ALL FITTINGS PER HELD CIT� OF • SANITARY SEWER CLEANOUT 3 COR STD PLANS 330.2 AND 330.3. /� , \ \\ / �, I //RENTO1 CONTROL C6.80 PROPOSED / 7y\ POINT 0393 14. WHERE NEW WATER MAIN / \, \ j / �1 , y�\� ROW DEDICATION I CROSS A NON -POTABLE PIPE, ONE /� \ \ LINE j // //� PF� I 9i'lro FULL LENGTH OF WATER PIPE 6X \ G� / _ J I ✓ SHALL BE USED WITH THE PIPE o o�� G� / h✓,, CENTERED FOR MAXIMUM JOINT / / - \\ 9�,� \ \ SEWER PROFILE END C6.80 O ��� j SEPARATION. / , \ 5. WATER MAIN TO BE ° �i it 7 5.4' / \ C� \ \\ % / / JB / o ROW/ bEDICATION /, Q CONSTRUCTED FOLLOWING /� 1 ROOF • \ M ��, • / Q Q�` / IL / / 5�0 GEO-PIER INSTALLATION. :aQ 1 DRAIN I _ \ •• % / ��oG / / �` I //;� %OF €ITEM 1} \ ------- ------I \ �C"�' ��i�o`, /���/ / o �, •� `� j 4L CITY OF RENTON 30.0' UTILITY ESMT. TO CITY CB STD CRT \ SSCO #3 SSCO #2 JG�� ORD. 3266 RIM EL=30.90, i \ UND 0. RBC / Q%� REC. NO. 7812040685 / 24"CNC NE IE / / ��o o' , i <" 8 X6"TEE <`' // / 1 24"CNC SW IE AT COR / QSI AL POLE IE: 25.06 8" (NW) • + W-2B N. LINE VACATED SO. 7TH STREET /� I IE: 25.06 8" (SE) \ \ 1 C 2 �� CB IE: 25°%--__--- TRANSFORMER ENCLOSURE PER .14 6" (NE), - o R 64 �� 31LF 10 DIP L ' ��/ ��\ �1 `' ARCHITECTURAL DETAILS �W IE-2 F SSCO #1 sL CB STD GRT �� RIM EL=29.82' ' \ P I �/ / / 5��\ej / ; PIuG el . CITY OF RENTON 30.0' UTILITY ESMT. TO CITY ORD. 3286 w Know what's beIOW. Z Call before you dig. WATER STRUCTURE TABLE STATION W # DESCRIPTION STA: 5+00.00, 0.00' CONNECT TO EXISTING WATER MAIN (BY CITY FORCES) PER COR STD PLAN W-1 300.1 1 - 18" X 10" TAPPING TEE (MJ X FL) 1 - 10" TAPPING GATE VALVE (FL X MJ) 1 -THRUST BLOCK STA: 6+44.70, 0.00' W-2 1 - 10" 11.25' BEND (MJ X MJ) 1 -THRUST BLOCK STA: 5+03.00, 0.00' W-2A 1 - 10" 22.5° BEND (MJ X MJ) 1 -THRUST BLOCK STA: 5+35.31, 0.00' W-213 1 - 10" 45' BEND (MJ X MJ) 1 -THRUST BLOCK STA: 7+71.77, 0.00' W-3 1 - 10" 90° BEND (MJ X MJ) 1 -THRUST BLOCK STA: 7+87.02, 0.00' 1 - 10" X 6" TEE (FL X FL) W 4 1 - 6" GATE VALVE (FL X MJ) 1 - 10" GATE VALVE (FL X MJ) 1 - 10" ADAPTER (FL X MJ) 1 -THRUST BLOCK STA: 8+12.97, 0.00' W-5 1- 10" 11.25' BEND (MJ X MJ) 1 -THRUST BLOCK STA: 9+01.47, 0.00' LT 1 - 10" X 6" TEE (FL X FL) W 6 1- 6" GATE VALVE (F L X MJ) 1 - 10" GATE VALVE (F LX MJ) 1 - 10" FL X MJ ADAPTER 1 -THRUST BLOCK STA: 9+08.47, 0.00' RT 1 - 10" X 6" TEE (FL XFL) W-7 1 - 6" GATE VALVE (F L X MJ) 1 - 10" GATE VALVE (F L X MJ) 1 - 10" FL X MJ ADAPTER 1 -THRUST BLOCK STA: 10+63.70, 0.00' RT CONNECT TO EXISTING WATER MAIN CUT IN TEE (BY CITY FORCES) PER COR STD PLAN 300.4 W 8 1- 12" X 10" TEE (FL X FL) 1 - 10" GATE VALVE (FL X MJ) 2 - 12" GATE VALVE (FL X MJ) 2 - 12" SOLID SLEEVES (MJ) 1 - 10" SOLID SLEEVE (MJ) 1 -THRUST BLOCK STA: 5+00.10, -9.74' LT CONNECT TO EXISTING WATERMAIN W-9 BY CITY FORCES PER STD PLAN 300.1 1 - 18" X 6" TAPPING TEE (MJ X FL) 1 - 6" TAPPING GATE VALVE (FL X MJ) 1 -THRUST BLOCK STA: 9+08.47, 12.00' RT W-10 1 - 6" X 4" REDUCER (MJ X FL) STA: 9+08.47, 19.75' RT W-11 1 - 6" X 4" REDUCER (MJ X FL) STA: 10+24.63, 0.00' 1 - 3" WET TAP PER COR STD PLAN 300.1 W-12 1-10" 45' VERTICAL BEND (RJ X RJ) 1 - VERTICAL CONCRETE DEAD -MAN THRUST BLOCK RECORD NOTE 03/26/2024 THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON SURVEY INFORMATION PROVIDED BY A THIRD -PARTY SURVEYOR. AHBL WILL BE RESPONSIBLE FOR THE DATA PROVIDED BY THEM. THE THIRD -PARTY SURVEYOR WILL BE RESPONSIBLE FOR THE ACCURACY OF THE ACTUAL LOCATIONS IN THE FIELD. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN 8"CNC N IE=26.22' SSCO #1A W SL �F,, eNGI INDEPENDENT VERIFICATION OF ITS ACCURACY 8"CNC S IE=26.12' / E IC�AL7YCAN57 ��IG / �� ��\ `'�' ° SIGNAL/ o BEFORE APPLYING IT FOR ANY PURPOSE. /s / 8"CONC TOP VERT IE-26.62' VAULT�� / iG /� o ��'�/ / X o //�/ S-420001 BTM STRUC. IE=25.42' / , PN PN�j 0 P u J W-2A Q �` / '� S �STo EXI G 18" WAl`�rR �' l Y : ' / BOX 1 --- -- --- POL f // z GRAPHIC SCALE 0 10 20 40 1" = 20 FEET P.O.B 3 C` L 5 PARCEL D e`G w w s `J, 2 11 12 0 ,4 � soFS / / G ° GU / /5 / , �S���ST OP�LG' SSMH RI EL W30.8 / W-9 �J��� / 2.5" ASSIE W/PUNC�i�Aso G, NCHOR o �� `� / PROFILE 1 DOVAN 0 [SE-COR-SEC. 18, SEWER PRO01LE fAR e1° IP CL 52 8 S 1 0.98' N 17587�k, I I . 5E] // G / C6.8 /CB STD T �6F RENTON F COMMENCFME4 / / / oG�" EWALK. TRAFFIC E 1 .99 P CEL C //� Q` RIM EL= 0.7f�� /' 0 / 44 SIGNALS AND STREET / � � / C ST CKT Ln 2 r LO C6.40 r O O T Q J T 2 N C6.50 VV'�FGVVV I (/) IN COMPLIANCE WITH CITY OF RENTON STANDARDS 7 �8 CNC SE I 2 1 G) ` / GHT EASEMENT. / G / �° i ; i / �o 46416 9 �nl I� I �� / i / °. o IM ,EL=31-55 / cc +� �CISTERE `oar �` /// N0. 8710221353 , / �( 8%CNC W 129.43' \ �ssl RIM EL-30. / / � / TE TO I E / ANAL -rlurl "CNCT( IE=2^.^��� 1 / / / .yo. / 1 / 1 / Civil Engineers 001 ASI-001 CJ 9/27/22 DT SURVEYED: SCALE: ■ s Ncm,°ien9ineers T.L. HORIZONTAL NAD 1983/1991 CITY 0 F WATERSHED APARTMENTS Lende pekc°&e 002 PROGRESSIVE CONSTRUCTION SET CJ 12/5/22 DT DESIGNED, PER SHEET - C°rsmunlyFanners 003 UPDATES PER CONDITIONS OF APPROVAL DT 1 /27/23 DT J.N. RENTON CONSTRUCTION DRAFT SET 004 GRADY WAY STORMWATER REVISIONS CW 12/26/23 TS DPA�: J.N. "eighb°rs ONE INCH DATUM 005 AS -BUILT REVISIONS AA 03/26/24 TS CHECKED: ' T A C O M A S E A T T L E DT AT FULL SCALE Planning/Building/Public Works Dept. UTILITY PLAN IF NOT ONE INCH 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422 TEL N 0. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 206.267.2425 TEL J CLI G LL a LU = DATE: 03/28/2023 FIELDBOOK: PAGE: LIJ P- DRAWING NO: C6.00 < ` SHEET'. Q OF: 48 CJ 0 0 0 0 N C\1 1 � � N N , z LU 75 Q Q 0 LU rr LU Q CITY OF RENTON WASTEWATER NOTES AND SPECS 1. ALL WORK AND WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/ APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/ BUILDING/ PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC RIGHT OF WAY. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. 4. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. ( INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON.) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 10. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE THE SAME AS DESCRIBED. 11. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED ROCK AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY THE CITY. 12. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/ BUILDING/ PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/ APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND BELOW THE PIPE. 15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50, UNLESS OTHERWISE APPROVED BY THE WASTEWATER UTILITY. 16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2' DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. FIRE PROTECTION NOTES 1. THE FIRE PROTECTION SYSTEM SHOWN ON THESE DRAWINGS, INCLUDING MATERIALS, SIZING, AND CONFIGURATION, IS SUBJECT TO APPROVAL BY A FIRE PROTECTION ENGINEER. THE DRAWINGS CONTAINING FIRE PROTECTION WORK, INCLUDING DETAIL DRAWINGS, SHALL BE STAMPED FOR APPROVAL BY A FIRE PROTECTION ENGINEER AND SUBMITTED TO THE FIRE MARSHAL FOR APPROVAL. 2. CONTRACTOR SHALL COMPLY WITH ALL NATIONAL FIRE PROTECTION ASSOCIATION REQUIREMENTS AS SET FORTH BY "NFPA 13", ITS AMENDMENTS, AND LOCAL REQUIREMENTS, INCLUDING BUT NOT LIMITED TO ACQUISITION OF ALL PERMITS. 3. THE FIRE PROTECTION SYSTEM SHALL BE INSTALLED BY A WASHINGTON STATE CERTIFIED LEVEL "U" CONTRACTOR IN ACCORDANCE WITH WAC 212-80-010. 4. CONTRACTOR'S BID SHALL REFLECT THESE CONDITIONS AND REQUIREMENTS. 5. FIRE SPRINKLER UNDERGROUND SUPPLY AND FDC REQUIRES A SEPARATE PERMIT FROM RENTON REGIONAL FIRE AUTHORITY. CONTRACTOR SHALL APPLY FOR AND OBTAIN PERMIT. 6. ACCORDING TO CITY RECORDS, THE ESTIMATED STATIC WATER PRESSURE IS 72 PSI. CITY OF RENTON WATER UTILITY NOTES AND SPECS UTILITY SPECIFICATIONS WATER UTILITY NOTES AND SPECIFICATIONS THESE NOTES SHALL APPEAR ON PROJECTS FOR THE WATER UTILITY. 1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT AT (425) 430-7301. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY WORK IN THE RIGHT OF WAY. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATES CALL 48-HOUR LOCATORS 800-424-5555. 4. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE SUBMITTED AT THE PRE -CONSTRUCTION MEETING. 5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL WATERMAIN PIPE IS TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO AWWA C110 AND C111 OR LATEST REVISION, THICKNESS CLASS 52. CEMENT MORTAR LINING AND SEAL COATING SHALL CONFORM TO AWWA C104 OR LATEST REVISION. PIPE JOINTS TO BE PUSH -ON OR MECHANICAL JOINT. BEDDING TO BE CLASS C. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE POLYETHYLENE WRAPPED PER ANSI/AWWA C105/A21.5-93 STANDARDS. 7. CAST IRON AND DUCTILE IRON FITTINGS SHALL BE CEMENT LINED, PRESSURE RATED AS NOTED ON PLANS, AND IN ACCORDANCE WITH ANSI/AWWA C110/A21.10-87. CEMENT LINING SHALL BE IN ACCORDANCE WITH ANSI/AWWA C104/421/4-90. IF FITTINGS ARE 3 TO 12 INCHES IN DIAMETER AND HAVE MECHANICAL JOINTS, THE FITTINGS SHALL IN ACCORDANCE WITH EITHER ANSI/AWWA C110-A21.10-87 OR ANSI/AWWA C153/A21.53-94. THREE (3) INCH TO 12 INCH DIAMETER FITTINGS, WHICH HAVE MECHANICAL JOINTS AND/OR FLANGED JOINTS, SHALL BE IN ACCORDANCE WITH ANSI/AWWA C110/A21.10.87 OR A COMBINATION OF ANSI/AWWA C110/A21.10.87 AND ANSI/AWWA C153/A21.53-94 SUCH THAT THE PORTION OF THE FITTING WITH A MECHANICAL JOINT(S) MAY BE WITH ANSI/AWWA C153/A21.53-94 AND THAT PORTION OF THE FITTING WITH FLANGED JOINT(S) SHALL BE IN ACCORDANCE WITH AWWA C110/A21.10-87. ACCEPTANCE TESTING IN ACCORDANCE WITH SECTION 53.53 OF ANSI/AWWA SECTION 10-4.3 OF ANSI/AWWA C110/A21.10-87 SHALL BE OBTAINED BY THE CONTRACTOR AND TRANSMITTED TO THE OWNER. 8. GATE VALVES SHALL BE IRON BODY, BRONZED -MOUNTED, DOUBLE DISC WITH BRONZE WEDGING DEVICE AND O-RING STUFFING BOX (AWWA C500) OR OF RESILIENT SEATED TYPE (AWWA C509).UTILITY SPECIFICATIONS VALVES SHALL BE DESIGNED FOR A MINIMUM WATER OPERATING PRESSURE OF 200 PSI. GATE VALVES SHALL BE CLOW LIST 14, MUELLER COMPANY NO. A2380 OR M&H. 9. FIRE HYDRANTS SHALL BE COREY TYPE (OPENING WITH THE PRESSURE) OR COMPRESSION TYPE (OPENING AGAINST PRESSURE) CONFORMING TO AWWA C-502-85 WITH A 6 INCH MECHANICAL JOINT INLET AND A MAIN VALVE OPENING (M.V.O.) OF 5-1/4 INCH, TWO 2-1/2 INCH HOSE NOZZLES WITH NATIONAL STANDARD THREADS 7-1/2 THREADS PER INCH AND ONE 4 INCH PUMPER NOZZLE WITH THE NEW SEATTLE PATTERN 6 THREADS PER INCH, 60 DEGREES V. THREADS: OUTSIDE DIAMETER OF MALE THREAD 4.875 AND ROOT DIAMETER 4.6263. HYDRANTS SHALL HAVE A 1-1/4 INCH PENTAGON OPERATING NUT OPENED BY TURNING COUNTER CLOCKWISE (LEFT). 10. THE TWO 2-1/2 INCH HOSE NOZZLES SHALL BE FITTED WITH CAST IRON THREADED CAPS WITH OPERATING NUT OF THE SAME DESIGN AND PROPORTIONS AS THE HYDRANT STEM NUT. CAPS SHALL BE FITTED WITH SUITABLE NEOPRENE GASKETS FOR POSITIVE WATER TIGHTNESS UNDER TEST PRESSURES. 11. THE 4 INCH PUMPER NOZZLE SHALL BE FITTED WITH A STORZ ADAPTER, 4 INCH SEATTLE THREAD X 5 INCH STORZ. STORZ ADAPTER SHALL BE FORGED AND/OR EXTRUDED 6061-T6 ALUMINUM ALLOY, HARDCOAT ANODIZED. THREADED END PORTION SHALL HAVE NO LUGS AND TWO SET SCREWS 180 DEGREES APART. STORZ FACE TO BE METAL, NO GASKET TO WEATHER. STORZ CAP TO HAVE SYNTHETIC MOLDED RUBBER GASKET, AND SHALL BE ATTACHED TO HYDRANT ADAPTER WITH 1/8 INCH, COATED, STAINLESS STEEL, AIRCRAFT CABLE. 12. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS OF PAINT. PRESERVATIVE PAINT NUMBER 43-655 SAFETY YELLOW OR APPROVED EQUAL. 13. PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. 14. FIRE HYDRANTS SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAIL FOR FIRE HYDRANTS, LATEST REVISION. 15. ALL WATERMAINS 10 INCHES AND SMALLER TO MAINTAIN A MINIMUM COVER OF 36 INCHES BELOW FINISH GRADE. ALL WATERMAIN 12 INCHES AND LARGER SHALL BE AT A MINIMUM OF 48 INCHES BELOW FINISH GRADE. WHERE UTILITY CONFLICTS OCCUR, WATERMAINS ARE TO BE LOWERED TO CLEAR. 16. ALL WATERMAINS 6 INCHES AND LARGER IN DIAMETER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE GIRARD INDUSTRIES AQUA SWAB -AS OR APPROVED EQUAL, 2 LB/CU. FT. DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY. 17. "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. THE CONTRACTOR WILL PERFORM THE CLEANING OPERATION. 18. ALL WATERMAINS AND SERVICES SHALL BE PRESSURE TESTED TO A MINIMUM OF 200 PSI OR 150 PSI OVER OPERATING PRESSURE, IN ACCORDANCE WITH THE SPECIFICATIONS OF THE CITY OF RENTON AND THE WASHINGTON STATE HEALTH DEPARTMENT. ALL PRESSURE TESTING SHALL BE DONE IN THE PRESENCE OF A REPRESENTATIVE OF THE CITY OF RENTON. THE QUANTITY OF WATER LOST FROM THE MAIN SHALL NOT EXCEED THE NUMBER OF GALLONS PER HOUR AS LISTED IN CITY OF RENTONUTILITY SPECIFICATIONS STANDARD PLANS & SPECIFICATIONS 7-11.3(11). THE LOSS IN PRESSURE SHALL NOT EXCEED 5 PSI DURING THE 2 HOUR TEST PERIOD. 19. ALL WATERMAINS AND SERVICES SHALL BE DISINFECTED BY THE INJECTION OF A 50 PPM (MINIMUM CONCENTRATION) CHLORINE/WATER SOLUTION. DRY CALCIUM HYPOCHLORITE SHALL NOT BE PLACED IN THE PIPE AS LAID. CHLORINE SHALL BE METERED/INJECTED IN ACCORDANCE WITH SECTION 7-11.3(12)E OR 7-11.3(12)F OF THE STANDARD SPECIFICATIONS REFERENCED ABOVE. 20. A PRE -CONSTRUCTION CONFERENCE IS REQUIRED PRIOR TO ANY CONSTRUCTION. A MINIMUM OF FIVE (5) WORKING DAYS NOTICE IS REQUIRED FOR SCHEDULING. 21. TWENTY-FOUR (24) HOURS NOTICE WILL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. 22. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. 23. INSTALLATION OF CORPORATE STOPS, WATER SERVICES, LINES AND METERS SHALL NOT BE DONE UNTIL ALL SERVICE AGREEMENTS, METER APPLICATIONS, CONSTRUCTION PERMITS, AND PAYMENT OF FEES HAVE BEEN MADE TO THE CITY OF RENTON. 24. ALL CONNECTION TO EXISTING MAINS IS TO BE ACCOMPLISHED BY THE CITY OF RENTON, EXCEPT WET TAPS, WHICH MAYBE MADE BY APPROVED WET TAP CONTRACTORS WITH PRIOR APPROVAL FROM THE PUBLIC WORKS DEPARTMENT. ALL NECESSARY EXCAVATION AND MATERIALS ARE TO BE SUPPLIED BY THE CONTRACTOR AND BE ON -SITE PRIOR TO CITY NOTIFICATIONS. 25. INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY DEVELOPMENT SERVICES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. THE CONTRACTOR, AS WELL AS THE ENGINEERS, SHALL KEEP AS -BUILT DRAWINGS. 26. CONTRACTOR TO PROVIDE PLUGS AND TEMPORARY BLOW -OFF ASSEMBLIES FOR TESTING AND PURITY ACCEPTANCE PRIOR TO FINAL TIE-IN. 27. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS OHIO, OR EQUAL, APPROVED IN WRITING BY THE PUBLIC WORKS DEPARTMENT. 28. ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES. OIL MAT STREETS MAYBE SPADE CUT. ALL SURFACE CONCRETE, PAVEMENT, SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO (2) INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. 29. A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, TO CITY OF RENTON POLICY, WITHIN 10 DAYS. CALL FOR SUBGRADE INSPECTION PRIOR TO PLACEMENT OF FINAL PATCH*. 30. FOR CITY PROJECTS SUCH AS TELEMETRY CONDUIT, THE PVC PIPE USED SHALL BE ALL CHEMICAL PROCESS LINES SHALL BE SCHEDULE 80 PVC PIPE. SCHEDULE 40 IN UNIMPROVED AREAS AND SCHEDULE 80 PVC PIPE UNDER IMPROVED AREAS. S-420002 RECORD NOTE 03/26/2024 W-420002 TOP h,�' THESE RECORD DRAWINGS HAVE BEEN OY WAS# � PREPARED BASED ON SURVEY INFORMATION IN COMPLIANCE WITH CITY OF RENTON STANDARDS PROVIDED BY A THIRD -PARTY SURVEYOR. AHBL WILL BE RESPONSIBLE FOR THE DATA - PROVIDED BY THEM. THE THIRD -PARTY SURVEYOR WILL BE RESPONSIBLE FOR THE 4 16 STERE9 ACCURACY OF THE ACTUAL LOCATIONS IN THE I ��ssIGI T EFIELD. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. 1 / Civil Engineers 001 ASI-001 CJ 9/27/22 DT s1'E'ED' SCAM DATE` ■ Shu1N,°IE19ieeers T.L. HORIZONTAL- NAD 1983/1991 CITY OF WATERSHED APARTMENTS 03/28/2023 002 PROGRESSIVE CONSTRUCTION SET CJ 12/5/22 DT DESIGNED, PER SHEET c - °rsm°°imPenners 003 UPDATES PER CONDITIONS OF APPROVAL DT 1/27/23 DT J.N. CONSTRUCTION DRAFT SET FIELDBOOK: 004 GRADY WAY STORMWATER REVISIONS CW 12 26 23 TS D� RENTON DRAWING O / / J.N. DATUM DRAWING NO: w NQ19°°°rs 005 AS -BUILT REVISIONS AA 03/26/24 TS CHECKED: AT FULL ONE INCH 0 Know what's below. IF NOT ONESCALE N H T A C O M A SEATTLE DT Planning/Building/Public Works Dept. NOTES .z Call before you dig 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422 TEL NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY SHEET: OF: 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 206.267.2425 TEL 19 48 T 1410" N U H H T N Q J H H T N n z LU G Q a 0 LU 2 Ir LU I - a • • CV r.' ►740 ONE V ) Z W 75 Q n 0 Uj V rr2 JJ rr ui 6mi a Z W w BOLTHOLES - 3 PLCS EQUALLY SPACED 120" APART ON 23 1/16' (5861 DIA BC (SEE DETAIL) COVER & FRAME PLAN VIEW 25' DIA C6351111] 1' 3/4'251 C19r1r17 8 3/4' 2 1/2' C222mml 164mml TYP COVER SECTION VIEW 26 112' DIA [67311r1] 25 1/4' DIA C64111r1] 1 1/16' 1/4' (61m1) DIA C27ror1] NEOPRENE GASKET 6. 1 7t C15' 2 roro] 5/8" 23 3/8' DIA CL ❑PEN C16ro11] [594rm1] 27 5/16' DIA [694mm] 34 1/8' DIA COVER BOTTOM VIEW (3) BLT SOC (ALLEN HEAD) 5/8'-11 X 15 SS RUBBER WASHER ALL BOLTING DETAIL 1/4' 1 1/16' C 61111] C27MM] 1/8' Minn] [R3nr1] GASKET GROOVE DETAIL [8671 NOTES FRAME SECTION VIEW 1 ALL FRAME AND COVER ASSEMBLIES SHALL HAVE A LOCKING LID PER EAST JORDAN IRON WORKS INC PRODUCT No 00371572 OR EQUAL. 2 USE FRAME AND COVER FOR SANITARY (SPECIFY "SFWFR") STD. PLAN - 401.1 PUBLIC WORKS SEWER MANHOLE FRAME AND COVER Ei1. 19nedby VRIDEPARTMENT (CITY -OWNED) Martin PastucunaIj z iLkIU449u DATE SEWER MANHOLE FRAME AND COVER W (SEE NOTE 7) BEDDING MATERIAL FOR SANITARY SEWER PIPE (SEE NOTE 5) FOUNDATION LEVEL LIMITS OF PIPE ZONE MIN O.D. of PIPE BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS 5 PIPE ZONE MATERIAL SHALL BE PER SECTION 9-03.12(3) OF THE STANDARD SPECIFICATIONS 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED 7 TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. STD. PLAN - 405 URIPUBLIC WORKS PIPE BEDDING APP DEPARTMENT FOR SANITARY SEWERS Martin Pastucha 26/202c v„or, wan. n­fflWWamF Uy8�3449U DATE NOT TO SCALE ` L I NOT TO SCALE Know what's belOW. Call before you dig. CONNECT TO MECHANICAL PER PLUMBING 35 30 25 22 C� w SSCO #3 N: 175923.46 E: 1300644.07 RIM: 31.94 IE IN: 25.14 (8"NE) IE OUT: 25.14 (8"SE) SSCO #1 N: 175906.52 E: 1300654.93 RIM: 31.73 IE IN: 24.94 (8"NW) IE OUT: 24.94 (8"SW) SSCO #1A N: 175895.01 E: 1300646.15 RIM: 31.67 IE IN: 24.45 (8"NE) IE OUT: 24.45 (8"SW) SOUTH PROPERTY WEST LINE EX SEWER MANHOLE N: 175873.92 E: 1300602.94 RIM: 30.83 IE IN: 23.49 (8"NE) USE INSIDE DROP CONNECTION IE OUT: 20.98 (8"SW) 35 .�■M 30 MANHOLE CONNECTION SHALL BE CORE DRILLED. USE CORE N SEAL CONNECTORS OR APPROVED EQUAL. 25 22 C7 LL 0+00 0+50 0+94.12 FINISHED GRADE AT SEWER CENTER LINE EXISTING GRADE AT SEWER CENTER LINE SEWER PROFILE SCALE: 1" = 20' (H) 1"=10'(V) RECESSED LIFT POCKET 3/4" LETTERING "SEWER" (2) BOLT SOC. (ALLEN HEAD) 5/8" - 11 X 1 5 STAINLESS STEEL REF PART #00981177 �---� 1 -3/16" -1 O-1/2"-�{ 5/I 1/4,,,2-1/2"ill 2-1/4" 14" �I CAST IRON RING AND COVER Not to Scale FRAME 1'-(1 ninurTrn 1 -(1" 45• (1/8) BEND OR DABLE PIPE MATERIAL AS SPECIFIED BY THE ENGINEER NOTES. 1 8" AND 6" CLEAN -OUT RINGS AND COVERS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC No 3698 (PRODUCT NO 00369803) OR APPROVED EQUAL CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY 2 IN UNIMPROVED AREAS, POUR A 8" THICK, 3'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER 3 INSTALL ASPHALT COLLAR PER STANDARD PLAN 106 STD. PLAN - 403.1 . i PUBLIC WORKS 8" OR 6" CLEANOUT nI,d by DEPARTMENT FOR SANITARY SEWER MAIN Martin Pastuclia/26/2020 'VQ=,,VM49D DATE SANITARY SEWER CLEANOUT NOT TO SCALE !' OP �y"SST OA F TCASgINC�tS1 f?f °•p 46416sv� O GISTERE9 IONAL will d" Civil Engineers strucrwarEnglneers ede��A,°n;re°rs °rsmuniyFlanners Q [no O °°°S° ey°rs "eighb°rs TACO MA • S EATTLE 2215 North 30th Street, Suite 300, Tacoma, WA 98403 253.383.2422 TEL 1200 Sixth Avenue, Suite 1620, Seattle, WA 98101 206.267.2425 TEL 001 ASI-001 CJ 9/27/22 DT SURVEY D' T.L. SCALE: PER SHEET HOR O VERTICAL I•AL• N i 19aa 991 DATUM 002 PROGRESSIVE CONSTRUCTION SET CJ 12/5/22 DT DESIGNED: J.N. 003 UPDATES PER CONDITIONS OF APPROVAL DT 1/27/23 DT 004 GRADY WAY STORMWATER REVISIONS CW 12/26/23 TS D� J.N. ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 005 AS -BUILT REVISIONS AA 03 /26/241 TS CHECKED: DT N 0. REVISION BY DATE AP P R APPROVED: r--i-r---------- �� EX. SEWER MAIN I I I I i i I PROPERTY LINE -SPOOL I 1 I ? (LENGTH AS NEEDED) i 3'-0" MIN 6" SEWER STUB ,' FUTURE 4" SIDE SEWER \ 2"x 4" STUD MARKING POST PAINTED t I I I 6" CAP JJJ WHITE WITH THE WORD "SEWER" STENCILED `SEWER MAIN TEE X 6" TEE i i i i I IN 3" HIGH BLACK LETTERS AND #6 WIRE SIDEWALK i . z WRAPPED AROUND THE STUD AND I I I I _1 EXTENDED TO THE TOP OF THE STUD COUPLING TYP I I I L_J_L_________J G ( ) e>.� 13 � 1SURFACE CLEANOUT WITH CAST IRON RING AND COVER 10 I (EAST JORDAN IRON WORKS PRODUCT NO 00367502 OR 1- APPROVED EQUAL, SPECIFY "SEWER" ON LID), 9 CLEANOUT TO BE CENTERED IN A 2'x2' CONCRETE PAD CONCRETE PAD TO BE 8" IN DEPTH r r---- ----- 1 ----------------------r-J r----- ---- -„. L---J BEND AS g" REQUIRED EXISTING SANITARY _ SEWER MAIN r---2 OR MIN SLOPE ]3 \ FUTURE 4" SIDE SEWER "6" SEWER STUB 6"X6"X6" WYE FUTURE 6"x 4" REDUCER `SEWER MAIN SIZE X 6" TEE ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO EXISTING SEWER MAIN A VITRIFIED CLAY MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B CONCRETE MAIN - CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL) C PVC do C900 PVC MAIN - CUT IN NEW TEE USING RIGID COUPLINGS OR CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E LINED MAIN - CONNECTION TO SEWER MAINS THAT HAVE BEEN LINED (CIPP, ETC), CUT IN A NEW PVC "TEE" USING "STRONG -BACK" FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). F HDPE - CORE -DRILLED WITH A ROMAC SADDLE "INSERTA-TEE" MAY BE USED ON SEWER MAINS 12" DIAMETER OR LARGER G MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED AND USE KOR-N-SEAL BOOTS OR APPROVED EQUAL NOTES- 1 PRIOR TO INSTALLATION OF A SANITARY SEWER STUB, A SIDE SEWER STUB PERMIT MUST BE PURCHASED FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT 2 UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 25' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER 3 SIDE SEWERS SHALL HAVE A MINIMUM 2 % SLOPE UNLESS APPROVED BY THE PUBLIC WORKS INSPECTOR 4 FOR INSPECTION OF THE SIDE SEWER STUB, CALL 24 HOURS IN ADVANCE. THE INSPECTION PHONE NUMBER IS ON THE SIDE SEWER STUB PERMIT SITE MUST BE READY FOR INSPECTION AND A REPRESENTATIVE ON SITE WHEN INSPECTOR ARRIVES AT THE APPOINTED TIME DO NOT BACKFILL THE TRENCH UNTIL APPROVAL IS GIVEN BY THE INSPECTOR 5 ALL TRENCH RESTORATION FOR SIDE SEWERS IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO STANDARD PLAN 110 OR 1102 6 THE SIDE SEWER STUB SHALL HAVE PIPE BEDDING IN ACCORDANCE WITH STANDARD PLAN 405 7 ALL SIDE SEWER STUBS SHALL BE INSTALLED BY A CONTRACTOR LICENSED AND BONDED IN THE STATE OF WASHINGTON SIDE SEWER STUB STD. PLAN-ao6.1 PUBLIC WORKS APP r INSTALLATION DEPARTMENT Martin PastUCl�@y26/202 (SEWER MAIN TO PROPERTY LINE) Pb<t�3T U98"64a9D - DATE SIDE SEWER CONNECTION NOT TO SCALE RECORD NOTE 03/26/2024 THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED ON SURVEY INFORMATION PROVIDED BY A THIRD -PARTY SURVEYOR. AHBL WILL BE RESPONSIBLE FOR THE DATA PROVIDED BY THEM. THE THIRD -PARTY SURVEYOR WILL BE RESPONSIBLE FOR THE ACCURACY OF THE ACTUAL LOCATIONS IN THE FIELD. THOSE RELYING ON THIS RECORD DOCUMENT ARE ADVISED TO OBTAIN INDEPENDENT VERIFICATION OF ITS ACCURACY BEFORE APPLYING IT FOR ANY PURPOSE. CITY OF RENTON (D Planning/Building/Public Works Dept. U T Ir n S-420003 I� IN COMPLIANCE WITH CITY OF RENTON STANDARDS 7 WATERSHED APARTMENTS CONSTRUCTION DRAFT SET PUBLIC SEWER DETAILS W G Q IZ a 0 LLI = DATE: 03/28/2023 MU DBOOK: PAGE: Uj � DRAWING NO: C6.80 a SHEEE: OF. 26 48