Loading...
HomeMy WebLinkAboutT-4200010 0 N 0 GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH RENTON STANDARD SPECIFICATIONS, RENTON STANDARD PLANS, AND THE CONTRACT, UNLESS OTHERWISE NOTED. A COPY OF THESE DOCUMENTS SHALL BE ON SITE DURING CONSTRUCTION. 2. A COPY OF THE APPROVED PLAN SHALL BE ON SITE DURING CONSTRUCTION. 3. ALL PERMITS REQUIRED FOR WORK WITHIN THE PUBLIC RIGHT OF WAY MUST BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. THE LOCATION OF EXISTING FEATURES AND UTILITIES SHOWN WITHIN THESE PLANS ARE APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCING LIGHTING WORK. NOT ALL EXISTING FEATURES AND UTILITIES MAY BE SHOWN. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT UTILITY AGENCIES 48 HOURS PRIOR TO COMMENCING WORK AND SHALL COORDINATE WITH ALL AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING UTILITIES RESULTING FROM CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AGENCY IMMEDIATELY UPON DAMAGE AND SHALL BE RESPONSIBLE FOR REPLACING DAMAGED EQUIPMENT TO THE SATISFACTION OF THE AFFECTED UTILITY AGENCY. 6. THE CONTRACTOR SHALL SALVAGE AND DELIVER ALL EXISTING LIGHTING EQUIPMENT SPECIFIED FOR REMOVAL BACK TO CITY OF RENTON, UNLESS OTHERWISE NOTED IN WRITING BY THE ENGINEER. 7. THE LOCATIONS OF PROPOSED CONDUITS AND JUNCTION BOXES SHOWN IN THESE PLANS ARE GRAPHICAL REPRESENTATIONS ONLY. THE CONTRACTOR SHALL FIELD VERIFY FINAL LOCATIONS WITH THE ENGINEER PRIOR TO INSTALLATION. 8. THE CONTRACTOR SHALL FIELD VERIFY FINAL LOCATIONS OF ALL PROPOSED FOUNDATIONS WITH THE ENGINEER PRIOR TO EXCAVATION. 9. PROPOSED JUNCTION BOXES LOCATED WITHIN SIDEWALKS AND CURB RAMPS SHALL BE EQUIPPED WITH SLIP -RESISTANT LIDS. 10. TYPE 1 BOXES SHALL BE INSTALLED PER WSDOT STANDARD PLAN J-40.10. LUMINAIRE POLE SCHEUDLE LUMINAIRE RENTON POLE CENTERLINE REFERENCE STATION OFFSET LONGITUDE LATITUDE LUMEN OUTPUT MOUNTING ARM WATTAGE DISTRIBUTION LUMINAIRE TYPE NOTES POLE NO. NO.*** **** **** HEIGHT LENGTH �1 ** WILLIAMS AVE S EX EX 4,500 19FT (EX.) 6FT (EX.) 53W (EX.) III GE EVOLVE ESR1 EX TO REMAIN �2 * S GRADY WAY EX EX 11,936 35FT (EX.) 16FT (EX.) 105W (EX.) III AUTOBAHN ATBO EX TO REMAIN �3 * S GRADY WAY 11 +14.1 45.1 FT LT 23,200 (ROADWAY) 35FT 4FT 20OW (ROADWAY III CYCLONE DOMIA (ROADWAY) ❑4 * S GRADY WAY EX EX 23,400 40FT (EX.) 16FT (EX.) 105W (EX.) III AUTOBAHN ATBO EX TO REMAIN �5 * S GRADY WAY EX EX 16,702 30FT (EX.) 6FT (EX.) 130W (EX.) III AUTOBAHN ATB2 EX TO REMAIN �6 * S GRADY WAY EX EX 16,702 30FT (EX.) 8FT (EX.) 130W (EX.) III AUTOBAHN ATB2 EX TO REMAIN 16,300 (ROADWAY), 35FT, 140W (ROADWAY), I CYCLONE DOMIA (ROADWAY), ❑* 7 WILLIAMS AVE S 21 +31.3 25.OFT LT 2,582 (PEDESTRIAN) 16.5FT 4FT' 4FT 20W (PEDESTRIAN) III CYCLONE DOMIA MINI (PEDESTRIAN) 8 * S GRADY WAY 12+03.8 33.8FT LT 2,582 (PEDESTRIAN) 16.5FT 4FT 20W (PEDESTRIAN) III CYCLONE DOMIA MINI (PEDESTRIAN) 23,200 (ROADWAY), 35FT, 20OW (ROADWAY), I CYCLONE DOMIA (ROADWAY), ❑* 9 S GRADY WAY 12+82.1 33.8FT LT 2,582 (PEDESTRIAN) 16.5FT 4FT' 4FT 20W (PEDESTRIAN) III CYCLONE DOMIA MINI (PEDESTRIAN) 10 * WILLIAMS AVE S 21+96.1 25.0FT LT 2,582 (PEDESTRIAN) 16.5FT 4FT 20W (PEDESTRIAN) III CYCLONE DOMIA MINI (PEDESTRIAN) * CITY OF RENTON LIGHTING ** PUGET SOUND ENERGY LIGHTING *** CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL (425) 430-7423 FOR POLE NUMBERS TO BE INCLUDED ON POLES. **** CONTRACTOR SHALL DETERMINE FINAL COORDINATES FOR RECORD DRAWINGS. 11. THE CONTRACTOR SHALL LABEL ALL CONDUCTORS FOR STREET LIGHTS WITHIN EACH CONSTRUCTION NOTES JUNCTION BOX. O1 INSTALL CYCLONE 140W LED TYPE III LUMINAIRE (C755P1A-FGC-3-14OW-4K-120-277-ADV-PX-BK) AT 35FT MOUNTING HEIGHT WITH 4FT MAST ARM AND CYCLONE 20W LED TYPE III LUMINAIRE (SY21PA-FGC-3-20W-4K-BK) AT 16.5FT MOUNTING HEIGHT ON POLE PER CITY OF RENTON STANDARD PLAN 117.1A. 12. THE CONTRACTOR SHALL REMOVE ALL EXISTING CONDUCTORS ASSOCIATED WITH EXISTING INSTALL LUMINAIRE CONCRETE PAD AND JUNCTION BOX CONCRETE PAD. SEE GENERAL NOTE 23. LIGHTING EQUIPMENT SPECIFIED FOR REMOVAL, UNLESS OTHERWISE NOTED. CAP AND ABANDON EXISTING UNUSED CONDUIT. REMOVE PORTIONS OF ABANDONED CONDUIT WHERE IN CONFLICT WITH NEW CONDUIT, UNLESS OTHERWISE NOTED. O2 INSTALL CYCLONE 20W LED TYPE III LUMINAIRE (SY21 PA-FGC-3-20W-4K-BK) ON 4FT ARM AT 16.5FT MOUNTING HEIGHT AND DECORATIVE FLOWER BASKETS ON POLE PER CITY OF RENTON STANDARD PLANS 117.2 AND 117.4. INSTALL LUMINAIRE CONCRETE PAD AND JUNCTION BOX CONCRETE PAD. SEE GENERAL NOTE 23. 13. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT O3 PROTECT EXISTING LUMINAIRE AND POLE TO REMAIN. THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE ® INSTALL TYPE 1 JUNCTION BOX. PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THIS PLAN. AS THE FIRST ORDER OF BUSINESS, THE CONTRACTOR SHALL POTHOLE EACH LOCATION TO O INTERCEPT EXISTING CONDUIT WITH NEW CONDUIT IN -KIND AND ROUTE CONDUIT INTO NEW JUNCTION BOX. SPLICE CONDUCTORS INTO EXISTING ILLUMINATION CONFIRM THAT THERE ARE NO CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED CIRCUIT. BETWEEN OVERHEAD POWER LINES AND THE PROPOSED STREETLIGHT POLES PRIOR TO CONSTRUCTION. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. © INSTALL CYCLONE 20OW LED TYPE III LUMINAIRE (C755P1A-FGC-3-20OW-4K-120-277-ADV-PX-BK) AT 35FT MOUNTING HEIGHT WITH 4FT MAST ARM AND THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS CYCLONE 20W LED TYPE III LUMINAIRE (SY21PA-FGC-3-20W-4K-BK) AT 16.5FT MOUNTING HEIGHT ON POLE PER CITY OF RENTON STANDARD PLAN 117.1A. DISCOVERED. INSTALL LUMINAIRE CONCRETE PAD AND JUNCTION BOX CONCRETE PAD. SEE GENERAL NOTE 23. 14. LUMINAIRE WIRING SHALL BE PER THIS PLAN AND CITY OF RENTON STANDARD PLAN 119. O REMOVE AND SALVAGE EXISTING LIGHT POLE. ® RELOCATE SIGNS ON EXISTING LIGHT POLE TO NEW LIGHT POLE. MOUNT SIGNS PER CITY OF RENTON STANDARD PLAN 129. 15. STREET LIGHT POLES SHALL BE NUMBERED PER CITY OF RENTON STANDARD PLAN 121. COORDINATE WITH THE CITY OF RENTON FOR NUMBERING. O9 INSTALL CYCLONE 20OW LED TYPE III LUMINAIRE (C755P1A-FGC-3-20OW-4K-120-277-ADV-PX-BK) AT 35FT MOUNTING HEIGHT WITH 4FT MAST ARM ON POLE PER CITY OF RENTON STANDARD PLAN 117.1A. INSTALL LUMINAIRE CONCRETE PAD AND JUNCTION BOX CONCRETE PAD. SEE GENERAL NOTE 23. 16. FUSING AND/OR SPLICING OF LUMINAIRE WIRING SHALL BE PER CITY OF RENTON STANDARD PLAN J013. 17. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I.E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 18. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 19. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 20. LUMINAIRE FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 21. ALL ILLUMINATION SYSTEM ARE SUBJECT TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE. 22. CONTRACTOR SHALL CONTACT TRANSPORTATION MAINTENANCE MANAGER, ERIC CUTSHALL, (425) 430-7423 FOR STREET LIGHTING INSPECTION PRIOR TO ENERGIZING. 23. THE CONTRACTOR SHALL SUBMIT, FOR REVIEW BY THE ENGINEER, DESIGNS FOR THE LUMINAIRE POLE FOUNDATIONS THAT BEAR THE SEAL AND SIGNATURE OF A VALID LICENSED WASHINGTON STATE PROFESSIONAL ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY STRUCTURAL AND/OR GEOTECHNICAL ANALYSIS THAT MAY BE NEEDED TO DETERMINE THE NECESSARY FOUNDATION DEPTHS FOR THE ARTERIAL STREET DECORATIVE LUMINAIRE POLES AND THE ARTERIAL PEDESTRIAN LUMINAIRE POLES, IN ACCORDANCE WITH CITY OF RENTON STANDARD PLANS 117.1 AND 117.2. A GEOTECHNICAL ENGINEER SHALL BE PRESENT AT THE TIME OF BORING OF THE FOUNDATION TO VERIFY SOIL CONDITIONS. 3 6 DATE DESIGNED BY MRW 05/12/2022 DRAWN BY MRW 05/12/2022 REVIEWED BY CAC 05/12/2022 LEGEND DESCRIPTION EXISTING PROPOSED RIGHT-OF-WAY - - CONDUIT - P(UG) P(UG) P(UG) P(UG) - CONSTRUCTION NOTE LUMINAIRE POLE NOTE # WIRE NOTE ROADWAY AND PEDESTRIAN LUMINAIRE AND POLE ROADWAY LUMINAIRE AND POLE PEDESTRIAN LUMINAIRE AND POLE® TYPE 1 JUNCTION BOX 19 m SERVICE CABINET VN 0 5014, r, • I' Q'il i���!RI•A����II����II��II��I��S-::.-����:1�7G;� ���+!i� �I WIRING SCHEDULE NO RACEWAY CONDUIT SIZE* CONDUCTOR COMMENTS 1 2" SCH40 2-#8 2 2" SCH80 2-#8 3 EX 4-#8 4 2" SCH40 4-#8 T uc / I_ _ _ _ -li *ALL CONDUIT SHALL BE PVC AND SHALL CONTAIN A GROUND WIRE ,, i w - w -� EQUAL IN SIZE TO THE LARGEST CONDUCTOR (MINIMUM NO. 8) UNLESS 1�1 t o w w w- w- w OTHERWISE NOTED. --�u--w_w=wow - w I Y 8 I I - - --- _ -- _ - - ---- - _ ��� w-w 15+00 - -jw w-w=w- "�W - w-w-w- w-�-w-w w-w-w-w-w-w w-w- S G A D Y WAY ! \ 10 �� - / _ - - 11+00 0 012+00 �- - - o \ O G� I co Ln No c G- G- G- G G G- G G- G -� V'- G '���--------------------------��----- - FIFL G- G- G- G- G G- G " G- G- G- G- G- G- G- u ----------------------- ---------- SO--- ---------------------------- ----------------------------- - -- - 1, - P(- �- P(UG) `off _ �U P(UG� P(UG) P(UG) ® _ - SD $p SD - SD - SD SD SD SD �D=S"D-�LfD - SD - D - SD SD F y "Y(UG) T(UG) P(UG) PCUG) REVISION BY DATE IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING TRANSPORTATION OPERATION JChavez 05/17/2022 CBarnes 05/17/2022 P(UG) P(UG) t � I - P(UG) I P(UG) transpogroulo AUF WHAT TRANSPORTATION CAN BE. 12131 113TH AVENUE NE, SUITE 203 (TEL) 425 821-3665 KIRKLAND, WASHINGTON 98034 (FAX) 425 825-8434 T-420001 GMD RENTON 0 � s°E\���� �til CITY OF RENTON NAL ILLUMINATION P LA N 0 Know hat's below. I I before you dig. MAY 2022 IL01 SHEET 1 OF 10 SHEETS