HomeMy WebLinkAboutT-4200040
0
N
I
T-
0
rr
DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959
z: :7
OO "' V
C) &
LU
LU OOOO OOOO t0
hl
I-(D2m W
ZzCD0>
W W pH
-1 1: W W
m=w
mm: I-
Z
QQm1->AUUUW=aO
~AQ
0z0w
HZZHaWH-
LU
�
_
Wm
w=LLmHLLF
OWHW
O
Z�W
9 x -
J
z Z W m
�
V Z LL
O = W
U-LU_j Z
0LU U)Z
0
ZwgO�
LU=
�o
wci)
JW�=o
Hz 2Z
LU >
W W(1)
H
2 W H
H g F-
W Q Z _ J
Q W U
J
j=
> Q m
U
Q
w
U
In
C9
z
Of
LU
W IY
�3:
0 =
�J 1-H
av r(n
z
z
0
Of
Q Go
OO �L EO
ZJ~ F-m F- W0a0
O a U U
N
N
z
} d
N Y
Q
z Q
10�a.
~
0 LUO
LL In
w
O
z
►�i
w
M
I-i
Q
a
w
0
z_
0
N
O
SERVICE CABINET App gg PLAN
- 122.1
®� PDEPAR DEPAUBLIC RTMENT Martin 11 astUCfyj8/2021 1 4:?
FNS�
DATE
DocuSign Envelope ID: 5D308A1A-204D-48E8-BB23-8A2834BB565E
GENERAL NOTES:
1. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF
THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE
POLES, TRAFFIC SIGNAL POLES, SIGN POSTS).
2. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE
ONCE CONSTRUCTION IS COMPLETE.
3. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION
LIMITS SHALL MEET CURRENT ADA STANDARDS(I.E. JUNCTION BOXES SHALL HAVE NON-SKID
LIDS).
4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION
TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK.
5. ALL TRANSPORTATION ASSETS THAT ARE TO BE REMOVED AND THEN REINSTALLED AT A LATER
DATE DURING CONSTRUCTION SHALL BE RE -INSTALLED TO CURRENT STANDARDS.
6. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE.
7. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS
SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK
SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST
2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS.
8. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, VEHICLE DETECTION SHALL BE MAINTAINED AND
REMAIN FUNCTIONAL. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED
AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING VEHICLE DETECTION.
9. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION
SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS
MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE
INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER
TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE.
G PUBLIC WORKS
DEPARTMENT
1
TRANSPORTATION NOTES
STD. PLAN - 135
-ArrPRGAZovED: 3/13/2019 1 4
DATE
1
DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959
UUMPOINLIN"1' SCHLllULL
OMETERBASE: 200 AMP, 4 JAW, MANUAL BYPASS, B-LINE U264
W/ STH JAW AT 9:00 POSITION
O PANELBOARD: 120/240 VAC, 125 AMP COPPER BUS, 1 PHASE, 3 WIRE, 18 CKT, IOK AIC
MAIN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON ED2200
BOLT -ON BRANCH BREAKERS, EATON TYPE BAB:
2 - 20/2 ILLUMINATION A, B
1 -20/1 ITS
1 - 20/1 GROUND FAULT RECEPTACLE
1 - 40/1 SIGNAL (IF PRESENT)
1 - 40/1 AUXILLIARY SIGNAL (IF PRESENT)
2 - 60/2 SMALL CELL BRANCH
1 - 1511 CONTROL
3 - 20/1 SPARE
O CONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL,
SQD 891ODPA34VO2 -I REQUIRED
40 PHOTO ELECTRIC CELL: 1800 WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL
MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW
50 PHOTO -CELL BYPASS SWITCH:
SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK)
OGROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX
CABINET:
CONSTRUCTION:
NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8" 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM
FRAMED WITH 2" ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT
MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDING WIRE TO NEUTRAL
DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE),STAINLESS STEEL VAULT HANDLES WITH
ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET,
"BEST" LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER,
PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW
DEADFRONT: HINGED AND SECURED WITH QUARTER -TURN FASTENERS
FINISH: MILL FINISH ALUMINUM
1 - REQUIRED
UL LISTED PER STANDARD #508A
"SUITABLE FOR USE AS SERVICE ENTRANCE"
NOTE:
1. SIGNAL BREAKER(S) SHALL BE ADDED WHEN APPLICABLE
��Y 0 SERVICE CABINET NOTES pLAN - 122.2
PUBLIC WORKS ApPROV D:
A DEPARTMENT Martin aStuCfj*8/2021 1 4
NSA
DATE
. a.. MOEN ice
M £
1 /4" LOAD FUSE LINE 1 /4"
r
1/8" QO O 1/S"
CUTTING RINGS
FUSE KIT
r ► �o��rir
VV T C 3F`LIt r-
SPLICE KIT FUSE KIT & SPLICE KIT DETAILS
1 p ADOPTED
CITY OF RENTON
+LL
STANDARD PLANS
IST DATE: 04/04
...ram ..-......,... .... nwr NA1/F, In1I CP PArF•.In13
DATE REVISION BY DATE
DESIGNED BY MRW 05/12/2022 0 RECORD DRAWINGS KLW 8/27/2024
DRAWN BY MRW 05/12/2022
REVIEWED BY CAC 05/12/2022
DocuSign Envelope ID: 5D308A1A-204D-48E8-BB23-8A2834BB565E
CONDUIT ENTRANCE AREA
k
PLAN VIEW
SIZE TO FIT SIZE TO FIT
CABINET CABINET
6" 6"
I' -GRADE LEVEL
N
a
FRONT VIEW SIDE VIEW
ELECTRICAL SERVICE CABINET FOUNDATION
ti o
PUBLIC WORKS
DEPARTMENT
BAND
OR
SHIM TO PLUMB
SEE NOTE 3
o #4 HOOPS
fiIIT #4 BARE11T CORNER
6" MIN 1" TO 2"
3/8" DIAMETER PLASTIC DRAIN
SIDE VIEW
CABINET DEPTH
+ 2"
H
- - - - - #4 BAR EACH
+ i AP I #4 CORNER
m +III _HOOPS
Li Li
PLAN VIEW
CONTROLLER CABINET FOUNDATION
NOTES PER STD PLAN 126.2
CABINET FOUNDATION
DETAILS
STD. PLAN - 126.1
$OVED: 3/13/2019 I
DATE
NOTES
1. DIMENSIONS FOR THE PARTS USED TO ASSEMBLE THE BASE
CONNECTIONS ARE INTENTIONALLY NOT SHOWN. BASE
CONNECTIONS ARE PATENTED. MANUFACTURED PRODUCTS
THAT ARE IN COMPLIANCE WITH NCHRP 350 CRASH TEST
CRITERIA. THE BASE CONNECTION DETAILS ARE SHOWN ON
THIS PLAN ONLY TO ILLUSTRATE HOW THE PARTS ARE
ASSEMBLED.
2. A 2" (IN) POST WITH A 2 1/4" (IN) PSST ANCHOR OR A 2
1/4" (IN) POST WITH A 2 1/2" (IN) PSST ANCHOR MAY BE
SUBSTITUTED. SEE CONTRACT PLANS.
3. PERFORATED SQUARE STEEL POST SHALL MEET THE
REQUIREMENTS OF WSDOT STANDARD SPECIFICATION 9-06.
4. USE ONLY BASE CONNECTION MANUFACTURER SUPPLIED
HARDWARE THAT MEETS THE REQUIREMENTS OF WSDOT
STANDARD SPECIFICATIONS 9-06 AND 9-28.
MOUNTING ON EXISTING
METAL POLE OR LUMINAIRE EDGE OF TRAVELED
ROAOWAY
90 30'-�
4" MIN. T
EDGE OF
bIGN FOR REFLECTORIZED SIGNS: MOUNT
5/16"x2-1 FACING Y(degree) OUTWARD IF SIGN
GALVANIZED BOLT WITH IS V9THIN 30 FEFT OF ROApWAY
GALVANIZED WASHERS. SIGN FACE ORIENTATION
2" SQUARE.
METAL POST z
v
00
RYP
o T P F N H SIGN POST
LOWER SOUAIR
TUBE)
0 0
W
In FINISHED hm o
I a UN
LINE d, LOWER SIGN 5/16" (IN CORNER BOLT
-0 POST SUPPORT / 318" (IN) FLANGED
_ SHOULDER BOLT WITH
NUT AND WASHERS ti
2 REQUIRED (TYP.)
` z `B_O-LT STOP
(I
C
>` TYPE ST-4 SIGN SUPPORT
t
LOWER SIGN POST SUPPORT - 2,25"
(IN), 7-CAGE. HOT -DIP GALV.,
IN HEAVY-DUTYANCHOR
I M.
COMMERCIAL CONCRETE
MOUNTING ON METAL POST
SIGN MOUNTING ON SINGLE STD. PLAN- 129
®� PUBLIC WORKS METAL (ADOPTED) POST APPROVED: d
DEPARTMENT y"V
-- 6- G_ Harr
CONSTRUCTION RECORD
DRAWINGS
THIS CONSTRUCTION RECORD DRAWING IS A COPY
OF THE APPROVED CONSTRUCTION DRAWINGS
PREPARED BY TRANSPO GROUP USA, INC. AND
HAS BEEN EDITED TO REFLECT ASBUILT
CONDITIONS. THE INFORMATION PROVIDED ON
THESE RECORD DRAWINGS IS A COMBINATION OF
FIELD SURVEY INFORMATION AND DOCUMENTED
FIELD REVISIONS.
:1
transpogroup
WHAT TRANSPORTATION CAN BE.
12131 113TH AVENUE NE, SUITE 203 (TEL) 425 821-3665
KIRKLAND, WASHINGTON 98034 (FAX) 425 825-8434
DocuSign Envelope ID: 5D308A1A-204D-48E8-BB23-8A2834BB565E
SHIM TO PLUMB
SHIM TO PLUMB
SEE NOTE 3 SEE NOTE 3
�H4 HOOPS
NOTES
1. WHERE FOUNDATION PAD IS LOCATED WITHIN A SIDEWALK, CONSTRUCT
PAD TOP FLUSH WITH SIDEWALK GRADE, OMITTING CHAMFER WHERE
TOP AND SIDEWALK ABUT. MOUNT TOP SHALL BE FINISHED BY A
CONCRETE CONTRACTOR AND SHALL MEET THE REQUIREMENTS OF
SECTION 8-14.3 IN THE WSDOT STANDARD SPECIFICATIONS.
2. PAD MOUNT DESIGN IS TYPICAL.
3. PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET,
4. ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET
MANUFACTURER AND SUBMITTED TO THE ENGINEER FOR APPROVAL.
5. CONDUIT SIZES/QUANTITIES FOR THE CONTROLLER AND CONTACTOR
CABINETS SHALL BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE
2" SPARE CAPPED OUT PAST THE FOUNDATION.
6. CONCRETE CLASS PER STD PLAN 135.
7. 2" CONDUIT SHALL BE PLACED FROM THE COMBINED BBS/CONTACTOR
TO THE CONTROLLER CABINET.
8. EACH CABINET SHALL HAVE A %" DIAMETER PLASTIC DRAIN PIPE.
9. LOCATE CONDUITS CENTRALLY WITHIN THE CABINETS.
�1.
0. WHEN ALL THREE CABINETS ARE TO BE INSTALLED AND SPACE
ALLOWS, A COMBINED FOUNDATION SHALL BE USED.
WOODEN SHIMS SHALL NOT BE USED
12. GROUNDING SHALL BE PER WSDOT STANDARD PLAN J-60.05, SHEET 3.
SHIM TO PLUMB
ES�SEE NOTE 3
2"
I • _ JE: i II
6" MIN Ld � 14 1" TO 2"
FRONT VIEW
3 - #4 REINFORCING BAR (EQUAL SPACES)
3/8" DIAMETER PLASTIC DRAIN (ONE PER CABINET)
SEE NOTE 5
SEE NOTE 7
tO 3/8" DIAMETER PLASTIC DRAIN
SEE NOTE 5
N�
o�
�amw+
IF
o
�
HORIZONTAL
COMBINED FOUNDATION
REINF. BAR DIAGRAM
6 PIECES
#4 HOOPS 3 - #4 REINFORCING BAR
BBSI (EQUAL SPACES)
CONTROLLER CONTACTOR
CABINET CABINET
10" WIDTH 5„ WIDTH 10"
+1" +2"
PLAN VIEW
COMBINED CONTROLLER /BBS/CONTACTOR FOUNDATION
ti o CABINET FOUNDATION STD. PLAN - 126.2
PUBLIC WORKS DETAILS T
OVED:DEPARTMENT 3/13/2019 1 4
DATE
F=
T-420004
GMD RENTON
Know what's below.
Call before you dig.
52038
;rsTER���,ti� CITY OF RENTON MAY 2022
NA1 �� h�Iti� AS-BUILTS ILLUMINATION DETAILS
L03
SHEET
3
OF
10
SHEETS