Loading...
HomeMy WebLinkAboutT-4200040 0 N I T- 0 rr DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959 z: :7 OO "' V C) & LU LU OOOO OOOO t0 hl I-(D2m W ZzCD0> W W pH -1 1: W W m=w mm: I- Z QQm1­->AUUUW=aO ~AQ 0z0w HZZHaWH- LU � _ Wm w=LLmHLLF OWHW O Z�W 9 x - J z Z W m � V Z LL O = W U-LU_j Z 0LU U)Z 0 ZwgO� LU= �o wci) JW�=o Hz 2Z LU > W W(1) H 2 W H H g F- W Q Z _ J Q W U J j= > Q m U Q w U In C9 z Of LU W IY �3: 0 = �J 1-H av r(n z z 0 Of Q Go OO �L EO ZJ~ F-m F- W0a0 O a U U N N z } d N Y Q z Q 10�a. ~ 0 LUO LL In w O z ►�i w M I-i Q a w 0 z_ 0 N O SERVICE CABINET App gg PLAN - 122.1 ®� PDEPAR DEPAUBLIC RTMENT Martin 11 astUCfyj8/2021 1 4:? FNS� DATE DocuSign Envelope ID: 5D308A1A-204D-48E8-BB23-8A2834BB565E GENERAL NOTES: 1. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 2. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 3. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS(I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). 4. ALL NEW TRAFFIC SIGNALS SHALL BE CONSTRUCTED WITH FIBER COMMUNICATION CONNECTION TO CITY OF RENTON TRANSPORTATION FIBER OPTIC NETWORK. 5. ALL TRANSPORTATION ASSETS THAT ARE TO BE REMOVED AND THEN REINSTALLED AT A LATER DATE DURING CONSTRUCTION SHALL BE RE -INSTALLED TO CURRENT STANDARDS. 6. SIGNAL POLE, LUMINAIRE, AND CABINET FOUNDATIONS SHALL BE CLASS 4000P CONCRETE. 7. ALL PROPOSED SIGNAL POLE FOUNDATIONS AND EXISTING MODIFIED SIGNAL POLE FOUNDATIONS SHALL INCLUDE A CONCRETE PAD AROUND THE FOUNDATION. PROPOSED OR EXISTING SIDEWALK SHALL BE CONSIDERED PART OF THE FOUNDATION PAD. FOUNDATION PAD SHALL BE AT LEAST 2 FEET OFFSET FROM THE SIGNAL POLE FOUNDATION, AS SPACE ALLOWS. 8. WHEN THE TRAFFIC SIGNAL IS OPERATIONAL, VEHICLE DETECTION SHALL BE MAINTAINED AND REMAIN FUNCTIONAL. NEW PERMANENT/TEMPORARY VIDEO DETECTION SHALL BE INSTALLED AND OPERATIONAL PRIOR TO DESTROYING ANY EXISTING VEHICLE DETECTION. 9. ALL TRAFFIC SIGNAL SYSTEMS, ILLUMINATION SYSTEMS, OR OTHER ELECTRICAL TRANSPORTATION SYSTEMS ARE SUBJECT TO INSPECTION BY CITY OF RENTON TRANSPORTATION OPERATIONS MAINTENANCE DEPARTMENT PRIOR TO FINAL ACCEPTANCE. CONTRACTOR TO COORDINATE INSPECTION WITH THE TRANSPORTATION OPERATIONS MAINTENANCE MANAGER OR OTHER TRANSPORTATION OPERATIONS MAINTENANCE REPRESENTATIVE. G PUBLIC WORKS DEPARTMENT 1 TRANSPORTATION NOTES STD. PLAN - 135 -ArrPRGAZovED: 3/13/2019 1 4 DATE 1 DocuSign Envelope ID: F09FD439-BD22-4654-ABD3-E560AA1F5959 UUMPOINLIN"1' SCHLllULL OMETERBASE: 200 AMP, 4 JAW, MANUAL BYPASS, B-LINE U264 W/ STH JAW AT 9:00 POSITION O PANELBOARD: 120/240 VAC, 125 AMP COPPER BUS, 1 PHASE, 3 WIRE, 18 CKT, IOK AIC MAIN BREAKER: 200 AMP FRAME, 200 AMP TRIP, 2 POLE, EATON ED2200 BOLT -ON BRANCH BREAKERS, EATON TYPE BAB: 2 - 20/2 ILLUMINATION A, B 1 -20/1 ITS 1 - 20/1 GROUND FAULT RECEPTACLE 1 - 40/1 SIGNAL (IF PRESENT) 1 - 40/1 AUXILLIARY SIGNAL (IF PRESENT) 2 - 60/2 SMALL CELL BRANCH 1 - 1511 CONTROL 3 - 20/1 SPARE O CONTACTOR: NEMA LIGHTING RATED, 30 AMP 4 POLE, 120 VAC COIL, SQD 891ODPA34VO2 -I REQUIRED 40 PHOTO ELECTRIC CELL: 1800 WATT, 120 VAC, TWIST LOCK, ALR #SST-IES-UL MOUNTED INSIDE CABINET BEHIND WIREGLASS WINDOW 50 PHOTO -CELL BYPASS SWITCH: SPDT, 15 AMP, RATED (UP TO) 277 VAC (FED THROUGH TERMINAL BLOCK) OGROUND FAULT RECEPTACLE: 20 AMP, 125 VAC, DUPLEX CABINET: CONSTRUCTION: NEMA TYPE 3R, OUTDOOR PADMOUNT, 1/8" 5052-H32 ALUMINUM CONSTRUCTION, OPEN BOTTOM FRAMED WITH 2" ANGLE, 2 SCREENED AND GASKETED VENTS, REMOVABLE EQUIPMENT MOUNTING PAN, CABINET GROUND WITH MINIMUM BONDING WIRE TO NEUTRAL DOORS: HEAVY-DUTY CONCEALED HINGES (LIFT-OFF TYPE),STAINLESS STEEL VAULT HANDLES WITH ROLLER RODS THAT PROVIDE 3-POINT COMPRESSION ON CLOSED CELL NEOPRENE GASKET, "BEST" LOCK ON LOWER DISTRIBUTION DOOR WITH CARD HOLDER, PADLOCKABLE UPPER METER DOOR WITH POLISHED SAFETY GLASS WINDOW DEADFRONT: HINGED AND SECURED WITH QUARTER -TURN FASTENERS FINISH: MILL FINISH ALUMINUM 1 - REQUIRED UL LISTED PER STANDARD #508A "SUITABLE FOR USE AS SERVICE ENTRANCE" NOTE: 1. SIGNAL BREAKER(S) SHALL BE ADDED WHEN APPLICABLE ��Y 0 SERVICE CABINET NOTES pLAN - 122.2 PUBLIC WORKS ApPROV D: A DEPARTMENT Martin aStuCfj*8/2021 1 4 NSA DATE . a.. MOEN ice M £ 1 /4" LOAD FUSE LINE 1 /4" r 1/8" QO O 1/S" CUTTING RINGS FUSE KIT r ► �o��rir VV T C 3F`LIt r- SPLICE KIT FUSE KIT & SPLICE KIT DETAILS 1 p ADOPTED CITY OF RENTON +LL STANDARD PLANS IST DATE: 04/04 ...ram ..-......,... .... nwr NA1/F, In1I CP PArF•.In13 DATE REVISION BY DATE DESIGNED BY MRW 05/12/2022 0 RECORD DRAWINGS KLW 8/27/2024 DRAWN BY MRW 05/12/2022 REVIEWED BY CAC 05/12/2022 DocuSign Envelope ID: 5D308A1A-204D-48E8-BB23-8A2834BB565E CONDUIT ENTRANCE AREA k PLAN VIEW SIZE TO FIT SIZE TO FIT CABINET CABINET 6" 6" I' -GRADE LEVEL N a FRONT VIEW SIDE VIEW ELECTRICAL SERVICE CABINET FOUNDATION ti o PUBLIC WORKS DEPARTMENT BAND OR SHIM TO PLUMB SEE NOTE 3 o #4 HOOPS fiIIT #4 BARE11T CORNER 6" MIN 1" TO 2" 3/8" DIAMETER PLASTIC DRAIN SIDE VIEW CABINET DEPTH + 2" H - - - - - #4 BAR EACH + i AP I #4 CORNER m +III _HOOPS Li Li PLAN VIEW CONTROLLER CABINET FOUNDATION NOTES PER STD PLAN 126.2 CABINET FOUNDATION DETAILS STD. PLAN - 126.1 $OVED: 3/13/2019 I DATE NOTES 1. DIMENSIONS FOR THE PARTS USED TO ASSEMBLE THE BASE CONNECTIONS ARE INTENTIONALLY NOT SHOWN. BASE CONNECTIONS ARE PATENTED. MANUFACTURED PRODUCTS THAT ARE IN COMPLIANCE WITH NCHRP 350 CRASH TEST CRITERIA. THE BASE CONNECTION DETAILS ARE SHOWN ON THIS PLAN ONLY TO ILLUSTRATE HOW THE PARTS ARE ASSEMBLED. 2. A 2" (IN) POST WITH A 2 1/4" (IN) PSST ANCHOR OR A 2 1/4" (IN) POST WITH A 2 1/2" (IN) PSST ANCHOR MAY BE SUBSTITUTED. SEE CONTRACT PLANS. 3. PERFORATED SQUARE STEEL POST SHALL MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATION 9-06. 4. USE ONLY BASE CONNECTION MANUFACTURER SUPPLIED HARDWARE THAT MEETS THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS 9-06 AND 9-28. MOUNTING ON EXISTING METAL POLE OR LUMINAIRE EDGE OF TRAVELED ROAOWAY 90 30'-� 4" MIN. T EDGE OF bIGN FOR REFLECTORIZED SIGNS: MOUNT 5/16"x2-1 FACING Y(degree) OUTWARD IF SIGN GALVANIZED BOLT WITH IS V9THIN 30 FEFT OF ROApWAY GALVANIZED WASHERS. SIGN FACE ORIENTATION 2" SQUARE. METAL POST z v 00 RYP o T P F N H SIGN POST LOWER SOUAIR TUBE) 0 0 W In FINISHED hm o I a UN LINE d, LOWER SIGN 5/16" (IN CORNER BOLT -0 POST SUPPORT / 318" (IN) FLANGED _ SHOULDER BOLT WITH NUT AND WASHERS ti 2 REQUIRED (TYP.) ` z `B_O-LT STOP (I C >` TYPE ST-4 SIGN SUPPORT t LOWER SIGN POST SUPPORT - 2,25" (IN), 7-CAGE. HOT -DIP GALV., IN HEAVY-DUTYANCHOR I M. COMMERCIAL CONCRETE MOUNTING ON METAL POST SIGN MOUNTING ON SINGLE STD. PLAN- 129 ®� PUBLIC WORKS METAL (ADOPTED) POST APPROVED: d DEPARTMENT y"V -- 6- G_ Harr CONSTRUCTION RECORD DRAWINGS THIS CONSTRUCTION RECORD DRAWING IS A COPY OF THE APPROVED CONSTRUCTION DRAWINGS PREPARED BY TRANSPO GROUP USA, INC. AND HAS BEEN EDITED TO REFLECT ASBUILT CONDITIONS. THE INFORMATION PROVIDED ON THESE RECORD DRAWINGS IS A COMBINATION OF FIELD SURVEY INFORMATION AND DOCUMENTED FIELD REVISIONS. :1 transpogroup WHAT TRANSPORTATION CAN BE. 12131 113TH AVENUE NE, SUITE 203 (TEL) 425 821-3665 KIRKLAND, WASHINGTON 98034 (FAX) 425 825-8434 DocuSign Envelope ID: 5D308A1A-204D-48E8-BB23-8A2834BB565E SHIM TO PLUMB SHIM TO PLUMB SEE NOTE 3 SEE NOTE 3 �H4 HOOPS NOTES 1. WHERE FOUNDATION PAD IS LOCATED WITHIN A SIDEWALK, CONSTRUCT PAD TOP FLUSH WITH SIDEWALK GRADE, OMITTING CHAMFER WHERE TOP AND SIDEWALK ABUT. MOUNT TOP SHALL BE FINISHED BY A CONCRETE CONTRACTOR AND SHALL MEET THE REQUIREMENTS OF SECTION 8-14.3 IN THE WSDOT STANDARD SPECIFICATIONS. 2. PAD MOUNT DESIGN IS TYPICAL. 3. PLACE A SILICONE SEAL BETWEEN THE FOUNDATION AND CABINET, 4. ANCHOR BOLTS AND THEIR SPACING TO BE SUPPLIED BY CABINET MANUFACTURER AND SUBMITTED TO THE ENGINEER FOR APPROVAL. 5. CONDUIT SIZES/QUANTITIES FOR THE CONTROLLER AND CONTACTOR CABINETS SHALL BE INSTALLED PER THE CONTRACT PLANS, PLUS ONE 2" SPARE CAPPED OUT PAST THE FOUNDATION. 6. CONCRETE CLASS PER STD PLAN 135. 7. 2" CONDUIT SHALL BE PLACED FROM THE COMBINED BBS/CONTACTOR TO THE CONTROLLER CABINET. 8. EACH CABINET SHALL HAVE A %" DIAMETER PLASTIC DRAIN PIPE. 9. LOCATE CONDUITS CENTRALLY WITHIN THE CABINETS. �1. 0. WHEN ALL THREE CABINETS ARE TO BE INSTALLED AND SPACE ALLOWS, A COMBINED FOUNDATION SHALL BE USED. WOODEN SHIMS SHALL NOT BE USED 12. GROUNDING SHALL BE PER WSDOT STANDARD PLAN J-60.05, SHEET 3. SHIM TO PLUMB ES�SEE NOTE 3 2" I • _ JE: i II 6" MIN Ld � 14 1" TO 2" FRONT VIEW 3 - #4 REINFORCING BAR (EQUAL SPACES) 3/8" DIAMETER PLASTIC DRAIN (ONE PER CABINET) SEE NOTE 5 SEE NOTE 7 tO 3/8" DIAMETER PLASTIC DRAIN SEE NOTE 5 N� o� �amw+ IF o � HORIZONTAL COMBINED FOUNDATION REINF. BAR DIAGRAM 6 PIECES #4 HOOPS 3 - #4 REINFORCING BAR BBSI (EQUAL SPACES) CONTROLLER CONTACTOR CABINET CABINET 10" WIDTH 5„ WIDTH 10" +1" +2" PLAN VIEW COMBINED CONTROLLER /BBS/CONTACTOR FOUNDATION ti o CABINET FOUNDATION STD. PLAN - 126.2 PUBLIC WORKS DETAILS T OVED:DEPARTMENT 3/13/2019 1 4 DATE F= T-420004 GMD RENTON Know what's below. Call before you dig. 52038 ;rsTER���,ti� CITY OF RENTON MAY 2022 NA1 �� h�Iti� AS-BUILTS ILLUMINATION DETAILS L03 SHEET 3 OF 10 SHEETS