0 0 N I I 0 F_ GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH RENTON STANDARD SPECIFICATIONS, RENTON STANDARD PLANS, AND THE CONTRACT, UNLESS OTHERWISE NOTED. A COPY OF THESE DOCUMENTS SHALL BE ON SITE DURING CONSTRUCTION. 2. A COPY OF THE APPROVED PLAN SHALL BE ON SITE DURING CONSTRUCTION. 3. ALL PERMITS REQUIRED FOR WORK WITHIN THE PUBLIC RIGHT OF WAY MUST BE OBTAINED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 4. THE LOCATION OF EXISTING FEATURES AND UTILITIES SHOWN WITHIN THESE PLANS ARE APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCING LIGHTING WORK. NOT ALL EXISTING FEATURES AND UTILITIES MAY BE SHOWN. 5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT UTILITY AGENCIES 48 HOURS PRIOR TO COMMENCING WORK AND SHALL COORDINATE WITH ALL AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO EXISTING UTILITIES RESULTING FROM CONSTRUCTION ACTIVITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AGENCY IMMEDIATELY UPON DAMAGE AND SHALL BE RESPONSIBLE FOR REPLACING DAMAGED EQUIPMENT TO THE SATISFACTION OF THE AFFECTED UTILITY AGENCY. 6. THE CONTRACTOR SHALL SALVAGE AND DELIVER ALL EXISTING SIGNAL EQUIPMENT SPECIFIED FOR REMOVAL BACK TO CITY OF RENTON, UNLESS OTHERWISE NOTED IN WRITING BY THE ENGINEER. 7. THE LOCATIONS OF PROPOSED CONDUITS AND JUNCTION BOXES SHOWN IN THESE PLANS ARE GRAPHICAL REPRESENTATIONS ONLY. THE CONTRACTOR SHALL FIELD VERIFY FINAL LOCATIONS WITH THE ENGINEER PRIOR TO INSTALLATION. 8. THE CONTRACTOR SHALL FIELD VERIFY FINAL LOCATIONS OF ALL PROPOSED FOUNDATIONS WITH THE ENGINEER PRIOR TO EXCAVATION. 9. PROPOSED JUNCTION BOXES LOCATED WITHIN SIDEWALKS AND CURB RAMPS SHALL BE EQUIPPED WITH SLIP -RESISTANT LIDS. 10. TYPE 1 AND TYPE 2 JUNCTION BOXES SHALL BE INSTALLED PER WSDOT STANDARD PLAN J-40.10. 11. THE CONTRACTOR SHALL LABEL ALL CONDUCTORS FOR SIGNAL EQUIPMENT WITHIN EACH JUNCTION BOX. 12. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THIS PLAN. AS THE FIRST ORDER OF BUSINESS, THE CONTRACTOR SHALL POTHOLE EACH LOCATION TO CONFIRM THAT THERE ARE NO CONFLICTS WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10-FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED STREETLIGHT POLES PRIOR TO CONSTRUCTION. ADDITIONAL CLEARANCE MAY BE REQUIRED AS DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 13. THE CONTRACTOR SHALL REMOVE ALL EXISTING CONDUCTORS ASSOCIATED WITH EXISTING SIGNAL EQUIPMENT SPECIFIED FOR REMOVAL, UNLESS OTHERWISE NOTED. CAP AND ABANDON EXISTING UNUSED CONDUIT. REMOVE PORTIONS OF ABANDONED CONDUIT WHERE IN CONFLICT WITH NEW CONDUIT, UNLESS OTHERWISE NOTED. 14. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I.E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS). 15. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 16. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS). S GRADY WAY CONSTRUCTION NOTES O INSTALL PEDESTRIAN SIGNAL STANDARD (TYPE PS) AND FOUNDATION PER CITY OF RENTON STANDARD PLAN 131. INSTALL ONE APS PUSHBUTTON ASSEMBLY AND ONE PEDESTRIAN SIGNAL HEAD (TYPE D MOUNT) ON POLE PER WSDOT STANDARDS PLAN J-20.26 AND J-75.10. O INSTALL ACCESSIBLE PEDESTRIAN PUSHBUTTON POST (PPB) AND FOUNDATION PER WSDOT STANDARD PLAN J-20.10. INSTALL ONE APS PUSHBUTTON ASSEMBLY ON POST PER WSDOT STANDARD PLAN J-20.26. O INSTALL ACCESSIBLE PEDESTRIAN PUSHBUTTON POST (PPB) WITH CURB BASE AND FOUNDATION PER WSDOT STANDARD PLAN J-20.11. INSTALL TWO APS PUSHBUTTON ASSEMBLIES ON POST PER WSDOT STANDARD PLAN J-20.26. ® INSTALL PEDESTRIAN SIGNAL STANDARD (TYPE PS) AND FOUNDATION PER CITY OF RENTON STANDARD PLAN 131. INSTALL ONE APS PUSHBUTTON ASSEMBLY AND ONE PEDESTRIAN SIGNAL HEAD (TYPE D MOUNT) ON POLE PER WSDOT STANDARDS PLAN J-20.26 AND J-75.10. O5 REMOVE EXISTING PUSHBUTTON SERVING EAST/WEST CROSSING AND REPAIR HOLES IN POLE WITH WATERTIGHT SEAL AS APPROVED BY THE ENGINEER. © REPLACE EXISTING JUNCTION BOX WITH TYPE 2 JUNCTION BOX. O7 ROUTE NEW CONDUITS) AND CONDUCTORS INTO EXISTING JUNCTION BOX. ® REMOVE EXISTING LOOP WIRES BACK TO EXISTING RETURN CABLE. REMOVE UNUSED RETURN CABLES BACK TO SIGNAL CONTROLLER CABINET. O9 ADJUST JUNCTION BOX TO FINISHED GRADE. 10 PROTECT EXISTING POLE TO REMAIN. 11 COORDINATE WITH CITY OF RENTON PUBLIC WORKS/TRANSPORTATION ENGINEERING TO SET VIDEO DETECTION ZONES. 12 INSTALL VIDEO DETECTION CAMERA ON SIGNAL MAST ARM PER CITY OF RENTON STANDARD PLAN 140. LOCATION SHALL BE APPROVED BY CITY OF RENTON PUBLIC WORKS/TRANSPORTATION ENGINEERING PRIOR TO INSTALLATION. • -• • 20 .• DESIGNED BY DRAWN BY REVIEWED BY DATE MRW 05/12/2022 MRW 05/12/2022 CAC 05/12/2022 � • T(UG) —I _,�Lo�' / /�wTw—w—w--tom-"" --------- — _. �w �LVL w—w - w—w w =w=w=w— VL, I 0 0 G/ --12 G CII -------------------- ------- ------- ---------- - --- ---- TT 4_3 no P�68 � Y�l 7-- P(UG) f I P(UG) - - P(UG) I P(UG) 8 REVISION BY DATE IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING TRANSPORTATION OPERATIONr_1 N JChavez 05/17/2022 [CBarnes 05/17/2022 — 14+00 - L_� - transpogroulo AUF WHAT TRANSPORTATION CAN BE. LEGEND DESCRIPTION RIGHT-OF-WAY CONDUIT CONSTRUCTION NOTE SIGNAL POLE CONSTRUCTION NOTE WIRE NOTE SIGNAL POLE AND MAST ARM PEDESTRIAN SIGNAL STANDARD PEDESTRIAN PUSHBUTTON POST APS PEDESTRIAN PUSHBUTTON (PPB) ASSEMBLY PEDESTRIAN SIGNAL HEAD VEHICLE DETECTION LOOP TYPE 1 JUNCTION BOX TYPE 2 JUNCTION BOX SIGNAL CONTROLLER CABINET ELECTRICAL SERVICE CABINET EXISTING P(UG) P(UG) P(UG) P(UG) PROPOSED WIRING SCHEDULE A# RACEWAY CONDUIT SIZE* VEH DIET 2C(SH) EVP DIET 3C(SH) PPB 2C(SH) VIDEO VDCC CABLE VEH/PED 5C ILLUM #8 OTHER NO. 1 2" SCH40 1 1 2 1 " SCH40 1 3 EX 3" 4 (EX) 1 (EX) 2 4 (EX), 1 4 EX 3" 4 (EX) 2 (EX) 2 8 (EX), 1 5 EX 2" 5 (EX) 2 1 (EX) 6 EX 4" 4 (EX) 3 (EX) 2 1 (EX) 12 (EX), 1 7 EX 2" 4 (EX) 1 1 8 EX 3" 4 (EX) 1 (EX) 1 1 3 (EX), 1 2 (EX) 9 EX 4" 6 (EX) 1 (EX) 1 1 3 (EX), 1 10 EX 2" 2 (EX) 1 3 (EX) 11 1.5" SCH40 2 *ALL CONDUIT SHALL BE PVC AND SHALL CONTAIN A GROUND WIRE EQUAL IN SIZE TO THE LARGEST CONDUCTOR (MINIMUM NO. 8) UNLESS OTHERWISE NOTED. NEW 0 T-420005 GMD RENTON I Know what's below. Call before you dig. TS 01 SHEET 5 OF 10 SHEETS 12131 113TH AVENUE NE, SUITE 203 (TEL) 425 821-3665 KIRKLAND, WASHINGTON 98034 (FAX) 425 825-8434 �s°�R CITY OF RENTON NA TRAFFIC SIGNAL PLAN 0 MAY 2022