Loading...
HomeMy WebLinkAboutMFP22006503.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP22006503 IVR Number: 22006503 Permit Information Permit Name: Century Link Permits Address/Location:12/16/2022Application Date:7224000580Parcel Number: 332 PARK AVE N Permit Type:12/22/2022Issue Date:Franchise Permit Work Class:12/22/2023Expiration Date:Minor Utility Job Number: N.995732Franchise Type:Telephone Description: Lumen to place new aerial splice case on P0 and P6, and remove aerial copper from P1, P2, P3, P4, P5 and move underground to existing conduit Contacts Name Address PhoneTypeBilling Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549ApplicantX Jesse Patjens CenturyLink / Lumen 23315 66th Ave S Kent, WA 98032 Contact Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549Contact Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering Northsky Communications Tawnya Longfellow 22517 88th ave S Kent/WA 98031 Lumen to place new aerial splice case on P0 and P6, and remove aerial copper from P1, P2, P3, P4, P5 and move underground to existing conduit. N.995732 332 Park Ave N 1/16/23 2/16/23 425 615 7121 MFP22006503 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 12/22/2022 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Austin Sweeney Austin Sweeney 12/16/2022 Date: 12/2/2022 Author: Sharon Martos, Traffic Control Supervisor Project: N.995732 C.45 CERT: TCS # 012843 Designed for LUMEN: By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Arrowboard (Chevron) Cone truck P UPO Work Area TRAFFIC CONTROL PLAN JOB # N.995732 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 NOT TO SCALE Sharon Martos Project # N.995732 C.45Designed for LUMENSharon MartosApproved 12/2/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com NPARK AVE N @ N 3RD ST AERIAL REMVL SHEET 1 Comments: REMOVE AERIAL. RIGHT LANE CLOSURE.MOVING OPERATION. WORK TRUCK WILL TRAVEL WITH TRAFFIC. UPO WILL ASSIST IN LIGHTED INTERSECTION. SPEEDLIMIT 30 N 2ND STPELLY AVE N PARK AVE N N 3RD STWELLS AVE N ONEWAYR6-2RROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bW20-7aRIGHT LANECLOSEDAHEADW20-5ROADWORKAHEADW20-1ROADWORKAHEAD W20-1 BE PREPAREDTO STOP W20-7b ROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bW20-7aROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bX X X X 100' 100' 200' 200'200' 200' 200' 200' 200'150'P0 P3 P SEE SHEET 2www.invarion.com MFP22006503 Date: 12/2/2022 Author: Sharon Martos, Traffic Control Supervisor Project: N.995732 C.45 CERT: TCS # 012843 Designed for LUMEN: By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Cone truck P UPO Work Area TRAFFIC CONTROL PLAN JOB # N.995732 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60NOT TO SCALE Sharon Martos Project # N.995732 C.45Designed for LUMENSharon MartosApproved 12/2/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com NPARK AVE N @ N 4TH ST AERIAL REMVL SHEET 2SPEEDLIMIT 30 PARK AVE N N 4TH STX X X SEE SHEET 1P6 GARDEN AVE N P4 ROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bW20-7a ROADWORKAHEAD W20-1 BE PREPAREDTO STOP W20-7b ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEAD W20-1BE PREPAREDTO STOPW20-7bW20-7aONEWAYR6-2L200' 200' 200'200' 100'ROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7b100' P Comments: REMOVE AERIAL. RIGHT LANE CLOSURE. MOVING OPERATION.WORK TRUCK WILL TRAVEL WITH TRAFFIC.UPO WILL ASSIST IN LIGHTED INTERSECTION. www.invarion.com MFP22006503 Date: 12/2/2022 Author: Sharon Martos, Traffic Control Supervisor Project: N.995732 C.45 CERT: TCS # 012843 Designed for LUMEN: By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Arrowboard (Chevron) Cone S Spotter truck Work Area TRAFFIC CONTROL PLAN JOB # N.995732 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 NOT TO SCALE Sharon Martos Project # N.995732 C.45Designed for LUMENSharon MartosApproved 12/2/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com NPARK AVE N @ N 3RD ST P0 SPLICE CASE RIGHT LANE CLOSURESPEEDLIMIT 30 N 2ND STPELLY AVE N PARK AVE N N 3RD STONEWAYR6-2RROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5ROADWORKAHEADW20-1ROADWORKAHEAD W20-1 X 200'200'200'150'P0 SEE SHEET 2ROADWORKAHEADW20-1ROADWORKAHEADW20-1S WORK AREA10 X 190 Comments: ACCESS P0 AND PLACE SPICE CASE. EAST SIDE PARK AVE N, SOUTH OFN 3RD ST. RIGHT LANE CLOSURE.SIDEWALK ACCESSIBLE. SPOTTER WILL ASSIST PEDESTRIANS. www.invarion.com MFP22006503 Date: 12/2/2022 Author: Sharon Martos, Traffic Control Supervisor Project: N.995732 C.45 CERT: TCS # 012843 Designed for LUMEN: By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Cone S Spotter truck Work Area TRAFFIC CONTROL PLAN JOB # N.995732 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60NOT TO SCALE Sharon Martos Project # N.995732 C.45Designed for LUMENSharon MartosApproved 12/2/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com NPARK AVE N @ N 4TH ST P6 SPLICE CASE SHOULDER WORK Comments: ACCESS P6 AND PLACE SPICE CASE. EAST SIDE PARK AVE N, NORTH OF N 4TH ST.SHOULDER WORK. SIDEWALK ACCESSIBLE.SPOTTER WILL ASSIST PEDESTRIANS. SPEEDLIMIT 30 PARK AVE N N 4TH STX P6 GARDEN AVE N ROADWORKAHEAD W20-1 ROADWORKAHEADW20-1ONEWAYR6-2LWORK AREA10 X 100ROADWORKAHEADW20-1SHOULDERWORKW21-5200' S www.invarion.com MFP22006503 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.5100000000”NVICINITY MAPREVISION # SHEET # REASON FOR REVISION REVISED BY DATEREVISION 1 1, 3 & 4 ADDITION ON 4 POLES # 7-10 & POLE BOXES SL 05/09/22REVISION 2 1, 3 & 4 NOT REMOVING P-0 & P-1, NOW KEEPING P-1, NEW P-BOX INFO, CUSTOMER PROVIDED CONDUIT FOR UG, NEW SOW & NOTE SL 05/20/22REVISION 3 1, 3 & 4 NOW REMOVING P-1, NOW RISER UP P-0, UPDATE SOW & NOTE SL 11/30/22SCOPE OF WORK:PSE TO REMOVE 5 PSE POLES (P01-P05), LUMEN TO TRANSFER ALL AERIAL COPPER FACILITIES TO UNDERGROUND. CUSTOMER HAS PLACEDCONDUIT ON THE EAST SIDE OF PARK AVE N. BACK ON 2017. @ POLE 0, PLACE AERIAL SPLICE CASE, NEW POLE RISER THEN RISER DOWN TOCUSTOMER'S PLACED CONDUIT. CONTINUE TO PLACE NEW FIBER TO POLE 6 LOCATION. @ POLE 6, PLACE NEW RISER THEN RISER UP & PLACENEW SPLICE CASE. NOTE: IF CUSTOMER PLACED CONDUIT DOES NOT REACH TO POLE 6 THE CUSTOMER WILL PLACE MORE CONDUIT FOR LUMEN.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 04/26/2223N5E17N.995732W26226RNTNWA01332 PARK AVE N.RENTON, WA 9805714RFIBER ENGINEER: NARRA LAMPHONE NO: (253) 458-6537EMAIL: narra.lam@lumen.comMFP22006503 TTEE CATV CATV CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L R/W R/W R/W P/L P/L B/C B/C B/C EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONHT-CL-YRPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSRMT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 04/26/2223N5E17N.995732W26226RNTNWA01332 PARK AVE N.RENTON, WA 9805724FIBER ENGINEER: NARRA LAMPHONE NO: (253) 458-6537EMAIL: narra.lam@lumen.comMFP22006503 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:RNOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYEDOR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITHREFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGHTS OF WAY AND/OREASEMENTS PRIOR TO CONSTRUCTION.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 04/26/2223N5E17N.995732W26226RNTNWA01332 PARK AVE N.RENTON, WA 9805734FIBER ENGINEER: NARRA LAMPHONE NO: (253) 458-6537EMAIL: narra.lam@lumen.comSEE SHEET 4 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EO P EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R /W R/W C/L C/L C/L C/L C /L C/L EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R /W N. 3rd STREETSIDEWALK25SPEEDLIMITONEWAYPARK AVE N.SIDEWALK SIDEWALK x x x x x x x x 30SPEEDLIMIT301PARCEL#7224000425247PARCEL#7224000340235PARCEL#7224000325PARCEL#7224000335PARCEL#7224000330250PARCEL#7224000280236PARCEL#7224000265232PARCEL#7224000260247PARCEL#7224000340240PARCEL#7224000270248PARCEL#7224000275STATIONPSEPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHERREMOVE COPPER OFF POLE & TRANSFER TO NEW 4"CONDUIT ALONG PARK AVE N.NEUTRAL = 30'4"004 = 25'4"005 = 24'4" & 22'4"318049-166178N/AA050944310+00STATIONPSEPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHERREMOVE COPPER OFF POLE & TRANSFER TO NEW 4"CONDUIT ALONG PARK AVE N.NEUTRAL = 31'9"SECONDARY = 30'4"004 = 22'8"005 = 26'5" & 23'5"NO # TAGSN/AA05094442N/A332PARK AVE N.PARCEL#7224000580SIDEWALK10' PARKING36'45'45'24'11'11'11'11'NOTE:CUSTOMER HAS PLACED CONDUIT ON THEEAST SIDE OF PARK AVE N. BACK ON 2017.SIDEWALK11'11'SIDEWALKSTATIONLUMENPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHEREXISTING FEEDER TO BE RE-LOCATEDNEUTRAL = 26'2"004 = 20'2"005 = 18'2"A0509445N/A7N/ANOTE:@ POLE 0, PLACE AERIAL SPLICE CASE,NEW POLE RISER THEN RISER DOWN TOCUSTOMER'S PLACED CONDUIT. CONTINUETO PLACE NEW FIBER TO POLE 6 LOCATION. x x x x x STATIONPSEPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHERPLACE SPLICE CASE/PLACE NEW RISER - RISER DOWN318036-166173N/AA05094420N/ANEUTRAL = 28'6"004 = 21'9"005 = 21'1", 20'3" & 17'0"MEUTRAL =28;6"MFP22006503 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:RNOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYEDOR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITHREFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGHTS OF WAY AND/OREASEMENTS PRIOR TO CONSTRUCTION.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 04/26/2223N5E17N.995732W26226RNTNWA01332 PARK AVE N.RENTON, WA 9805744FIBER ENGINEER: NARRA LAMPHONE NO: (253) 458-6537EMAIL: narra.lam@lumen.comSEE SHEET 3 EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R /W R/W R/W R/W N. 4th STREETSIDEWALKPARK AVE N.332PARK AVE N.PARCEL#722400058025SPEEDLIMITONEWAYSIDEWALK x x x x x x x x x x x x x x x SIDEWALK SIDEWALK 6' GRASS30SPEEDLIMIT 420PARCEL#7564600105401PARCEL#7224000695351PARCEL#7224000475337PARCEL#7224000470329PARCEL#7224000460323PARCEL#7224000450315PARCEL#7224000440STATIONPSEPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHERREMOVE COPPER OFF POLE & TRANSFER TO NEW 4"CONDUIT ALONG PARK AVE N.NEUTRAL = 28'9"004 = 23'0"005 = 21'9" & 18'8"318088-166180N/AA0509447N/A3STATIONPSEPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHERREMOVE COPPER OFF POLE & TRANSFER TO NEW 4"CONDUIT ALONG PARK AVE N.NEUTRAL = 28'2"004 = 22'9"005 = 21'9" & 18'8"318102-166180N/AA0509448N/A4STATIONPSEPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHERREMOVE COPPER OFF POLE & TRANSFER TO NEW 4"CONDUIT ALONG PARK AVE N.NEUTRAL = 32'1"004 = 22'3"005 = 25'4", 24'9" & 19'0"318166-166182N/AA0509451N/A5STATIONPSEPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHERPLACE NEW 4" RISER CONDUIT UP POLE, THEN ADDNEW SPLICE CASE & OVERLASH ON EXISTING COPPER .NEUTRAL = 32'4"004 = 26'1" ARM005 = 26'1" ARM & 22'2"NO # TAGS26'1"NO 'A' TAG0+006NOTE:@ POLE 6, PLACE NEW RISER THEN RISER UP &PLACE NEW SPLICE CASE. NOTE: IF CUSTOMERPLACED CONDUIT DOES NOT REACH TO POLE 6 THECUSTOMER WILL PLACE MORE CONDUIT FOR LUMEN.36'45'45'24'54'24'11'11'11'11'10'11'11'10'33'41'STATIONLUMENPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHEREXISTING FEEDER TO BE RE-LOCATEDNEUTRAL = 25'7"004 = 21'8"005 = 21'8"A0506450N/AN/A10STATIONPSEPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHEREXISTING FEEDER TO BE RE-LOCATEDNEUTRAL = 26'1"004 = 22'6"005 = 22'6"318096-166174N/AA0509449N/A9STATIONPSEPROPOSED HOAPOLE NUMBER(S) - LMN/PWR/OTHEREXISTING FEEDER TO BE RE-LOCATEDNEUTRAL = 25'8"005 = 21'9"318088-166174N/AA0509446N/A8NOTE:IF CUSTOMER PLACED CONDUIT DOES NOTREACH TO POLE 6 THE CUSTOMER WILLPLACE MORE CONDUIT FOR LUMEN.NOTE:PSE TO REMOVE PSE POLES (P01-P05),LUMEN TO TRANSFER ALL AERIAL COPPERFACILITIES TO UNDERGROUND.MFP22006503