EXISTING ASPHI
PAVEMENT
SAWCUT
(SEE NOTE 2)
ARTERIAL STREET MINIMUM
7" HMA (or ACP Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
RESIDENTIAL STREET MINIMUM
4" HMA (or ACP Class B)
(SEE NOTE 1), OVER
6" CRUSHED ROCK
NOTES:
1. MUST MATCH EXISTING THICKNESS IF GREATER.
2. SAWCUT SHALL BE POSITIONED 1' - 0" BEYOND EDGE OF
DAMAGED PAVEMENT.
3. THE INTENT OF THIS DESIGN IS TO DESCRIBE PAVEMENT
PLACEMENT AT 'THE GUTTER FACE. SEE STANDARD PLAN
FOR CEMENT CONCRETE CURBS.
F►'jIM11 IIIIIIIIIIIIIIIH2111111zE9Will
PUBLIC WORKS
I DEPARTMENT
W" [13mm] LETTERING
BOLTHOLES-3 PLCS EQUALLY SPACED 120'
DRA jN T APART ON 23 1/16" (586mm) DIA B.C.
S
® sT��
cQ
RENTON
AHEAD OF THE CURVE
DRAIN
(1) 1' (25mm)
DIA PICKHOLE COVER BOTTOM VIEW
1 114" [32mm] LETTERING
PLAN VIEW
O
25" DIA.
[635mm] [25mm]
3/4"
[79mm]
►� 8 2 1/2''
[22222mm] [84mm]
TYP
COVER SECTION VIEW
26 1/2' DIA
[673mm]
25 1/4" DIA
[641mm] 111161
[27mm]
F�NE.(IIMIEMN
DIA
E GASKET
6"
[152mm]
vs., 23 3/6" DIA CL OPEN
[16mm] [594mm]
27 5/15" DIA
[694mm]
34 1/8" DIA
[867mm]
FRAME SECTION VIEW
(3) BLT SOC. (ALLEN HEAD)
5/8"-11 X 1.5 SS
RUBBER WASHER
EON BOLTING DETAIL
1/4"
[6mm] 11/18"
[27mm]
1/8'
[3mm]
[R3mm]
GASKET GROOVE DETAIL
NOTES I
ALL COVERS SHALL BE LOCKING LID PER EASTJORDAN IRON WORKS INC. No. 3717C1
OR APPROVED EQUAL.
SM
'CY
* PUBLIC WORKS STORM ROUND FRAME AND COVER' PLAN - 204.50
DEPARTMENT
�N tp MARCH 2O08
PORTION OF: NE1/4, NE1/4, SECTION 19, T. 23N., R. 05E., W.M.
MIN MIN MIN MIN MIN
2" CLAS
*2" TO 6" C
OR C
6.5' MIN.
2" DEPTH OF
GRIND OR SAWCUT AND REMOVE
6.5' MIN.
1' 1' 2.5'
MIN MIN MIN MIN MIN
2" CLASS `B'
CRUSHED ROCK, FLOWAhL, I ILL
OR AS REQUIRED BY ENGINEER
* FOR MINIMUM STANDARDS, SEE DWG# HR-05,
SP PAGE H032
JOINTS IN FILTER FABRIC SHALL BE SPLICED
AT POSTS. USE STAPLES, WIRE RINGS, OR
EQUIVALENT TO ATTACH FABRIC TO POSTS.
6' MAX.
u
�
POST SPACING MAYBE INCREASED
TO 8' IF WIRE BACKING IS USED
OF CURB OR
OF PAVEMENT
;ENTER LINE OR
ANE LINE
S*
D SURFACING TOP COURSE
TYPICAL TRANSVERSE PATCH
FOR FLEXIBLE PAVEMENT
STY p ADOPTED
I6 CITY OF RENTON
STANDARD PLANS
i N LST DATE:02/05
DWG. NAME: H032-1 SP PAGE: H032.1
2N2" BY 14 Ga. WIRE OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
FILTER FABRIC
MINIMUM 4"x4" TRENCH
BACKFILL TRENCH WITH
NATIVE SOIL
2"x4" WOOD POSTS, STEEL FENCE
POSTS, REBAR, OR EQUIVALENT
NOTES
1. CONDITION OF USE
1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW.
ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE
AVAILABLE ON SITE.
30-100SIEVESIZE(0.60-0.15MM) FORSILTFILM
A05 (ASTM D4751)
50-100 SIEV E SIZE (0.3M.15MM) FOR OTHER FABRICS
WATER PERMITTIVITY(ASTM D491)
002 SEC^-1 MINIMUM
GRAB TENSILE STRENCHT(ASTM D4632)
180LBS. MIN. FOR EXTRASTRENGH FABRIC
100 LBS. MIN. FOR STANDARD STRENGHT FABRIC
GRABTENSILE ELONGATION (ASTM D4632)
30%MAX.
ULTRAVIOLATE RESISTANCE(ASTM D4355)
70%MIN.
2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST
SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE.
2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2HA V
2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE
IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT
FENCE.
3. MAINTENANCE STANDARDS
3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY.
3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND
THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP
SEDIMENT.
3.4. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH.
3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED.
STD. PLAN - 214.00
+ + PUBLIC WORKS SILT FENCE
DEPARTMENT
gN gyp$ MARCH 2O08
FRAME AND VANED GRATE
n�A 3p,
5 s•
6" OR 12"
ONE #3 BAR HOOP FOR 6" HEIGHT
TWO 93 BAR HOOPS FOR 12" HEIGHT
RECTANGULAR ADJUSTMENT SECTION
6�R NOTES
�
a Olt-
Q�
#3 BAR EACH CORNER F
#3 BAR EACH SIDE
#3 BAR EACH WAY
PRECAST BASE SECTION
#3 BAR EACH CORNER
18" MIN
#3 BAR HOOP
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR
12"
PLAIN CONCRETE
ALL METAL PIPE
15"
CPSSP*
12
(STD. SPEC. 9-05.20)
SOLID WALL PVC
15"
(STD. SPEC. 9-05.12(1))
PROFILE WALL PVC
15"
(STD. SPEC. 9-05.12(2))
* CORRUGATED POLYETHYLENE
STORM SEWER PIPE
1. As acceptable alternatives to the rebar shown in the PRECAST BASE
SECTION, fibers (placed according to the Standard Specifications), or
wire mesh having a minimum area of 0.12 square inches per foot shall
be used with the minimum required rebar shown in the ALTERNATIVE
PRECAST BASE SECTION. Wire mesh shall not be placed in the
knockouts.
2. The knockout diameter shall not be greater than 20". Knockouts shall
have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5"
minimum gap between the knockout wall and the outside of the pipe.
After the pipe is installed, fill the gap with joint mortar in accordance
with Standard Specification 9-04.3.
3. The maximum depth from the finished grade to the lowest pipe invert
shall be 5'.
4. The frame and grate must be installed with the flange down.
5. The Precast Base Section may have a rounded floor, and the walls may
be sloped at a rate of 1:24 or steeper.
6. The opening shall be measured at the top of the precast base section.
7. All pickup holes shall be grouted full after the basin has been placed.
B. All grade rings and castings shall be set in mortar in accordance with
Standard Specification 9-04.3.
SEE NOTE 1
ALTERNATIVE PRECAST BASE SECTION
�Y STD. PLAN - 200.00
�i► �� PUBLIC WORKS CATCH BASIN TYPE 1
O DEPARTMENT
MARCH 2O08
2 CITY REVISIONS TKB
1 CONSTRUCTION PERMIT SUBMITTAL TKB
NO. REVISION BY
T-92"
DEPTH: 3.52' TO IE OUT
44..
CONVERSION RISER
#45 EACH SIDE OF OPENING
ONE #4 BAR HOOP
�Y STD. PLAN - 200.40
PUBLIC WORKS CONVERSION RISER
O DEPARTMENT
MARCH 2O08
CONSTRUCTION RECORD DRAWING
I HEREBY DECLARE THAT TO THE BEST OF MY KNOWLEDGE THE
INFORMATION PRESENTED ON THESE PLANS REPRESENTS THE
AS -CONSTRUCTED CONDITIONS AS OF FEBRUARY 19, 2019. THE
INFORMATION SHOWN ON THESE RECORD DRAWINGS WAS COMPILED
FROM CONTRACTOR NOTES AND REDLINES.
NIKOLAI BOSSOFF 02/19/19
a
J
NAME
DATE
R-3929010
LICENSE # 29631
Q
APPROVED FOR CONSTRUCTION
P� B�
O F WASyI SS
SUBJECT TO ERRORS AND OMISSIONS
o o
BY: DATE:
FG
IST �631��Q ���
O�FSSIONAL
Q
BY: DATE:
E
Nick Bossoff Engineering, Inc.
U
191 NE Tari Lane
BY: DATE:
I�
Stevenson, WA 98648-4201
z
EXPIRES 7/2/19
Phone: (425) 881-5904
BY: DATE:
/0
SURVEYED:
PACE
SCALE:
1»=20'
VERTICAL: NAVD 1988
HORIZONTAL: NAD1983/1991
DATUM
1dDATE
Y
° CITY 0�
Q�
+ +
�F o� RENTON
NT
Planning/Building/Public Works Dept.
RENTON SONIC
DETAILS
DATE:
02/19/19
V /
z
O
7�
DESIGNED:
NB
FIELDBOOK:
PAGE:
;/21 /17
NB
DRAWN: TKB
ONE INCH
DRAWING N0:
/28/16
NB
CHECKED:
NB
Al FULL SCALE
IF NOT ONE INCHLU
SCALE ACCORDINGLY
APPR
APPROVED :NB
SHEET: OF: 16