HomeMy WebLinkAboutR-392917N 0') co CD W U) U_ Z O (/) Z O P- Z W * * SURFACE MOUNTING PANEL SCHEDULE 65,000 AIC No. MDP LOCATION: EXTERIOR SERVING: SONICS 120/208 VOLTS 3PHASE 4WIRE 600 AMPS WITH 600 MAIN BREAKER COT N0. LOAD DESCRIPTION KVA TRIP TRIP AMPS AMPS KVA LOAD DESCRIPTION COT N0. 1 PANEL A 16.80 225 3 7a57 3 2Z5Z 7 3 125 3 100 3 200 3 100 3 30/ i2 3QL 2 3QZ 2 15L 2 29Z 2 2QL 2 39Z 2 125 3 20 20 3QZ 2 SPARE 2 3 4 5 PANEL B SPARE 6 8 7 4.50 9 SPARE 10 11 12 13 PANEL C .50 SPARE 14 16 15 17 SPARE 18 19 SPARE 20 21 23 SPARE 22 24 25 SPARE SPARE 26 27 28 29 31 SPARE SPARE 30 32 33 34 35 SPARE 36 37 39 SPARE SPARE SPARE 38 40 41 42 REMARKS: SERVICE ENTRANCE RATED. CONNECTED LOAD: 28.3 KVA 79 AMPS DEMAND LOAD: 30.2 KVA 84 AMPS * PROVIDE HACR BREAKER ** PROVIDE GFCI BREAKER PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. PANEL MDP LOAD CALCULATIONS SERVICE KVA LOAD FACTOR NEC REF. DEMAND LOAD LIGHTING 7.76 X 1.25 220.19(A)(1) = 9.70 RECEPTS TO 10KW - X 1.00 220.44 = - RECEPTS OVER 10KW X 0.50 220.44 = - MOTORS (LARGEST) X 1.25 430.24 = - MOTORS X 1.00 430.24 = - KITCHEN EQUIP. X 0.65 220.56 = - WELDERS - X 1.00 630.11(B) _ - AIR CONDITIONING X 1.00 220.50 = - ELECTRIC HEAT - X 1.00 220.51 = - MISCELLANEOUS 20.54 X 1.00 = 20.54 TOTAL CONNECTED 28.3 KVA (79 AMPS) METER 120/208V, 3P/600 AMP ELECTRICAL SERVICE FROM POWER COMPANY TRANSFORMER EC TO PROVIDE FULL COORDINATION WITH U TI LI TY. C.T. CABINET O BY UTILITY CO. 2 SETS - (4) 350 KCMIL THWN, 4" CONDUITS TOTAL DEMAND 30.2 KVA (84 AMPS) 25,150A MDP 120/208V, 3 PHASE, 65 KAIC, 42 SPACE DISTRIBUTION PANEL "MDP" WITH 600 A MAIN CIRCUIT BREAKER NEMA 3R 2 SETS - (4) 350 KCMIL THWN, # 2/0 CU GROUND = 4" CONDUITS FLUSH MOUNTING PANEL SCHEDULE 22,000 AIC No. A LOCATION: KITCHEN SERVING: SONICS 120/208 VOLTS 3PHASE 4WIRE 225 AMPS WITH MAIN LUGS COT N0. LOAD DESCRIPTION KVA TRIP TRIP AMPS AMPS KVA LOAD DESCRIPTION COT N0. 1 CANOPY LIGHTING 1.28 20 20 30 30 20 11 20 30 2 20 J 20 J 20 l 20 .80 CANOPY PAYS 2 3 SPARE .80 CANOPY MENU 4 5 CANOPY NIGHT LIGHTING CANOPY STAR STALL LED .23 SPARE SIGNAGE 6 8 7 .60 1.00 9 CANOPY STAR STALL LED .10 1.00 SIGNAGE 10 11 SPARE SPARE 12 13 SPARE 14 16 15 CANOPY & TOWER LED 1.00 17 TOWER SIGN 1.20 18 19 TOWER SIGN 1.20 20 21 TOWER SIGN 1.20 22 24 23 TOWER SIGN 1.20 25 TOWER LIGHTING .65 26 27 SPARE 28 29 SPARE SPARE 30 32 31 33 READER BOARD SIGN 3.84 34 35 36 37 POLE SIGN ORDER PEDESTAL 1.20 38 40 39 1.00 41 MENU BOARD 1.00 42 43 PREVIEW BOARD 1.00 44 45 ORDER PEDESTAL 1.00 46 48 47 MENU BOARD 1.00 49 PREVIEW BOARD 1.00 50 51 SPARE 52 53 1 SPARE SPARE 54 REMARKS:. CONNECTED LOAD: 16.8 KVA 47 AMPS DEMAND LOAD: 17.1 KVA 48 AMPS * PROVIDE GFI BREAKER PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. PANEL A LOAD CALCULATIONS SERVICE KVA LOAD FACTOR NEC REF. DEMAND LOAD LIGHTING 3.26 X 1.25 220.19(A)(1) = 4.08 RECEPTS TO 10KW - X 1.00 220.44 = - RECEPTS OVER 10KW - X 0.50 220.44 = - MOTORS (LARGEST) X 1.25 430.24 = MOTORS - X 1.00 430.24 = - KITCHEN EQUIP. X 1.00 220.56 = WELDERS - X 1.00 630.11(B) _ - AIR CONDITIONING X 1.00 220.50 = ELECTRIC HEAT - X 1.00 220.51 = - MISCELLANEOUS 20.04 X 1.00 = 20.04 TOTAL CONNECTED 16.8 KVA (47 AMPS) PROVIDE 65K/22K SERIES RATINGS FROM BREAKERS IN MDP FEEDING PANELS A, B, & C. EXTERIOR I INTERIOR 21,796A PANEL "A" 120/208V. 3PH., 4W. ISOLATED GRID. 225A. M.L.O. FLUSH MTD. NEMA 1 (4) # 1 /0 CU THWN (1) # 6 CU GROUND (1) # 6 CU IG GROUND (1) 2" CONDUIT SEE GROUNDING DETAIL THIS SHEET 600A ELECTRICAL RISER DIAGRAM SCALE: N.T.S. 20,955A PANEL "B" 120/208V 3PH., 4W. 225A. M.L.O. FLUSH MTD. NEMA 1 SECTION 1 (4) # 1 /0 CU TH WN (1) # 6 CU GROUND (1) 2" CONDUIT TOTAL DEMAND 17.1 KVA (48 AMPS) 19,340A PANEL "C" 120/208V 3PH., 4W. 225A. M.L.O. FLUSH MTD. NEMA 1 NO. REVISION J LIGHTING CONTACTORS. SEE DETAIL ON E2.01 FOR ADDITIONAL INFORMATION. FLUSH MOUNTING PANEL SCHEDULE 22,000 AIC No. B LOCATION: KITCHEN SERVING: SONICS 120/208 VOLTS 3PHASE 4WIRE 225 AMPS WITH MAIN LUGS COT N0. LOAD DESCRIPTION KVA TRIP TRIP AMPS AMPS KVA LOAD DESCRIPTION COT N0. 1 SPARE ��3 30 3 20 20 20 30 2 20 30 3 30 2 �It !30 73 20 30 2 20 20 60 3 - 20 20 2QZ 2 20 2 60 3 - SPARE 2 3 4 5 SPARE SPARE 6 8 7 9 10 11 12 13 SPARE if SPARE 14 15 16 17 18 19 SPARE 20 21 22 23 SPARE SPARE 24 25 SPARE SPARE 26 27 1.50 POLE MOUNTED LIGHTS 28 29 30 31 SPARE 3.00 POLE MOUNTED LIGHTS 32 33 34 35 SPARE SPARE 36 37 38 39 40 41 SPARE - 42 REMARKS: CONNECTED LOAD: 4.5 KVA 13 AMPS DEMAND LOAD: 5.6 KVA 16 AMPS * SHUNT TRIP BREAKER PROVIDE HANDLE TIES FOR ALL MULTI CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. ELECTRICAL CONTRACTOR MUST PROVIDE EQUIPMENT CAPABLE OF A SERIES FAULT CURRENT RATING OF NOT LESS THAN 65K AIC. PROVIDE EQUIPMENT MANUFACTURERS SUBMITTAL DATA SHOWING COMBINED RATING OF FEEDER CIRCUIT BREAKER AT MDP AND DOWN STREAM BREAKERS AT PANELS "A", "B" & „C„ (4) # 1 CU THWN (1) # 6 CU GROUND (1) 1-1/2" CONDUIT * FLUSH MOUNTING PANEL SCHEDULE 22,000 AIC No. C LOCATION: KITCHEN SERVING: SONICS 120/208 VOLTS 3PHASE 4WIRE 225 AMPS WITH MAIN LUGS COT N0. LOAD DESCRIPTION KVA TRIP TRIP AMPS AMPS KVA LOAD DESCRIPTION COT N0. 1 SPARE 20 2 20 20 20 �2Z 15 2 20 �'2/ 20 2 20 20 20 l l 20 20 2 20 20 SPARE 2 3 4 5 6 8 7 9 10 11 12 13 15 14 16 17 18 19 20 21 23 22 24 25 26 27 28 29 30 32 31 33 34 35 36 37 SPARE .50 38 40 39 BACKFLOW DEVICE 41 SPARE SPARE 42 REMARKS: L CONNECTED LOAD: .5 KVA 1 AMPS DEMAND LOAD: .5 KVA 1 AMPS PROVIDE HANDLE TIES FOR ALL MULTI -CIRCUIT HOMERUNS SHARING A NEUTRAL PER THE NATIONAL ELECTRIC CODE ARTICLE 210.4 MULTIWIRE BRANCH CIRCUITS, PART (B) DISCONNECTING MEANS. DRAWINGS ARE DIAGRAMMATIC. WHERE THE CONTRACTOR MODIFIES THE CIRCUITING, THE CONTRACTOR SHALL PROVIDE AN INDIVIDUAL NEUTRAL PER CIRCUIT, MULTI -POLE CIRCUIT BREAKERS, OR CIRCUIT BREAKER HANDLE TIE TO MEET THE NEC ARTICLE. ALL COSTS ASSOCIATED WITH MODIFICATIONS SHALL BE INCLUDED IN THE CONTRACTOR'S BID. PANEL B LOAD CALCULATIONS PANEL C LOAD CALCULATIONS SERVICE KVA LOAD FACTOR NEC REF. DEMAND LOAD SERVICE KVA LOAD FACTOR NEC REF. DEMAND LOAD LIGHTING 4.50 X 1.25 220.19(A)(1) = 5.63 LIGHTING - X 1.25 220.19(A)(1) _ RECEPTS TO 10KW - X 1.00 220.44 = - RECEPTS TO 10KW - X 1.00 220.44 = - RECEPTS OVER 10KW - X 0.50 220.44 = RECEPTS OVER 10KW - X 0.50 220.44 = MOTORS (LARGEST) - X 1.25 430.24 = MOTORS (LARGEST) - X 1.25 430.24 = MOTORS - X 1.00 430.24 = MOTORS - X 1.00 430.24 = KITCHEN EQUIP. - X 0.65 220.56 = KITCHEN EQUIP. - X 0.65 220.56 = WELDERS - X 1.00 630.11(B) _ - WELDERS - X 1.00 630.11(B) _ - AIR CONDITIONING - X 1.00 220.50 = AIR CONDITIONING - X 1.00 220.50 = ELECTRIC HEAT - X 1.00 220.51 = - ELECTRIC HEAT - X 1.00 220.51 = - MISCELLANEOUS - X 1.00 = MISCELLANEOUS .50 X 1.00 = .50 TOTAL CONNECTED 4.5 KVA (13 AMPS) METAL FRAME OF BUILDING CONNECTIONS MADE WITHIN 5'-0" OF POINT OF ENTRANCE OF PIPE #2/0 AWG CU * size per table 250.66, 3/0 max #6 AWG CU MIN. 0" x 10'-0" COPPE CLAD GROUND ROD TOTAL DEMAND 5.6 KVA (16 AMPS) Ou0 D TOTAL CONNECTED .5 KVA (1 AMPS) MAIN SERVICE EQUIPMENT #2/0 AWG CU GROUNDING ELECTRODE CONDUCTOR * size per table 250.66, 3/0 max AL WATER PIPE / CONCRETE ENCASED ELECTRODE �- AT LEAST 20'-0" LONG (#4 AWG AWG CU. CU MIN. OR D" DIA. MIN. STEEL REINFORCING BAR) 0 SIZED NO SMALLER THAN #2 AWG CU MIN. GROUND RING AT THE GROUND RING LEAST 20'-0" LONG i3� GROUNDING ELECTRODE DETAIL SCALE: N.T.S. TOTAL DEMAND .5 KVA (1 AMPS) R-3929017. APPROVED FOR CONSTRUCTION SUBJECT TO ERRORS AND OMISSIONS O N N O O O T a J BY: DATE: BY: DATE: CROSS ENGINEERS, INC BY: DATE: 6509 6th Avenue Phone: (253) 759-0118 BY: DATE: _U Z Tacoma, WA 98406 Job Number: 17-046 O info@crossengineers.com 0 SURVI YI D_ SCALE: AS SHOWN VERTICAL: DAVD 1988 HORIZONTAL NAD 1983/1991 C T Y O RENTON SONICS DATE: 4.28.2017 Z DI SlGfdl li B.JA FIELDBOOK: R E N TO N PACE Z DRA,CK BJA POWER RISER DIAGRAM / DRAWING N0: EO.0 1 ON= INC- U AI FI SGAIF IF VOT ONE NCH °ABM Planning/Building/Public works Dept. PANEL SCHEDULES Z W CH ARID _jv DA E APPR SCALE ACCORDINGY Ir APPROVI D. SHEET. OF 15 16