R-392918
GENERAL NOTES N co W U_ z O U) z O z w rr SIGN ELECTRICAL SITE PLAN SCALE: 1 "=10'-0" SURVEYED: 5CAI1: DESIGNED: AS SHOWN JA DRAWN: BJA ONE INCH CHECKED: AT FULL SCALE IF NOT ONE INCH APPROVED: SCALE ACCORDINGLY N0. REVISION EU DATE APPR VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM 1. THIS PLAN IS FOR WIRING AND SCHEMATIC PURPOSES. DO NOT SCALE THIS PLAN. REFER TO CIVIL SITE PLAN. 2. ALL LOW VOLTAGE WIRING INCLUDING WIRING FOR MUSIC, PAYS AND SPEAKERS SHALL BE RATED FOR 600 VOLTS MINIMUM IF IN A CONDUIT WITH 120V WIRING. 3. E.C. TO PROVIDE HANDLE TIES TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS OF MULTI -WIRE BRANCH CIRCUITS PER NEC 210.4. KEYED NOTES Ot LOW VOLTAGE TRANSFORMER FOR LED STALL STARS. TRANSFORMER TO BE ROOF MOUNTED IN WP ENCLOSURE. ELECTRICAL CONTRACTOR SHALL COORDINATE REQUIREMENT WITH LED INSTALLER. CONNECT A MAXIMUM OF (8) STALL STARS PER TRANSFORMER. SEE SHEET A7.01 FOR EXACT NUMBER OF "STALL STARS" & SHEET SP5.01 FOR TRANSFORMER SPECIFICATION. O2 SEE ARCHITECTURAL SHEET A7.01 FOR MORE INFORMATION ON STALL STARS. VERIFY QUANTITY WITH DETAIL. O PROVIDE JUNCTION BOXES W/WP COVER ABOVE CANOPY, MTD. TO ROOF FOR CONNECTION / EXTENTION OF CONDUIT & WIRING FROM CANOPY LIGHTS, MENU LIGHTS, & LED LIGHTING TRANSFORMERS. EXTEND CONDUIT FROM JUNCTION BOX TO ADJ. SUPPORT COLUMN & DOWN COLUMN. EXTEND CONDUIT & CONDUCTORS TO PANEL "A". O LOLLYPOP STATIONS - PROVIDE JUNCTION BOXES W/WP COVER MOUNTED ON BACKSIDE OF MENU STRUCTURE FOR MENU LIGHTS. EXTEND CONDUIT FROM JUNCTION BOX TO ADJ. MENU FOR CONTUATION. EXTEND CONDUIT & CONDUCTORS TO PANEL "A". O MOUNT CANOPY LIGHTING FIXTURES TO CANOPY DECK, ALIGN WITH TOP OF CANOPY COLUMNS. Os CANOPY LIGHTING CIRCUITRY SHALL BE ROUTED OVERHEAD. 0 1-1/2" CONDUIT LOOPED OVERHEAD FOR MENU SPEAKER WIRING. O 1" CONDUIT LOOPED OVERHEAD FOR MENU LIGHTING. Os NIGHT LIGHT. CONNECT TO CIRCUIT A5, BYPASS LIGHTING CONTACTOR. to CONDUIT U.G. TO JUNCTION BOX FOR SPEAKER WIRE AND MUSIC WIRING. - SEE DETAIL 2/E2.03 tt PHOTO CELL ON ROOF FOR LIGHTING CONTROL. 9NOT USED. t3 PROVIDE 250V, 30A/2P, NEMA 3R, NON -FUSED DISCONNECT AT BASE OF MAIN SIGN FOR OPTEC SIGNAGE. CONTRACTOR MUST VERIFY LOCATION ON SITE PLAN. EXTEND 1" CONDUIT W/(4) #10 CU THWN AND (1) #10 THWN CU GROUND FROM PANEL A. IF LENGTH EXCEEDS 150', BRANCH CIRCUITRY SHALL BE UP -SIZED TO (4) #8 CU, (1) #8 CU GROUND IN 1" CONDUIT. 9PROVIDE WP, NEMA 3R, JUNCTION BOX ON ROOF AT BASE OF TOWER FOR EACH TOWER SIGN. E.C. TO PROVIDE CONDUIT, WIRING, AND ELECTRICAL CONNECTION. PROVIDE 120V, 1P/20 AMP SWITCH IN ACCESSIBLE LOCATION FOR SIGN DISCONNECT MEANS. t5 POLE MOUNTED SITE LIGHTING. CONTRACTOR MUST VERIFY NUMBER AND LOCATIONS ON SITE PLAN. EXTEND 1" CONDUIT W/(3) #8 CU THWN & (1) #10 CU GROUND FROM EACH POLE LOCATION TO PANEL "B". MAX. OF 2 HEADS PER CIRCUIT. SEE CIVIL PLANS FOR SITE DETAILS. is U.G. DETECTOR LOOP, SPEAKER PEDESTAL, & MENU BOARD. SEE CIVIL AND ARCHITECTURAL DRAWINGS FOR SITE DETAILS. 0 1-1/2" CONDUIT UNDERGROUND FOR MENU SPEAKER WIRING. is 3/4" CONDUIT UNDERGROUND FOR PREVIEW BOARD, ORDER PEDESTAL, MENU, & MENU LIGHTING. is NOT USED. Q PROVIDE LED LIGHT OUTLINE AT FRONT EDGE OF ARCHED CANOPY -COLOR "GREEN". PROVIDE LOCATION FOR TRANSFORMER ABOVE SIDE CANOPY AT ONE SIDE IN WATER TIGHT BOX W/ELEC. E.C. TO PROVIDE PIGTAIL COORDINATE REQUIREMENTS WITH LED VENDOR. 2t NOT USED. © TRANSFORMER AND WHIP FOR TOWER LED -COLOR "BLUE"- SUPPLIED WITH TOWER. E.C. TO PROVIDE CONDUIT, WIRING, AND ELEC. CONNECTION. © PROVIDE (1) 5/8" X 8' GALVANIZED GROUND ROD AT BASE OF MAIN SIGN. INSTALL (1) #6 CU GROUND WIRE IN CONDUIT UP THE POLE TO A HEIGHT OF 12' ABOVE GRADE. LEAVE 15' EXCESS OF THE GROUND WIRE FOR BONDING TO INCOMING GROUND WIRE. CONNECTION BY OTHERS. 0 TYPE "P" WALL MOUNTED FLOOD LIGHTS TO ILLUMINATE UNDERSIDE OF TOWER. MOUNT LIGHT TO WALLS OF TOWER. 0 AUTOMATIC LAWN SPRINKLER CONTROLLER. MOUNTED AT 60" A.F.F.. INSTALL 1-1/2" CONDUIT U.G. TO NEAREST LANDSCAPE AREA. WIRING BY OTHERS. REF: LANDSCAPE PLAN, IF PROVIDED. VERIFY EXACT LOCATION. 0 120V, 1PH, 20 AMP GFI RECEIPT. FOR AUTOMATIC SPRINKLER CONTROLLER AND HEAT TAPE FOR HOT AND COLD WATER LINES. REFER TO SHEET E2.02 FOR LOCATION & CIRCUIT INFORMATION. 0 PROVIDE DISCONNECT SWITCH, POWER, & LOW VOLTAGE CONDUIT FOR POLE MOUNTED SIGN. VERIFY SIZE OF CONDUIT AND ALL SIGN REQUIREMENTS PRIOR TO BID AND INCLUDE IN BID. ADJUST ACCORDINGLY. <@ PROVIDE POWER & ALL ASSOCIATED COMPONENTS FOR BACKFLOW DEVICE WIRING CONNECTION. VERIFY LOCATION AND ALL REQUIREMENTS PRIOR TO BID AND INCLUDE IN BID. ADJUST ACCORDINGLY. 0 PROVIDE 2" CONDUIT U.G. TO JUNCTION BOX WITH PULL STRING FOR FUTURE POS TO COLUMN AS SHOWN. 3o PROVIDE 3/4" CONDUIT U.G. TO JUNCTION BOX WITH PULL STRING FOR FUTURE POWER TO COLUMN AS SHOWN. 3t NOT USED. 0 PROVIDE 3/4" CONDUIT U.G. TO JUNCTION BOX FOR EVERY 15 STALLS. Q PROVIDE 2" CONDUIT U.G. FOR EVERY 8 STALLS WITH PULL STRING FOR PAYS, MUSIC, & SPEAKER WIRING. 1-1/2" CONDUIT LOOPED UNDERGROUND FOR MENU SPEAKER WIRING AND 1" CONDUIT LOOPED UNDERGROUND FOR MENU LIGHTING. CROSS ENGINEERS, INC 6509 6th Avenue Tacoma, WA 98406 info@crossengineers.com Phone: (253) 759-0118 Job Number: 17-046 C TY OF REN ON Planning/Building/Public Works Dept. R-3929018 APPROVED FOR CONSTRUCTION SUBJECT TO ERRORS AND OMISSIONS BY: DATE: BY: DATE: BY: DATE: _U BY: DATE: z �0 DATE: RENTON SONICS 4.28.2017 z FIELDBOOK: O ELECTRICAL SITE PLAN PAGE z DRAWING NO E1.01 w SHEET C IF: 1 C