CS_WATERSHED - FIREALARM - SUBMITTALS_20221222_V1
11409 58Th Ave E- Puyallup, WA. 98373 FIRE ALARM SUBMITTALS Watershed 625 Williams AVE S Renton WA, 98057 GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2016 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0637 Rev. R page 1 of 2 E3 Series® Control Panel Approved City of Denver7165-1703:0125 3025415 APPROVED FM Reference Certificate of ComplianceVMA-45894-02C(Revision 1) FDNY #: 6175COA # 231-06-E MEAApproved SIGNALING S1869 12Class High Rise Class City of ChicagoApproved Description The E3 Series® Expandable Emergency Evacuation Sys- tem by Gamewell-FCI is in the forefront of the latest gener- ation of fire alarm control panels. Employing the new high- speed Velociti® sensors, the E3 Series provides previously unattainable polling speed and response together with the flexibility demanded by today’s emergency evacuation sys- tems. In addition to their high-speed polling rate, the Veloc- iti Series of sensors feature bi-polar LEDs that flash green for normal polling, and light red steadily to indicate an alarm. The E3 Series is equipped with an 80-character LCD-E3 alphanumeric LCD display that allows 40 characters to be user-defined for custom installations. Up to six keyboard LCD displays may also be remotely located. In addition, you can install five of the familiar LCD-7100/RAN-7100 remote displays. The displays show instant system status information and can be connected in any desired area of an installation. A high-speed 32-bit processor easily tackles a wide array of applications from small office buildings to multi-complex, high-rise installations. The 64 node networking is made possible by 625K baud/ ARCNET communications using twisted-pair copper cable, fiber-optic cable, or a combination of both. In addition, the Addressable Node Expander (ANX) board expands the network to 122 nodes. The basic E3 Series is equipped with an ILI-MB-E3/ILI95- MB-E3 Intelligent Loop Interface-Main Board, ILI-S-E3/ ILI95-S-E3 Intelligent Loop Interface Expansion Board, ANX, and ASM-16 Addressable Switch Module that fea- tures 16 software programmable switches, each accompa- nied by red, green and yellow LEDs that can be programmed to indicate operation of the switches. Addi- tional ASM-16 modules may be added to expand the oper- ation to a plateau previously unimagined. The Intelligent Loop Interface - Expansion Board (ILI-S-E3/ ILI95-S-E3 provides the E3 Series control panel with two additional electrically isolated signaling line circuits. The layout is similar to the ILI-MB-E3/ILI95-MB-E3 with the exception that a number of components are omitted. It occupies one node on the Broadband network. E3 Series® and Velociti® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Features • IBC Seismic Certified. • Listed under UL® Standard 864, 9th Edition. • UL Listed for smoke control (dedicated and non-dedi- cated) when properly configured. • UL Listed and FM Approved for Pre-action/Deluge and Agent Releasing. • Styles 4, 6, or 7* signaling line circuits. • Two to 244 SLCs each supporting 159 sensors, 159 modules and 159 addressable sounder bases. • 625K baud ARCNET communications using wire, fiber, or mixed configurations for installation flexibility. • High-speed 32 bit processor and 8100 event history log. • Advanced Boolean logic-based programming such as AND, OR, NOT, time delay and calendar functions configurable via computer programming. • Supports up to (16), ASM-16 addressable switch or ANU-48 LED driver modules per ILI-MB-E3/ILI95-MB-E3. • Two Class A, Style Z or Class B, Style Y, notification appliance circuits rated at 2.0 amps. per circuit. • Integral city connection. • Flexible 115,200 baud high speed RS-232 interface. • 40 character user-defined text per device. • 15 LCD-SLP displays/annunciators, 6 LCD-E3 displays/ annunciators, 5 LCD-7100/RAN-7100 remote LED annunciators per ILI-MB-E3/ILI95-MB-E3. *Style 7 wiring requires the use of System Sensor M500X Isolator Modules. Expandable Emergency Evacuation System E3 Series GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-71189020-0637 Rev. R page 2 of 2 www.gamewell-fci.com Description (Continued) Each ILI-MB-E3/ILI95-MB-E3 can support as many as six- teen ANU-48 LED Driver modules supporting hundreds of LEDs on a 3rd party graphic annunciator for remote annun- ciation. The ANU-48 modules may be installed in any Listed remote annunciator. It can be remotely located via an RS-485 serial interface. An array of cabinets allows for neat, compact, attractive installations. Installation The E3 Series expandable emergency evacuation system offers four cabinet size options. A typical cabinet includes a backbox, an inner door, and an outer door. The E3 Series cabinet assembly is a compact 19 3/8” (49 cm) wide. wall- mounted enclosure. Cabinet A includes the following four options: • Cabinet A1 inner door mounted to the backbox. The backbox houses one NGA module. • Cabinet A2 inner door mounted to the backbox. The backbox houses one LCD-E3 module. • Two or three-bay inner door mounted to the backbox. The backbox typically houses one LCD-E3, or one NGA, and one or two ASM-16 modules. Cabinet B contains a space for the ILI-MB-E3/ILI95-MB-E3, PM-9/PM-9G modules and batteries set inside the back- box. Additional module options mounted on the backbox include the DACT-E3, and RPT-E3 or ILI-S-E3/ILI95-S-E3/ ANX. The 2-bay inner door houses one LCD-E3 module and one ASM-16 module. Both Cabinets C and D include the following: • Pre-assembled outer door that gives visibility to the fire fighter’s phone handset and a microphone voice messaging system. • Two inner door panel selections that may contain optional modules to meet the facility operation requirements. In the Cabinet B, C and D backboxes, the ANX appears in the same place as the ILI-MB-E3/ILI95-MB-E3 and PM-9/ PM-9G. For information on the installation instructions for any of the E3 Series cabinets, refer to the E3 Series® Expandable Emergency Evacuation Manual Part Number: LS10080-051GF-E. Features (Continued) Velociti® Intelligent Sensor Features: • Poll 318 devices in less than two seconds. • Activate up to 159 outputs in less than five seconds. • LED’s blink associated device address during Walk Test. • Fully digital, hi-precision protocol. • Up to 9 levels of sensitivity adjustment. • Pre-Alarm adjustable between 15 levels for both Alert and Action. • Day/night automatic sensing adjustment. • Sensitivity windows: - Ion .05 to 2% obscuration. - Photo 1 to 3% obscuration. - Laser .02 to 2% obscuration. - MCS Acclimate2F .5 to 4%, also self-adjustable options 1 to 2%, 2 to 3%, and 3 to 4%. - HARSH 1 to 3% obscuration. • Drift compensation. • Each Loop Card has its own integral processor providing maximum survivability on loss of any other component. SLC provides full response on loss of any other system processor. • Optional programmable switches can be configured to enable, disable or group any combination of output devices. • Integrated point or Grouped Cross Zoning allows for numerous devices installed at any location to cooperate and determine alarm condition. • Automatic detector sensitivity testing. • DIRTY and VERY DIRTY detector maintenance alerts. Specifications Operating Voltage:24 VDC Operating Temperature: Not to exceed the range of 32° to 120° F (0 to 49° C) Relative Humidity:Not to exceed 93% non-con- densing at 90° F (32° C) Ordering Information Part Number Description ILI-MB-E3 Intelligent Loop Interface-Main Board ILI95-MB-E3 Intelligent Loop Interface-Main Board ILI-S-E3 Intelligent Loop Interface-Expansion Board ILI95-S-E3 Intelligent Loop Interface-Expansion Board ANX-SR Addressable Node Expander-Single Ring ANX-MR-FO Addressable Node Expander-Multi-Ring Fiber Optic ANX-MR-UTP Addressable Node Expander-Multi-Ring Twisted-pair LCD-E3 LCD-E3, LCD Keypad Display RPT-E3-UTP Network Repeater, unshielded, twisted-pair FML-E3 Multi-Mode Fiber-Optic Module FSL-E3 Single-Mode Fiber-Optic Module DACT-E3 Digital Alarm Communicator Transmitter ANU-48 ANU-48 LED Driver Module ASM-16 Addressable Switch Module NGA LCD Network Graphic Annunciator PM-9 Power Supply Module PM-9G Power Supply Module LCD-7100 Remote LCD Display RAN-7100 Remote LCD Display For additional information on the cabinets, refer to the E3 Series Cabinets data sheet (Part Number: 9020-0649). Seismic Battery Bracket Kits For information on the types of Seismic Battery Bracket Kits that are available, the Seismic Battery Bracket Kit Part Numbers and the installation instructions, refer to the following documents: • Seismic Battery Bracket Installation Guide, P/N: 53839 • E3 Series Cabinets Data Sheet, P/N: 9020-0649 LCD-SLP LCD Touchscreen Annunciator Display GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2016 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60782 Rev. E page 1 of 1 FDNY: COA-#6162 MEA S1869 SIGNALING 7165-1703:0176 City ofChicago Approved Class 1Reference Certificate of Compliance VMA-45894-02C APPROVED FM Description The Gamewell-FCI, Liquid Crystal Display, Smart LoopPanel (LCD-SLP) is a touchscreen annunciator displayused with the S3 Series and E3 Series® Systems. TheLCD-SLP provides an easy-to-use, intuitive interface forthe operator’s control. The 4.3” (10.92 cm) color touchscreendisplay shows the following:• System Status • Service modes• Event details The following identify the LED Indicators that display on the panel. • AC (green) • Supervisory (yellow) • Fire Alarm (red) • Trouble (yellow) • Hazard (blue) • Silenced (yellow) The five fully-programmable front panel switch/LED combi-nations provide a direct access to perform the followingtasks: • Device Bypass • Lamp Test• Enable/Disable Groups or Devices The display features the following physical switches. •Menu •System Reset • Five Programmable Switches •Drift Walk Test Installation The LCD-SLP is adaptable for installation in the S3, E3® Series or Retrofit cabinets. For additional information, referto the E3 Series Cabinets Data Sheet, P/N:9020-0649 • S3 Series Cabinets - SLP-BB basic system enclosure - S3BB-BB/S3BB-RB system enclosure • E3 Series ® Cabinets - AA size cabinet (E3BB-BAA, E3BB-RAA) - A2 size cabinet (E3BB-BA2, E3BB-RA2)- A size flush cabinet (E3BB-FLUSH-LCD)- B-Slim cabinet (E3BB-RBSLIM)- B size cabinet (E3BB-BB, E3BB-RB) - C size cabinet (E3BB-BC/INCC, E3BB-RC/INCC) - D size cabinet (E3BB-BD/INCC, E3BB-RD/INCC) • Retrofit Cabinets - IF600-RETROFIT - 7200-B-RETROFIT - 7200-C-RETROFIT Specifications Operating Voltage:24 VDC FWR Operating Current:0.030 amp Alarm Current:0.065 amp Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity:0 to 93%,non-condensing at 90° F (32° C) E3 Series® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. Features LCD-SLP • Listed per ANSI/UL ® Standard 864 9th Edition. • UL Listed and FM approved for Pre-Action/Deluge and Agent Releasing. • Provides 4.3” (10.92 cm) color touchscreen display of System Events. • Includes five custom function buttons with LEDs for direct access to system controls. • Offers the following installation options: - Locally mounted in the S3 Series panels. - Remotely mounted in the E3 Series, A2 cabinet or LCD Flush enclosure. • Displays the following six LED indicators: - Alarm - Hazard - Trouble - NAC Silence - Supervisory - AC Power • Shows the Hazard LED to indicate gas, carbon monoxide or other toxic gases. • Both the E3 Series (ILI-MB-E3/ILI95-MB-E3) and the S3 Series (SLP) support up to 15 LCD-SLP displays via the RS-485 serial interface. Ordering Information Part Number Description LCD-SLP LCD Touchscreen display unit E3BB-BA2 Remote enclosure with inner door, black, one LCD slot E3BB-RA2 Remote enclosure with inner door, red, one LCD slot E3BB-FLUSH-LCD Remote flush mounting enclosure, black, LCD slot GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2015 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0555 Rev. P page 1 of 1 PM-9 PM-9 Power Supply S1869 Vol. 14 S1949 Vol. 19 APPROVED FM 3017416 7165-1703:0125 Approved City of DENVERApproved Class 1 Class 2 High Rise Chicago City ofSIGNALING FDNY: COA #6077 MEAApproved Description •The Gamewell-FCI, PM-9 Power Supply is a switching power supply that provides 9 amperes of filtered and regu- lated 24 VDC (nominal). It provides the power to the INX Transponder assembly and all of the E3 Series compo- nents. It is a component of the following systems. • E3 Series® Expandable Emergency Evacuation System • E3 Series Combined Fire and Mass Notification System • E3 Series Broadband Voice Evacuation System • NetSOLO ® System •The PM-9 has an internal battery charging circuit capable of maintaining up to 55 A/H batteries. This module is designed for use with the Gamewell-FCI distributed audio networks. •Installation Typically, the PM-9 Module can be mounted in the follow- ing E3 Series cabinets: • Cabinet B and D, backbox • Cabinet C, INX-E3 sub-assembly plate • Cabinet C, INCC-E3 sub-assembly plate • Cabinet D, E3-INX-D Plate • Cabinet D, E3-ILI-D Plate •For information on the installation of the PM-9, refer to the following documents: • E3 Series Expandable Emergency Evacuation Manual, P/N: LS10080-000GF-E • PM-9 Installation Instructions, P/N: 9000-0548 • Mass Notification System Manual, P/N:LS10013-000GF-E •Specifications •Input Voltage:120 VAC 60 Hz @ 3.5 A. max. Output Voltage:24 VDC (nominal) FWR Output Current:9 amperes Output Current:1 ampere battery charging current Alarm Current:0.050 amp Operating Temperature:32° to 120° F (0° to 49° C) Relative Humidity:0 to 93% (non-condensing) at 90° F (32° C) Dimensions:10 1/2” W x 5” H x 2” D (27 x 13 x 5 cm) E3 Series® and NetSOLO® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. Features • Listed under UL ® Standard 864, 9th Edition. • Listed under UL Standard UL2572 for Mass Notification. • Includes 9 ampere, filtered, regulated power supply. • Provides 1 ampere battery charging current. • Offers energy and space saving switching technology. • Contains an integral battery charger capable of recharging up to 55 AH batteries. (Batteries not furnished). Ordering Information Part Number Description PM-9 Power supply 29229 AC Line Filter Kit PM-9 GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2015 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60901 Rev. A page 1 of 1 PRN-7 Printer Printer S35611 E351188 Description General The PRN-7 printer is used with the Gamewell-FCI fire alarm control panels (FACPs) and provides printer capabil- ity to produce a written record of system events and status changes. In the Gamewell-FCI applications, the PRN-7 can be used with the following systems. •E3 Series® System • S3 Series System • 7100 Series System • 600 Series System Applications Printed transaction records reduce the man-hours required to install and maintain a system. A printed record of all sys- tem events (alarms, troubles, etc.) and status changes can be especially valuable in the event of a disputed incident. Construction and Operation The printer is housed in its own separate enclosure and is suitable for placement on a desktop, counter, or table. Installation Install the PRN-7 printer in a location no further than 20 ft/ 6.10 m (actual cable length) from the fire alarm control panel. The PRN-7 should be placed in a secure area to prevent theft of the printer and/or printed records. For information on the proper method and PIN numbers required to complete the electrical connection to the fire alarm control panel, refer to the Gamewell-FCI module specific documentation located on the Gamewell-FCI Web- site, www.gamewell-fci.com. NOTE: During a primary power failure, if it is necessary to use the printer, Gamewell-FCI recommends that you use a separate UL-Listed Uninterruptible Power Supply (UPS) system. Specifications Printer Method:Serial printing with a 24-pin matrix print head. Printing Speed (copy draft):333 cps at 10 cpi. Character Density:10 cpi standard. (12, 15, 17.1, and 20 cpi available via front panel). Graphic Resolution (VxH):Up to 360 x 360 dpi. Ribbon Life (approx.):6 million characters (DPQ). Acoustic Noise Level:52 dBA (approx.). E3 Series® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories, Inc. Features • Produces a hard copy printout of all system events and status changes. • Registers the time stamps printed on the record of each event and status change including the current time-of-day and date. • Uses standard 9” x 11” tractor-feed fan-fold paper. • Prints 80 columns of data at 10 characters per inch. • Provides printed records of the system configuration and the addressable device parameters. • Includes a 24-pin print head. • Offers accoustic noise levels of approximately 52 dBA. Ordering Information Part Number Description PRN-7 24-pin dot-matrix printer, 110-230 VAC power. PRN-7 Printer GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved.www.gamewell-fci.com 9020-0554 Rev. O page 1 of 1 ASM-16 ASM-16 Addressable Switch Module Rear View Front View APPROVED FM 3017416S1869 SIGNALING Approved City of Chicago Class 1 Class 2High Rise 7165-1703:01257170-1703:0126 FDNY: COA # 231-06-E MEAApproved City of Denver Approved Description •The Gamewell-FCI, ASM-16 Addressable Switch Module serves as the point of interface between an operator and the system’s audio evacuation, fire fighter intercom, and building control circuits. It is a component of the following systems: • E3 Series ® Expandable Emergency Evacuation System •E3 Series Combined Fire and Mass Notification System • E3 Series Broadband Voice Evacuation System•NetSOLO® System •The ASM-16 is a configurable switch input sub-assembly with 16 switches and 48 status LEDs. It may be remotely located via the RS-485 serial interface. Each ASM-16 addressable switch module has 16 push-button switches that can be programmed to serve any function the applica- tion demands. •An ASM-16 switch can be programmed to operate as any of the following functions:• speaker circuit switch • fire fighter phone switch • auxiliary control switch (using a bank of 2 switches (1 switch each for on-off-auto functions). • switches with custom-defined functions: - system reset - system silence - system acknowledge- all-call, phone patch- lamp test, alarm tone on - manual select, etc. •Each ASM-16 switch also has 3 fully programmable LEDs that appear in red, yellow, and green. These LEDs can be programmed to work in concert with their associated push- button switch or they can be programmed to work inde- pendently as status indicators (e.g. on, off, normal, etc.). •An INI-VGC assembly or ILI-MB-E3/ILI95-MB-E3 can accommodate up to 16 ASM-16 modules for a total of 256 switches and 768 LEDs. •Specifications •Operating Voltage:24 VDC (nominal) (from the PM-9/PM-9G power supply) Operating Current:0.011 amp. (with no LEDs lit)Operating Temperature:32° to 120° F (0° to 49° C)Relative Humidity:0 to 93% (non-condensing) at 90° F (32° C) E3 Series® and NetSOLO® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. Features • Listed under UL ® Standard 864, 9th Edition. • Listed under UL ® Standard UL2572 for Mass Notification. • Each INI-VGC supports up to 16 ASM-16 switch modules for a total of 256 switches. • Each ILI-MB-E3/ILI95-MB-E3 supports up to 16 ASM-16 switch modules for a total of 256 switches. • Each ASM-16 switch has 3 fully programmable status, indicating LEDS: red, yellow, and green. • All switch functions are fully software programmable. • Slip-in label inserts allow easily modified switch designations. Ordering Information Part Number Description 1100-0455 Programmable Addressable Switch Module MS-7 Series MS-7 Series Manual Fire Alarm Pull Stations Addressable Devices General The Gamewell-FCI, MS-7 Series manual fire alarm pull stations are available in a wide variety of configurations. The pull stations comply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All pull stations include a key lock/reset which is keyed alike with the Gamewell-FCI fire alarm control panels and other manual fire alarm pull stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a double action pull station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the pull station causes its assigned address to register at the fire alarm control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The station features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated.* The station features screw terminals. The Velociti® Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and focuses on the single device. The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • Conventional stations suitable for use with any UL® Listed control panel • The pull stations (MS- 7LOB) are Listed for outdoor applications • Complies with ADA pull force requirements • Offers surface or semi- flush mounting • Shock and vibration resistant • Both single and double action pull stations available • Includes a tumbler lock for test and reset keyed alike with analog addressable fire alarm controls *Only the red LED is operative in panels that do not operate in Velociti mode 2 MS-7S Single Action Station The MS-7S single action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station, with the additional feature of including both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals used to connect to an initiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell- FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabilities are required. It consists of the following: • An MS-7LR mounted on a plate with an abort switch • LED indicators that signal system normal and system activated status MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model SB-I/O backbox. In retrofit applications, the pull station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior pull stations may be surface mounted or semi-flush mounted on a standard double-gang, or 4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi-flush mounting. NYC-Plate The NYC-Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC-Plate Ordering Information MS-7: Double action station MS-7AF**: Velociti addressable double action station MS-7ASF**: Velociti addressable single action station MS-7S: Single action station, wire leads MS-7SP: Double action station, English and Spanish instructions MS-7LR: Agent release station, dual-action MS-7LRA: Agent release station with abort switch, LED indicators, dual- action MS-7LOB: Double action station, outdoor use (Includes SB-I/O - Indoor/outdoor use backbox) SB-I/O: Indoor/outdoor use backbackbox SB-10: Surface backbox BG12TR: Trim ring for semi-flush mount, plastic NY-PLATE: NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. MS-7 Series Technical Specifications 9020-0616 | F | 11/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Velociti® and Gamewell-FCI are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s MS-7 Series and other products available by visiting www.Gamewell-FCI.com SYSTEMS Material: Lexan® Contact Ratings: 0.25 amps. @ 30 VAC/VDC (resistive) Dimensions: 5 5/8” H x 4 1/4” W x 1 1/4” D (14 x 10.1 x 3.2 cm) Operating Temperature: (MS-7AF, MS-7ASF): 32° to 120° F (0° to 49° C) (MS-7LOB): -30° to 150° F (-35° to 66° C) Relative Humidity : (MS-7AF, MS-7ASF): 10 to 93% (non-condensing) (MS-7LOB): 85% ± 5% @ 86° ± 3.6° (30° ± 2° C) Alarm Current: .0030 amp. 0.007 for LED Supervisory Current: (MS-7AF, MS-7ASF): .00030 amps. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The MS-7 Series is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2465 FM: 3023594 MEA FDNY: 67-02-E Vol. VII CSFM: 7160-1703:0119 7160-1703:0170 7160-1703:0109 ISO 9001 Certification AMM-2F AMM-2F Addressable Monitor Module Addressable Devices General The Gamewell-FCI Velociti® Series, addressable monitor module AMM-2F is a single Style B, Class B initiating device circuit (IDC) with a 47KW end-of-line resistor. This module provides an address for any device or group of devices connected to this circuit on the signaling line circuit (SLC) of the Gamewell-FCI addressable series fire alarm control panel. Any initiating device with normally open (N.O.) dry contacts may be made addressable when connected to the AMM-2F module. The Velociti® Seriems use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The AMM-2F module can be programmed to provide a wide variety of input functions to the Gamewell-FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, plenum detector, waterflow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even possible to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. Ordering Information AMM-2F: Addressable monitor module, single circuit, Style B, Class B FEATURES & BENEFITS •Compact size allows easy installation • Class B, Style B, initiating circuit • 40 Ohm line resistance for each initiating device circuit • Connects to any normally open dry contact device AMM-2F Technical Specifications 9020-0626 | F | 11/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx Velociti® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s AMM-2F and other products available by visiting www.Gamewell-FCI.com System Supervisory Current: .000375 amps Alarm Current: .00060 amps Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 10 to 93% (non-condensing) End-of-Line Resistance: 47K ohms Dimensions: 1.3” L x 2.5” W x 0.5” D (3.3 x 6.4 x 1.3 cm) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The E3 Series Control Panel is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S1949 FM: 3023594 MEA FDNY: 227-03-E VOL. IV CSFM: 7300-1703:0102 ISO 9001 Certification AMM-2IF Velociti® Series AMM-2IF Addressable Dual Monitor Module Addressable Devices General The Gamewell-FCI Velociti® Series, addressable dual monitor module, AMM-2IF, features two Style B, Class B initiating device circuits, each with an end-of-line resistor. This module provides addresses for any device or group of devices connected to each circuit. Any alarm initiating devices with normally open (N.O.) dry contacts, such as heat detectors, 4-wire projected beam smoke detectors, 4-wire smoke detectors, water flow switches, tamper switches, manual stations, etc. may be installed in these circuits. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier designs. The first circuit address is set via a rotary switch. The second circuit is automatically assigned the next higher address. The module has a single panel-controlled red LED. The AMM-2IF module is designed for installation in the signaling line circuit of any Gamewell-FCI addressable control panel. The AMM-2IF is designed to mount in a 4” square junction box, 2 1/8” deep. The initiating device circuit of the AMM-2IF can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. Ordering Information AMM-2IF: Monitor module, two circuit, Style B, Class B FEATURES & BENEFITS • Supports Class B, Style B, initiating device circuits • Provides a visual rotary, decimal switch addressing (01-159) • Offers 40 ohm line resistance for each initiating circuit • Accommodates any normally open contact device • Displays bi-color LEDs flash green whenever the module is addressed, and light steady red on alarm* • Includes a compact size allows easy installation *Note: Only the red LED is operative in panels that do not operate in Velociti® mode. Velociti® Series AMM-2IF Technical Specifications 9020-0629 | F | 11/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx Velociti®, E3 Series® and Gamewell-FCI are registered trademarks of Honeywell International Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s Velociti® Series AMM-2IF and other products available by visiting www.Gamewell-FCI.com SYSTEMS Supervisory Current: 0.0075 amp. Alarm Current: .0057 amp. (LED lit) Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 10 to 93% (non-condensing) Dimensions: 4 1/2” H x 4” mW x 1 1/4” D (11 H x 10.2 W x 3 D cm) (Mounts in a 4” square by 2 1/8” deep box). End-of-line Resistor: 47 K ohms TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The Velociti® Series AMM-2IF is designed to comply with the following standards: UL Standards: UL 864 9th Edition UL 2572 for Mass Notification AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S1949 2572 for Mass Notification FM: 3023594 MEA FDNY: 227-03-E Vol. IV CSFM: 7300-1703:0107 ISO 9001 Certification AOM-2RF Velociti® Series AOM-2RF Addressable Output Relay Control Module Addressable Devices General The Gamewell-FCI Velociti® Series, addressable output relay control module (AOM- 2RF) allows a Gamewell-FCI analog addressable fire alarm control panel to switch discrete relay contacts by code command. The relay provides two isolated sets of Form-C contacts which transfer simultaneously. Circuit connections to the relay contacts are not supervised by the module. The Velociti® Series use a communication protocol that substantially increases the speed of communication between the SLC devices and certain Gamewell-FCI analog addressable fire alarm control panels. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and concentrates on the single device. The net result produces a superior response speed up to five times greater than earlier designs. The AOM-2RF Module is designed for installation in the signaling line circuit of any Gamewell-FCI analog addressable fire alarm control panel. The module contains a panel controlled LED. The AOM-2RF is designed to mount in a 4” (10.16 cm) square junction box 2 1/8” (5.53 cm) deep. Ordering Information AOM-2RF: Addressable output relay control module Table 1 lists the relay contact ratings. FEATURES & BENEFITS • Listed under UL ® Standard 864 • Offers two sets of Form “C” contacts • Provides visual rotary, decimal switch addressing (01-159) •Includes a bi-color LED that flashes green whenever the module is addressed, and lights steady red upon activation* • Designed as a compact size to allow easy installation Note: Only the red LED is operative in panels that do not operate in Velociti® mode CURRENT RATING MAXIMUM VOLTAGE LOAD DESCRIPTION APPLICATION 3A 30 VDC Resistive Non-Coded 2A 30 VDC Resistive Coded 0.9A 110 VDC Resistive Non-Coded 0.5A 125 VAC Resistive Non-Coded 0.5A 30 VDC Inductive (L/R=5ms) Coded 1A 30 VDC Inductive (L/R=2ms) Coded 0.5A 125 VAC Inductive (PF=.35) Non-Coded 0.7A 75 VAC Inductive Non-Coded Table 1: Relay Contact Ratings Velociti® Series AOM-2RF Technical Specifications 9020-0625 | G | 11/17 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx Velociti® Series and Gamewell- FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s Velociti® Series AOM-2RF and other products available by visiting www.Gamewell-FCI.com SYSTEMS Supervisory Current: .000375 amps. Alarm Current: .0065 amps. Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 10 to 93% relative humidity (non- condensing) Dimensions: 4 1/2” H x 4” W x 1 1/4” (11.4 x 10.2 x 3.2 cm) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The Velociti Series® AOM-2RF is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S1913 FM: 3023594 MEA FDNY: 219-02-E Vol. VI CSFM: 7300-1703:0102 ISO 9001 Certification Intrusion Alarm Systems | D126 Standby Battery (12 V, 7 Ah) D126 Standby Battery (12 V, 7 Ah) www.boschsecurity.com u 12 VDC sealed lead-acid u Fully rechargeable u Maintenance‑free u For use as secondary power source u Long service life This battery is a maintenance‑free, sealed lead‑acid, standby and auxiliary power source that provides long service life and dependability. The battery is for use only with charging circuits calibrated for lead‑acid batteries. It is suitable for supplying backup power for fire, security, and access control systems during AC power failures. The D126 fits in any of the currently offered enclosures and connects to the two color‑coded battery leads supplied with the control panel or module. Use a D122 Dual Battery Harness to connect two D126 batteries in parallel and double the amp hour capacity. Certifications and approvals Region Certification USA CSFM California State Fire Marshal (see ourwebsite) Installation/configuration notes Standby power requirementsRefer to the appropriate control panel installation manual for information on calculating the standby battery requirements for the system. Total continuous and intermittent current requirements must not exceed the amp hour capacity of the battery. CompatibilityThe battery is compatible with all Bosch control panels. Parts included Quantity Component 1 12 V battery Technical specifications Capacity Capacity (25 °C) 12 V, 7.2 Ah 20 hour rate Internal resistance Fully charged battery (25 °C)21 MΩ Temperature dependency of capacity (20 hour rate) 40 °C (104 °F) 25 °C (77 °F) 0 °C (32 °F) -15 °C (5 °F) 102% 100% 85% 65% Properties Dimensions 15 cm x 6.5 cm x 9.4 cm (6 in. x 2.5 in. x 3.7 in.) Total height with terminals 10 cm (4 in.) Weight 2.5 kg (5.5 lb) Terminal Faston .187 Ordering information D126 Standby Battery (12 V, 7 Ah) A rechargeable sealed lead‑acid power supply used as a secondary power supply or in auxiliary or ancillary functions. Order number D126 2 | D126 Standby Battery (12 V, 7 Ah) Represented by: Europe, Middle East, Africa:Germany:North America:Asia-Pacific:Bosch Security Systems B.V. P.O. Box 800025600 JB Eindhoven, The NetherlandsPhone: + 31 40 2577 284emea.securitysystems@bosch.com emea.boschsecurity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 585630 GrasbrunnGermanywww.boschsecurity.com Bosch Security Systems, Inc. 130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 9180 onlinehelp@us.bosch.comwww.boschsecurity.us Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21Singapore 573943Phone: +65 6571 2808Fax: +65 6571 2699 apr.securitysystems@bosch.comwww.boschsecurity.asia © Bosch Security Systems 2016 | Data subject to change without notice 2548450571 | en, V11, 28. Nov 2016 ASD-PL2F/ASD-PTL2F ASD-PL2FR Velociti® Series 3 Detectors Photoelectric Detectors Addressable Devices Photoelectric Detector Description The Gamewell-FCI, Velociti® Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI, ASD-PL3 photoelectric detector's re-designed optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment. The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR (DNRW) duct smoke detector housing. The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 135°F fixed temperature thermal sensing. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number after the detector model. Note: Although the E3 Series® and S3 Series panels support both the Velociti® and CLIP™ protocols, the GWF-7075 panel does not support the CLIP protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL® Standard 268 7th Edition • Designed with a new profile to offer modern and improved aesthetics • Contains a built-in functional test switch activated by external magnet • Supports a low standby current • Provides rotary address switches (01-159) • Supplies optional relay, isolator, or sounder bases (standard or low frequency) • Includes dual LEDs for 360° visibility • Offers expanded color options 2 Ordering Information NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL" suffix indicates Black color model. NOTE: “WH” suffix indicates Bright White color model. ASD-PL3: Photoelectric smoke detector, bright white, Velociti ASD-PL3R: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, bright white, Velociti ASD-PTL3: Photoelectric smoke detector with thermal sensing, bright white, Velociti ASD-PL3-IV : Photoelectric smoke detector, ivory, Velociti/ CLIP ASD-PL3R-IV: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, ivory, Velociti/CLIP ASD-PTL3-IV : Photoelectric smoke detector with thermal sensing, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. Note: “IV” suffix indicates Flashscan and CLIP devices. “WH” suffix indicates bright white B501-WHITE: 4” Flangeless mounting base, bright white B501-WHITE-BP: 4” Flangeless mounting base bulk pack, bright white B501-IV: 4” Flangeless mounting base, ivory B300-6: 6” Flanged mounting base, bright white B300-6-IV: 6” Flanged mounting base, ivory B300-6-BP: 6” Flanged mounting base bulk (Pack of 10) B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, bright white B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory DNR: Intelligent duct detector housing, non-relay DNRW: Intelligent duct detector housing, non-relay, watertight Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6” Base, bright white TR300-IV: Accessory Flange Ring for B300 6” Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single-gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCSCOF Series detectors. (Pack of 10) CK300-BL: Black detector kit. (Pack of 10) CK300-IR-Bl: Black, detector color kit for use with MCSCOF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/ or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5-foot (1.524,m) sections. Velociti® Series 3 Detectors Technical Specifications 9020-0617 | K | 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, Velociti® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s Velociti® Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com SYSTEMS Photoelectric Intelligent Detector: Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.49 cm) installed in B300-6 base 4 inches (10.16 cm) installed in B501 base Shipping Weight: 3.4 oz (96.4 g) Operating Temperature Range: Photo: 32° F to 122° F (0° C to 50° C) Photo in Duct Applications: -4° F to 158° F (-20° C to 70° C) Photo with Thermal: 32° F to 100° F (0° C to 38° C) Operating Humidity Range: 10% to 93% non-condensing Rate-of-Rise Detection: Responds to greater than 15°F/minute or 135°F (8.3° C/minute or 57°C Air Velocity Range: 0 to 4,000 ft/min (0 to 1219.2 m/min) Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current (@ 24 VDC): 200 UA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.): 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 STANDARDS The Velociti® Series 3 Photoelectric Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2332 FM: 3023594 MEA FDNY: COA-219-02-E Vol. VI CSFM: 7272-1703:0501 ISO 9001 Certification Thermal Detector Velociti® Series 3 Detectors Thermal Detectors Addressable Devices Description The Gamewell-FCI, Velociti® Series 3 intelligent thermal detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 heat detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The thermal detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. Velociti Series 3 thermal detectors provide cost-effective, intelligent property protection using the following single thermistor: • ATD-L3 offers 135°F fixed thermal detection. • ATD-L3R offers 135°F fixed and rate-of-rise thermal detection. • ATD-L3H provides fixed high-temperature detection at 190°F . For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number that appears after the detector model. Note: The E3 Series® and S3 Series panels support both the Velociti® and CLIP™ protocols, and the GWF-7075 panel supports only the Velociti® protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL® 268 7th Edition • Designed with a new profile to offer modern and improved aesthetics • Contains a built-in functional test switch activated by an external magnet • Supports a low standby current • Provides rotary address switches (01-159) • Supplies optional relay, isolator, or sounder bases (standard or low frequency) •Includes dual LEDs used for 360° visibility • Offers expanded color options 2 Ordering Information NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL" suffix indicates Black color model. NOTE: “WH” suffix indicates Bright White color model. ATD-L3: Thermal heat detector, 135°F fixed, bright white, Velociti ATD-L3-IV: Thermal heat detector, 135°F fixed, ivory, Velociti/CLIP ATD-L3R: Thermal heat detector, 135°F rate of rise, bright white, Velociti ATD-L3R-IV: Thermal heat detector, 135°F rate of rise, ivory, Velociti/CLIP ATD-L3H: Thermal heat detector, 190°F high temp, bright white, Velociti ATD-L3H-IV: Thermal heat detector, 190°F high temp, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. B501-White: 4" Flangeless mounting base, bright white B501-White-BP: 4" Flangeless mounting base bulk pack, bright white B501-IV: 4" Flangeless mounting base, ivory B501-BL 4" Flangeless mounting base, B300-6: 6" Flanged mounting base, bright white B300-6-IV: 6" Flanged mounting base, ivory B300-6-BP: 6" Flanged mounting base bulk pack B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, bright white B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single-gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCS- COF Series detectors. (Pack of 10) CK300-BL: Black detector kit (Pack of 10) CK300-IR-Bl: Black, detector color kit for use with MCS- COF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5- foot (1.524,m) sections. Velociti® Series 3 Detectors Technical Specifications 9020-0620 | G | 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, Velociti® and Gamewell-FCI® are registered trademarks and CLIP™ is a trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s Velociti® Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com SYSTEMS Thermal Intelligent Detector Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.6 cm) installed in B300-6 base 4 inches (10.2 cm) installed in B501 base Shipping Weight: 3.4 oz (95 g) Operating Temperature Range: Thermal 135° F fixed: -4° F to 100° F (-20° C to 38° C) Thermal 135° F rate-of-rise: -4° F to 100° F (-20° C to 38° C) Thermal 190° F rate-of-rise: -4° F to 135° F (-20° C to 57° C) Operating Humidity Range: 10% to 93% non- condensing Rate-of-Rise Detection: : Responds to greater than 15°F/minute or 135°F (8.3° C/minute or 57°C Electrical Specifications Voltage Range: : 15 to 32 VDC Standby Current (@ 24 VDC): 200 uA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.): : 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): : 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: : 0.0063 STANDARDS The Velociti® Series 3 Thermal Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2332 FM: 3023594 MEA-FDNY: 219-02-E Vol. VI CSFM: 7270-1703-0502 ISO 9001 Certification Figure 1 B501 Mounting Base Figure 2 B210LP Mounting Base Figure 3 B224BI Mounting Base Figure 4 B224RB Mounting Base Intelligent Bases B501, B210LP, B224BI, B224RB and Mounting Kits and Accessories Addressable Devices General The Intelligent Velociti® and CLIP™ mounting bases and kits provide a variety of ways to install Gamewell-FCI detectors in any application. These mounting bases are non- addressable and are available in both the Velociti and CLIP protocols. The intelligent detectors can be mounted in any of the following devices, depending on the junction box selection (see Table 1 - Junction Box Selection Guide). •flanged bases • flangeless bases •plastic rings Note: The E3 Series® and S3 Series panels support both the Velociti® and CLIP™ protocols, and the GWF-7075 panel supports only the Velociti protocol. Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide one Form-C contact relay for the control of auxiliary functions such as door closure and elevator recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are available in a combination temporal 3 and continuous tone model. The Intelligent Bases provide a variety of mounting options to meet your installation challenges. The bases are available in flanged or flangeless versions, so that you can mount the bases to a variety of junction boxes. See Table 1 for the Junction Box Selection Guide. You can use the SMB600 surface mounting box to mount the following bases: • B210LP relay base • B224BI isolator base • B224RB relay base FEATURES & BENEFITS All sounder bases offer the following features. •Complies with UL® Standards 268 and 464 •Includes the following three types of bases that comply with local code requirements: - Relay - Isolator - Sounder Relay Base Feature • Relay bases provide one Form-C contact relay Isolator Base Feature • Isolator bases include data communications lines to operate under fault condition Installation Features The bases offer the following flexible installation characteristics: • Offers multiple accessory options • Includes an installation mounting kit and accessories for several types of model options • Uses 12-24 AWG gauge wire ranges to provide the bases with flexible installation • Contains bases that enable quick and secure detector plug-in • Provides SEMS screws for easy wiring connections • Available in temporal and non-temporal pattern versions 2 Ordering Information NOTE: “WH” suffix indicates Bright White color model. NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL" suffix indicates Black color model. Intelligent Bases B501-WHITE: Flangeless mounting base, bright white Dimensions: 4” (10.2 cm) diameter x 0.74” (18.8 mm) height B501-WHITE-BP: Flangeless mounting base bulk pack, bright white B501-IV: Standard European flangeless mounting base, ivory B501-BL: Standard European flangeless mounting base, black B224BI-WH: Plug-in Isolator detector base, bright white Dimensions: 6.85 (17.4 cm) diameter x 1.61” (4.1 cm) height B224BI-IV: Plug-in Isolator detector base, ivory B224RB-WH: Plug-in Relay detector base, bright white Dimensions: 6.85” (17.4 cm) diameter x 1.61” (4.1 cm) height B224RB-IV: Plug-in Relay detector base, ivory B300-6 : Standard flanged low-profile mounting base, white Dimensions: 6.1" (15.49 cm) diameter B300-6-BP: Bulk pack of B200-6 package contains 10 B300-6-IV: Standard flanged low-profile mounting base, ivory Ordering Information Mounting Kits and Accessories: BCK-200B: Detector kit, black CK300: Detector color kit, white Pack of 10 CK300-IR: Detector color kit for use with MCS-COF Series Detectors, white. Pack of 10 CK300-IV: Detector color kit, ivory. Pack of 10. CK300-IR-IV: Detector color kit for use with MCS-COF Series detectors, ivory. Pack of 10. CK300-BL: Detector color kit, black. Pack of 10. CK300-IR-Bl: Detector color kit for use with MCS-COF Series detectors, black. Pack of 10. TR300: Accessory flange ring for B300-6, bright white TR300-IV: Accessory flange ring for B300-6m ivory M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. RA100Z: Remote LED annunciator. 3-32 VDC. Mounts to a U.S. single-gang electrical box. For use with B401 and B300-6. SMB600: Surface mounting kit, flanged. TR300: Replacement flange for B210LP base, white TR300-IV: Replacement flange for B210LP base, ivory WCK-200B: Detector kit, white Mounting Kits and Accessories Table 1 lists the mounting kits and accessories assigned to each model. SINGLE- GANG 3.5" OCTAGONA L 4.0" OCTAGONA L 4.0" SQUARE 4.0" SQUARE WITH 3.0" MUD RING 50 MM 60 MM 70 MM 75 MM B501 No Yes No No Yes Yes Yes Yes No B210LP Yes Yes Yes Yes Yes No No No No B224BI No Yes Yes Yes Yes No Yes Yes Yes B224RB No Yes Yes Yes Yes No Yes Yes Yes NOTE: The box depth is contingent on the base and the wire size. For information on applicable local codes for appropriate recommendation, refer to the National Electrical Code. Table 1: Intelligent Bases Mounting Kits Intelligent Bases Technical Specifications 9021-60540 | J | 07/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx Gamewell-FCI®, E3 Series® and Velociti® are registered trademarks and Clip™ is a trademark of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. ULC® is a registered trademark of Underwriters Laboratories of Canada Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s Intelligent Bases and other products available by visiting www.Gamewell-FCI.com SYSTEM Temperature Range: For B224RB, B224BI, and B210LP: 32°F to 120°F (0°C to 49° C) For B210LP, B300-6, B501: -4° F to 150°F (-20°C to 66°C) Humidity Range: 10% to 93% RH, non-condensing Wire Gauge: For B224BI, B224RB: 14 to 24 AWG For B210LP, B300-6, B501: 12 to 24 AWG Electrical Ratings: For B501, B224RB, B224BI: Operating Voltage: 15 to 32 VDC (powered by SLC) Standby Ratings: B501: 150 uA B224BI: 450 uA maximum B224RB: 170 uA Set Time (B224RB only): Short delay: 55-90 m seconds Long delay: 6 to 9 seconds Reset Time (B224RB only): 20 m seconds maximum Relay Characteristics (B224RB only): Two-coil Latching Relay One Form-C Contact Ratings (UL/CSA): 0.9 A @ 125 VAC (resistive) 0.9 A @ 110 VDC (inductive) 3.0 A @ 30 VDC (resistive) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The Intelligent Bases are designed to comply with the following standards: UL Standards: UL 268 UL 464 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S911 FM: 3035027 CSFM: 7135-1653:0213 7300-1653:0109 7300-1653:0126 7300-1653:0238 ISO 9001 Certification