HomeMy WebLinkAboutEX13_P_Arch_Elevations_221028_v2PRELIMINARYSTATE OF WASHINGTONDAVID C. BOILEAUARCHITECTREGISTERED94061ST FINISH FLOOR
0"
2ND FINISH FLOOR
14' -0"
ABCDE
40' - 0"7' - 0"26' - 0"2' - 0"
EXISTING
BUILDING HEIGHT
31' -3"
PROPOSED
BUILDING HEIGHT
27' -9 7/8"
1ST FINISH FLOOR
0"
2ND FINISH FLOOR
14' -0"
1 2 3 4 5
10' - 0"22' - 0"33' - 0"30' - 6"
EXISTING
BUILDING HEIGHT
31' -3"
MASONRY TO MATCH
EXISTING
SUNSHADE TO
MATCH EXISTING
VERTICAL METAL
SIDING TO MATCH
EXISTING
STOREFRONT
WINDOW SYSTEM TO
MATCH EXISTING
PROPOSED
BUILDING HEIGHT
27' -9 7/8"
PROPOSED
BUILDING ADDITION
W4
1ST FINISH FLOOR
0"
2ND FINISH FLOOR
14' -0"
A B C D E
2' - 0"26' - 0"7' - 0"40' - 0"
EXISTING
BUILDING HEIGHT
31' -3"
MASONRY TO MATCH
EXISTING
STOREFRONT WINDOW
SYSTEM TO MATCH
EXISTING
SUNSHADE TO
MATCH EXISTING
VERTICAL METAL
SIDING TO MATCH
EXISTING
PROPOSED
BUILDING HEIGHT
27' -9 7/8"
PROPOSED BUILDING
ADDITION
W2
W1
1ST FINISH FLOOR
0"
2ND FINISH FLOOR
14' -0"
12345
10' - 0"22' - 0"33' - 0"30' - 6"
EXISTING
BUILDING HEIGHT
31' -3"
MASONRY TO MATCH
EXISTING
STOREFRONT WINDOW
SYSTEM TO MATCH
EXISTING
SUNSHADE TO
MATCH EXISTING
VERTICAL METAL
SIDING TO MATCH
EXISTING
PROPOSED
BUILDING HEIGHT
27' -9 7/8"
PROPOSED BUILDING
ADDITION
W3 W2
W1
STOREFRONT DOOR
FRAME PER SCHEULE
ELEVATION NOTES:
1. FOR GENERAL ARCHITECTURAL NOTES (GAN) SEE SHEET A0.2,
FOR GENERAL STRUCTURAL NOTES (GSN) SEE SHEET S0.1, FOR SPECIAL
INSPECTION TABLES SEE SHEET S0.2.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO SUBMITTAL OF
SHOP DRAWINGS. SHOP DRAWINGS WITHOUT FIELD VERIFICATION OF
DIMENSIONS SHALL BE REJECTED
ELEVATION LEGEND:
EXISTING LAP SIDING
EXISTING HORIZONTAL METAL SIDING
GROUND FACE CMU, PROPOSED
TO MATCH EXISTING
BOX RIB WALL PANEL, PROPOSED
TO MATCH EXISTING
PROJECT NO.
SHEET NO.PROJECTSHEET TITLEPREPARED FORPREPARED BYSEALAPPROVALS REVISIONSDRAFTERENGINEERPRINCIPALDATESCALEAS NOTEDPHONE: (253) 474-9449 | FAX: (253) 474-01534815 CENTER STREET | TACOMA, WA. 98409CIVIL | STRUCTURAL | SURVEYhttp://www.sittshill.com/19682
A6.0WA ST AUTO DEALERS ASSOC.BUILDING ADDITION AND T.I.621 SW GRADY WAY, RENTON, WA. 98057EXTERIOR ELEVATIONSWASHINGTON STATEAUTO DEALERS ASSOCIATION621 SOUTHWEST GRADY WAYRENTON, WA. 98057CONTACT: VICKI GILES FABRELGLDCB08/10/2022MCCSCALE: 1/8" = 1'-0"A EAST EXTERIOR ELEVATION (PARKING LOT)
SCALE: 1/8" = 1'-0"D SOUTH EXTERIOR ELEVATION (ALLEY)
SCALE: 1/8" = 1'-0"C WEST EXTERIOR ELEVATION (RAYMOND WAY)
SCALE: 1/8" = 1'-0"B NORTH EXTERIOR ELEVATION (GRADY WAY)PHONE: (206) 433-6300A75% DESIGN REVIEW SUBMITTAL09/29/2022