Loading...
HomeMy WebLinkAboutR-412723DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EEC F5B6-602A-4E4A-B436-A317AA638878 t Li DESIGNER TO SPECIFY WATER STORAGE ELEVATION OVERFLOW STRUCTURE PER STD. PLAN FOR EDGE TREATMENT OPTIONS, 262.40 UNLESS SPECIFIED OTHERWISE SEE STD. PLAN 262.20 OR LANDSCAPING JSIDEWALK BOTTOM WIDTH SIDE SLOPE 'f TREE, SEE NOTE 9 ROADWAYI V MIN. LOT MIN. 18" TOP OF BANK ' 6" MIN. B' MIN. PARKING _ ELEVATION `" 2% 2"-12" PONDING FREEBOARD y � DEPTH � 1° 1.5 - ' 25MIN. = ^ '2.5 MIN. " TRANSITION ZONE SOIL. / SEE STD. PLAN 262.20 t t ' A'# , r> .:• • r • ,_ •i�� jj:+ i��;.':��;4- `'#"'%•''; 2"4'DEPTH ARBORIST ,t.^„ ". / WOOD CHIP MULCH, �'�:,I•-'„ >.`, _�`_:'_'{"-Y' �� ANGLE OF REPOSE SEE NOTE 7 '� �(.• '1'' - :'VY. , '•"` BIORETENTION SOIL MIX (BSM), SEE NOTE 5 r� I 12' MIN. UNDERDRAIN AGGREGATE, SEE NOTE 6 OVERFLOW TO STORM MAIN / SCARIFIED AND UNCOMPACTED SUBGRADE, LOW PERMEABILITY LINER SEE NOTES 1 AND 2 WHEN REQUIRED, SEE NOTE 3 ' UNDERDRAIN, SEE NOTE 4 NOTES: GRAVEL BASE, SEE STO. PLAN 262.40 1. AVOID COMPACTION OF EXISTING SUBGRADE BELOW BASIN. 2. SCARIFY SUBGRADE TO A DEPTH OF 31NCHES MINIMUM IMMEDIATELY PRIOR TO PLACEMENT OF BIORETENTION SOIL MIX AND UNDERDRAIN AGGREGATE, EXCEPT WHEN LINER IS REQUIRED. 3. LINER TO BE INSTALLED ONLY WHEN REQUIRED IN THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM). LOW PERMEABILITY LINER TO BE 30 MIL MIN. GEOMEMBRANE LINER OR 12 INCHES MIN. (DRY) CLAY LINER. CLAY LINER TO BE COMPACTED TO 95% MINIMUM DRY DENSITY (ASTM D698), WITH AT LEAST 30% CLAY PARTICLES PASSING ASTM D422 AND AT LEAST 15% PLASTICITY INDEX ASTM D4318 . 4. UNDERDRAIN TO BE 6" MIN. (PRIVATE), 8" MIN. (PUBLIC) SLOTTED PVC PER ASTM D1785 SCH 40. SLOTS SHOULD BE CUT PERPENDICULAR TO THE LONG AXIS OF THE PIPE AND BE 0.04 TO 0.069 INCHES BY 1 INCH LONG AND BE SPACED 0.25 INCHES APART (SPACED LONGITUDINALLY). SLOTS SHOULD BE ARRANGED IN FOUR ROWS SPACED ON 45-DEGREE CENTERS AND COVER 112 OF THE CIRCUMFERENCE OF THE PIPE. SLOPE PIPE AT 0.5% MIN UNLESS OTHERWISE SPECIFIED. PROVIDE ONE CLEANOUT MIN. PER 100 FEET OF UNDERDRAIN, AND AT EACH END. SEE STD. PLAN 226.00. MATCH CROWN ELEVATION OF UNDERDRAIN TO OVERFLOW PIPE UNLESS OTHERWISE SPECIFIED. 5. 18' MIN. BIORETENTION SOIL MIX ON BOTTOM AND SIDES TO TOP OF PONDING AREA. BIORETENTION SOIL MIX TO MEET STD. PLAN 262.60. 6. UNDERDRAIN AGGREGATE TO MEET STD. PLAN 262.60. 7. ARBORIST WOOD CHIP MULCH TO MEET STD. PLAN 262.60. 8. MAXIMUM LONGITUDINAL SLOPE (ALONG DIRECTION OF FLOW) OF BIORETENTION SWALES SHALL BE 6%. 9. WHERE NOT CONFLICTING WITH REQUIRED CLEARANCES OR UTILITIES, TREES MAY BE LOCATED IN BIORETENTION. REDUCE BOTTOM WIDTH TO 6 INCHES MINIMUM AND INCREASE SIDE SLOPE TO 1.511:1V ADJACENT TO TREE. TREES TO BE LOCATED ONLY OUTSIDE OF LINER FOR LINED FACILITIES. GENERAL NOTES: 1. MINIMUM UTILITY SETBACKS AND PROTECTION MEASURES MUST CONFORM TO CURRENT CITY STANDARDS STD. FLANS 265.00 265.10 AND 265.20 AND OTHER UTILITY PROVIDER REQUIREMENTS. COORDINATE WITH CITY ENGINEER IN THE EVENT OF UTILITY CROSSINGS OR CONFLICTS. 2. BSM PLACEMENT, GRADING, AND CONSOLIDATION SHALL NOT OCCUR WHEN THE BSM IS EXCESSIVELY WET OR HAS BEEN SUBJECTED TO MORE THAN 112" OF PRECIPITATION WITHIN 48 HOURS PRIOR TO PLACEMENT. EXCESSIVELY WET IS DEFINED AS BEING AT OR ABOVE 22% SOIL MOISTURE BY A GENERAL TOOLS AND INSTRUMENTS DSMM50D PRECISION DIGITAL SOIL MOISTURE METER WITH PROBE (OR EQUIVALENT). THERE SHOULD BE NO VISIBLE FREE WATER IN THE MATERIAL. THE CONTRACTOR SHALL PLACE BSM LOOSELY WITH A CONVEYOR BELT OR WITH AN EXCAVATOR OR LOADER FROM A HEIGHT NO HIGHER THAN 6 FEET, UNLESS OTHERWISE APPROVED BY THE ENGINEER (I.E., DO NOT DUMP MATERIAL DIRECTLY FROM TRUCK INTO CELL). COMPACT BSM USING NON -MECHANICAL COMPACTION METHODS (E.G., BOOT PACKING, HAND TAMPING, OR WATER CONSOLIDATION) TO 83% (3 2%) OF THE MAXIMUM DRY DENSITY PER MODIFIED PROCTOR TEST (ASTM D1557), OR AS DIRECTED BY THE ENGINEER. 3. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TD SCALE (NTS) STD. PLAN - 262.10 �s PUBLIC WORKS BIORETENTION SECTION PPR D: "` DEPARTMENT (WITH UNDERDRAIN) GAZ 9/28/2018 I verk,adn�,aar,.0 DATE :45 AN BIORETENTION SECTION W/ UNDERDRAIN C6.7 NTS DocuSign Envelope ID: 6EEC F5B6-602A-4E4A-B436-A317AA638878 _ _ _ _ PLANTING ZONES, - _ _ _ _ _ SEE BELOW �I II I I ar•^✓�'3 I I I I I I I 2"4• DEPTH ARBORIST I I I I I WOOD CHIP MULCH, SEE STD. PLAN 262.60 BOTTOM WIDTH SIDE SLOPE AT MIN. 18' TREE, SEE NOTE 1 ROADWAY - -SIDEWALK OR LANDSCAPING 2"-1 Z' PONDING DE+yP-T.HH TRANSITION ZONE SOIL \ \ 4 :k,' `J,r�-:' ,� '�,E ;.,y,;� SEE STD. PLAN 262.20[=� 4 - 6'-MIN. "' = 1 L;•',�`��. �'. BIORETENTION SOIL MIX, ?'F' .e .7 -•ti �.,'ni- ,,nrM SEE STD. PLAN 262.60 SCARIFIED AND UNCOMPACTED SUBGRADE NOTES: 1. WHERE NOT CONFLICTING WITH REQUIRED CLEARANCES OR UTILITIES, TREES MAY BE LOCATED IN BIORETENTION. REDUCE BOTTOM WIDTH TO 6" MIN. AND INCREASE SIDE SLOPE TO 1.SH:1V ADJACENT TO TREE. TREES TO BE LOCATED ONLY OUTSIDE OF LINER FOR LINED FACILITIES. GENERAL NOTES: 1. ALL PLANTS SHALL BE SELECTED WITH A MAXIMUM MATURE HEIGHT NOT GREATER THAN 30-INCHES ABOVE THE TOP OF THE FACILITY, WITH THE EXCEPTION OF TREES AND ACCENT SHRUBS. 2. SEE STD. PLANS 262.00, 262.10, AND 262.20 FOR SECTION VIEWS OF SIORETENTION FACILITIES. 3. SEE THE CITY OF RENTON SURFACE WATER DESIGN MANUAL (RENTON SWDM) TABLE C2.6A FOR A SELECTION OF APPROVED WATER TOLERANT PLANTS. ADDITIONAL SPECIES ARE ALLOWED WITH CITY APPROVAL. 4. SELECT A MINIMUM OF 50% EVERGREEN PLANTS. 5. PLANTS ADJACENT TO STREET, DRIVEWAY, OR SIDEWALK SHALL BE SELECTED AND SPACED TO ALLOW ACCESS TO VEHICLES AND NOT IMPEDE PEDESTRIANS. 6. PLANTS SHALL BE SPACED TO ENSURE CLEAR ACCESS AND UNIMPEDED FLOW FROM INLETS, OUTLETS, AND OVERFLOWS. 7. CONTINUE MULCH FOR A MINIMUM OF 2-FEET PAST THE TOP OF BANK ELEVATION OR INSTALL LANDSCAPE EDGING IF FACILITY IS ADJACENT TO TURF. B. PLANTING DESIGN SHOULD MINIMIZE COMPACTION OF BIORETENTION SOIL MIX THROUGH PLANNED MAINTENANCE ACCESS. ANNUAL PLANTS REQUIRING SOIL DISTURBANCE FOR HARVESTING (E.G.. CARROTS) OR ANNUAL REPLANTING ARE NOT PERMITTED, 9. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. TABLE. PLANTING ZONES ZONE PLANT TYPE LOCATION EMERGENTS, PERENNIALS 8 LOW SHRUBS (PLANTS O THAT CAN TOLERATE STANDING WATER) FACILITY BOTTOM PERENNIALS 8 LOW SHRUBS (PLANTS OEMERGENTS, `Z THAT CAN TOLERATE OCCASIONAL STANDING LOWER SLOPE TO TOP OF PONDING WATER) OGROUNDCOVERS I SHRUBS UPPER SLOPE / SIDEWALK GRADE OOO APPROPRIATE SHRUB ACCENT SHRUBBASEL) SIDEWALK GRADE /LOWER SLOPE !FACILITY BOTTOM ON ZONE) OTREE UPPER SLOPE, SEE NOTE 1 UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 262.50 .� PUBLIC WORKS BIORETENTION PLANTING - APPR M D: DEPARTMENT SECTION VIEW GAZ 9/28/2018 1 �rwo,k,aamnxr„..r DATE BIORETENTION PLANTING .45 AN 6" MIN., SEE TOP OF BANK NOTE 1 ELEVATION CONCRETE CURB, SEE STD. PLAN 101 6" MIN. 1' FREEBOARD 2% ISTREET J � TOP OF PONDING IT III --III Is. 1 `\ TRANSITION ZONE SOIL, SEE NOTES 2 AND 3 1 2'4" DEPTH ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 / BIORETENTION SOIL MIX, SEE NOTE 4 J BIORETENTION ADJACENT TO CURB 6" MIN., SEE NOTE 1 SIDEWALK DRIVEWAY, OR 6" MIN. 1' DRIVING SURFACE FREEBOARD 2% TOP OF PONDING `- / a.' I-II6" I-11 - TRANSITION ZONE SOIL, SEE NOTES 2 AND 3 :•-;' - 2"4' DEPTH ARBORIST WOOD CHIP MULCH, SEE STD. PLAN 262.60 BIORETENTION SOIL MIX, SEE NOTE 4 BIORETENTION ADJACENT TO SIDEWALK, DRIVEWAY, OR DRIVING SURFACE WITH FLUSH OR NO CURB NOTES: 1. SHOULDER/LEVEL AREA WIDTH TO BE 6-INCH MIN. IN AREAS WITHOUT PARKING. PLANTINGS ADJACENT TO PARKING SHALL BE SELECTED AND SPACED TO ALLOW ACCESS TO VEHICLES. 2. COMPACT TRANSITION ZONE SOIL IMMEDIATELY BEHIND CURB TO 90%MAX. STANDARD PROCTOR DENSITY (ASTM D698). 3. TRANSITION ZONE SOIL SHALL BE BIORETENTION SOIL MIX OR AMENDED SOIL PER GENERAL NOTE 1. 4. 18" MINIMUM BIORETENTION SOIL MIX PER STD. PLAN 262.60 TO TOP OF PONDING DEPTH. GENERAL NOTES: 1. SOIL AMENDMENT: SCARIFY OR TILL SUBGRADE TO 3-INCH DEPTH. PLACE 3-INCHES OF TOPSOIL ON SURFACE AND TILL INTO 5-INCHES OF SITE SOIL. SCARIFICATION DOES NOT APPLY TO LINED FACILITIES. TOPSOIL SHALL HAVE A MINIMUM ORGANIC MATTER CONTENT OF 10% DRY WEIGHT IN PLANTING BEDS AND 5% IN TURF AREAS. AND A PH FROM 6.0 TO &0 OR MATCHING THE PH OF THE ORIGINAL UNDISTURBED SOIL. 2. SEE STD. PLAN 262.30 FOR CURB CUTS. 3. FOR FACILITIES WITH LINERS, PROVIDE LINER ANCHOR PER WSDOT SPECIFICATIONS B-29.3(2). 4. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOT TD SCALE (NTS) STD. PLAN - 262.20 [1,R) PUBLIC WORKS APPROVED: 1, DEPARTMENT BIORETENTION - EDGE TREATMENTS GAZ 9/28/2018 I vmk,adnmia„,v DATE BIORETENTION - EDGE TREATMENTS 6.7 NTS DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 UNDERDRAIN AGGREGATE TABLE: UNDERDRAIN AGGREGATE GRADATION SIEVE SIZE 3M-INCH PERCENT PASSING 10O PERCENT 1/4-INCH 30 TO 60 PERCENT U.S. NO.8 20 TO 50 PERCENT U.S. NO. 50 3 TO 12 PERCENT U.S. NO. 200 0 TO 1 PERCENT UNDERDRAIN AGGREGATE MUST CONSIST OF SCREENED SAND, GRAVEL OR OTHER INERT MATERIALS, OR COMBINATIONS THEREOF, FROM SOURCES APPROVED BY THE ENGINEER, HAVING HARD, DURABLE PARTICLES FREE FROM ADHERENT COATINGS. THE MATERIALS MUST BE WASHED THOROUGHLY TO REMOVE CLAY, LOAM, ALKALI, ORGANIC MATTER, OR OTHER DELETERIOUS SUBSTANCES. PARTICLES HAVING A SPECIFIC GRAVITY LESS THAN 1.95 MUST NOT EXCEED 1.0 PERCENT OF THE TOTAL WEIGHT. ORGANIC MATTER, BY CALORIMETRIC TEST, MUST NOT BE DARKER THAN THE REFERENCE STANDARD COLOR (ORGANIC PLATE NO. 3) AASHTO T21 UNLESS OTHER TESTS PROVE A DARKER COLOR TO BE HARMLESS. BIORETENTION SOIL MIX BIORETENTION SOIL MIX (BSM) SHALL BE A WELL -BLENDED HOMOGENEOUS MIXTURE OF 60 TO 65 PERCENT BY VOLUME MINERAL AGGREGATE FOR BIORETENTION SOIL AND 35 TO 40 PERCENT BY VOLUME COMPOST AS DETAILED IN THE TABLES BELOW. MINERAL AGGREGATE FOR BIORETENTION SOIL TABLE: MINERAL AGGREGATE GRADATION SIEVE SIZE PERCENT PASSING 318-INCH 100 PERCENT U.S. NO. 4 95 TO 100 PERCENT U.S. NO. 10 75 TO 90 PERCENT U.S. NO. 40 25 TO 40 PERCENT U.S. NO. 100 4 TO 10 PERCENT U.S. NO. 200 2 TO 4 PERCENT MINERAL AGGREGATE FOR BIORETENTION SOIL MUST BE FREE OF WOOD WASTE, COATING, OR ANY OTHER DELETERIOUS MATERIAL, AND ALL AGGREGATE PASSING THE NO. 200 SIEVE SIZE MUST BE NON -PLASTIC. MINERAL AGGREGATE MUST BE ANALYZED BY AN ACCREDITED LAB USING THE SIEVE SIZES NOTED IN THE TABLE TO THE LEFT, AND MUST MEET THE REQUIRED GRADATIONS. COMPOST TABLE: COMPOST GRADATION SIEVE SIZE MIN. PERCENT PASSING 2-INCH 100 PERCENT 1-INCH 99 PERCENT 5/8-INCH 90 PERCENT 114-INCH 75 PERCENT COMPOST MUST ORIGINATE A MINIMUM 65 PERCENT BY VOLUME FROM RECYCLED PLANT WASTE COMPRISED OF YARD DEBRIS, CROP RESIDUES, AND BULKING AGENTS, AND MEET THE DEFINITION OF "COMPOSTED MATERIAL" IN WAC 173-35D-100. COMPOST SHALL HAVE A MOISTURE CONTENT THAT HAS NO VISIBLE FREE WATER OR DUST PRODUCED WHEN HANDLING THE MATERIAL. COMPOST SHALL HAVE AN ORGANIC MATTER CONTENT OF 40 PERCENT TO 65 PERCENT BY DRY WEIGHT, A CARBON TO NITROGEN RATIO BELOW 25:1, AND A PH BETWEEN 6.0 AND 8.0 ABORIST WOOD CHIP MULCH TABLE: AR13ORIST WOOD CHIP MULCH GRADATION SIEVE SIZE PERCENT PASSING 6-INCH 100 PERCENT 2-INCH 95 TO 100 PERCENT 1-INCH 70 TO 100 PERCENT 518-INCH 0 TO 50 PERCENT U.S. NO. 4 0 TO 30 PERCENT ARBORIST WOOD CHIP MULCH SHALL BE COARSE GROUND WOOD CHIPS (APPROXIMATELY 1/2" TO T ALONG THE LONGEST DIMENSION) DERIVED FROM THE MECHANICAL GRINDING OR SHREDDING OF THE ABOVE -GROUND PORTIONS OF TREES. IT MAY CONTAIN WOOD, WOOD FIBER, BARK, BRANCHES, AND LEAVES, BUT MAY NOT CONTAIN WEEDS. WEED SEEDS, OR VISIBLE AMOUNTS OF SOIL. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS) UNDERDRAIN AGGREGATE, [PROVID: STD. PLAN-262.60 DEPARTMENT GAZ PUBLIC WORKS BIORETENTION SOIL MIX, AND MULCH 9/28/2018 1 SPECIFICATIONS vork,aa,n.ay,".0 DATE QIr1QCTCA1TIr1A1 Ann /G�r111 1► AIY C+�CnC+ NTS C6.7 NTS cPm*ote r r a ENGINEERING PLLC 321 3rd Ave South, Suite 406 Seattle, Washington 98104 ph 206.596.7115 J coterraengineering.com U_ :45 AN MATCH GUTTER MATCH CURB WIDTH WIDTH 11 ' �• 12" MIN. STREAMBED 6" COBBLES. y Q ° SEE NOTE 3 OOOO a Q��Q� O Q rc < JAPER, o \O . TA(TYP.) s' �lJ1Q�V -T 18•_24••• a oO O\OO DESIGNER TO SPECIFY, e 12• . SEE NOTE 2 ' INFLOW-.> ° OO QQO�QO QQO�OOQ Vy . xJ A ° ae O\ �OOOO �oOo -6" MIN. Q n Q0 Q �l • 6' MIN. APE•R UTTER AT CUR13 CUT TO MATCH GUTTER SLOPE UPSLOPE AND DOWNSLOPE OF CURB CUT PLAN T GUTTER DEPRESSION AT FLOWLINE GUTTER UPSLOPE AND TYPICAL SIDE SLOPE DOWNSLOPE OF CURB CUT - - - - - 2"-4" ARBORIST WOOD CHIP SLOPE �2.5 MULCH SEE STD. PLAN 262.60 INFLOW 6" MIN. FREEBOARD ��1 V ROADWAY ° \ e • � 1" DROP TO COBBLES 8' 18" � _ ¢ 1 �l' f.1'%�.'•.'^;1'-d"� � X: :.-4'=� `T„f1 ., 1 ,• 4'CRUSHED SUkFACING �\ , �, ti_• 11 1,d, L, TOP COURSE �-z-E. ^Y.cI �,,, BIORETENTION FACILITY-, COMPACT SOIL BELOW4,,,); COBBLES SEE NOTE 4 // // // �- J' ~ Tg •Cs r-,S_u. .'i_ P >`1 -` \j\\j\\j\/ 8"MIN. ~i �. ��'_ Ste✓`- '` NOTES: SECTION A UNCOMPACTED BIORETENTION SOIL I MIX (BSM), SEE STD. PLAN 262.60 1. SEE STD. PLAN 262.20 FOR EDGE TREATMENT OUTSIDE INLET AREA. 2. INLET CURB CUT WIDTH SHALL BE 24' ON GUTTER SLOPES 2 5%AND 18" ON GUTTER SLOPES, 5%. 3. STREAMBED COBBLES SHALL BE 6" COBBLES PER WSDOT 9-03.11(2). COBBLE PAD TO BE 8' THICK, WITH 1:1 SIDE SLOPES, TAPERING TO 12" WIDE AT FACILITY BOTTOM. 4. COMPACT BIORETENTION SOIL MIX UNDER COBBLES TO 90% MAX STANDARD PROCTOR DENSITY (ASTM D698). GENERAL NOTES: 1. BOND NEW CURB AND GUTTER TO EXISTING CURB AND GUTTER WITH EPDXY AND DOWEL CONNECTION, IF RETROFITTING INTO EXISTING CURBLINE. REFER TO STD. PLAN 101.10 FOR EXPANSION JOINT DETAIL. 2. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOTTD SCALE (NTS) STD. PLAN - 262.30 • PUBLIC WORKS BIORETENTION - CURB CUT INLETS PPR D. DEPARTMENT GAZ 9/28/2018 I vmk,Adnnia DATE BIORETENTION - CURB CUT INLETS NTS 8" CLEANOUT :45 AM PRE-TREATMENT CELL 18.2' CAST IRON BEEHIVE GRATE AND FRAME, SEE NOTE 1 - OPTIONAL W OR 8" STREAMBED COBBLES, PER WSDOT 9-03.11(2), SEE NOTE 2 - SEE NOTE 3- VARIES , 5 MAX. I SEE NOTE = ITYP.j STORM DRAIN PIPE, DESIGNER TO SPECIFY 6" MIN. - 6" MIN. 6' MIN. -1 F 12" MIN. SUMP CATCH BASIN ADJUSTMENT SECTION AS REQUIRED, DESIGNER TO SPECIFY ELEVATION DESIGN PONDING ELEVATION UNDERDRAIN PIPE, IF REQUIRED, SEE STD. PLAN 262.10 CATCH BASIN TYPE 1 PER STD. PLAN 200.00 OR OTHER STRUCTURE WITH APPROVAL CONCRETE BASE GRAVEL BACKFILL FOR DRAINS COMPACT PER WSDOT STD. SPEC. 9-03.12 4 NOTES: 1. FRAME AND GRATE SHALL BE LOCKING AND GRATE SHALL BE BOLTED TO FRAME. FRAME SHALL CONFORM TO WSDOT STANDARD PLAN 8-30.10-01. GRATE TO BE DUCTILE IRON BEEHIVE GRATE FITTING 20"x24" FRAME. OLYMPIC FOUNDRY PART SM60BH OR EQUAL. SEE STANDARD SPECIFICATIONS 9-05.15(2) . 2. MINIMUM STREAMBED COBBLE DIAMETER SHALL BE LARGER THAN MAXIMUM GRATE OPENING. 3. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES, 4. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE. USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. GENERAL NOTES: 1. PLANT SPACING WITHIN FACILITY TO ALLOW MAINTENANCE ACCESS TO STRUCTURE. 2. 12-INCH MIN. CLEARANCE WITHIN OVERFLOW STRUCTURE SHALL BE PROVIDED FOR MAINTENANCE ACCESS. 3. OVERFLOW PIPES MUST BE LOCATED AT AN ELEVATION HIGHER THAN THE STORM DRAIN HYDRAULIC GRADE LINE TO PREVENT BACKFLOW INTO THE BIORETENTION FACILITY, 4. OVERFLOW STRUCTURE SHALL BE LOCATED WITHIN 10 FEET OF ROAD EDGE FOR MAINTENANCE ACCESS, UNLESS APPROVED OTHERWISE. OVERFLOW STRUCTURE MAY BE LOCATED IN SIDE SLOPES. S. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING 15 NOT TD SCALE (NTS) STD. PLAN - 262.40 ��• PUBLIC WORKS BIORETENTION - OVERFLOW OUTLET [PPRRED: "` DEPARTMENT STRUCTURE GAZ 9/28/2018 1 wmk,aen,neo-"mr DATE :45 AN J BIORETENTION - OVERFLOW OUTLET STRUCTURE Q NTS TREATMENT CELL 36.4' NOTES:1. DO NOT COMPACT SUBGRADE. SCARIFY P1Q0N $1FNU'SOIEW RECORD DRAWING THE INFORMATION ON THIS DRAWING INDICATES CHANGES MADE TO THE CONSTRUCTION DOCUMENTS BASED UPON BIORETENTION SWALE LONGITUDINAL SE BUILT SURVEY PREPARED BY TPO NTS INC., DATED 12/10/21, AND TRANSFERRED TO THE REPRODUCIBLE DRAWINGS BY THE ENGINEER. SURVEYED: SCALE: 1"=20' VERTICAL CITY O F HORIZONTAL- NAD AD 1983/183/1991 c DESIGNED: HS DRAWN: HS - RENTON ONE INCH DATU M CHECKED: PA AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH NO. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY :45 AN 7 vi U O O TTI V� T J li o O O C c O W LO T rn� V / 0.5' MIN FREEBOARD W \/\/ RIM ELEV: 340.28 7 ... v's.• \ BOTTOM OF SWU ^ 0 340.03 L- TTOM OF BIORETENTION SOIL U \ ELEV. 338.53 TOP OF 8" UNDERDRAIN PIPE: 338.36 L� 8" UNDERDRAIN IE:337.70/r^J v / Z BOTTOM OF UNDERDRAIN AGGREGATE 337.53 O EX 18" SD PIPE J RELOCATE AND REUSE EX TYPE 1 - CATCH BASIN ADJUST RIM AND INVERT PER PLAN \ REPLACE EX GRATE W/ BEEHIVE GRATE U R-412722 z IN COMPLIANCE WITH CITY OF RENTON STANDARDS w SUNSET OAKS APARTMENTS SUNSET LANE NE, RENTON, WA CITY OF RENTON CML DETAILS rr a Q U) Q O DATE: 10/5/20 � I ' FIELDBOOK: PAGE: V i Z DRAWING NO: C6.7 r /'\ �/ SHEET: OF: 22 36