Loading...
HomeMy WebLinkAboutMFP23000561DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23000561 IVR Number: 23000561 Permit Information Permit Name: P.034339 Address/Location:02/01/2023Application Date:0850220000Parcel Number: 1100 OAKESDALE AVE SW Permit Type:02/08/2023Issue Date:Franchise Permit Work Class:02/08/2024Expiration Date:Minor Utility Job Number: P.034339Franchise Type:Telephone Description: Lumen to access MH207, MH207 1, MH293, MH227, MH113, MH110, MH665, MH669, and MH670. This will not be a disturbance of surface. Restorations per City of Renton Standards Contacts Name Address PhoneTypeBilling Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549ApplicantX Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549Contact Jesse Patjens CenturyLink / Lumen 23315 66th Ave S Kent, WA 98032 Contact Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering Northsky Communications Tawnya Longfellow 22517 88th ave S Kent/WA 98031 P.034339 1100 Oakesdale Ave SW 3/1/2023 4/1/2023 Lumen to access MH207, MH207-1, MH293, MH227, MH113, MH110, MH665, MH669, and MH670 This will not be a disturbance of surface. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Austin Sweeney Austin Sweeney 2/1/2023 Date:9/13/2022 Author:Sharon Martos, Traffic Control Supervisor Project:P.045778 C.45CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Arrowboard (Chevron) Cone S Spotter Work Area Work Truck TRAFFIC CONTROL PLAN JOB # P.045778 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60NOT TO SCALE Sharon Martos Project # P.045778 C.45Designed for LUMENSharon MartosApproved 9/13/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.comROADWORKAHEADW20-1SW 7TH ST @ HARDIE AVE SW MH 113 RIGHT LANE CLOSURE RIGHT LANECLOSEDAHEADW20-5W4-2SW 7TH ST LIND AVE SWComments: ACCESS MH 113. SOUTH SIDE OF SW 7TH ST, WEST OF HARDIE AVE SW. RIGHT LANE CLOSURE.SIDEWALK CLOSED. CURB RAMPED AND NON-SKID STEEL PLATES PLACEDPER ADA REQUIREMENTS TO ACCOMMODATE PEDESTRIANS. SPOTTER WILL ASSIST PEDESTRIANS.RRRRDETOURM4-9bDETOURM4-9bDWY ROADWORKAHEADW20-1ROADWORKAHEAD W20-1 DWY DWY DWY ACCESS RDACCESS RD200'200'200'150'HARDIE AVE SWMH 113WORK AREA 10 X 190 NSPEEDLIMIT 30 S www.invarion.com Date:9/13/2022 Author:Sharon Martos, Traffic Control Supervisor Project:P.045778 C.45 CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Arrowboard (Chevron) Cone S Spotter truck Work Area TRAFFIC CONTROL PLAN JOB # P.045778 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60NOT TO SCALE Sharon Martos Project # P.045778 C.45Designed for LUMENSharon MartosApproved 9/13/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com S GRADY WAY @ TALBOT RD S MH 207 RIGHT LANE CLOSURE Comments: ACCESS MH 207 NE QUADRANT S GRADY WAY & TALBOT RD S..RIGHT LANE CLOSURE.CROSSWALK ACCESSIBLE.SPOTTER WILL ASSIST PEDESTRIANS. SPEEDLIMIT35 S S GRADY WAYTALBOT RD SWILLIAMS AVE S WELLS AVE S DWY ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEAD W20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1350'350'350'225'NMH 207 WORK AREA11 X 265 www.invarion.com Date:9/13/2022 Author:Sharon Martos, Traffic Control Supervisor Project:P.045778 C.45 CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.2. Channelizing devices are 28" traffic cones with retroreflective material.3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Arrowboard (Chevron) Cone S Spotter truck Work Area TRAFFIC CONTROL PLAN JOB # P.045778 C.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60NOT TO SCALE Sharon Martos Project # P.045778 C.45Designed for LUMENSharon MartosApproved 9/13/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com S GRADY WAY @ TALBOT RD S MH 207-1 RIGHT LANE CLOSURE Comments: ACCESS MH 207-1NE QUADRANT S GRADY WAY & TALBOT RD S..RIGHT LANE CLOSURE.CROSSWALK NORTH SIDE S GRADY WAY CLOSED.PEDESTRIANS ROUTED AROUND WORK AREA.SPOTTER WILL ASSIST PEDESTRIANS. SPEEDLIMIT35 S S GRADY WAY TALBOT RD SWILLIAMS AVE S WELLS AVE S DWY ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEAD W20-1ROADWORKAHEADW20-1ROADWORKAHEADW20-1350'350'350'225'CROSSWALK CLOSEDCROSS HERECROSSWALK CLOSEDCROSS HERENMH 207-1 WORK AREA11 X 265 www.invarion.com SW 7TH ST @ RAINIER AVE S MH-227 ACCESS LANE-SHIFT / LEFT-TURN-LANE CLOSURE Comments: ACCESS MH-227 LOCATED IN ROADWAY. LANE-SHIFT EASTBOUND S 7TH ST. LEFT-TURN LANE CLOSED RAINIER AVE S. DRIVEWAYS REMAIN OPEN/ACCESSIBLE. SIDEWALKS REMAIN OPEN/ACCESSIBLE. TRAFFIC CONTROL PLAN JOB # P. 045778. C. 45 PERMIT #DRIVEWAYDRIVEWAY1111111111111111 11111111111111 LEGEND ARROW BOARD CONES CROSSWALK TRAFFIC LIGHT WORK AREA WORK TRUCK 11 11 11 DRIVEWAYRAINIER AVE S SW 7TH STHARDIE AVE SWHARDIE AVE SWSIDEWALK SIDEWALK 24 12 12 ISLAND SIDEWALK 1111111111MH-227 ACCESSDRIVEWAYARROW BOARD PLACE IN ADVANCE OF WORK ZONE 350' +-350' +-350' +-ROADWORKAHEADW20-1LEFT TURN-LANECLOSEDAHEADN S 7TH STW1-4W12-1W20-1ROADWORKAHEAD200'200'LANESHIFTAHEADW5-5W2 0 - 1 RO A D WO R K AH E A D 350'W20-1ROADWORKAHEAD100'1111111111SHIFTINGTAPER 85' WORK ZONE11' X ~200' Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 25 / 30 20' 40'35 / 45 30' 60' ONE-LANE TWO-WAY TAPER 50' TO 100' NOT TO SCALE Comments: MERGING TAPER LENGTHTAPER ("L") LANE WIDTHL MPH 10' 11' 12' SHIFTING 20 70 75 80 TAPER 25 105 115 1651/2 L 30 150 165 18035 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 540 1/3 L 50 500 550 600 UNLAWFUL FOR ANYONE (OTHER THAN CITY OF RENTON) TO ALTERTHIS CERTIFIED PLAN WITHOUT EXPRESS WRITTEN CONSENT FROM:JEFFREY D. HUBBARD, TCS# 011989, JHUBBARD.TCP@GMAIL.COM Comments: SIGN SPACINGMPH "X" 20-25 100' 30 200' 35-40 350' 45+ 500'Jeffrey Hubbard Designed For: LUMEN Project # P. 045778. C. 45 Jeffrey D. Hubbard Traffic Control Supervisor WA TCS # 011989 Draw Date: 9/13/2022 Phone 253-737-5198 jhubbard.tcp@gmail.com _______________________ Date:9/13/2022 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:P. 045778. C. 45CERT:WA TCS # 011989 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements. 2. Channelizing devices are 28" traffic cones with retro reflective material. 3. All signs are 36" x 36" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be determined by City of RENTON. SPEEDLIMIT 30 SPEEDLIMIT 35 SPEEDLIMIT 35 SPEEDLIMIT 25 www.invarion.com Date:10/7/2022 Author:Sharon Martos, Traffic Control Supervisor Project:P.031075 E.45 CERT:TCS # 012843 Designed for LUMEN:By: SHARON MARTOS (DO NOT ALTER) Comments: General Requirements1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses.5. Crew is required to leave a minimum of 11' for lane width.6. Work hours will be determined by City of Renton. ONE LANE TWO WAY TAPER 50' MIN/100' MAX Legend Cone S Spotter Work Area Work Truck TRAFFIC CONTROL PLAN JOB # P.031075 E.45 PERMIT # CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60NOT TO SCALE Sharon Martos Project # P.031075 C.45Designed for LUMENSharon MartosApproved 10/7/2022Traffic Control SupervisorTCS # 012843Expires 5/31/2025Phone 253-737-5198sharon.martos@gmail.com UNLAWFUL FOR ANYONE OTHER THAN CITY OF RENTONTO ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 012843 sharon.martos@gmail.com S 7TH ST @ TALBOT RD S MH 293 RIGHT LANE CLOSURE Comments: ACCESS MH 293 SOUTH SIDE OF S 7TH ST, WEST OF TALBOT RD S.RIGHT LANE CLOSURE. RIGHT TURNS REMAIN ACCESSIBLE.SIDEWALK IS ACCESSIBLE.SPOTTER WILL ASSIST PEDESTRIANS.ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEAD W20-1 ROADWORKAHEADW20-1S 7TH ST TALBOT RD SSMITHERS AVE SBURNETT AVE SRIGHT LANECLOSEDAHEADW20-5MH 293 WORK AREA10 X 150W1-4100'100'100'105' SPEEDLIMIT 25 S NMORRIS AVE Swww.invarion.com NACHES AV E S W SW 7TH ST SW 7 T H S T SW 7TH ST O A K E S D A L E A V E S W OAKESDALE AVE SWTRAFFIC CONTROL PLAN JOB # P.045778.C.45 PERMIT # Legend CONES WORK TRUCK Arrowboard (Chevron) MANHOLE WORK AREA SPOTTER ONE LANE TWO WAY TAPER 50' MIN/100' MAX Date:9/14/2022 Author:Darlene Durr, Traffic Control Supervisor Project:P.045778.C.45 CERT:TCS # 011915 LUMEN:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be DETERMINED BY CITY, COUNTY AND/OR WSDOT. UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 Approved 9/14/2022Darlene Durr TCS # 011915 Phone 253-737-5198darlene.durr@hotmail.com _______________________Darlene Durr NOT TO SCALE NOTE ALL LANE WIDTHS ARE ESTIMATES; FOR ACCURANCY, MEASURE IN FIELD PRIOR TO WORK. REFER TO CHARTS FOR DEVICE SPACING, SIGNAGE SPACING, SIGN SIZE, BUFFER SPACING AND TAPER LENGTHS. MH 665 WORK AREA10' X 200' S ROADWORKAHEADROADWORKAHEADROADWORKAHEAD ROADWORKAHEADSPEEDLIMIT25 SPEEDLIMIT30SPEEDLIMIT 35SPEEDLIMIT35 N Comments: THIS IS TO ACCESS MH 665. THIS IS A RIGHT LANE CLOSURE. SIDEWALK IS ACCESSIBLE AT WORK AREA. SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA. SW 7TH ST @ OAKESDALE AVE SW MH 665 ACCESS RIGHT LANE CLOSURE www.invarion.com OAKESDALE AVE SW @ SW 7TH ST MH-669 ACCESS RIGHT-LANE CLOSURE TRAFFIC CONTROL PLAN JOB # P. 045778. C. 45 PERMIT # Comments: ACCESS MH-669 LOCATED OFF ROADWAY. RIGHT-LANE CLOSURE NORTHBOUND OAKESDALE AVE SW. ARROW BOARD USED. DRIVEWAYS REMAIN OPEN/ACCESSIBLE. SIDEWALKS REMAIN OPEN/ACCESSIBLE. SPOTTER WILL ASSIST AT WORK AREA. ISLAND ISLAND SPOTTERS OAKESDALE AVE SW OAKESDALE AVE SW SW 7TH ST ~200' ARROW BOARD MERGING TAPER 11 x ~225' 350' +-350' +-ROADWORKAHEADW20-1RIGHT LANECLOSEDAHEADW20-5W4-2DRIVEWAYDRIVEWAYMH-669 ACCESS WORK ZONE 11' X ~400' (TOTAL)NSPEED LIMIT 35 350' +-ROADWORKAHEADW20-1LEGEND ARROW BOARD CONES S SPOTTER WORK AREA WORK TRUCK SIDEWALK 1111111111111111Jeffrey Hubbard Comments: CHANNELIZATION SPACING MPH TAPER TANGENT 25 / 30 20' 40' 35 / 45 30' 60' ONE-LANE TWO-WAY TAPER 50' TO 100' NOT TO SCALE Comments: MERGING TAPER LENGTHTAPER ("L") LANE WIDTHL MPH 10' 11' 12'SHIFTING 20 70 75 80 TAPER 25 105 115 165 1/2 L 30 150 165 18035 205 225 245SHOULDER 40 270 295 320TAPER 45 450 495 5401/3 L 50 500 550 600 Designed For: LUMEN Project # P. 045778. C. 45 Jeffrey D. Hubbard Traffic Control Supervisor WA TCS # 011989 Draw Date: 9/13/2022 Phone 253-737-5198 jhubbard.tcp@gmail.com _______________________ Date:9/13/2022 Author:Jeffrey D. Hubbard, Traffic Control Supervisor Project:P. 045778. C. 45 CERT:WA TCS # 011989 LUMEN:Certified Traffic Control Plan LOCATION:RENTON, WA Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and City of RENTON Requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 36" x 36" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width. 6. Work hours will be determined by City of RENTON. UNLAWFUL FOR ANYONE (OTHER THAN CITY OF RENTON) TO ALTERTHIS CERTIFIED PLAN WITHOUT EXPRESS WRITTEN CONSENT FROM:JEFFREY D. HUBBARD, TCS# 011989, JHUBBARD.TCP@GMAIL.COM Comments: SIGN SPACINGMPH "X"20-25 100'30 200' 35-40 350' 45+ 500' www.invarion.com TRAFFIC CONTROL PLAN JOB # P.034339 E.45 PERMIT # Legend MANHOLE CONES WORK TRUCK Arrowboard (Chevron) WORK AREA SPOTTER ONE LANE TWO WAY TAPER 50' MIN/100' MAX Date:1/20/2023 Author:Darlene Durr, Traffic Control Supervisor Project:P.034339 E.45 CERT:TCS # 011915 LUMEN:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be DETERMINED BY CITY, COUNTY AND/OR WSDOT. UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: DARLENE DURR, TCS #011915, darlene.durr@hotmail.com CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/70 35/45 25/30 40 40 30 20 80 60 Approved 1/20/2023Darlene Durr TCS # 011915 Phone 253-737-5198darlene.durr@hotmail.com _______________________Darlene Durr NOT TO SCALE NOTE ALL LANE WIDTHS ARE ESTIMATES; FOR ACCURANCY, MEASURE IN FIELD PRIOR TO WORK. REFER TO CHARTS FOR DEVICE SPACING, SIGNAGE SPACING, SIGN SIZE, BUFFER SPACING AND TAPER LENGTHS. MERGING TAPER 225'ROADWORKAHEADROADWORKAHEADRIGHT LANECLOSEDAHEADMH 670 S 350' 350' 350' 350'SPEEDLIMIT35SPEEDLIMIT35 OAKESDALE AVE SW OAKESDALE AVE SWROADWORKAHEAD ROADWORKAHEAD 350' 350' WORK AREA 11' X 300'SW GRADY WAYSW GRADY WAYComments: THIS IS TO ACCESS MH 670. THIS IS A RIGHT LANE CLOSURE. SIDEWALK IS ACCESSIBLE AT WORK AREA. SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA.DRIVEWAYS REMAIN ACCESSIBLE AT WORK AREA.NOAKESDALE AVE SW @ SW GRADY WAY MH 670 ACCESS RIGHT LANE CLOSURE S www.invarion.com NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.10400000000”NVICINITY MAPCUSTOMER NAME: BAKER HUGHES COMPANYLCON: BILLY NUGIERPHONE NO: 713-913-7454EMAIL:  billy.nugier@bakerhughes.comPROJECT ID:  A.2932939ORDER #: N29189824ARMOR OR DSR #: 1007-2260898REVISION # SHEET # REASON FOR REVISION REVISED BY DATEREVISION 1 1 NEW CUSTOMER INFO ONLY SL 11/04/22REVISION 2 ALL NEW SOW, NEW DWGS ADDING 8 MH, NEW V-MAP & NOTES SL 11/22/22SCOPE OF WORK:POF: @ MANHOLE 207-1, SPLICE COUNT WITH LRE25, 169-180 FROM [SE94] ONTO [A3M6S] FALLING TO MANHOLE 207. @ MANHOLE 207, SPLICE COUNTFROM [A3M6S] ONTO [A3G4E] FALLING TO MANHOLE 293. @ MANHOLE 293, SPLICE COUNT FROM [A3G4E] ONTO [A3M6T] FALLING TO MANHOLE 227.@ MANHOLE 227, SPLICE COUNT FROM [A3M6T] ONTO [A3LZX] FALLING TO MANHOLE 113. @ MANHOLE 113, SPLICE COUNT FROM [A3LZX] ONTO [UA68]FALLING TO MANHOLE 110. @ MANHOLE 110, SPLICE COUNT FROM [UA68] ONTO [A3LQ5] FALLING TO MANHOLE 665. @ MANHOLE 665, PLACE NEW 48COUNT FIBER IN EXISTING CONDUIT THRU MANHOLE 669 & THEN TO MANHOLE 670. @ MANHOLE 670, SPLICE COUNT FROM NEW 48 FOC ONTO [A2YK9]FALLING TO CUSTOMER'S BUILDING MPOP. @ CUSTOMER MPOP, THIS WILL BE A 2nd UPLINK ON EXISTING EQUIPMENT & TERMINATE LRE25, 265-266 IN FDP.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 07/22/2223N4E24P.034339W26226RNTNWA011100 OAKESDALE AVE SWRENTON, WA 9805719FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400EMAIL: jeremiah.scherer@lumen.comR TTEE CATV CATV CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L R/W R/W R/W P/L P/L B/C B/C B/C EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONHT-CL-YRPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSMT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 07/22/2223N4E24P.034339W26226RNTNWA011100 OAKESDALE AVE SWRENTON, WA 9805729FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400EMAIL: jeremiah.scherer@lumen.comR NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 07/22/2223N4E24P.034339W26226RNTNWA011100 OAKESDALE AVE SWRENTON, WA 9805739FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400EMAIL: jeremiah.scherer@lumen.comR R/W R/W R /W R/W R/W R/W EOP EO P EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP T R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EO P EO P EO P 6'65'78'94' R/W R/W R/W R /W R /W R /W R /W 67'44'58'51'30'52'32'59'TALBOT ROAD S.S GRADY WAY 800PARCEL#9154600005710PARCEL#192305907700PARCEL#1923089096707PARCEL#1923059023PARCEL#9154600010POF LMN MH 207-1 LMN MH 207SPEEDLIMIT35 56'NOTE:POF: @ MANHOLE 207-1, SPLICE COUNT WITH LRE25,169-180 FROM [SE94] ONTO [A3M6S] FALLING TOMANHOLE 207. @ MANHOLE 207, SPLICE COUNT FROM[A3M6S] ONTO [A3G4E] FALLING TO MANHOLE 293.11'TT NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 07/22/2223N4E24P.034339W26226RNTNWA011100 OAKESDALE AVE SWRENTON, WA 9805749FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400EMAIL: jeremiah.scherer@lumen.comRT EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EO P EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R /W R/W R/ W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W SW 7th STREETSIDEWALKTALBOT ROAD S.SPEEDLIMIT25SMITHERS AVE S.7'NOTE:@ MANHOLE 293, SPLICE COUNTFROM [A3G4E] ONTO [A3M6T]FALLING TO MANHOLE 227.LMN MH 293 425PARCEL#1923059025 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 07/22/2223N4E24P.034339W26226RNTNWA011100 OAKESDALE AVE SWRENTON, WA 9805759FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400EMAIL: jeremiah.scherer@lumen.comR EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP E O P E O P E O P E O P EOP EOP EOP EO P E O P EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP RA I N I E R A V E S . 6' S I D E W A L K R/W R/W R/W R/ W R/W R/ W R/ W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R /W R/W TLMN MH 227 28'6'11'30'43'98'41'CAR PRO201PARCEL#1923059031SW 7th STREET5' SIDEWALK5' SIDEWALKNOTE:@ MANHOLE 227, SPLICE COUNTFROM [A3M6T] ONTO [A3LZX]FALLING TO MANHOLE 113.650PARCEL#1823059133SPEEDLIMIT3511'11'11'11' NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 07/22/2223N4E24P.034339W26226RNTNWA011100 OAKESDALE AVE SWRENTON, WA 9805769FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400EMAIL: jeremiah.scherer@lumen.comR EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/ W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R/W R/W R /W R/W R/W R/W R/W EOP EOP EOP 31'11'SPEEDLIMIT35T13'14'333PARCEL#1923059072225PARCEL#1923059109300PARCEL#1823059253NOTE:@ MANHOLE 113, SPLICE COUNTFROM [A3LZX] ONTO [UA68]FALLING TO MANHOLE 110.LMN MH 113 SW 7th STREETSIDEWALK6' SIDEWALK9' PLANTERPLANTER11'10'11'11'37'40'4' PLANTERDRIVEWAY DRIVEWAY DRIVEWAY DRIVEWAY NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 07/22/2223N4E24P.034339W26226RNTNWA011100 OAKESDALE AVE SWRENTON, WA 9805779FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400EMAIL: jeremiah.scherer@lumen.comRSPEEDLIMIT35NOTE:@ MANHOLE 110, SPLICE COUNTFROM [UA68] ONTO [A3LQ5]FALLING TO MANHOLE 665. EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R /W R/W R /W R/W R/W R/W R/W R /W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W LIND AVE SW 4' PLANTER TLMN MH 110 37'12'40'12'39'20' EOP EOP EOP EOP 720PARCEL#1923059060501PARCEL#1923059056DRIVEWAYSW 7th STREET5' SIDEWALK5' SIDEWALK9' PLANTER7' PLANTER12'12'12'39'440PARCEL#1823059252550PARCEL#18230592516' SIDEWALK 11'11'11'11' NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.MT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 07/22/2223N4E24P.034339W26226RNTNWA011100 OAKESDALE AVE SWRENTON, WA 9805789FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400EMAIL: jeremiah.scherer@lumen.comR EOP EOP EOP EOP EOP EOP EO P E O P E O P E O P E O P R/W R/W R/W R/W R/W R/W R/W R/W R /W R/ W R/W R /W R/ W R/W R/W R/ W EOP EOP EOP EOP EOP EOP E O P EO P E O P E O P R/W R/W R/W R/W R/W R/W R/W R/ W R/ W R /W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W C/L C/L C/L C/L C/L C/L C/L OAKESDALE AVE SW6' SIDEWALK6' PLANTERS W 7 t h S T R E E T 5' S I D E W A L K 5' S I D E W A L K T 0+00 LMN MH 66535'15'11'45'150'OAKESDALE CENTER600-606PARCEL#9188000143BLACK RIVERNOTE:@ MANHOLE 665, PLACE NEW 48 COUNTFIBER IN EXISTING CONDUIT THRUMANHOLE 669 & THEN TO MANHOLE 670.11'13'12'12'46'11'32'11'13'12'12'SPEEDLIMIT35800PARCEL#91880001454' P L A N T E R 4' P L A N T E RPARCEL#24230490986' SIDEWALK6' PLANTER18'T4+80 LMN MH 669SEE SHEET 9 NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSGEO CODE:WC CLLI:RNGE:SECT:TOWN:NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS. EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP C/L C/L C/L C/L C/L C/L C/L C/L C/L C/L R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP T37'16'40'13'12'12'12'16'32'10+40 LMN MH 670NOTE:@ MANHOLE 670, SPLICE COUNT FROMNEW 48 FOC ONTO [A2YK9] FALLING TOCUSTOMER'S BUILDING MPOP.1000NOTE:@ CUSTOMER MPOP, THIS WILLBE A 2nd UPLINK ON EXISTINGEQUIPMENT & TERMINATELRE25, 265-266 IN FDP.1100OAKESDALE AVE SWPARCEL#085022000OAKESDALE AVE SW6' SIDEWALK5' GRASS6' SIDEWALKPARCEL#242304909835' EOP R/W R/W R/W R/W 34'35SPEEDLIMITMT LTD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: rick.ferdinando@centurylink.comDRAFTED BY: MOUNTAIN LTD/SL 07/22/2223N4E24P.034339W26226RNTNWA011100 OAKESDALE AVE SWRENTON, WA 9805799FIBER ENGINEER: JEREMIAH SCHERERPHONE NO: (702) 576-3400EMAIL: jeremiah.scherer@lumen.comRSEE SHEET 8