HomeMy WebLinkAboutMFP23000558DEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP23000558
IVR Number: 23000558
Permit Information
Permit Name: P.075972
Address/Location:02/01/2023Application Date:0886700220Parcel Number: 1901 OAKESDALE AVE SW
Permit Type:02/23/2023Issue Date:Franchise
Permit Work Class:02/23/2024Expiration Date:Minor Utility
Job Number: P.075972Franchise Type:Telephone
Description: Lumen to access MH T 129, HH127, HHA3MB9, and MH126. This will not be a disturbance of surface.
Contacts
Name Address PhoneTypeBilling
Austin Sweeney
Century Link
23315 66th Ave S
Kent, WA 98032
C: (253) 766-7549ApplicantX
Austin Sweeney
Century Link
23315 66th Ave S
Kent, WA 98032
C: (253) 766-7549Contact
Kim Parker
QWest Corporation
931 14th St, Suite 1000A
Denver, CO 80202
B: (303) 992-0752Contact
Jesse Patjens
CenturyLink / Lumen
23315 66th Ave S
Kent, WA 98032
Contact
Michael Smith
North Sky Communications
21320 84th Ave S
Kent, WA 98032
C: (206) 305-5881Contractor
Business License Number: 36846Construction Contractor: NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 23315 66th Ave S
Kent, WA 98032
Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐Electronic Copy of the TCP Application
☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
Northsky Communications
Tawnya Longfellow
22517 88th ave S Kent/WA 98031
P.075972
1901 Oakesdale Ave SW
3/1/2023 4/1/2023
Lumen to access MH T-129, HH127, HHA3MB9, and MH126. This will not be a disturbance of
surface.
MFP23000558
7 AM 3 PM
Kip Braaten CED 2-23-2023
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
MFP23000558
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
Austin Sweeney
Austin Sweeney 2/1/2023
MFP23000558
SW 16TH ST
O
A
K
E
S
D
A
L
E
A
V
E
S
W DWYDWYDWYDWYDWYSPEEDLIMIT25
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60
UNIFORMEDPOLICE OFFICER
HH 127
SPEEDLIMIT35
LANESHIFTAHEAD
ROADWORKAHEAD
BE PREPAREDTO STOP
BE PREPAREDTO STOP
BE PREPAREDTO STOP
ROADWORKAHEAD
ROADWORKAHEAD
ROADWORKAHEAD350'
350'350'350'
350'
350'
350'
350'350'350'
350'
350'
350'
S
Comments:
THIS IS TO ACCESS HH 127
THIS IS A LANE SHIFT AND FLAGGING
UNIFORMED POLICE OFFICER WILL ASSIST AT LIGHTED INTERSECTION
SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA
DRIVEWAYS WILL REMAIN ACCESSIBLE AT WORK AREA
SHIFTING TAPER105'
SW 16TH ST @ OAKESDALE AVE SW
HH 127 ACCESS
LANE SHIFT
UNIFORMED POLICE OFFICER
TRAFFIC CONTROL PLAN
JOB # P.075972.C.45
PERMIT #
Date:1/13/2023 Author:JORGIA DURR Project:P.075972.C.45LUMEN:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by City, County, and/or WSDOT
NOT TO SCALE
Approved 1/13/2023Darlene DurrTCS # 011915Phone 253-737-5198darlene.durr@hotmail.com
_______________________Darlene Durr
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #011915, darlene.durr@hotmail.com
N
Legend
HANDHOLE
WORK TRUCK
POLICE OFFICER
Work Area
CONES
S SPOTTER
www.invarion.com
MFP23000558
O
A
K
E
S
D
A
L
E
A
V
E
S
W
DWYSPEEDLIMIT25
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60
SPEEDLIMIT35
ROADWORKAHEAD
BE PREPAREDTO STOP
ROADWORKAHEAD ROADWORKAHEAD
ROADWORKAHEAD
350'350'
350'
350'350'350'
Comments:
THIS IS TO ACCESS HH A3MB8
THIS IS A LANE SHIFT AND CENTER LANE CLOSURE
SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA
DRIVEWAYS WILL REMAIN ACCESSIBLE AT WORK AREA
SHIFTING TAPER125'
SW 16TH ST @ OAKESDALE AVE SW
HH A3MB9 ACCESS
LANE SHIFT
CENTER LANE CLOSURE
TRAFFIC CONTROL PLAN
JOB # P.075972.C.45
PERMIT #
Date:1/13/2023 Author:JORGIA DURR Project:P.075972.C.45LUMEN:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by City, County, and/or WSDOT
NOT TO SCALE
Approved 1/13/2023Darlene DurrTCS # 011915Phone 253-737-5198darlene.durr@hotmail.com
_______________________Darlene Durr
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLANIN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #011915, darlene.durr@hotmail.com
N
LANESHIFTAHEAD
S
HH A3MB9
WORK AREA
12' X 190.350'
CENTERLANECLOSEDAHEAD
Legend
HANDHOLE
WORK TRUCK
CONES
S SPOTTER
Work Area
www.invarion.com
MFP23000558
SW 16TH ST
O
A
K
E
S
D
A
L
E
A
V
E
S
W
DWYDWYDWYDWYDWYSPEEDLIMIT25
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60
SPEEDLIMIT35
ROADWORKAHEAD
BE PREPAREDTO STOP
ROADWORKAHEAD ROADWORKAHEAD
ROADWORKAHEAD
350'350'350'
350'
350'350'
350'
Comments:
THIS IS TO ACCESS MH 126
THIS IS A LANE SHIFT AND CENTER LANE CLOSURE
SPOTTER WILL ASSIST PEDESTRIANS AT WORK AREA
DRIVEWAYS WILL REMAIN ACCESSIBLE AT WORK AREA
SHIFTING TAPER125'
SW 16TH ST @ OAKESDALE AVE SW
MH 126 ACCESS
LANE SHIFT
CENTER LANE CLOSURE
TRAFFIC CONTROL PLAN
JOB # P.075972.C.45
PERMIT #
Date:1/14/2023 Author:JORGIA DURR Project:P.075972.C.45LUMEN:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be determined by City, County, and/or WSDOT
NOT TO SCALE
Approved 1/14/2023Darlene DurrTCS # 011915Phone 253-737-5198darlene.durr@hotmail.com
_______________________Darlene Durr
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TOALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:DARLENE DURR, TCS #011915, darlene.durr@hotmail.com
N
LANESHIFTAHEAD
CENTERLANECLOSEDAHEAD
MH 126
WORK AREA
12' X 170'
S
Legend
MANHOLE
CONES
Work Area
WORK TRUCK
S SPOTTER
www.invarion.com
MFP23000558
SW 16TH ST
RAYMOND AVE SWRAYMOND AVE SWSENECA AVE SWTRAFFIC CONTROL PLAN
JOB # P.075972.C.45
PERMIT #
Date:1/14/2023 Author:JORGIA DURR Project:P.075972.C.45LUMEN:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and City of RENTON requirements.
2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.
6. Work hours will be determined by City, County, and/or WSDOT
Legend
MANHOLE
CONES
WORK TRUCK
Work Area
NOT TO SCALE
Approved 1/14/2023
Darlene Durr
TCS # 011915
Phone 253-737-5198
darlene.durr@hotmail.com
_______________________Darlene Durr
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:DARLENE DURR, TCS #011915, darlene.durr@hotmail.com
NSPEEDLIMIT
30
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
SPEEDLIMIT
35
SHIFTING TAPER105'
MH T-129
WORK AREA
10' X 170'
LANESHIFTAHEAD
ROADWORKAHEAD
CENTERLANECLOSEDAHEAD
ROADWORKAHEAD
ROADWORKAHEAD
ROADWORKAHEAD
ROADWORKAHEAD
350'350'
350'
350'
350'350'
350'
350'
Comments:
THIS IS TO ACCESS MH T-129
THIS IS A LANE SHIFT AND CENTER LANE CLOSURE
PEDESTRIANS NOT AFFECTED
DRIVEWAYS WILL REMAIN ACCESSIBLE AT WORK AREA
SW 16TH ST @ RAYMOND AVE SW
MH T-129 ACCESS
LANE SHIFT
CENTER LANE CLOSURE
www.invarion.com
MFP23000558
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE: WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.10500000000”NVICINITY MAPSL1901 OAKESDALE AVE SWRENTON, WA 98057P.075972W26226RNTNWA0123N5E512/26/2261®CUSTOMER NAME: SEATTLE SOCCER LLCLCON: TOM ROSEPHONE #: 206-300-0610EMAIL: trose@voiante.comWFMT #: W.2953353ORDER #: N29509957ARMOR OR DSR #: 1103-2267778SCOPE OF WORK:POF: @ MANHOLE T-129, PUSH LRE14, 9-10 FROM EXISTING FIBER CABLE [A2VG5] TO EXISTING FIBER CABLE [TP54] FALLING TO HANDHOLE 127.@ HANDHOLE 127, SPLICE FIBER CABLE [TP54] TO NEW FIBER CABLE BEING PLACED APPROX 1050' THRU EXISTING CONDUIT INTO HANDHOLE A3MB9(LEAVE 50' LOOP IN HH A3MB9) THEN TO MANHOLE 126. @ MANHOLE 126, SPLICE NEW FIBER CABLE TO CABLE [A3MBN] BEING PLACED ON P.044022TO CUSTOMER'S MPOP. @ CUSTOMER'S MPOP, PLACE NEW EQUIPMENT & FDP. P.044022 SHOULD BE PLACING ENTRANCE. VENDOR COMPLETES BE.SH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: LEANN MILLERPHONE NO: 720-607-5687EMAIL: leann.miller@lumen.comMFP23000558
TT
TTTEE
EEE CATV CATV CATV
CA
TV CATV CATV
CATV
CATV
GG
GGG TS TS TS
TS
TS
WWWWW S S
S S
S
SD SD SD
SD
SD
C/L C/L
C/
L C/L
C/L
C/
L
R/W R/W R/W
R/W
R/W
R/W
R/W P/L P/L P/L
P/L
P/L
P/L
B/C B/C B/C
B/C
B/C
B/C
B/C
B/
C EOP EOP
EOP
EOP
EOP
TTTUSAMEEPWREE CAT
V
CATV
TVTV CATV
CATV
CATV
CATV CATV
CATV
CATV
CATV VTS C/L
C/L VWSSDVETTTXXX'XXX'XXX'XXX'X IRRIG IRRIG F1TTTTTTNOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB: RNGE:SECT:TOWN:GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:JOB:GEO CODE:WC CLLI:DRAFTED BY: MOUNTAIN LTD/SH OF SL1901 OAKESDALE AVE SWRENTON, WA 98057P.075972W26226RNTNWA0123N5E512/26/2262®MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: PAULA ELSAEEDPHONE NO: 253-458-6583EMAIL: paula.elsaeed@lumen.comMFP23000558
NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS. EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP SEE SHEET 4SEE SHEET 3
T800PARCEL#3340406430801PARCEL#3340405300SW 16th STREETSIDEWALKSIDEWALKPOF LMN MH T-1298'13'13'13'38'22'NOTE:POF: @ MANHOLE T-129, PUSH LRE14, 9-10 FROMEXISTING FIBER CABLE [A2VG5] TO EXISTING FIBERCABLE [TP54] FALLING TO HANDHOLE 127.NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB: GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSSL1901 OAKESDALE AVE SWRENTON, WA 98057P.075972W26226RNTNWA0123N5E512/26/2263RSH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: PAULA ELSAEEDPHONE NO: 253-458-6583EMAIL: paula.elsaeed@lumen.comMFP23000558
NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS. EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP R/W EOP EOP EOP 35SPEEDLIMITSEE SHEET 5
SEE SHEET 3T10'35'26'136' R/W R/W R/W 51'32' R/W R/W R/W R/W R/W 33' R/W R/W R/W R/W R/W R/W R/W PARCEL#33404062551120PARCEL#3340406120900PARCEL#33404062601101PARCEL#3340405300PARCEL#2423049136OAKESDALE AVE SWSIDEWALKSIDEWALK
SW 16th STREETSIDEWALKSIDEWALK0+00 LMN H
H
1
2
7
13'13'13'34'26'11'11'11'11'11'11'11'11'11'11'11'11'11'NOTE:@ HANDHOLE 127, SPLICE FIBER CABLE[TP54] TO NEW FIBER CABLE BEING PLACEDAPPROX 1050' THRU EXISTING CONDUIT INTOHANDHOLE A3MB9 THEN TO MANHOLE 126.NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB: GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS4RSL1901 OAKESDALE AVE SWRENTON, WA 98057P.075972W26226RNTNWA0123N5E512/26/226SH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: PAULA ELSAEEDPHONE NO: 253-458-6583EMAIL: paula.elsaeed@lumen.comMFP23000558
NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.164'5' R/W EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP EOP EOP EOP R/W R/W R/W T EOP EOP EOP EOP EOP EOP EOP EOP 35SPEEDLIMITT5'SEE SHEET 4 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 54'26'1300PARCEL#24230490481301PARCEL#2423049022SW 16th STREETSIDEWALKSIDEWALK11'11'11'8+00 LMN HH A3MB9PLACED ON P.04402210+50 LMN MH 126
NOTE:@ HANDHOLE A3MB9 (LEAVE 50' LOOPIN HH A3MB9) THEN CONTINUE TOPLACED APPROX 1050' THRU EXISTINGCONDUIT INTO MANHOLE 126.NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB: GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS5RSL1901 OAKESDALE AVE SWRENTON, WA 98057P.075972W26226RNTNWA0123N5E512/26/226SH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: PAULA ELSAEEDPHONE NO: 253-458-6583EMAIL: paula.elsaeed@lumen.comMFP23000558
35SPEEDLIMIT EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W EOP 12'1901OAKESDALE AVEPARCEL#0886700220OAKESDALE AVE SW
SIDEWALK
SIDEWALKNOTE:@ CUSTOMER'S MPOP, PLACE NEWEQUIPMENT & FDP. P.044022 SHOULD BEPLACING ENTRANCE. VENDOR COMPLETES BE.NOTE:FOR UNDERGROUND ACTIVITY: TEST AND VENTILATEMANHOLE/UTILITY VAULT PRIOR TO ENTRY, PLACEWARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED, AND USE EYE AND HEAD SAFETY PROTECTIONPER FEDERAL, STATE, AND LOCAL REGULATIONS.11'12'11'11'NOTICE-NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB: GEO CODE: WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYS6RSL1901 OAKESDALE AVE SWRENTON, WA 98057P.075972W26226RNTNWA0123N5E512/26/226SH OF DRAFTED BY: MOUNTAIN LTD/MT LTD ENGINEER: RICK FERDINANDOPHONE NO: 206-276-3165EMAIL: rick.ferdinando@lumen.comFIBER ENGINEER: PAULA ELSAEEDPHONE NO: 253-458-6583EMAIL: paula.elsaeed@lumen.comMFP23000558