HomeMy WebLinkAboutAllura At Tiffany Park #61517 5-30-1805/30/2018
CalPortland
APELAND CONTRACTING INC
ALLURA AT TIFFANY PARK
The enclosed concrete mix designs are being submitted for use on the above project. All mix designs are designed
based on specification information provided. These mix designs will be produced in conformance with applicable
codes and specification and shall be tested in accordance with ASTM, AASHTO, ODOT and/or WSDOT procedures.
ASTM C94 Section 4.6 states “…The purchaser shall ensure that the manufacturer is provided copies of all reports
of tests performed on concrete samples…Reports shall be provided on a timely basis.” In accordance with the
specification, approval of these mix designs carries with it CalPortland’s inclusion on the distribution list for all
concrete test reports.
ACI 301 16.7.4.3 states “to facilitate testing and inspection, the contractor shall provide and maintain for the sole
use of the testing agency adequate facilities for safe storage and proper curing of concrete test specimens on the
project site for the first 24 hours as required by ASTM C31.” CalPortland does not guarantee field cured cylinders.
Proper curing for early strength is the responsibility of the contractor.
The cement used on this project will conform to ASTM C150, AASHTO M85, and are approved per ODOT and/or
WSDOT Standard Specifications.
Pozzolanic materials used on this project will conform to ASTM C618, AASHTO M295, and are approved per ODOT
and/or WSDOT Standard Specifications.
Ground Granulated Blast Furnace Slag used on this project will conform to ASTM C989, AASHTO M302, and are
approved per ODOT and/or WSDOT Standard Specifications.
Aggregates used on this project will conform to ASTM C33 and are approved per ODOT and/or WSDOT Standard
Specifications.
Air-entrainment used on this project will conform to ASTM C260 and are approved per ODOT and/or WSDOT
Standard Specifications.
All other chemical admixtures used on this project will conform to ASTM C494 and are approved per ODOT and/or
WSDOT Standard Specifications.
When ordering concrete, it is the customer’s responsibility to order the approved mix number for the project and
application. When ice, hot water, accelerator, retarder, or high-range water reducer is needed to meet project
specifications, it is the contractor’s responsibility and cost to order the proper materials.
CalPortland mix designs (strength, slump, air, and unit weight) are based on testing at the truck discharge per
ASTM standards. CalPortland will not be responsible for these plastic and hardened qualities due to pumping or
other methods of conveying.
If you have any questions please contact, Kasey MacWatters at in our Technical Services Department.
This submittal contains proprietary, confidential, and legally privileged information. Disclosure, copying, and distribution
without express written permission are strictly prohibited.
05/30/2018
To:APELAND CONTRACTING INC
RE:ALLURA AT TIFFANY PARK
Thank you for the opportunity to provide materials for this project. The mixes chosen for this submittal
were based on the documents provided by and conversations had with the requesting party.
The mixes below have been included with this submittal for your review:
AirUseSlump W/CMMix
Footings 6" (+/- 1.5")0.361517
7.0SK 3/4 SLAG AEA WRA ADVA
5% (+/- 1.5%)
Concrete mix designs are submitted to meet project specifications. Acceptable material performance is
based on proper testing and protection of concrete and concrete samples. Concrete mix design
ingredients may be adjusted to maintain yield, consistency and performance. Similar materials, with
proven performance, may be substituted at the supplier’s discretion. Concrete will be batched in
accordance with the applicable portions of the ASTM C94 standards unless otherwise agreed upon.
Additional Project Submittal Information:
Sincerely,
Kasey MacWatters
Kmacwatters@calportland.com
This submittal contains proprietary, confidential, and legally privileged information. Disclosure, copying, and distribution
without express written permission are strictly prohibited.
Absorption
Mix ID 61517
Submittal Information
Material Description Supplier Mass SSDlb Volumeft3SpecificGravity
Mix Name 7.0SK 3/4 SLAG AEA WRA ADVA
Compressive Strength (f'c)6000 psi @ 28 Days
Group
W/CM Ratio 0.3
Slump 6" (+/- 1.5")
Customer
Project Name
Mix Information
Mix Properties
Sack Content 8.41
Total Water 28.77
Water/Sack 3.42
Total Mass 4046.0
Unit Weight 149.30
Total Volume 27.10gal
gal
lb
lb/ft3
ft3
Use
Air 5% (+/- 1.5%)
94 lb/sack
Flexural Strength (f's)
Submittal Name
Contract ID
Project Location
3.15 3.358Cement660
Lafarge N.A.2.89 0.726Additive131
Manke Resources 2.69 7.509Aggregate12601.6
Manke Resources 2.74 10.23517501.22
1 3.846Water240
W.R. GRACE 1.35 0.00826Admixture0.696
W.R. GRACE 1 0.028911.804
W.R. GRACE 1 0.033042.062
W.R. GRACE 1 0.006
Portland Cement
Slag
SLAG - GGBSF-SLAG CEMENT
Fine Aggregate
MAN_SAND - BUILDING SAND
Coarse Aggregate
MAN_3/4 - AASHTO #57
Potable Water
WATER - WATER
Air Entrainer
AEA - AIR ENTRAINMENT-WR GRACE
Range: 0.5-150 fl oz/100 lb CM
Water Reducer
WRA - WRDA64-WR GRACE
Range: 0.5-4.5 fl oz/100 lb CM
Water Reducer High Range
ADVA - ADVA 195 WR GRACE
Range: 0.5-25 fl oz/100 lb CM
Viscosity Modifier
VMAR - VMAR 3 WR GRACE
Range: 0-35 oz/yd3
Air 1.355Air
Concrete Mix Submittal
Duwamish 282/291
CITY OF SEATTLE
Department of Construction and Inspections
CONTINUOUS APPROVAL STATUS
6,000 psi at 28 days
batch plant inspection is not required
Continuous Approval good until 5/1/2019
approved subject to errors and omissions
Authorized by SDCI
Slump shall not exceed 7.5" at
the end of the
truck chute
NOTE: Supplier shall provide a copy of this mix design to
the contractor. Contractor shall provide a copy of this
mix design to the special inspector prior to each use.
Approval of the engineer of record is required prior to job use.
Concrete Mix Submittal
Duwamish 282
Gradation
Sieve % Passing Specification
1 1/2" (37.5mm)100.0
1" (25mm)98.8
3/4" (19mm)88.5
1/2" (12.5mm)67.7
3/8" (9.5mm)57.9
#4 (4.75mm)44.6
#8 (2.36mm)40.1
#16 (1.18mm)29.4
#30 (0.6mm)17.2
#50 (0.3mm)5.2
#100 (0.15mm)1.1
#200 (75µm)0.36
Contact Kasey MacWatters
Kmacwatters@calportland.comEmail
ACI 318 Required Average Strength
Temp(Concrete)
(°F)
Slump
(in)
Acceptance
Strength(28-Day)
(psi)
Moving
Average
(psi)
Air
Content
(%)Test Date Mix Laboratory
Design Strength (f'c)6000 psi @ 28 Days
8140 psi @ 28 DaysRequired Strength (f'cr)
Number Of Tests
Average Strength
29
8936 psi
St Dev 1166 psi
Mix ID 61517
Mix Name 7.0SK 3/4 SLAG AEA WRA
ADVA
Comp
Strength(3-Day)
(psi)
Comp
Strength(7-Day)
(psi)
60 6.561517 958012/01/2016 7190
6.561517 846012/20/2016 Seattle 5500
64 7 5 9407615171018012/27/2016 Otto Rosenau &
Associates
7760
60 7.5 943361517966012/27/2016 Seattle 7070
63 7.75 4.9 10090615171043001/10/2017 85405500
66 7.75 4.8 996361517980002/17/2017 Seattle 75205030
1003761517988003/16/2017 Seattle 7890
70 7 3.5 976361517961003/16/2017 Seattle 7500
71 8 4.5 9847615171005003/16/2017 Seattle 7680
58 5.25 961061517917006/02/2017 A.A.R. Testing 6830
77 5 3.7 857361517650006/07/2017 O'Neill Service
Group
5500
60 5 5.2 809761517862006/14/2017 Mayes Testing
Engineers
6890
64 4.5 4.8 730061517678006/14/2017 Seattle 4460
65 5 5.2 813361517900006/14/2017 Seattle 7020
64 5.75 5.4 764061517714006/15/2017 Mayes Testing
Engineers
5650
70 6.5 840061517906007/03/2017 Krazan &
Associates
6880
67 6 869061517987007/03/2017 Krazan &
Associates
8010
67 5.75 957761517980007/03/2017 Krazan &
Associates
7590
7 4.5 9987615171029007/03/2017 Seattle 8070
65 6.5 4.6 944761517825007/11/2017 Seattle 7580
81 6 5.5 943361517976008/18/2017 Seattle 7730
67 6 4.1 849761517748011/27/2017 Krazan &
Associates
60303810
70 6.25 4.4 815361517722011/27/2017 Krazan &
Associates
52603580
71 8 8347615171034012/27/2017 Krazan &
Associates
7730
66 7 6.5 876061517872002/01/2018 6860
63 7.5 929361517882002/26/2018 Otto Rosenau &
Associates
6870
62 7.5 901361517950002/26/2018 Otto Rosenau &
Associates
7300
61 6.25 870761517780002/26/2018 Otto Rosenau &
Associates
6150
67 7 5 822061517736004/03/2018 6600
Concrete Mix Evaluation Report
Manufacturer's Certification
We hereby certify that CalPortland Type I/II Low Alkali Cement meets the standard requirements of ASTM C150 and AASHTO M85
specification for Type I and Type II cements. Additionally, CalPortland Type I/II Low Alkali Cement meets the optional requirement
for low alkali (less than or equal to 0.60 total alkali). Reported are the average chemical and physical data for the lot..
18-120 Report Date: 5/14/2018
Chemical Properties
ASTM C150 and AASHTO M85 Requirements Analysis
Results
Silicon dioxide (SiO2), %
Ferric oxide (Fe2O3), max, %
Aluminum oxide (Al2O3), max, %
Calcium oxide (CaO), %
Insoluble residue (IR), max, %
Alkalies (Na2O+0.658*K2O), max, %
Tricalcium silicate (C3S), %
Dicalcium silicate (C2S), %
Tricalcium aluminate (C3A), max, %
Physical Properties
Air content of mortar, max, volume %
Blaine Fineness, min, m²/kg
Autoclave expansion, max, %
Compressive Strength, min
3 Day, MPa
3 Day, psi
7 Day, MPa
7 Day, psi
20.2
3.9
3.8
65.0
0.7
2.6
2.7
0.3
0.54
64
10
4
10
385
-0.01
28.9
4190
34.6
5020
Apparatus and methods used in this laboratory have been checked by the Cement and Concrete Reference Laboratory of the National
Institute of Standards and Technology. A copy of the report detailing their findings is available upon request. Major oxides are
analyzed in accordance with ASTM C114.
Kevin Wolf - Director of Technical Services
---
6.0
6.0
---
6.0
3.0
3.5
1.5
0.60
---
---
8
12
260
0.80
10.0
1450
17.0
2470
Nanjing, China
Lot #:
Source:
Type I / II Low Alkali Cement
Limestone
Analysis
Cement
Base
2.4
1.0
0.2
Tetracalcium aluminoferrite (C4AF), %---11
67
10
4
C4AF + 2(C3A), max, %---19
50.6
0.2
0.1
CO2, %---1.9
Limestone addition, max, %5.0 4.8
CaCO3 in Limestone, min, %
28 Day (from previous lot), MPa ---40.5
28 Day (from previous lot), psi ---5870
Vicat Setting Time, min-max, minutes 45 - 375 130
Magnesium oxide (MgO), max, %
Sulfur trioxide (SO3), max, %
Loss on ignition (LOI), max, %
Type IIType I
---
---
---
3.0
3.5
1.5
0.60
---
---
---
5.0
260
19.0
---
45 - 375
12.0
---
6.0
---
---
---
70
12
12
0.80
2760
---
1740
70 90
1 Day, psi ------2430
Ship Point: Seattle Cement Terminal
CalPortland Company 1050 N. River Street Portland, OR 97227-1719
www.calportland.com Customer Service 503-535-7713
Cement Test ReportCement Test Report
Mill Test Report Number:SEA_NEWCEM_MAY18
YEAR:2018
MONTH:April
PLANT:Seattle
CEMENT TYPE:NewCem Grade 100
Fineness by Air Permeability 445 Fineness by Air Permeability 629
(m2/kg; ASTM C204)(m2/kg; ASTM C204)
Fineness by 45 µm (No. 325) Sieve 2.9 Fineness by 45 µm (No. 325) Sieve 3.8
(% retain; ASTM C430)(% retain; ASTM C430)
Compressive Strength
(ASTM C109/C109 M)psi Compressive Strength SAI Limit
Reference Cement Slag
Compressive Strength
(ASTM C109/C109 M)psi Compressive Strength SAI Limit
7-day 5,290 (ASTM C109/C109 M)psi [Mpa]SAI Min
28-day 6,170 7-day 4520 [31.2] 86 75
28-day Previous Month 6300 [43.4] 102 95
Actual Max Limit
Total Alkalies (Na2O + 0.658 K2O)0.89 0.9 Specific Gravity 2.87
(%, ASTM C114)(Mg/m3; ASTM C188)
Actual Max LimitActual
Slag Air Content of Mortar 4.8
CHEMICAL ANALYSIS Percent (%, ASTM C185)
Silica Dioxide (SiO2; ASTM C114)31.8
Ferric Oxide (Fe2O3; ASTM C114)1.1 Sulfide Sulfur 0.66
Aluminum Oxide (Al2O3; ASTM C114)13.2 (% S, ASTM C114)
Calcium Oxide (CaO; ASTM C114) 43.05
Sulfur Trioxide (SO3; ASTM C114)3.7 Sulfate Ion 2.1
Magnesium Oxide (MgO; ASTM C114) 4.7 (% as SO3, ASTM C114)
2.5
4
Max Limit
12
Magnesium Oxide (MgO; ASTM C114)4.7 (% as SO3, ASTM C114)
Potassium Oxide (K2O; ASTM C114)0.5
Titanium Oxide (TiO2, ASTM C114)0.7 Autoclave expansion -0.010
Loss on Ignition (L.O.I.; ASTM C114) 2.1 (%, CSA A3004-B5)
Inorganic Process Addition 7
Slag source is JFE Mineral Company in Kurashiki City, Japan. NewCem is ground and manufactured in Seattle, WA.
Certified by:
The ground granulated blast furnace slag complies with the current specification of the chemical physical requirement of ASTM C-989, AASHTO
M-302 for grade 100 Ground Granulated Blast Furace Slag (GGBFS) and and CSA A3001 Slag.
0.5
Certified by:
Daniel Waldron
Quality Control Laboratory Supervisor
May 15, 2018
GCP Applied Technologies Inc
62 Whittemore Avenue
Cambridge, MA 02140-1692
T 617-876-1400
gcpat.com/construction
Date: 2/17/2017
Tamson Omps
CalPortland
5975 East Marginal Way South
Seattle, WASHINGTON 98134
Project Name: Washington
Product Selected: ADVA® 195
This is to certify that ADVA 195, a High Range Water Reducer, as manufactured
and supplied by Construction Products, GCP Applied Technologies Inc., is
formulated to comply with the Specifications for Chemical Admixtures for Concrete,
ASTM: C494, Type A, F, AASHTO: M194, Type A, F.
ADVA 195 does not contain calcium chloride or chloride containing compounds as
a functional ingredient. Chloride ions may be present in trace amounts contributed
from the process water used in manufacturing.
G. Terry Harris
Manager of Technical Services, North America Concrete
GCP Applied Technologies Inc
62 Whittemore Avenue
Cambridge, MA 02140-1692
T 617-876-1400
gcpat.com/construction
Date: 2/16/2017
Tamson Omps
CalPortland
5975 East Marginal Way South
Seattle, WASHINGTON 98134
Project Name: Washington
Product Selected: Daravair® 1000
This is to certify that Daravair 1000, a Air Entraining Agent, as manufactured and
supplied by Construction Products, GCP Applied Technologies Inc., is formulated
to comply with the Specifications for Chemical Admixtures for Concrete, ASTM:
C260, AASHTO: M154.
Daravair 1000 does not contain calcium chloride or chloride containing
compounds as a functional ingredient. Chloride ions may be present in trace
amounts contributed from the process water used in manufacturing.
G. Terry Harris
Manager of Technical Services, North America Concrete
GCP Applied Technologies Inc.
62 Whittemore Avenue
Cambridge, MA 02140-1692
T 617-876-1400
gcpat.com/construction
Date: 3/12/2018
Kasey Macwatters
Calportland
5975 E Marginal Way S
Seattle WA, WASHINGTON 98134
Project Name: Washington
Product Selected: V-MAR® 3
This is to certify that V-MAR 3, a Viscosity Modifier, as manufactured and
supplied by GCP Applied Technologies Inc., is formulated to comply with the
Specifications for Chemical Admixtures for Concrete, ASTM: C494, Type S,
AASHTO: M194, Type S.
V-MAR 3 does not contain calcium chloride or chloride containing compounds as a
functional ingredient. Chloride ions may be present in trace amounts contributed
from the process water used in manufacturing.
Robert J. Hoopes
Product Development Engineer
GCP Applied Technologies Inc
62 Whittemore Avenue
Cambridge, MA 02140-1692
T 617-876-1400
gcpat.com/construction
Date: 2/17/2017
Tamson Omps
CalPortland
5975 East Marginal Way South
Seattle, WASHINGTON 98134
Project Name: Washington
Product Selected: WRDA® 64
This is to certify that WRDA 64, a Water Reducer, as manufactured and supplied
by Construction Products, GCP Applied Technologies Inc., is formulated to comply
with the Specifications for Chemical Admixtures for Concrete, ASTM: C494, Type
A, D, AASHTO: M194, Type A, D.
WRDA 64 does not contain calcium chloride or chloride containing compounds as
a functional ingredient. Chloride ions may be present in trace amounts contributed
from the process water used in manufacturing.
G. Terry Harris
Manager of Technical Services, North America Concrete