HomeMy WebLinkAboutF_ConcreteMixDesign_Footings_180316AirUseSlump W/CMMix Footings 8" (+/- 1.5")0.2860885 7.75SK 3/4" SLAG WRA ADVA 1.5 Absorption Mix ID 60885 Aggregate Nominal Size 1" (25mm) Submittal Information Material Description Supplier Mass SSD lb Volume ft3 Specific Gravity Mix Name 7.75SK 3/4" SLAG WRA ADVA Compressive Strength (f'c)4500 psi @ 28 Days Group Air Entrained W/CM Ratio 0.28 Slump 8" (+/- 1.5") Customer APELAND CONTRACTING INC Project Name ALLURA AT TIFFANY PARK Mix Information Mix Properties Sack Content 9.34 Total Water 29.97 Water/Sack 3.21 Total Mass 4196.4 Unit Weight 154.85 Total Volume 27.10gal gal lb lb/ft3 ft3 Use Footings Air 1.5 94 lb/sack Flexural Strength (f's) Submittal Name Allura At Tiffany Park Contract ID Project Location Portland Type I/II Type I-II Cement Nanjing 3.15 3.704Cement728 Slag GGBSF-SLAG CEMENT Lafarge N.A.2.89 0.832Additive150 Fine Aggregate BUILDING SAND Manke Resources 2.69 7.577Aggregate12721.6 Coarse Aggregate AASHTO #57 Manke Resources 2.74 10.46917901.22 Potable Water WATER 1 4.006Water250 Water Reducer WRDA64-WR GRACE Range: 0.5-5 fl oz/100 lb CM W.R. GRACE 1 0.03210Admixture2.003 Water Reducer High Range ADVA 195 WR GRACE Range: 0.5-25 fl oz/100 lb CM W.R. GRACE 1 0.073354.577 Viscosity Modifier VMAR 3 WR GRACE Range: 0-35 oz/yd3 W.R. GRACE 1 0.006 Air 0.406Air Gradation Sieve % Passing Specification 1 1/2" (37.5mm)100.0 1" (25mm)98.8 3/4" (19mm)88.4 1/2" (12.5mm)67.5 3/8" (9.5mm)57.7 #4 (4.75mm)44.4 #8 (2.36mm)39.8 #16 (1.18mm)29.1 #30 (0.6mm)17.1 #50 (0.3mm)5.2 #100 (0.15mm)1.1 #200 (75µm)0.35 Concrete Mix Submittal Duwamish 282 ACI 318 Required Average Strength Acceptance Strength (28-Day) (psi) Moving Average (psi)Test Date Mix Design Strength (f'c)4500 psi @ 28 Days 5700 psi @ 28 DaysRequired Strength (f'cr) Number Of Tests Average Strength 1 11150 psi St Dev psi Mix ID 60885 Mix Name 7.75SK 3/4" SLAG WRA ADVA Comp Strength (7-Day) (psi) 60885 1115001/18/2018 8880 Concrete Mix Evaluation Report Manufacturer's Certification We hereby certify that CalPortland Type I/II Low Alkali Cement meets the standard requirements of ASTM C150 and AASHTO M85 specification for Type I and Type II cements. Additionally, CalPortland Type I/II Low Alkali Cement meets the optional requirement for low alkali (less than or equal to 0.60 total alkali). Reported are the average chemical and physical data for the lot.. 18-042 Report Date: 3/5/2018 Chemical Properties ASTM C150 and AASHTO M85 Requirements Analysis Results Silicon dioxide (SiO2), % Ferric oxide (Fe2O3), max, % Aluminum oxide (Al2O3), max, % Calcium oxide (CaO), % Insoluble residue (IR), max, % Alkalies (Na2O+0.658*K2O), max, % Tricalcium silicate (C3S), % Dicalcium silicate (C2S), % Tricalcium aluminate (C3A), max, % Physical Properties Air content of mortar, max, volume % Blaine Fineness, min, m²/kg Autoclave expansion, max, % Compressive Strength, min 3 Day, MPa 3 Day, psi 7 Day, MPa 7 Day, psi 20.2 4.2 3.8 64.6 0.8 2.7 2.6 0.5 0.56 61 11 5 10 377 -0.02 27.0 3910 32.3 4680 Apparatus and methods used in this laboratory have been checked by the Cement and Concrete Reference Laboratory of the National Institute of Standards and Technology. A copy of the report detailing their findings is available upon request. Major oxides are analyzed in accordance with ASTM C114. Kevin Wolf - Director of Technical Services --- 6.0 6.0 --- 6.0 3.0 3.5 1.5 0.60 --- --- 8 12 260 0.80 10.0 1450 17.0 2470 Nanjing, China Lot #: Source: Type I / II Low Alkali Cement Limestone Analysis Cement Base 2.0 0.9 0.2 Tetracalcium aluminoferrite (C4AF), %---11 64 12 5 C4AF + 2(C3A), max, %---21 51.5 0.3 0.1 CO2, %---1.5 Limestone addition, max, %5.0 3.7 CaCO3 in Limestone, min, % 28 Day, MPa ---41.1 28 Day, psi ---5960 Vicat Setting Time, min-max, minutes 45 - 375 125 Magnesium oxide (MgO), max, % Sulfur trioxide (SO3), max, % Loss on ignition (LOI), max, % Type IIType I --- --- --- 3.0 3.5 1.5 0.60 --- --- --- 5.0 260 19.0 --- 45 - 375 12.0 --- 6.0 --- --- --- 70 12 12 0.80 2760 --- 1740 70 92 1 Day, psi ------2340 Ship Point: Seattle Cement Terminal CalPortland Company 1050 N. River Street Portland, OR 97227-1719 www.calportland.com Customer Service 503-535-7713 Plant:Richmond, British Columbia Product: Portland Cement Type IL(15) Mill Test Report # R-TIL-18-02 Manufactured: Item Spec limit Test Result Item Spec limit Rapid Method, X-Ray (C 114) Air content of mortar (%) (C 185) 12 max 4.3 SiO2 (%)---18.1 Al2O3 (%)---4.4 Blaine Fineness (m2/kg) (C 204) --- 459 Fe2O3 (%)---3.2 CaO (%) ---63.1 Passing 325 (%) (C 430) --- 99.3 MgO (%)---0.8 SO3 (%)3.0 max*2.8 Autoclave expansion (%) (C 151) [-0.2 - 0.8] 0.03 Loss on ignition @ 950 (%)10.0 max 6.5 NaEq (Alkali) (%)---0.45 Compressive strength (Mpa [PSI]) (C 109) Insoluble residue (%)---0.24 Mpa PSI 3 days 13.0 [1890] min 31.1 4510 7 days 20.0 [2900] min 36.7 5320 28 days (Reflects previous month's data)25.0 [3620] min 43.8 6350 Time of setting (minutes) Adjusted Potential Phase Composition*** Vicat Initial (C 191) 45-420 92 C3S (%)---47 C2S (%)---17 C3A (%)---6 C4AF (%)---10 Sulphate Resistance C1012 (Q1/2017) 0.092 * May exceed 3.0% SO3 maximum based on our C 1038 results of <0.02% expansion at 14 days. *** Corrected by using ASTM Calculation for Limestone Cement We certify that the above described cement, at the time of shipment, meets the chemical and physical requirements of: ASTM C 595-17 & AASHTO M 240-16 STANDARD SPECIFICATIONS FOR TYPE IL(15) CEMENT Cement complies with NSF 61 Certified By: Questions or enquiries can be directed to Rob Shogren Western BU - Richmond Rob Shogren, PhD 7611 No 9 Rd Richmond, BC Lafarge - Technical Director 604 244 4300 5400 W Marginal Way SW, Seattle WA Harold Ptachyk B.Sc., PChem P +1 206 923 9953 Quality Manager E Rob.Shogren@lafargeholcim.com 2/9/2018 JANUARY 2018 ASTM C595 Standard Requirements CHEMICAL ANALYSIS PHYSICAL ANALYSIS Cement Mill Test Report Month of Issue: FEBRUARY 2018 Test Result