SITE SPECIFIC DATA
PROJECT NUMBER
15274
PROJECT NAME
600 SW LOTH PARKING LOT
PROJECT LOCATION
RENTON,
WA
STRUCTURE ID
N/A
TREATMENT REQUIRED
VOLUME BASED (CF)
FLOW BASED (CFS)
N/A
0.25
PEAK BYPASS REQUIRED (CFS) -
IF APPLICABLE
1.17
PIPE DATA
LE.
MATERIAL
DIAMETER
INLET PIPE 1
14.70
PVC
12"
OUTLET PIPE
13.41
PVC
12"
PRETREATMENT
BIORLTR4TION
DISCHARGE
RIM ELEVATION
22.86
22.86
22.86
SURFACE LOAD
ASTM LOAD LEVEL 4
FRAME & COVER
2EA 030"
2EA 030"
>130"
WETLANDMEDIA VOLUME (CY)
4.12
ORIFICE SIZE (DIA. INCHES)
5 EA 01.32"
NOTES. -
INLET PIPE
SEE NOTES
PLAN VIEW
22.86 2'-0" RISER
R/M/FG HEIGHT
INSTALLATION NOTES T
11
1. CONTRACTOR TO PROVIDE ALL LABOR, EQUIPMENT, MATERIALS AND 20.12
TOP SLAB ELEV
INCIDENTALS REQUIRED TO OFFLOAD AND INSTALL THE SYSTEM AND
APPURTENANCES IN ACCORDANCE WITH THIS DRAWING AND THE
MANUFACTURERS' SPECIFICATIONS, UNLESS OTHERWISE STATED IN
MANUFACTURERS CONTRACT.
2. UNIT MUST BE INSTALLED ON LEVEL BASE. MANUFACTURER
RECOMMENDS A MINIMUM 6" LEVEL ROCK BASE UNLESS SPECIFIED BY I
THE PROJECT ENGINEER. CONTRACTOR IS RESPONSIBLE FOR VERIFYING 16.16 ' _ _ _ _ _ _ _
PROJECT ENGINEER'S RECOMMENDED BASE SPECIFICATIONS. PEAK HGL
4. CONTRACTOR TO SUPPLY AND INSTALL ALL EXTERNAL CONNECTING
PIPES. ALL PIPES MUST BE FLUSH WITH INSIDE SURFACE OF 14.70
CONCRETE (PIPES CANNOT INTRUDE BEYOND FLUSH). INVERT OF lE /N
OUTFLOW PIPE MUST BE FLUSH WITH DISCHARGE CHAMBER FLOOR.
0
ALL PIPES SHALL BE SEALED WATERTIGHT PER MANUFACTURER'S
STANDARD CONNECTION DETAIL.
5. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF ALL PIPES, RISERS,
' UNDERORA/N
MANIFOLD
OUTLET PIPE
SEE NOTES
�r
MANHOLES, AND HATCHES. CONTRACTOR TO USE GROUT AND/OR 6" 12�- O" r-6"
BRICKS TO MATCH COVERS WITH FINISHED SURFACE UNLESS SPECIFIED 13'-0"
OTHERWISE. ELEVATION VIEW
6. VEGETATION SUPPLIED AND INSTALLED BY OTHERS. ALL UNITS WITH
VEGETATION MUST HAVE DRIP OR SPRAY IRRIGATION SUPPLIED AND INSTALLED BY OTHERS. INTERNAL BYPASS DISCLOSURE:
7. CONTRACTOR RESPONSIBLE FOR CONTACTING BIO CLEAN FOR
ACTIVATION OF UNIT. MANUFACTURERS WARRANTY IS VOID WITHOUT
PROPER ACTIVATION BY A BIO CLEAN REPRESENTATIVE.
GENERAL NOTES
1. MANUFACTURER TO PROVIDE ALL MATERIALS UNLESS OTHERWISE NOTED.
2. ALL DIMENSIONS, ELEVATIONS, SPECIFICATIONS AND CAPACITIES ARE SUBJECT TO
CHANGE. FOR PROJECT SPECIFIC DRAWINGS DETAILING EXACT DIMENSIONS, WEIGHTS
AND ACCESSORIES PLEASE CONTACT BIO CLEAN.
PLAN VIEW
4" MIN.
16" MAX.
T\�
ALTERNATIVE NOTCH WEIR
MAY BE SPECIFIED -
SEE DETAIL
SET OVERFLOW ELEVATION
TO PROVIDE DETENTION AS
SHOWN IN THE CONTRACT
PIPE SUPPORT;
3" (IN) x 0.075" (IN) ALUMINU,
OR 3" (IN) x 0.079" (IN)
STEEL (SEE NOTE 1)
12"
OUTLET
MORTAR (TYP.) J
FLOW RESTRICTOR
RESTRICTOR PLATE
WITH ORIFICE
(SEE NOTE 6)
MANHOLE RING AND COVER
WITH LOCKING BOLTS,
MARKED "DRAIN"
�J
INLET
N
N 54" DIAM. MIN.
THE DESIGN AND CAPACITY OF THE PEAK CONVEYANCE METHOD TO BE REVIEWED
AND APPROVED BY THE ENGINEER OF RECORD. HGL(S) AT PEAK FLOW SHALL BE
ASSESSED TO ENSURE NO UPSTREAM FLOODING. PEAK HGL AND BYPASS
CAPACITY SHOWN ON DRAWING ARE USED FOR GUIDANCE ONLY.
ADJUSTABLE LOCK HOOK
WITH LOCK SCREW
1" (IN) DIAM. ROD OR TUBING
LIFT HANDLE
ATTACHMENT
LIFT HANDLE
0
0 0
0
MAXIMUM OPENING
1/2" (IN) HOLE ON 10 3/8" (IN)
BOLT CIRCLE (TYP)
0 0
0` ,o
LEVEL LINE 0
(SEE NOTE 7) CLOSED
FRONT SIDE
STEPS OR LADDER
LIFT HANDLE
SHEAR GATE -
8" (IN) MIN. DIAM.
SHEAR GATE DETAILS
WEIR LENGTH AND ELEVATION
AS SPECIFIED IN CONTRACT
SECTION O FLOW CONTROL STRUCTURE DETAILS
RISER DIAMETER: 18"
RISER HEIGHT: 5'
TOP OF RISER: 19.86
ORIFICE 1 DIA: 2.75"
ORIFICE 1 ELEVATION: 14.86'
NOTCH WIDTH: -0.75"
NOTCH HEIGHT: 2.25'
FLOW CONTROL STRUCTURE DETAIL
NOTCH WEIR DETAIL
MANHOLE MANHOLE
C/L
1
6"i
9 =0"
LEFT END VIEW
RIGHT END VIEW
NOTES
1. The pipe supports and the flow restrictor shall be constructed of the same material and be anchored
at a maximum spacing of 36" (in). Attach the pipe supports to the manhole with 5/8" (in) stainless
steel expansion bolts or embed the supports into the manhole wall 2" (in).
2. The vertical riser stem of the flow restrictor shall be the same diameter as the horizontal outlet
pipe with a minimum diameter of 12" (in).
3. The flow restrictor shall be fabricated from one of the following materials:
0.060" (in) Corrugated Aluminum Alloy Drain Pipe
0.064" (in) Corrugated Galvanized Steel Drain Pipe with Treatment 1
0.064" (in) Corrugated Aluminized Steel Drain Pipe
0.060" (in) Aluminum alloy flat sheet, in accordance with ASTM B 209, 5062 H32 or EPS
High Density Polyethylene Storm Sewer Pipe
4. The frame and ladder or steps are to be offset so that: the shear gate is visible from the top;
the climb -down space is clear of the riser and gate; the frame is clear of the curb.
5. The multi -orifice elbows may be located as shown, or all placed on one side of the riser to assure ladder
clearance. The size of the elbows and their placement shall be specified in the Contract.
6. Restrictor plate with orifice as specified in the Contract. The opening is to be cut round and smooth.
7. The shear gate shall be made of aluminum alloy in accordance with ASTM B 26 and ASTM B 275,
designation ZG32A; or cast iron in accordance with ASTM A 48, Class 30B.
The lift handle shall be made of a similar metal to the gate (to prevent galvanic corrosion), it may
be of solid rod or hollow tubing, with adjustable hook as required.
A neoprene rubber gasket is required between the riser mounting flange and the gate flange.
Install the gate so that the level -line mark is level when the gate is closed.
The mating surfaces of the lid and the body shall be machined for proper fit.
All shear gate bolts shall be stainless steel.
8. The shear gate maximum opening shall be controlled by limited hinge movement,
a stop tab, or some other device.
9. Alternative shear gate designs are acceptable if material specifications are met.
OVERFLOW ELEVATION
AS SPECIFIED IN CONTRACT
NTS
REMOVABLE
WATERTIGHT
COUPLING
PLATE WITH
ORIFICE
ELBOW DETAIL
0
\l91
WASyj��
41819
BC18TV, 1�
BSI®NA9
Aug 17, 2021
CATCH BASIN TYPE 2
WITH FLOW RESTRICTOR
STANDARD PLAN B-10.40-02
SHEET 1 OF 1 SHEET
APPROVED FOR PUBLICATION
Aug 17, 2021
STATE DESIGN ENGINEER
Washington State Department of Transportation
-" CCP SUBMITTAL #1
REVISION
/10
suRVEYED:04/01 /21
DESIGNED: AD/CH/NW
DRAWN: AD/CH/NW
CHECKED: CM
►_1»:a maim
SCALE:
AS SHOWN
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
CITY OF
RENTON
Planning/Building/Public Works Dept.
M
L0
N
O
N
N
U
N
Q
J
C'7
O
O
C)
N
R-422016 �ssloAL
N��1.
01 /04/2023
O
IN COMPLIANCE WITH CITY OF RENTON STANDARDS (J
V
DEVELOPMENT ENGINEERING 0 z
JChavez 01 /31 /2023
DATE:
600 SW 10TH PARKING LOT 08/30/2022
FlELDBOOK:
PAGE:
STORM DRAIN & S T O R M WAT E R DRAWING NO: U)
MANAGEMENT DETAILS C-508 O
SHEET: ---- OF: 22 O