HomeMy WebLinkAboutR-422017O N N I O I 0 W 00 L0 I U w Q Z J U_ SITE SPECIFIC DATA PROJECT NUMBER 15274 PROJECT NAME 600 SW LOTH PARKING LOT PROJECT LOCATION RENTON, WA STRUCTURE ID N/A TREATMENT REQUIRED VOLUME BASED (CF) FLOW BASED (CFS) N/A 0.25 PEAK BYPASS REQUIRED (CFS) - IF APPLICABLE 1.17 PIPE DATA LE. MATERIAL DIAMETER INLET PIPE 1 14.70 PVC 12" OUTLET PIPE 13.41 PVC 12" PRETREATMENT BIORLTR4TION DISCHARGE RIM ELEVATION 22.86 22.86 22.86 SURFACE LOAD ASTM LOAD LEVEL 4 FRAME & COVER 2EA 030" 2EA 030" >130" WETLANDMEDIA VOLUME (CY) 4.12 ORIFICE SIZE (DIA. INCHES) 5 EA 01.32" NOTES. - INLET PIPE SEE NOTES PLAN VIEW 22.86 2'-0" RISER R/M/FG HEIGHT INSTALLATION NOTES T 11 1. CONTRACTOR TO PROVIDE ALL LABOR, EQUIPMENT, MATERIALS AND 20.12 TOP SLAB ELEV INCIDENTALS REQUIRED TO OFFLOAD AND INSTALL THE SYSTEM AND APPURTENANCES IN ACCORDANCE WITH THIS DRAWING AND THE MANUFACTURERS' SPECIFICATIONS, UNLESS OTHERWISE STATED IN MANUFACTURERS CONTRACT. 2. UNIT MUST BE INSTALLED ON LEVEL BASE. MANUFACTURER RECOMMENDS A MINIMUM 6" LEVEL ROCK BASE UNLESS SPECIFIED BY I THE PROJECT ENGINEER. CONTRACTOR IS RESPONSIBLE FOR VERIFYING 16.16 ' _ _ _ _ _ _ _ PROJECT ENGINEER'S RECOMMENDED BASE SPECIFICATIONS. PEAK HGL 4. CONTRACTOR TO SUPPLY AND INSTALL ALL EXTERNAL CONNECTING PIPES. ALL PIPES MUST BE FLUSH WITH INSIDE SURFACE OF 14.70 CONCRETE (PIPES CANNOT INTRUDE BEYOND FLUSH). INVERT OF lE /N OUTFLOW PIPE MUST BE FLUSH WITH DISCHARGE CHAMBER FLOOR. 0 ALL PIPES SHALL BE SEALED WATERTIGHT PER MANUFACTURER'S STANDARD CONNECTION DETAIL. 5. CONTRACTOR RESPONSIBLE FOR INSTALLATION OF ALL PIPES, RISERS, ' UNDERORA/N MANIFOLD OUTLET PIPE SEE NOTES �r MANHOLES, AND HATCHES. CONTRACTOR TO USE GROUT AND/OR 6" 12�- O" r-6" BRICKS TO MATCH COVERS WITH FINISHED SURFACE UNLESS SPECIFIED 13'-0" OTHERWISE. ELEVATION VIEW 6. VEGETATION SUPPLIED AND INSTALLED BY OTHERS. ALL UNITS WITH VEGETATION MUST HAVE DRIP OR SPRAY IRRIGATION SUPPLIED AND INSTALLED BY OTHERS. INTERNAL BYPASS DISCLOSURE: 7. CONTRACTOR RESPONSIBLE FOR CONTACTING BIO CLEAN FOR ACTIVATION OF UNIT. MANUFACTURERS WARRANTY IS VOID WITHOUT PROPER ACTIVATION BY A BIO CLEAN REPRESENTATIVE. GENERAL NOTES 1. MANUFACTURER TO PROVIDE ALL MATERIALS UNLESS OTHERWISE NOTED. 2. ALL DIMENSIONS, ELEVATIONS, SPECIFICATIONS AND CAPACITIES ARE SUBJECT TO CHANGE. FOR PROJECT SPECIFIC DRAWINGS DETAILING EXACT DIMENSIONS, WEIGHTS AND ACCESSORIES PLEASE CONTACT BIO CLEAN. PLAN VIEW 4" MIN. 16" MAX. T\� ALTERNATIVE NOTCH WEIR MAY BE SPECIFIED - SEE DETAIL SET OVERFLOW ELEVATION TO PROVIDE DETENTION AS SHOWN IN THE CONTRACT PIPE SUPPORT; 3" (IN) x 0.075" (IN) ALUMINU, OR 3" (IN) x 0.079" (IN) STEEL (SEE NOTE 1) 12" OUTLET MORTAR (TYP.) J FLOW RESTRICTOR RESTRICTOR PLATE WITH ORIFICE (SEE NOTE 6) MANHOLE RING AND COVER WITH LOCKING BOLTS, MARKED "DRAIN" �J INLET N N 54" DIAM. MIN. THE DESIGN AND CAPACITY OF THE PEAK CONVEYANCE METHOD TO BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD. HGL(S) AT PEAK FLOW SHALL BE ASSESSED TO ENSURE NO UPSTREAM FLOODING. PEAK HGL AND BYPASS CAPACITY SHOWN ON DRAWING ARE USED FOR GUIDANCE ONLY. ADJUSTABLE LOCK HOOK WITH LOCK SCREW 1" (IN) DIAM. ROD OR TUBING LIFT HANDLE ATTACHMENT LIFT HANDLE 0 0 0 0 MAXIMUM OPENING 1/2" (IN) HOLE ON 10 3/8" (IN) BOLT CIRCLE (TYP) 0 0 0` ,o LEVEL LINE 0 (SEE NOTE 7) CLOSED FRONT SIDE STEPS OR LADDER LIFT HANDLE SHEAR GATE - 8" (IN) MIN. DIAM. SHEAR GATE DETAILS WEIR LENGTH AND ELEVATION AS SPECIFIED IN CONTRACT SECTION O FLOW CONTROL STRUCTURE DETAILS RISER DIAMETER: 18" RISER HEIGHT: 5' TOP OF RISER: 19.86 ORIFICE 1 DIA: 2.75" ORIFICE 1 ELEVATION: 14.86' NOTCH WIDTH: -0.75" NOTCH HEIGHT: 2.25' FLOW CONTROL STRUCTURE DETAIL NOTCH WEIR DETAIL MANHOLE MANHOLE C/L 1 6"i 9 =0" LEFT END VIEW RIGHT END VIEW NOTES 1. The pipe supports and the flow restrictor shall be constructed of the same material and be anchored at a maximum spacing of 36" (in). Attach the pipe supports to the manhole with 5/8" (in) stainless steel expansion bolts or embed the supports into the manhole wall 2" (in). 2. The vertical riser stem of the flow restrictor shall be the same diameter as the horizontal outlet pipe with a minimum diameter of 12" (in). 3. The flow restrictor shall be fabricated from one of the following materials: 0.060" (in) Corrugated Aluminum Alloy Drain Pipe 0.064" (in) Corrugated Galvanized Steel Drain Pipe with Treatment 1 0.064" (in) Corrugated Aluminized Steel Drain Pipe 0.060" (in) Aluminum alloy flat sheet, in accordance with ASTM B 209, 5062 H32 or EPS High Density Polyethylene Storm Sewer Pipe 4. The frame and ladder or steps are to be offset so that: the shear gate is visible from the top; the climb -down space is clear of the riser and gate; the frame is clear of the curb. 5. The multi -orifice elbows may be located as shown, or all placed on one side of the riser to assure ladder clearance. The size of the elbows and their placement shall be specified in the Contract. 6. Restrictor plate with orifice as specified in the Contract. The opening is to be cut round and smooth. 7. The shear gate shall be made of aluminum alloy in accordance with ASTM B 26 and ASTM B 275, designation ZG32A; or cast iron in accordance with ASTM A 48, Class 30B. The lift handle shall be made of a similar metal to the gate (to prevent galvanic corrosion), it may be of solid rod or hollow tubing, with adjustable hook as required. A neoprene rubber gasket is required between the riser mounting flange and the gate flange. Install the gate so that the level -line mark is level when the gate is closed. The mating surfaces of the lid and the body shall be machined for proper fit. All shear gate bolts shall be stainless steel. 8. The shear gate maximum opening shall be controlled by limited hinge movement, a stop tab, or some other device. 9. Alternative shear gate designs are acceptable if material specifications are met. OVERFLOW ELEVATION AS SPECIFIED IN CONTRACT NTS REMOVABLE WATERTIGHT COUPLING PLATE WITH ORIFICE ELBOW DETAIL 0 \l91 WASyj�� 41819 BC18TV, 1� BSI®NA9 Aug 17, 2021 CATCH BASIN TYPE 2 WITH FLOW RESTRICTOR STANDARD PLAN B-10.40-02 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Aug 17, 2021 STATE DESIGN ENGINEER Washington State Department of Transportation -" CCP SUBMITTAL #1 REVISION /10 suRVEYED:04/01 /21 DESIGNED: AD/CH/NW DRAWN: AD/CH/NW CHECKED: CM ►_1»:a maim SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. M L0 N O N N U N Q J C'7 O O C) N R-422016 �ssloAL N��1. 01 /04/2023 O IN COMPLIANCE WITH CITY OF RENTON STANDARDS (J V DEVELOPMENT ENGINEERING 0 z JChavez 01 /31 /2023 DATE: 600 SW 10TH PARKING LOT 08/30/2022 FlELDBOOK: PAGE: STORM DRAIN & S T O R M WAT E R DRAWING NO: U) MANAGEMENT DETAILS C-508 O SHEET: ---- OF: 22 O