HomeMy WebLinkAboutP_PLAN_SET_221219_V5hazim@wilsonhajengineers.com
°
°°
S. 172ND STWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTR WTR WTR WTR WTR WTR WTR WTR WTR WTR
WTRWTRWTRWTRWTRWTRWTRWTRWTR WTR WTR WTR WTR WTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTR
WTRTALBOT ROAD20' bsbl
15' bsbl20' bsbl 5' bsbl580 asphalt
driveway
657.47' s89°22'51"e
844.77' s89°25'03"e
166.39' n01°54'00"e184.32' s89°25'03"e
30.00' n03°38'37"w
136.03' n01°52'12"e20'
b
s
b
l15' b
s
bl
5.1'
5.1'
GARAGE
768 SQFT
RESIDENCE
2645 SQFT
SCALE: 1" = 40'
10'20'0 40'
SCALE: 1" = 200'
10'20'0 40'
C1 1
project site
WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR
WTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTR WTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTRWTR
WTRWTRWTR20' bsbl
15' bsbl20' bsbl 5' bsbl580 asphalt
driveway
657.47' s89°22'51"e
844.77' s89°25'03"e
166.39' n01°54'00"e20'
b
s
b
l15' bsbl
5.1'
5.1'
GARAGE
768 SQFT
RESIDENCE
2645 SQFT
IMPERVIOUS AREAS
PLAN# SINGH RESIDENCE
ZONE R-8
MAIN FLOOR: 2660 SQFT
SUBTOTAL 2660 SQFT
DRIVEWAY: 323 SQFT
TOTAL IMPERVIOUS: 2983 SQFT
TOTAL LOT AREA: 114,797 SQFT
BUILDING IMPERV % 2.3%
TOTAL IMPERV % 2.6%
SCALE: 1" = 20'
10'20'0 40'
PROPOSED A 2 STORY 5,000 SQFT SINGLE FAMILY
RESIDENCE WITH A 3 CAR TANDEM GARAGE
C1A
1
c 2020 RECTOR RESIDENTIAL DESIGN, LLC
c 2020 RECTOR RESIDENTIAL DESIGN, LLC
c 2020 RECTOR RESIDENTIAL DESIGN, LLC
c 2020 RECTOR RESIDENTIAL DESIGN, LLCc 2020 RECTOR RESIDENTIAL DESIGN, LLC3:123:123:123:123:123:123:123:123:12
3:12
3:12 3:123:123:123:12 3:123:12
3:12
c 2020 RECTOR RESIDENTIAL DESIGN, LLC
c 2020 RECTOR RESIDENTIAL DESIGN, LLCc 2020 RECTOR RESIDENTIAL DESIGN, LLC
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject AddressProject Number
Issue Date
Author
Checker
FOUNDATION
PLANSINGH RESIDENCERAM S.S01 34XX TALBOT RD RENTON WAc 2020 RECTOR RESIDENTIAL DESIGN, LLC
RETAINING WALL FOR 9'
UNBALANCED SOIL HEIGHT
RETAINING WALL FOR 9'
UNBALANCED SOIL HEIGHT
RETAINING WALL FOR 9'
UNBALANCED SOIL HEIGHT
RETAINING WALL FOR 9'
UNBALANCED SOIL HEIGHT
WF1-4
WF1-4
F3-0
F3-0
F3-0
F3-0
F3-0
F3-0
F4-0
F4-0
STAIR LOCATION SEE ARCH
DRAWINGS & DETAIL 3/SD3.1
FOR FOOTING DETAILS
RETAINING WALL FOR 9'
UNBALANCED SOIL HEIGHT
VERIFY
RETAINING WALL FOR 9'
UNBALANCED SOIL HEIGHT
RETAINING WALL FOR 9'
UNBALANCED SOIL HEIGHT
6X6 POST
W/CB66
6X6 POST
W/CB66
6X6 POST
W/CB66
6X6 POST
W/CB66
6X6 POST
W/CB66
6X6 POST
W/CB66
6X6 POST
W/CB66
6X6 POST
W/CB66
6X6 POST
W/CB66
RETAINING WALL FOR 9'
UNBALANCED SOIL HEIGHT
1
SD01.1
1
SD01.1
1
SD01.1
1
SD01.1
1
SD01.1
F2-6
F2-6
8" TYP.
8" TYP.
8" TYP.
8" TYP.8" TYP.8" TYP.8" TYP.8" TYP.8" TYP.2.5' TOE
2.5' TOE
2.5' TOE
3.5' HEEL
3.5' HEEL
3.5' HEEL
1
SD01.12.5' TOE2.5' TOE2.5' TOE2.5' TOE2.5' TOE3.5' HEEL3.5' HEEL3.5' HEEL3.5' HEEL3.5' HEEL3.5' HEEL2.5' TOE4" S.O.G. TYP.
W/ WWF 6X6 - 10/10
OR #3 @ 12" O/C E.W.
U.N.O BY SOIL REPORT
SEE HOLD DOWN LOCATIONS IN S03
SEE GARAGE
FOUNDATION
PLAN IN S02
7
SD01
7
SD01
TYP.
TYP.
04/27/2022
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject AddressProject Number
Issue Date
Author
Checker
MAIN FLR
FRAMING &
GARAGE FTGSINGH RESIDENCERAM S.S02 34XX TALBOT RD RENTON WAc 2020 RECTOR RESIDENTIAL DESIGN, LLC CONT. FTGCONT. FTG4" S.O.G.
W/ WWF 6X6 - 10/10
OR #3 @ 12" O/C E.W.
U.N.O BY SOIL REPORT
LEGEND
XXX
FOUNDATION
ELEVATION
X.XX"DROP OR STEP
FX-X SPREAD FOOTING NUMBER PER SCHEDULE
WFX-X WALL FOOTING NUMBER PER SCHEDULE
XXX WOOD POST OR TRIMMER
DIRECTION OF MEMBERS PER SCHEDULE X
MEMBERS DISTRIBUTION
XXX HOLD-DOWN PER SCHEDULE
X'-X"
WX SHEAR WALL LENGTH AND NUMBER
REFER TO SHEAR WALL SCHEDULE FOR SPEC.
X
S-X
DETAIL NUMBER
SHEET NUMBER
X BEAM NUMBER, REFER TO CALCULATION
REPORT AND BEAM SCHEDULE
KEY NOTE NUMBER X
BEARING WALL HIGHLIGHTED IN GRAY,
OR CALLED OUT
A.B. PER SCH.BRACED WALL
PER SHEAR WALL SCH.
A.B. PER SCH.
12" FROM CORNERS
X'-X"
WX
KEY NOTES
BLOCKED ROOF DIAPHRAGM W/ 10d @ 4" O/C B.N., 4" O/C E.N. & 12" O/C
FIELD 1
2
BLOCKED FLOOR DIAPHRAGM W/ 10d @ 4" O/C B.N., 4" O/C E.N. & 12" O/C
FIELD
3 HEADER, SEE HEADER SCHEDULE
BLOCKING AND CONNECTION SHALL BE PROVIDED AT PANEL EDGES
PERPENDICULAR TO FLOOR FRAMING MEMBERS IN THE FIRST TWO BAYS @ 48"
O/C MAX4
5 HOLD-DOWN ABOVE
HOLD-DOWN
PER SCH.
XXX
XXX
HOLD-DOWN POST
PER SCH.
BEAM/HEADER
JOIST/RAFTER HANGER OR BEAM BRACKET
J11
2
1
Bridging / Blocking
Between Floor Joists (8' o.c. max.)
GLUED & NAILED
11 7/8" TJI® 560D @ 12" OC5 1/2"X13 1/2", 24F-V4DF/DF GL BEAMB03
B03 B01
B01
B02
2
2
2
24'-1"
J12
Bridging / Blocking
Between Floor Joists (8' o.c. max.)
GLUED & NAILED
11 7/8" TJI® 560D @ 12" OC
5 1/2"X13 1/2", 24F-V4DF/DF GL BEAM5 1/2"X13 1/2", 24F-V4DF/DF GL BEAM5 1/2"X13 1/2", 24F-V4DF/DF GL BEAM5 1/2"X13 1/2", 24F-V4DF/DF GL BEAM5 1/2"X13 1/2", 24F-V4DF/DF GL BEAM5 1/2"X13 1/2", 24F-V4DF/DF GL BEAM5 1/2"X13 1/2", 24F-V4DF/DF GL BEAM5 1/2"X13 1/2", 24F-V4DF/DF GL BEAMUSE; CC66
TYP.
USE; CC66
TYP.
STHD14
STHD14
STHD14
STHD14
WF2-6
WF2-6
WF2-6
WF2-6
SEE FOUNDATION SCH.
IN SHEET SD01
04/27/2022
6
SD01
6
SD01
1
SD01.1
1
SD01.1
1
SD01.1
1
SD01.1
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject AddressProject Number
Issue Date
Author
Checker
UPPER FLR
FRAMINGSINGH RESIDENCERAM S.S03 34XX TALBOT RD RENTON WAc 2020 RECTOR RESIDENTIAL DESIGN, LLC
LEGEND
XXX
FOUNDATION
ELEVATION
X.XX"DROP OR STEP
FX-X SPREAD FOOTING NUMBER PER SCHEDULE
WFX-X WALL FOOTING NUMBER PER SCHEDULE
XXX WOOD POST OR TRIMMER
DIRECTION OF MEMBERS PER SCHEDULE X
MEMBERS DISTRIBUTION
XXX HOLD-DOWN PER SCHEDULE
X'-X"
WX SHEAR WALL LENGTH AND NUMBER
REFER TO SHEAR WALL SCHEDULE FOR SPEC.
X
S-X
DETAIL NUMBER
SHEET NUMBER
X
BEAM NUMBER, REFER TO CALCULATION
REPORT AND BEAM SCHEDULE
KEY NOTE NUMBER X
BEARING WALL HIGHLIGHTED IN GRAY,
OR CALLED OUT
A.B. PER SCH.
BRACED WALL
PER SHEAR WALL SCH.
A.B. PER SCH.
12" FROM CORNERS
X'-X"
WX
KEY NOTES
BLOCKED ROOF DIAPHRAGM W/ 10d @ 4" O/C B.N., 4" O/C E.N. & 12" O/C
FIELD 1
2
BLOCKED FLOOR DIAPHRAGM W/ 10d @ 4" O/C B.N., 4" O/C E.N. & 12" O/C
FIELD
3 HEADER, SEE HEADER SCHEDULE
BLOCKING AND CONNECTION SHALL BE PROVIDED AT PANEL EDGES
PERPENDICULAR TO FLOOR FRAMING MEMBERS IN THE FIRST TWO BAYS @ 48"
O/C MAX4
5 HOLD-DOWN ABOVE
HOLD-DOWN
PER SCH.
XXX
XXX
HOLD-DOWN POST
PER SCH.
BEAM/HEADER
JOIST/RAFTER HANGER OR BEAM BRACKET
3333333
3 33
3 3
3
3
3
3 3 3
3
3 3
3
3 3
3
3
HDU4
HDU4
HDU4
2W3
1'-6"
2W3
2'-0"
2W3
2'-0"
W4
HDU4
HDU2
HDU2
HDU2
W4
27'-10"
SEE SHEAR WALL SCH.
SD2.1 TYP.
SEE HOLD-DOWN SCH.
SD2.1 TYP.
FLOOR TO FLOOR
HOLD-DOWN
W4
17'-6"
HDU4HDU4
W3
16'-6"
HDU8
HDU8
W4
21'-6"
HDU4
HDU4
W4
14'-0"
HDU4 HDU4
W4
15'-4"HDU2HDU2
W4
16'-0"HDU2 HDU2
W4
36'-0"
HDU2HDU2
HDU8HDU8
W4
18'-8"
HDU2
HDU2
UPPER FLOOR FRAMING &
MAIN FLOOR SHEAR WALL LOCATIONS
HOLD-DOWNS SHALL BE TO
FOUNDATIONS
W4
13'-4"
B11
5 1/8"X16 1/2", 24F-V4 DF/DF GL BEAMB11
5 1/8"X16 1/2", 24F-V4DF/DF GL BEAMJ21
2
11 7/8" TJI® 560D @ 12" OC
Bridging / Blocking
Between Floor Joists (8' o.c. max.)
GLUED & NAILED
DBL JOIST
2
IUS SIMPS. HANGER
@E.A. JST
3 1/2"X13 1/2", 24F-V4 DF/DF GL BEAM4X4 POST
W/ECC44
4X4 POST
W/ECC44
3 1/2"X13 1/2", 24F-V4
DF/DF GL BEAM
3 1
/
2
"
X
1
3
1
/
2
"
,
2
4
F
-
V
4
D
F
/
D
F
G
L
B
E
A
M
4X4 POST
W/ECC44
4X4 POST
W/ECC44
HUCQ612-SDS3 1/2"X13 1/2", 24F-V4DF/DF GL BEAM3 1/2"X13 1/2", 24F-V4
DF/DF GL BEAM
4X4 POST
W/ECC44
3 1/2"X13 1/2", 24F-V4
DF/DF GL BEAM
3 1/2"X13 1/2", 24F-V4DF/DF GL BEAMHUCQ612-SDS3 1/2"X13 1/2", 24F-V4 DF/DF GL BEAM3 1/2"X13 1/2", 24F-V4 DF/DF GL BEAM3 1/2"X13 1/2", 24F-V4
DF/DF GL BEAM
B13
B14
B16B16B16
B17 B17
B15
B15
B15
4X4 POST
W/ECC444X4 POST
W/ECC44
4X4 POST
W/ECC44
4X4 POST
W/ECC44
4X4 POST
W/ECC44
4X4 POST
W/ECC44
4X4 POST
W/ECC44
6X12, DF. NO.2 BEAM
IUS SIMPS.
HANGERS @
EA. JST TYP.
IUS SIMPS.
HANGERS @
EA. JST TYP.
2
2
8
SD03
04/27/2022
SHEAR WALL SCHEDULE
Label
ANSI/APA Rated
Sheating
[1][2][4][12][13]
Nail Size & Spacing @
Edges [4][5]
Stud &
Blocking
Size @
Adjoining
Edges
[3][6][14]
Rim Joist or
block
connection to
top plate
[7][8]
2X Bottom Plate Attachment Sill Plate Attachment
PLF Capacity
Nailing to Wood Below [9]
Anchor Bolt to
Concrete Below
[10][15]
Sill Plate Size
@ Foundation
[11]
W6 15/32" or 7/16" if [12]applied
one side 0.131x2-1/2 @ 6" O.C.2X6 Clip(A35 or LTP4)@ 24" O.C.0.148x3-1/4" @ 6" O.C.5/8" @ 48" O.C.2X6
W4 0.131x2-1/2 @ 4" O.C.2X6 Clip(A35 or LTP4)@ 16" O.C.0.148x3-1/4" @ 4" O.C.5/8" @ 32" O.C.2X6
W3 0.131x2-1/2 @ 3" O.C.2X6 Clip(A35 or LTP4)@ 12" O.C.
(2) ROWS 0.148x3-1/4" @
4-1/2" O.C.
5/8" @ 16" O.C.2X6
W2 0.131x2-1/2 @ 2" O.C.3X6 Clip(A35 or LTP4)@ 8" O.C.5/8" @ 12" O.C.2X6
2W3[2]0.131x2-1/2 @ 3" O.C. E.A. SIDE 3X6 Clip(A35 or LTP4)@ 12" O.C.
EACH SIDE 5/8" @ 16" O.C.3X6
2W2[2]0.131x2-1/2 @ 2" O.C. E.A. SIDE 3X6 Clip(A35 or LTP4)@ 8" O.C.
EACH SIDE 5/8" @ 12" O.C.3X6
0.148x3-1/4" @ 3" O.C.
(2) ROWS 0.148x3-1/4" @
3" O.C.
(2) ROWS 0.148x3-1/4" @
2" O.C.
Required Notes
[1] Install panels either horizontally or vertically.
[2] Where sheathing is applied on both sides of wall, panel edge joints on 2x framing shall be staggered so that joints on the opposite sides are not located on the same studs.
[3] Blocking is required at all panel edges.
[4] Provide shear wall sheathing and nailing for the entire length of the walls indicated on the plans. Ends of full height walls are designated by exterior of the building, corridors, windows, or doorways or as designated
on plans. See plans for hold-down requirements. (Alternate note: walls designated as perforated shear walls require sheathing above and below all openings).
[5] Sheathing edge nailing is required at all hold-down posts. Edge nailing may also be required to each stud used in built-up hold-down posts. Refer to the hold-down details for additional information.
[6] Intermediate framing to be with 2x minimum members. Field nailing 12" O.C.
[7] Based on 0.131x1-1/2" long nails used to attach framing clips directly to framing. Use 0.131x2-1/2" nails where installed oversheathing.
[8] Framing clips: A35 or LTP4 or approved equivalent.
[9] Where plate attachment specifies (2) rows of nails, provide double joist, rim or equal. Attach per details.
[10] (In Seismic Design Categories D, E & F) Anchor bolts shall be provided with steel plate washers 1/4"x3"x3". Embed anchor bolts 7" minimum into the concrete.
[11] Pressure treated material can cause excessive corrosion in the fasteners. Provide hot-dipped galvanized (electro-plating is not acceptable) nails and connector plates (framing angles, etc.) for all connectors in
contact
with pressure treated framing members.
Alternate Notes
[12] 7/16" APA rated sheathing (OSB) may be used in place of 15/32" sheathing provided that all studs are spaced at 16" O.C.
[13] Where wood sheathing (W) is applied over gypsum sheathing (G), contact the engineer of record for alternate nailing requirements.
[14] At adjoining panel edges, (2) 2x studs nailed together may be used in place of a single 3x stud. Double 2x studs may be connected together by nailing the studs together with 3" long nails of the same spacing and
diameter as the plate nailing.
[15] Contact the engineer of record for adhesive or expansion bolt alternatives to cast-in-place anchor bolts. (Special inspection may be required).
15/32" or 7/16" if [12]applied
one side
15/32" or 7/16" if [12]applied
one side
15/32" or 7/16" if [12]applied
one side
15/32" or 7/16" if [12]applied
two sides
15/32" or 7/16" if [12]applied
two sides
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject AddressProject Number
Issue Date
Author
Checker
ROOF
FRAMINGSINGH RESIDENCERAM S.S04 34XX TALBOT RD RENTON WAc 2020 RECTOR RESIDENTIAL DESIGN, LLC
333
3
33
3
3
333
33333333
333
3
3
3
3
3 3 3
W4
27'-10"
SEE SHEAR WALL SCH.
SD2.1 TYP.HDU2 HDU2
HDU2
SEE HOLD-DOWN SCH.
SD2.1 TYP.
FLOOR TO FLOOR
HOLD-DOWN
LEGEND
XXX
FOUNDATION
ELEVATION
X.XX"DROP OR STEP
FX-X SPREAD FOOTING NUMBER PER SCHEDULE
WFX-X WALL FOOTING NUMBER PER SCHEDULE
XXX WOOD POST OR TRIMMER
DIRECTION OF MEMBERS PER SCHEDULE X
MEMBERS DISTRIBUTION
XXX HOLD-DOWN PER SCHEDULE
X'-X"
WX SHEAR WALL LENGTH AND NUMBER
REFER TO SHEAR WALL SCHEDULE FOR SPEC.
X
S-X
DETAIL NUMBER
SHEET NUMBER
X BEAM NUMBER, REFER TO CALCULATION
REPORT AND BEAM SCHEDULE
KEY NOTE NUMBER X
BEARING WALL HIGHLIGHTED IN GRAY,
OR CALLED OUT
A.B. PER SCH.BRACED WALL
PER SHEAR WALL SCH.
A.B. PER SCH.
12" FROM CORNERS
X'-X"
WX
KEY NOTES
BLOCKED ROOF DIAPHRAGM W/ 10d @ 4" O/C B.N., 4" O/C E.N. & 12" O/C
FIELD 1
2
BLOCKED FLOOR DIAPHRAGM W/ 10d @ 4" O/C B.N., 4" O/C E.N. & 12" O/C
FIELD
3 HEADER, SEE HEADER SCHEDULE
BLOCKING AND CONNECTION SHALL BE PROVIDED AT PANEL EDGES
PERPENDICULAR TO FLOOR FRAMING MEMBERS IN THE FIRST TWO BAYS @ 48"
O/C MAX4
5 HOLD-DOWN ABOVE
HOLD-DOWN
PER SCH.
XXX
XXX
HOLD-DOWN POST
PER SCH.
BEAM/HEADER
JOIST/RAFTER HANGER OR BEAM BRACKET
HDU2
W4
W4
HDU2
HDU2
HDU4HDU4
W4
18'-8"
W4
13'-4"HDU2HDU2
W4
16'-0"HDU2HDU2
W4
15'-4"
HDU2HDU2W4
14'-0"
HDU4 HDU4
W4
21'-6"
HDU2
HDU2
W4
16'-6"
HDU2
HDU2
HDU4
HDU4W4
17'-6"
ROOF FRAMING & UPPER FLOOR SHEAR
WALL LOCATIONS.
HOLD-DOWNS SHALL BE FLOOR TO FLOOR
1
SEE SHEET S00 FOR ROOF
SHEATHING
2X6, DF. NO.2, FINK TYPE
WOOD TRUSS @ 24" O/C (DESIGN BY OTHERS)
RATING OF APPROVED CONNECTOR
(ASD)=358LB @ EA.END
1
SD04
1
SD04
2
SD04
04/27/2022
SHEAR WALL SCHEDULE
Label
ANSI/APA Rated
Sheating
[1][2][4][12][13]
Nail Size & Spacing @
Edges [4][5]
Stud &
Blocking
Size @
Adjoining
Edges
[3][6][14]
Rim Joist or
block
connection to
top plate
[7][8]
2X Bottom Plate Attachment Sill Plate Attachment
PLF Capacity
Nailing to Wood Below [9]
Anchor Bolt to
Concrete Below
[10][15]
Sill Plate Size
@ Foundation
[11]
W6 15/32" or 7/16" if [12]applied
one side 0.131x2-1/2 @ 6" O.C.2X6 Clip(A35 or LTP4)@ 24" O.C.0.148x3-1/4" @ 6" O.C.5/8" @ 48" O.C.2X6
W4 0.131x2-1/2 @ 4" O.C.2X6 Clip(A35 or LTP4)@ 16" O.C.0.148x3-1/4" @ 4" O.C.5/8" @ 32" O.C.2X6
W3 0.131x2-1/2 @ 3" O.C.2X6 Clip(A35 or LTP4)@ 12" O.C.
(2) ROWS 0.148x3-1/4" @
4-1/2" O.C.
5/8" @ 16" O.C.2X6
W2 0.131x2-1/2 @ 2" O.C.3X6 Clip(A35 or LTP4)@ 8" O.C.5/8" @ 12" O.C.2X6
2W3[2]0.131x2-1/2 @ 3" O.C. E.A. SIDE 3X6 Clip(A35 or LTP4)@ 12" O.C.
EACH SIDE 5/8" @ 16" O.C.3X6
2W2[2]0.131x2-1/2 @ 2" O.C. E.A. SIDE 3X6 Clip(A35 or LTP4)@ 8" O.C.
EACH SIDE 5/8" @ 12" O.C.3X6
0.148x3-1/4" @ 3" O.C.
(2) ROWS 0.148x3-1/4" @
3" O.C.
(2) ROWS 0.148x3-1/4" @
2" O.C.
Required Notes
[1] Install panels either horizontally or vertically.
[2] Where sheathing is applied on both sides of wall, panel edge joints on 2x framing shall be staggered so that joints on the opposite sides are not located on the same studs.
[3] Blocking is required at all panel edges.
[4] Provide shear wall sheathing and nailing for the entire length of the walls indicated on the plans. Ends of full height walls are designated by exterior of the building, corridors, windows, or doorways or as designated
on plans. See plans for hold-down requirements. (Alternate note: walls designated as perforated shear walls require sheathing above and below all openings).
[5] Sheathing edge nailing is required at all hold-down posts. Edge nailing may also be required to each stud used in built-up hold-down posts. Refer to the hold-down details for additional information.
[6] Intermediate framing to be with 2x minimum members. Field nailing 12" O.C.
[7] Based on 0.131x1-1/2" long nails used to attach framing clips directly to framing. Use 0.131x2-1/2" nails where installed oversheathing.
[8] Framing clips: A35 or LTP4 or approved equivalent.
[9] Where plate attachment specifies (2) rows of nails, provide double joist, rim or equal. Attach per details.
[10] (In Seismic Design Categories D, E & F) Anchor bolts shall be provided with steel plate washers 1/4"x3"x3". Embed anchor bolts 7" minimum into the concrete.
[11] Pressure treated material can cause excessive corrosion in the fasteners. Provide hot-dipped galvanized (electro-plating is not acceptable) nails and connector plates (framing angles, etc.) for all connectors in
contact
with pressure treated framing members.
Alternate Notes
[12] 7/16" APA rated sheathing (OSB) may be used in place of 15/32" sheathing provided that all studs are spaced at 16" O.C.
[13] Where wood sheathing (W) is applied over gypsum sheathing (G), contact the engineer of record for alternate nailing requirements.
[14] At adjoining panel edges, (2) 2x studs nailed together may be used in place of a single 3x stud. Double 2x studs may be connected together by nailing the studs together with 3" long nails of the same spacing and
diameter as the plate nailing.
[15] Contact the engineer of record for adhesive or expansion bolt alternatives to cast-in-place anchor bolts. (Special inspection may be required).
15/32" or 7/16" if [12]applied
one side
15/32" or 7/16" if [12]applied
one side
15/32" or 7/16" if [12]applied
one side
15/32" or 7/16" if [12]applied
two sides
15/32" or 7/16" if [12]applied
two sides
WITHIN AN AREA A MINIMUM OF 5 FEET BEYOND THE BUILDING LIMITS,
EXCAVATE A MINIMUM OF 4" OF EXISTING SOIL. REMOVE ALL ORGANICS,
PAVEMENT, ROOTS, DEBRIS AND OTHERWISE UNSUITABLE MATERIAL.
1.
SITE PREPARATION NOTES:
THE SURFACE OF THE EXPOSED SUBGRADE SHALL BE INSPECTED BY
PROBING OR TESTING TO CHECK FOR POCKETS OF SOFT OR UNSUITABLE
MATERIAL. EXCAVATE UNSUITABLE SOIL AS DIRECTED BY THE
GEOTECHNICAL ENGINEER/TESTING AGENCY.
2.
PROOFROLL THE SURFACE OF THE EXPOSED SUBGRADE WITH A LOADED
TANDEM AXLE DUMP TRUCK. REMOVE ALL SOILS WHICH PUMP OR DO
NOT COMPACT PROPERLY AS DIRECTED BY THE GEOTECHNICAL ENGINEER/
TESTING AGENCY.
3.
FILL ALL EXCAVATED AREAS WITH APPROVED CONTROLLED FILL. PLACE
IN 8 INCH LOOSE LIFTS AND COMPACT TO A MINIMUM OF 95% OF THE
MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D-698.
4.
ALL CONTROLLED FILL MATERIAL SHALL BE A SELECT GRANULAR
MATERIAL FREE FROM ALL ORGANICS OR OTHERWISE DELETERIOUS
MATERIAL WITH NOT MORE THAN 20% BY WEIGHT PASSING A NO. 200
SIEVE (CLASSIFIED AS SC, SM, SP OR BETTER IN ACCORDANCE WITH
THE UNIFIED SOIL CLASSIFICATION SYSTEM) AND WITH A PLASTICITY
INDEX NOT EXCEEDING 6%.
5.
PROVIDE FIELD DENSITY TESTS FOR EACH 3,000 S.F. OF BUILDING
AREA FOR EACH LIFT OF CONTROLLED FILL.
6.
THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE
DRAWINGS OF ALL OTHER DISCIPLINES AND THE SPECIFICATIONS. THE
CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF OTHER TRADES AS TO
SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS, HOLES AND OTHER
ITEMS TO BE PLACED OR SET IN THE STRUCTURAL WORK.
1.
GENERAL STRUCTURAL NOTES:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY
PRECAUTIONS AND REGULATIONS DURING THE WORK. THE ENGINEER WILL NOT
ADVISE ON NOR ISSUE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS.
2.
THE STRUCTURAL DRAWINGS HEREIN REPRESENT THE FINISHED STRUCTURE.
THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED
TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL
WORK AND CONNECTIONS HAVE BEEN COMPLETED. THE INVESTIGATION, DESIGN,
SAFETY, ADEQUACY AND INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY
SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
3.
THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES
AND SEQUENCES OF PROCEDURES TO PERFORM THE WORK. THE SUPERVISION
OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
4.
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.
WHERE CONDITIONS ARE NOT SPECIFICALLY SHOWN, SIMILAR DETAILS OF
CONSTRUCTION SHALL BE USED, SUBJECT TO APPROVAL BY THE ENGINEER.
5.
ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO
BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING MANU-
FACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE
WITH THE SUPPLIER'S INSTRUCTIONS AND REQUIREMENTS.
6.
CONCRETE MIX DESIGN (S).A.
REINFORCING STEEL SHOP DRAWINGS.B.
STRUCTURAL STEEL SHOP DRAWINGS.C.
STEEL JOIST /GIRDER SHOP DRAWINGS.D.
METAL DECKING SHOP DRAWINGS.E.
PRE-MANUFACTURED WOOD SYSTEM/TRUSS SHOP DRAWINGS (SEE NOTES).F.
PRE-ENGINEERED METAL BUILDING SYSTEM (SEE NOTES).G.
LOADING APPLIED TO THE STRUCTURE DURING THE PROCESS OF CONSRUCT-
ION SHALL NOT EXCEED THE SAFE LOAD-CARRYING CAPACITY OF THE
STRUCTURAL MEMBERS. THE LIVE LOADINGS UESD IN THE DESIGN OF THIS
STRUCTURE ARE INDICATED IN THE "DESIGN CRITERIA NOTES". DO NOT
APPLY ANY CONSTRUCTION LOADS UNTIL STRUCTURAL FRAMING IS PROPERLY
CONNECTED TOGETHER AND UNTIL ALL TEMPORARY BRACING IS IN PLACE.
7.
ALL ASTM AND OTHER REFERENCES ARE PER THE LATEST EDITIONS OF
THESE STANDARDS, UNLESS OTHERWISE NOTED.
8.
SHOP DRAWINGS AND OTHER ITEMS SHALL BE SUBMITTED TO THE ENGINEER FOR
REVIEW PRIOR TO FABRICATION. ALL SHOP DRAWINGS SHALL BE REVIEWED BY
THE GENERAL CONTRACTOR BEFORE SUBMITTAL. THE ENGINEER'S REVIEW IS TO BE
FOR CONFORMANCE WITH THE DESIGN CONCEPT AND GENERAL COMPLIANCE WITH THE
RELEVANT CONTRACT DOCUMENTS. THE ENGINEER'S REVIEW DOES NOT RELIEVE
THE CONTRACTOR OF THE SOLE RESPONSIBILITY TO REVIEW, CHECK AND COORDINATE
THE SHOP DRAWINGS PRIOR TO SUBMISSION. THE CONTRACTOR REMAINS SOLEY
RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF
SHOP DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, DIMENSIONS, ETC.
9.
SUBMIT SHOP DRAWINGS IN THE FORM OF TWO BLUELINE PRINTS AND ONE SEPIA.
IN NO CASE SHALL REPRODUCTION OF THE CONTRACT DRAWINGS BE USED AS SHOP
DRAWINGS. AS A MINIMUM, SUBMIT THE FOLLOWING ITEMS FOR REVIEW:
10.
OTHER SUBMITTALS MAY BE REQUIRED PER THE "SCHEDULE OF SPECIAL
INSPECTIONS" OR THE SEPARATE NOTES CONTAINED HEREIN.
CONTRACTORS SHALL VISIT THE SITE PRIOR TO BID TO ASCERTAIN
CONDITIONS WHICH MAY ADVERSELY AFFECT THE WORK OR COST THEREOF.
13.
UNLESS OTHERWISE INDICATED, ALL ITEMS NOTED TO BE DEMOLISHED SHALL
BECOME THE CONTRACTOR'S PROPERTY AND BE REMOVED FROM THE SITE.
12.
IN ACCORDANCE WITH SECTION 1705 OF IBC 2018, SPECIAL INSPECTIONS
WILL NOT BE REQUIRED FOR THIS PROJECT. SPECIAL INSPECTIONS SHALL BE PERFORMED
IN ACCORDANCE WITH THE "SCHEDULE OF SPECIAL INSPECTIONS". ALL FABRICATORS
SHALL SATISFY THE "EXCEPTION" NOTED IN SECTION 1705.2, WHICH REQUIRES
THE FABRICATOR TO MAINTAIN AN AGREEMENT WITH AN APPROVED INDEPENDENT
INSPECTION OR QUALITY CONTROL AGENCY. THE CONTRACTOR SHALL NOTIFY THE
SPECIAL INSPECTOR AT LEAST 48 HOURS IN ADVANCE FOR WORK THAT WILL REQUIRE
INSPECTION OR TESTING.
11.
THE LATERAL LOAD RESISTING SYSTEM OF THIS BUILDING CONSISTS OF: SEE S00.16.
DESIGN SNOW LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE AS FOLLOWS: SEE S00.15.
DESIGN LATERAL LIVE LOADS USED IN THE DESIGN OF THIS STRUCTURE
ARE AS FOLLOWS: SEE S00.1
4.
FLOOR LIVE LOAD REDUCTION PER IBC 2018, 1607.11.1 HAS BEEN UTILIZED.
ROOF LIVE LOAD REDUCTION PER IBC 2018, 1607.13.2 HAS BEEN UTILIZED.
ROOF, TYPICAL 20 PSF MIN.ROOF, OVERHANGS 60 PSF
FIRST FLOOR 150 PSF DWELLING UNITS 40 PSF
LOBBIES & STAIRS 100 PSF BALCONIES 100 PSF
MEZZANINE 150 PSF LIGHT STORAGE 125 PSF
CORRIDORS 80 PSF OVERHEAD CRANES X TONS
MECHANICAL SPACE 125 PSF ELEVATOR EQUIP. RM.125 PSF
OFFICES 50 PSF HEAVY STORAGE 250 PSF
DESIGN GRAVITY LIVE LOADS USED IN THE DESIGN OF THIS STRUCTURE
ARE AS FOLLOWS:
3.
DESIGN GRAVITY DEAD LOADS USED IN THE DESIGN OF THIS STRUCTURE
ARE AS FOLLOWS:
2.
ROOF 15 PSF MAX.5 PSF MIN.
FLOORS-TYPICAL 15 PSF
-MEZZANINES X PSF
PARTITION ALLOWANCE 15 PSF
ALL OTHER ACTUAL WEIGHT
DESIGN CRITERIA NOTES:
THE INTENDED DESIGN STANDARDS AND/OR CRITERIA ARE AS FOLLOWS:1.
GENERAL INTERNATIONAL BUILDING CODE (IBC 2018, AS AMENDED)
CONCRETE ACI 318-14
MASONRY ACI 530/530.1-13
STRUCTURAL STEEL ANSI/AISC 360-16 & ANSI/AISC 341-16
STEEL JOISTS/GIRDERS SJI 100-15
METAL DECK SDI NC -17
COLD-FORMED METAL AISI S100-16
WOOD ANSI/AWC NDS-18
WOOD TRUSSES TPI 1-2014
FOUNDATIONS SOILS INVESTIGATION AND REPORT PERFORMED BY XXX
(& 50-YEAR JOIST DIGEST)
BEFORE PROCEEDING WITH ANY WORK WITHIN THE EXISTING FACILITY, THE
CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH EXISTING STRUCTURAL AND OTHER
CONDITIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE
ALL NECESSARY BRACING, SHORING AND OTHER SAFEGUARDS TO MAINTAIN
ALL PARTS OF THE EXISTING WORK IN A SAFE CONDITION DURING THE
PROCESS OF DEMOLITION AND CONSTRUCTION AND TO PROTECT FROM DAMAGE
THOSE PORTIONS OF THE EXISTING WORK WHICH ARE TO REMAIN.
1.
EXISTING CONSTRUCTION NOTES:
THE CONTRACTOR SHALL FIELD VERIFY THE DIMENSIONS, ELEVATIONS, ETC.
NECESSARY FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF THE NEW
PORTIONS OF THE WORK TO THE EXISTING WORK. THE CONTRACTOR SHALL
MAKE ALL MEASUREMENTS NECESSARY FOR FABRICATION AND ERECTION OF
STRUCTURAL MEMBERS. ANY DISCREPANCY SHALL BE IMMEDIATELY
BROUGHT TO THE ATTENTION OF THE ENGINEER.
2.
WELDING TO AND WITHIN AN EXISTING FACILITY PRESENTS POTENTIAL HAZARDS,
INCLUDING:
3.
A.FIRE HAZARD-DUE TO THE EXISTING CONSTRUCTION AND BUILDING CONTENTS.
B.STRUCTURAL LIQUEFACTION-DUE TO WELDING ACROSS THE FULL SECTION
OF STRUCTURAL STEEL MEMBERS.
RECOMMENDATIONS TO PREVENT THESE HAZARDS INCLUDE:
A.FIRE HAZARD-PROTECT EXISTING COMBUSTIBLES PRIOR TO WELDING. KEEP
A SEPARATE WATCHMAN AND SEVERAL FIRE EXTINGUISHERS ON HAND.
C.DO NOT LEAVE THE SITE UNTIL SATISFIED THAT NO FIRE HAZARD EXISTS.
B.STRUCTURAL LIQUEFACTION-WELD IN SMALL INCREMENTS. ALLOW WELDS TO
TO HARDEN BEFORE CONINTUING TO THE NEXT INCREMENT.
INFORMATION USED IN PREPARING THESE DRAWINGS WAS TAKEN FROM
DRAWINGS PREPARED BY THE FIRM OF [ ], DATED [ ].
4.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND
ERECTION OF ALL SHORING NECESSARY TO SAFEGUARD THE EXISTING
STRUCTURE. THE SHORING SHOWN IS A PARTIAL AND SCHEMATIC
REPRESENTATION OF THAT REQUIRED. THE CONTRACTOR SHALL SUBMIT
A DETAILED PLAN FOR SHORING, BRACING AND PROTECTION OF THE EXISTING
CONSTRUCTION. THE PLAN SHALL INCLUDE A CONSTRUCTION SEQUENCE,
BEAR THE SEAL OF A PROFESSIONAL ENGINEER REGISTERED IN THE
COMMONWEALTH OF VIRGINIA AND BE SUBMITTED TO THE ENGINEER FOR
REVIEW PRIOR TO BEGINNING THE WORK.
5.
ALL FOOTINGS SHALL BEAR ON UNDISTURBED, FIRM NATURAL SOIL OR COMPACTED
FILL CAPABLE OF SUPPORTING A DESIGN BEARING PRESSURE OF 1,500 PSF.
ALL FOUNDATION EXCAVATIONS SHALL BE EVALUATED BY THE GEOTECHNICAL
ENGINEER/TESTING AGENCY PRIOR TO POURING FOUNDATION CONCRETE.
1.
FOUNDATION NOTES:
A)CONCRETE CAST AGAINST & PERMANENTLY EXPOSED TO EARTH -3"
B)CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 THROUGH #18 BARS -2"
#5 BAR, W31 OR D31 WIRE & SMALLER -1 1/2"
ALL FOOTINGS HAVE BEEN DESIGNED BASED UPON AN ASSUMED SOIL BEARING
PRESSURE OF 1,500 PSF. ALL FOOTINGS SHALL BEAR ON UNDISTURBED, FIRM
NATURAL SOIL OR COMPACTED FILL. ALL FOUNDATION EXCAVATIONS SHALL BE
EVALUATED BY THE GEOTECHNICAL ENGINEER/TESTING AGENCY PRIOR TO
POURING FOUNDATION CONCRETE.
2.
ALL REINFORCING MARKED CONTINUOUS (CONT.) ON THE PLANS AND
DETAILS SHALL BE LAPPED 58X BAR DIAMETERS AT SPLICES UNLESS
OTHERWISE NOTED.
8.
NO UNBALANCED BACKFILLING SHALL BE DONE AGAINST FOUNDATION
WALLS UNLESS WALLS ARE SECURELY BRACED AGAINST OVERTURNING,
EITHER BY TEMPORARY BRACING OR BY PERMANENT CONSTRUCTION.
9.
PRIOR TO COMMENCING ANY FOUNDATION WORK, COORDINATE WORK WITH
ANY EXISTING UTILITIES. FOUNDATIONS SHALL BE LOWERED WHERE
REQUIRED TO AVOID UTILITIES.
10.
UNLESS OTHERWISE NOTED, THE CENTERLINES OF COLUMN FOUNDATIONS
[PILE CAPS] SHALL BE LOCATED ON COLUMN CENTERLINES.
11.
ALL RETAINING WALLS SHALL HAVE AT LEAST 12" OF FREE-DRAINING
GRANULAR BACKFILL, FULL HEIGHT OF WALL. PROVIDE CONTROL
JOINTS IN RETAINING WALLS AT APPROXIMATELY EQUAL INTERVALS
NOT TO EXCEED 25 FEET NOR 3 TIMES THE WALL HEIGHT. PROVIDE
EXPANSION JOINTS AT EVERY FOURTH CONTROL JOINT, UNLESS
OTHERWISE INDICATED.
12.
TOP OF FOOTING ELEVATION SHALL BE AS SHOWN ON THE FOUNDATION
PLAN. THESE ELEVATIONS ARE A MAXIMUM AND SHALL BE LOWERED AS
REQUIRED TO OBTAIN THE REQUIRED DESIGN BEARING PRESSURE.
3.
ALL FOUNDATION CONCRETE SHALL OBTAIN A 28 DAY COMPRESSIVE
STRENGTH OF 2,500 PSI. ALL CONCRETE TO BE PERMANENTLY EXPOSED TO
WEATHER SHALL BE AIR ENTRAINED TO 5% (±1%) WITH AN ADMIXTURE
THAT CONFORMS TO ASTM C-260.
4.
ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI
301, "SPECIFICATION FOR STRUCTURAL CONCRETE BUILDINGS".
HOT WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 305.
COLD WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 306.
5.
ALL REINFORCING STEEL SHALL CONFORM TO ASTM A-615, GRADE 60.6.
UNLESS OTHERWISE NOTED, THE FOLLOWING MINIMUM CONCRETE COVER
SHALL BE PROVIDED FOR REINFORCEMENT:
7.
PROVIDE CONCRETE SLABS OVER A 6 MIL POLYETHYLENE VAPOR BARRIER
AND 4" OF POROUS FILL AS FOLLOWS:
1.
SLAB ON GRADE NOTES:
ALL OTHER AREAS-4" SLAB REINFORCED WITH WWF 6X6 -10/10 U.N.O.
WELDED WIRE FABRIC OR #3 @ 12" O/C E.W. AND WITH 2,500 PSI MIX CONCRETE.
MAXIMUM SLUMP FOR ALL CONCRETE SLABS SHALL BE 5 INCHES,
USING TYPE II CEMENT.
ALL WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A-185.
LAP ADJOINING PIECES AT LEAST ONE FULL MESH.
2.
ALL POROUS FILL MATERIAL SHALL BE A CLEAN GRANULAR MATERIAL
WITH I00% PASSING A 1 1/2" SIEVE AND NO MORE THAN 5% PASSING
A NO.4 SIEVE. POROUS FILL SHALL BE COMPACTED TO 95%
MAX. DRY DENSITY PER ASTM D-698.
3.
SLAB JOINTS SHALL BE FILLED WITH APPROVED MATERIAL. THIS
SHOULD TAKE PLACE AS LATE AS POSSIBLE, PREFERABLY 4 TO 6
WEEKS AFTER THE SLAB HAS BEEN CAST. PRIOR TO FILLING, REMOVE
ALL DEBRIS FROM THE SLAB JOINTS, THEN FILL IN ACCORDANCE WITH
THE MANUFACTURER'S RECOMMENDATIONS AS FOLLOWS:
4.
6" SLABS -FILL WITH EPOXY RESIN
OTHER SLABS-FILL WITH FIELD MOLDED OR ELASTOMERIC SEALANT
UNLESS OTHERWISE APPROVED, ALL WELDED WIRE FABRIC SHALL BE
BLOCKED INTO THE POSITION INDICATED WITH PRECAST CONCRETE
BLOCKS HAVING A COMPRESSIVE STRENGTH EQUAL TO THAT OF THE SLAB.
5.
WALKWAYS AND OTHER EXTERIOR SLABS ARE NOT INDICATED ON THE
STRUCTURAL DRAWINGS. SEE THE SITE PLAN AND ARCHITECTURAL
DRAWINGS FOR LOCATIONS, DIMENSIONS, ELEVATIONS, JOINTING
DETAILS AND FINISH DETAILS. PROVIDE 4" WALKS REINFORCED
WITH 6X6-W1.4X W1.4 WWF UNLESS OTHERWISE NOTED.
6.
SLABS TO BE PERMANENTLY EXPOSED TO WEATHER SHALL BE AIR ENTRAINED
TO 5% (±1%) WITH AN ADMIXTURE THAT CONFORMS TO ASTM C-260.
7.
ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI
301, "SPECIFICATION FOR STRUCTURAL CONCRETE BUILDINGS".
HOT WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 305.
COLD WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 306.
8.
IN ORDER TO AVOID CONCRETE SHRINKAGE CRACKING, PLACE CONCRETE
SLABS IN AN ALTERNATING LANE (OR CHECKERBOARD) PATTERN. THE
MAXIMUM LENGTH OF SLAB CAST IN ANY ONE CONTINUOUS POUR IS RECOMMENDED
TO BE LESS THAN I00 FEET. THE MAXIMUM SPACING OF JOINTS SHALL BE 25'.
9.
THE ALTERNATE WIRES OF THE WELDED WIRE FABRIC MUST BE PRECUT AT
THE SLAB CONTRACTION JOINT LOCATIONS TO CREATE A "WEAKENED"
PLANE". WITHOUT CUTTING THE ALTERNATE WIRES, THE STRENGTH OF
THE WIRE WILL PREVENT THE SLAB FORM CRACKING (SEPARATING) AT
THE JOINT AND THE SLAB MAY BEGIN TO CRACK ELSEWHERE.
10.
THE USE OF POLYPROPYLENE FIBERS (IN LIEU OF WELDED WIRE FABRIC)
IS PROHIBITED WITHOUT THE WRITTEN AUTHORIZATION OF THE ENGINEER.
11.
SEE THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF DEPRESSED
SLAB AREAS AND DRAINS. SLOPE SLAB TO DRAINS WHERE SHOWN.
12.
CONCRETE MIN. F'C (28 DAYS)SLUMP W/C PATIO
COLUMNS 4000 PSI 2" TO 4".46
ELEVATED SLABS 3000 PSI 2" TO 4".46
CONCRETE NOT NOTED 2500 PSI 2" TO 4".50
FOUNDATION "SEE FDN NOTES"2" TO 4".50
SLABS-ON-GRADE SEE "SLAB-ON-GRADE NOTES".50
CAST-IN-PLACE CONCRETE NOTES:
CONCRETE MIXES SHALL BE DESIGNED PER ACI 301, USING
PORTLAND CEMENT CONFORMING TO ASTM C-150 OR C-595, AGGRE-
GATE CONFORMING TO ASTM C-33, AND ADMIXTURES CONFORMING TO
ASTM C-494, C-1017, C-618, C -989 AND C-260. CONCRETE SHALL
BE READY-MIXED IN ACCORDANCE WITH ASTM C-94.
1.
CONCRETE SHALL CONFORM TO THE FOLLOWING COMPRESSIVE
STRENGTH, SLUMP AND WATER/CEMENT RATIO REQUIREMENTS:
2.
AT CONTRACTOR'S OPTION, AN APPROVED ADMIXTURE MAY BE
USED TO PRODUCE FLOWABLE CONCRETE. MAXIMUM SLUMP SHALL
NOT EXCEED 10 INCHES. THE CONTRACTOR SHALL SUBMIT TEST
RESULTS OF THE PROPOSED CONCRETE MIXES ALONG WITH THE
MANUFACTURER'S TECHNICAL DATA FOR APPROVAL PRIOR TO
POURING CONCRETE.
*
ALL CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI
301, "SPECIFICATION FOR STRUCTURAL CONCRETE BUILDINGS".
HOT WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 305.
COLD WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 306.
3.
THE CONTRACTOR SHALL ALLOW IN THE BID AN ADDITIONAL ONE (1)
TON OF REINFORCING STEEL TO BE PLACED IN THE FIELD AT THE
DIRECTION OF THE ENGINEER. ANY UNUSED PORTION OF THIS
ALLOWANCE SHALL BE CREDITED TO THE OWNER.
10.
BAR SUPPORTS AND HOLDING BARS SHALL BE PROVIDED FOR ALL
REINFORCING STEEL TO INSURE MINIMUM CONCRETE COVER. BAR
SUPPORTS SHALL BE PLASTIC TIPPED OR STAINLESS STEEL.
9.
UNLESS OTHERWISE NOTED, THE FOLLOWING MINIMUM CONCRETE COVER
SHALL BE PROVIDED FOR REINFORCEMENT:
8.
A) CONCRETE EXPOSED TO EARTH OR WEATHER:
B) CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
#6 THROUGH #I8 BARS -2"
#5 BAR, W31 OR D31 WIRE & SMALLER -1 1/2"
WALLS, ELEVATED SLABS [& JOISTS] -3/4"
BEAMS AND COLUMNS -1 1/2"
B) FOUNDATION CONCRETE (SEE "FOUNDATION NOTES")
ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A-185.5.
ALL REINFORCING STEEL SHALL BE SET AND TIED IN PLACE PRIOR
TO POURING OF CONCRETE, EXCEPT THAT VERTICAL DOWELS FOR
MASONRY WALL REINFORCING MAY BE "FLOATED" IN PLACE. DO NOT
FIELD BEND BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE
UNLESS SPECIFICALLY INDICATED OR APPROVED BY THE ENGINEER.
6.
REINFORCING STEEL, INCLUDING HOOKS AND BENDS, SHALL BE
DETAILED IN ACCORDANCE WITH ACI 3I5. ALL REINFORCING STEEL
INDICATED AS BEING CONTINUOUS (CONT) SHALL BE LAPPED WITH
A TYPE 2 LAP SPLICE UNLESS OTHERWISE NOTED.
7.
ALL REINFORCING STEEL SHALL CONFORM TO ASTM A-615, GRADE 60.
ALL WELDING OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH
AWS D1.4. EPOXY COATED REINFORCING SHALL CONFORM TO ASTM
A-775.
4.
*
WALL THICKNESS HORIZONTAL VERTICAL LOCATION
4" TO 6"#4 @ 16" O.C.#4 @ 18" O.C.CENTERED
8"#4 @ 12" O.C.#4 @ 16" O.C.CENTERED
10"#4 @ 18" O.C.#4 @ 18" O.C.EACH FACE
12"#4 @ 16" O.C.#4 @ 18" O.C.EACH FACE
CAST-IN-PLACE CONCRETE NOTES (CONTINUED):
UNLESS OTHERWISE NOTED, ALL CONCRETE WALLS (OTHER THAN
RETAINING WALLS) SHALL BE REINFORCED AS FOLLOWS:
11.
ALL EDGES OF PERMANENTLY EXPOSED CONCRETE SURFACES SHALL BE
CHAMFERED 3/4" UNLESS OTHERWISE NOTED.
12.
THE CONTRACTOR SHALL PROVIDE THE ENGINEER WITH DOCUMENTA-
TION THAT ALL MATERIALS CONFORM TO THE QUALITY STANDARDS
SPECIFIED IN IBC 2018.
13.
IN ACCORDANCE WITH IBC 2018, SPECIAL INSPECTIONS ARE
REQUIRED FOR THE CONCRETE WORK. THE OWNER WILL HIRE THE
SPECIAL INSPECTOR TO PERFORM ALL REQUIRED SPECIAL INSPECTIONS.
14.
IN ORDER TO AVOID CONCRETE SHRINKAGE CRACKING, PLACE CONCRETE
SLABS IN AN ALTERNATING LANE PATTERN. THE MAXIMUM LENGTH OF
SLAB CAST IN ANY ONE CONTINUOUS POUR SHALL BE LIMITED TO 80 FEET.
15.
FORMWORK SHALL REMAIN IN PLACE UNTIL CONCRETE HAS OBTAINED AT
LEAST 90% OF ITS 28 DAY COMPRESSIVE STRENGTH. THE CONTRACTOR
SHALL PROVIDE ALL SHORING AND RESHORING.
16.
ALL WOOD FRAMING MATERIAL SHALL BE SURFACED DRY AND USED
AT 19% MAXIMUM MOISTURE CONTENT. ALLOWABLE STRESS
REQUIREMENTS OF ALL MATERIAL SHALL BE IN ACCORDANCE ANSI/AWC NDS-18.
ALL STUD AND WALL FRAMING SHALL BE OF THE FOLLOWINGS:
SEE LUMBER GRADE/USE SCHEDULE
"STUD" GRADE MATERIAL IS STRICTLY PROHIBITED FROM USE.
ALL JOIST, RAFTER & MISC. FRAMING SHALL BE PER THE LUMBER GRADE/USE
SCHEDULE . PROVIDE FULL-DEPTH (OR METAL) BRIDGING AT MIDSPAN
AND AT A MAXIMUM SPACING OF 8'-0" O/C IN BETWEEN.
ALL FRAMING EXPOSED TO THE WEATHER OR IN CONTACT WITH
MASONRY OR CONCRETE SHALL BE PRESSURE-TREATED (P.T.) IN ACCORDANCE
WITH THE AMERICAN WOOD PRESERVERS ASSOCIATION SPECIFICATIONS.
WHERE POSSIBLE, ALL CUTS AND HOLES SHOULD BE COMPLETED BEFORE
TREATMENT. CUTS AND HOLES DUE TO ON-SITE FABRICATION SHALL BE
BRUSHED WITH 2 COATS OF COPPER NAPHTHENATE SOLUTION CONTAINING
A MINIMUM OF 2% METALLIC COPPER IN SOLUTION (PER AWPA STD. U1 & M4).
THE CONTRACTOR SHALL CAREFULLY SELECT LUMBER TO BE USED IN
LOADBEARING APPLICATIONS. THE LENGTH OF SPLIT ON THE WIDE
FACE OF 2" NOMINAL LOADBEARING FRAMING SHALL BE LIMITED TO
LESS THAN 1/2 OF THE WIDE FACE DIMENSION. THE LENGTH OF
SPLIT ON THE WIDE FACE OF 3" (NOMINAL) AND THICKER LUMBER
SHALL BE LIMITED TO 1/2 OF THE NARROW FACE DIMENSION.
ALL NAILING NOT OTHERWISE INDICATED SHALL BE IN ACCORDANCE
WITH THE "NAILING SCHEDULE" ON SHEET S00 . NAILING SHALL
NOT BE OVERDRIVEN.
PROVIDE DOUBLE JOISTS UNDER ALL PARTITIONS WHICH RUN PARALLEL
WITH JOISTS AND UNDER ALL CONCENTRATED LOADS FROM FRAMING ABOVE.
PROVIDE HEADER BEAMS OF THE SAME SIZE AS JOISTS OR RAFTERS
TO FRAME AROUND OPENINGS IN THE PLYWOOD DECK UNLESS OTHERWISE
INDICATED.
STRUCTURAL STEEL PLATE CONNECTORS SHALL CONFORM TO ASTM A-36
SPECIFICATIONS AND BE 1/4" THICK UNLESS OTHERWISE INDICATED.
BOLTS CONNECTING WOOD MEMBERS SHALL BE PER ASTM A-307 AND BE
3/4" DIAMETER UNLESS OTHERWISE INDICATED. PROVIDE WASHERS
FOR ALL BOLT HEADS AND NUTS IN CONTACT WITH WOOD SURFACES.
BOLT HOLES SHALL BE CAREFULLY CENTERED AND DRILLED NOT MORE
THAN 1/16" LARGER THAN THE BOLT DIAMETER. BOLTED CONNECTIONS
SHALL BE SNUGGED TIGHT BUT NOT TO THE EXTENT OF CRUSHING
WOOD UNDER WASHERS.
PREFABRICATED METAL JOIST HANGERS, HURRICANE CLIPS, HOLD-DOWN
ANCHORS AND OTHER ACCESSORIES SHALL BE AS MANUFACTURED BY "SIMPSON
STRONG-TIE COMPANY" WWW.STRONGTIE.COM, OR APPROVED EQUAL.
INSTALL ALL ACCESSORIES PER THE MANUFACTURER'S REQUIREMENTS.
ALL STEEL SHALL HAVE A MINIMUM THICKNESS OF 0.04 INCHES (PER
ASTM A446, GRADE A) AND BE GALVANIZED (COATING G60).
HOLES AND NOTCHES DRILLED OR CUT INTO WOOD FRAMING SHALL
NOT EXCEED THE REQUIREMENTS OF IBC 2018, SECTION 2308.4.2.4, 2308.5.9,
2308.5.10 & 2308.7.4.
ALL PLATES, ANCHORS, NAILS, BOLTS, NUTS, WASHERS, AND OTHER
MISCELLANEOUS HARDWARE SHALL BE HOT DIP GALVANIZED.
ALL COLUMNS SHALL EXTEND DOWN THRU THE STRUCTURE TO THE
FOUNDATION. ALL COLUMNS SHALL BE BRACED AT ALL FLOOR LEVELS. COLUMNS
SHALL BE THE SAME WIDTH AS THE MEMBERS THAT THEY ARE SUPPORTING.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
WOOD FRAMING NOTES:
1.LUMBER
ALL WOOD MEMBERS USED FOR LOAD-BEARING PURPOSES, INCLUDING END-JOINTED AND EDGE-GLUED LUMBER,
SHALL BE IDENTIFIED BY THE GRADEMARK OF A LUMBER GRADING OR INSPECTION AGENCY WHICH PARTICIPATES IN AN
ACCREDITATION PROGRAM, SUCH AS THE AMERICAN LUMBER STANDARDS COMMITTEE OR EQUIVALENT. THE GRADEMARK
SHALL INCLUDE AN EASILY DISTINGUISHABLE MARK OR INSIGNIA OF THE GRADING AGENCY WHICH COMPLIES WITH THE
REQUIREMENTS OF U.S. DEPARTMENT OF COMMERCE VOLUNTARY PRODUCT STANDARD 20 PS20) AMERICAN SOFTWOOD
LUMBER STANDARD.
2.GLULAM
GLUE LAMINATED TIMBERS SHALL MEET THE PROVISIONS OF ANSI/AITC A190.1 STRUCTURAL GLUED LAMINATED
TIMBER.
3.PREFABRICATED WOOD I-JOISTS
ASSEMBLIES USING PREFABRICATED WOOD I-JOISTS SHALL MEET THE PROVISIONS OF ASTM D5055 STANDARD
SPECIFICATION FOR ESTABLISHING AND MONITORING STRUCTURAL CAPACITIES OF PREFABRICATED WOOD I-JOISTS , THIS
MANUAL, THE GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S
CODE EVALUATION REPORT.
4.STRUCTURAL COMPOSITE LUMBER
SINGLE MEMBERS OR ASSEMBLIES USING STRUCTURAL COMPOSITE LUMBER SHALL MEET THE PROVISIONS OF ASTM
D5456 STANDARD SPECIFICATION FOR EVALUATIONS OF STRUCTURAL COMPOSITE LUMBER PRODUCTS, THIS MANUAL, THE
GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE
EVALUATION REPORT.
5.PREFABRICATED WOOD TRUSSES
ASSEMBLIES USING PREFABRICATED WOOD TRUSSES SHALL MEET THE PROVISIONS OF THIS MANUAL, THE
GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN ANSI/TPI 1 NATIONAL DESIGN
STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONNECTION, THE TRUSS DESIGN DRAWINGS, OR THE
MANUFACTURER'S CODE EVALUATION REPORT.
6.GYPSUM
GYPSUM MATERIAL USED IN A STRUCTURAL APPLICATION SHALL MEET THE PROVISIONS OF ASTM C 1396/C 1396M,
STANDARD SPECIFICATION FOR GYPSUM BOARD
7.HARDBOARD
HARDBOARD USED IN A STRUCTURAL APPLICATION SHALL MEET THE PROVISIONS OF ANSI/CPA A135.6 HARDBOARD
SIDING.
8.STRUCTURAL PANELS
8.1 ORIENTED-STRAND BOARD (OSB), WAFERBOARD
ORIENTED-STRAND BOARD OR WAFERBOARD USE DIN STRUCTURAL APPLICATIONS SHALL MEET THE
PROVISIONS OF PS2 OR APPLICABLE CODE EVALUATION REPORTS.
8.2 PARTICLEBOARD
PARTICLEBOARD USED IN STRUCTURAL APPLICATIONS SHALL CONFORM TO ANSI A208.1 PARTICEBOARD
STANDARD AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORT.
8.3 FIBERBOARD
FIBERBOARD USED IN STRUCTURAL APPLICATIONS SHALL MEET THE PROVISIONS OF ASTM C208 STANDARD
SPECIFICATION FOR CELLULOSIC FIBER INSULATION BOARD.
8.4 STRUCTURAL PANEL SIDING
STRUCTURAL PANEL SDING USED IN STRUCTURAL APPLICATIONS SHALL MEET THE REQUIREMENTS OF PS1, THE
GOVERNING BUILDING CODE, AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN APPLICABLE CODE EVALUATION
REPORTS.
PLYWOOD SHEATHING SHALL BE AS FOLLOWS: U.N.O.
ROOF SHEATHING SHALL BE 1/2'' CDX INT-APA RATED 32/16, EXP. 1.
B.N.:10d common nails at 4" o.c.
E.N.:10d common nails at 4" o.c.
F.N.:10d common nails at 12" o.c.
FLOOR SHEATHING SHALL BE 3/4'' T & G INT-APA RATED OSB.
B.N.:10d common nails at 4" o.c.
E.N.:10d common nails at 4" o.c.
F.N.:10d common nails at 12" o.c.
1. LAG SCREWS
LAG SCREWS OR LAG BOLTS SHALL COMPLY WITH ANSI/ASME B18.2.1 SQUARE AND HEX BOLTS AND SCREWS (INC
SERIES).
2. TRUSS METAL CONNECTOR PLATES
TRUSS METAL CONNECTOR PLATES SHALL MEET THE REQUIREMENTS OF ANSI/TPI 1, THE GOVERNING BUILDING CODE,
AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE EVALUATION REPORTS.
3. METAL CONNECTORS
WHERE METAL PLATE OR STRAPPING SIZE AND GAGE ARE SPECIFIED, MINIMUM ASTM A653 STANDARD SPECIFICATION
FOR STEEL SHEET, ZINC-COATED (GALVANIZED) OR ZINC-IRON ALLOY-COATED (GALVANNEALED) BY THE HOT-DIP PROCESS,
STRUCTURAL STEEL, GRADE 33 STEEL SHALL BE USED. OTHER METAL CONNECTORS SHALL MEET THE REQUIREMENTS OF
THE GOVERNING BUILDING CODE AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN THE MANUFACTURER'S CODE
EVALUATION REPORTS.
4. NAILS
NAILS SHALL COMPLY WITH ASTM F1667 STANDARD SPECIFICATION FOR DRIVEN FASTENERS: NAILS, SPIKES, AND
STAPLES.
5. PNEUMATIC NAILS AND STAPLES
PNEUMATIC NAILS AND STAPLES SHALL MEET THE REQUIREMENTS OF THE GOVERNING BUILDING CDE AND ANY
ADDITIONAL REQUIREMENTS OF THE GOVERNING BUILDING CODE AND ANY ADDITIONAL REQUIREMENTS AS SET FORTH IN
THE MANUFACTURER'S CODE EVALUATION REPORTS.
WOOD MATETRALS:
FASTENERS AND CONNECTORS:
WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER TO SUPPORT THE
FOLLOWING LOADS:
A. GRAVITY LOADING CASE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
PRE-ENGINEERED WOOD TRUSS NOTES:
WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN AC-
CORDANCE WITH THE APPLICABLE PROVISIONS OF THE LATEST
EDITION OF THE NATIONAL DESIGN SPECIFICATION OF THE NATIONAL
FOREST PRODUCTS ASSOCIATION, THE DESIGN SPECIFICATION FOR
METAL PLATE CONNECTED WOOD TRUSSES OF THE TRUSS PLATE
INSTITUTE AND IBC 2018.
WOOD MATERIALS SHALL BE HEM-FIR, DOUGLAS FIR OR LARCH
AND SHALL BE KILN DRIED AND USED AT 19% MAXIMUM MOISTURE
CONTENT. PROVIDE GRADE NO.2 OR AS REQUIRED TO SATISFY
STRESS REQUIREMENTS.
CONNECTOR PLATES SHALL BE NOT LESS THAN 0.036 INCHES (20
GAUGE) IN COATED THICKNESS, SHALL MEET OR EXCEED ASTM GRADE
A OR HIGHER AND SHALL BE HOT DIPPED GALVANIZED ACCORDING TO
ASTM A-525 (COATING G60). MINIMUM STEEL YIELD STRESS SHALL
BE 33,000 PSI.
TRUSSES SHALL BE FABRICATED IN A PROPERLY EQUIPPED MANUFACT-
URING FACILITY OF A PERMANENT NATURE. TRUSSED SHALL BE
MANUFACTURED BY EXPERIENCED WORKMEN, USING PRECISION CUTTING,
JIGGING AND PRESSING EQUIPMENT UNDER THE REQUIREMENTS IN
QUALITY CONTROL STANDARD QST-88 OF THE TRUSS PLATE INSTITUTE.
SECONDARY BENDING STRESSES IN TRUSS TOP AND BOTTOM CHORDS DUE
TO DEAD, LIVE AND WIND LOADS SHALL BE CONSIDERED IN THE DESIGN.
LOAD DURATION FACTORS SHALL BE PER THE "NATIONAL DESIGN SPECIFI-
CATION FOR WOOD CONSTRUCTION".
WOOD TRUSSES SHALL BE ERECTED IN ACCORDANCE WITH THE TRUSS
MANUFACTURER'S REQUIREMENTS. THIS WORK SHALL BE DONE BY
A QUALIFIED AND EXPERIENCED CONTRACTOR. TRUSS ERECTION
BY AN INEXPERIENCED OR NONQUALIFIED CONTRACTOR CAN RESULT IN
CONSTRUCTION COLLAPSE AND/OR SERIOUS INJURY AND DAMAGE.
THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY AND PERMANENT BRACING
AS REQUIRED FOR SAFE ERECTION AND PERFORMANCE OF THE TRUSSES.
THE GUIDELINES SET FORTH BY THE TRUSS PLATE INSTITUTE
PUBLICATION "H1B-91, COMMENTARY AND RECOMMENDATIONS FOR HANDLING,
INSTALLING AND BRACING METAL PLATE CONNECTED WOOD TRUSSES"
SHALL BE A MINIMUM REQUIREMENT.
TRUSS MEMBERS AND COMPONENTS SHALL NOT BE CUT, NOTCHED,
DRILLED NOR OTHERWISE ALTERED IN ANY WAY WITHOUT THE WRITTEN
APPROVAL OF THE ENGINEER.
SUBMIT COMPLETE SHOP DRAWINGS FOR ALL WOOD TRUSSES SHOWING
MEMBER SIZES, SPECIES, GRADE, MOISTURE CONTENT, SPAN, CAMBER,
DIMENSIONS, CHORD PITCH, BRACING REQUIREMENTS AND LOADINGS.
SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER AND SHALL BEAR
THE SEAL OF A PROFESSIONAL ENGINEER REGISTERED IN WASHINGTON.
SEE THE "SCISSOR TRUSS NOTES" FOR ADDITIONAL REQUIREMENTS.
B. WIND LOADING CASE (PER IBC 2018, SECTION 1609)
SEE 'DESIGN CRITERIA NOTES' FOR WIND COMPONENT CRITERIA
IN S00.1
TOP CHORD LOADING
LIVE LOAD-15 PSF (ON THE HORIZONTAL PROJECTION)
DEAD LOAD-10 PSF (ON THE SURFACE AREA)
-ADDITIONAL 5 PSF AT BUILT-UP FRAMING AREAS
BOTTOM CHORD LOADING
ATTIC LIVE LOAD-20 PSF (PER IBC 2018, SECTION 1607/ TABLE 1607.1)
DEAD LOAD-10 PSF
ALL PLYWOOD CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE
ENGINEERED WOOD ASSOCIATION (APA) SPECIFICATIONS.
ALL ROOF PANEL SHEATHING SHALL BE 5/8" (NOM.) TYPE CDX, EXP. 1
APA RATED SHEATHING. SUITABLE EDGE SUPPORT SHALL BE PROVIDED
BY USE OF PANEL CLIPS OR BLOCKING BETWEEN FRAMING. UNLESS
OTHERWISE NOTED CONNECT ROOF SHEATHING WITH 10d COMMON NAILS
AT 4" O/C AT SUPPORTED PANEL EDGES (E.N.) AND 12" O/C AT INTERMEDIATE
SUPPORTS (F.N.).
ALL FLOOR SHEATHING SHALL BE 3/4" (NOM.) APA RATED STURD-1-FLOOR,
EXP. 1, WITH TONGUE AND GROOVE EDGE. UNLESS OTHERWISE NOTED
CONNECT FLOOR SHEATHING WITH 10d COMMON NAILS SPACED 4" O/C AT
SUPPORTED EDGES AND 12" O/C AT INTERMEDIATE SUPPORTS. FIELD-
GLUE USING ADHESIVES MEETING APA SPECIFICATION AFG-01, APPLIED
IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
ALL WALL PANEL SHEATHING SHALL BE 1/2" (NOM.) TYPE CDX, EXP. 1
APA RATED SHEATHING. UNLESS OTHERWISE INDICATED, CONNECT
WALL SHEATHING WITH 10d COMMON NAILS SPACED 6" O/C AT SUP-
PORTED PANEL EDGES AND 12" O/C AT INTERMEDIATE SUPPORTS.
INSTALL ALL PLYWOOD SHEATHING WITH THE LONG DIMENSION OF THE
PANEL ACROSS SUPPORTS AND WITH PANEL CONTINUOUS OVER TWO OR
MORE SPANS. STAGGER PANEL END JOINTS. ALLOW 1/8" SPACING
AT PANEL ENDS AND EDGES UNLESS OTHERWISE RECOMMENDED BY THE
SHEATHING MANUFACTURER.
ALL NAILING SHALL BE CAREFULLY DRIVEN AND NOT OVERDRIVEN. THE
USE OF STAPLES AND PNUEMATIC NAIL GUNS ARE PROHIBITED FROM USE.
ALL EXT. WALLS SHALL BE SHEATHED ON BOTH FACES WITH GYP-BOARD
SHEATHING (SEE ARCH. DWGS. FOR THICKNESSES) AND CONNECTED
WITH 5d COOLER NAILS SPACED 7" O/C AT SUPPORTED PANEL EDGES
AND INTERMEDIATE SUPPORTS.
PROVIDE 2X BLOCKING AT UNSUPPORTED PANEL EDGES AS FOLLOWS:
ROOFS AND FLOORS-ONLY WHERE INDICATED ON PLAN
WALLS-PER THE SHEARWALL SCHEDULE ON SHEET S00.1
1.
2.
3.
4.
5.
6.
7.
8.
PLYWOOD/GYPBOARD SHEATHING NOTES:
PREFABRICATED WOOD I-JOISTS SHALL BE DESIGNED AND FURNISHED IN
ACCORDANCE WITH A CURRENT CODE-ACCEPTED EVALUATION REPORT. STRUCTURAL
CAPACITIES AND DESIGN PROVISIONS SHALL BE ESTABLISHED AND MONITORED
IN ACCORDANCE WITH ASTM D 5055.
WOOD JOISTS SHALL BE DESIGNED BY THE MANUFACTURER TO SUPPORT THE
LOADS INDICATED PER THE JOIST LOADING DIAGRAMS. UNLESS OTHERWISE
INDICATED, JOISTS SHALL BE DESIGNED FOR THE FOLLOWING:
TOP CHORD LOADING
LIVE LOAD-40 PSF
DEAD LOAD-15 PSF
BOTTOM CHORD LOADING
DEAD LOAD-5 PSF
WIND LOAD-35 PSF NET UPLIFT PRESSURE (ROOF JOISTS ONLY)
WOOD I-JOISTS SHALL BE ERECTED IN ACCORDANCE WITH THE MANUFACTURER'S
REQUIREMENTS. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY AND
PERMANENT BRACING AS REQUIRED FOR SAFE ERECTION AND PERFORMANCE
OF THE JOISTS.
WOOD I-JOISTS SHALL NOT BE CUT, NOTCHED, COPED, DRILLED NOR OTHERWISE
ALTERED IN ANY WAY UNLESS SPECIFICALLY CONDUCTED IN ACCORDANCE
WITH THE MANUFACTURER'S WRITTEN REQUIREMENTS. DO NOT CUT FLANGES.
WOOD I-JOIST SHALL BE PRODUCED BY A CODE ACCEPTED FABRICATOR WITH
A MINIMUM OF FIVE (5) YEARS EXPERIENCE PRODUCING PREFABRICATED
WOOD I-JOISTS. QUALITY CONTROL SHALL BE AUDITED BY AN AGENCY
ACCEPTED BY THE "BUILDING OFFICIALS & CODE ADMINISTRATORS, INC.".
WEB PANELS MUST BE JOINED WITH A MACHINED AND GLUED VEE JOINT TO FROM
A CONTINUOUS MEMBER. ALL JOINTS SHALL BE GLUED USING AN EXTERIOR TYPE
ADHESIVE PER ASTM D 2559.
WOOD I-JOISTS SHALL BE STORED IN BUNDLES IN AN UPRIGHT POSITION AND
AWAY FROM GROUND CONTACT. ANY DAMAGE TO JOISTS SHALL BE BROUGHT TO
THE IMMEDIATE ATTENTION OF THE JOIST SUPPLIER. FIELD REPAIR OR MOD-
IFICATION OF JOISTS MUST NOT BE MADE WITHOUT THE WRITTEN APPROVAL BY
THE SUPPLIER, EXCEPT FOR TRIMMING TO CORRECT LENGTH.
WOOD I-JOISTS SHALL BE CAREFULLY HANDLED TO PREVENT DAMAGE AND DIS-
TORTION. EACH JOIST SHALL BE ANCHORED AND BRACED, AS IT IS ERECTED,
USING BLOCKING PANELS AND ANCHORAGE INDICATED (AND PER THE SUPPLIER'S
REQUIREMENTS). ERECTOR SHALL PROVIDE SUPPLEMENTAL LATERAL BRACING OF
THE TOP FLANGE UNTIL SHEATHING IS PROPERLY NAILED.
ALL ROOF JOISTS SHALL BE POSITIONED WITH THE NATURAL CAMBER TURNED UP.
1.
2.
3.
4.
5.
6.
7.
8.
9.
PREFABRICATED WOOD JOIST NOTES:
FASTENING
(3) 0.131"X3" TOENAILS
(3) 0.131"X3" TOENAILS EA. END
(2) 0.131"X2.5" FACE NAIL
(3) 0.131"X2.5" FACE NAIL
(2) 0.161"X3.5" BLIND & FACE NAIL
0.131"X3" AT 8" O.C. TYP. FACE NAIL
(4) 0.131"X3" AT 16" O.C. FACE NAIL
(3) 0.131"X3" END NAIL
(4) 0.131"X3" TOENAIL
(3) 0.131"X3" END NAIL
0.131"X3" AT 8" O.C. FACE NAIL
0.131"X3" AT 8" O.C. TYP. FACE NAIL
(20) 0.131"X3" FACE NAILS
(3) 0.131"X3" TOENAILS
0.131"X3" AT 6" O.C. TOENAIL
(3) 0.131"X3" FACE NAIL
0.131"X3" AT 12" FACE NAIL EA. EDGE
(5) 0.131"X3" TOENAIL
(4) 0.131"X3" TOENAILS
(4) 0.131"X3" FACE NAIL
(4) 0.131"X3" FACE NAIL
(3) 0.131"X3" TOENAIL
(2) 0.131"X3" FACE NAIL
(2) 0.131"X3" FACE NAIL
(3) 0.131"X3" FACE NAIL
(3) 0.131"X3" AT 16" O.C. FACE NAIL
0.131"X3" AT 12" FACE NAIL EA. SIDES
STAGGERED
ROUGH FRAMING NAILING SCHEDULE (IN LIEU OF IBC TABLE 2304.10.1)
ROUGH FRAMING NAILING SCHEDULE
CONNECTION
1. JOIST TO SILL OR GIRDER
2. BRIDGING TO JOIST, RAFTER OR TRUSS
3. 1X6 OR LESS SUBFLR. TO JST.
4. WIDER THAN 1X6 SUBFLR. TO JST.
5. 2" SUBFLOOR TO JST./GIRDER
6. SOLE PLATE TO JST. OR BLKG.
SOLE PLATE AT BRACED WALL PANEL
7. TOP PLATE TO STUD
8. STUD TO SOLE PLATE
(OR)
9. DOUBLE STUDS
10. DOUBLE TOP PLATES
DOUBLE TOP PLATE LAP SPLICE
11. JOIST/RAFTER BLKG. TO PLATE
12. RIM JOIST TO TOP PLATE
13. TOP PLATE LAP INTERSECTIONS
14. DOUBLE 2X JOIST/HEADER
15. CEILING JOISTS TO PLATE
16. CONTINUOUS HEADER TO STUD
17. CEILING JST. LAP AT PARTITIONS
18. CEILING JST. TO PARALLEL RAFTER
19. RAFTER TO PLATE
20. 1X BRACE TO EA. STUD & PLATE
21. 1X8 OR LESS SHTG. TO EA. BRG.
22. WIDER THAN 1X8 SHTG. TO BRG.
23. BUILT-UP CORNER STUDS
24. BUILT-UP GIRDERS AND BEAMS
PROVIDE SPECIAL INSPECTION, SPECIAL TESTING, REPORTING
AND COMPLIANCE PROCEDURES ACCORDING TO IBC 2018 CHAPTER 17.
SPECIAL INSPECTOR QUALIFICATIONS: DEMONSTRATE
COMPETENCE. TO THE SATISFACTION OF THE BUILDING OFFICIAL,
FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION
OR OPERATION IN QUESTION. PRIOR TO THE BEGINNING OF
CONSTRUCTION. REVIEW THE SPECIAL INSPECTION
REQUIREMENTS WITH THE ARCHITECT, ENGINEER, BUILDING
OFFICIAL, GENERAL CONTRACTOR AND SPECIAL INSPECTORS.
DUTIES OF THE SPECIAL INSPECTOR INCLUDE. BUT ARE NOT
LIMITED TO:
OBSERVE THE WORK FOR CONFORMANCE WITH THE
APPROVED PERMIT DRAWINGS AND SPECIFICATIONS. BRING
DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE
CONTRACTOR FOR BUILDING OFFICIAL.
FURNISH INSPECTION REPORTS FOR EACH INSPECTION TO
THE BUILDING OFFICIAL, ARCHITECT, ENGINEER, GENERAL
CONTRACTOR AND OWNER IN A TIMELY MANNER.
SUBMIT A FINAL REPORT STATING WHETHER THE WORK
REQUIRING SPECIAL INSPECTION WAS INSPECTED, AND WHETHER
THE WORK IS IN CONFORMANCE WITH THE APPROVED PERMIT
DRAWINGS AND SPECIFICATIONS.
DUTIES OF THE CONTRACTOR INCLUDE, BUT ARE NOT LIMITED
TO:
NOTIFY SPECIAL INSPECTOR THAT WORK IS READY FOR
INSPECTION AT LEAST 24 HOURS BEFORE THE INSPECTION IS
REQUIRED.
MAINTAIN ACCESS TO WORK REQUIRING SPECIAL INSPECTION
UNTIL IT HAS BEEN OBSERVED AND INDICATED TO BE IN
CONFORMANCE BY THE SPECIAL INSPECTOR AND APPROVED BY
THE BUILDING OFFICIAL.
PROVIDE THE SPECIAL INSPECTOR WITH ACCESS TO
APPROVED PERMIT DRAWINGS AND SPECIFICATIONS AT THE JOB
SITE.
MAINTAIN JOB-SITE COPIES OF ALL REPORTS SUBMITTED BY
THE SPECIAL INSPECTOR.
1.
2.
A.
B.
C.
3.
A.
B.
C.
D.
INSPECTION NOTES:
SOILS:
GRADING, EXCAVATION, AND FILL
DRILLED PIERS
CONCRETE:
PLACEMENT OF REINFORCING STEEL
BOLTS CAST IN CONCRETE
PLACING OF CONCRETE OVER 2,500 PSI
SPECIAL CASES:
SHEAR WALL NAILING
WOOD DIAPHRAGMS
ADHESIVE ANCHOR INSTALLATION
EXPANSION BOLT INSTALLATION
HOLD DOWNS AND STRAPS
REF. PROJECT SPECIFICATIONS
REF. PROJECT SPECIFICATIONS
PER ICBO EVALUATION REPORT
PER ICBO EVALUATION REPORT
PER FOOTNOTE #5
X
PERIODIC CONTINUOUS COMMENTS
SPECIAL INSPECTION PROGRAM
ESTABLISHED PER CHAPTER 17 OF THE 2018 IBC, UNLESS NOTED OTHERWISE
ALL SPECIAL INSPECTIONS SHALL BE CONTINUOUS, UNLESS NOTED OTHERWISE
TYPES OF WORK
SPECIES & SIZE GRADE
LUMBER GRADE/USE SCHEDULE
HEM-FIR (HF.)
2X, 3X, 4" WIDE, 6" & WIDER
NO.2
USE/LOCATION
WALL
STUDS/BLOCKS
WALL PLATES
LEDGER BOARDS
BEAMS & POSTS
Fb (PSI)Fv (PSI)Fcp (PSI)Fc (PSI)E (PSI)
HEM-FIR (HF.)
2X4, 3X4, 2X6, 3X6
NO.2
JOISTS HEM-FIR (HF.)
2X, 3X
NO.2
DOUGLAS FOR-LARCH (DF.)
2X, 3X
NO.2
LEDGER BOARDS DOUGLAS FOR-LARCH (DF.)
4X
NO.1
DOUGLAS FOR-LARCH (DF.)
4X
NO.2
BEAMS & POSTS DOUGLAS FOR-LARCH (DF.)
6X
NO.1
850
850
850
900
1000
900
1200 170 625 1000 1.6E6
180 625 1350 1.6E6
150 405 1300 1.3E6
180 625 1500 1.7E6
180 625 1350 1.6E6
150 405 1300 1.3E6
150 405 1300 1.3E6
DIAMETER LENGTH
NAIL SIZE SCHEDUAL
0.131"2-1/2"
NAILS SIZE
8d COMMON NAIL
10d COMMON NAIL
12d COMMON NAIL
16d COMMON NAIL
0.148"
0.148"
0.162"
3.0"
3-1/4"
3-1/2"
COMBINATION
SYMBOL/SPECIES CAMBER
GLULAM BEAMS SIZE SCHEDUAL
24F-V4 DF/DF STANDARD
USE
SIMPLE SPAN BEAM
CONTINUOUS BEAM
CANTILEVER BEAM
ZERO24F-V8 DF/DF
24F-V8 DF/DF ZERO
WALL TYPE LOCATION PLATE SIZE STUD SIZE &
SPACING
BEARING WALL STUD SCHEDUAL
EXTERIOR
CRAWL SPACE
INTERIOR
TYPICAL U.N.O.
PER PLAN
TYPICAL
TYPICAL U.N.O.
PER PLAN
2X4
2X4
2X6 2X6 @ 16" O/C
2X4 @ 16" O/C
2X4 @ 16" O/C
MARK
BW1
BW2
BW2
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject AddressAs indicated
Project Number
Issue Date
Author
Checker
GENERAL
STRUCTURAL
SPECIFICATIONS
& NOTESSINGH RESIDENCERAM S.S00 34XX TALBOT RD RENTON WA04/27/2022
LIST OF ABBREVIATIONS;
ADD`L ADDITIONAL
APPROX.APPROXIMATE
ARCH. ARCHITECTURAL DRAWINGS
ASD ALLOWABLE STRESS DESIGN
B.F.BOTTOM FACE
B.M.BENCHMARK
B.N.BOUNDARY NAILING
B.O.B.BOTTOM OF BOREHOLE
B.O.T.P. BOTTOM OF TEST PIT
BOTT. BOTTOM
C CENTIGRADE
C.C.CENTER TO CENTER
CFM CUBIC FEET PER MINUTE
C.I.CAST IRON
C.J.CONSTRUCTION JOINT
CLR. CLEAR
CMP CORRUGATED METAL PIPE
CONC.CONCRETE
CONT.CONTINUOUS
CT.J.CONTRACTION JOINT
DEG.DEGREE
DIA. DIAMETER
DIAG.DIAGONAL
DWL DOWEL
E EAST, EASTING
EA.EACH
E.F.EACH FACE
E.N.EDGE NAILING
E.J.EXPANSION JOINT
EL.ELEVATION
E.W.EACH WAY
EXIST.EXISTING F FAHRENHEIT
F.F.FAR FACE
FIG.FIGURE
F.N.FIELD NAILING
FT.FEET
FTG FOOTING
FIN.FINISH
GA.GAGE
GAL GALLON
GALV.GALVANIZED
GR.GRADE
G.L.GRADE LEVEL
GPM GALLONS PER MINUTE
H.P. HIGH POINT, HORSE POWER
HR HOUR
HORIZ. HORIZONTAL
HT. HEIGHT
I.D.INSIDE DIAMETER
I.F.INSIDE FACE
INV.INVERT
IN.INCH
JST JOIST
JT.JOINT
KIPS KILOPOUNDS
LB.POUND
L.P.LOW POINT
LG.LONG LONG. LONGITUDINAL
MAX.MAXIMUM
MIN.MINIMUM
M.H.MANHOLE
MFR.MANUFACTURER
NGVD NATIONAL GEODETIC VERTICAL DATUM
N NORTH, NORTHING
N.I.A.NOT IN CONTRACT
N.T.S.NOT TO SCALE
N.F.NEAR FACE
O/C ON CENTERS
O.D.OUTSIDE DIAMETER
O.F.OUTSIDE FACE
O.H.OVER HANG
O.W.OUTLET WORKS
P.C.POINT OF CURVATURE
P.T.PRESSURE TREATED
P.D.PLAIN DOWEL
P.I.POINT OF INTERSECTION
PL.PLATE PREEAB. PREFABRICATED
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
PVC POLYVINYL-CHLORIDE
R RADIUS
RCC ROLLER COMPACTED CONCRETE
RCP REINFORCED CONCRETE PIPE
REINF.REINFORCEMENT
REQD.REQUIRED
REV.REVISION
S SOUTH
SCH.SCHEDULE
SH.SHEET
S.S.STAINLESS STEEL
SECT.SECTION
SIM.SIMILAR
SIMPS. SIMPSON STRONG TIES
S.O.G. SLAB ON GRADE
SQ.SQUARE
SPEC. SPECIFICATIONS
STA.STATION
SYM.SYMMETRICAL
STD.STANDARD
T&B TOP AND BOTTOM
T.F.TOP FACE
THK.THICKNESS
TRANS. TRANSVERSE
TOPO.TOPOGRAPHY
TYP.TYPICAL
T.O.W.TOP OF WALL
T.O.F.TOP OF FOOTING
U.N.O. UNLESS NOTED OTHERWISE
VERT. VERTICAL
W WEST
W/ WITH
W/O WITHOUT
W.S.WATERSTOP
WSP WOOD STRUCTURAL PANEL
LEGEND
XXX
FOUNDATION
ELEVATION
X.XX"DROP OR STEP
FX-X SPREAD FOOTING NUMBER PER SCHEDULE
WFX-X WALL FOOTING NUMBER PER SCHEDULE
XXX WOOD POST OR TRIMMER
DIRECTION OF MEMBERS PER SCHEDULE X
MEMBERS DISTRIBUTION
XXX HOLD-DOWN PER SCHEDULE
X'-X"
WX SHEAR WALL LENGTH AND NUMBER
REFER TO SHEAR WALL SCHEDULE FOR SPEC.
X
S-X
DETAIL NUMBER
SHEET NUMBER
X
BEAM NUMBER, REFER TO CALCULATION
REPORT AND BEAM SCHEDULE
KEY NOTE NUMBER X
BEARING WALL HIGHLIGHTED IN GRAY,
OR CALLED OUT
A.B. PER SCH.
BRACED WALL
PER SHEAR WALL SCH.
A.B. PER SCH.
12" FROM CORNERS
X'-X"
WX
KEY NOTES
BLOCKED ROOF DIAPHRAGM W/ 10d @ 4" O/C B.N., 4" O/C E.N. & 12" O/C
FIELD 1
2
BLOCKED FLOOR DIAPHRAGM W/ 10d @ 4" O/C B.N., 4" O/C E.N. & 12" O/C
FIELD
3 HEADER, SEE HEADER SCHEDULE
BLOCKING AND CONNECTION SHALL BE PROVIDED AT PANEL EDGES
PERPENDICULAR TO FLOOR FRAMING MEMBERS IN THE FIRST TWO BAYS @ 48"
O/C MAX4
5 HOLD-DOWN ABOVE
HOLD-DOWN
PER SCH.
XXX
XXX
HOLD-DOWN POST
PER SCH.
BEAM/HEADER
JOIST/RAFTER HANGER OR BEAM BRACKET
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject AddressAs indicated
Project Number
Issue Date
Author
Checker
SCH. & DESIGN
INFO.SINGH RESIDENCERAM S.S00.1 34XX TALBOT RD RENTON WAwww.struware.c
CODE SUMMARY
Code:International Building Code 2018
Live Loads:
Roof 0 to 200 sf: 20 psf
200 to 600 sf: 24 - 0.02Area, but not less than 12 psf
over 600 sf: 12 psf
Typical Floor 30 psf
Partitions 15 psf
All other residential areas except balconies & decks40 psf
Dead Loads:
Floor 15.0 psf
Roof 15.0 psf
Wind Design Data:
Ultimate Design Wind Speed 110 mph
Nominal Design Wind Speed 85.21 mph
Risk Category II
Mean Roof Ht (h)25.0 ft
Exposure Category B
Enclosure Classif.Enclosed Building
Internal pressure Coef.+/-0.18
Directionality (Kd)0.85
Roof Snow Loads:
Design Uniform Roof Snow load =15.4 psf
Flat Roof Snow Load Pf =15.4 psf
Balanced Snow Load Ps =15.4 psf
Ground Snow Load Pg =20.0 psf
Importance Factor I =1.00
Snow Exposure Factor Ce =1.00
Thermal Factor Ct =1.10
Sloped-roof Factor Cs =1.00
Drift Surcharge load Pd =
Width of Snow Drift w =
Earthquake Design Data:
Risk Category =II
Importance Factor I =1.00
Mapped spectral response accelerations Ss =140.50
S1 =52.30
Site Class =D
Spectral Response Coef.Sds =0.937
Sd1 =0.620
Seismic Design Category =D
Basic Structural System =Bearing Wall Systems
Seismic Resisting System =Light frame (wood) walls with structural wood shear panels
Design Base Shear V =0.144W
Seismic Response Coef.Cs =0.144
Response Modification Factor R =6.5
Analysis Procedure = Equivalent Lateral-Force Analysis
Roof Surface Pressure (psf)
Area 10 sf 20 sf 100 sf 200 sf
Negative Zone 1 -27.3 -27.3 -21.8 -21.8
Negative Zone 2e -36.5 -33.5 -26.6 -23.6
Negative Zone 2r -47.6 -42.9 -32.0 -27.3
Negative Zone 3 -50.4 -45.4 -33.8 -28.8
Positive All Zones 16.2 16.0 16.0 16.0
Overhang Zone 1 -33.2 -33.2 -36.9 -36.9
Overhang Zone 2e -42.4 -41.6 -39.6 -38.7
Overhang Zone 2r -53.5 -50.9 -45.0 -42.4
Overhang Zone 3 -67.3 -59.8 -42.3 -34.7
Overhang soffit pressure equals adj wall pressure (which includes internal pressure of 3.3 psf)
Parapet Solid Parapet Pressure (psf)
Area 10 sf 20 sf 50 sf 100 sf 200 sf 500 sf
CASE A: Zone 2e : 0.0 0.0 0.0 0.0 0.0 0.0
Zone 2r : 0.0 0.0 0.0 0.0 0.0 0.0
Zone 3 : 0.0 0.0 0.0 0.0 0.0 0.0
CASE B : Interior zone : 0.0 0.0 0.0 0.0 0.0 0.0
Corner zone : 0.0 0.0 0.0 0.0 0.0 0.0
Wall Surface Pressure (psf)
Area 10 sf 100 sf 200 sf 500 sf
Negative Zone 4 -23.6 -20.4 -19.4 -18.1
Negative Zone 5 -29.1 -22.6 -20.7 -18.1
Positive Zone 4 & 5 21.8 18.5 17.5 16.2
04/27/2022
4" S.O.G.
W/ WWF 6X6 -10/10
OR #3 @ 12" O/C E.W.
U.N.O BY SOIL REPORTFINISHED GRADE
5% SLOPE CLR.0' - 3"PER PLAN
W H PER PLAN2X P.T. SILL PL.
5/8"X10" A.B. PER SCH.
W/ MIN. 3X3X0.229" WASHER PL.
7"EMBED IN CONC.
MAX. 48" O/C
12" FROM EACH CORNER
WSP
PER SCH.
2X STUD @ 16" O/C U.N.O.
WATERPROF
BY OTHERS
NOTE;
1. SEE FOUNDATION NOTES FOR ADD`L REQUIREMENTS.
2. SEE NAILING SCH. FOR MORE INFO.
3. SEE SHEAR WALL SCH. FOR WSP THICKNESS AND A.B. DETAILS.
CONT. REBARS PER SCH.
min.2-#4MIN.0' - 8"4" PVC PERF. PIPE
W/ 2% MIN. SEE NOTES
4" MIN WELL GRADED GRAVEL
OVER COMPACTED SOIL PER
SOIL REPORT
6 MIL VAPOR RETARDER
CLEAN COMP`ED FILL
18" MIN. OR BELOW FROST DEPTH
1
2
UNDISTURBED, FIRM
NATURAL SOIL OR
COMPACTED SOIL PER SOIL
REPORT
TYP.
0' - 3"
18" MIN. OR BELOW FROST LINE
PER PLAN
2X6 STUDS @ 16" O/C U.N.O.
8" CONC. STEM WALL
2X8 P.T. SILL PL.
4" S.O.G.
W/ WWF 6X6 -10/10
OR #3 @ 12" O/C E.W.
U.N.O BY SOIL REPORT
CONC. FTG. PER SCH.
1" ISOLATION
NOTE;
1-SEE FOUNDATION NOTES FOR ADD`L REQUIREMENTS.
2-SEE NAILING SCH. & SHEAR WALL SHC. FOR MORE INFO.
3-EXT. & INTER. SHEATHING NOT SHOWN FOR CLARITY.
4-SEE SOIL REPORT FOR COMPACTION REQUIREMENTS.PER PLANTYP.0' - 3"5/8" X10" A.B. W/ 3"X3"X0.229" PL.
MIN. 7" EMBED IN CONC.
@48" O/C MAX. SEE SHEAR WALL SCH.
W/12" FROM EACH CORNER
5% MIN, FINAL
GRADE SLOPE
GARAGE WALL
DOWEL PER PLAN W/ 90
DEG STD. HOOK INTO FTG
WATERPROOF
DESIGN BY OTHERS
GEO-TEXTILE
WASHED GRAVEL OR
CRUSHED ROCK
4" PVC PERFORATED
PIPE W/ 2% SLOPE 1' - 0"T.O.W.
UNDISTURBED, FIRM NATURAL
SOIL OR COMPACTED SOIL PER
SOIL REPORT
4" MIN WELL GRADED GRAVEL
OVER COMPACTED SOIL PER
SOIL REPORT
CONT. REBARS
PER SCH.
TRANS. REBARS
PER SCH.
TYP.
0' - 3"
PER PLAN
2X6 STUDS @ 16" O/C U.N.O.
8" CONC. STEM WALL
2X8 P.T. SILL PL.
4" S.O.G.
W/ WWF 6X6 -10/10
OR #3 @ 12" O/C E.W.
U.N.O BY SOIL REPORT
CONC. FTG. PER SCH.
1" ISOLATION
PER PLANTYP.0' - 3"5/8" X10" A.B. W/ 3"X3"X0.229" PL.
MIN. 7" EMBED IN CONC.
@48" O/C MAX. SEE SHEAR WALL SCH.
W/12" FROM EACH CORNER
5% MIN, FINAL
GRADE SLOPE
EXTERIOR WALL
DOWEL PER PLAN W/ 90
DEG STD. HOOK INTO FTG
WATERPROOF
DESIGN BY OTHERS
GEO-TEXTILE
WASHED GRAVEL OR
CRUSHED ROCK
4" PVC PERFORATED
PIPE W/ 2% SLOPE
UNDISTURBED, FIRM NATURAL SOIL
OR COMPACTED SOIL PER SOIL REPORTMIN.0' - 8"18" MIN. OR BELOW FROST LINE
T.O.W.
4" MIN WELL GRADED GRAVEL
OVER COMPACTED SOIL PER
SOIL REPORT
CONT. REBARS
PER SCH.
TRANS. REBARS
PER SCH.
NOTE;
1-SEE FOUNDATION NOTES FOR ADD`L REQUIREMENTS.
2-SEE NAILING SCH. & SHEAR WALL SHC. FOR MORE INFO.
3-EXT. & INTER. SHEATHING NOT SHOWN FOR CLARITY.
4-SEE SOIL REPORT FOR COMPACTION REQUIREMENTS.
VERTICAL REINFORCEMENT
NOT SHOWN
VERTICAL REINFORCEMENT NOT
SHOWN
VERTICAL REINFORCEMENT
NOT SHOWN
STANDARD 90-DEGREE HOOK
UNO (ALTERNATE HOOKS)
STANDARD 90-DEGREE HOOK
UNO (ALTERNATE HOOKS)
DOWEL
CORNER BAR48 bd/24" MIN.48 bd/24" MIN.48 bd/ 24" MIN.VERTICAL REINFORCEMENT
NOT SHOWN
48 bd/ 24" MIN.PLAN
OPTION #1
PLAN
OPTION #1
PLAN
OPTION #2
PLAN
OPTION #20" TYPNOTE:
UNLESS OTHERWISE INDICATED, THE CONTRACTOR HAS THE OPTION OF REINFORCING
CORNERS IN ACCORDANCE WITH OPTION #1 OR OPTION #2
SINGLE LAYER HORIZONTAL WALL REINFORCEMENT AT
INTERSECTIONS
NOTE:
UNLESS OTHERWISE INDICATED, THE CONTRACTOR HAS THE OPTION OF REINFORCING
CORNERS IN ACCORDANCE WITH OPTION #1 OR OPTION #2
SINGLE LAYER HORIZONTAL WALL REINFORCEMENT AT CORNERS
2X INTERIOR
BEARING WALL PER PLAN
2X P.T. BOTTOM PL.4" MIN. S.O.G.
WWF 6X6-10/10
OR; #3 @ 12" O/C U.N.O.
PER SOIL REPORT
UNDISTURBED, FIRM
NATURAL SOIL OR
COMPACTED SOIL
PER SOIL REPORT
NOTE; SHEATHING NOT SHOWN
FOR CLARITY
1/2" X10" A.B. W/ 3"X3"X0.229"
PL. MIN. 7" EMBED IN CONC.
@48" O/C MAX.W/12" FROM
EACH CORNER
WIDTH PER SCH.
UNFORMED SURFACE
OR BELOW FROST LINEMIN.1' - 6"2-#4 CONT. BARS
S.O.G. LEVEL
1
2
1
2
S.O.G. LEVEL
CONC. SPREAD FTG
PER PLAN
SEE SH.
WOOD POST PER PLANCOL. BASE
SIMS. CB66
W/ 2-5/8" BOLTS
8" CLEAN WELL-GRADED
GRAVEL & SAND
ON COMPACTED SOIL PER
SOIL REPORT
REINF. STEEL
PER PLAN
TYP.CLR.0' - 3"4" S.O.G.
1.POST PER PLAN
2.SILL PLATE
3.ANCHOR BOLT. SEE PLANS
FOR SIZE AND SPACING
4.3" CLEARANCE. TYPICAL
5.ADD #4 BAR BENT DOWN
INTO FOOTING AT CURB
6.7'-0" TO THE BOTTOM OF
THE HEADER (U.N.O.).
7.TOP OF SLAB AT GARAGE
8.TYPICAL CONT. #4 TOP AND
BOTTOM (U.N.O.)
9.6'-6" TO THE BOTTOM
OF THE HEADER
10.7" CURB MIN.
11.1'-10" MIN.
NOTES:
4x4 POSTS CAN BE REPLACED WITH 2-2x4
AS LONG AS NAILS ARE MAINTAINED WITH
MIN. EDGE DISTANCE AS REQUIRED BY THE
MANF. SPEC. & S.W. EDGE NAILS STAGG
ON BOTH STUDS.
11
231
10
8
6
7
5
9
4
SILL BOLD REQUIREMENTS
1. PROVIDE A MINIMUM SILL BOLT EMBEDMENT OF 7" BELOW FINISH FLOOR OR TOP OF CURB.
2. PROVIDE AN ADDITIONAL SILL BOLT 7 INCHES FROM EACH END OF EACH PIECE OF SILL PLATE.
3. WHERE SILL PLATES ARE BORED OR NOTCHED IN EXCESS OF 1/3 OF THE SILL PLATE WIDTH, PROVIDE ADDITIONAL SILL
BOLTS 6 INCHES EACH SIDE OF BORE OR NOTCH.
4. SET ALL SILL BOLTS WITH A SETTING TEMPLATE BEFORE PLACING CONCRETE. STABBING OR PUSHING OF SILL BOLTS
INTO WET CONCRETE IS EXPRESSLY PROHIBITED.
5. PROVIDE A MINIMUM SILL BOLT PROJECTINO ABOVE THE CONCRETE AS SHOWN ON DETAIL C.
2x NAILER, TYP.
U.N.O.
BUTT END OR END OF
SILL PLATE
BORE OR NOTCH
TOP OF CONC.
TYPICAL PLATE ELEVATION A PLAN VIEW B
MINIMUM SILL BOLT PROJECTION C
0' - 6"
3" MIN. WHERE
DRYPACK OCCURS
0' - 6"0' - 6""W"2X6 STUD @ 16" O/C
ELEVATION
6-10d EA. SIDE
SILL PL.2X FILLER PL.
2X BRIDGE PL.
2X6 STUD @ 16" O/C
ELEVATION
2X SOLICE PL.
A.B. PER S.W. SHC.
A.B. PER S.W. SHC.
"a""b"
SPLICE LINE
PLAN VIEW
SPLICE LINE
6-10d EA. SIDE OF SPLICE
OPTIONAL SILL PLATE SPLICE
NOTE; THIS DETAIL REQUIRED WHEN EITHER a OR b IS GREATER THAN 9".
WALL FOOTING SCHEDULE
MARK WIDTH THICK.CONT.
REBAR NOTES
WF1-0 2-#4
TRANS.
REBAR
WF1-2
WF1-4
WF1-6
1'-0"
1'-2"
1'-4"
1'-6"
0'-8"
0'-8"
0'-8"
0'-8"
2-#4
2-#4
3-#4 #4 @ 9" O/C
STEM WALL
THICKNESS
8", 2,500 PSI.
STEM WALL REBARS
#4 VERT@ 18" O/C W/ STD. 90 HOOK INTO
FTG & #4 HORIZ. @ 16" O/C TYP.
#4 VERT@ 18" O/C W/ STD. 90 HOOK INTO
FTG & #4 HORIZ. @ 16" O/C TYP.
#4 VERT@ 16" O/C W/ STD. 90 HOOK INTO
FTG & #4 HORIZ. @ 14" O/C TYP.
#4 VERT@ 16" O/C W/ STD. 90 HOOK INTO
FTG & #4 HORIZ. @ 14" O/C TYP.
8", 2,500 PSI.
8", 2,500 PSI.
8", 2,500 PSI.
SPREAD FOOTING SCHEDULE
MARK SIZE THICK.
LONG.
D1-6 --
TRANS.
D2-0
F2-0
F2-6
1'-6" DIA.
2'-0" DIA.
2'-6"X2'-6"
2'-0"X2'-0"
24"
36"
12"
--
3-#4 TOP & BOTT.
3-#4 TOP & BOTT.
F3-0
F3-6
F4-0
F4-6
3'-0"X3'-0"
4'-0"X4'-0"
4'-6"X4'-6"
3'-6"X3'-6"
12"
12"
12"
12"
12"
--
--
3-#4 TOP & BOTT.
3-#4 TOP & BOTT.
4-#4 TOP & BOTT.4-#4 TOP & BOTT.
3-#5 TOP & BOTT.3-#5 TOP & BOTT.
4-#5 TOP & BOTT.4-#5 TOP & BOTT.
4-#5 TOP & BOTT.4-#5 TOP & BOTT.
REINFORCING.
CUT ALT. WIRES
AT JOINT
VAPOR BARRIER
PER GEOTECHNICAL ENGINEER
(6 MIL. MIN.)
COMPACTED SUBGRADE AND
GRANULAR FILL
PER GEOTECHNICAL ENGINEER'S
RECOMMENDATIONS
SAND PER GEOTECHNICAL ENGINEER
PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO
BREAK UP SLAB INTO RECTANGULAR AREAS OF 400 SQUARE FEET OR
LESS. AREAS TO BE APPROX. SQUARE AND HAVE NO ACUTE ANGLES.
JOINT LOCATIONS TO BE APPROVED BY THE ARCHITECT.
SEE PLAN FOR
SLAB THICKNESS
AND REINFORCING
(TYP.)
1/8"X11/2" PREMOLDED CONTINUOUS
MASTIC JOINT STRIP OR PREMOLDED
CONSTRUCTION JOINT (MAY BE SAWCUT AT
OWNERS OPTIONS). SAWN JOINT SHALL BE
MADE AS SOON AS POSSIBLE WITHOUT
DAMAGE TO SURFACE.
VAPOR BARRIER
RE: GEOTECHNICAL ENGINEER
(6 MIL. MIN.)
COMPACTED SUBGRADE AND
GRANULAR FILL
RE: GEOTECHNICAL ENGINEER'S
RECOMMENDATIONS
SAND PER: GEOTECHNICAL ENGINEER
PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO
BREAK UP SLAB INTO RECTANGULAR AREAS OF 400 SQUARE FEET OR
LESS. AREAS TO BE APPROX. SQUARE AND HAVE NO ACUTE ANGLES.
JOINT LOCATIONS TO BE APPROVED BY THE ARCHITECT.
SEE PLAN FOR
SLAB THICKNESS
AND REINFORCING
(TYP.)
BURKE "KEYED KOLD" JOINT.
STOP REINFORCING CLEAR OF
JOINT EACH SIDE.
SECOND POUR FIRST POUR
INTERIOR NON-BEARING WALL
2X BOTTOM PL.
4" MIN. CONC. S.O.G.
4" MIN CLEAN WELL-GRADED GRAVEL
& SAND OVER COMPACTED SOIL PER
SOIL REPORT6-MIL
VAPOR RETARDER
SIMPS. PHNW 0.145" PIN @ 16" O/C
W/ 1 1/4" INTO S.O.G.
NOTE; SHEATHING NOT SHOWN
FOR CLARITY
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject AddressAs indicated
Project Number
Issue Date
Author
Checker
TYP.
FOUNDATION
DETAILSSINGH RESIDENCERAM S.SD01 34XX TALBOT RD RENTON WA1/2" = 1'-0"9
SLAB-ON-GRADE WITH MONOLITHIC
TURNED-DOWN FOOTING
1/2" = 1'-0"6
FOUNDATION_SLAB ON GRADE WITH
STEM WALL_GARAGE WALL
1/2" = 1'-0"8
FOUNDATION_SLAB ON GRADE_WITH
STEM WALL EXTERIOR WALL
3/4" = 1'-0"7
SINGLE LAYER HORIZONTAL WALL
REINFORCEMENT AT CORNER AND
INTERSECTION
1/2" = 1'-0"12
THICHENED SLAB-ON-GROUND
FOOTING
1/2" = 1'-0"11 WOOD COLUMN FOOTING
3/4" = 1'-0"3 RAISED CURB
3/4" = 1'-0"4 SILL PLATE AND BOLT DETAIL
1/2" = 1'-0"5 SILL PLATE SPLICE DETAILS
12" = 1'-0"1 TYP. SHRINKAGE CONTROL JOINT (S.J.)
12" = 1'-0"2 TYP. CONSTRUCTION JOINT (C.J.)
1/2" = 1'-0"10 NON-BEARING WALL FTG
04/27/2022
BBAA
FASTEN SHEATHING TO HEADER W/ 0.131" DIA
X 2.25" NAIL AT 3" O.C. GRID PATTERN AS
SHOWN AND AT 3" ON CENTER TO ALL
FRAMING
MAST27 W/ (30) 0.148" DIA. X3.25"
TOP PLATE TO HEADER
(2) 0.148" DIA. X3.25" @ 3" O.C.
TOP PLATE TO HEADER
(2) 0.148" DIA. X3.25" @ 3" O.C.
STHD 14 W/ (38)
0.148" DIA. X3.25"
5/8" DIA. ANCHOR BOLTS W/
7" MIN. EMEETMENT
MIN WIDTH=1'-4" FOR ONE STORY STRUCTURES
MIN WIDTH=2'-0" FOR TWO STORY STRUCTURES
(2) #4 AT T.O. WALL
(2) #4 VERT. MIN.
U.N.O. PER SCHEDULE
(2) #4 CONT. AT FOOTING
MIN. HEADER SIZE
3"X11.25" NET
7/16" MIN THICKNESS WOOD STRUCTURAL
PANEL SHEAHING
8"4"MIN. WIDTH 1'-4" MIN.4"8"MAX. HRIGHT 10'PLATE
6' MIN. TO 18' MAX.
EXTENT OF CONTINOUS HEADER
FRAMING PER PLAN1' - 4"1' - 4"
BB
SD01.1
AA
SD01.1
AA
SD01.1
BB
SD01.1
SHEATHING, NAILING
PER SHEARWALL SCHED.
PLATE NAILING
SHEATHING, NAILING
PER SHEARWALL SCHED.
FOUNDATION
DRAIN
BY OTHERS
#5 @ 12" AT TOE
#5 @ 12"
(2) #5 CONT.
SHEATHING, NAILING
PER SHEARWALL SCHED.
VERTICAL BARS
#4 @ 8" O.C.
LAP W/ DOWELS
HORIZ. BARS
#4 @ 10" O.C.
DOWEL BARS
#4 @ 8" O.C.
LAP=37"
#4 BAR: SPACING
TO MATCH DOWELS
FLOOR -9'-00"
#5 @ 12" AT TOE
FOUNDATION
DRAIN
BY OTHERS
#5 @ 12"
SEE 6/S6.0 FOR
INFO NOT SHOWN
BEGIN FRAMING LAYOUT
GARAGE S.O.G.
FLOOR 0'-0"
NOTE: SLAB ON GRADE MUST
BE IN PLACE PRIOR TO ANY
BACKFILLING GREATER THAN
6 FEET IN HEIGHT
8"TOE=2FT-6INHEEL=3FT-6IN 8" MIN.DEPTH=12IN3"HEIGHT="H"8" MIN.3"DEPTH=12INVERTICAL BARS
#4 @ 8" O.C.
LAP W/ DOWELS
HORIZ. BARS
#4 @ 10" O.C.
DOWEL BARS
#4 @ 8" O.C.
LAP=37"HEIGHT="H"JOIST BEARING CONDITION
2" CLR.
2" CLR.
BASE=6FT-0IN HEEL=3FT-6IN 8"TOE=2FT-6IN
BASE=6FT-0IN
FREE DRAINING
BACKFILL PER
GEOTECH. ENGR.
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject Address3/4" = 1'-0"
Project Number
Issue Date
Author
Checker
TYP.
FOUNDATION
DETAILSSINGH RESIDENCERAM S.SD01.1 34XX TALBOT RD RENTON WA3/4" = 1'-0"1
TYPICAL BRACED WALL PANEL
ADJACENT TO GARAGE DOOR-IBC
2308.9.3.2
3/4" = 1'-0"2
TYPICAL CANTILEVER RETAINING WALL
(SLAB ON GRADE BASEMENT)
04/27/2022
1/2" MAX.1/2" MAX.
WSP PER SCH.
1/2" MAX.
A.B. PER SCH.
7" MIN. EMBED IN
CONC.
EQ.EQ.
2x4 SHEAR WALL AND
ALL DOUBLE SIDED WSP
3"X3"X0.229" PL.B.N.B.N.
B.N.
2x6 SHEAR WALL AND
SINGLE SIDED WSP
FTG LEVEL FTG LEVEL
CORNER INTERSECTION
16d @ 12" O/C
EA. ROW
2X STUD
12" LONG BLOCK AT TOP
CENTER & BOTTOM
W/ 3-16d EA. BLOCK
12" LONG BLOCK AT TOP
CENTER & BOTTOM
W/ 3-16d EA. BLOCK
2X STUD
16d @ 12" O/C
EA. ROW
NOTE: SHEATHING NOT SHOWN FOR CLARITY.
NOTE;
1-SHEATHING NOT SHOWN FOR CLARITY.
2-SEE OTHER DETAILS FOR ADDITIONAL REQUIREMENTS.
3-SEE STRUCTURAL SPECIFICATIONS AND NOTES FOR
ADDITIONAL REQUIREMENTS.
THREADED ROD
HOLDDOWN PER PLAN
SEE HOLSDOWN SHC.
STUD/POST
PER HOLDDOWN SCH.2X OR 3X
PRESSURE TREATED PL.
CONCRETE FOUNDATION
PER PLAN
NOTE;
1-SHEATHING NOT SHOWN FOR CLARITY.
2-SEE OTHER DETAILS FOR MORE REQUIREMENTS.
3-SEE STRUCTURAL SPECIFICATIONS AND NOTES FOR
ADDITIONAL REQUIREMENTS.
THREADED ROD
2X STUD PER PLAN
NOTE;
1-SHEATHING NOT SHOWN FOR CLARITY.
2-SEE FOOTING DETAILS FOR ADDITIONAL
REQUIREMENTS.
3-SEE STRUCTURAL SPECIFICATIONS AND NOTES FOR
ADDITIONAL REQUIREMENTS.
2X OR 3X P.T. PL.
(3)-2X BLOCK`G
BLOCK`G NOT SHOWN
HOLDDOWN PER PLAN
SEE HOLD-DOWN SHC.
STEM WALL
OR BASEMENT WALL PER PLAN
CONT. RIM BOARD2-2X TOP PLA.
BEAM PER PLAN
(4) SIMPSON
LTP4 EA. SIDE OF THE BEAM
W/ (12) 0.131 x 11/2
NOTE;
1-SHEATHING NOT SHOWN FOR CLARITY.
2-SEE OTHER DETAILS FOR ADDITIONAL REQUIREMENTS.
3-SEE STRUCTURAL SPECIFICATIONS AND NOTES FOR
ADDITIONAL REQUIREMENTS.
STUD/POST
PER HOLDDOWN SCH.
(2)-2X BLOCK`G
2X STUD PER PLAN
FLOOR TO FLOOR STRAP TIEEND DISTANCE0' - 2 3/8"END DISTANCE0' - 2 3/8"STITCH NAILING
PER NAILING SCH.CLEAR SPANNOTE;
WHEN NAILING THE STRAP OVER THE
WOOD STRACTRAL PANEL (WSP), USE
2-1/2" LONG NAIL MIN.
NAILING NOR
REQUIRED
IN RIM AREA
CONT. RIM BOARD
2-2X TOP PL.
BEAM PER PLAN
MSTA37
CLIPS (LTP4 OR A35)
PER SHEAR WALL SCH.
W/ 12-0.131"X2-1/2" WHEN APPLIED
OVER SHEATHING OR;
12-0.131"X1-1/1" WHEN APPLIED
DIRECT TO FRAMING
DIAPHRAGM EDGE NAILING
BOTTOM PLA. CONNECTION PER SHEAR WALL
SCH.
PLYWOOD FLOOR SHEATHING
CONT. 2X RIM BOARD
STUDS
NOTE;
1-SHEATHING NOT SHOWN FOR CLARITY.
2-SEE OTHER DETAILS FOR MORE REQUIREMENTS.
3-SEE STRUCTURAL SPECIFICATIONS AND NOTES FOR
ADDITIONAL REQUIREMENTS.
INTERIOR SHEAR WALL
WSP PER PLAN
WSP PER PLAN
FLR SYSTEM
TRIPLE JOISTS,
AT SHEAR WALL ENDS
2X OR 3X PL.
HOLDDOWN PER PLAN
BLOCK`G NOT SHOWN
SHEAR WALL OFFSET
HOLDDOWN PER PLAN
A.B. PER HOLD-DOWN
SCHEDULE
5"X5"X3/8" A36 STEEL PL.
HOLD-DOWN &
A.B. PER PLAN
BEAM PER PLAN
2X OR 3X
PL. PER PLAN
POST PER HOLD DOWN SCH.
2X STUDS
SHEAR WALL OFFSET
NOTE:
1-HOLDOWN STUDS TO RECEIVE SHEARWALL PANEL EDGE NAILING.
2-FOUNDATION DETAILS NOT SHOWN FOR CLARIFY.
3-FOR ADDITIONAL REQUIREMENTS SEE SHEET S00.
NOTE: AT CORNER
CONDITIONS,
HOLDOWN STRAP MAY
BE LOCATED AT
EITHER FACE OF THE
STEM WALL.
8
SD028"CL HDU IN STUDHOLDOWN FASTENERS
AND WOOD STUDS PER
PLAN AND HOLDOWN
SCHEDULE
EMBEDMENT
PER SCHEDULE
#4 CONT.
HOLDOWN
PER PLAN
HOLDOWN
PER PLAN
EMBEDMENT
PER SCHEDULE
A: STRAP TYPE B: HOLDOWN
7
SD02
NOTE:
1-FOUNDATION DETAILS NOT SHOWN FOR CLARIFY.
2-FOR ADDITIONAL REQUIREMENTS SEE SHEET S00.
CL HOLDOWN IN STUD
EMBED. DEPTH PER SCHEDULEANCHOR ROD
DIAMETER PER
SCHEDULE
NUT/WASHER/NUT
NOTE:
1-FOUNDATION DETAILS NOT SHOWN FOR CLARIFY.
2-FOR ADDITIONAL REQUIREMENTS SEE SHEET S00.
4X PER PLAN
MSTC48B3
START NAILS 1 1/2" UP
FROM END OF STUD
NO NAILS REQ.
FACE NAILS
(12) 0.148" DIA. X3"
BEAM PER PLAN
(4) 0.148" DIA. X3"
2 7/8" PRE BENT(38) 0.148" DIA. X3"STUD/POST
PER HOLDDOWN SCH.
(3)-2X BLOCK`G
THREADED ROD
HOLDDOWN PER PLAN
SEE HOLSDOWN SHC.
2X STUD PER PLAN
HOLDDOWN PER PLAN
SEE SHC.
FLR. JST/RIM PER PLAN
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject Address3/4" = 1'-0"
Project Number
Issue Date
Author
Checker
STRUCTURAL
TYPICAL
DETAILSSINGH RESIDENCERAM S.SD02 34XX TALBOT RD RENTON WA3/4" = 1'-0"1 SW A.B. & PL. ARRANGEMENT
3/4" = 1'-0"2 CORNER AND INTERSECTIONS
3/4" = 1'-0"3 HOLDDOWN DETAILS_FOUNDATION
3/4" = 1'-0"4
HOLDDOWN
DETAILS_CRAWLSPACE/BASEMENT
3/4" = 1'-0"14 TOP PLATE SPLICE AT DROP BEAM
3/4" = 1'-0"5
HOLDDOWN DETAILS_FLOOR TO FLOOR
STRAP TIE
3/4" = 1'-0"15 TOP PLATE SPLICE AT DROP BEAM B
3/4" = 1'-0"16 TYPICAL CLIP (LTP5 OR A35)
3/4" = 1'-0"13 HOLDDOWN DETAILS_OFFSET
3/4" = 1'-0"7 HOLDOWN TO FOUNDATION
3/4" = 1'-0"8 HOLDOWN TO FOUNDATION-SECTION
3/4" = 1'-0"9 HOLDDOWN TO FOUNDATION SECTION
3/4" = 1'-0"10 HOLDOWN TO BEAM
3/4" = 1'-0"6 HOLDDOWN FLOOR TO FLOOR
04/27/2022
0' - 0 3/4"SPACING
PANEL EDGE
SHEATHING EDGE AT BOTTOM PL.
/SINGLE ROW OF FASTENERS 0' - 0 3/4"SPACING
PANEL EDGE
SHEATHING EDGE AT TOP PL.
/SINGLE ROW OF FASTENERS
SHEATHING EDGE AT BOTTOM PL.
/DOUBLE ROW OF FASTENERS
SPACING
PANEL EDGE
SHEATHING EDGE AT TOP PL.
/DOUBLE ROW OF FASTENERS0' - 0 1/2"0' - 0 1/2"SPACING
PANEL EDGE 0' - 0 1/2"SPACING
SPACING
PANEL ATTACHMENT 0' - 0 1/2"0' - 0 1/2"HORIZONTAL
PANEL EDGE
SPACING
SPACING
DOUBLE ROW FASTENERS 0' - 0 3/4"HORIZONTAL PANEL EDGE
SPACING
SINGLR ROW FASTENERS
0' - 0 1/2"PANEL SPLICE OVER HORIZONTAL FRAMING MEMBERS
PANEL SPLICE ACROSS STUDS
PANEL EDGE
0' - 0 3/4"SPACING BLOCK`G, SAME
SPECIES AS TOP PL.
(2XFLATWISE SHOWN)
INCREASE STUD
NAILING
INCREASE STUD
NAILING
INCREASE STUD
NAILING INCREASE STUD
NAILING
SHEAR WALL SCHEDULE
Label
ANSI/APA Rated
Sheating
[1][2][4][12][13]
Nail Size & Spacing @
Edges[4][5]
Stud &
Blocking
Size @
Adjoining
Edges
[3][6][14]
Rim Joist or
block
connection to
top plate
[7][8]
2X Bottom Plate Attachment Sill Plate Attachment
PLF Capacity
Nailing to Wood Below [9]
Anchor Bolt to
Concrete Below
[10][15]
Sill Plate Size
@ Foundation
[11]
W6 15/32" or 7/16" if [12]applied
one side 0.131x2-1/2 @ 6" O.C.2X6 Clip(A35 or LTP4)@ 24" O.C.0.148x3-1/4" @ 6" O.C.5/8" @ 48" O.C.2X6
W4 0.131x2-1/2 @ 4" O.C.2X6 Clip(A35 or LTP4)@ 16" O.C.0.148x3-1/4" @ 4" O.C.5/8" @ 32" O.C.2X6
W3 0.131x2-1/2 @ 3" O.C.2X6 Clip(A35 or LTP4)@ 12" O.C.
(2) ROWS 0.148x3-1/4" @
4-1/2" O.C.
5/8" @ 16" O.C.2X6
W2 0.131x2-1/2 @ 2" O.C.3X6 Clip(A35 or LTP4)@ 8" O.C.5/8" @ 12" O.C.2X6
2W3[2]0.131x2-1/2 @ 3" O.C. E.A. SIDE 3X6 Clip(A35 or LTP4)@ 12" O.C.
EACH SIDE 5/8" @ 16" O.C.3X6
2W2[2]0.131x2-1/2 @ 2" O.C. E.A. SIDE 3X6 Clip(A35 or LTP4)@ 8" O.C.
EACH SIDE 5/8" @ 12" O.C.3X6
0.148x3-1/4" @ 3" O.C.
(2) ROWS 0.148x3-1/4" @
3" O.C.
(2) ROWS 0.148x3-1/4" @
2" O.C.
Required Notes
[1] Install panels either horizontally or vertically.
[2] Where sheathing is applied on both sides of wall, panel edge joints on 2x framing shall be staggered so that joints on the opposite sides are not located on the same studs.
[3] Blockingis required at all panel edges.
[4] Provide shear wall sheathing and nailing for the entire length of the walls indicated on the plans. Ends of full height walls are designated by exterior of the building, corridors, windows, or doorways or as designated
on plans. See plans for hold-down requirements. (Alternate note: walls designated as perforated shear walls require sheathing above and below all openings).
[5] Sheathing edge nailing is required at all hold-down posts. Edge nailing may also be required to each stud used in built-up hold-down posts. Refer to the hold-down details for additional information.
[6] Intermediate framing to be with 2x minimum members. Field nailing 12" O.C.
[7] Based on 0.131x1-1/2" long nails used to attach framing clips directly to framing. Use 0.131x2-1/2" nails where installed oversheathing.
[8] Framing clips: A35 or LTP4 or approved equivalent.
[9] Where plate attachment specifies (2) rows of nails, provide double joist, rim or equal. Attach per details.
[10] (In Seismic Design Categories D, E & F) Anchor bolts shall be provided with steel plate washers 1/4"x3"x3". Embed anchorbolts 7" minimum into the concrete.
[11] Pressure treated material can cause excessive corrosion in the fasteners. Provide hot-dipped galvanized (electro-plating is not acceptable) nails and connector plates (framing angles, etc.) for all connectors in
contact
with pressure treated framing members.
Alternate Notes
[12] 7/16" APA rated sheathing (OSB) may be used in place of 15/32" sheathing provided that all studs are spaced at 16" O.C.
[13] Where wood sheathing (W) is applied over gypsum sheathing (G), contact the engineer of record for alternate nailing requirements.
[14] At adjoining panel edges, (2) 2x studs nailed together may be used in place of a single 3x stud. Double 2x studs may be connected together by nailing the studs together with 3" long nails of the same spacing and
diameter as the plate nailing.
[15] Contact the engineer of record for adhesive or expansion bolt alternatives to cast-in-place anchor bolts. (Special inspection may be required).
15/32" or 7/16" if [12]applied
one side
15/32" or 7/16" if [12]applied
one side
15/32" or 7/16" if [12]applied
one side
15/32" or 7/16" if [12]applied
two sides
15/32" or 7/16" if [12]applied
two sides
HOLD DOWN SCHEDULE
MODEL No.Ga.A.B. Dia.A.B. MODEL STEM WALL A.B. MIN. EMBED. (le)FASTENERS STUD THICKNESS
HDU14-SDS2.5 7
Required Notes
1. HOLD-DOWN MARKS ON PLAN APPLY THE BASE OF FRAMED WALLS ON THAT PLAN, OR TO TOP OF CONC. U.N.O.
2. PAELS FROM INTERSECTING SHEAR WALLS SHALL BE EDGE NAILED TO ALL HOLD DOWN MEMBERS TO SHARE CORNER HOLD-DOWNS. THE LARGER OF THE HOLD-DOWNS SPECIFIED SHALL BE
USED, U.N.O.
3. EDGE NAIL SHEATHING TO THE FOUNDATION MUD-SILL PLATE
5. HOLD-DOWN LOCATION AS SHOWN ON THE PLAN SUPERCEDES NOTE #4
6. PANEL EDGE NAILING SHALL BE EVENLY DISTRIBUTED AMONG MEMBERS IN HOLD-DOWN STUDS, W HICH SHALL BE LAMINATED TOGETHER WITH 12d @ 6" O.C. U.N.O.
7. GRADE A36 THD'D ROD OF SAME ⌀MAY BE USED IN LIEU OF 'PAB'. A x 2 1/2 x 2 1/2" PL WASHER SHALL BE INSTALLED AT THE BASE, NUTTED BOTH SIDES W/ A HEAVY HEX NUT AT THE BOTTOM
SIDE
NOTE
1"PAB8 11"(36) 1/4" x 2 1/2" SDS 5 1/2"x5 1/2"USE; HEAVY HEX ANCHOR NUT
HDU11-SDS2.5 10 1"PAB8 11"(30) 1/4" x 2 1/2" SDS 3 1/2"x7 1/4"SEE SIMPSON C-C-2019/TABLE 1
HDU8-SDS2.5 10 7/8"PAB7 10"(20) 1/4" x 2 1/2" SDS 3 1/2"x4 1/2"SEE SIMPSON C-C-2019/TABLE 1
HDU5-SDS2.5 14 5/8"SB5/8X24 18"(14) 1/4" x 2 1/2" SDS 3x3 1/2"SEE SIMPSON C-C-2019/TABLE 1
HDU2-SDS2.5 14 20 5/8"(6) 1/4" x 2 1/2" SDS 3x3 1/2"SEE SIMPSON C-C-2019/TABLE 1
DTT2Z 14 12 5/8"(8) 1/4" x 2 1/2" SDS 3x3 1/2"SEE SIMPSON C-C-2019/TABLE 1
MSTC52 16 36-16d SINKER STRAP TIE; 24" CLEAR SPAN
MSTC40 16 STRAP TIE; 24" CLEAR SPAN
LTT19 16 SEE SIMPSON C-C-2019/TABLE 1
LTT20B 12 SEE SIMPSON C-C-2019/TABLE 1
LTT131 18 SEE SIMPSON C-C-2019/TABLE 1
HTT4 11 SEE SIMPSON C-C-2019/TABLE 1
HTT5 11 SEE SIMPSON C-C-2019/TABLE 1
HD3B 12 BODY GA.3 1/2"x3 1/2"SEE SIMPSON C-C-2019/TABLE 1
HD5B 10 BODY GA.3 1/2"x3 1/2"SEE SIMPSON C-C-2019/TABLE 1
HD7B 10 BODY GA.3 1/2"x3 1/2"SEE SIMPSON C-C-2019/TABLE 1
HD9B 7 BODY GA.3 1/2"x4 1/2"SEE SIMPSON C-C-2019/TABLE 1
HD12 3 BODY GA.3 1/2"x4 1/2"SEE SIMPSON C-C-2019/TABLE 1
HDU4-SDS2.5 14 18"(10) 1/4" x 2 1/2" SDS 3x3 1/2"SEE SIMPSON C-C-2019/TABLE 15/8"
5/8"
1/2"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
5/8"
7/8"
7/8"
1 1/8"
SB5/8X24
SSTB24
SSTB16
SSTB16
SSTB16
SSTB16
SSTB24
PAB7
PAB7
PAB8
SB5/8X24
SB5/8X24
SB5/8X24
12 5/8"
12 5/8"
12 5/8"
18"
18"
20 5/8"
20 5/8"
10"
10"
11"
20-16d SINKER
(8) 0.148 x 3
(10) 0.148 x 3
(18) 0.148 x 1 1/2"
(18) SD#10 x 1 1/2"
(26) 0.162 x 2 1/2"
(2) x5/8" STUD BOLTS
(2) x3/4" STUD BOLTS
(3) x3/4" STUD BOLTS
(3) x7/8" STUD BOLTS
(4) x1" STUD BOLTS
3x3 1/2"
3x3 1/2"
3x3 1/2"
3x3 1/2"
3x3 1/2"
4. HOLD-DOWNS OCCUR AT EACH END OF EACH SHEARWALL SEGMENT
SEE SIMPSON C-C-2019/TABLE 1STHD141214"(24) 0.148 x 3-1/4"
E.N.E.N.
E.N.
E.N.
4-8d COMMON TOE NAILS
3-16d COMMON END NAILS
2-16d COMMON END NAILS
2-16d COMMON END NAILS
EXTERIOR SHEAR WALL
EXTERIOR SHEAR WALL
FLR SYSTEM PER PLAN
2X OR I-JST PER PLAN
NOTE;
SEE NAILING SCH. & SHEAR
WALL SHC. FOR MORE INFO.
E.N.
E.N.
E.N.
3-16d COMMON END NAILS
2-16d COMMON END NAILS
EXTERIOR SHEAR WALL
FLR SYSTEM PER PLAN
2X OR I-JST PER PLAN
5/8" X10" A.B. W/ 3"X3"X0.229" PL.
MIN. 7" EMBED IN CONC.
@48" O/C MAX. SEE SHEAR WALL SCH.
W/12" FROM EACH CORNER
CONC. STEM WALL PER PLAN
E.N.
E.N.
E.N.
E.N.
3-16d COMMON END NAILS
2-16d COMMON END NAILS
2-16d COMMON END NAILS
EXTERIOR SHEAR WALL
EXTERIOR SHEAR WALL
FLR SYSTEM PER PLAN
2X OR 3X BOTTOM PL.
2X OR 3X BOTTOM PL.
2X OR 3X BOTTOM PL.
2X FULL HT. BLOCKING
1ST & 2ND BAYS @ 48" O/C
3-16d COMMON FACE NAILS
EXTERIOR SHEAR WALL_FLOOR DIAPHRAGM
WITH FLOOR JOISTS PARALLEL TO WALL
EXTERIOR SHEAR WALL_FLOOR DIAPHRAGM
WITH FLOOR JOISTS PERPENDICULAR TO WALL
EXTERIOR SHEAR WALL_FLR DIAPHRAGM
WITH FLR JOISTS PERPENDICULAR TO WALL
2X CONT. RIM BOARD IN W6
2-2X IN W3 & W4
4X IN W2, 2W3 & 2W2
SHEAR PANEL,
PER PLAN & SHC.SHEAR PANEL,
PER PLAN & SHC.
SHEAR PANEL,
PER PLAN & SHC.
2X BLOCKING
W/ 16d @ 8" O/C
2-16d PER FOOT
2-8d PER FOOT
2-16d PER FOOT
2x6 PT SILL .
2-2x TOP PL.
2-2x TOP PL.
1-1/4"X20 GAGE ASTM 36
G. 33 STEEL STARAP @ 48 "O/C
LAPPED UNDER SILL PL.
1-1/4"X20 GAGE ASTM 36
G. 33 STEEL STARAP @ 48 "O/C
1-1/4"X20 GAGE ASTM 36
G. 33 STEEL STARAP @ 48 "O/C
2X CONT. RIM BOARD IN W6
2-2X IN W3 & W4
4X IN W2, 2W3 & 2W2
2X CONT. RIM BOARD IN W6
2-2X IN W3 & W4
4X IN W2, 2W3 & 2W2
Clip(A35 or LTP4) PER SHEAR WALL
SCH. W/(12)0.131X2-1/2"
Clip(A35 or LTP4) PER SHEAR WALL
SCH. W/(12)0.131X2-1/2"
Clip(A35 or LTP4) PER SHEAR WALL
SCH. W/(12)0.131X2-1/2"
SHEAR PANEL,
PER PLAN & SHC.
SHEAR PANEL,
PER PLAN & SHC.
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject Address3/4" = 1'-0"
Project Number
Issue Date
Author
Checker
STRUCTURAL
TYPICAL
DETAILSSINGH RESIDENCERAM S.SD2.1 34XX TALBOT RD RENTON WA3/4" = 1'-0"2
WOOD STRUCTURAL PANEL (WSP)
ATTACHMENTS
3/4" = 1'-0"1
SHEAR TRANSFER AND FRAMING
DETAILS
04/27/2022
POST PER PLAN
WOOD BEAM OR
GLULAM BEAM
SIMPS. POST CAP
PER PLAN
DBL. TOP PL.SHEET METAL STAP
2X OR TJI JST
PER PLAN
2X OR TJI JST
PER PLAN
GLULAM OR SOLID SAWN
BEAM PER PLAN
WOOD STRUCTURAL
PANEL(WSP) SHEATHING
SIMPS. METAL HANGER PER PLAN
SIMPS. TIE STRAP
LSTA 24 @ 48" O/C
WEB STIFFENERS EA. SIDE
PER MANUFACTURER
WEB STIFFENERS EA. SIDE
PER MANUFACTURER
SIMPS. TIE STRAP
LSTA 24
SIMPS. METAL HANGER
PER PLAN
GLULAM OR
SOLID BEAM
BEAM PER PLAN
STUD
BOTTOM PL.
DBL. JOIST PER PLAN JST PER PLAN
2X4 @ 32" O/C
FLR SYSTEM FLR SYSTEM
2-8d EA. SIDE
MIN.
0' - 2"
SPLICE
0' - 10"
20d @ 32" O/C STAGGER
IN 2 ROW
3/4" MIN.2-20d FACE NAILS
@ ENDS & SPLICE
20d=4"x0.192"
0' - 2"
0' - 2"
2" LUMBER LAYERS
BEAM SIZE PER PLAN
BEAM PER PLAN
SIMPS. ECC66
W/ 2-5/8" BOLTS TO BEAM &
2-5/8" BOLTS TO POST
6X6 POST
0.5" CLEARANCE
POST 6X6SIMPS. CC66
W/ 2-5/8" BOLTS TO POST &
4-5/8" BOLTS TO BEAM
LSTA24 STRAP EA. SIDE
W/(18)-10d
POST CL
BEAM PER PLAN
(2)-SIMPS. ST6215 STRAP TIE
EA.SIDE OF BEAM
CONNECTED AS SHOWN
W/ (20)0.162X2-1/2"
6X6 POSTPOST CL
WOOD BEAM
PER PLAN
(2) 16d COMM. TE NAILS
EA. SIDE
EXTERIOR WALL
PER PLAN
WOOD BEAM
PER PLAN
(2) 16d COMM. TE NAILS
EA. SIDE
INTERIOR WALL
PER PLAN
(3) 2X STUDS U.N.O.
16d EA. FLANGE
CONT. RIM BOARD
(2)-8d EA. SIDE
(4) 8d CLENCHED
NOTE: WEB
STIFFENER AS REQ'D
PER JOIST SUPPLIER
2X4 SQUASH BLOCK
QTY. TO MATCH
STUDS/POST ABOVE
WEB STIFFENER EA.
PER SUPPLIER
NOTE: SQUASH
BLOCK REQ'D WHEN
POST ABOVE
JOIST TO BRG. PL.WEB STIFFENER SQUASH BLOCK1/8" GAP1/16" GAPSIMPS. TIE STRAP
LSTA 24 @ 48" O/C
SIMPS. METAL HANGER
2x JOIST PER PLAN
BEAM PER PLAN
BEARING AND/OR
SHEARWALL PER PLAN
PLATE NAILING PER
SHEARWALL SCHEDULE
0.148"X3.25" @ 6" O.C. MIN.
EDGE NAILING PER SCHED.
RIM/BLOCKING TO TOP
PLATE PER SHEARWALL
SCHEDULE-PROVIDE
0.148"X3.25" @ 6" O.C. MIN.
EDGE NAILING PER SCHED.
BEARING AND/OR
SHEARWALL PER PLAN
FLOOR SHEATHING AND NAILING
PER STRUCTURAL NOTES S00
BLOCKING AT 48" O.C.
ADD RIM JOIST/BLKG.
AS REQUIRED BY
SHEARWALL SCHEDULE
FRAMING PER PLAN
(3) 0.148"X3"
NOTES:
1. SECURE JOIST TO WALL WITH
0.131"X2.5" EA. SIDE, 1 1/2" MIN.
FROM END.
2. SECURE RIM JOIST TO BLKG. WITH
0.131"X2.5" NAIL TOP AND BOTTOM.
JOISTS PARALLEL
3-16d COMM END NAILS
BEARING AND/OR
SHEARWALL PER PLAN
PLATE NAILING PER
SHEARWALL SCHEDULE
0.148"X3.25" @ 6" O.C. MIN.
E.N. PER SCHED.
RIM/BLOCKING TO TOP
PLATE PER SHEARWALL
SCHEDULE-PROVIDE
0.148"X3.25" @ 6" O.C. MIN.
E.N. PER SCHED.
BEARING AND/OR
SHEARWALL PER PLAN
FLOOR WSP
NAILING PER NOTES IN S00
FLOOR JST. PER PLAN
DOUBLE JOIST
JOISTS PARALLEL
BEARING AND/OR
SHEARWALL PER PLAN
PLATE NAILING PER
SHEARWALL SCHEDULE
0.148"X3.25" @ 6" O.C. MIN.
EDGE NAILING PER SCHED.
RIM/BLOCKING TO TOP
PLATE PER SHEARWALL
SCHEDULE-PROVIDE
0.148"X3.25" @ 6" O.C. MIN.
E.N. PER SCHED.
BEARING AND/OR
SHEARWALL PER PLAN
CANTILEVER AT SIM.
FLOOR WSP
PER STRUCTURAL NOTES S00
ADD RIM JOIST/BLKG.
AS REQUIRED BY
SHEARWALL SCHEDULE
FRAMING PER PLAN
NOTES:
1. SECURE JOIST TO WALL WITH
0.131"X2.5" EA. SIDE, 1 1/2" MIN.
FROM END.
2. SECURE RIM JOIST TO BLKG. WITH
0.131"X2.5" NAIL TOP AND BOTTOM.
JOISTS PERPENDICULAR
BEARING AND/OR
SHEARWALL PER PLAN
PLATE NAILING PER
SHEARWALL SCHEDULE
0.148"X3.25" @ 6" O.C. MIN.
EDGE NAILING PER SCHED.
RIM/BLOCKING TO TOP
PLATE PER SHEARWALL
SCHEDULE-PROVIDE
0.148"X3.25" @ 6" O.C. MIN.
E.N. PER SCHED.
BEARING AND/OR
SHEARWALL PER PLAN
FLOOR SHEATHING AND NAILING
PER STRUCTURAL NOTES S00
ADD RIM JOIST/BLKG.
AS REQUIRED BY
SHEARWALL SCHEDULE
JOIST PER PLAN
NOTES:
1. SECURE JOIST TO WALL WITH
0.131"X2.5" EA. SIDE, 1 1/2" MIN.
FROM END.
JOISTS PERPENDICULAR
NOTE: PROVIDE WEB STIFFENERS
IF REQUIRED BY JOIST MFR.
"I" JOIST DIMENSIONAL LUMBER
BUNDLED JOISTS PER PLAN
(2) 0.162X3.5" NAILS AT
12" O.C. EA. SIDE STAGGERED
JOISTS PER PLAN
JOIST HANGER TO MATCH
JOISTS-SEE STRUCTURAL
NOTES S00
WEB FILLER BLOCKS
REQ. AT BUILT UP "I"
JOISTS
JOIST PER
PLAN
JOIST HANGER
FLOOR WSP
FLOOR WSP
JOIST & HANGER
PER PLAN
FLUSH BEAM PER PLAN
FLUSH BEAM
FLOOR WSP
JOIST
PER PLAN
DROPPED BEAM PER PLAN
DROPPED BEAM
2X-FULL HEIGHT BLOCKS
W/ 8d COMM. @ 6" O/C
TOENAILS
METAL PIECES
NOT TO TOUCH.
NOTES:
1. PROVIDE BRIDGING @ INTERVALS NOT EXCEEDING 6'-0" O.C.
2. PROVIDE ONE LINE OF BRIDGING NOT FARTHER THAN 4"
FROM EACH END OF EACH JOIST.
20 GA. NAILABLE
METAL CROSS
BRIDGING, TYP.
2-10d NAILS
EA. END, TYP.
I-JOIST TYP.
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject Address3/4" = 1'-0"
Project Number
Issue Date
Author
Checker
STRUCTURAL
TYPICAL
DETAILSSINGH RESIDENCERAM S.SD03 34XX TALBOT RD RENTON WA3/4" = 1'-0"6 WOOD END COLUMN WITH STRAP
3/4" = 1'-0"5 BEAM JOIST CONNECTION
3/4" = 1'-0"9 BEAM TO BEAM CONNECTION
3/4" = 1'-0"10
NON-LOAD BEARING WALL TO FLOOR
CONNECTION
3/4" = 1'-0"11 BUILT-UP BEAM OR GIRDER
3/4" = 1'-0"2
WOOD BEAM TO END COLUMN
CONNECTION
3/4" = 1'-0"1 WOOD BEAM TO COLUMN CONNECTION
3/4" = 1'-0"3
WOOD BEAM TO END COLUMN WITH
STRAP TIE
3/4" = 1'-0"4
WOOD BEAM COLUMN TOENAIL
CONNECTION
3/4" = 1'-0"7 I-JOIST NAILING REQS. AT BEARING
3/4" = 1'-0"8 BEAM TO JOIST
3/4" = 1'-0"15 TYPICAL EXTERIOR WALL TO FRAME
3/4" = 1'-0"16 TYPICAL EXTERIOR WALL TO FRAME
3/4" = 1'-0"18 TYPICAL EXTERIOR WALL TO FRAME
3/4" = 1'-0"17 TYPICAL INTERIOR WALL TO FRAME
3/4" = 1'-0"12 TYPICAL BUILT-UP BEAM
3/4" = 1'-0"13 TYP. FRAMING TO BEAM
3/4" = 1'-0"14 I-JOIST BRIDGING DETAIL
04/27/2022
TREADS; 2X OR 5/4 BOARDS
2X12 STRINGER@ 18" O/C MAX.
SEE ARCH. DRAW`G MAX.0' - 7 3/4"1" NOSE
SIMPSON SLOPED JST HANGER
MIN. CAPACITY=1575lb
3-2X12 JST
FLR SYSTEM
TREADS; 2X OR 5/4 BOARDS
2X12 STRINGER@ 18" O/C MAX.
SEE ARCH. DRAW`G MAX.0' - 7 3/4"1" NOSEMIN.0' - 5"4" SOG
0' - 6"0' - 4"0' - 4"
2-#41' - 6"3"X"3X1/4"X0'-3" ANGLE
W/ 1/2" BOLT @ EA. LEG &
@ EA. STRINGER
TREADS; 2X OR 5/4 BOARDS
2X12 STRINGER@ 18" O/C MAX.
SEE ARCH. DRAW`G MAX.0' - 7 3/4"1" NOSEMIN.0' - 5"FLR SYSTEM
3-2X12 JST
2X8 BLOCK`G
W/ 2-16d NAILS @ 6" O/C
MIN.
0' - 10"
MIN.
0' - 10"
MIN.
0' - 10"0' - 5"(2) 1/2" DIAMETER THROUGH-BOLTS WITH
WASHERS REQUIRED ONLY IF GUARD IS
REQUIRED; OTHERWISE USE (2) #8 WOOD
SCREWS ≥3-1/2" LONG OR (2) 16d
THREADED NAILS
4x4 POST
18" MIN.
6" MIN.
FROST DEPTH
10"x10" SQUARE OR
12" DIA. FOOTING
CUT POST AT BOTTOM TREAD ELEVATION WHEN
NO STAIR GUARD IS REQUIRED
STAIR
STRINGER
ATTACH 2x4 BEARING BLOCK USING (8) #8
WOOD SCREWS ≥3-1/2" LONG OR (8) 16d
THREADED NAILS
SECTION
FLR LEVEL
HEADER
SEE SHC.
SEE ARCH. DRAW`G
ROUGH OPENING
CONT. PL. TO MATCH STUD
SIZE WHEN USE DBL JST
HEADER
2X STUD @
16" O/C
2-2X TOP PL.
W/ 16-d @ 18" O/C
MIN. 2 JACK STUDS
MIN. 2 FULL HEIGHT
STUDS
2X SILL PL.
FRAMING ANGLES
EA. SIDE TOP & BOTTOM OF
FULL HEIGHT STUD
2X CRIPPLES
@ 16" O/C
(SPLICE OVER BEAR`G)
4'-0" MIN. BTWN. SPLICESNO SPLICE ALLOWED OVER HEADERS
14-16d EA. SIDE OF SPLICE OR;
20-16d EA. SIDE OF SPLICES
@ SHEAR WALLS
NO SPLICE ALLOWED AT
HEADER LOCATION
3-16d FACE NAIL3-16d FACE NAIL
16d-COMMON
@ 12" O/C
2X STUDS @ 16" O/C
16d-FACE NAIL @ 12" O/C
FRAMING ANGLE
EA. OF HEDER
BLOCKING AS REQUIRED
2X OR 3X
TREATED PL.
NOTE:
USE HANGERS WITH CONCEALED FLANGES FOR HEADER AND MIN
6x6 POSTS AT SPANS GREATER THAN 10'-0" OR AT GLULAM BEAMS
UP TO 4'-0"
MAX. ROUGH
OPENING
4'-1" TO 6'-0"
6'-1" TO 8'-0"
8'-1" TO 10'-0"
HEADER, U.N.O.
3 1/8"x15"GLB OR 5 1/8"x10 1/2"GLB
3 1/8"x12"GLB OR 6x12
6x10 OR 4x14
6x6 OR 4x10
8'-1" TO 10'-0"
6'-1" TO 8'-0"
4'-1" TO 6'-0"
MAX. ROUGH
OPENING
UP TO 4'-0"
HEADER, U.N.O.
6x6 OR 4x8
6x8 OR 4x10
6x10 OR 4x12
6x12 OR 4x14
OVER 10'-0"SEE PLANS
OVER 10'-0"SEE PLANS
STUD WALL HEADER AT FLOOR OPENING
STUD WALL HEADER AT ROOF OPENING
FROM END
0' - 6"7 IN MIN.FLOOR
OR FOUNDATION LEVEL
D/3 MAX
D/4 MAXD/6 MAXDMIN2"MAXD/3 MAXD/6OUTER 1/3 OF SPAN
NOTCHING NOT PERMITTED
MIDDLE 1/3 OF SPAN OUTER 1/3 OF SPAN
BEAMS & PURLINS
WWPA AND NDS PRESCRIPTIVE
RECOMMENDATIONS
MAX
D/4
MAX
D/2.5
D D
EXTERIOR
AND BEARING
WALLS
NON- BEARING
WALLS
5/8" MIN
40%
5/8" MIN
5/8" MIN 60%5/8" MIN
ANY WALL
NON- BEARING WALLS
OR NOT MORE THAN 2
SUCCESSIVE STUDS
BORED AND DOUBLED
ELECTRICAL OR PLUMBING PROTECTION
USE APPROVED STUD SHOE
FOR LARGER OPENINGS.
INSTALL PER MANUFACTURER
INSTRUCTIONS
DRILL D/6⌀HOLE
BEFORE CUTTING
NOTCH IN WOOD
APPROVED NAIL
STOPPER PLATE
WOOD STUD(S)
AS REQUIRED
NOTE:
THIS DETAIL SHALL APPLY
FOR ELECTRICAL CONDUITS,
PLUMBING AND FOR ANY
OTHER USES WHICH
REQUIRED NOTCHING.
D/6 MAX
3/4" CLR._STC_VERTICALLY SLOTTED
CLIP @ EACH BLOCK
2x TOP PLATE
2x STUDS PER PLAN
2x BLOCKING @ _48_" O.C.
w/ (3) 16d EACH END
JOISTS PER PLAN
3/4" CLR._STC_VERTICALLY SLOTTED
CLIP @ _48_" O.C. TO JOIST
2x TOP PLATE
2x STUDS PER PLAN
JOISTS PER PLAN
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject AddressAs indicated
Project Number
Issue Date
Author
Checker
STRUCTURAL
TYPICAL
DETAILSSINGH RESIDENCERAM S.SD3.1 34XX TALBOT RD RENTON WA3/4" = 1'-0"3 WOOD STAIR DETAILS
3/4" = 1'-0"1 TYP. STUD WALL CONSTRUCTION
1" = 1'-0"2
NOTCHES AND PENETRATIONS IN
SOLID SAWN JOISTS AND STUDS
NTS4NON-BEARING PARTITION WALL - TOP
04/27/2022
DEPTH, DJST DDEPTHD/4 MAX.TRUSS TOP
CHORD OR
RAFTER PER
PLAN
ROOF WSP
PER SPEC.
2X4 BLOCK`G
W/ 2-10d EACH SIDE
SIMPS. LSTA21 RIDGE STRAP
W/ (16)-16d EVERY RAFTER OR TOP CHORD
NOTE;
1. SEE ROOF NOTE & NAILING SCH.
FOR ADDITIONAL REQUIRMENTS.
EXTERIOR
END WALL PER PLAN
2-2X TOP PL.
E.N.
2X4 HORIZONRAL BRACE
W/ (4)-10d TO TRUSS
VERTICALS
2X6 HORIZONRAL BRACE
W/ (2)-10d TO TRUSS
VERTICALS
END GABLE TRUSS
VERTICALS
WOOD STRUCTURAL
PANEL SHEAR WALL
PER PLAN
MAX.
1' - 0"
2-10d FACE NAILS
EA. END
B.N.
8d @ 6" O/C
4-10d PER
BLOCK`G
4-10d PER
BLOCK`G
2X4 BLOCK`G @ 24" O/C
ROOF TRUSS
PER PLAN
2-10d FACE NAIL
EA. END
2X4 BLOCK`G @ 24" O/C
2-10d FACE NAIL
EA. END
A34 FRAMING ANGLE
@ 24" O/C
2X6 DIAGONAL BRACING @48" O/C
W/ (4)-16d COMMON WIRE NAILS TO TRUSS VERTICALS &
W/(5)-10d COMMON WIRE NAILS TO BLOCKING
DIAGONAL BRACE @ 1/3
POINTS IF NEEDED
10d @ 4" o/c
PANEL NAILING SEE NOTES
PANEL NAILING
SEE NOTES
2x STUD
PER PLAN
TOP PLATE
(2)-SIMPS. RPS18
STRAP TIE W/
12-16d
PIPE
NOTCH GREATER
THAN 50 PERCENT OF
THE PLATE WIDTH
CHORD OR RAFTER
ROOF WSP
SLOPE
PER PLAN
OVER FRAMING
TRUSS PER PLAN
2X6 CONT. PL.
W/ 3-10d
8d @ 8" O/C
3-16d TOE NAILS
@ EA TRUSS BOTTOM CHORD
TO RAFTER OR CHORD TYP.
8d @ 4" O.C.
SIMPS. H2A @ 24" O.C.
2X4 MIN. OUTLOOKER
W/ (2) 12d EA. SIDE
GABLE ENDWALL
2X BLOCKS
W/ 8d @ 6" O.C.
L
L/2 OR 2'
LESSER OF
8d @ 4" O.C.
TRUSS PER PLAN
ROOF WSP
8d @ 4" O.C.
2X LOOKOUT BLOCK
W/ (2) 12 d EA. SIDE
GABLE END TRUSS OR ENDWALL
≤1'
TRUSS PER PLAN
8d @ 4" O.C.ROOF WSP
ROOF SHEATHING PER STRUCTURAL
NOTES, SHEET S00
SIMPS. H2.5A @ 24" O.C.
W/ (5) 8d (.131X1 1/2") TRUSS
W/ (5) 8d (.131X1 1/2") TOP PLATE
BEAM/HDR @ SIM.
SECTION
ARCHITECTURAL
BLOCK AS REQ'D
BY SIDING/TRIMS
P.E.N. PER PLAN
SEE SHEAR WALL
SCHEDULE S00.1
2X VENTED BLKG.
TOE NAIL TO TRUSS
W/ (2) 12D EACH SIDE
(.148" DIA. X3 1/4")
8D @ 6" O.C.
A35 @ 48" O.C.
(6) 10D X1 1/2"
(.148" DIA. X1 1/2")
ROOF FRAMING
PER PLAN
SIMPS. H2.5A @ 48" O.C. TOP PL.
TO STUD
W/ (5) 8d (.131X1 1/2") TRUSS
W/ (5) 8d (.131X1 1/2") TOP PLATE
GIRDER TRUSS
G.T. PER PLAN
LGT CONNECTOR SEE PLANS
2-2X PLATE
STUDS
MODEL QTY.NO. OF
PLIES
LGT2
LGT3-SDS2.5
LGT4-SDS3
1
1
1
2
3
4
FASTENERS TO GIRDER
(16) 0.148X3 1/4"
(12) 1/4"X2 1/2" SDS
(16) 1/4"X3" SDS MAX. GAP0' - 0 1/4"MAX. GAP0' - 0 1/4"WALL PARALLELWALL PERPENDICULAR
NON BEARING WALL NON BEARING WALL
STC ROOF TRUSS CLIPS
@ 48" O.C.
2X4 @ 48" O.C.(2) 12d EA. END
DS DRYWALL STOP @ 16" O.C.
1' - 4"
1/2" DRYWALL (MIN.12")
5/8" DRYWALL (MIN.16")
BOTTOM CHORD
OR CEILLING JOIST
EX. CHORD OR RAFTER
EX. ROOF WSP
12
SLOPE
PER PLAN
WSP PER PLAN
2X OVER FRAMING
RAFTER PER PLAN
2-10d COMMON
TOE NAILS @ 8" O/C
NOTES:
1-THESE DRAWINGS ARE THE PROPRIETARY WORK
PRODUCT AND PROPERTY OF(WILSON & HAJ CONSULTANT
ENGINEERS, LLC), DEVELOPED FOR THE EXCLUSIVE USE OF
(WILSON & HAJ CONSULTANT ENGINEERS, LLC). USE OF
THESE DRAWINGS AND CONCEPTS CONTAINED THEREIN
WITHOUT THE WRITTEN PERMISSION OF (WILSON & HAJ
CONSULTANT ENGINEERS, LLC) IS PROHIBITED.
2-TO THE BEST OF MY KNOWLEDGE THESE PLANS ARE
DRAWN TO COMPLY WITH OWNER'S AND/ OR BUILDER'S
SPECIFICATIONS AND ANY CHANGES MADE ON THEM AFTER
PRINTS ARE MADE WILL BE DONE AT THE OWNER'S AND /
OR BUILDER'S EXPENSE AND RESPONSIBILITY. THE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
ENCLOSED DRAWING. WILSON & HAJ CONSULTANT
ENGINEERS,LLC IS NOT LIABLE FOR ERRORS ONCE
CONSTRUCTION HAS BEGUN. WHILE EVERY EFFORT HAS
BEEN MADE IN THE PREPARATION OF THIS PLAN TO AVOID
MISTAKES, THE MAKER CAN NOT GUARANTEE AGAINST
HUMAN ERROR. THE CONTRACTOR OF THE JOB MUST
CHECK ALL DIMENSIONS AND OTHER DETAILS PRIOR TO
CONSTRUCTION AND BE SOLELY RESPONSIBLE
THEREAFTER.
3-CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE AND NOTIFY THE DESIGNER
OF ANY DIMENSIONAL ERRORS, OMISSIONS OR
DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY
WORK.
Scale
Checked By
Drawn By
Date
Project number
Rev#Description Date
Revisions Client NameProject AddressAs indicated
Project Number
Issue Date
Author
Checker
STRUCTURAL
TYPICAL
DETAILSSINGH RESIDENCERAM S.SD04 34XX TALBOT RD RENTON WA3/4" = 1'-0"3 CEILING JOIST TAPER CUT
3/4" = 1'-0"2 RIDGE STRAP & RAFTER CONNECTION
3/8" = 1'-0"4 SAMPLE ENDGABLE TRUSS
3/4" = 1'-0"5
TOP PLATE FRAMING TO
ACCOMMODATE PIPING
3/4" = 1'-0"12 OVER FRAMING CONNECTION
3/4" = 1'-0"7 RAKE OVERHANG _OUTLOOKER
3/4" = 1'-0"8 RAKE OVERHANG_LOOKOUT BLOCKS
3/4" = 1'-0"1 EXTERIOR WALL AT ROOF
3/4" = 1'-0"6 GIRDER TRUSS TO PLATE CONNECTION
3/4" = 1'-0"9 NON BEARING WALL CONNECTION
3/4" = 1'-0"18 RAFTER OVER FRAMING CONNECTION
04/27/2022