Loading...
HomeMy WebLinkAboutP_Preliminary_Architectural_Design_Plan_Set_230222_v14 A-2013 A-2012 A-2011 A-201A-5151Generator EnclosureDumpster EnclosureReceiving EntranceEdge of canopy overheadEdge of canopy overheadProperty Line15' Building SetbackAmbulance Drop-OffEmergency Drop-Off118 SFSoiled WorkRoom170 SFGeneralStorage163 SFObservation136 SFObservation138 SFObservation166 SFObservation166 SFExam166 SFExam176 SFExam277 SFMajor Exam/Treatment/Trauma165 SFExam50 SFPatientToilet37 SFHSKP163 SFExam158 SFExam163 SFExam175 SFExam64 SFPatientToilet/Shower49 SFPatientToilet165 SFIsolation118 SFClean Supply123 SFMedication64 SFPatientToilet/Shower176 SFLab119 SFMDF97 SFMed Gas72 SFStaffToilet/Shower248 SFMechanical306 SFCorridor122 SFEquipmentStorage375 SFX-Ray54 SFTriage54 SFPublicToilet66 SFOffice/Dictation65 SFOffice55 SFOffice48 SFStaffToilet302 SFStaffLounge172 SFElectrical46 SFEngineeringOffice232 SFControl Booth378 SFCT Scan100 SFRecords/Support188 SFRegistration332 SFCorridor305 SFNurse Station44 SFNourishment326 SFCorridor184 SFVestibule752 SFWaiting742 SFCorridor269 SFCorridorEdge of canopy overheadEdge of canopy overheadDepartment LegendAdministrationCirculationEmergency DepartmentFacilities DepartmentImaging DepartmentObservationLaboratoryPublicStaff SupportSupport AreasRTU aboveRTU above11275 S. Sam Houston Parkway W.Suite 200 | Houston, Texas 77031832.554.1130 | philowilke.comConsultantsPreliminary Review OnlyNot for Permit or ConstructionBy:Date:P&W Commission NumberSheet NumberCopyright (C) 2023 by PhiloWilke Partnership. All rights reserved.This document and the information herein is the property of PhiloWilke Partnership. No part hereof shall be copied, duplicated, distributed, disclosed or used to any extent whatsoever except as expressly authorized by PhiloWilke Partnership. Any Person, firm, or corporation receiving this document, however obtained, shall by virtue hereof, be deemed to have agreed to the forgoing restrictions and that this document will be held in trust and confidence subject only to the private use expressly authorized by PhiloWilke Partnership.Drawing NameProjectIssues / RevisionsPrint Date / Time:Gregory L. Johnson11803WA. Reg. No.C:\Users\ckirch\Documents\Revit_Local_21\222-105 Urgent Care Renton - Preliminary Design (Central) R21_ckirch.rvt1/27/2023 1:03:30 PM01/27/2023A-111222-105Preliminary Floor PlanVelmeir Acquisition Services, LLCRenton -Urgent Care901 S Grady WayRenton, WA 980571/8" = 1'-0"Preliminary Floor Plan108164PNNo. Date Description1 01/27/2023 Preliminary NOT FOR CONSTRUCTION Proposed Finish Slab0' -0"Proposed Finish Slab0' -0"Bottom of Deck -Low Roof16' -0"Bottom of Deck -Low Roof16' -0"Top of Parapet -Low Roof19' -0"Top of Parapet -Low Roof19' -0"Top of Parapet -High Roof24' -0"Top of Parapet -High Roof24' -0"24' - 0"5' - 0"19' - 0"5' - 4"14' - 0"12' - 0"9' - 3"2' - 9"10' - 0"14' - 0"17' - 6"38' - 1 1/4"115' - 4"9' - 0 1/2"9' - 3" 23' - 6"6' - 6"7' - 6"4' - 4"14' - 0"18' - 4"Metal composite wall panelAluminum curtain wall systemExtruded aluminum wall sidingStone masonryExterior lightStone masonrySpandrel glazingSteel tube frameCanopy glazingExisting Grade-0' -6"Average Grade Below Slab-1' -6"Proposed Finish Slab0' -0"Proposed Finish Slab0' -0"Bottom of Deck -Low Roof16' -0"Bottom of Deck -Low Roof16' -0"Top of Parapet -Low Roof19' -0"Top of Parapet -Low Roof19' -0"Top of Parapet -High Roof24' -0"Top of Parapet -High Roof24' -0"24' - 0"5' - 0"19' - 0"7' - 4"12' - 0"9' - 3"2' - 9"12' - 0"9' - 11"22' - 1"44' - 7 1/2"20' - 6"87' - 2 1/2"MIN4' - 6"Metal Composite wall panelPre-manufactured aluminum canopyExtruded aluminum wall sidingSpandrel glazingStone masonryAluminum curtain wall systemExterior lightExisting Grade-0' -6"Average Grade Below Slab-1' -6"Proposed Finish Slab0' -0"Proposed Finish Slab0' -0"Bottom of Deck -Low Roof16' -0"Bottom of Deck -Low Roof16' -0"Top of Parapet -Low Roof19' -0"Top of Parapet -Low Roof19' -0"Top of Parapet -High Roof24' -0"Top of Parapet -High Roof24' -0"24' - 0"19' - 0" 5' - 0"17' - 6"112' - 11 1/2"16' - 0 1/2"13' - 2 1/2"23' - 9 1/2" 11' - 11"8' - 3"24' - 11"14' - 4"12' - 0"2' - 9" 9' - 3"9' - 11"14' - 0" 5' - 4"9' - 11"Stone masonryExtruded aluminum wall sidingMetal composite wall panelMetal wall panel: roof top equipment screenSteel tube frameCanopy glazingSpandrel glazingPre-manufactured aluminum canopySteel door, paintedExisting Grade-0' -6"Average Grade Below Slab-1' -6"Clear8' - 11"Clear8' - 11"5' - 4"36' - 10"5' - 4"48' - 9 1/2"16' - 8"Proposed Finish Slab0' -0"Proposed Finish Slab0' -0"Bottom of Deck -Low Roof16' -0"Bottom of Deck -Low Roof16' -0"Top of Parapet -Low Roof19' -0"Top of Parapet -Low Roof19' -0"Top of Parapet -High Roof24' -0"Top of Parapet -High Roof24' -0"24' - 0"5' - 0"19' - 0"9' - 11"5' - 0"14' - 0"12' - 0"9' - 3"2' - 9"14' - 0" 4' - 4"18' - 4"5' - 0" 33' - 8"57' - 7"10' - 5 1/2" 27' - 0"Metal wall panel: roof top equipment screenSpandrel glazingExtruded aluminum wall sidingMetal composite wall panelStone MasonryPre-manufactured aluminum canopySteel door, paintedExisting Grade-0' -6"Average Grade Below Slab-1' -6"4A-51511275 S. Sam Houston Parkway W.Suite 200 | Houston, Texas 77031832.554.1130 | philowilke.comConsultantsPreliminary Review OnlyNot for Permit or ConstructionBy:Date:P&W Commission NumberSheet NumberCopyright (C) 2023 by PhiloWilke Partnership. All rights reserved.This document and the information herein is the property of PhiloWilke Partnership. No part hereof shall be copied, duplicated, distributed, disclosed or used to any extent whatsoever except as expressly authorized by PhiloWilke Partnership. Any Person, firm, or corporation receiving this document, however obtained, shall by virtue hereof, be deemed to have agreed to the forgoing restrictions and that this document will be held in trust and confidence subject only to the private use expressly authorized by PhiloWilke Partnership.Drawing NameProjectIssues / RevisionsPrint Date / Time:Gregory L. Johnson11803WA. Reg. No.C:\Users\ckirch\Documents\Revit_Local_21\222-105 Urgent Care Renton - Preliminary Design (Central) R21_ckirch.rvt1/27/2023 1:03:42 PM01/27/2023A-201222-105Preliminary ExteriorElevationsVelmeir Acquisition Services, LLCRenton -Urgent Care901 S Grady WayRenton, WA 98057081641/8" = 1'-0"Preliminary East Elevation11/8" = 1'-0"Preliminary North Elevation21/8" = 1'-0"Preliminary West Elevation (Facing Talbot Road South)31/8" = 1'-0"Preliminary South Elevation4081640816408164No. Date Description1 01/27/2023 Preliminary NOT FOR CONSTRUCTION 14 A-51513 A-51512 A-51511 A-5154' - 8"9' - 8"19' - 0"24' - 0"10' - 0" From Building31' - 11 3/4"12' - 8 3/4"Generator EnclosureDumpster Enclosure15' Building SetbackProperty Line17' - 8" Setback at Generator Enclosure20' - 9" Setback at Dumpster Enclosure10' - 6"8' - 9"Proposed Finish Slab0' -0"8' - 7"6"8' - 1"31' - 11 3/4"12' - 8 3/4"low, dense landscapingSteel tube postAdhered stone masonryPre-finished metal coping system8' - 9"10' - 6"Secured metal lattice to support vine growthProposed Finish Slab0' -0"43' - 0"19' - 0"24' - 0"4' - 8" 9' - 8"8' - 7"8' - 1"Pre-finished metal coping systemAdhered stone masonryPremanufactured metal louvered gate, paintedSteel tube postProposed Finish Slab0' -0"8' - 7"31' - 11 3/4"Pre-finished metal coping systemAdhered stone masonrySecured metal lattice to support vine growthlow, dense landscapingProposed Finish Slab0' -0"43' - 0"19' - 0"24' - 0"8' - 1"8' - 7"Pre-finished metal coping systemAdhered stone masonrySecured metal lattice to support vine growthlow, dense landscapingBottom of Deck -Low Roof16' -0"Top of Parapet -Low Roof19' -0"Top of Parapet -High Roof24' -0"5' - 0"3' - 0"8' - 0"8' - 3"24' - 11"1' - 4 1/2" +/-Metal wall panel: roof top equipment screenSteel tube frameMEP specified rooftop equipment on 30" +/- curb11275 S. Sam Houston Parkway W.Suite 200 | Houston, Texas 77031832.554.1130 | philowilke.comConsultantsPreliminary Review OnlyNot for Permit or ConstructionBy:Date:P&W Commission NumberSheet NumberCopyright (C) 2023 by PhiloWilke Partnership. All rights reserved.This document and the information herein is the property of PhiloWilke Partnership. No part hereof shall be copied, duplicated, distributed, disclosed or used to any extent whatsoever except as expressly authorized by PhiloWilke Partnership. Any Person, firm, or corporation receiving this document, however obtained, shall by virtue hereof, be deemed to have agreed to the forgoing restrictions and that this document will be held in trust and confidence subject only to the private use expressly authorized by PhiloWilke Partnership.Drawing NameProjectIssues / RevisionsPrint Date / Time:Gregory L. Johnson11803WA. Reg. No.C:\Users\ckirch\Documents\Revit_Local_21\222-105 Urgent Care Renton - Preliminary Design (Central) R21_ckirch.rvt1/27/2023 1:03:45 PM01/27/2023A-515222-105Preliminary Site Details- Dumpster EnclosureVelmeir Acquisition Services, LLCRenton -Urgent Care901 S Grady WayRenton, WA 980571/4" = 1'-0"Preliminary Enlarged Plan - Enclosure11/4" = 1'-0"Preliminary North Elevation - Enclosure111/4" = 1'-0"Preliminary East Elevation - Enclosure121/4" = 1'-0"Preliminary South Elevation - Enclosure131/4" = 1'-0"Preliminary West Elevation (Facing Talbot Road South) - Enclosure140816408164081640816408164PNNo. Date Description1 01/27/2023 Preliminary NOT FOR CONSTRUCTION1/4" = 1'-0"Preliminary Cross Section at Rooftop Screening408164 11275 S. Sam Houston Parkway W. Suite 200 | Houston, Texas 77031 832.554.1130 | philowilke.com Consultants Preliminary Review Only Not for Permit or Construction By: Date: P&W Commission Number Sheet Number Copyright (C) 2023 by PhiloWilke Partnership. All rights reserved. This document and the information herein is the property of PhiloWilke Partnership. No part hereof shall be copied, duplicated, distributed, disclosed or used to any extent whatsoever except as expressly authorized by PhiloWilke Partnership. Any Person, firm, or corporation receiving this document, however obtained, shall by virtue hereof, be deemed to have agreed to the forgoing restrictions and that this document will be held in trust and confidence subject only to the private use expressly authorized by PhiloWilke Partnership. Drawing Name Project Issues / Revisions Print Date / Time: Gregory L. Johnson 11803WA. Reg. No.C:\Users\ckirch\Documents\Revit_Local_21\222-105 Urgent Care Renton - Preliminary Design (Central) R21_ckirch.rvt2/22/2023 2:08:43 PM 02/22/2023 A-601222-105 Preliminary Exterior Perspective Renders Velmeir Acquisition Services, LLC Renton - Urgent Care 901 S Grady Way Renton, WA 98057 N.T.S.Preliminary Exterior - Approaching Urgent Care 1 N.T.S.Preliminary Exterior - Approaching Emergency Drop-Off 3N.T.S.Preliminary Exterior - Talbot Road South Facing Northeast 13 N.T.S.Preliminary Exterior - Talbot Road South Facing Southeast 11 No. Date Description 1 01/27/2023 Preliminary NOT FOR CONSTRUCTION