HomeMy WebLinkAboutC_Response Letter_121217_V3O December 12, 2017 Development Engineering Division City of Renton 1055 S. Grady Way Renton Washington 98057 Taco Bell 4225 NE 4th Street Renton, Washington 98059 Ms. Fowler, GPD Group, Professional Corporation is in receipt of the corrections dated 11/06/2017 for the above- referenced project. We are addressing each comment as follows: Sheet T-001 1. If any utility easements for the city are being created or released, please provide documentation for review and/or start the release process. Response: A proposed water easement has been added to sheet C-110. Sheet C-101 1. Additional Comment Received from 2nd Submittal: Dimension Pipe Removal. Response: Response: Sheet C-101 has been updated to show pipe removal dimension. Sheet C-110 1. Additional Comment Received from 2nd Submittal: Water main easement is required to include the fire hydrant and the water main to the water meters. The water service line does not need to be included in an easement. Response: A proposed water easement has been added to plan sheet C-110. Sheet C-121 1. Additional comment received from 2nd submittal: ADA accessible routes must be a minimum of 4- ft wide. 5-ft preferred. Response: All proposed ADA routes have a minimum width of 4-ft. Taco Bell – 4225 NE 4th Street 12 December 2017 Sheet C-141 1. Show removal of the existing hydrant service line and fitting. Identify new fittings for relocated service line. Response: Plans have been updated to show removal of existing hydrant and new hydrant location. Proposed fire hydrant fitting keynotes have also been added to the plans. 2. As proposed, the areas draining to the rain garden are required to be analyzed as bypass area from the existing conveyance system in accordance with section 1.2.3E of the City of Renton Amendments to the 2009 KCSWDM. The applicant will need to include a discussion in the TIR showing compliance with all criteria outlined in the manual. Alternatively, the release from the rain garden can be routed to the existing conveyance system. Response: A discussion has been added to the TIR describing the proposed sites compliance with section 1.2.3.2.E of the City of Renton Amendments to the King County Surface Water Design Manual. 3. Due to the high-use site, enhanced water quality is required prior to the downstream connections. Response: A discussion has been added to the TIR describing the site’s compliance with section 1.2.8.1 Exception 4 of the City of Renton Amendments to the King County Surface Water Design Manual. 4. Additional comment received from 2nd submittal: Identify new fittings for relocated fire hydrant. Response: Sheet C-141 has been updated to include fire hydrant fitting keynotes. 5. Additional comment received from 2nd submittal: Provide a curved sidewalk around the fire hydrant. Minimum 4-ft in width. 5-ft preferred. Response: The plans have been updated to include a curved walk around the fire hydrant. 6. Additional comment received from 2nd submittal: Water main easement is required to include the water main to the water meters. The water service line does not need to be included in an easement. Response: A proposed water easement has been added to plan sheet C-110. 7. Irrigation meter and double check valve assembly per standard plan 340.8. Response: Plans have been updated to require a double check valve assembly per standard plan 340.8. Taco Bell – 4225 NE 4th Street 12 December 2017 Sheet C-504 1. Additional comment received from 2nd submittal: Irrigation meter and double check valve assembly per standard plan 340.8. Response: Standard Plan 340.8 has been added. Sheet C-506 1. Show the inlet from the roof drains. Response: Sheet C-121 has been updated to show the proposed drainage route from the roof downspout. Please note that due to City of Renton comments, some page numbers have been updated. Landscape Plans: Sheet L1.0 1. Update [rock channel protection] to match civil plans: Response: The hatch has been updated to match the civil plans. Sheet IR1.0 1. Update [rock channel protection] to match civil plans: Response: The hatch has been updated to match the civil plans. Drainage Report 1. The proposed site is a high-use site and is therefore subject to enhanced water quality treatment. The existing water quality facility was designed using the basic water quality menu. Installation of additional water quality measures will be required. For example, a stormfilter with CSF leaf compost media (see section 6.5.5 of the City of Renton Amendments to the 2009 KCSWDM). Response: A discussion has been added to the TIR describing the sites compliance with section 1.2.8.1 Exception 4 of the City of Renton Amendments to the King County Surface Water Design Manual. 2. High use site & subject to enhanced wq standards. The existing wetpool was designed using the basic wq manual. Response: A discussion has been added to the TIR describing the Taco Bell – 4225 NE 4th Street 12 December 2017 sites compliance with section 1.2.8.1 Exception 4 of the City of Renton Amendments to the King County Surface Water Design Manual. 3. Originally approved as a bank. Change to a restaurant results in the site being high use and requiring enhanced treatment. Response: A discussion has been added to the TIR describing the sites compliance with section 1.2.8.1 Exception 4 of the City of Renton Amendments to the King County Surface Water Design Manual. If you require any additional information or have any questions, please contact me at 330-572-3532 or email at rdarwish@gpdgroup.com. Sincerely, Rafia Darwish, EI, LEED AP BD+C Project Coordinator GPD Group