Loading...
HomeMy WebLinkAboutMFP23001714.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Minor Franchise Permit: MFP23001714 IVR Number: 23001714 Permit Information Permit Name: Puget Sound Energy - Electric Address/Location:04/03/2023Application Date:1723059136Parcel Number: 625 WILLIAMS AVE S Permit Type:04/19/2023Issue Date:Franchise Permit Work Class:04/18/2024Expiration Date:Minor Utility Job Number: 105102371Franchise Type:Electric Description: Puget Sound Energy Electric CREW (AND CUSTOMER) TO CUT OPEN EXISTING SIDEWALK AND ROAD TO LOWER (2) 6" CONDUITS. CREW WILL REMOVE OLD CABLE AND PULL THROUGH NEW CABLE, APPROX 50' X 5' 6' WORK PIT NEEDE SHORING IS REQUIRED. WORK PIT TO EXTEND 25FT NE AND 25FT SW OF STORM DRAIN CONFLICT. Contacts Name Address PhoneTypeBilling Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031ApplicantX Vicki Henson Potelco Inc 8001 212th St S Kent, WA 98032 B: (253) 863-0484Contractor Business License Number: 5109Electrical Contractor: POTELI*344O4 Construction Contractor: POTELI*227PL Puget Sound Energy Inc 10885 NE 4th Street, PSE08-N08 Bellevue, WA 98009 B: (888) 225-5773Emergency Contact GMD RENTON LLLP 520 PIKE ST # 1010 SEATTLE , WA 98101 Owner Corrie Rydberg Puget Sound Energy 3702 71st Ave W University Place, WA 98466 C: (253) 905-5031Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering PLEASE SEE ATTACHED POTELCO, INC 6905 S 228TH ST KENT, WA 98032 105102371 625 Williams Ave S (253) 208-9480jenny chau MFP23001714 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 4/19/2023 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) CORRIE RYDBERG 625 Williams Ave S Renton WA 98057 USAP031J01P02WELLS AVE S22BUSSTOPBUSSTOPWIL L IAMS AVE S121312121212111112111111111211111111111111111111191112111112WILL IAMS AVE SS GRADY WAYS GRADY WAYS GRADY WAYS GRADY WAYc-curbc-curbc-curbc-curbBUSSTOPARRW-BRD RIGHT LANE CLOSED AHEAD W20-5RW4-2LROAD WORK AHEAD W20-1350'350'350'S/WCLOSEDR9-9CROSS HERESIDEWALK CLOSEDAHEADBUSINESS(ES)/RESIDENT(S)WILL BE INFORMED OF POSSIBLETEMPORARY DRIVEWAY CLOSUREBUSINESS DRIVEWAYCLOSED.ENTER/EXIT FROMDRIVEWAY FURTHER WESTON S GRADY WAY.C/W CLOSED CW-CLSDDETOUR PED-DETDIP2DIP1V0110 0 'ROADWORKAHEADW20-1W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4100'100'100'TALBOT RD SDETOURM4-9bR9-11SIDEWALKCLOSEDAHEAD1515ON E W A Y TEMPORARY TRAFFIC CONTROL PLANNSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVSafaa Al Neema(425) 398-6077safaa.alneema@pse.com1 OF 3625 Williams Ave S, Renton, WA 980570 10510237103/02/2023Puget Sound EnergyTraffic Control Supervisor:Safaa Al NeemaCard No. 012611Card Exp. 10/31/2024Safaa.alneema@pse.com(425)398-6077Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.WORK PIT28" TRAFFIC CONETRAFFIC FLOWSIGN LOCATIONLEGENDCHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYROW ROW MFP23001714 625 Williams Ave S Renton WA 98057 USAP031J01P02WELLS AV E S22POLICEUPOBUSSTOP BUSSTOPWIL L IAMS AVE S121312121212111112111111111211111111111111111111191112111112WILLIAMS AVE SS GRADY WAYS GRADY WAYS GRADY WAYS GRADY WAYc-curbc-curbc-curbc-curbBUSSTOPARRW-BRD M6-2RIGHT LANE CLOSED AHEAD W20-5RW4-2LROAD WORK AHEAD W20-1350'350'350'S/W CLOSEDR9-9S/WCLOSEDR9-9CROSS HERESIDEWALK CLOSEDAHEADBUSINESS(ES)/RESIDENT(S)WILL BE INFORMED OF POSSIBLETEMPORARY DRIVEWAY CLOSUREMOVE BUS STOP 150' WEST.KING COUNTY METRO WILL BECONTACTED AT 206-477-1150 FIVE DAYSIN ADVANCE OF SCHEDULED DATE.C/W CLOSED R9-3DETOUR M4-9bDIP2DIP1V01W20-7ABEPREPAREDTOSTOPW3-410 0 ' 10 0 'RIGHT LANECLOSEDAHEADW20-5RW1-4L100 ' 10 0 ' 10 0 'ROADWORKAHEADW20-1W20-7ABE PREPARED TO STOP W3-4350'350' W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4100'100'100'TALBOT RD SDETOURM4-9bR9-11SIDEWALKCLOSEDAHEADW20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4350'350'350'1515ON E W A YProject Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVSafaa Al Neema(425) 398-6077safaa.alneema@pse.com2 OF 3625 Williams Ave S, Renton, WA 980570 10510237103/02/2023Puget Sound EnergyTraffic Control Supervisor:Safaa Al NeemaCard No. 012611Card Exp. 10/31/2024Safaa.alneema@pse.com(425)398-6077Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONELEGENDWORK PITTRAFFIC FLOWSIGN LOCATIONFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPCHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYROW ROW TEMPORARY TRAFFIC CONTROL PLANNSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040MFP23001714 625 Williams Ave S Renton WA 98057 USAP031J01P02WELLS AV E S 22POLICEUPOBUSSTOP BUSSTOP121312121212111112111111111211111111111111111111191112111112WILL IAMS A VE SS GRADY WAYS GRADY WAYS GRADY WAYS GRADY WAYc-curbc-curbc-curbc-curbBUSSTOPARRW-BRD RIGHT LANE CLOSED AHEAD W20-5RW4-2LROAD WORK AHEAD W20-1350'350'350'CROSS HE RE SIDEWALK CLOSED AHEADV01W20-7ABEPREPAREDTOSTOPW3-4100 ' 100 ' 100 'ROADWORKAHEADW20-1W20-7ABE PREPARED TO STOP W3-4350'350' W20-7AROADWORKAHEADW20-1 BEPREPAREDTOSTOPW3-4100'100'100'TALBOT RD SDETOURM4-9bR9-11SIDEWALKCLOSEDAHEADW20-7AROADWORKAHEADW20-1BEPREPAREDTOSTOPW3-4350'350'350'1515ON E W A Y DETOUR M4-9bR9-11SIDEWALK CLOSED AHEADC/WCLOSEDR9-3DETOURM4-9bC/W CLOSED R9-3Project Address:PagePSEPUGETSOUNDENERGYDesigner:Job #REVSafaa Al Neema(425) 398-6077safaa.alneema@pse.com3 OF 3625 Williams Ave S, Renton, WA 980570 10510237103/02/2023Puget Sound EnergyTraffic Control Supervisor:Safaa Al NeemaCard No. 012611Card Exp. 10/31/2024Safaa.alneema@pse.com(425)398-6077Notes:1. All signs and spacing to conform to theMUTCD and City of Renton standards.2. All sidewalks, driveways, exits and egressesshall be completely clear unless otherwise indicated.3. Channelizing devices are 28" traffic cones.Use traffic drums (barrels) with steady burningType C lights on all State State Routes and Hwys.4. Sign size can be a minimum of 36" x 36" andshall not obstruct pedestrian access.5. Crew is required to leave a minimum of 10' fortraveling lane width.6. Alert affected residents and businesses.7. Work to take place between 9 a.m. and 4 p.munless otherwise specified. All work for arterialsand major roadways will be from 9 a.m. to 3 p.m.28" TRAFFIC CONELEGENDWORK PITTRAFFIC FLOWSIGN LOCATIONFLAGGERUNIFORMEDPOLICE OFFICERPOLICESTOPCHEVRONARROW BOARDWORK VEHICLE/FLASHING LIGHTSRIGHT OF WAYROW ROW TEMPORARY TRAFFIC CONTROL PLANNSIGN SPACINGMPH60/6545/5535/403025"X"1000'500'350'200'100'CHANNELIZATIONDEVICE SPACINGMPH55/7035/4525/30TAPER403020TANGENT806040MFP23001714 620 900 615 607 S G R A D Y W AY 317589-166044 T87290 (100T) T87289 (Soli) 317592-165032 300 kVA 208V (ABC) STORM DRAIN CROSSING SET CONDUIT TO EL 25.73 MAINTAIN 1FT VERTICAL CLEARANCE FROM BOTTOM OF STORM DRAIN. 317614-166057 T87291 GRA17317595-166048 750 kVA 277/480V (ABC) 1000kVA 120/208V (ABC) 317614-166057 30 kVA 208V (ABC) 317623-166053 T87292 (100T) SLAG6832 317621-166063 317621-166052 150 kVA 208V (ABC) 80' R/W 60' R/W CUSTOMER PROVIDED 50' X 5' WORKPIT **SHORING REQUIRED** EXISTING 6" SPARE CONDUIT EXISTING 6" SPARE CONDUIT PSE INSTALL ±20 1- 6" SCH'L 80 AT EL 25.73 1' MIN CLEARANCE FROM STORM DRAIN 6" SPARE TO BE MODIFIED FIRST PSE INSTALL ±20 1- 6" SCH'L 80 AT EL 25.73 1' MIN CLEARANCE FROM STORM DRAIN MODIFY AFTER SPARE CUSTOMER PROVIDED 11'X11' W/ 6" BEDDING OF 5/8" CRUSHED ROCK EXISTING 4" CONDUIT EXISTING 6" CONDUIT EXISTING 6" CONDUIT PSE INSTALL ±485' OF 750KCMIL FEEDER CABLE SITE PLAN N Vicinity Map 47.474021, -122.207247 Owner / Developer Contact Info officeATTN: GMD Renton LLLP 520 Pike St Suite 1010 Seattle WA. 98101 Steve Dymoke 206-745-6464 ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE GRA-17 10/18/2022 190 232 207 27.28 27.28 27.28 217.28 259.28 234.28 GAS PHONE CABLE TV N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Perm. Service Relocation Removal Temporary Job Order Distribution HP Svc/MSA POWER GENERAL NOTES - COMMERCIAL PROJECT 8. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. Inclement weather conditions may cause delays in construction times and dates. 1. 2. 3. 4. 5. 6. 7. 9. 11. 10. PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" E-Mail: Cell Phone: Project Manager Contact Information: Manager:Jenny Chau 253-208-9480 jenny.chau@pse.com SCALE: 1" = 50'105102371THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL 811 TWO BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Jenny Chau 253-208-9480 2/28/2023 Ray Reynolds 253-262-7409 2/28/2023 N/A N/A N/A Ray Reynolds -2/28/2023 RW-_____RENTON WATERSHED PERM POWER INSTALL NEW 3Ø PADMOUNT TRF, LOWER AND REPLACE FEEDER 625 WILLIAMS AVE S RENTON, WA. 98057 N/A N/A N/A 105102371 AS NOTED 1 OF 1 KING N/A N/A CSPSKEPM SW-17-23-5 N/A N/A 2305E072SE 2305E076 2305E072 GRA-17 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Service Stubs 105102371 N/A N/A 513600442 N/A CUSTOMER DEVELOPMENT NOTES: A PRE CONSTRUCTION MEETING IS REQUIRED WITH YOUR PROJECT MANAGER PRIOR TO STARTING ANY SITE WORK. CUSTOMER IS RESPONSIBLE FOR ALL TRENCHING, SELECT BACKFILL, COMPACTION & RESTORATION PER PUGET SOUND ENERGY STANDARDS & LOCAL MUNICIPALITY. **DEVELOPER NEEDS TO FOLLOW ALL TRENCH DETAILS ON SELECT BACKFILL** CUSTOMER IS RESPONSIBLE FOR THE FOLLOWING: VAULTS & WORK PITS. -REQUIRED TO PROVIDE 11' X 11' WORK PIT & 6" BEDDING OF 5/8" MINUS CRUSHED ROCK AT V01 -REQUIRED TO PROVIDE 50’ X 5' WORKPIT WITH SHORING AT STORM DRAIN CROSS TRENCHING & CONDUIT. -SEE CABLE/CONDUIT TABLES FOR LENGTHS AND INSTALL -REQUIRED TO PROVIDE AND INSTALL A 3/8" NON-POLY PULL ROPE IN ALL CONDUITS. JOB SITE READINESS. -JOB SITE NEEDS TO BE 100% READY FOR INSPECTION 5 BUSINESS DAYS PRIOR TO CONSTRUCTION DATE. -ALL WORK IN RIGHT OF WAY MUST BE COORDINATED WITH PROJECT MANAGER AND LOCAL MUNICIPALITY. -ALL TRENCH, AND LOCAL ELECTRICAL MUNICIPALITIES AKA "L&I, CITY", INSPECTIONS MUST BE COMPLETED 5 BUSINESS DAYS PRIOR TO SCHEDULED CONSTRUCTION DATE. -REQUIRED TO OPERATE AND PROVIDE EQUIPMENT TO PUMP OUT WATER FOR WORK PITS, VAULTS & TRENCH AT ALL TIMES. -REQUIRED TO HAVE EXCAVATION EQUIPMENT AND BE ON SITE THE DAY OF CONSTRUCTION TO COMPLETE BACKFILLING. -IF A SECOND INSPECTION IS REQUIRED, ADDITIONAL FEE'S WILL BE APPLIED. -PLEASE REVIEW THE CITY OR KING COUNTY TRENCHING REQUIREMENTS UNDER THE PERMIT. -IF A PRE-CON IS REQUIRED BY THE CITY, COUNTY OR W.S. DOT A PSE PROJECT MANAGER WILL SET-UP AND SCHEDULE A MEETING WITH THE MUNICIPALITY BEFORE ANY EXCAVATION OR INSTALLATION BEGINS. SITE SPECIFIC NOTES AT P01: 317589-166044 EXISTING: -EXISTING 2022 55' CL-2 POLE TO REMAIN -REMOVE SOLID BLADE CUTOUT TO DE-ENERGIZE CABLES AØEIQ276, BØEIQ277, CØEIQ278 -RE-ENERGIZE CABLES AØEJN303, BØEJN304, CØEJN305 AFTER CONDUITS HAVE BEEN LOWERED AT P02: 317614-166057 EXISTING: -EXISTING UNK YR 40' CL-UNK POLE TO REMAIN -REMOVE SOLID BLADE CUTOUT TO DE-ENERGIZE CABLES AØEIQ276, BØEIQ277, CØEIQ278 -RE-ENERGIZE CABLES AØEJN303, BØEJN304, CØEJN305 AFTER CONDUITS HAVE BEEN LOWERED AT V01: 317595-166048 : NEW: -REMOVE EXISTING 750kVA 277/480V TEMP TRF -REMOVE TEMP PAD -INSTALL (1) 7' X 7' X 4' VAULT W/ GRNDS PER STD 6045.5000 (PM312D) -INSTALL VAULT COVER 7' X 7' X 6'-2" , 24 X 60" ACCESS, 8'-10' (MID: 7918000) -INSTALL CABLE SUPPORT LADDER (MID: 9997916) -INSTALL (1)1000 KVA PADMOUNT TRF (MID: 6258350) -REROUTE EXISTING CABLES AØEJG496, BØEJG497, CØEJG498 -INSTALL (3) 12kV ELBOW KIT PER STD 6041.1000 (ELB10J) -INSTALL (16) #501 TO 750KCMIL CONNECTOR BARS (MID: 7651003) -INSTALL (4) #2 TO 500KCMIL CONNECTOR BARS (MID: 7651000) -INSTALL (72) MOUNTING BOLT KITS (MID: 7651008) -INSTALL GRID # -CONNECT 17-RUN OF CUSTOMER OWNED, INSTALLED, & MAINTAINED 600KCMIL SVC -CONNECT 1-RUN OF CUSTOMER OWNED, INSTALLED, & MAINTAINED 250KCMIL SVC AT M01 "HSE" -POTELCO TO INSTALL (145) METERS ON 4000A PANEL AT M02 "STANDBY SVC" -PSE METER DEPT TO INSTALL (1) METER ON 200A PANEL AT M03 "MDP" -PSE METER DEPT TO INSTALL (1) METERS ON 1600A PANEL SPAN SPECIFIC NOTES -SEE TABLES AND ONE-LINES FOR INSTALL Installed at site: Grid Number: kVA Rating: TRANSFORMER INSTALLATION (PM) Company ID#: Primary phase connected to: Tested Secondary Voltage Material ID#: Foreman to redline the following information 1000kVA 120/208v 6258350 V01 317595-166048 CONDUIT DIAGRAM SCALE: NTS Vault & Equipment Table Work Location Grid Number Vault Size & Cover Type & Size Equipment In Vault Primary Bushings Transformer ID Numbers (Company ID) ASBUILT INFORMATION Foreman-CompleteLBDC V01 317595-166048 PM3P12D (7'x7'x6.167') PAD-3P-12-1 20/208-1000 (1000 kVA) 3 Primary Cable & Conduit Table (Foreman to Complete) LOCATION CONDUIT PRIMARY CABLE QTY OF LUBE (gal.)AS BUILT INFORMATION From To Size (in) Qty Design Length (ft) Actual Length (ft) TYPE BENDS PULL (lbs) PULL Rev (lbs) Cable Size Design Length (ft) Actual Length (ft) CABLE NUMBERS MANUFACTURING INFORMATION FOR FEEDER CABLE ONLY Check applicable box DB120 HDPE SCH 80 90°45°22°11°A B C Manufacturer Compound Year Tape CN #4/0 NEU Design As Built Actual Amount Installed (Conduit & Cable) DIP1 DIP2 6"2 20'X 0 0 0 0 0 0 P01 P02 EXISTING 6" CONDUIT 902.54 902.54 FEEDER 750 UG 485'EJN303 EJN304 EJN305 Removed at site: Grid Number: kVA Rating: Foreman to redline the following information TRANSFORMER REMOVAL Company ID#: Primary phase connected to: Tested Secondary Voltage V01 317595-166048 750kVA CABLE DIAGRAM SCALE: NTS CUSTOMER OWNED AND INSTALLED SECONDARY WIRE TABLE BLDG.# OF METERS SOURCE # OF RUNS WIRE SIZE REMARKS 1 145 V01 12 600KCMIL - 1 1 V01 1 250KCMIL - 1 1 V01 5 600KCMIL - ALL CUSTOMER-OWNED WIRE MUST BE INSTALLED ACCORDING TO THIS TABLE JOB SITE LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: 778 SQ FT PER UNIT 4000AMP ELECTRIC 459KW 321A 2.0% 0.7% 00 1"2" 00 50'100' DEDICATED FACILITIES SITE SPAN ADDITIONAL REMARKS LABOR UNITS #FROM TO FOOTAGE V01 ---TFR UPGRADE DUE TO # OF RUNS 3-12 TOTAL FT=## ABANDONED / REMOVE / REPLACED CABLE SCHEDULE CABLE NO. SAP EQUIP LOCATIONS CABLE (LF) EST EXISTING CABLE MFG. NAME EXISTING CABLE MFG. DATE CABLE REPLACED?FROM TO EIQ276 1700358 P01 P02 485' EIQ277 1700359 485' EIQ278 1700360 485' TOTAL 1455' FAULT CURRENT TABLE 3Ø PM TRANSFORMERS (208Y/120V) 120V WINDINGS 208V WINDINGS LOCATION SIZE R/X MIN. %Z FAULT CURRENT MIN. %Z FAULT CURRENT V01 1000KVA 0.1 --5.30 52,400 AMPS CIRCUIT FEET ADDED: 485' CIRCUIT FEET REMOVED: 485' MFP23001714 RESTORATION PER CITY OF RENTON STANDARDS 105102371FLOW DIRECTION LAY 8" BOTTOM SKIRT ON TOP OF NATIVE SOIL, SECURE WITH PEA GRAVEL BAGS (MID 9995692). 6' 3' 8" TECHNIQUES FOR EROSION AND SEDIMENT CONTROL SILT FENCE DETAIL Not to Scale 0150.3200 Communications Primary Power Cables or Conduit Excavated Dirt Pile ROADSIDE Final Grade 24" Min 12" Min Separation 36" Min Cover 48" Max Backfill (No rocks over 10" diameter) Separation 12" Min Gas 4" Sand Bedding 32" Typical (Power, Gas, and Communications) JOINT TRENCH DETAIL Primary-Mainline Gas & Communications (NTS) Separation 12" Min 6" or 12" Min Sand Shading after Compaction - A 6" layer of sand is allowed when excavated native material contains rocks no larger than 8" in diameter. Trench and backfill requirements for primary electric line extension trenches (No PSE gas) - A 12" layer of sand is required when excavated native material contains rocks up to 10" in diameter. SPLICE PIT DETAIL SCALE: NONE 2" Excavation - 20 cubic yards 10'-0" 7'-0" 8'-0" 8" 6'-2" SIDE VIEW 6'-6"Crushed 6" Rock 11' 11' TOP VIEW 5'-6" 7'-0" 6045.5000Not to scale VAULT & EXCAVATION DETAIL JOB SITE OVERHEAD CIRCUIT MAP(D2305E088) SCALE: 6" =1 MILE UNDERGROUND MAP(D2305E067) SCALE: NTS JOB SITE COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR PSE EQUIPMENT CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 3' MIN 3' MIN 3' MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA 6775.0035 Not to scale PM XFMR VAULT B-FLY DETAIL (V01) SCALE: NONE Customer Owned Services Prop 4" (J01)FRONT OF TRANSFORMER UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP Jenny Chau 253-208-9480 2/28/2023 Ray Reynolds 253-262-7409 2/28/2023 N/A N/A N/A Ray Reynolds -2/28/2023 RW-_____RENTON WATERSHED PERM POWER INSTALL NEW 3Ø PADMOUNT TRF, LOWER AND REPLACE FEEDER 625 WILLIAMS AVE S RENTON, WA. 98057 N/A N/A N/A 105102371 AS NOTED 1 OF 1 KING N/A N/A CSPSKEPM SW-17-23-5 N/A N/A 2305E072SE 2305E076 2305E072 GRA-17 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A MFP23001714