HomeMy WebLinkAboutMFP23001830.pdfDEPARTMENT OF COMMUNITY
AND ECONOMIC DEVELOPMENT
Minor Franchise Permit: MFP23001830
IVR Number: 23001830
Permit Information
Permit Name: P.103130
Address/Location:04/07/2023Application Date:1923059062Parcel Number: 955 LIND AVE SW
Permit Type:05/01/2023Issue Date:Franchise
Permit Work Class:04/30/2024Expiration Date:Minor Utility
Job Number: P.103130Franchise Type:Telephone
Description: Lumen to access MH110, MH111, MH112, and HH201
Contacts
Name Address PhoneTypeBilling
Austin Sweeney
Century Link
23315 66th Ave S
Kent, WA 98032
C: (253) 766-7549ApplicantX
Stephen Neumann
Fibe Solutions
604 W Meeker St., Suite 103
KENT, WA 98032
C: (425) 753-1916Applicant
Jesse Patjens
CenturyLink / Lumen
23315 66th Ave S
Kent, WA 98032
Contact
Austin Sweeney
Century Link
23315 66th Ave S
Kent, WA 98032
C: (253) 766-7549Contact
Kim Parker
QWest Corporation
931 14th St, Suite 1000A
Denver, CO 80202
B: (303) 992-0752Contact
Michael Smith
North Sky Communications
21320 84th Ave S
Kent, WA 98032
C: (206) 305-5881Contractor
Business License Number: 36846Construction Contractor: NORTHSC857Q4
CITY OF RENTON ROW 1055 S Grady Way
Renton, WA 98057-3232
Owner
QWest/Century Link - Billing 23315 66th Ave S
Kent, WA 98032
Specialized
Billing
General Conditions & Signature
Permission is hereby given for the work described on this permit according to the conditions hereon and according to the
approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton.
Ÿ
This permit and plans must be posted at the job site at all times.Ÿ
I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to
Renton Trench Restoration and Street Overlay Requirements.
Ÿ
Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY
work in the Right of Way.
Ÿ
Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ
In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010)
(Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission
pipeline company prior to performing any construction or excavation activities. This requirement to consult with the
transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122.
Ÿ
(Date)(Signature)
Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
DEPARTMENT OF PUBLIC WORKS
Page 1 of 3 | Published: 10/27/2021
Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380
Website: rentonwa.gov
TRAFFIC CONTROL PLAN APPLICATION
Published: 10/27/2021
TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION
FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK.
The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control
plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted
within the city's right-of-way.
1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents.
2. The following items are all required for submittal of the TCP Application:
☐Electronic Copy of the TCP Application
☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall:
Include map(s) showing the location of the project and work area.
Be legible lettering and clear, contrasting, symbols of viewing or printing.
Must indicate street names, and north arrow and scale.
Types of plans required:
o Work hour plan – show all mobility impacts during construction hours.
o Non-work plan - show all mobility impacts after work hours when limited or no work is
happening in the right-of-way (ROW), if applicable.
o Changing construction phases – show construction sequence and each construction phase
change even if the traffic control is not modified, if applicable.
o Pedestrian access/detour plan, if applicable.
- Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the
Evergreen Safety Council.
3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].”
Project Name: Permit #:
Site Address:
Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________
Construction Company:
Contact Name: Phone/Cell: _________________________
Business Address: City/State: Zip:
Description of Work:
Approval By: _________________________________________________ Date:____________________
Transportation Engineering
Northsky Communications
Tawnya Longfellow
22517 88th ave S Kent/WA 98031
P.103130
955 Lind Ave SW
5/7/23 6/7/23
4256157121
Lumen to access MH110, MH111, MH112, and HH201
MFP23001830
Monday - Friday 8:00AM - 3:00PM
Scott Warlick CED 5/1/2023
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 2 of 3 | Published: 10/27/2021
PERMIT HOLDER AGREES TO ALL THE FOLLOWING:
Must have approved Traffic Control Plan (TCP) prior to commencing the work.
Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time,
with the least possible inconvenience or delay to pedestrians.
WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the
traveled way.
Comply with all traffic regulations of the City of Renton and the State of Washington.
Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street
and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control
Devices.
Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures.
Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public
transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends
and holidays) prior to starting any work.
Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum
of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a
temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a
minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140
with any questions.
Any lane or street closures not in conformance with the approved traffic control plan and/or without notification
of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at
thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes.
Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all
costs of defense and attorney’s fees incurred in defending against same, arising from and related to
implementation of the approved traffic control plans including claims arising from towing of private vehicles and
the acts of the Permit Holder’s agents and employees.
The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in
such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable
attorney’s fees and litigation costs incurred resulting from such claim.
In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for
legal counsel chosen by the City to defend against same.
Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or
pedestrian safety or travel.
All permit conditions shall be met.
NOTES:
Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council.
Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD)
and shown by a traffic control plan layout or reference to WSDOT.
Approved Temporary Traffic Control Plan must be at the work site during work hours.
Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or
walkway is impeded to safely redirect pedestrians around a work zone.
Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery
road conditions during work and non-work hours.
Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company
logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous
place on the vehicle or equipment.
Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document.
Page 3 of 3 | Published: 10/27/2021
In the case of Temporary No Parking Zones, all the following apply in addition to previous:
Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for
vacate parking or curb lane usage.
Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block
seventy-two (72) hours in advance of effective date and time.
The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the
project site.
Temporary traffic control devices must be removed immediately when work is done or no construction activities
are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555
NE 2nd Street).
I certify that the information on this application and within the submittal documents are accurate to the best of my
knowledge and I acknowledge all the requirements on this application.
Applicant’s Signature Date
Applicant’s Name (Print)
Austin Sweeney
Austin Sweeney 4/7/2023
MFP23001830
Additional approval
will be needed from
BNSF for work in
their ROW
LIND AVE SW
S
W
1
0
T
H
S
T
DWY
DWY DWY
DWYDWYDWYDWY
TRAFFIC CONTROL PLAN
JOB # P.103130.C.45
PERMIT #
Legend
CONES
WORK TRUCK
SPOTTER
Arrowboard (Chevron)
HANDHOLE
WORK AREA
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
Date:3/20/23 Author:Darlene Durr, Traffic Control Supervisor Project:P.103130.C.45
CERT:TCS # 011915 LUMEN:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be DETERMINED BY CITY, COUNTY AND/OR WSDOT.
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #011915, darlene.durr@hotmail.com
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60
Approved 3/20/2023Darlene Durr
TCS # 011915
Phone 253-737-5198darlene.durr@hotmail.com
_______________________Darlene Durr
NOT TO SCALE
NOTE ALL LANE WIDTHS ARE ESTIMATES; FOR ACCURANCY, MEASURE IN FIELD PRIOR TO
WORK.
REFER TO CHARTS FOR DEVICE SPACING,
SIGNAGE SPACING, SIGN SIZE, BUFFER
SPACING AND TAPER LENGTHS.ROADWORKAHEADS
HH 201
ROADWORKAHEADNComments:
THIS IS TO ACCESS MH 201.
THIS IS A RIGHT LANE CLOSURE.SIDEWALK IS ACCESSIBLE.
SPOTTER WILL ASSIST AT WORK AREA.
DRIVEWAYS REMAIN ACCESSIBLE AT WORK AREA.WORK AREA
10' X 400'
SPEEDLIMIT
30
LIND AVE SW @ SW 10TH ST
HH 201 ACCESS
RIGHT LANE CLOSURE
200'
200'
200'
200'MERGING TAPER150'RIGHT LANECLOSEDAHEADwww.invarion.com
MFP23001830
DWY
DWY
LIND AVE SW
S
W
G
R
A
D
Y
W
A
Y
S
W
G
R
A
D
Y
W
A
Y
SW
1
0
T
H
S
T
DWY DWY DWY DWY
TRAFFIC CONTROL PLAN
JOB # P.103130.C.45
PERMIT #
Legend
CONES
MANHOLE
WORK TRUCK
WORK AREA
SPOTTER
Arrowboard (Chevron)
ONE LANE TWO WAY TAPER 50' MIN/100' MAX
Date:3/20/23 Author:Darlene Durr, Traffic Control Supervisor Project:P.103130.C.45
CERT:TCS # 011915 LUMEN:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be DETERMINED BY CITY, COUNTY AND/OR WSDOT.
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #011915, darlene.durr@hotmail.com
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60
Approved 3/20/2023Darlene Durr
TCS # 011915
Phone 253-737-5198darlene.durr@hotmail.com
_______________________Darlene Durr
NOT TO SCALE
NOTE ALL LANE WIDTHS ARE ESTIMATES; FOR ACCURANCY, MEASURE IN FIELD PRIOR TO
WORK.
REFER TO CHARTS FOR DEVICE SPACING,
SIGNAGE SPACING, SIGN SIZE, BUFFER
SPACING AND TAPER LENGTHS.ROADWORKAHEADS
MH 111ROADWORKAHEAD ROADWORKAHEADNComments:
THIS IS TO ACCESS MH 111.
THIS IS A RIGHT LANE CLOSURE.SIDEWALK IS ACCESSIBLE.
SPOTTER WILL ASSIST AT WORK AREA.
DRIVEWAYS REMAIN ACCESSIBLE AT WORK AREA.
WORK AREA
10' X 300'
SPEEDLIMIT
30
LIND AVE SW @ SW 10TH ST
MH 111 ACCESS
RIGHT LANE CLOSURE
200'200'
200'
200'
200'
MERGING TAPER150'RIGHT LANECLOSEDAHEADwww.invarion.com
MFP23001830
DWY
DWY
LIND AVE SW
S
W
G
R
A
D
Y
W
A
Y
S
W
G
R
A
D
Y
W
A
Y
SW
1
0
T
H
S
T
SW
1
2
T
H
S
T
S
W
1
2
T
H
S
T
TRAFFIC CONTROL PLAN
JOB # P.103130.C.45
PERMIT #
Legend
CONES
MANHOLE
Arrowboard (Double)
WORK TRUCK
WORK AREA
SPOTTER ONE LANE TWO WAY TAPER 50' MIN/100' MAX
Date:3/20/23 Author:Darlene Durr, Traffic Control Supervisor Project:P.103130.C.45
CERT:TCS # 011915 LUMEN:Certified Traffic Control Plan (DO NOT ALTER)
Comments:
General Requirements
1. All signs and spacing to conform to the MUTCD and CITY OF RENTON
requirements.2. Channelizing devices are 28" traffic cones with retro reflective material.3. All signs are 48' X 48' B/O unless otherwise specified.
4. Alert affected local residents and businesses.
5. Crew is required to leave a minimum 11' for lane width.6. Work hours will be DETERMINED BY CITY, COUNTY AND/OR WSDOT.
UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO
ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN
IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM:
DARLENE DURR, TCS #011915, darlene.durr@hotmail.com
CHANNELIZING DEVICE SPACING (FEET)
MPH TAPER TANGENT
50/70
35/45
25/30
40
40
30
20
80
60
Approved 3/20/2023Darlene Durr
TCS # 011915
Phone 253-737-5198darlene.durr@hotmail.com
_______________________Darlene Durr
NOT TO SCALE
NOTE ALL LANE WIDTHS ARE ESTIMATES; FOR ACCURANCY, MEASURE IN FIELD PRIOR TO
WORK.
REFER TO CHARTS FOR DEVICE SPACING,
SIGNAGE SPACING, SIGN SIZE, BUFFER
SPACING AND TAPER LENGTHS.ROADWORKAHEADCENTERLANECLOSEDAHEADTHRUTRAFFICMERGELEFTRIGHT LANEMUSTTURN RIGHTS
MH 112
ROADWORKAHEADROADWORKAHEADROADWORKAHEAD ROADWORKAHEAD ROADWORKAHEADROADWORKAHEADWORK AREA
10' X 100'KEEPLEFTNComments:
THIS IS TO ACCESS MH 112.
THIS IS A CENTER LANE CLOSURE AND RIGHT LANE CLOSURE.
SIDEWALK IS ACCESSIBLE.SPOTTER WILL ASSIST AT WORK AREA.
DRIVEWAY REMAIN ACCESSIBLE AT WORK AREA.WORK AREA
10' X 285'
SPEEDLIMIT
30
LIND AVE SW @ SW 10TH ST
MH 112 ACCESS
CENTER LANE CLOSURE
RIGHT LANE CLOSURE
200'200'200'
350'
350'200'
200'
200'
200'
www.invarion.com
MFP23001830
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF BEFORE YOU DIG811CALL TWO WORKING DAYSRNGE:SECT:TOWN:GEO CODE:WC CLLI:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.4000000000”NVICINITY MAPSCOPE OF WORK:IN MANHOLE 110, PUSH LRE27, 187-188 FROM EXISTING FIBER CABLE [UA68] TO EXISTING FIBER STUB [A3J6Y].FROM STUB [A3J6Y] PUSH TO EXISTING FIBER CABLE [A2TSA]. IN MANHOLE 111, PUSH FIBER CABLE [A2TSA] TOEXISTING FIBER CABLE [A2TSE]. IN MANHOLE 112, SPLICE FIBER CABLE [A2TSE] TO NEW FIBER CABLE BEINGPLACED APPROX. 250' THROUGH EXISTING CONDUIT TO HANDHOLE UN-201. IN HANDHOLE UN-201, SPLICE TONEW FIBER CABLE BEING PLACED APPROX. 270' THROUGH EXISTING CONDUIT TO MPOP. PLACE NEWEQUIPMENT AND FDP IN MPOP. CUSTOMER TO PROVIDE BE. ENTRANCE SHOULD BE EXISTING.FIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMDRAFTED BY: MOUNTAIN LTD/DL - 02/27/2323N5E19P.103130W26226RNTNWA01955 LIND AVE SWRENTON, WA 9805715FIBER ENGINEER: LEANN MILLERPHONE NO: (720) 607-5687MFP23001830
TTEE CATV
CATV
CATV GG TS TS WW S S SD SD IRRIG IRRIG C/L C/L
R/W R/W R/W P/L P/L B/C B/C B
/C
EOP EOP TTTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'XITEM #STATIONPSEPROPOSED HOAPOLE NUMBER(S) - CTL/PWR/OTHERITEM#STAHT-CL-YRXX'-X"POLE#MAKE READYEXISTING ATTACHMENTSNOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTJOB:SH OF RNGE:SECT:TOWN:GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSFIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMDRAFTED BY: MOUNTAIN LTD/DL - 02/27/2323N5E19P.103130W26226RNTNWA01955 LIND AVE SWRENTON, WA 9805725FIBER ENGINEER: LEANN MILLERPHONE NO: (720) 607-5687MFP23001830
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSNOTE:IN MANHOLE 110, PUSH LRE27, 187-188 FROM EXISTINGFIBER CABLE [UA68] TO EXISTING FIBER STUB [A3J6Y].FROM STUB [A3J6Y] PUSH TO EXISTING FIBER CABLE[A2TSA]. EOP EOP EOP EOP R/W EOP EOP R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W 48'53'37'41'39'39'9' GRASS5' S/W48'37'42'T20'11'720#1923059060501#1923059056440#1823059252550#1823059251FIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMDRAFTED BY: MOUNTAIN LTD/DL - 02/27/2323N5E19P.103130W26226RNTNWA01955 LIND AVE SWRENTON, WA 9805735FIBER ENGINEER: LEANN MILLERPHONE NO: (720) 607-5687SPEEDLIMITSPEEDLIMITMFP23001830
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSNOTE:IN MANHOLE 111, PUSH FIBER CABLE[A2TSA] TO EXISTING FIBER CABLE [A2TSE].FIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMDRAFTED BY: MOUNTAIN LTD/DL - 02/27/2323N5E19P.103130W26226RNTNWA01955 LIND AVE SWRENTON, WA 9805745FIBER ENGINEER: LEANN MILLERPHONE NO: (720) 607-5687SPEEDLIMIT EOP EOP EOP EOP
EOP EOP EOP EOP
R/W R/W R/W R/W R/W R/W
R/W R/W R/W R/W R/W R/W 707#1923059056846#1923059064715#1923059061T48'11'65'10' DIRT
6' S/W 40'40'MFP23001830
NOTICE-NOT FOR DISCLOSURE OUTSIDE OF CENTURYLINK AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTRNGE:SECT:TOWN:JOB:SH OF GEO CODE:WC CLLI: BEFORE YOU DIG811CALL TWO WORKING DAYSNOTE:IN MANHOLE 112, SPLICE FIBER CABLE [A2TSE] TO NEW FIBER CABLE BEINGPLACED APPROX. 250' THROUGH EXISTING CONDUIT TO HANDHOLE UN-201. INHANDHOLE UN-201, SPLICE TO NEW FIBER CABLE BEING PLACED APPROX.270' THROUGH EXISTING CONDUIT TO MPOP. PLACE NEW EQUIPMENT ANDFDP IN MPOP. CUSTOMER TO PROVIDE BE. ENTRANCE SHOULD BE EXISTING.FIELD ENGINEER: RICK FERDINANDOPHONE NO: (206) 276-3165EMAIL: RICK.FERDINANDO@LUMEN.COMDRAFTED BY: MOUNTAIN LTD/DL - 02/27/2323N5E19P.103130W26226RNTNWA01955 LIND AVE SWRENTON, WA 9805755FIBER ENGINEER: LEANN MILLERPHONE NO: (720) 607-5687SPEEDLIMIT955#1923059062 EOP EOP EOP EOP EOP EOP
EOP EOP
R/W R/W R/W R/W
R/W R/W R/W R/W R/W
EOP EOP EOP EOP EOP
R/W R/W R/W R/W R/W R/W R/W R/W TT
48'40'40'10' DIRT6' S/W6' S/W6'80'4'10'900#1923059047858#192305906740'SPEEDLIMITNOTE:250' OF NEW 24F IN EX UG.NOTE:150' OF NEW24F IN EX UG.MFP23001830