Loading...
HomeMy WebLinkAboutMFP23001353.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP23001353 IVR Number: 23001353 Permit Information Permit Name: N.981417 Address/Location:03/14/2023Application Date:1432401000Parcel Number: 11635 SE 170TH PL Permit Type:05/03/2023Issue Date:Franchise Permit Work Class:05/02/2024Expiration Date:Major Utility Job Number: N.981417Franchise Type:Telephone Description: Lumen to access MH192, HH11640, perform approx. 10' of trenching, place new pad mounted FSAI, and overlashing aerial fiber across 87 poles. This will be a disturbance of surface with restoration. POTHOLE ALL EXISTING UTILITIES. RESTORATION PER CITY OF RENTON STANDARDS. Contacts Name Address PhoneTypeBilling Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549ApplicantX Austin Sweeney Century Link 23315 66th Ave S Kent, WA 98032 C: (253) 766-7549Contact Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Jesse Patjens CenturyLink / Lumen 23315 66th Ave S Kent, WA 98032 Contact Michael Smith North Sky Communications 21320 84th Ave S Kent, WA 98032 C: (206) 305-5881Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 23315 66th Ave S Kent, WA 98032 Specialized Billing General Conditions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. Ÿ This permit and plans must be posted at the job site at all times.Ÿ I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Ÿ Call 425.430.7203 or go to: https://permitting.rentonwa.gov one working day in advance to schedule an inspections and for ANY work in the Right of Way. Ÿ Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation.Ÿ In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 425.235.7736) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. Ÿ (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. DEPARTMENT OF PUBLIC WORKS Page 1 of 3 | Published: 10/27/2021 Transportation Division | 1055 South Grady Way, 5th Floor | Renton, WA 98057 | 425-430-7380 Website: rentonwa.gov TRAFFIC CONTROL PLAN APPLICATION Published: 10/27/2021 TRAFFIC CONTROL PLAN (TCP) MUST BE SUBMITTED TO PUBLIC WORKS TRANSPORTATION DIVISION FOR REVIEW/APPROVAL AT LEAST FIVE (5) WORKING DAYS BEFORE THE DATE OF WORK. The City of Renton requires any contractor, firm, corporation, or other public/private agency to prepare a traffic control plan (TCP) and obtain city's approval of that plan when construction, repair, or maintenance work is to be conducted within the city's right-of-way. 1. Fill out the Traffic Control Plan (TCP) Application form and prepare required submittal documents. 2. The following items are all required for submittal of the TCP Application: ☐Electronic Copy of the TCP Application ☐Electronic Copy of the TCP Layout, on 11” X 17” paper size format, which shall: Include map(s) showing the location of the project and work area. Be legible lettering and clear, contrasting, symbols of viewing or printing. Must indicate street names, and north arrow and scale. Types of plans required: o Work hour plan – show all mobility impacts during construction hours. o Non-work plan - show all mobility impacts after work hours when limited or no work is happening in the right-of-way (ROW), if applicable. o Changing construction phases – show construction sequence and each construction phase change even if the traffic control is not modified, if applicable. o Pedestrian access/detour plan, if applicable. - Shall conform to the Washington State Traffic Control Flagger Certification handbook, by the Evergreen Safety Council. 3. Submit Application via email to TCP@rentonwa.gov with the subject line “TCP Application – [Project Name].” Project Name: Permit #: Site Address: Work Date: From _____________ To _____________ Work Time: Start ______________ End ______________ Construction Company: Contact Name: Phone/Cell: _________________________ Business Address: City/State: Zip: Description of Work: Approval By: _________________________________________________ Date:____________________ Transportation Engineering Northsky Communications Tawnya Longfellow 22517 88th ave S Kent/WA 98031 N.981417 11635 SE 170th Pl Lumen to access MH192, HH11640, perform approx. 10' of trenching, place new pad mounted FSAI, and overlashing aerial fiber across 87 poles. This will be a disturbance of surface with restoration MFP23001352 Monday - Friday 8:00AM - 3:00PM Scott Warlick CED 5/3/2023 Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 2 of 3 | Published: 10/27/2021 PERMIT HOLDER AGREES TO ALL THE FOLLOWING: Must have approved Traffic Control Plan (TCP) prior to commencing the work. Maintain existing pedestrian access. The work on pedestrian facilities, shall be limited to one corner at a time, with the least possible inconvenience or delay to pedestrians. WORK TIME begins when any street or travel lane is fully or partially closed. This includes set up within the traveled way. Comply with all traffic regulations of the City of Renton and the State of Washington. Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. Contractor or entity must call Renton School District (425-204-4455) or any public/private agency, including public transit, to be affected by a temporary lane or road closure a minimum of five business days (excluding weekends and holidays) prior to starting any work. Contractor or entity must notify King County Metro in writing at construction.coord@kingcounty.gov a minimum of five business days (excluding weekends and holidays) prior to starting any work impacting bus stops, a temporary lane or road closure. Work requiring removing a bus shelter or sign requires notification in writing a minimum of 30 business days (excluding weekends and holidays). Please call King County Metro at 206-477-1140 with any questions. Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 Signs or Flaggers at thoroughfare work sites and R.C.W. 9A.36.050 Reckless Endangerment, and other applicable State and City codes. Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. All permit conditions shall be met. NOTES: Total road closure lasting more than twenty-four (24) hours is subject to the approval by the City Council. Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by a traffic control plan layout or reference to WSDOT. Approved Temporary Traffic Control Plan must be at the work site during work hours. Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded to safely redirect pedestrians around a work zone. Signage shall be used to warn motorcyclists/bicyclists of the potential hazards on any uneven surfaced or slippery road conditions during work and non-work hours. Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. Note: The Applicant is responsible for compliance with all codes and regulations, whether or not described in this document. Page 3 of 3 | Published: 10/27/2021 In the case of Temporary No Parking Zones, all the following apply in addition to previous: Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block seventy-two (72) hours in advance of effective date and time. The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). I certify that the information on this application and within the submittal documents are accurate to the best of my knowledge and I acknowledge all the requirements on this application. Applicant’s Signature Date Applicant’s Name (Print) Austin Sweeney Austin Sweeney 3/14/2023 Imagery and map data ©2023, Google 125 ft*125 ft*200 ft 200 ft 200 ft 100 ft 100 ft 100 ft 200 ft 200 ft 200 ft60 ft60 ft 60 ft 85 ft 100 ft 100 ft 100 ft ROADWORKAHEADROADWORKAHEADROADWORKAHEAD ROADWORKAHEADROADWORKAHEADROADWORKAHEADROADWORKAHEADONE LANEROADAHEADONE LANEROADAHEADONE LANEROADAHEADONE LANEROADAHEADSLOWSTOPSLOW STOPSLOWSTOPS L O W S TO P Plan Scale 1 : 1800 (1'' = 150') N Legend Cone 28 in Flagger Symbol ONE LANEROADAHEAD One Lane Road Ahead ROADWORKAHEAD Road Work Ahead SLOWSTOP Stop-Slow Flagger Work Area Manifest 23 x Cone 28 in 7 x Road Work Ahead 4 x Flagger Symbol 4 x One Lane Road Ahead 4 x Stop-Slow Flagger This stage to be used for aerial, trenching, and MH access in this intersection. AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:Traffic Control Consultants Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone::N/A Permit #:TBDWork Hours:$hours$TCC Job #:2023-0083 Est. Start Date:Will begin upon approval of TCP or per Contractor's directive. Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD and WSDOT SPECIFICATIONS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS STAGE 1www.invarion.com MFP23001352 Imagery and map data ©2023, Google 200 ft200 ft 75 ft 200 ft 200 ft 200 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft ROADWORKAHEADROADWORKAHEADROADWORKAHEADROADWORKAHEADROADWORKAHEADROADWORKAHEAD ROADWORKAHEADBE PREPAREDTO STOPBE PREPAREDTO STOPBE PREPAREDTO STOPSLOWSTOPSLOWSTOP SLOWSTOPONE LANEROADAHEADPlan Scale 1 : 1800 (1'' = 150') N Red distance marker with breakline indicates distance not to scale. Please place in sign stack at distance notated next to breakline. This is a moving work zone. All Road Work Ahead signs, as well as the Flagger Symbol and One Lane Road Ahead signs on SE 168th St to remain in place for duration of this stage. While work is happening at each intersection, traffic on side roads shall be controlled by additional flagger(s) and other signs depicted on side road(s) shall be deployed. Cones to be deployed around work vehicle(s) while stationary, and are not depicted on diagram. Ensure flagger taper length of 50-100 ft, and cones spaced not more than 20 feet apart.^^^^^^^^^^^^2- B 2- A Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 2 A Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 50 ft 200 ft 200 ft 200 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft ROADWORKAHEAD ROADWORKAHEAD ROADWORKAHEAD ROADWORKAHEAD ROADWORKAHEADROADWORKAHEAD ROADWORKAHEADROADWORKAHEADBE PREPAREDTO STOP BE PREPAREDTO STOP BE PREPARED TO STOP BE PREPARED TO STOPBE PREPAREDTO STOPSLOWSTOPSLOWSTOPSLOWSTOPSLOWSTOPSLOWSTOP SLOWSTOPONE LANEROADAHEADPlan Scale 1 : 1800 (1'' = 150') N Legend BE PREPAREDTO STOP Be Prepared To Stop Flagger Symbol ONE LANEROADAHEAD One Lane Road Ahead ROADWORKAHEAD Road Work Ahead SLOWSTOP Stop-Slow Flagger Work Area Manifest 15 x Road Work Ahead 9 x Flagger Symbol 9 x Stop-Slow Flagger 7 x Be Prepared To Stop 2 x One Lane Road Ahead ^^^^^^^^^^^^2- B 2- A Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 2 B Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 100 ft 200 ft 200 ft 100 ft100 ft 100 ft 100 ft 100 ft 200 ft 200 ft SLOWSTOPROADWORKAHEADROADWORKAHEADROADWORKAHEADROADWORKAHEADBE PREPAREDTO STOPBE PREPAREDTO STOPBE PREPAREDTO STOPSLOWSTOPBE PREPAREDTO STOPPlan Scale 1 : 1800 (1'' = 150') NLegend BE PREPAREDTO STOP Be Prepared To Stop Flagger Symbol ROADWORKAHEAD Road Work Ahead SLOWSTOP Stop-Slow Flagger Work Area Manifest 4 x Be Prepared To Stop 4 x Road Work Ahead 2 x Flagger Symbol 2 x Stop-Slow Flagger Cones to be deployed around work vehicle(s) while stationary, and are not depicted on diagram. Ensure flagger taper length of 50-100 ft, and cones spaced not more than 20 feet apart. AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:Traffic Control Consultants Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone::N/A Permit #:TBDWork Hours:$hours$TCC Job #:2023-0083 Est. Start Date:Will begin upon approval of TCP or per Contractor's directive. Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD and WSDOT SPECIFICATIONS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS STAGE 3www.invarion.com MFP23001352 Imagery and map data ©2023, Google 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ftROADWORKAHEAD ROADWORKAHEADROADWORKAHEADROADWORKAHEADONE LANEROADAHEADBE PREPAREDTO STOPBE PREPAREDTO STOPBE PREPAREDTO STOPSLOWSTOPSLOWSTOPSLOWSTOPSLOWSTOPPlan Scale 1 : 1800 (1'' = 150') N Legend BE PREPAREDTO STOP Be Prepared To Stop Flagger Symbol ONE LANEROADAHEAD One Lane Road Ahead ROADWORKAHEAD Road Work Ahead SLOWSTOP Stop-Slow Flagger Work Area Manifest 8 x Flagger Symbol 8 x Road Work Ahead 8 x Stop-Slow Flagger 6 x Be Prepared To Stop 2 x One Lane Road Ahead This is a moving work zone. All Road Work Ahead signs, as well as the Flagger Symbol and One Lane Road Ahead signs on SE 168th St to remain in place for duration of this stage. While work is happening at each intersection, traffic on side roads shall be controlled by additional flagger(s) and other signs depicted on side road(s) shall be deployed. Cones to be deployed around work vehicle(s) while stationary, and are not depicted on diagram. Ensure flagger taper length of 50-100 ft, and cones spaced not more than 20 feet apart.^^^^^^^^^^^^4 -B 4 -A Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 4 A Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ft 100 ftROADWORKAHEADROADWORKAHEAD ROADWORKAHEADROADWORKAHEAD ONE LANEROADAHEADBE PREPAREDTO STOPBE PREPAREDTO STOPBE PREPAREDTO STOPSLOWSTOPSLOWSTOPSLOWSTOP SLOWSTOPPlan Scale 1 : 1800 (1'' = 150') N^^^^^^^^^^^^4 -B 4 -A Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 4 B Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 100 ft 200 ft 200 ft 100 ft ROADWORKAHEADROADWORKAHEADROADWORKAHEADONE LANEROADAHEADSLOWSTOPMoving Work Zone. Cones to be deployed around work vehicle(s) while stationary, and are not depicted on diagram. Ensure leading taper length of 50-100 ft, and cones spaced not more than 20 feet apart. Plan Scale 1 : 1800 (1'' = 150') N Legend ONE LANEROADAHEAD One Lane Road Ahead ROADWORKAHEAD Road Work Ahead SLOWSTOP Stop-Slow Flagger Work Area Manifest 5 x Road Work Ahead 2 x One Lane Road Ahead 2 x Stop-Slow Flagger ^^^^^^^^^^^^5-B 5-ADate:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 5 A Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 100 ft 100 ft 100 ft ROADWORKAHEADROADWORKAHEADONE LANEROADAHEADSLOWSTOPPlan Scale 1 : 1800 (1'' = 150') N Plan Scale 1 : 1800 (1'' = 150') N ^^^^^^^^^^^^5-B 5-A Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 5 B Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 75 ft 100 ft 100 ft 100 ft 100 ft 100 ft 200 ft 200 ft ONE LANEROADAHEADROADWORKAHEADROADWORKAHEADROADWORKAHEADROADWORKAHEADROADWORK AHEADONE LANEROADAHEADONE LANEROADAHEADSLOWSTOPSLOWSTOPSign at south end of SE 169th Pl are at reduced spacing due to constraints of distance. Expand to 100 ft spacing when able. Plan Scale 1 : 1800 (1'' = 150') N Legend ONE LANEROADAHEAD One Lane Road Ahead ROADWORKAHEAD Road Work Ahead SLOWSTOP Stop-Slow Flagger Work Area Manifest 5 x Road Work Ahead 3 x One Lane Road Ahead 2 x Stop-Slow Flagger Moving Work Zone. Cones to be deployed around work vehicle(s) while stationary, and are not depicted on diagram. Ensure leading taper length of 50-100 ft, and cones spaced not more than 20 feet apart. AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:Traffic Control Consultants Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone::N/A Permit #:TBDWork Hours:$hours$TCC Job #:2023-0083 Est. Start Date:Will begin upon approval of TCP or per Contractor's directive. Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD and WSDOT SPECIFICATIONS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS STAGE 6www.invarion.com MFP23001352 Imagery and map data ©2023, Google 75 ft 200 ft 200 ft 100 ft ROADWORKAHEADROADWORKAHEADROADWORKAHEADONE LANEROADAHEADSLOWSTOPPlan Scale 1 : 1800 (1'' = 150') N Legend ONE LANEROADAHEAD One Lane Road Ahead ROADWORKAHEAD Road Work Ahead SLOWSTOP Stop-Slow Flagger Work Area Manifest 6 x Road Work Ahead 3 x One Lane Road Ahead 2 x Stop-Slow FlaggerMoving Work Zone. Cones to be deployed around work vehicle(s) while stationary, and are not depicted on diagram. Ensure leading taper length of 50-100 ft, and cones spaced not more than 20 feet apart.^^^^^^^^^^^^7-B 7-ADate:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 7 A Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 100 ft 100 ft 100 ft 100 ft 100 ftROADWORKAHEAD ROADWORKAHEADROADWORKAHEADONE LANEROADAHEADONE LANEROADAHEADSLOWSTOPPlan Scale 1 : 1800 (1'' = 150') N ^^^^^^^^^^^^7-B 7-A Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 7 B Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 100 ft 200 ft 200 ft ROADWORKAHEADROADWORKAHEADONE LANEROADAHEADSLOWSTOPLegend ONE LANEROADAHEAD One Lane Road Ahead ROADWORKAHEAD Road Work Ahead SLOWSTOP Stop-Slow Flagger Work Area Manifest 4 x Road Work Ahead 2 x One Lane Road Ahead 2 x Stop-Slow Flagger Plan Scale 1 : 1800 (1'' = 150') N Moving Work Zone. Cones to be deployed around work vehicle(s) while stationary, and are not depicted on diagram. Ensure leading taper length of 50-100 ft, and cones spaced not more than 20 feet apart.^^^^^^^^^^^^8-B 8-ADate:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 8 A Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 75 ft 100 ft 100 ft ROADWORKAHEADROADWORKAHEADONE LANEROADAHEADSLOWSTOP Plan Scale 1 : 1800 (1'' = 150') N Plan Scale 1 : 1800 (1'' = 150') N^^^^^^^^^^^^8-B 8-A Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 8 B Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 100 ft 200 ft 200 ft ROADWORKAHEADROADWORKAHEADONE LANEROADAHEADPlan Scale 1 : 1800 (1'' = 150') N Legend ONE LANEROADAHEAD One Lane Road Ahead ROADWORKAHEAD Road Work Ahead SLOWSTOP Stop-Slow Flagger Work Area Manifest 4 x Road Work Ahead 2 x One Lane Road Ahead 2 x Stop-Slow Flagger Moving Work Zone. Cones to be deployed around work vehicle(s) while stationary, and are not depicted on diagram. Ensure leading taper length of 50-100 ft, and cones spaced not more than 20 feet apart.SLOWSTOP^^^^^^^^^^^^9-B 9-ADate:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 9 A Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 75 ft 100 ft 100 ft ROADWORKAHEADROADWORKAHEADONE LANEROADAHEADSLOWSTOP Plan Scale 1 : 1800 (1'' = 150') N^^^^^^^^^^^^9-B 9-A Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 9 B Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 100 ft 200 ft 200 ft ROADWORKAHEADROADWORKAHEADONE LANEROADAHEADSLOWSTOPPlan Scale 1 : 1800 (1'' = 150') N Legend ONE LANEROADAHEAD One Lane Road Ahead ROADWORKAHEAD Road Work Ahead SLOWSTOP Stop-Slow Flagger Work Area Manifest 4 x Road Work Ahead 2 x One Lane Road Ahead 2 x Stop-Slow Flagger ^^^^^^^^^^^^10-B 10-A Moving Work Zone. Cones to be deployed around work vehicle(s) while stationary, and are not depicted on diagram. Ensure leading taper length of 50-100 ft, and cones spaced not more than 20 feet apart. Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 10 A Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 75 ft 100 ft 100 ft ROADWORKAHEADROADWORKAHEADONE LANEROADAHEADSLOWSTOP Plan Scale 1 : 1800 (1'' = 150') N ^^^^^^^^^^^^10-B 10-A Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 10 B Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 100 ft 200 ft 200 ft ROADWORKAHEADROADWORKAHEADONE LANEROADAHEADSLOWSTOPPlan Scale 1 : 1800 (1'' = 150') N Legend ONE LANEROADAHEAD One Lane Road Ahead ROADWORKAHEAD Road Work Ahead SLOWSTOP Stop-Slow Flagger Work Area Manifest 4 x Road Work Ahead 2 x One Lane Road Ahead 2 x Stop-Slow Flagger Moving Work Zone. Cones to be deployed around work vehicle(s) while stationary, and are not depicted on diagram. Ensure leading taper length of 50-100 ft, and cones spaced not more than 20 feet apart.^^^^^^^^^^^^11-B 11-ADate:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 11 A Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 Imagery and map data ©2023, Google 75 ft 100 ft 100 ft ROADWORKAHEADROADWORKAHEADONE LANEROADAHEADSLOWSTOP Plan Scale 1 : 1800 (1'' = 150') N Plan Scale 1 : 1800 (1'' = 150') N ^^^^^^^^^^^^11-B 11-A Date:3/30/2023 Author:Steven Newman Project:N.981417Traffic Control Company:TRAFFIC CONTROL CONSULTANTS Phone:541-548-3165 Address:PO Box 1827 Redmond, OR 97756Contractor Name:Mountain Ltd Contractor Phone:N/A Permit #:TBDTCC JOB#:2023-0083 Estimated Start Date:Will begin upon aproval of traffic control plan/ or per contractors directive Comments: -ALL TRAFFIC CONTROL MUST MEET MUTCD & WSDOT STANDARDS -TO DETERMINE SIGN SPACING USE " SIGN SPACING AND BUFFER TABLE" PROPRIETARY: THIS PLAN IS PROPERTY OF TRAFFIC CONTROL CONSULTANTS AERIAL/UNDERGROUND UTILITY CONSTRUCTION 168TH ST & 170TH PL -125TH AVE & 172ND ST RENTON WA STAGE 11 B Table 1. Advanced Warning Sign Spacing Freeways &Expressways Road Type Speed Distances Between Advance Warning Signs* A**B**C**D** 70 55 6560Rural Highways 5545Rural Roads Rural Roads andUrban Arerials 4035 Rural Roads, UrbanStreets, ResidentialBusiness Districts 30 25 Urban Streets 25orless 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 1,500.+/-orper theMUTCD. 800 ft.+/-800 ft.+/-800 ft.+/-800 ft.+/- 500 ft.+/-500 ft.+/-500 ft.+/-500 ft.+/- 300 ft.+/-300 ft.+/-300 ft.+/-300 ft.+/- 200 ft.+/-200 ft.+/-200 ft.+/-200 ft.+/- 100 ft.+/-100 ft.+/-100 ft.+/-100 ft.+/- www.invarion.com MFP23001352 WORK AREASCALE:01SH:OF CONSTRUCTION NOTES1. CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING.2. THE EXISTENCE AND LOCATION OF ANY UNDER GROUND UTILITY PIPES OR DIGGING. SECTION:TOWNSHIP:RANGE:GEO CODE:JOB:DATE:01/25/2022STRUCTURE SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTION AND A SEARCHOF THE AVAILABLE CITY OR COUNTY RECORDS.SINCE THE ACTUAL LOCATION AND NATURE OFTHE UNDER GROUND FACILITIES MAY BE SOME WHAT DIFFERENT FROM THE SHOWN. THECONTRACTOR IS REQUIRED TO VERIFY PRIOR TO EXCAVATION.FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY.PLACE WARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED,AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL WAY,STATE,AND LOCALREGULATIONS.3.ALL EXCAVATION ,TRENCHING, AND SHORING IS TO ADHERE TO THE CODE OF FEDERAL WAYREGULATIONS(CFR)1926.650 SUBPART P.4.a. PROVIDED ALL PITS WITH 1'X 1' SLOPE ART ONE END OF EXCAVATION FOR TECHNICIAN INGRESS/EGRESS.b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24" FROM EDGE OF PIT OR TRENCH.c. BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY. ALL BARRICADE MUST BE EQUIPPED WITH FLASHINGLIGHTS FOR NIGHT VISIBILITY.d. FOR PITS GREATER THAN 4' IN DEPTH ,USE APPROPRIATE SHORING FOR WALL STABILITYTRENCH COVER IS TO BE 9" MINIMUM AND FREE OF ROCKS,DEBRIS,AND CLODS.THE TRENCH ISTO BE A MINIMUM OF 9" COVER IN DEVELOPED AREAS AND A MINIMUM OF 48" OF COVER INUNDEVELOPED AREAS (ANY VARIANCE FROM THESE STANDARDS WILL BE SPECIFIED ON THEPLANS)5.6.ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGES AS A RESULTOF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER.7.NORMAL / GUIDED-BORING METHOD RECOMMENDED WHEN BORING.8.ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.9.BOND BURIED/AERIAL FACILITIES AS A REQUIRED BY JURISDICTIONAL AGENCY(S).10.AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINING WORK PER STATE AND LOCALREGULATIONS.11.12.ALL WORK AREA PROTECTION FOR TRAFFIC CONTROL IS TO BE WITH APPROVED WARNINGDEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKSENGINEERING.DEPARTMENT STANDARDS AND SPECIFICATIONS.IF REQUIRED A TRAFFICCONTROL PLAN SHALL BE SUBMITTED TO THE REQUESTING PERMITTING AGENCY PRIOR TOBEGINNING WORKPERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN ADVANCE OF CONSTRUCTIONACTIVITIES.EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINED AT ALL TIMES.AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BEPROVIDED AND MAINTAINED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLICWORKS ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS.13.THE FOLLOWING FOOTAGES ARE ESTIMATES.FOOTAGES TO BE VERIFIED PRIOR TOCONSTRUCTIONS.LCON NAME:LCON NUMBER:N/ASCOPE OF WORK:225E23N28N.9814171"=100'NAPOF:LUMEN TO SPLICE AT P1. AND RUN F1 CABLE AERIAL TO NEW FSAI LOCATION ON P1. AT 11635 SE 170TH PL. ALSO TO PLACE NEW AERIAL ON SURROUNDING STREETSAND SPLICE AT SEVERAL LOCATIONS.N/ACUSTOMER NAME:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.000124430000VICINITY MAPN/AARMOR ID:WFMT ID:N/AN/A BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:MARIA HAYES(253) 393-5387EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCCLLI:RNTNWA01REVISION:1NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMFP23001352This permit is for Major construction work in the ROW and will be billed at an additional$158/HR for inspections. After hours and weekend work will be billed at $175/HR TE CATV CATVG TSW S SD C/L R/W P/L B/C B/C EOPTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'X00POWER POLE #NTLUMEN POLE # / A #NT / NTPOLE HEIGHT-CLASS00-0PROP HOA0'-0"ATTACHMENTSHOAPOSITIONMISCMAKE READY NOTES:F1TTSCALE:02SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSSECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/20225E23N28FIBER ENGINEERNAME:PHONE:MARIA HAYES(253) 393-5387EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCCLLI:RNTNWA01REVISION:1NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMFP23001352 1180211658116681182311815116451165311659SE 168TH ST216B216B216B216B216B216B216B48F48F48F48F48F48F48F60'30'30' 19'19' 6 0 ' 3 0 ' 3 0 ' 1 5 ' 1 5 'P2P3P42P41P40P1MS=17'8"MS=18'2"MS=18'4"147'144'MS=19'1"MS=18'3"MS=17'9"177'71'133'179'MS=18'9"188'SE 170TH PLSE 168TH ST216A216A216A216A216A216ANEW FIBER CABLE 48 CT@ 1553'NEW FIBER CABLE216B CT@ 1996'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'1"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'5"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDTMH-192THH-11640SEE SHEET 04SEE SHEET 07PULL 57' NEW 24F FIBER CABLE INEXISITNG CONDUIT FROM MH-192 TOHH-11640PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"LUMEN SPLICELOCATIONFSAI 16723 SE 168TH ST LRE 25,545-552NEW FIBER CABLE24 CT@ 10'SCALE:03SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS. CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 16804168121680516811119191680311908119161681916820119111190116804SE 168TH ST120TH AV SE SE 168TH ST216B216B216B216B216B216B216B216B216BMSTMST48F48F48F48F48F50'25'25'16'16'60'30'30' 19'19'P56P52P51P43P44P45P53MS=18'5"MS=17'6"MS=15'8"MS=15'4"122'143'149'144'MS=17'6"MS=18'1"MS=17'9"219'194'148'SE 169TH PL50'25'25'17'17'NEW FIBER CABLE 48 CT@ 1553'NEW FIBER CABLE216B CT@ 1996'NEW FIBER CABLE12 CT@ 132'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'9"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'7"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 21'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'1"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'5"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATED04SEE SHEET 03 SEE SHEET 05SEE SHEET 08SCALE:04SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS. CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 1681116812168191682016803168271680316828168191681116803168111682716820168281680416812168271681916804SE 168TH STSE 168TH ST122ND AVE SE 123RD AVE SE 216B216B216B216B216B216B216B216B216B48A 48C48C48C48C48C 48D 48D 48D 48D 48D 50'25'25'17'17'50'25'25'17'17'50'25'25'17'17'P77P76P67P57P60P58P68P69P39P59MS=17'6"MS=17'6"MS=17'0"MS=17'0"MS=16'4"144' 145' 146' 207' 137'MS=20'9"MS=17'0"MS=19'1"MS=18'8"169'204'163'100'MS=15'5"36'60' 30'30' 19'19' 121ST AVE SE NEW FIBER CABLE216B CT@ 1996'NEW FIBER CABLE 48D CT@ 1090'NEW FIBER CABLE 48C CT@ 1237'NEW FIBER CABLE216B CT@ 1996'NEW FIBER CABLE 48A CT@ 1164'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'1"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 04 SEE SHEET 06SEE SHEET 09SCALE:05SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MS="210'MFP23001352 16820168271682716811168041680316819168281681116820168121681916812168041682816803SE 168TH STSE 168TH ST125TH AVE SE 124TH AV SE 216B216B216B48B48B48B48B48B 60'30'30'19'19'60'30'30' 19'19' 60'30'30'19'19'50'25'25'17'17'P30P31P79P78P80MS=13'6"MS=17'8"MS=17'5"145'74'MS=17'9"209'145'MS=19'3"MS=17'3"116'145'SE 168TH ST216A216A NEW FIBER CABLE 48B CT@ 1242'NEW FIBER CABLE216B CT@ 1996'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 23'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 13'3"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 05 SEE SHEET 10SCALE:06SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01P80P81167'80'129'MFP23001352 116651181011823118181183911809118011183111817SE 170TH PL6 0 ' 3 0 ' 3 0 ' 1 5 ' 1 5 'P4P5MS=18'6"MS=18'9"141'150'216A216A216A216A216A216ANEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'0"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 03S E E SH E E T 0 8SCALE:07SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 1200111852120181182611939120121192511838168341193112004119091191711832118461682812007119341192416827SE 169TH PL48F48F48F48F48F48F48F60'30'30'15'15'50'25'25'16'16'5 0 ' 2 5 ' 2 5 ' 1 7 ' 1 7 ' 5 0 ' 2 5 ' 2 5 ' 1 7 ' 1 7 'P6P46P47P48P54P55MS=18'7"MS=17'8"MS=17'3"MS=17'3"MS=18'6"143'146'144'148'174'SE 169TH PL120 T H A V S E216A216A216ANEW FIBER CABLE 48 CT@ 1553'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'7"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 17'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'4"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 11SEE SHEET 04SEE SHEET 07 SEE SHEET 11SCALE:08SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 168631684216858168351685116848168471683616856168421685516836168631684116848120381686416847168411686416841168351683516855123RD AVE SE 121ST AVE SE 48A 48A 48A 48A 48A 48C48C48C48C48C 48D 48D 48D 48D 48D 48D 50'25'25'17'17'50'25'25'17'17'50'25'25'17'17'P62P61P69P70P71P36P37P38MS=17'8"MS=17'8"MS=16'8"MS=17'0"MS=17'5"MS=17'8"MS=19'9"158' 143' 140' 161' 171'142'144' 122ND AVE SE NEW FIBER CABLE 48D CT@ 1090'NEW FIBER CABLE 48C CT@ 1237'NEW FIBER CABLE 48A CT@ 1164'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'7"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 05SEE SHEET 12SCALE:09SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 1683616847168471685616863168361685516835168641684116842168351686316856168481684216848168551684116864124TH AV SE 125TH AVE SE 48B48B48B48B48B 60'30'30'19'19'50'25'25'17'17'P27P28P29P81P82P83MS=18'4"MS=17'9"MS=17'1"MS=18'2"158' 140' 140'158' 216A216A216A216A216ANEW FIBER CABLE 48B CT@ 1242'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'9"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'7"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 06SEE SHEET 13SCALE:10SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 119101200011860118511186811902118451695912015118671202816967118731200812023169511187411905120291185912037SE 170TH PLSE 170TH PL48F48F48F6 0 ' 3 0 ' 3 0 ' 1 5 ' 1 5 'P7P8P9P10P49P50MS=17'8"MS=18'4"MS=19'5"MS=17'4"MS=18'0"143'117'150'112'118'SE 169TH PL216A216A216A216A216A216A216A216ANEW FIBER CABLE 48 CT@ 1553'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'7"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'7"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 14SEE SHEET 08SEE SHEET 08SCALE:11SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 17017170111701217025170031700416974170261703317034170331701716958169821700317011169501702517018121ST AVE SE 122ND AVE SE 123RD AVE SE1696648A48A48A48A48A 48A 48C48C48C48C48C 48D 48D 48D 48D 48D50'25'25'17'17'50'25'25'17'17'50'25'25'17'17'P63P64P65P72P73P34P35MS=14'4"MS=13'0"MS=19'3"MS=18'0"MS=16'5"MS=17'8"MS=18'2"MS=18'7"MS=18'3"140'145'158' 159' 143'143' 136'144'75'NEW FIBER CABLE 48D CT@ 1090'NEW FIBER CABLE 48C CT@ 1237'NEW FIBER CABLE 48A CT@ 1164'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'7"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 17'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 09SEE SHEET 15SCALE:12SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 17004170121701117034170031701217026170331701717011171031700417017170251702617018170031702517018124TH AVE SE 125TH AVE SE 48B48B48B48B48B 60'30'30'19'19'50'25'25'17'17'P25P26P84P85MS=17'9"MS=18'4"MS=16'7"MS=18'2"MS=17'2"MS=16'9"146'141'156' 162'142'142' 216A216A216A216A216ANEW FIBER CABLE 48B CT@ 1242'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'7"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 10SEE SHEET 1617034SCALE:13SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 120181200517101120311201512105SE 170TH PL6 0 ' 3 0 ' 3 0 ' 1 5 ' 1 5 'P11P12P13MS=18'3"MS=18'6"MS=18'0"MS=12'8"92'140'67'130'216A216A216A216A216ANEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 17'3"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 11S E E SH E E T 1 5SCALE:14SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 12108122071212112204170401705312145170391704612306170461704512116121291220112301122151704512113170391221012137SE 172ND ST123RD AVE SE 122ND AVE SE SE 172ND ST48A 48A 48A 48A 48A 48C48C 60'30'30' 15'15'50'25'25'17'17'50'25'25'17'17'50'25'25'17'17'P14P17P18P66P74P75P32P33P15P16MS=16'0"MS=17'0"MS=17'0"MS=18'8"MS=19'4"MS=16'0"MS=18'5"MS=16'7"116'154'143144'144'143' 138' 144'216A216A216A216A216A216A216A216A216A216ANEW FIBER CABLE 48D CT@ 1090'NEW FIBER CABLE 48C CT@ 1237'NEW FIBER CABLE216A CT@ 4012'NEW FIBER CABLE 48A CT@ 1164'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'1"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 17'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 17'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'1"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'2"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 16 SEE SHEET 12SEE SHEET 14 SCALE:15SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 17121123231704512407123071704617039124151240112314170541704017040171151231517109SE 172ND ST124TH AV SE 48B48B 60'30'30' 15'15'50'25'25'17'17'60'30'30'19'19'P19P20P21P22P23P24P86P87MS=19'4"MS=19'4"MS=17'3"MS=16'9"MS=16'0"MS=17'4"88'128'145' 144'140'144'SE 172ND ST125TH AVE SE 216A216A216A216A216A216A216A216A216A216A216ANEW FIBER CABLE 48B CT@ 1242'NEW FIBER CABLE216A CT@ 4012'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'1"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'9"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'4"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 15 SEE SHEET 13SCALE:16SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 2POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-5"STREET LIGHT 20'-2"004 COMCAST005 LUMEN/CTL18'-5"1POWER POLE #NALUMEN POLE # / A #POLE OWNERPSEPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-4"STREET LIGHT 22'-0"FIBER004 COMCAST005 LUMEN/CTL20'-5"NANAPSENANASECONDARY27'-2"SECONDARYFIBERNA24'-1"3POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL25'-8"STREET LIGHT 20 '-2"004 COMCAST005 LUMEN/CTL19'-3"PSENANASECONDARYFIBERNA25'-0"4POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-6"STREET LIGHT 22'-4"004 COMCAST005 LUMEN/CTL19'-0"PSENANASECONDARYFIBERNANA5POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-6"PSENANASECONDARYFIBERNANANA6POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-7"PSENANASECONDARYFIBERNANA22'-4"7POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-4"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-7"PSENANASECONDARYFIBERNANANA8POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-4"PSENANASECONDARYFIBERNA24'-0"22'-5"9POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL24'-4"PSENANASECONDARYFIBERNA18'-4"NA10POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL28'-9"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-2"PSENANASECONDARYFIBERNA28'-9"NA11POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL23'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL17'-3"PSENANASECONDARYFIBERNANA23'-6"12POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-2"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-8"PSENANASECONDARYFIBERNANA25'-2"13POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL28'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-2"PSENANASECONDARYFIBERNA27'-5"23'-1"14POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL23'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL17'-6"PSENASECONDARYFIBERNA23'-8"/20'-7"/19'-4"/18'-2"316662-166723NA15POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-0"STREET LIGHT004 COMCAST005 LUMEN/CTL17'-4"/17'PSENASECONDARYFIBERNA25'-0"/17'-0"316653-16673321'-2"EXISTING PWR, CATV & LUMEN DG&A'S, OHG'S WEST.OVERLASH EXISTING STRAND/CABLE WITH F2 FOC TO P2.OVERLASH EXISTING STRAND/CABLE TO P40.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P3.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P4. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P5. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P6. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P7. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P8. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P9. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P10. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P11. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P12. LITTLE TREE TRIM INSPAN.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P13. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S WEST SOUTH.OVERLASH EXISTING STRAND/CABLE WITH F2 FOC TO P14.EXISTING PWR, CATV & LUMEN DG&A'S SOUTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P15. BOND TOGRND.EXISTING PWR, CATV & LUMEN DG&A'S WEST. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P16.30' - 221'8"40' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 419'3"20'20'2"20'7"20'5"20'6"20'2"19'6"21'5"18'9"21'2"20'7"18'2"19'7"SCALE:17SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 16POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-5"PSENASECONDARYFIBERNA24'-6"/18'-5"316653-16674922'-3"17POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-3"PSENASECONDARYFIBERNA24'-0"/19'-4"NANA18POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-0"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNANANA21'-9"19'-1"19POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-0"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA316651-16676824'-1"NA20POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA316651-25'-2"23'-0"20'-3"23POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-5"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA25'-2"22'-2"19'-0"NA24POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-6"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA25'-3"22'-4"19'-5"NA25POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA24'-4"23'-5"19'-3"316692-16682626POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-9"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA25'-5"23'-6"20'-7"NA27POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL28'-8"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA25'-1"23'-2"20'-2"316722-16682728POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL26'-3"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA24'-7"24'-0"20'-7"316738-15682729POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-7"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA24'-9"23'-5"20'-5"30POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-7"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA23'-8"20'-1"13'-3"316738-15682719'-4"21POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL29'-2"STREET LIGHT004 COMCAST005 LUMEN/CTLNASECONDARYFIBERNA28'-9"22'-3"19'-1"NANA22POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-0"STREET LIGHT004 COMCAST005 LUMEN/CTLNASECONDARYFIBERNA25'-2"NANANAEXISTING PWR, CATV & LUMEN DG&A'S SOUTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P17.EXISTING PWR, CATV CABLE,OVERLASH NEWSTRAND/CABLE WITH F2 FOC TO P18. BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S SOUTH. OVERLASHNEW STRAND/CABLE WITH F2 FOC TO P19. BOND TO GRND.EXISTING PWR, CATV CABLE. OVERLASH NEWSTRAND/CABLE WITH F2 FOC TO P20.EXISTING PWR, CATV CABLE. OVERLASH NEWSTRAND/CABLE WITH F2 FOC TO P21.EXISTING PWR, CATV CABLE, DG&A'S EAST. OVERLASHNEW STRAND/CABLE WITH F2 FOC TO P22. BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S SOUTH&WEST.OVERLASH NEW STRAND/CABLE WITH F2 FOC TO P23.EXISTING PWR, CATV &LUMEN DG&A'S SOUTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P24. BOND TOGRND.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P25. BOND TO GRND.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P26.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P27. BOND TO GRND.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P28. BOND TO GRND.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P29.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P30.LITTLE TREE TRIM INSPAN, SPAN TO P30. BOND TO GRND.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P32.HEAVY TREE TRIM INSPAN TO P32. BOND TO GRND.18'-9"40' - 440' - 440' - 440' - 440' - 440' - 422'40' - 420'40' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 420'2"19'4"20'3"21'21'1"20'1"20'8"20'1"21'8"22'4"22'5"21'9"22'NASCALE:18SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS. CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 32POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-8"31POWER POLE #NALUMEN POLE # / A #POLE OWNERPSEPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-7"STREET LIGHT20'-1"FIBER004 COMCAST005 LUMEN/CTL13'-3"NANAPSE316665-166774NASECONDARY23'-8"SECONDARYFIBERNA25'-1"33POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL29'-6"STREET LIGHT25'-8"004 COMCAST005 LUMEN/CTL18'-2"PSENASECONDARYFIBERNA29'-3"34POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-0"PSENASECONDARYFIBERNA35POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL26'STREET LIGHT004 COMCAST005 LUMEN/CTL18'-7"PSENASECONDARYFIBERNA25'-6"20'-9"36POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL26'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-5"PSE316723-166776NASECONDARYFIBERNA25'-3"37POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL27'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-7"PSE316739- 166776NASECONDARYFIBERNA25'-6"21'-4"38POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-2"PSENANASECONDARYFIBERNA24'-0"39POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL26'-7"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-0"PSE316788-166777NASECONDARYFIBERNA25'-0"20'-7"40POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-5"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-0"PSENANASECONDARYFIBERNA25'-2"23'-5"41POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL23'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-8"PSENANASECONDARYFIBERNA22'-1"23'-6"/21'-1"42POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL23'-2"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-1"CTLNANASECONDARYFIBERNANA23'-2"/16'-6"43POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-2"PSENANASECONDARYFIBERNA24'-6"21'-0"44POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL29'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-2"PSENASECONDARYFIBERNA316776-16639NA45POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-5"PSENASECONDARYFIBERNA22'-2"NA316679-166774316693-16677524'-6"NA316703-166775NANANANANAEXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC .HEAVY TREE TRIM IN SPAN.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P33. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P34. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P35.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P36.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P37. LITTLE TREE TRIM INSPAN TO P37. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P38. BOND TO GRND.BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P39.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P41.BOND TO GRND WITHRISER.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P42.LITTLE TREE TRIM INSPAN TO P42. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P43.EXISTING PWR, CATV CABLE, DG&A'S NORTH. OVERLASHNEW STRAND/CABLE WITH F2 FOC TO P44. BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S WEST. OVERLASHNEW STRAND/CABLE WITH F2 FOC TO P45.LITTLE TREETRIM IN SPAN TO P45. BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S WEST. OVERLASHNEW STRAND/CABLE WITH F2 FOC TO P46. BOND TO GRND.40' - 4NA40' - 445' - 240' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 445' - 540' - 440' - 340' - 321'1"18'7"21'3"19'7"21'7"19'8"21'6"19'7"21'3"21'1"20'7"20'2"21'21'1"SCALE:19SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS. CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 47POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL29'-7"STREET LIGHT22'-4"004 COMCAST005 LUMEN/CTL18'-6"46POWER POLE #NALUMEN POLE # / A #POLE OWNERPSEPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-4"STREET LIGHTFIBER004 COMCAST005 LUMEN/CTL18'-5"NANAPSE316742-166686NASECONDARYSECONDARYFIBERNA29'-3"48POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL26'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-4"PSENANANASECONDARYFIBERNA24'-4"49POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL26'-5"STREET LIGHT23'-4"004 COMCAST005 LUMEN/CTL18'-3"PSENANASECONDARYFIBERNA50POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-9"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENANASECONDARYFIBERNANA51POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-5"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-9"PSENANASECONDARYFIBERNA24'-5"/20'-9"/19'-6"22'-6"52POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL26'-2"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-7"PSENANASECONDARYFIBERNA53POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-4"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-1"PSENANASECONDARYFIBERNA25'-4"54POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL17'-4"PSENANASECONDARYFIBERNA24'-8"55POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL26'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-5"PSE316750-166698NASECONDARYFIBERNA26'-1"/20'-5"NA56POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL29'-0"STREET LIGHT004 COMCAST005 LUMEN/CTL21'-4"PSE316798-166712NASECONDARYFIBERNA29'-0"/22'-8"/21'-4"57POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL28'-9"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-3"/22'-0"PSENANASECONDARYFIBERNA28'-9"58POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL23'-2"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-4"PSE316775-366730NASECONDARYFIBERNA23'-2"/21'-0"59POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRALSTREET LIGHT004 COMCAST005 LUMEN/CTL18'-1"CTLNASECONDARYFIBERNA18'-1"/17'4"16'6"681ANANANA20'-8"18'-7"18'-7"23'-3"26'-2"NA20'-7"27'-6"24'-7"NA60POWER POLE #316761-166729LUMEN POLE # / A #POLE OWNERPSEPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOA POSITION MISCNEUTRAL22'-8"STREET LIGHTFIBER004 COMCAST005 LUMEN/CTL18'-3"NANASECONDARY22'-8"21'-1"EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P47.BOND TO GRND.LITTLE TREE TRIM IN SPAN TO P47. BOND TO GRND.EXISTING PWR, CATV & LUMEN, DG&A'S WEST. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P48. BOND TOGRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P49.LITTLE TREE TRIM TOSPAN. BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S WEST&SOUTH.OVERLASH NEW STRAND/CABLE WITH F2 FOC TO P50.BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S WEST.OVERLASH NEW STRAND/CABLE WITH F2 FOC. BONDTO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P52. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S, WEST. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P53.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P54. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S, SOUTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P55. BOND TOGRND.EXISTING PWR, CATV CABLE WITH F2 FOC TO P56.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P57. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S, OHG'S NORTH.OVERLASH EXISTING STRAND/CABLE WITH F2 FOC TO P58.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P59. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P61. BOND TO GRND.NA40' - 240' - 440' - 440' - 320'6"20'8"21'2"21'8"40' - 420'5"40' - 422'7"20'4"40' - 420'3"40' - 421'1"45' - 422'8"40' - 421'4"40' - 321'0"40' - 419'2"40' - 420'9"40'-430'-5SCALE:20SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 61POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'STREET LIGHT004 COMCAST005 LUMEN/CTL19'-7"PSE316747-1666729NASECONDARYFIBERNA24'-0\21-'0"62POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-1"STREET LIGHT 21'-6"004 COMCAST005 LUMEN/CTL19'-3"PSENANASECONDARYFIBERNA24'-1"\20'-5"63POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL29'-5"STREET LIGHT 27'-5"004 COMCAST005 LUMEN/CTL20'-5"PSE316723-166728NASECONDARYFIBERNA29'-5"64POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'STREET LIGHT004 COMCAST005 LUMEN/CTL18'-8"PSE316768-166725NASECONDARYFIBERNA25'\19'-8"\18'-8"20'6"65POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL17'-3"PSE316594-166727NASECONDARYFIBERNA25'-3\20'20'-7"66POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'STREET LIGHT004 COMCAST005 LUMEN/CTL19'-1"PSENANASECONDARYFIBERNA24'\19'-1"21'-7"67POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-9"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-5"\22'-2"PSENANASECONDARYFIBERNA24'-9"\21'-6"\20'-5"23'-2"68POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-5"STREET LIGHT004 COMCAST005 LUMEN/CTL19'PSE316768-166751NASECONDARYFIBERNA25'-5"\20'-3"\19'21'-3"69POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-5"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-2"PSE316754-166751NASECONDARYFIBERNA25'-5"\19'-5"\18'2"NA70POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'STREET LIGHT004 COMCAST005 LUMEN/CTL18'-3"PSE316739-166750NASECONDARYFIBERNA21'25'\19'\18'-3"71POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-4"PSE316724-166750NASECONDARYFIBERNANA24'\20'-6"\19'-4"72POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-6"PSE316703-166749NASECONDARYFIBERNA25'-3"\20'-7"\19'-6"23'-7"73POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL22'-4"STREET LIGHT004 COMCAST005 LUMEN/CTL18'PSENASECONDARYFIBERNA22'-4"\19'-5"316694-166749NA74POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL23'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL19'PSENASECONDARYFIBERNA23'-8"\20'-6"\19'316680-16674621'-6"75POWER POLE #LUMEN POLE # / A #POLE OWNERPSEPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL23'-4"STREET LIGHT NAFIBER004 COMCAST005 LUMEN/CTL18'-2"NANASECONDARY23'\20'\18'-2"NAEXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P63.EXISTING PWR, CATV & LUMEN DG&A'S EAST. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P64.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P65. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S EAST. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P66. BOND TOGRND.EXISTING PWR, CATV , DG&A'S EAST .CABLE WITH F2 FOCTO P67.EXISTING PWR, CATV & LUMEN, OHG'S NORTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P68. BOND TOGRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P69. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P70. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P71. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P72. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P72,LITTLE TREE TRIM INSPAN TO P73. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P74. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S SOUTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P75. BOND TOGRND.EXISTING PWR, CATV .CABLE WITH F2 FOC TO P76.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P62. BOND TO GRND.40' - 421'0"40' - 520'5"45' - 323'1"40' - 319'8"40' - 320'40' - 519'7"40' - 421'6"40' - 520'3"40' - 519'5"40' - 519'40' - 420'6"40' - 420'7"40' - 419'5"40' - 420'6"40' - 420'NASCALE:21SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 76POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL22'-4"STREET LIGHT NA004 COMCAST005 LUMEN/CTL17'-3"\19'-2"PSENANASECONDARYFIBERNA22'-4"\18'-3"\17'-3"77POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL26'-3"STREET LIGHT 26'-0"004 COMCAST005 LUMEN/CTL21'-0"\23'-0"PSENANASECONDARYFIBERNA26'-3"78POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-1"STREET LIGHT NA004 COMCAST005 LUMEN/CTL18'-3"\20'-6"PSE316768-166789NASECONDARYFIBERNA24'-1"\18'-3"79POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL30'-2"STREET LIGHT004 COMCAST005 LUMEN/CTL23'-3"\20'-6"PSENANASECONDARYFIBERNA30'-2"\22'-3"25'-4"80POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL25'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-2"PSE316767-166803NASECONDARYFIBERNA25'-3"23'-2"81POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'STREET LIGHT004 COMCAST005 LUMEN/CTL19'-9"PSE316752-168802NASECONDARYFIBERNA24'-8"NA82POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-6"PSE316734-166807NASECONDARYFIBERNA25'21'-1"83POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL25'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-8"PSE316723-166801NASECONDARYFIBERNA25'-1"NA84POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-4"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-2"PSE316707-166801NASECONDARYFIBERNA25'-3"22'-6"85POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'STREET LIGHT004 COMCAST005 LUMEN/CTL18'-5"PSE316692-166800NASECONDARYFIBERNANA24'-4"86POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-3"PSE316679-166800NASECONDARYFIBERNA21'-5"24'-9"87POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-6"PSE316664-166800NASECONDARYFIBERNA25'NAEXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P77. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P78,HEAVY TREE TRIM INSPAN.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P79, LITTLE TREE TREETRIM IN SPAN TO P79. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S NORTH.OVERLASH EXISTING STRAND/CABLE WITH F2 FOC TO P80.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P81. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P82.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P83.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P83,LITTLE TREE TRIM INSPAN TO P84. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P85.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P86. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P87. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S NORTH.OVERLASH EXISTING STRAND/CABLE WITH F2 FOC.40' - 418'3"45' - 322'0"40' - 419'8"40' - 422'3"40' - 421'6"20'6"40' - 419'6"40' - 421'4"40' - 420'7"40' - 419'5"40' - 419'8"40' - 419'6"40' - 4SCALE:22SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 City of Renton, Public Works Department This letter is requesting an Aerial Variance regarding a Lumen permit request to place fiber on job N.981417. This job will provide fiber service to approximately 235 Lumen customers/potential customers located in the immediate area of SE 168TH ST It will also prepare for any future growth in this area. These existing customers are currently being fed by copper cable and the most efficient and cost- effective way to provide the customer fiber Internet service is to distribute the fiber aerially. We will be accessing an existing HH and MH. Then placing an FSAI and then over lashing to 87 poles. Please let us know if you have specific questions in regards to our build. Thank You, Nathan Macleod SR NIPM Engineer Phone:253-583-6283 Nathan.macleod@lumen.com May 3, 2023 Nathan Macleod Lumen Via Email: Nathan.macleod@lumen.com SUBJECT: Request for Undergrounding Exemption (N.981417, MFP23001353, 11635 SE 170th Pl) Dear Mr. Macleod: The City of Renton has reviewed your request to grant CenturyLink an exemption from Renton Municipal Code (RMC) 4-6-090(C) which states that all new electrical or communication facilities shall be required to be installed underground, pursuant to the standards of the section of RMC. CenturyLink proposes to have North Sky Communications overlash approximately 12,443 lineal feet of new aerial fiber to existing Puget Sound Energy (PSE) power poles along SE 168th St, SE 169th Pl, SE 170th Pl, SE 172nd St, 120th Ave SE, 121st Ave SE, 122nd Ave SE, 123rd Ave SE, 124th Ave SE, and 125th Ave SE within the City. See the enclosed Site Plan showing the proposed overlashing limits. ANALYSIS: The City has considered the request for an exemption from RMC 4-6-090. City of Renton Municipal Code 5-19-2.B.1 and 2 states that “Except as otherwise provided herein, any telecommunications carriers who desire to construct, install, operate, maintain, or otherwise locate telecommunications facilities in, under, over or across any public way of the City, and to also provide telecommunications service to persons or areas in the City, shall first obtain a franchise granting the use of such public ways from the City pursuant to Section 5-19-3 of this Chapter.” CenturyLink does not have a franchise agreement with the City, as its predecessor-in-interest held a blanket grant of authority, dating back to territorial times, and therefore has unique status as compared to other telecommunications purveyors. Per Eric J. Schwalb, Senior Corporate Counsel for CenturyLink, RCW Section 35.99.030 states that a city or town may not require a “master permit” from service providers seeking access to public rights-of-way who have an existing statewide grant, as Century Link has. Furthermore, the Washington State Constitution, Article XII, Section 19, grants the right to construct and maintain lines of telegraph and telephone within this state. While we concur that VOIP is allowed per the RCW and Washington State Constitution, cable service is not a right granted without a franchise. Therefore, this analysis will focus on the overhead fiber proposed to be installed for Data/VOIP, and not the provision of future cable. In addition, staff considered RMC 4-6-090.D. which allows for exemptions due to technological difficulties; when costs outweigh the general welfare consideration implicit in underground installation; or, if the growth pattern of the area has not been sufficiently established to determine the ultimate service routes. Century Link Job N.981417 Page 2 of 2 May 3, 2023 In this instance, the portion of the route proposed for aerial installation is in an area where cost to underground one utility service will be cost prohibitive. DECISION: The requested exemption from underground utility installation requirements RMC4-6-090 (C) as requested by the applicant for the Project Reach is approved with conditions subject to the conditions below as the request complies with exemption criteria of RMC 4-6-090(D)(1)(i)(ii). Conditions of Approval: 1. Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15’-6”. 2. Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. 3. A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 4. The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at Century Link’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case Century Link shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City, from the first event triggering the requirement to underground the aerial lines. This decision to approve the exemption with conditions is subject to a fourteen (14) day appeal period from the date of this letter per RMC 4-8-110. Any appeals of the administrative decision must be filed with the City Clerk, along with the required appeal fee, by 5:00 pm, May 17, 2023. Due to the ongoing state of emergency enacted by Governor’s Proclamation 20-05, the City Clerk’s Office is working remotely. For that reason, appeals must be submitted electronically to the City Clerk at cityclerk@rentonwa.gov or delivered to City Hall 1st floor Lobby Hub only on Tuesdays and/or Wednesdays. The appeal fee, normally due at the time an appeal is submitted, will be collected at a future date if your appeal is submitted electronically. Appeals to the Hearing Examiner are governed by RMC 4-8-110 and additional information regarding the appeal process may be obtained from the City Clerk’s Office, cityclerk@rentonwa.gov. Sincerely, Brianne Bannwarth, PE Development Engineering Director cc: C.E. “Chip” Vincent, CED Administrator Nathan Janders, Development Engineering Manager Justin Johnson, Construction Engineering Manager Scott Warlick, Engineering Specialist III Holly Powers, Engineering Specialist III Austin Sweeney, CenturyLink Austin.Sweeney@centurylink.com Franchise Permits WORK AREASCALE:01SH:OF CONSTRUCTION NOTES1. CALL UTILITY LOCATE AT 811 72 HOURS PRIOR TO TRENCHING OR DIGGING.2. THE EXISTENCE AND LOCATION OF ANY UNDER GROUND UTILITY PIPES OR DIGGING. SECTION:TOWNSHIP:RANGE:GEO CODE:JOB:DATE:01/25/2022STRUCTURE SHOWN ON THESE PLANS WERE OBTAINED BY FIELD INSPECTION AND A SEARCHOF THE AVAILABLE CITY OR COUNTY RECORDS.SINCE THE ACTUAL LOCATION AND NATURE OFTHE UNDER GROUND FACILITIES MAY BE SOME WHAT DIFFERENT FROM THE SHOWN. THECONTRACTOR IS REQUIRED TO VERIFY PRIOR TO EXCAVATION.FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY.PLACE WARNING DEVICES AND WORK AREA PROTECTION ASREQUIRED,AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL WAY,STATE,AND LOCALREGULATIONS.3.ALL EXCAVATION ,TRENCHING, AND SHORING IS TO ADHERE TO THE CODE OF FEDERAL WAYREGULATIONS(CFR)1926.650 SUBPART P.4.a. PROVIDED ALL PITS WITH 1'X 1' SLOPE ART ONE END OF EXCAVATION FOR TECHNICIAN INGRESS/EGRESS.b. EXCAVATED SPOILS ARE TO BE NO LESS THAN 24" FROM EDGE OF PIT OR TRENCH.c. BARRICADE ALL OPEN PITS AND TRENCHING FOR PUBLIC SAFETY. ALL BARRICADE MUST BE EQUIPPED WITH FLASHINGLIGHTS FOR NIGHT VISIBILITY.d. FOR PITS GREATER THAN 4' IN DEPTH ,USE APPROPRIATE SHORING FOR WALL STABILITYTRENCH COVER IS TO BE 9" MINIMUM AND FREE OF ROCKS,DEBRIS,AND CLODS.THE TRENCH ISTO BE A MINIMUM OF 9" COVER IN DEVELOPED AREAS AND A MINIMUM OF 48" OF COVER INUNDEVELOPED AREAS (ANY VARIANCE FROM THESE STANDARDS WILL BE SPECIFIED ON THEPLANS)5.6.ALL ASPHALT/CONCRETE AND LANDSCAPING REMOVED, DISTURBED, OR DAMAGES AS A RESULTOF CONSTRUCTION SHALL BE RESTORED TO ORIGINAL CONDITION OR BETTER.7.NORMAL / GUIDED-BORING METHOD RECOMMENDED WHEN BORING.8.ADHERE TO AIRTIGHT GUIDELINES UNLESS OTHERWISE NOTED.9.BOND BURIED/AERIAL FACILITIES AS A REQUIRED BY JURISDICTIONAL AGENCY(S).10.AERIAL FACILITIES ARE TO BE TESTED PRIOR TO BEGINING WORK PER STATE AND LOCALREGULATIONS.11.12.ALL WORK AREA PROTECTION FOR TRAFFIC CONTROL IS TO BE WITH APPROVED WARNINGDEVICES AND PLACED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLIC WORKSENGINEERING.DEPARTMENT STANDARDS AND SPECIFICATIONS.IF REQUIRED A TRAFFICCONTROL PLAN SHALL BE SUBMITTED TO THE REQUESTING PERMITTING AGENCY PRIOR TOBEGINNING WORKPERMITTING AGENCIES MUST BE NOTIFIED 48 HOURS IN ADVANCE OF CONSTRUCTIONACTIVITIES.EXISTING PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BE MAINTAINED AT ALL TIMES.AS NECESSARY, TEMPORARY PEDESTRIAN CROSSWALKS AND WALKING AREAS SHALL BEPROVIDED AND MAINTAINED PER STATE DEPARTMENT OF TRANSPORTATION AND/OR PUBLICWORKS ENGINEERING DEPARTMENT STANDARDS AND SPECIFICATIONS.13.THE FOLLOWING FOOTAGES ARE ESTIMATES.FOOTAGES TO BE VERIFIED PRIOR TOCONSTRUCTIONS.LCON NAME:LCON NUMBER:N/ASCOPE OF WORK:225E23N28N.9814171"=100'NAPOF:LUMEN TO SPLICE AT P1. AND RUN F1 CABLE AERIAL TO NEW FSAI LOCATION ON P1. AT 11635 SE 170TH PL. ALSO TO PLACE NEW AERIAL ON SURROUNDING STREETSAND SPLICE AT SEVERAL LOCATIONS.N/ACUSTOMER NAME:TOTAL EXISTING CONDUIT USED:TOTAL NEW BORE:TOTAL NEW DIRT TRENCHESTIMATED TOTALSTOTAL NEW AERIAL:SIDEWALK (PCC) R&R:ASPHALT (AC) R&R:S.F.S.F.L.F.L.F.L.F.L.F.TOTAL NEW ASPHALT TRENCH:L.F.TOTAL NEW S/W TRENCH:L.F.000124430000VICINITY MAPN/AARMOR ID:WFMT ID:N/AN/A BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:MARIA HAYES(253) 393-5387EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCCLLI:RNTNWA01REVISION:1NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMFP23001352 TE CATV CATVG TSW S SD C/L R/W P/L B/C B/C EOPTUSAMEEPWREETVTVVTSVWSSDVETTTXXX'XXX'XXX'XXX'X00POWER POLE #NTLUMEN POLE # / A #NT / NTPOLE HEIGHT-CLASS00-0PROP HOA0'-0"ATTACHMENTSHOAPOSITIONMISCMAKE READY NOTES:F1TTSCALE:02SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSSECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/20225E23N28FIBER ENGINEERNAME:PHONE:MARIA HAYES(253) 393-5387EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCCLLI:RNTNWA01REVISION:1NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMFP23001352 1180211658116681182311815116451165311659SE 168TH ST216B216B216B216B216B216B216B48F48F48F48F48F48F48F60'30'30' 19'19' 6 0 ' 3 0 ' 3 0 ' 1 5 ' 1 5 'P2P3P42P41P40P1MS=17'8"MS=18'2"MS=18'4"147'144'MS=19'1"MS=18'3"MS=17'9"177'71'133'179'MS=18'9"188'SE 170TH PLSE 168TH ST216A216A216A216A216A216ANEW FIBER CABLE 48 CT@ 1553'NEW FIBER CABLE216B CT@ 1996'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'1"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'5"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDTMH-192THH-11640SEE SHEET 04SEE SHEET 07PULL 57' NEW 24F FIBER CABLE INEXISITNG CONDUIT FROM MH-192 TOHH-11640PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"LUMEN SPLICELOCATIONFSAI 16723 SE 168TH ST LRE 25,545-552NEW FIBER CABLE24 CT@ 10'SCALE:03SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS. CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 16804168121680516811119191680311908119161681916820119111190116804SE 168TH ST120TH AV SE SE 168TH ST216B216B216B216B216B216B216B216B216BMSTMST48F48F48F48F48F50'25'25'16'16'60'30'30' 19'19'P56P52P51P43P44P45P53MS=18'5"MS=17'6"MS=15'8"MS=15'4"122'143'149'144'MS=17'6"MS=18'1"MS=17'9"219'194'148'SE 169TH PL50'25'25'17'17'NEW FIBER CABLE 48 CT@ 1553'NEW FIBER CABLE216B CT@ 1996'NEW FIBER CABLE12 CT@ 132'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'9"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'7"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 21'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'1"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'5"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATED04SEE SHEET 03 SEE SHEET 05SEE SHEET 08SCALE:04SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS. CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 1681116812168191682016803168271680316828168191681116803168111682716820168281680416812168271681916804SE 168TH STSE 168TH ST122ND AVE SE 123RD AVE SE 216B216B216B216B216B216B216B216B216B48A 48C48C48C48C48C 48D 48D 48D 48D 48D 50'25'25'17'17'50'25'25'17'17'50'25'25'17'17'P77P76P67P57P60P58P68P69P39P59MS=17'6"MS=17'6"MS=17'0"MS=17'0"MS=16'4"144' 145' 146' 207' 137'MS=20'9"MS=17'0"MS=19'1"MS=18'8"169'204'163'100'MS=15'5"36'60' 30'30' 19'19' 121ST AVE SE NEW FIBER CABLE216B CT@ 1996'NEW FIBER CABLE 48D CT@ 1090'NEW FIBER CABLE 48C CT@ 1237'NEW FIBER CABLE216B CT@ 1996'NEW FIBER CABLE 48A CT@ 1164'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'1"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 04 SEE SHEET 06SEE SHEET 09SCALE:05SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MS="210'MFP23001352 16820168271682716811168041680316819168281681116820168121681916812168041682816803SE 168TH STSE 168TH ST125TH AVE SE 124TH AV SE 216B216B216B48B48B48B48B48B 60'30'30'19'19'60'30'30' 19'19' 60'30'30'19'19'50'25'25'17'17'P30P31P79P78P80MS=13'6"MS=17'8"MS=17'5"145'74'MS=17'9"209'145'MS=19'3"MS=17'3"116'145'SE 168TH ST216A216A NEW FIBER CABLE 48B CT@ 1242'NEW FIBER CABLE216B CT@ 1996'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 23'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 13'3"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 05 SEE SHEET 10SCALE:06SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01P80P81167'80'129'MFP23001352 116651181011823118181183911809118011183111817SE 170TH PL6 0 ' 3 0 ' 3 0 ' 1 5 ' 1 5 'P4P5MS=18'6"MS=18'9"141'150'216A216A216A216A216A216ANEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'0"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 03S E E SH E E T 0 8SCALE:07SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 1200111852120181182611939120121192511838168341193112004119091191711832118461682812007119341192416827SE 169TH PL48F48F48F48F48F48F48F60'30'30'15'15'50'25'25'16'16'5 0 ' 2 5 ' 2 5 ' 1 7 ' 1 7 ' 5 0 ' 2 5 ' 2 5 ' 1 7 ' 1 7 'P6P46P47P48P54P55MS=18'7"MS=17'8"MS=17'3"MS=17'3"MS=18'6"143'146'144'148'174'SE 169TH PL120 T H A V S E216A216A216ANEW FIBER CABLE 48 CT@ 1553'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'7"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 17'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'4"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 11SEE SHEET 04SEE SHEET 07 SEE SHEET 11SCALE:08SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 168631684216858168351685116848168471683616856168421685516836168631684116848120381686416847168411686416841168351683516855123RD AVE SE 121ST AVE SE 48A 48A 48A 48A 48A 48C48C48C48C48C 48D 48D 48D 48D 48D 48D 50'25'25'17'17'50'25'25'17'17'50'25'25'17'17'P62P61P69P70P71P36P37P38MS=17'8"MS=17'8"MS=16'8"MS=17'0"MS=17'5"MS=17'8"MS=19'9"158' 143' 140' 161' 171'142'144' 122ND AVE SE NEW FIBER CABLE 48D CT@ 1090'NEW FIBER CABLE 48C CT@ 1237'NEW FIBER CABLE 48A CT@ 1164'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'7"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 05SEE SHEET 12SCALE:09SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 1683616847168471685616863168361685516835168641684116842168351686316856168481684216848168551684116864124TH AV SE 125TH AVE SE 48B48B48B48B48B 60'30'30'19'19'50'25'25'17'17'P27P28P29P81P82P83MS=18'4"MS=17'9"MS=17'1"MS=18'2"158' 140' 140'158' 216A216A216A216A216ANEW FIBER CABLE 48B CT@ 1242'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'9"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'7"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 06SEE SHEET 13SCALE:10SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 119101200011860118511186811902118451695912015118671202816967118731200812023169511187411905120291185912037SE 170TH PLSE 170TH PL48F48F48F6 0 ' 3 0 ' 3 0 ' 1 5 ' 1 5 'P7P8P9P10P49P50MS=17'8"MS=18'4"MS=19'5"MS=17'4"MS=18'0"143'117'150'112'118'SE 169TH PL216A216A216A216A216A216A216A216ANEW FIBER CABLE 48 CT@ 1553'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'4"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'7"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'7"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 14SEE SHEET 08SEE SHEET 08SCALE:11SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 17017170111701217025170031700416974170261703317034170331701716958169821700317011169501702517018121ST AVE SE 122ND AVE SE 123RD AVE SE1696648A48A48A48A48A 48A 48C48C48C48C48C 48D 48D 48D 48D 48D50'25'25'17'17'50'25'25'17'17'50'25'25'17'17'P63P64P65P72P73P34P35MS=14'4"MS=13'0"MS=19'3"MS=18'0"MS=16'5"MS=17'8"MS=18'2"MS=18'7"MS=18'3"140'145'158' 159' 143'143' 136'144'75'NEW FIBER CABLE 48D CT@ 1090'NEW FIBER CABLE 48C CT@ 1237'NEW FIBER CABLE 48A CT@ 1164'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'7"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 17'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'5"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 09SEE SHEET 15SCALE:12SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 17004170121701117034170031701217026170331701717011171031700417017170251702617018170031702517018124TH AVE SE 125TH AVE SE 48B48B48B48B48B 60'30'30'19'19'50'25'25'17'17'P25P26P84P85MS=17'9"MS=18'4"MS=16'7"MS=18'2"MS=17'2"MS=16'9"146'141'156' 162'142'142' 216A216A216A216A216ANEW FIBER CABLE 48B CT@ 1242'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'7"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 10SEE SHEET 1617034SCALE:13SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 120181200517101120311201512105SE 170TH PL6 0 ' 3 0 ' 3 0 ' 1 5 ' 1 5 'P11P12P13MS=18'3"MS=18'6"MS=18'0"MS=12'8"92'140'67'130'216A216A216A216A216ANEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 17'3"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 11S E E SH E E T 1 5SCALE:14SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 12108122071212112204170401705312145170391704612306170461704512116121291220112301122151704512113170391221012137SE 172ND ST123RD AVE SE 122ND AVE SE SE 172ND ST48A 48A 48A 48A 48A 48C48C 60'30'30' 15'15'50'25'25'17'17'50'25'25'17'17'50'25'25'17'17'P14P17P18P66P74P75P32P33P15P16MS=16'0"MS=17'0"MS=17'0"MS=18'8"MS=19'4"MS=16'0"MS=18'5"MS=16'7"116'154'143144'144'143' 138' 144'216A216A216A216A216A216A216A216A216A216ANEW FIBER CABLE 48D CT@ 1090'NEW FIBER CABLE 48C CT@ 1237'NEW FIBER CABLE216A CT@ 4012'NEW FIBER CABLE 48A CT@ 1164'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'1"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 17'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 17'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'1"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'8"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'2"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'2"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 16 SEE SHEET 12SEE SHEET 14 SCALE:15SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 17121123231704512407123071704617039124151240112314170541704017040171151231517109SE 172ND ST124TH AV SE 48B48B 60'30'30' 15'15'50'25'25'17'17'60'30'30'19'19'P19P20P21P22P23P24P86P87MS=19'4"MS=19'4"MS=17'3"MS=16'9"MS=16'0"MS=17'4"88'128'145' 144'140'144'SE 172ND ST125TH AVE SE 216A216A216A216A216A216A216A216A216A216A216ANEW FIBER CABLE 48B CT@ 1242'NEW FIBER CABLE216A CT@ 4012'NEW FIBER CABLE216A CT@ 4012'PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'6"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'0"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'5"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'1"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 18'9"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 20'3"PLACE NEW FIBER CABLE ONEXISTING STRAND @ 19'4"SEE SHEETS 17-22 FORPOLE INFORMATIONALL AERIALOVERLASHED UNLESSOTHERWISE INDICATEDSEE SHEET 15 SEE SHEET 13SCALE:16SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 2POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-5"STREET LIGHT 20'-2"004 COMCAST005 LUMEN/CTL18'-5"1POWER POLE #NALUMEN POLE # / A #POLE OWNERPSEPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-4"STREET LIGHT 22'-0"FIBER004 COMCAST005 LUMEN/CTL20'-5"NANAPSENANASECONDARY27'-2"SECONDARYFIBERNA24'-1"3POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL25'-8"STREET LIGHT 20 '-2"004 COMCAST005 LUMEN/CTL19'-3"PSENANASECONDARYFIBERNA25'-0"4POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-6"STREET LIGHT 22'-4"004 COMCAST005 LUMEN/CTL19'-0"PSENANASECONDARYFIBERNANA5POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-6"PSENANASECONDARYFIBERNANANA6POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-7"PSENANASECONDARYFIBERNANA22'-4"7POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-4"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-7"PSENANASECONDARYFIBERNANANA8POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-4"PSENANASECONDARYFIBERNA24'-0"22'-5"9POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL24'-4"PSENANASECONDARYFIBERNA18'-4"NA10POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL28'-9"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-2"PSENANASECONDARYFIBERNA28'-9"NA11POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL23'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL17'-3"PSENANASECONDARYFIBERNANA23'-6"12POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-2"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-8"PSENANASECONDARYFIBERNANA25'-2"13POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL28'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-2"PSENANASECONDARYFIBERNA27'-5"23'-1"14POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL23'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL17'-6"PSENASECONDARYFIBERNA23'-8"/20'-7"/19'-4"/18'-2"316662-166723NA15POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-0"STREET LIGHT004 COMCAST005 LUMEN/CTL17'-4"/17'PSENASECONDARYFIBERNA25'-0"/17'-0"316653-16673321'-2"EXISTING PWR, CATV & LUMEN DG&A'S, OHG'S WEST.OVERLASH EXISTING STRAND/CABLE WITH F2 FOC TO P2.OVERLASH EXISTING STRAND/CABLE TO P40.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P3.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P4. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P5. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P6. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P7. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P8. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P9. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P10. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P11. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P12. LITTLE TREE TRIM INSPAN.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P13. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S WEST SOUTH.OVERLASH EXISTING STRAND/CABLE WITH F2 FOC TO P14.EXISTING PWR, CATV & LUMEN DG&A'S SOUTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P15. BOND TOGRND.EXISTING PWR, CATV & LUMEN DG&A'S WEST. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P16.30' - 221'8"40' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 419'3"20'20'2"20'7"20'5"20'6"20'2"19'6"21'5"18'9"21'2"20'7"18'2"19'7"SCALE:17SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 16POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-5"PSENASECONDARYFIBERNA24'-6"/18'-5"316653-16674922'-3"17POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-3"PSENASECONDARYFIBERNA24'-0"/19'-4"NANA18POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-0"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNANANA21'-9"19'-1"19POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-0"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA316651-16676824'-1"NA20POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA316651-25'-2"23'-0"20'-3"23POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-5"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA25'-2"22'-2"19'-0"NA24POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-6"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA25'-3"22'-4"19'-5"NA25POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA24'-4"23'-5"19'-3"316692-16682626POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-9"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA25'-5"23'-6"20'-7"NA27POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL28'-8"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA25'-1"23'-2"20'-2"316722-16682728POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL26'-3"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA24'-7"24'-0"20'-7"316738-15682729POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-7"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA24'-9"23'-5"20'-5"30POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-7"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENASECONDARYFIBERNA23'-8"20'-1"13'-3"316738-15682719'-4"21POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL29'-2"STREET LIGHT004 COMCAST005 LUMEN/CTLNASECONDARYFIBERNA28'-9"22'-3"19'-1"NANA22POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-0"STREET LIGHT004 COMCAST005 LUMEN/CTLNASECONDARYFIBERNA25'-2"NANANAEXISTING PWR, CATV & LUMEN DG&A'S SOUTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P17.EXISTING PWR, CATV CABLE,OVERLASH NEWSTRAND/CABLE WITH F2 FOC TO P18. BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S SOUTH. OVERLASHNEW STRAND/CABLE WITH F2 FOC TO P19. BOND TO GRND.EXISTING PWR, CATV CABLE. OVERLASH NEWSTRAND/CABLE WITH F2 FOC TO P20.EXISTING PWR, CATV CABLE. OVERLASH NEWSTRAND/CABLE WITH F2 FOC TO P21.EXISTING PWR, CATV CABLE, DG&A'S EAST. OVERLASHNEW STRAND/CABLE WITH F2 FOC TO P22. BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S SOUTH&WEST.OVERLASH NEW STRAND/CABLE WITH F2 FOC TO P23.EXISTING PWR, CATV &LUMEN DG&A'S SOUTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P24. BOND TOGRND.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P25. BOND TO GRND.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P26.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P27. BOND TO GRND.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P28. BOND TO GRND.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P29.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P30.LITTLE TREE TRIM INSPAN, SPAN TO P30. BOND TO GRND.EXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P32.HEAVY TREE TRIM INSPAN TO P32. BOND TO GRND.18'-9"40' - 440' - 440' - 440' - 440' - 440' - 422'40' - 420'40' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 420'2"19'4"20'3"21'21'1"20'1"20'8"20'1"21'8"22'4"22'5"21'9"22'NASCALE:18SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS. CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 32POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-8"31POWER POLE #NALUMEN POLE # / A #POLE OWNERPSEPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-7"STREET LIGHT20'-1"FIBER004 COMCAST005 LUMEN/CTL13'-3"NANAPSE316665-166774NASECONDARY23'-8"SECONDARYFIBERNA25'-1"33POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL29'-6"STREET LIGHT25'-8"004 COMCAST005 LUMEN/CTL18'-2"PSENASECONDARYFIBERNA29'-3"34POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-0"PSENASECONDARYFIBERNA35POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL26'STREET LIGHT004 COMCAST005 LUMEN/CTL18'-7"PSENASECONDARYFIBERNA25'-6"20'-9"36POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL26'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-5"PSE316723-166776NASECONDARYFIBERNA25'-3"37POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL27'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-7"PSE316739- 166776NASECONDARYFIBERNA25'-6"21'-4"38POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-2"PSENANASECONDARYFIBERNA24'-0"39POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL26'-7"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-0"PSE316788-166777NASECONDARYFIBERNA25'-0"20'-7"40POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-5"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-0"PSENANASECONDARYFIBERNA25'-2"23'-5"41POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL23'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-8"PSENANASECONDARYFIBERNA22'-1"23'-6"/21'-1"42POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL23'-2"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-1"CTLNANASECONDARYFIBERNANA23'-2"/16'-6"43POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL24'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-2"PSENANASECONDARYFIBERNA24'-6"21'-0"44POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL29'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-2"PSENASECONDARYFIBERNA316776-16639NA45POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-5"PSENASECONDARYFIBERNA22'-2"NA316679-166774316693-16677524'-6"NA316703-166775NANANANANAEXISTING PWR, CATV &LUMEN . OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC .HEAVY TREE TRIM IN SPAN.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P33. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P34. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P35.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P36.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P37. LITTLE TREE TRIM INSPAN TO P37. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P38. BOND TO GRND.BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P39.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P41.BOND TO GRND WITHRISER.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P42.LITTLE TREE TRIM INSPAN TO P42. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P43.EXISTING PWR, CATV CABLE, DG&A'S NORTH. OVERLASHNEW STRAND/CABLE WITH F2 FOC TO P44. BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S WEST. OVERLASHNEW STRAND/CABLE WITH F2 FOC TO P45.LITTLE TREETRIM IN SPAN TO P45. BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S WEST. OVERLASHNEW STRAND/CABLE WITH F2 FOC TO P46. BOND TO GRND.40' - 4NA40' - 445' - 240' - 440' - 440' - 440' - 440' - 440' - 440' - 440' - 445' - 540' - 440' - 340' - 321'1"18'7"21'3"19'7"21'7"19'8"21'6"19'7"21'3"21'1"20'7"20'2"21'21'1"SCALE:19SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED. RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS. CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TO ENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYE AND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 47POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL29'-7"STREET LIGHT22'-4"004 COMCAST005 LUMEN/CTL18'-6"46POWER POLE #NALUMEN POLE # / A #POLE OWNERPSEPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-4"STREET LIGHTFIBER004 COMCAST005 LUMEN/CTL18'-5"NANAPSE316742-166686NASECONDARYSECONDARYFIBERNA29'-3"48POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL26'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-4"PSENANANASECONDARYFIBERNA24'-4"49POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL26'-5"STREET LIGHT23'-4"004 COMCAST005 LUMEN/CTL18'-3"PSENANASECONDARYFIBERNA50POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-9"STREET LIGHT004 COMCAST005 LUMEN/CTLPSENANASECONDARYFIBERNANA51POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-5"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-9"PSENANASECONDARYFIBERNA24'-5"/20'-9"/19'-6"22'-6"52POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL26'-2"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-7"PSENANASECONDARYFIBERNA53POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-4"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-1"PSENANASECONDARYFIBERNA25'-4"54POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL17'-4"PSENANASECONDARYFIBERNA24'-8"55POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL26'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-5"PSE316750-166698NASECONDARYFIBERNA26'-1"/20'-5"NA56POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL29'-0"STREET LIGHT004 COMCAST005 LUMEN/CTL21'-4"PSE316798-166712NASECONDARYFIBERNA29'-0"/22'-8"/21'-4"57POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL28'-9"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-3"/22'-0"PSENANASECONDARYFIBERNA28'-9"58POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL23'-2"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-4"PSE316775-366730NASECONDARYFIBERNA23'-2"/21'-0"59POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRALSTREET LIGHT004 COMCAST005 LUMEN/CTL18'-1"CTLNASECONDARYFIBERNA18'-1"/17'4"16'6"681ANANANA20'-8"18'-7"18'-7"23'-3"26'-2"NA20'-7"27'-6"24'-7"NA60POWER POLE #316761-166729LUMEN POLE # / A #POLE OWNERPSEPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOA POSITION MISCNEUTRAL22'-8"STREET LIGHTFIBER004 COMCAST005 LUMEN/CTL18'-3"NANASECONDARY22'-8"21'-1"EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P47.BOND TO GRND.LITTLE TREE TRIM IN SPAN TO P47. BOND TO GRND.EXISTING PWR, CATV & LUMEN, DG&A'S WEST. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P48. BOND TOGRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P49.LITTLE TREE TRIM TOSPAN. BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S WEST&SOUTH.OVERLASH NEW STRAND/CABLE WITH F2 FOC TO P50.BOND TO GRND.EXISTING PWR, CATV CABLE, DG&A'S WEST.OVERLASH NEW STRAND/CABLE WITH F2 FOC. BONDTO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P52. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S, WEST. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P53.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P54. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S, SOUTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P55. BOND TOGRND.EXISTING PWR, CATV CABLE WITH F2 FOC TO P56.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P57. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S, OHG'S NORTH.OVERLASH EXISTING STRAND/CABLE WITH F2 FOC TO P58.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P59. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P61. BOND TO GRND.NA40' - 240' - 440' - 440' - 320'6"20'8"21'2"21'8"40' - 420'5"40' - 422'7"20'4"40' - 420'3"40' - 421'1"45' - 422'8"40' - 421'4"40' - 321'0"40' - 419'2"40' - 420'9"40'-430'-5SCALE:20SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 61POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'STREET LIGHT004 COMCAST005 LUMEN/CTL19'-7"PSE316747-1666729NASECONDARYFIBERNA24'-0\21-'0"62POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-1"STREET LIGHT 21'-6"004 COMCAST005 LUMEN/CTL19'-3"PSENANASECONDARYFIBERNA24'-1"\20'-5"63POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL29'-5"STREET LIGHT 27'-5"004 COMCAST005 LUMEN/CTL20'-5"PSE316723-166728NASECONDARYFIBERNA29'-5"64POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'STREET LIGHT004 COMCAST005 LUMEN/CTL18'-8"PSE316768-166725NASECONDARYFIBERNA25'\19'-8"\18'-8"20'6"65POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL17'-3"PSE316594-166727NASECONDARYFIBERNA25'-3\20'20'-7"66POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'STREET LIGHT004 COMCAST005 LUMEN/CTL19'-1"PSENANASECONDARYFIBERNA24'\19'-1"21'-7"67POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-9"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-5"\22'-2"PSENANASECONDARYFIBERNA24'-9"\21'-6"\20'-5"23'-2"68POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-5"STREET LIGHT004 COMCAST005 LUMEN/CTL19'PSE316768-166751NASECONDARYFIBERNA25'-5"\20'-3"\19'21'-3"69POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-5"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-2"PSE316754-166751NASECONDARYFIBERNA25'-5"\19'-5"\18'2"NA70POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'STREET LIGHT004 COMCAST005 LUMEN/CTL18'-3"PSE316739-166750NASECONDARYFIBERNA21'25'\19'\18'-3"71POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-4"PSE316724-166750NASECONDARYFIBERNANA24'\20'-6"\19'-4"72POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-6"PSE316703-166749NASECONDARYFIBERNA25'-3"\20'-7"\19'-6"23'-7"73POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL22'-4"STREET LIGHT004 COMCAST005 LUMEN/CTL18'PSENASECONDARYFIBERNA22'-4"\19'-5"316694-166749NA74POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL23'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL19'PSENASECONDARYFIBERNA23'-8"\20'-6"\19'316680-16674621'-6"75POWER POLE #LUMEN POLE # / A #POLE OWNERPSEPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL23'-4"STREET LIGHT NAFIBER004 COMCAST005 LUMEN/CTL18'-2"NANASECONDARY23'\20'\18'-2"NAEXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P63.EXISTING PWR, CATV & LUMEN DG&A'S EAST. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P64.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P65. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S EAST. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P66. BOND TOGRND.EXISTING PWR, CATV , DG&A'S EAST .CABLE WITH F2 FOCTO P67.EXISTING PWR, CATV & LUMEN, OHG'S NORTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P68. BOND TOGRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P69. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P70. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P71. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P72. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P72,LITTLE TREE TRIM INSPAN TO P73. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P74. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S SOUTH. OVERLASHEXISTING STRAND/CABLE WITH F2 FOC TO P75. BOND TOGRND.EXISTING PWR, CATV .CABLE WITH F2 FOC TO P76.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P62. BOND TO GRND.40' - 421'0"40' - 520'5"45' - 323'1"40' - 319'8"40' - 320'40' - 519'7"40' - 421'6"40' - 520'3"40' - 519'5"40' - 519'40' - 420'6"40' - 420'7"40' - 419'5"40' - 420'6"40' - 420'NASCALE:21SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 76POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL22'-4"STREET LIGHT NA004 COMCAST005 LUMEN/CTL17'-3"\19'-2"PSENANASECONDARYFIBERNA22'-4"\18'-3"\17'-3"77POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL26'-3"STREET LIGHT 26'-0"004 COMCAST005 LUMEN/CTL21'-0"\23'-0"PSENANASECONDARYFIBERNA26'-3"78POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-1"STREET LIGHT NA004 COMCAST005 LUMEN/CTL18'-3"\20'-6"PSE316768-166789NASECONDARYFIBERNA24'-1"\18'-3"79POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL30'-2"STREET LIGHT004 COMCAST005 LUMEN/CTL23'-3"\20'-6"PSENANASECONDARYFIBERNA30'-2"\22'-3"25'-4"80POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL25'-3"STREET LIGHT004 COMCAST005 LUMEN/CTL20'-2"PSE316767-166803NASECONDARYFIBERNA25'-3"23'-2"81POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'STREET LIGHT004 COMCAST005 LUMEN/CTL19'-9"PSE316752-168802NASECONDARYFIBERNA24'-8"NA82POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-6"PSE316734-166807NASECONDARYFIBERNA25'21'-1"83POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTS HOA POSITION MISCNEUTRAL25'-6"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-8"PSE316723-166801NASECONDARYFIBERNA25'-1"NA84POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITIONMISCNEUTRAL25'-4"STREET LIGHT004 COMCAST005 LUMEN/CTL19'-2"PSE316707-166801NASECONDARYFIBERNA25'-3"22'-6"85POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'STREET LIGHT004 COMCAST005 LUMEN/CTL18'-5"PSE316692-166800NASECONDARYFIBERNANA24'-4"86POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL24'-8"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-3"PSE316679-166800NASECONDARYFIBERNA21'-5"24'-9"87POWER POLE #LUMEN POLE # / A #POLE OWNERPOLE HEIGHT-CLASSPROP HOAATTACHMENTSHOAPOSITION MISCNEUTRAL25'-1"STREET LIGHT004 COMCAST005 LUMEN/CTL18'-6"PSE316664-166800NASECONDARYFIBERNA25'NAEXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P77. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P78,HEAVY TREE TRIM INSPAN.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P79, LITTLE TREE TREETRIM IN SPAN TO P79. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S NORTH.OVERLASH EXISTING STRAND/CABLE WITH F2 FOC TO P80.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P81. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P82.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P83.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P83,LITTLE TREE TRIM INSPAN TO P84. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P85.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P86. BOND TO GRND.EXISTING PWR, CATV & LUMEN. OVERLASH EXISTINGSTRAND/CABLE WITH F2 FOC TO P87. BOND TO GRND.EXISTING PWR, CATV & LUMEN DG&A'S NORTH.OVERLASH EXISTING STRAND/CABLE WITH F2 FOC.40' - 418'3"45' - 322'0"40' - 419'8"40' - 422'3"40' - 421'6"20'6"40' - 419'6"40' - 421'4"40' - 420'7"40' - 419'5"40' - 419'8"40' - 419'6"40' - 4SCALE:22SH:OF 1"=100'22 BEFORE YOU DIG811CALL TWO WORKING DAYSFIBER ENGINEERNAME:PHONE:SECTION:TOWNSHIP:RANGE:GEO CODE:NAJOB:N.981417DATE:01/25/2022NOTICE- NOT FOR DISCLOSURE OUTSIDE OF LUMEN AND AFFILIATES EXCEPT UNDER WRITTEN AGREEMENTMARIA HAYES(253) 393-53875E23N28NOTE:THE RIGHT-OF-WAY SHOWN HAS NOT BEEN SURVEYED OR TIED.RIGHT-OF-WAY LOCATION IS ASSUMED WITH REFERENCE TO ONLINE DATA SOURCE MATERIALS.CONTRACTOR TO VERIFY ALL RIGTHS OF WAY AND/OR EASEMENTS PRIOR TO CONSTRUCTION.NOTE:ALL AERIAL PLACEMENTS ARE OVERLASH ONLY UNLESS OTHERWISE NOTED.NOTE: FOR UNDERGROUND ACTIVITY: TEST AND VENTILATE MANHOLE/UTILITY VAULT PRIOR TOENTRY,PLACE WARNING DEVICES AND WORK AREA PROTECTION AS REQUIRED , AND USE EYEAND HEAD SAFETY PROTECTION PER FEDERAL, STATE, AND LOCAL REGULATIONS.EMAIL:MARIA.HAYES@LUMEN.COMCONTRACT ENGINEER NAME:PHONE:CHRISTOPHER1-940-465-4662EMAIL:Christopher.Huff@cyient.comCUSTOMER INFORMATION11635 SE 170TH PL,RENTON WA 98058, USADRAFTED BY:CYIENT INCREVISION:1CLLI:RNTNWA01MFP23001352 DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Conditions for Permit MFP23001353 Engineering 1 A traffic control plan must be separately submitted to the City, and no construction may take place until the City has approved a traffic control plan. 2 The new aerial fiber lines within the Project Reach must be converted to underground facilities in the future, at the Applicant’s cost, when any one of the following events occurs: (1) any other utilities are undergrounded within the Project Reach, (2) a joint use trench is proposed by a franchisee within the Project Reach, in which case the Applicant shall participate in the joint use trench installation for the purpose of undergrounding its aerial lines, or (3) a conduit is made available within the Project Reach that will accommodate the aerial lines. The new aerial lines must be undergrounded within one year, or approved otherwise by the City of Renton Community and Economic Development Administrator or designee, from the first event triggering the requirement to underground the aerial lines. 3 Any existing height violations within the Project Reach must be resolved at the time of construction. New aerial lines within the Project Reach must have a minimum vertical clearance of 15'-6". 4 Any abandoned or unused lines within the Project Reach must be removed at the time that construction is taking place. Page 1 of 1