Loading...
HomeMy WebLinkAboutR-422103\s IE 12" CPP=392.37 (S) IE 12" CPP=390.82 (W) 114, Irc,.. �, 8 C, C'OA �`39962s PROTECT EX CURB TO O \ RAMP TO REMAIN \ REFER TO ARCHITECT PLANS FOR PARTIAL CANOPY/BRICK COLUMN DEMOLITION SAVE AND PROTECT EX CB - PLUG EX 6" INLET (E) :MOVE AND SALVAGE EX \ AGPOLE TO BE :INSTALLED, FOUNDATION BE REPLACED EMOVE AND SALVAGE X LIGHT POLE IXTURES, FOUNDATIONS x na Q / - i i0 BE REPLACED z - - �+ Q (TYP OF 4) \ \ O SocR �! I- I S�A�M, / 1� \ // �1X2\_�X GP, N A c392s SAWCUT AND REMOVE Op,S s° 611 / EX ASPHALT LIMIT OF WORK S LLI - ------ \ 0 O \\ 75 C0 0 P=393 REMOVE EX CURB 0 � �vP T1 W Y m I / REMOVE EX 8" SEWER 0 I / (Tyl z I // J �� REMOVE EX / � \ '0 �P j CONCRETE BENCH A��^ / I Q �, REMOVE EX �, CD CONCRETE BENCH e S TP=394.85 / / SAVE AND PROTECT EX a j FIRE HYDRANT TO REMAIN 0 CATCH BASIN c`.9 NSERT (TYP) - 4 NCLOSU 5.06 s` • 4 397.72 O e ° REMOVE8 EX 6" FIRE SERVICE J CONTRACTOR TO FIELD Q / INVESTIGATE LOCATION THRU TUNNEL TO VERIFY PROPOSED e REPLACEMENT ELEVATIONS V �� / � / � v / 39 . Il i SAVE AND PROTECT EX UTILITY TUNNEL T TO REMAIN CONTRACTOR TO FIELD 8'2 / ` / LOCATE TUNNEL TO VERIFY STRUCTURE EX 398.51 / / DIMENSIONS, TOP AND BOTTOM EX EASEMENT =396.' ELEVATIONS, AND INTERNAL UTILITY PIPE 3 .16 SIZES AND LOCATION WHERE PROPOSED �/J REMOVE8 EX 8" / LINES CROSS EX :WATER LINE 6s 4 398 REMOVE EX 8" WATER LINE / P / SAVE AND PROTECT �v EXISTING PEDESTRIAN k� REMOVE EX 4" EX 398.54 WALKWAY COLUMNS AND v WATER SERVICE AND TP=395.02 FOUNDATION (TYP) / METER / 1932 First Ave 7� of W �SNi,��� Suite 201 Seattle, WA 98101 p, 206.725.1211 f. 206.973.5344 P, �F ISTER�� Fss/AN engineering pIIc www•IpdengineeriAL �E7 ng.com _1..�11N� NO. E / REMOVE EX 6" STORM PROPOSED BUILDING OUTLINE REMOVE EX BIKE RACKS AND GARBAGE CAN 0 �e d REFER TO MECHANICAL PLANS FOR EX GAS LINE DEMOLITION AND REPLACEMENT NOTES: 1. CIVIL PLANS SHOWN AND NOTED WERE TAKEN FROM EXISTING DRAWINGS AND FIELD SURVEY. 2. AT PROPOSED CONNECTION POINTS TO EXISTING UTILITIES, CONTRACTOR TO POTHOLE TO CONFIRM LOCATION AND ELEVATION OF UTILITIES PRIOR TO CONSTRUCTION. 3. PROVIDE MINIMUM OF 12,900 GALLON CAPACITY (NORTH DISTURBANCE AREA) AND 24,200 GALLON CAPACITY (SOUTH DISTURBANCE AREA) BAKER TANKS AS NECESSARY FOR STORMWATER SEDIMENT SETTLING PRIOR TO DISCHARGE FROM SITE. 4. UTILIZE EXISTING FENCING AND/OR PROVIDE CONSTRUCTION FENCING AS NECESSARY TO SECURE SITE. 5. PROVIDE CATCH BASIN INSERTS 500 FEET DOWNSTREAM OF SITE AND ALONG ROUTE PER COR STD PLAN 216.30. 6. REFER TO MECHANICAL PLANS FOR GAS ADDITIONAL UTILITY AND RAIN LEADER DEMOLITION NOTES. 7 THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE THE MINIMUM PROVIDE TEMPORARY STORM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS AS CONSTRUCTION ROUTING FOR OVERFLOW DRAIN S PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE. THE APPLICANT CO TO NEAREST CB SHALL ANTICIPATE THAT MORE ESC BMPS SHALL BE IMPLEMENTED TO ENSURE COORDINATE WITH MECHANICAL COMPLETE SILTATION AND EROSION CONTROL ON THE SITE PER THE CONSTRUCTION FOR INTERNAL REROUTING STORMWATER POLLUTION PREVENTION PLAN. CAP AND ABANDON 6" SEWER A13OVE UNDERNEATH BUILDING FILL PIPE WITH CDF OR STRUCTURAL FOAM REMOVE EX BRICK PAVING PLAQUES COORDINATE WITH LANDSCAPE SDCB, RIM=397.17 ARCHITECT FOR REPLACEMENT IE 6" PVC=395.93 (NE) SAVE AND PROTECT EX IE 6" PVC=395.93 (SE) COLUMNS TO REMAIN IN 7.73 PLACE DOOR." -; REMOVE EX 6" SEWER CAP AND ABANDON 8" STORM (Tyl REMOVE EX SEWER MANHOLE UNDERNEATH BUILDING ABANDON EX SEWER MANHOLE CONTRACTOR TO FILL PIPE WITH CDF OR CONFIRM NO OTHER FLOWS INTO SYSTEM STRUCTURAL FOAM CONTRACTOR TO COORDINATE WITH OWNER 39 PRIOR TO TAKING SYSTEM OFFLINE DOOR.35 SSMH, RIM=397.5 SSMH SHALL BE BROKEN DOWN TO A DEPTH REMOVE EX BENCH MID CHANNEL= 0.11 (SE,SE-NW) OF AT LEAST 4-FEET BELOW PROPOSED FLOOR B r-REMOVE EX CB ALLCONNECTIONS SHALL BE PLUGGED AS REMOVE EX CONCRETE (Tyl EX 399. CONCRETE SAWCUT EX CONCRETE @ NEAREST - /JOINT, JOINT LOCATIONS ARE APPROXIMATE. FIELD VERIFY EXTENT OF CONCRETE PANEL REMOVAL (TYP) CIVIL PERMIT RESPONSE PERMIT RE -SUBMITTAL REVISION SURVEYED: DESIGNED: 0/26/2 DRAWN: 2/ 1 2/2 JCHECKED: BY DATE AP P R APPROVED: NECESSARY SSMH SHALL BE FILLED WITH STRUCTURAL FOAM TO 90% DENSITY COORDINATE WITH MECHANICAL FOR INTERNAL SEWER REROUTING REMOVE EX BENCHES 412.78 DOOR.34 -PROPOSED BUILDING REMOVE EX OUTLINE RETAINING WALL SSMH IM=400.81 MI CHANNEL-- on.5-7 / REMOVE EX 6" SEWER AND SEWER MANHOLE REMOVE EX 8" STORM 401 .76 D00 . 3 OVERFLOW DRAINS f SAVE AND PROTECT EX PIV 401.81 DOOR.32 \ -, 1�y. 2" \ \ 6,> \ A \ a99- i / 400. REMOVE EX 8" SEWER / \ (TYP) SAVE AND PROTECT EX CB PLUG EX 8" OUTLET C1•9 o / 62 o \ s \ SCALE: VERTICAL: NAVD 1988 CITY O F HORIZONTAL: NAD 1983/183/1991 RENTON ONE INCH DATU M AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY 0 10 0 N 5 10 20 CD O i N Q J Scale 1"=10' LEGEND - - PROPERTY LINE -230 _ EX CONTOUR (INDEX) 00 co EX CONTOUR O C) / EX BUILDING l 1 PROPOSED BUILDING OUTLINE BUILDING/STRUCTURE REMOVAL NN L.L ���� � SAWCUT LINE � ASPHALT REMOVAL CONCRETE REMOVAL STABILIZED CONSTRUCTION ENTRANCE 0 EX TREE TO REMAIN v EX TREE TO BE REMOVED TREE PROTECTION Cfl Ln . . . . . EX CURB TO BE REMOVED 00 NQ So EX UTILITY TO BE REMOVED CATCH BASIN INSERT N N LIMITS OF WORK (� KEY MAP N � Know what's below. � Call before you dig. Dial 811 R-422103 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Q Michael Sippo 01/27/2023 ' < LINDBERGH HIGH SCHOOL MODERNIZATION 16426128TH AVE SE RENTON, WA 98058 TESC + DEMOLITION PLAN AREA A-ADMIN 11­ 75 m Z) DATE. 16 SEPT 2022 W FIELDBOOK: PAGE: (- DRAWING NO: C1.1 W SHEET: 3 OF. 64