Loading...
HomeMy WebLinkAboutR-422105N CD W I— W REMOVE PORTION OF EX 4" SEWER Z REFER TO MECHANICAL PLANS FOR O ADDITIONAL DEMOLITION NOTES 0 0 Q 0 Q z O RBI Q \ N \ Z ` ry �� \ LU O 7 \ C0 o 00 20 ry LJJ m 0 Z \ 7» J \ /z RIM=413.17 — '" CPP=408.67 (NE) >" CMP=403.77 (SE) PVC=406.95 (SW) PVC=409.37 (NW) 4' CHAIN LINK FENCE w Q z w U_ SAVE AND PROTECT EX STORM STAIRS TO REMAIN GAS RISER W/ FENCE lxLl L1\ I V lvlLVl lmlllVML_ PLANS FOR EX GAS "'-,LINE ABANDONMENT AND REPLACEMENT J -/ 1932 First Ave Suite 201 I m Seattle, WA 98101 e p, 206.725.1211 f. 206.973.5344 engineering pllc www.lpdengineering.com 'r=4vy. i4'l`�vl 'P=4f� 5/7 (SE� SAVE AND PROTECT EX \ STORM MANHOLE \ PLUG EX 12" INLET (SE) SAVE AND PROTECT FX I I(:NT PnI F SAVE AND PROTECT EX WATER MAIN TO REMAIN (TYP) SAVE AND PROTECT \ EX FRENCH DRAIN \ REMOVE EX ELECTRICAL LINES SEE ELECTRICAL (TYP) \ SDCB, RIM,=426.93 IE 6" PVC111=423.18 (NE) \ IE 8" PVC 2 2.3 5 (SE) \ \ \ � 7/ 1___1 \ \ SAVE AND PROTECT EX — / LIGHT TO REMAIN 0 m CIVIL PERMIT RESPONSE 7 PERMIT RE —SUBMITTAL NO. REVISION CATCH BASIN ( \ INSERT (TYP) C1.9 \ PROPOSED BUILDING \ OUTLINE \ \ SAVE AND PROTECT EX CONCRETE WALK AND STAIRS TO REMAIN O NOTES: 1. CIVIL PLANS SHOWN AND NOTED WERE TAKEN FROM EXISTING DRAWINGS AND FIELD SURVEY. 2. AT PROPOSED CONNECTION POINTS TO EXISTING UTILITIES, CONTRACTOR TO POTHOLE TO CONFIRM LOCATION AND ELEVATION OF UTILITIES PRIOR TO CONSTRUCTION. 3. PROVIDE MINIMUM OF 12,900 GALLON CAPACITY (NORTH DISTURBANCE AREA) AND 24,200 GALLON CAPACITY (SOUTH DISTURBANCE AREA) BAKER TANKS AS NECESSARY FOR STORMWATER SEDIMENT SETTLING PRIOR TO DISCHARGE FROM SITE. 4. UTILIZE EXISTING FENCING AND/OR PROVIDE CONSTRUCTION FENCING AS NECESSARY TO SECURE SITE. 5. PROVIDE CATCH BASIN INSERTS 500 FEET DOWNSTREAM OF SITE AND ALONG ROUTE PER COR STD PLAN 216.30. 6. REFER TO MECHANICAL PLANS FOR GAS ADDITIONAL UTILITY AND RAIN LEADER DEMOLITION NOTES. 7. THE ESC BMPS DEPICTED ON THIS DRAWING ARE INTENDED TO BE THE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE. THE APPLICANT SHALL ANTICIPATE THAT MORE ESC BMPS SHALL BE IMPLEMENTED TO ENSURE COMPLETE SILTATION AND EROSION CONTROL ON THE SITE PER THE CONSTRUCTION STORMWATER POLLUTION PREVENTION PLAN. 0 NC) O N N Q 10 0 5 10 20 I I I I I J LEGEND Scale 11111=10, — — PROPERTY LINE EX CONTOUR (INDEX) 00 �— M —23l— _ _ _ EX CONTOUR O O EX BUILDING O � PROPOSED BUILDING OUTLINE N \ � BUILDING/STRUCTURE REMOVAL N � �� — SAWCUT LINE \ \ ASPHALT REMOVAL \ CONCRETE REMOVAL \ STABILIZED CONSTRUCTION \ ENTRANCE \ EX TREE TO REMAIN EX TREE TO BE REMOVED TREE PROTECTION Cfl Ln . . . . . EX CURB TO BE REMOVED 00 N SD EX UTILITY TO BE REMOVED O 13 O i 1�\\ CATCH BASIN INSERT N LIMITS OF WORK U \ 1 1 1 I I I F I \ I � I I SAVE AND PROTECT EX STORM LINE TO REMAIN (TYP) 26„ -SAVE AND PROTECT EX I CB IB, RIM=42L.60 1 I 1 9 2" CPP=4h 9.52 (NW) 1 1 I IE �" CPP=41 f.80 (SE) SAVE AND PROTECT I IN, \ EX POWER TO REMAIN 1 REFER TO MECHANICAL PLANS FOR EX GAS LINE ABANDONMENT AND REPLACEMENT / / —SAVE AND PROTECT EX STORM TO REMAIN SURVEYED: DESIGNED: 0/26/2 DRAWN: 2/ 1 2/2 CHECKED: BY DATE I AP P R APPROVED: SCALE: I I I \ 1 I ISDC� Ri)-\422.44 k 8" PVC= 18.57 (NW) \ IE\ 12" CPP=4�8.44 (SW) ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATU M CITY OF s RENTON Planning/Building/Public Works Dept. KEY MAP N Know what's below. i& Call before you dig. Dial 811 R-422105 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING Q Michael Sippo 01 /27/2023 LINDBERGH HIGH SCHOOL MODERNIZATION 16426128TH AVE SE RENTON, WA 98058 TESC + DEMOLITION PLAN AREA F3- SOUTH SCIENCE m Z) DATE. 16 SEPT 2022 LU FIELDBOOK: (- PAGE: DRAWING NO: C1.3 LJJ SHEET: of: 5 64