Loading...
HomeMy WebLinkAboutzR-4253setM Lii N O� 0 W PROJECT TEAM OWNER: ENGINEER: SURVEYORS: KUSHAL VARMA 1518 JERICHO PL NE RENTON, WA 98059 (206) 353-3168 NICOLE MECUM, PE G2 ClVIL 1700 NW GILMAN BLVD, SUITE 200 ISSAQUAH, WA 98027 (425) 821-5038 KEVIN REESE, PLS M ENCOMPASS ENGINEERING & SURVEYING LLi 165 NE JUNIPER ST, SUITE 201 N ISSAQUAH, WA 98027 (425) 392-0250 ti (V EVAN WAHLSTROM, PLS INFORMED LAND SURVEY a 3215S12THST TACOMA, WA 98405 (253) 678-2539 BIOLOGIST. JOHN ALTMANN ALTMANN OLIVER ASSOCIATES, LLC PO BOX 578 CARNATION, WA 98014 (425) 333— 4535 GEOTECHNICAL KRISTINA WELLER, PE ENGINEER: THE RILEY GROUP 17522 BOTHELL WAY NE BOTHELL, WA 98011 (425) 415-0551 ARBORIST. BOB LAYTON LAYTON TREE CONSULTING, LLC PO BOX 572 SNOHOMISH, WA 98291-0572 (425) 220-5711 3 HORIZONTAL DATUM NAD 83191 PER CITY OF RENTON CONTROL NETWORK BASIS OF BEARINGS BASIS OF BEARING: HELD THE BEARING OF S 8821'40" E PER ROS 192160 BETWEEN THE ABOVE NOTED BASIS OF POSITION AND THE NORTHEAST CORNER OF SECTION 14-23N-5E AND ROTATED — 1 °11'57" (S 87°09'43'E) TO BE ON THE ABOVE NOTED HORIZONTAL DATUM. SEE TOPOGRAPHIC SURVEY MAP BY OTHERS FOR LOCATION AND DESCRIPTION. VERTICAL DATUM NA VD 88 BENCHMARK MASTER BENCHMARK: CITY OF RENTON SURVEY CONTROL POINT #2103 — A FOUND 3" BRASS DISK AT THE INTERSECTION OF SE 128TH STREET AND 156TH AVENUE SE. ELEVATION = 547.94 FEET SITE BM #1: SET MAG NAIL NEAR WEST EDGE OF 156TH AVENUE SE, 0.5 FEET EAST OF THE WEST EDGE OF PAVEMENT AND 6.5 FEET SE OF A MAILBOX. ELEVATION = 529.05 FEET SITE BM #2: SET MAG NAIL ON EAAST SIDE OF 158TH AVENUE SE 0.4 FEET WEST OF THE EAST EDGE OF PAVEMENT AND 28.5 FEET SW OF A UTILITY POLE. ELEVATION = 533.56 FEET INSTRUMENTATION TRAVERSING AND DATA COLLECTION WERE PERFORMED USING A 5 SECOND TOTAL STATION. ALL FIELD WORK WAS PERFORMED AND EQUIPMENT MAINTAINED IN COMPLIANCE WITH WAC 332-130. LEGAL DESCRIPTION PARCEL #3664500185 PARCEL A: THE NORTH HALF OF THE WEST HALF OF TRACT 2, BLOCK 2, JENNET'S RENTON BOULEVARD TRACTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 17 OF PLATS AT PAGE 60, RECORDS OF KING COUNTY, WASHINGTON. EXCEPT THE NORTH 130 FEET OF THE WEST 115 FEET THEREOF. PARCEL B THE WEST HALF OF THE SOUTH HALF OF LOT 2, BLOCK 2, JANNETT'S RENTON BOULEVARD TRACTS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 17 OF PLATS, PAGE 60, RECORDS OF KING COUNTY, WASHINGTON. SITUATE IN THE COUNTY OF KING, STATE OF WASHINGTON. Know what's below. Call before you dig. SITE DATA SITE ADDRESS: 13014 156TH AVE SE RENTON, WA 98059 PARCEL NUMBER: 366450-0185 SITE AREA EXISTING: 46,759 SF (1.07 AC) SITE AREA PROPOSED: 45,872 SF (1.05 AC) ZONING: RESIDENTIAL-4 (R-4) SCHOOL DISTRICT. RENTON #403 UTILITY DISTRICT INFORMATION WATER: KING COUNTY WATER DISTRICT 90 (425) 255-9600 SEWER: CITY OF RENTON (425) 430— 7204 FIRE DISTRICT.' RENTON REGIONAL FIRE AUTHORITY (425) 430— 7000 CABLE TV. COMCAST (800) 934-6489 GAS/ELECTRIC: PUGET SOUND ENERGY (888) 321-7779 EXISTING UTILITY NOTE ALL LOCATIONS OF EXISTING UTILITIES SHOWN HEREON HAVE BEEN ESTABLISHED BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR RESPONSIBILITY CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, AND THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. DISCLAIMER PORTIONS OF THE INFORMATION ON THIS DRAWING HAVE BEEN CREATED USING A SUBSET OF DATA OBTAINED FROM THE KING COUNTY GIS DATABASE, AND HAS NOT BEEN INDEPENDENTLY VERIFIED BY G2 CIVIL. THIS DATA IS PROVIDED FOR YOUR INFORMATION ONLY. G2 CIVIL DOES NOT ASSUME ANY LIABILITY FOR ANY ERRORS, OMISSIONS OR INACCURACIES IN THE GIS INFORMATION SHOWN. DISCREPANCIES IF THERE ARE ANY DISCREPANCIES BETWEEN DIMENSIONS IN DRAWINGS AND EXISTING CONDITIONS WHICH WILL AFFECT THE WORK, THE CONTRACTOR SHALL BRING SUCH DISCREPANCIES TO THE ATTENTION OF THE ENGINEER FOR ADJUSTMENT BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER FITTING OF ALL WORK AND FOR THE COORDINATION OF ALL TRADES, SUBCONTRACTORS, AND PERSONS ENGAGED UPON THIS CONTRACT. 1700 NW GILMAN BLVD, STE 200 IVIL ISSAQUAH, WA 98027 PHONE: (425) 821-5038 03116120231 NO. VARMA SFR FRONTAGE IMPROVEMENTS NW 1/4 OF NE 1/4 OF SECTION 14, T. 23 N., R. 05 E., W.M. CITY OF RENTON, KING COUNTY WASHINGTON TAX PARCEL 142305-9071 VACANT KING COUNTY PARKS RENTON ZONING R-4 I TAX PARCEL 142305-9116 15514 SE 132ND ST, RENTON 98059 RENTON ZONING R-4 REVISION ------- ------------ +80............50 00 — — — — — — -------- ::: a: ALL WORK TO BE DONE ON THE PARCEL .{. TO BE REVIEWED :•:..... . .... . ..:I:.:..:. -I. UNDER SEPARATE BUILDING PERMIT • • •'.'I • • .'•1_ f I EXCEPT AS NOTED. TAX PARCEL 366450-0184 13010 156TH AVE SE RENTON ZONING R-4 GRAPHIC SCALE 20 0 10 20 SCALE: 1" = 20' 0 NE 4TH ST z p W SITE Q 0 W Z NE 2ND ST Q cW„ U SQ Cc NE 1ST ST 41 SE 2ND ST Q SE 2ND CT co to SE 2ND PL VICINITY MAP NOT TO SCALE PROPOSED VARMA LOT 1 NTS 1 J N LO r O M N Alu O O N a J U) SHEETINDEX ~ Z 1. COVER SHEET LU 2. TESC PLAN/TREE RETENTION PLAN 2 3. SITE GRADING, DRAINAGE & UTILITY PLAN LU 4. CONSTRUCTION DETAILS O 5. CONSTRUCTION DETAILS & NOTES li S-425301 I R-425301 IN COMPLIANCE WITH CITY OF RENTON STANDARDS LU CURRENT PLANNING �' DEVELOPMENT ENGINEERING AWeihs 04/20/2023 I SAMorman 04/20/2023 ' Z p W LL C DATE: L L CITY 0 I 03/16/2023 in R E N TO N VARMA SFR FRONTAGE IMPROVEMENTS PAGE: N/A a PAGE. DMWING NO: Planning/Building/Public Works Dept. COVER SHEET SHEET: OF. 1 5 B21000376 ti N LO r O O M N Al d� O O O r N a J cn H z W W > O w a 2 w O a z O w U. w U. cn a a B21000376 _ W IEGfICSYIIEi'�EvgaR RNAPfi . MIY YAI! :[E (ATE t_ a LYE Iftm morf E Esat w1p �. 1a LIW •aYEY pM 4Yl�r �eaJWE7 J4 e.l ImA s xlwr errr.( (�>; TD'win tul I .41 1 k l � R• uarvn3 E � �rvF r,rt.F ■I �� METE 1�fE � [.f°!Nl [M[11E1E AA.r n1n.1Tn 1v B e+ae L oLnTaa eIDPEIIYA 1 :SITE NOTR 7 u-poe.f.Au�arac.a Rv,I ME-ST9 R+N I'Jtt PLAN 1FiEW _ v.lrts ,4f ftmr IA " M,In WE.'fFE NGl[Ni RS1y ��•� L c cm. r .. ;.�s��No �ii :araaoutfu .� 'LMr exP4AooN cwrr Irro I $EGTKIN aEeim 1•IAN Tri. 4 . -w Rm. - _ mEnMUIMKITM mFlrAer,e:c IN l:ic.Eew 1 . /-.C% �_-T1RfITISArwPDsm�,e iLOPE b%L DRE ■VM]Y/Ic.Anrnlu*EEh r _ t i pnrxtiY.L w.IM!,N1M12 �. r- �° I� S�jb1N a NECw11/�IL 6iAf c [R'�'. . /1 cgmn LpLWaIK TYPE RIB - ISOMETRIC VIEW {RESIDENTLAL WITH BUFFER) caha NT 137N,ilrL 1E ,"401 =n For NOTES STD- PLAN 104.2 0 sm. PLAN - 104"3 �- PUBLIC DEPARTMPNTS CEMENT CONCRETE ENTRANCE - TYPE RIB AY �FFti I"i? za° ' 1/2" L BOLT -DOWN SLOT, 3I4„ SEE DETAIL AND I 1. 2 1/2" DIA. HOLE NOTE 1 1 1/4 / J' 201. A 5/8" O r �000�oo I Q000p00000 BOLT -DOWN SLOT DETAIL L _ _ _ SEE NOTE 1 - - 3„ TOP ro ISOMETRIC R26", SEE NOTE 2 i L4 114" 1 111" 1 5/8f MAX. " R39', SEE NOTE 2 12-. OR 24- ONE 03 BAR HOOP FOR 6' HEIGHT INCREMENT (SPACED EQUALLY). SP.F Nl±'F RECTANGULAR ADJUSTMENT SECTION 'LG �00 fF Fe i IaN / I i $ -3 BAR EACH CORNER I i I� 1 #3 BAR EACH SIDE J.J: �✓ "v 03 BAR EACH WAY PRECAST BASE SECTION 03 BAR HOOP #38AREACH CORNER 18" MIN, SEE NOTE I ALTERNATIVE PRECAST BASE SECTION a PUBLIC WORKS PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN CONCRETE 12' ALL METAL PIPE 15, CPSSP", STD. SPEC. 9-05'0 12' SOUD WALLPVC. STD. SPEC. 9-05.12(1) 15" PROFILE WALL PVC, STD. SPEC, 9415.12(2) tb 'CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1. AS ACCEPTABLE ALTERNATIVES TO THE RESAR SHOWN IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9.05.5019)), OR WIRE MESH HAVING A MINIMUM AREA OF a 12 SONRE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS, AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 2D". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2 5" MAXIMUM PROVIDE A 1 5" MINIMUM OAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE AFTER THE PIPE IS INSTALLED. FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9.043. 3, THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1H24V OR STEEPER S. THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7, ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 420.312) B. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9•QI 3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS. RINGS. RISERS. AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH 11 ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION, UNLESS OTHER W t5E NOTED, DRAWING 15 NOT TO SCALE (NTS) STD. PLAN - 200.00 _� APPR D 1� DEPARTMENT CATCH BASIN TYPE i GAZ 9/28/2018 I DATE W ISOMETRIC 24" 7 OR 8 EQUAL SPACES ITT DIRECTION FLOW 1 5/8" MAX. J 5„ NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, 5/g• GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8%11 NC x 2" ALLEN 4" HEAD CAP SCREW BY BEING TAPPED OR OTHER .4" DIA. HOLE APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES 1 1/2" DIA. HANDLE VARIES 8Y MANUFACTURER. J_ 1 1/2" 2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN SECTION C LIEU OF THE RIB DESIGN. 3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 204.10 a } PUBLIC WORKS ° � PUBLIC WORKS .o. 3 DEPARTMENT RECTANGULAR SOLID METAL COVER GAZ 9/28/2018 1 IR DEPARTMENT Q {� v"n°mw"rrs admm:r,x". DATE W 0 I 3 2 a 0 Q Q 0 Y i I I I OLT-DOWN SLOT, I1/2" EE DETAIL AND OTE 1 3/4' 1 1/4" I � I I TI I I I I BOLT -DOWN SLOT DETAIL L _ _ _ SEE NOTE 1 LETTERING SECTION B NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES GRATES AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3. FOR FRAME DETAILS, SEE STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS) STD. PLAN - 204.20 RECTANGULAR VANED GRATE 7ZAz9/28/2018 1 DATE 1700 NW GILMAN BLVD, STE 200 CIVIL ISSAQUAH WA 98027 Know what's below. PHONE: (425) 821-5038 Call before you dig. Lill Ei 03116120231 NO. CATCH BASIN FRAME AND VANED GRAE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) MORTAR, (TYP.), SEE NOTE 5 4" MIN. 28" MAX, 16" MAX. FLAT SLAB TOP 48", 54", 60", 72", 84", 96", 120" OR 144" SEE NOTE 6, TYP. 15' MAX. FOR MAINTENANCE STEPS OR LADDER L- 12" (TYP.) �o L- T 1" MIN. "O" RING' 2.5" MAX. REINFORCING STEEL, (TYP.) IN24" MIN. 12" a 12" MAX. GRAVEL BACKFILL FOR PIPE ZONE 12" BEDDING PER WSDOT STD. SPECIFICATION SECTION 9-03.12(3) 6" 6" SEPARATE BASE INTEGRAL BASE PRECAST PRECAST WITH RISER NOTES: 1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3. THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPEUSE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. • PUBLIC WORKS DEPARTMENT REVISION CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48" 4" 6" 36" 8" 54" 4.5" 8" 42" 8" 60" 5" 8" 48" 8" 72" 1 6" 18" 60" 12" 84" 8" 12" 72" 12" 96" 8" 12" 84" 12" 120" 10" 12" 96" 12" 144" 12" 12" 108" 12" PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL CPSSP 1 SOLID WALL PVC, PROFILE WALL PVC' 48" 1., 30" 1. 30" 30" 54" 30" 36" 30" 36" 36" 60" 36" 42" 36" 42" 42" 72" 42" 54" 42" 48" 48" 84" 1.. 60" 54" 48" 48" 96" 60" 72" 601.1 48" 48.1 120" 66" 84" 60" 1 48" 48" 144" 78" 96" 60..1 48" 48" 1 CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) 'STD. SPEC. 9-05.12(1) t STD. SPEC. 9-05.12(2) SEE NOTE 4 CLEAN SURFACE AND BOTTOM AREA. / PROVIDE UNIFORM CONTACT. THE SURFACE AREA OF THE BASE SECTION MUST BE /Y MORTARED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION ADJUSTMENT SECTION I I I I I I I I NOTES: 1. THE COVER OR GRATING OF A CATCH BASIN SHALL NOT BE ADJUSTED TO FINAL GRADE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER, DITCH, OR SIDEWALK IN WHICH IT IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER IS GIVEN BY THE ENGINEER TO MORTAR IN PLACE IN ACCORDANCE WITH WSDOT/APWA STANDARD SPECIFICATION 7-05.3. 2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE. THE USE OF SHIMS IS PROHIBITED. 3. A CONTINUOUS LAYER OF MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMENT. 4. ONLY BY APPROVAL OF THE CITY, THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND ORY BOND. 5. BASE SECTION SHALL BE SEALED TO THE BOTTOM AREA OF THE ADJUSTMENT SECTION WITH MORTAR. 6. MORTAR SHALL MEET THE REQUIREMENTS OF WSDOT/APWA STANDARD SPECIFICATION 9-04.3. 7. PICK / LIFTING HOLES ARE TO BE GROUTED WATER TIGHT. USE GROUT TYPE 2 FOR NON -SHRINK APPLICATIONS IN ACCORDANCE WITH STANDARD SPECIFICATION 9-20.3(2). 8. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 9. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 10. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NT5) STD. PLAN - 201.00 PRo D: o PUBLIC WORKS CATCH BASIN TYPE 2 GAZ 9/28/2018 1 DEPARTMENT v"el,r w"n: nam,",mx"r DATE 5" MAX. DRAINAGE GRATE TRIM GRATE FRAME C- OVERFLOW BYPASS BELOW INLET GRATE DEVICE SEDIMENT AND DEBRIS FILTERED WATER SECTION VIEW ORWNAGE GRATE IRECTANGULAR GRATE SHOWN) RETRIEVAL SYSTEM ITYP ) m OVERFLOW BYPASS (TYP ) / BELOW INLET GRATE DEVICE ISOMETRIC VIEW NOTES: : iI TECTKIN SHALL BE PROVIDED FOR ALL STORM DRAIN INLETS DOWNSLOPE AND WITHIN 500 FEET OF A DISTURBED OR CONSTRUCTION AREA. UNLESS THE RUNOFF THAT ENTERS THE CATCH BASIN WILL BE CONVEYED TO A SEDIMENT POND OR TRAP. 2 INLET PROTECTION SHALL BE USED TO PROTECT THE DRAINAGE SYSTEM 3. THE CONTRIBUTING DRAINAGE AREA MUST NOT BE LARGER THAN ONE ACRE 4 SIZE THE BELOW INLET GRATE DEVICE 7B1GD1 FOR THE STORMWATER STRUCTURE IT WILL SERVICE 5. THE BIGD SHALL HAVE A BUILT-IN HIGF4FLOW RELIEF SYSTEM (OVERFLOW BYPASS) 6 THE RETRIEVAL SYSTEM MUST ALLOW REMOVAL OF THE GIGO WITHOUT SPILLING THE COLLECTED MATERIAL. I PERFORM MAINTENANCE IN ACCORDANCE WITH STANDARD SPECIFICATION "1,3115) 8 ANY SEDIMENT W THE CATCH BASIN INSERT SHALL BE REMOVED WHEN THE SEDIMENT HAS FILLED ONE-THIRD OF THE AVAILABLE STORAGE THE FILTER MEDIA FOR THE INSERT SHALL BE CLEANED OR REPLACED AT LEAST MONTHLY UNLESS OTHERWISE NOTED DRAWING IS NOT TO SCALE (NTS', STD. PLAN - 216.30 PUBLIC WORKS ° DEPARTMENT CATCH BASIN INSERT GAZ 9/28/2018 I d1t DESIGNED: EDM DRAWN: TLK CHECKED: EDM BY DATE APPR APPROVED: NEM RECESSED ALLEN HEAD CAP SCREW 5l8"-11 NC x 2" GRATE FRAME r I SECTION BOLT -DOWN DETAIL SEE NOTE 2 TOP 24 114" SECTION A SEE DETAIL ISOMETRIC VIEW 718" \ / 3/4" \ I 11/4" I NOTES: 1. THIS FRAME IS DESIGNED TO ACCOMMODATE 20" x 24" GRATES OR COVERS, 4 1/2" SEE STANDARD PLANS 204.10, 204.20, AND 204.30. I 1 5/8" I 2. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PR/ FRAME THAT ARE VERTICALLY ALIGNED WITHODE THIE GRATE OR COVER SLOTS. TWO HOLES IN THE 1 5/8 THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY 3/4" / BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF \ / BOLT -DOWN HOLES VARIES BY MANUFACTURER. � 2 112" � 3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL \ DETAIL REQUIREMENTS. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) D. PLAN - 202.00 PRo a } PUBLIC WORKS CATCH BASIN INSTALLATION GAZ 9/28/2018 DEPARTMENT DATE JOINTS IN FILTER FABRIC SHALL BE SPLICED POSTS. USE STAPLES, WIRE RINGS, OR EQUIVALENT TO ATTACH FABRIC TO POSTS AT 1 2'.r M GAUGE WIRE. OR - - - - EQUIVALENT. IF STANDARD I- -. --1- STRENGTH FABRIC USED - FILTER FABRIC -_--_-__---J.j_- It C•MAX . 12" MIN'MAY SE INCREASED DPOST SPACING U I OMORE BACKING S USED I I 4"x4' MIN TRENCH J BACKFILL TRENCH WITH NATIVE SOIL OR NV TO I-12' WASHED GRAVEL 2"x4' WOOD POSTS. STEEL FENCE POSTS.OR EQUIVALENT (TYP I NOTES: 1. CONDITIONS OF USE 1.1 SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS 1.2- SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS IT INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CONCENTRATED FLOW MUST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND 2. DESIGN AND INSTALLATION SPECIFICATIONS 1 THE GEOTEXTILE USED MUST MEET THE STANDARD LISTED BELLOW A COPY OF THE MANUFACTURER'S FABRIC SPEGFICATONS MUST BE AVAILABLE ON SITE ADS (ABTA 04751) 30-IDO SIEVE SIZE (060.0 15-) FOR SILT FILM 50-t00 SIEVE SIZE 10-3D.0 ISIT n) FOR OTHER FABRICS WATER PERMITTIVITY (ASTM D4491) D 02 SEC' MINIMUM GRAB TENSILE STRENGTH (ASTM D4632) 180 LBS MIN FOR EXTRA STRENGTH FABRIC 100 LBS. MIN. FOR STANDARD STRENGTH FABRIC GRAB TENSILE ELONGATION (ASTM D4632) 30%MAX (WOVEN) ULTRAVIOLET RESISTANCE (ASTM D43551 70% MIN. 2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE WIRE BACKING OR CLOSER POST SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE 2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 214 W 2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4"X4" TRENCH MAY BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE FABRIC IS WELL BURIED ANC SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FENCE. 2.5. FILTER FABRIC FENCES SHALL BE INSTALLED ALONG CONTOURS WHENEVER POSSIBLE. 3. MANRENANCE STANDARDS 3.1 ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY 32IF CONCENTRATE FLOWS ARE EVIDENT UPHILL OF THE FENCE THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND 33T IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE IF THIS OCCURS. REPLACE THE FENCE OR REMOVE'IHE TRAPPED SEDIMENT 3.4 SEDIMENT MUST BE REMOVED WHHEN SEDIMENT IS 01NCHES HIGH 3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED UNLE SS OTHTRN• F NOTTD DRAWING IS NOT TO SCA.F, N" STD. PLAN - 214.00 „ PUBLIC WORKS DEPARTMENT SILT FENCE GAZ 9/28/2018 SCALE: NTS ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM %R CITY OF RENTON vamff Planning/Building/Public Works Dept. UNLESS OTHERWISE NOTED, DRAWING 15 NOTTO SCALE (NTS) STD. PLAN - 204.00 APPROVED: RECTANGULAR FRAME °' "°' Martin Pastucha 10/19/2022 P"eu. wonmeaa°o1"r DATE ET-15'1 80pD R=25'MIN INSTALL DRIVEWAY CULVERT IF THERE IS A ROADSIDE DITCH PRESENT, AS PER CITY ROAD STANDARDS 4".8" QUARRY SPALLS -� GEOTEXTILE 1 DRIVEWAYS SHALL BE PAVED TO THE EDGE OF THE RIGHT-OF-WAY PRIOR TO INSTALLATION OF THE CONST RUCTION ENTRANCE TO AVOID DAMAGING OF THE ROADWAY 2 IT IS RECOMMENDED THAT THE ENTRANCE BE CROWNED SO THAT RUNOFF DRAINS OFF THE PAD 15' MIN PROVIDE FULL WIDTH OF INGRES&EGRESS AREA 12" MIN THICKNESS NOTES: 1. CONDITION OF USE I 1 CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,0DO FEET OF THE SITE, FOR RESIDENTIAL CONSTRUCTION PROVIDE STABILIZED CONSTRUCTION ENTRANCES FOR EACH RESIDENCE IN ADDITION TO THE MAIN SUBDIVISION ENTRANCE STABILIZED SURFACES SHALL BE OF SUFFICIENT LENGTWWIDTH TO PROVIDE VEHICLE ACCESSrPARKING. BASED ON LOT SIZEICONFIGURATKNN 2. DESIGN AND INSTALLATION SPECFICATIONS I, A SEPARATION GEOTEXTILE SHALL BE PLACED UNDER THE SPALLS TO PREVENT FINE SEDIMENT FROM PUMPING UP INTO THE ROCK PAD. THE GEOTEXTILE SMALL MEET THE FOLLOWING STANDARDS GRAB TENSILE STRENGTH (ABTA D4632) 200 LBS. MIN. GRAB ENSILE ELONGATION IASTM D46321 30 % MAX, (WOVEN) CBR PUNCTURE STRENGTH (ASTM D62411 495 LBS MIN ADS (ASTM D4751) 20-4S M S STANDARD SIEVE SIZE) 2.2 DO NOT USE CRUSHED CONCRETE, CEMENT, OR CALCIUM CHLORIDE FOR CONSTRUCTION ENTRANCE STABLIZATION BECAUSE THESE PRODUCTS RAISE pH LEVELS IN STORMWATER AND CONCRETE DISCHARGE TO SURFACE WATERS OF THE STATE IS PROHIBITED. 23, HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN AREAS THAT WILL NOT BE USED FOR PERMANENT ROADS HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS THE INSPECTOR MAY AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BERG TRACKED ONTO PAVEMENT OR IF THE HOC FUEL IS BEING CARRIED ONTO PAVEMENT 24. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE 2.5 WHENEVER POSSIBLE, T14E ENTRANCE SHALL BE CONSTRUCTED ON A FIRM. COMPACTED SUBGRADE THIS CAN SUBSTANTIALLY INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE MAINTENANCE STANDARDS 'I I. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS 3 2. IF THE ENTRANCE I NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO PAVEMENT THEN ALTERNATIVE MEASURES TO KEEP THE STREETS FREE CF S S SEDIMENT HA E USED THIS MAY INCLUDE STREET SWEEP( AN INCREASE IN THE DIMENSIONS OF THE ENTRANCE, R THE INSTALLATION OF A WHEE_ S LLB U SWEEPING, CREAS N9 E E. Q E KJN WASH IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH CRUSHED ROCK, AND WASH WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND 33 ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET. EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT IS NECESSARY TO WASH THE STREETS, A SMALL SUMP MUST BE CONSTRUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND DISCHARGED APPROPRIATELY. WASH WATER MUST BE PUMPED BACK ONTO THE SITE AND CANNOT DISCHARGE TO SYSTEMS TRIBUTARY TO SURFACE WATERS. 3.4, ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. T• IF VEHICLES ARE ENTERING OR EXITING THE SITES AT FOINTS OTHI-Ft THAN THECONST RUC TION F N rRANCE(S), FENCING SYULLL BE INSTALLED TO CONTROL TRAFFIC. UNLESS OT HERWME NOTED, DRAWING IS NOT TO SCALE (NISI STD. PLAN - 215.10 URIPUBLIC WORKS m7Puov11 DEPARTMENT STABILIZED CONSTRUCTION ENTRANCE GAZ 9/29/2018 1 I� R-425304 IN COMPLIANCE WITH CITY OF RENTON STANDARDS W DEVELOPMENT ENGINEERING SAMorman 04/20/2023 Z 0 OC LL OC LL in DATE: 03/16/2023 VARMA SFR FRONTAGE IMPROVEMENTS oOK: PAGE: N/ PAGE: A CONSTRUCTION DETAILS DRAWING NO: SHEET, OF, 4 5 r�1 L_J B21000376 M N O 0 W F- i i Know what's below. Call before you dig. 0 SSMH 0 RIM=535.90 IE 8" PVC (N)=522.80 IE 8" PVC (S)=522.80I CB 11 TYPE W/SOLID LID1 RIM = 534.77 a IE 12" = 531.75 0 10' AC DRIVEWAY APPROACH o CONNECT TO EX. SS PER COR STD = 406.1 0 IE = 522.Ot CONTRACTOR TO VERIFY INVERT = 0 INSTALL 1" WATER SERVICE PER KCWD 90 STANDARDS, 0 WATER IS PROVIDED BY KCWD90, INSTALLATION OF SERVICE IS PERMITTED BY THE DISTRICT 0 NOTE A FRANCHISE PERMIT WILL BE REQUIRED FOR KCWD90 TO WORK IN THE ROW. 0 THE CITY WILL PREPARE THE PERMIT TO BE ISSUED IN CONJUCTION WITHT HE CIVIL TAX PARCELPERMIT. 0 142305-9071 VACANT KING COUNTY PARKS RENTON ZONING R-4 a 0 0 T ❑ 0 a 0 0 0 I I REMOVE I E 12" PVC 0 CULVERT =527.96 TAX PARCEL 142305-9116 = 15514 SE 132ND ST, RENTON 98059 0 RENTON ZONING R-4 REMOVE IE 12" PVC 0 CULVERT =527.91 T REMOVEIE 12" CONC. CULVERT = =527.47 REPLACE IE 12" CONC. CULVERT ---Z- =527.06 I 0 1700 NW GILMAN BLVD, STE 200 IVIL ISSAQUAH, WA 98027 PHONE: (425) 821-5038 0 VARMA SFR FRONTAGE IMPROVEMENTS NW 1/4 OF NE 1/4 OF SECTION 14, T. 23 N., R. 05 E., W.M. CITY OF RENTON, KING COUNTY WASHINGTON rg LF 12" PVC @ 0.59 � � o B 112 TYPE 1 I 535.30 EX W/VANED GRATE RIM = 534.60 N IE 12" = 531.71 (S) ss; SS--Iss°° IE 12"=531.71 (W) I RESTORE FOGLINE TO ORIGINAL I a I LOCATION 3 v 534.39 I Im \ Ia.I. I I II I . I o I• o N Q) N LU CO J II W I Q Q �.I � I h o N I\S3 I 0 WO ;I �0 N I I I aI N I I N 'I SS P 5 .56 _ - - - - - L GRAPHIC SCALE - - - - -------------------- 20 0 10 20 a a - SCALE: 1" = 20' .4t 1 TIE TO SSCO L PROVIDED UNDER STREET IMPROVEMENTS 3 I PERMIT 47 LF 12" RCP 0 3.07. a - I� I� - J 'INSTALL DOUBLE ARROW NO PARKING ANY TIME' SIGN PER COR G138'(PYPq- B #3 TYPE 1 W/VANED GRATE RIM = 530.10 s I IE 12" = 527.30 EXTEND EX SS STUB AND PLACE NEW SSCO PER GO COR 406.1 530.46 6' ASPHALT RAMP 530.38 ALL WORK TO BE DONE WITHIN THE PARCEL TO BE REVIEWED UNDER SEPARATE BUILDING PERMIT EXCEPT AS NOTED. RELOCATE EX. POWER TRANSFORMER TO THIS LOCATION. A FRANCHISE PERMIT IS REQUIRED FOR PSE TO PERFORM WORK WIHTIN THE ROW. PSE SHALL ACQUIRE THE PERMIT AFTER CIVIL AND BUILDING PERMIT ISSUANCE. A PRIVATE UTILITY EASEMENT IS REQUIRED. SEE LANDSCAPE PLAN BY OTHERS FOR PROPOSED STREET TREE INFORMATION 0 530.10 + I RELOCATE EX. HYDRANT OUTSIDE OF PROP. PAVEMENT PER COR 529.93 STD 310.1. / I o WATER IS PROVIDED BY KCWD90, \ 3 ADJUSTMENT OF WATER UTILITY IS I 47 LF 12" PERMITTED BY THE DISTRICT 29.21 I I CONC 0 0.579 0 12" IE=52706t 3 �I N 3 � G G G G 03116120231 NO. REVISION 540 535 530 525 520 m N Ln w . . . . . . . . CB #1 TYPE . . . . . . . . . . . W/SOLID LID . . . . . . . . STA. 12+66.19, 12.0'R . . . . . . . . . . . .. ..... ...... .. =...7 M7. .... .... ...... ...... EXISTING .� . . . . . . . . . . . . . . . . . IE 12" . 5. . . . . . . . . . . . . GRADE . _ -. - -. - . . . 0%. . . . . . . . r . LF:12 0 3. . . . EXISTING 1 _ - 1 CULVERT T 47 LF 12': 0 0.50% . . . . LF 12". PVC ® 2.0X - -. STA:12 43:58, 20.7' . . . . . . . . . . . . . . PROP 1." .HATER . SERVICE. . . . . . . . . . . . . . . . . . . . . . . . . . . APPROX. LOCATION OUTLET STA.11+21.02, 2 i .7R B #2 TIP n 2; 48 IE=52706t ST .11 +10.22; 19.2' B : #3 TYPE. 1: EX. 6" SS STUB TA:12+53.95, 20.7' W/VANED GRATE STA: 12+6 i9; 20.7R EX.. 6." FH. LINE . W VANED GRATE / APPROX. LOCATION P bP. 6". SEWERS B. RIM = 534.50 APPROX.. LOCATION STA. :11+19.33, .7R . . APPROX. LOCA ON . .IE 12" = 528.06 (S) . . . . . . . . . . RIM = 530.10. . . .I . 12" =53 .57 (W) . . . . . . . . . . . . . IE 12" = 52733 . . . . . . . . . . . N N^ Ln N O N � O *O LO 00 of rn N of rn N X of O N � O �� LO O t N � �j N N cy L raj V- � V -t e} M � tri �rj u> 'n u� � W W W W ,may W U- W - W L- W 2 W - W W U W U W 11PA207ili DESIGNED: EDM DRAWN: TLK CHECKED: EDM DATE APPR APPROVED: NEM SCALE: 1 "=20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 11 +00 12+00 156TH AVE SE PROFILE 1 "=20 HORIZ, 1 "=5' VERT. 540 535 530 525 520 13+00 EX EX 30' ROW EX 30' ROW ' ' 5.5' DEDICATION 22' 8' LANDSCAPE EX PAVEMENT I 0.5' VERTICAL CURB 5' SIDEWALK EX 17'f PAVING L Al O TOM N O a J SAWCUT AND MATCFI EX EDGE OF PAVEMENT CURB PER COR SIDEWALK PER COR STD PLAN 101 STD PLAN 102 Z 156TH AVE SE SECTION W N TS G LU 0 LPL F-S-425302 R-425303 IN COMPLIANCE WITH CITY OF RENTON STANDARDS W 0 CURRENT PLANNING �' DEVELOPMENT ENGINEERING ff % < AWeihs 04/20/2023 I SAMorman 04/20/2023 ' Z � O LL DATE: LL VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 CITY OF 03/16/2023 RENTON VARMA SFR FRONTAGE IMPROVEMENTS FIELDBOOK: N/A a PAGE. DATUM � DRAWING No: Planning/Building/Public Works Dept. FRONTAGE IMPROVEMENT PLAN SHEET:OF: 3 B21000376 M N 0 W F_ 5" MAX. DRAINAGE GRATE TRIM s GRATE FRAME °o ea SEDIMENT AND DEBRIS a OVERFLOW BYPASS BELOW INLET GRATE DEVICE o FILTERED WATER 0 0 D D o D SECTION VIEW DRAINAGE GRATE IN - RECTANGULAR GRATE SHOWN RETRIEVAL SYSTEM (TVP.) o BELOW INLET GRATE OVERFLOW BYPASS (TVP.) ISOMETRIC VIEW NOTES 1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it will service. 2. The BIGD shall have a built-in high -flow relief system (overflow bypass). 3. The retrieval system must allow removal of the BIGD without spilling the collected material. 4. Perform maintenance in accordance with Standard Specification 8-01.3(15). PUBLIC WORKS CATCH BASIN FILTER STD. PLAN - 216.30 DEPARTMENT MARCH 2O08 �N,tp Know what's below. Call before you dig. USE CURRENT COR STD. PLAN DATED 9.28.20 1 8 1700 NW GILMAN BLVD, STE 200 IVIL ISSAQUAH, WA 98027 PHONE: (425) 821-5038 0311612023 I N 0. VARMA SFR FRONTAGE IMPROVEMENTS NW 1/4 OF NE 1/4 OF SECTION 14, T. 23 N., R. 05 E., W.M. CITY OF RENTON, KING COUNTY WASHINGTON ( a 0 0 a 0 SSMH 0 RIM=535.90 IE 8" PVC (N)=522.80 IE 8" PVC (S)=522.80 rl 0 aO 0 I a 0 I 0 0 0 I SAWCUT EX AC 0 MIN 1' FROM I -11I0I49i1a PAVEMENT I 2 O TAX PARCEL CL 142305-9071 0 VACANT KING COUNTY PARKS RENTON ZONING R-4 a 0 0 T EX UTILITY POLE (TYP) 0 a 0 TAX PARCEL 142305-9116 15514 SE 132ND ST, RENTON 98059 RENTON ZONING R-4 REVISION 0 a 0 0 1 0 II N ; N I/ v \ \ cd I v TAX PARCEL 366450-0181 13008 156TH AVE SE RENTON 98059 INSTALL STORM DRAIN I PROTECTION IN CATCH " BASINS PER COR SID 216.30 N ss0o (�) IS ss ss o ,r CONSTRUCTION ENTRANCE PER COR STD 215, SEE SHEET 5 80Z N 50100 I � — 1= G 1 % GRAVEL CONTRACTOR a PARKING AND MATERIAL LAY DOWN AREA; � W COVER w/PLASTIC AS NEEDED -� 1 IIII _ d,._. ,____i6m___� �" III II EX TREES TO BE REMOVED \ FOR INSTALLATION I; I / I OF IMPROVEMENTS )IN THE RIGHT OF 16 I /WAY s4. I III I I \ AREAS OF III _ R EXPOSED SOILS -7TO BE COVERED \ WITH STRAW N N III II \ �l MULCH IF NOT BEING WORKED I. — J LIMITS OF CLEARING ' & GRADING N I h�ti If �s3 I I , s 1 PROPOSED L01TREES y I I EX. TREE TO 1 REMAIN -CANOPY IFROM ARBORIST I I I..11 1 (TYP) o SS # I S�° �1 V) \ �� N i (I\1 i \s30� 90 N 00 TREE PROTECTION FENCING (TIP) V) I �I N I I CR G GI G G G G 3 IC. N t I l 0 5 10 20 SCALE 1 " = 20' ROADSIDE 32" F 24" MIN TYPICAL EXCAVATED FINAL GRADE POWER, GAS, AND COMMUNICATIONS 4• DIRT PILE 24" MIN BACKFILL (NO ROCKS OVER 10" DIAMETER) 36" MIN SEPARATION ' COVER 48„ 12" MIN 12" MIN MAX SEPARATION SEPARATION 6" OR 12" MIN SAND SHADING AFTER COMPACTION 2 SAND BEDDING GAS -1 L PRIMARY POWER COMMUNICATIONS J CABLES OR CONDUIT JOINT UTILITY TRENCH SCALE: 1"-20' HORIZONTAL DESIGHORIZONTALNAD 1983/1991 CITY OF EDM '3 DRAWN. TLK RENTON ONE INCH DATU M CHECKED: AT FULL scaLE Planning/Building/Public Works Dept. EDM IF NOT ONE INCH BY DATE APPR APPROVED: NEM SCALE ACCORDINGLY CONSTRUCTION SEQUENCE A. CONDUCT PRE -CONSTRUCTION MEETING. B. FLAG OR FENCE CLEARING LIMITS. C. POST SIGN WITH NAME AND PHONE NUMBER OF TESC SUPERVISOR. D. INSTALL CATCH BASIN PROTECTION IF REQUIRED. E. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S). F. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.). G. CONSTRUCT SEDIMENT PONDS AND TRAPS (IF NEEDED) NOT ANTICIPATED. H. GRADE AND STABILIZE CONSTRUCTION ROADS. I. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY WITH CLEARING AND GRADING FOR PROJECT DEVELOPMENT. J. MAINTAIN EROSION CONTROL MEASURE IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND MANUFACTURER'S RECOMMENDATIONS. K. RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE, THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY TESC MINIMUM REQUIREMENTS. L. COVER ALL AREAS WITHIN THE SPECIFIED TIME FRAME WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING, CRUSHED ROCK OR EQUIVALENT. M. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN 7 DAYS. N. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. 0. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BEST MANAGEMENT PRACTICES REMOVED IF APPROPRIATE. EROSION PROTECTION NOTE ALL EXPOSED SOIL TO BE COVERED WITH MULCH, STRAW, AND/OR PLASTIC SHEETING PER FIG. C.3.4.A AND/OR TABLE C.3.2.A KCSWDM. UNDER NO CIRCUMSTANCES SHALL SOIL STOCKPILES BE LEFT UNCOVERED. SOIL AMENDMENT NOTE TO THE MAXIMUM EXTENT POSSIBLE, TOPSOIL/FUTURE LANDSCAPE AREAS OUTSIDE IMPERVIOUS AREAS SHALL BE LEFT UNDISTURBED AND PROTECTED FROM COMPACTION DURING CONSTRUCTION. THIS APPLIES SOIL AMENDMENT OPTION 1 PER KING COUNTY POST CONSTRUCTION STANDARD REQUIREMENTS. SEE APPROVED COMPOST AND TOPSOIL CALCULATION WORKSHEET. A. LEAVE NATIVE SOIL UNDISTURBED (965,263 SF) B. STOCKPILE NATIVE SOILS AND REAPPLY AFTER GRADING AND CONSTRUTION (28,314 SF) SILT FENCE MAINTENANCE PER 2016 KCSWDM 1. ANY DAMAGE SHALL BE REPAIRED IMMEDIATELY. 2. IF CONCENTRATED FLOWS ARE EVIDENT UPHILL OF THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TOT HE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVE THE TRAPPED SEDIMENT. 4. SEDIMENT MUST BE REMOVED WHEN THE SEDIMENT IS 6 INCHES HIGH. 5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED. EXISTING UTILITY NOTE ALL UTILITIES MUST BE UNDERGROUND TO THE PROPERTY. AND THE OWNER OR CONTRACTOR WILL NEED TO CONTACT ALL UTILITY COMPANIES PRIOR TO NEEDING ANY OF THESE SERVICES. EACH COMPANY WILL NEED TO DESIGN THEIR CONNECTION AND APPLY TO THE CITY FOR A PERMIT PUGET SOUND ENERGY CARLI BUNKELMAN 425-429-0227 CARLI. BUNKELMAN@PSE. COM LUMEN/CENTURY LINK AMY ALLISTON 253-797-4545 AMY. ALLISTON@LUMEN. COM LUMEN/CENTURY LINK EDD SAGGUS 720-936-9259 ESAGGUS®TRUENETCOMMUNI CA TIONS. COM COMCAST MICHELE MOORE 206-388-4316 MICHELE. MOORE@PRINCETELECOM. COM ZIPLY JAY SCHWAB 425-263-4019 JAY.SCHWAB@ZIPLY .COM Al C) 0 N a D J U) H Z W W O�/ W a. R-425302 2 IN COMPLIANCE WITH CITY OF RENTON STANDARDS LU CD CURRENT PLANNING DEVELOPMENT ENGINEERING < AWeihs 04/20/2023 SAMorman 04/20/2023 ' Z NO LPL LL W DATE: LL 03/16/2023 in VARMA SFR FRONTAGE IMPROVEMENTS FIELDBOOK: N/A PAGE: DRAWING N0: TESC/TREE RETENTION PLAN SHEET, OF, 2 5 B21000376