Loading...
HomeMy WebLinkAboutR-423837A PORTION OF THE NW 1/4 OF SECTION 8, TOWNSHIP 23N, RANGE 5E, W.M. 00 co N CD I 0 W rr W I— Z w U 0 Z Z Q 06 C/) rr W I- iCc D 0 W U H v / �/ rr w 0 Z 0 C/) W I— Q w 7 1 PROPOSED LAYOUT: NORTH SYSTEM 1,666 STORMTECH MC-3500 CHAMBERS 68 STORMTECH MC-3500 END CAPS 12 STONE ABOVE (in) 9 STONE BELOW (in) 40 % STONE VOID 292,010 INSTALLED SYSTEM VOLUME (CF) BETWEEN ELEVATION 20.0 & 14.7 (PERIMETER STONE INCLUDED) 85578 SYSTEM AREA (ft2) 1196 SYSTEM PERIMETER (ft) PROPOSED ELEVATIONS: NORTH SYSTEM 27.00 MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED) 21.00 MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC) 20.50 MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC) 20.50 MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT) 20.50 MINIMUM ALLOWABLE GRADE (TOP OF RIGID PAVEMENT) 20.00 TOP OF STONE 19.00 TOP OF MC-3500 CHAMBER 17.17 24" TOP MANIFOLD INVERT 15.42 24" ISOLATOR ROW PLUS CONNECTION INVERT 15.25 BOTTOM OF MC-3500 CHAMBER 14.50 BOTTOM OF STONE PROPOSED LAYOUT: COMBINED 3,332 STORMTECH MC-3500 CHAMBERS 136 STORMTECH MC-3500 END CAPS 12 STONE ABOVE (in) 9 STONE BELOW (in) 40 % STONE VOID 584,020 INSTALLED SYSTEM VOLUME (CF) BETWEEN ELEVATION 20.0 & 14.7 (PERIMETER STONE INCLUDED) 171156 SYSTEM AREA (ft2) 2,392 SYSTEM PERIMETER (ft) NOTFS • MANIFOLD SIZE TO BE DETERMINED BY SITE DESIGN ENGINEER. SEE TECHNICAL NOTE 6.32 FOR MANIFOLD SIZING GUIDANCE. • DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAY BE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE TO STANDARD MANIFOLD COMPONENTS IN THE FIELD. • THIS CHAMBER SYSTEM WAS DESIGNED WITHOUT SITE -SPECIFIC INFORMATION ON SOIL CONDITIONS OR BEARING CAPACITY. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR DETERMINING THE SUITABILITY OF THE SOIL AND PROVIDING THE BEARING CAPACITY OF THE INSITU SOILS. THE BASE STONE DEPTH MAY BE INCREASED OR DECREASED ONCE THIS INFORMATION IS PROVIDED. • NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE PROPOSED I (DESIGN BY ENGINEE INSTALL f 24" PARTIAL CUT END CAP, PART# MC35001EPF TYP OF ALL MC-3500 24" BOTTOM CONNECTIONS) ALL STRUCTURE CONNECTIONS TO MATCH ENGINEERED DESIGN INTENT AND LOCATION PER C3.07 G E N w� 33708 R A E CISTV, �1 %NAL �� T 0 R 01/T� �/ STUDIO = ROPOSED STRUCTUF (DESIGN BY I 24" X 24" ADS N-12 TOP MANIFOLD INVERT 23.05" ABOVE CHAMBER BASE (SEE NOTES) COUGHLINPORTERLUNDEEN STRUCTURAL CIVIL SEISMIC ENGINEERING 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 (206) 343-0460 www.cplinc.com NO. REVISION 0 (fl M FEND CAP PP24TC OR MC35001EPP24TW 3500 24" TOP CONNECTIONS r Lm\iL IVIIINIIVIUIVI I 1 .J I.JI /'1UJf LVJ I 1 J vvv V L1v kiEOTEXTILE OVER BEDDING STONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALL CHAMBER INLET ROWS i • m SURVEYED: WH PACIFIC DESIGNED: ML DRAWN: JAS CHECKED: WCA APPROVED: TBB SCALE: AS SHOWN ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY W p J w Z Q a o Of z 0 w Z 2 0 Q �3 Z > J Q 0 W W < > Q W z Q Z p Q o W w W X z if w cn U LL. U) LU z LLI LU Q 0 U Z D z Z 0 Z Oljj 0 LLJ � W J F_06 Q 0 W U7 =W. 0 X o z z Lu o U Of _ U o U O CN CV 0 c`.) a- ti CM O o cn 6i Q 0 In w m H Z) 0 O w > Q 0 J Z p 2 X W w w W H 0 cn O a o z O O z a W 0 0 a a_ a U W O d z 0 f- a U w 0 Q Z J w w w W z w H > > Q O a d m m Q� O W > p p W � 0 w Q w w F z w w w o w jx w Q m cn rl w w � W w U w � 0 W W W W IY � m Z (n U U D_ c K !Y W Q Y of J U U Of w C In 3: C7 O rL z 0 Uof COm F- F- 0 � w 0 0 0 o_ m o DeQ W J m N c'7 N N N N N (V N N N N N N N N N N w H JQ CD N 4 O m O O C7 O M (0 N � N N H Q O H D W N N O W w W 0 w O O O O O O wC/) ul J Z� CD w Z 0 w 0 zW O 0Q U w0 = 00 W CO U Lu co Q ~ O =Q �p s O wZ oQ zp E N LLI O ~U wa ate+ of w p wE U) O� U L Of 7 L N o° O E N cn D_ cn w � (� Q I U 00 0F o o� W p w � O U) 0 �O O O 0- LLI J O O L) CID cy) Q w Z 2w Q = Ir z o(D O w LLL L ? 0 o(D 0 W Q cno mI J CO — L0 0 U5 X W Q= I*- D- Ofo � 0- z� W J wm m_ U)� az =O c� � zw §(If W ` Q O �< 2 SHEET 8 OF R-423837 IN COMPLIANCE WITH CITY OF RENTON STANDARDS L ELOPMENT ENGINEERINGanders 05/10/2023 Cj) HORIZONTAL: N D 1983/1991 CITY OF SEATTLE SOUNDERS FC HEADQUARTERS RENTON & TRAINING CENTER DATUM RENTON, WASHINGTON Planning/Building/Public Works Dept. GRADING & DRAINAGE DETAILS 05/01/20 PAGE: C3.22 SHEET: OF: 36 71 LO O O N N 6 , u H N Q J IIr W Z W U Z Z Q 06 C/) IIr W Q C� 0 Q W U w Cf) i0C W 0 Z 0 Cn Lu I— W C)