Loading...
HomeMy WebLinkAboutR-4238695 1 4 1 3 1 2 0 C B A i i / o — — — — — — — — — 1— — 1 — El, — - - // 9 g 49.00' ( I 3" MAIN I I�c nn _ ____ _sox 4- (TYP.)�.—. TYP. \ �° 50.00' BALL VALVE �� �ME� _ I I ) ;I co Na 1 II I� ��l � —�I� — —� �� 3 Qcv-� 'III a / Z04E Zi BALL VALVE 1 • I I \ 5a��1 F231 QUI K �URLIN •I z / ASPHgo /A Q ILT / T ( —� I I Vl�LV oco N --- --------- I I I L OT LOCATE — \ I �Q / / / I / V ZON 17 s \ ) ---- 1 1 / W D S ON POLE 1 / --- 42=0 SE IN -PR UND 4� — .// i — REEL / / I 3"MAINLINE 1 _AK pm� MOLL I _ — — _ — MATCHLINE SEE SHEET F142 — — — — — — — — — — — — — FZONE 33 k I MATCH LINE SEE SHEET F142 �'�I ZON E z7 IRRIGATION LEGEND --• •-- SCH 40 PVC IRRIGATION MAIN LINE - SCH 40 PVC PIPE (LATERAL) I � POINT OF CONNECTION: TO INCLUDE RPBA (WALL sox sox MOUNT), STRAINER AND BOOSTER PUMP GATE VALVE AND BOX I BUILDING v THRUST BLOCK QUICK COUPLER VALVE .7' REMOTE CONTROL VALVE 360• OPPOSING NOZZLE ROTARY POP UP SPRINKLER, 70 PSI. 60' RADIUS, 16.6 GPM HUNTER 1-40-06-SS-ON-18 ADJUSTABLE ROTARY POP UP SPRINKLER, 70 PSI. 57' RADIUS, 16.6 GPM HUNTER 1-40-06-SS-15 .8 ADJUSTABLE ROTARY POP UP SPRINKLER, 70 PSI. 57' RADIUS, 16.6 GPM ® HUNTER 1-40-06-SS-15 ING IN -GROUND HOSE REEL 101 ® CAM -LOCK HOSE CONNECTION _ HUNTER ACC2 AUTOMATIC CONTROLLER AHV VAULT WITH QUICK COUPLING VALVE AND HEAD BIDDER DESIGNED TEMPORARY �® _ RESTORATION IRRIGATION, 100% BUILD COVERAGE. REFER TO IRRIGATION DETAILS. - 25—l' 59,752 ' — SN (1] RRIGATIOIV NOTES NOTE LEGEND 1. (INDICATES GENERAL CONSTRUCTION NOTE) T. (INDICATES SPECIFIC CONSTRUCTION KEYNOTE) 1. REFER TO CIVIL AND MECHANICAL PLANS FOR IRRIGATION SUPPLY. CONTRACTOR SHALL 9. CONTRACTOR SHALL LABEL REMOTE CONTROL VALVES IN SEQUENCE WITH STATION NUMBERS. VERIFY PRESSURE PRIOR TO BEGINNING WORK. CONTACT OWNER IMMEDIATELY SHOULD DISCREPANCY ARISE AND REDIRECT WORK TO AVOID DELAY. 10. CONTRACTOR SHALL REFER TO DETAILS AND SPECIFICATIONS FOR ADDITIONAL INFORMATION. 2. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE A MINIMUM OF 48 HOURS 11, FIELD LOCATE THE EXISTING IRRIGATION SUPPLY LINE AND CORRESPONDING CONTROL WIRES PRIOR TO START OF ANY IRRIGATION WORK. AT THE FIELD EDGE. CONFIRM LOCATION AND NUMBER OF CONTROL WIRES PRIOR TO INSTALLATION OF THE NEW IRRIGATION SYSTEM. 3. CONTROL WIRES SHALL BE 14 GAUGE (RED). SEPARATE WIRES SHALL RUN FROM THE CONTROLLER TO EACH VALVE. COMMON GROUND WIRES SHALL BE 12 GAUGE (WHITE). ALL 12. CONNECT TO EXISTING IRRIGATION CONTROL WIRE WITH APPROVED WATER -PROOF SPLICES IN CONTROL WIRES LEADING FROM VALVES TO CONTROLLER MUST BE LOOPED UP A MINIMUM BOX. SET SPLICE BOX FLUSH WITH FINISH GRADE ADJACENT TO THE FIELD EDGE. OF THREE FEET (3') INTO EVERY VALVE BOX INTERCEPTED ON THE WAY TO THE CONTROLLER. 13. PROVIDE CONCRETE THRUST BLOCKING AT ALL NEW IRRIGATION MAIN LINE TEES AND BENDS. 4. IRRIGATION SYSTEM DESIGN IS DIAGRAMMATIC. WHERE PIPING, VALVES, QUICK COUPLERS, 14. SET IRRIGATION REMOTE CONTROL VALVE VAULTS AND BOXES FLUSH WITH THE ADJACENT ETC. ARE SHOWN OUTSIDE PLANTING AREAS, OR LIMIT OF WORK; INTENT IS FOR PIPING, SURFACES. VAULTS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE FIELD EDGE. VALVES, ETC., TO BE INSTALLED WITHIN TURF OR PLAYABLE AREA. INDICATE EXACT LOCATIONS OF IRRIGATION EQUIPMENT ON RECORD DRAWING. 15. PART CIRCLE SPRINKLERS HEADS SHALL BE LOCATED 1 INCH MINIMUM AND 3 INCHES MAXIMUM FROM THE FIELD EDGE. 5. CONTRACTOR SHALL PROGRAM CONTROLLER TO INSURE PROPER IRRIGATION APPLICATION BASED ON PLANT TYPE, SLOPE, EXPOSURE, SOIL TYPE AND SEASON. 16. FURNISH AND INSTALL SPRINKLER HEAD AS REQUIRED TO WATER SETTLE ROOT ZONE SAND PRIOR TO SOD INSTALLATION. THE SPRINKLER HEADS SHALL BE INSTALLED 1 /2 INCH ABOVE 6. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETE AND EFFECTIVE COVERAGE OF ALL THE ROOT ZONE ELEVATION TO ALLOW FOR THE HEADS TO BE 1 /2 INCH BELOW THE FINISH PLANTED AREAS BY BALANCING EACH SYSTEM FOR OPTIMUM COVERAGE AND ADJUSTING EACH GRADE OF THE SOD (SOD DEPTH WILL BE 1 INCH). ARC, RADIUS AND NOZZLE TO ENSURE HEAD TO HEAD COVERAGE AS DIRECTED ON SITE BY OWNER'S REPRESENTATIVE. 17. ALIGNMENT OF FULL CIRCLE HEADS SHALL NOT VARY MORE THAN 3 INCHES. 7. CONTRACTOR SHALL ADJUST IRRIGATION HEADS FOR OPTIMUM COVERAGE WHILE REDUCING OVER SPRAY ONTO WALKWAYS AND ADJACENT STRUCTURES. VALVES SHALL BE ADJUSTED TO AVOID MISTING AS APPLICABLE. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO HEAD CURRENT PLANNING u JDing 05/10/2023 LOCATIONS IN FIELD AS NECESSARY ONLY WITH THE APPROVAL OF THE OWNERS REPRESENTATIVE. 8. CONTRACTOR TO PROVIDE A FULL SET OF NOZZLES FOR EACH ROTOR TO THE OWNER. 0 30' 60' NORTH SCALE:1"- 30' GENERATOR sTUD10 TENANT SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM OWNER / DEVELOPER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM ARCHITECT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM LANDSCAPE ENGINEER D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM STRUCTURAL & CIVIL ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 901 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM MEP ENGINEER HENDERSON ENGINEERS 8345 LENEXA DRIVE, #300 LENEXA, KS 66214 916.663.8700 HENDERSONENGINEERS.COM DEVELOPMENT ENGINEERING Wanders 05/10/2023 ul ARCHITECT: MICHAEL J. KRESS LICENSE NO. 12779 SEAL SEATTLE SOUNDERSFC HEADQUARTERS & TRAINING CENTER 1901 OAKESDALE AVENUE SW RENTON, WA 98057 FIELD CONSTRUCTION ISSUE DATE: 05.01.2023 REV DESCRIPTION DATE PROJECT NO. 21032 DRAWN BY: REF CHK'D BY: EJG SHEET TITLE IRRIGATION PLAN FIELD 1 & GK AREA R-423868 F 141 DA HOGAN 02VG1 ist NtRA10K SIUM LLC 4/4N225:40:59 PM