HomeMy WebLinkAboutR-4238795 4 3 2 00 I W U L 0 3" WASHWATER / QUICK COUPLER PIPING GATE VALVE #3 I 2" FLOW CONTROL SENSOR -MIN 36" M FROM MASTER VALVE 2" MASTER VALVE 4" PVC MAIN LINE BOOSTER PUMP ASSEMBLY, SEE MECHANICAL REDUCED PRESSURE BACKFLOW ASSEMBLY, SEE MECHANICAL 1 POINT OF CONNECTION -SCHEMATIC F230 NOT TO SCALE SURFACE VARIES MA 4" WATER SUPPLY AND IRRIGATION METERS, SEE CIVIL AS A CONDITION OF APPROVAL: THE MECHANICAL PLAN SUBMIT WITH THE BUILDING PERMIT APPLICATION SHALL PROVIDE PUMP SPECIFICATIONS TO DEMONSTRATE THAT THE PUMP FLOWRATE DOES NOT EXCEED THE MAXIMUM CONINUOUS FLOWRATE OF THE WATER METER (800 GPM FOR THE 4" SENSUS OMNI C2) AS A CONDITION OF APPROVAL: A MECHANICAL AND/OR PLUMBING PLAN SHALL BE INCLUDED WITH THE BUILDING PERMIT APPLICATION THAT DEMONSTRATES AN ADEQUATELY SIZED DRAIN IS PROVIDED FOR THE RPBA RELIEF VALVE. IN. 36" - FLUSH 12" ROUND PLASTIC VALVE BOX 3 2 I I 1 I � ----- � --- FLOW I � NOTES: O SET ALL PLASTIC VALVE BOXES ON PRECAST MASTER VALVE (-A CONCRETE BRICK ON FIRM SUBGRADE, BRICK O2 FLOW SENSOR TO BE MIN. (4) 4"x4"x8" 3O PROVIDE COMMUNICATION 50 PROVIDE NON -WOVEN 40Z. GEOTEXTILE AND 9" CABLE AND VOLTAGE WIRE MIN. DEPTH OF PEA GRAVEL BELOW ALL VALVES, 14 GAUGE, ALLOW A 24" COIL TYPICAL. AT EACH SPLICE. © STACK APPROVED PLASTIC VALVE BOXES TO INSURE VERTICAL CLEARANCE FOR MAINTENANCE; OVERLAP BOXES AT HALF OR MORE. 2 1 MASTER VALVE &FLOW SENSOR F230 NOT TO SCALE WALL MOUNTED VANDAL -RESISTANT BUILDING WALL CONTROLLER ASSEMBLY CONTROLER J CABINET w QLu TERMINAL BLOCK o w w �I-QLd 0 = z O Z~�Q 00 H N J F Z O O Q:� CD J Cn 142" CONDUIT TO POWER SOURCE INSTALL 5 AMP CIRCUIT A BREAKER IN ELECTRICAL SOURCE PANEL ° a a a 1 a a ° a a ° d a � �— VALVE SOLENOIDS DECODER FLOW 2 CONTROL �3O SENSOR I�VIVIIVIVIV LIVLI\VILIIVV VVII\L (IN PARALLEL) 4 IRRIGATION CONTROLLER SCHEMATIC F230 NOT TO SCALE MIN. 12" WIDE TRENCH (OR AS REQUIRED TO ALLOW ADEQUATE COMPACTION OF BACKFILL) FINISH GRADE 24" MIN. SPECIFIED SOD SPECIFIED TOPSOIL DUAL 48M DECODER OUTPUT MODULE #14 OF 24V ENERGIZING WIRE NEW PAVEMENT OR EXISTING PAVEMENT PATCH PER SPR STD. PLANS & SPECS (TYP.) 4 III• III II III � =11 000°000� Oo�o�O� Typ c DETECT -A -TAPE (BLUE) 6"ABOVE PIPE. n� CLEAN, COMPACTED, SUITABLE 12" MIN. COVER IMAN Ikvi--1_Tel391aa SCH 40 PVC MAIN LINE. BUNDLE CONTROLLER WIRES UNDER MAIN LINE ON OPPOSITE SIDE FROM SWING JOINTS (WHEN LATERAL & II II. O �j lI MAIN SHARE THE SAME IIII - II, TRENCH). NOTE: TAPE WIRES PER SPEC. BUT DO NOT TAPE BUNDLED WIRES TO MAIN LINE. MAIN LINE TRENCH Em 6" TYP 12" MIN. COVER 4" MIN. IRRIGATION SLEEVE TRENCHING UNDER SURFACE ABOVE VARIES 4" MIN. SIDEWALK \j \ o COMMON (IN PARALLEL) NOTES: 1. EXTEND 2 SPARE WIRES TO EACH VALVE MANIFOLD. LABEL EACH CONTROL WIRE WITH CONTROLLER STATION DESIGNATION. 2. USE SEPARATE COLORED JACKETED DECODER WIRE WIRE FOR EACH INDIVIDUAL VAULT LOCATION 2.1. NORTH -BLUE 2.2. WEST -RED 2.3. EAST -WHITE FINISH GRADE AWCUT EXISTING AVEMENT (THICKNESS TYP.) II III - DETECT —A —TAPE (BLUE & RED) SHALL BE 6" BELOW TOP OF TRENCH GRADE OVER EACH PIPE OR CONDUIT (TYP.) ALL BACKFILL SHALL BE MINERAL AGGREGATE TYPE 2 (1—Y4" MINUS CR) SCH.40 PVC SLEEVE WITH MAIN OR LATERAL LINES & CONTROL WIRES IN SEPARATE CONDUIT &/OR SLEEVE (TYP.) NOTES: 1. SLEEVE ID SIZE SHALL BE AT LEAST 2 TIMES GREATER THAN OD SIZE OF THE PIPE. 2. WIRES SHALL BE IN SEPERATE CONDUIT SLEEVE EXCEPT UNDER ROADS WITH HEAVY VEHICLE TRAFFIC. 3. SLEEVES SHALL BE REQUIRED UNDER ALL PAVED AREAS & WALL OR FOOTING PENETRATIONS. FINISH GRADE DETECT —A —TAPE (BLUE & RED) SHALL BE 6" BELOW TOP OF TRENCH GRADE OVER EACH PIPE OR CONDUIT (TYP.) SELECT NATIVE BACKFILL SCH.40 PVC SLEEVE WITH MAIN OR LATERAL LINES & CONTROL WIRES IN SEPARATE CONDUIT &/OR SLEEVE (TYP.) NOTES: 1. SLEEVE ID SIZE SHALL BE AT LEAST 2 TIMES GREATER THAN OD SIZE OF THE PIPE. 2. WIRES SHALL BE IN SEPARATE CONDUIT SLEEVE. /\ 3. SLEEVES SHALL BE REQUIRED UNDER ALL PAVED AREAS, CURBS, AND SYNTHETIC TURF, AND WHERE SPECIFICALLY SHOWN. 4. ALLOW FOR FLANGE SIZE ON ALL SLEEVES CARRYING HDPE PIPE. GENERATOR STUDIO TENANT SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM OWNER 1 DEVELOPER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM ARCHITECT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM LANDSCAPE ENGINEER D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM STRUCTURAL & CIVIL ENGINEER COUGHLIN PORTER LUNDEEN (CPQ 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM MEP ENGINEER HENDERSON ENGINEERS 8345 LENEXA DRIVE, #300 LENEXA, KS 66214 816.663.8700 HENDERSONENGINEERS.COM DEVELOPMENT ENGINEERING NJanders 05/10/2023 ARCHITECT: MICHAEL J. KRESS LICENSE NO. 12779 SEAL SEATTLE SOUNDERSFC HEADQUARTERS & TRAINING CENTER 1901 OAKESDALE AVENUE SW RENTON, WA 98057 FIELD CONSTRUCTION ISSUE DATE: 05.01.2023 REV DESCRIPTION DATE PROJECT NO. 21032 DRAWN BY: REF CHK'D BY: EJG SHEET TITLE IRRIGATION & WASHWATER DETAILS R-423878 DA HOGAN © 2022 GENERATOR STUDIO LLC 41412022 5:40:59 PM 3 IRRIGATION CONTROLLER -CABINET F230 NOT TO SCALE 2"CONDUIT FOR FIELD WIRES 5 TRENCHING FOR MAINLINE &LATERAL PIPE F230 NOT TO SCALE