Loading...
HomeMy WebLinkAboutR-4238845 4 3 2 GENERATOR STUDIO u VARIANCE FOR FENCE HEIGHT TO BE SUBMITTED AT A LATER DATE. C 0 A 25HT. END POST AND LINE POST SIZE PER SCHEDULE 15' HT. NETTING 10' HT. CHAINLINK FENCING MAX 160LF CABLE NETTING POSTS @ 20'-0" OR 30' 0" O.C. _ 1 /2 ON -CENTER DISTANCE (18" MAX NET CABLE SAG) SEE TOP CORNER CABLE & RIGGING INSET 0 SEE TOP EDGE SUPPORT INSETO2 CONNECTION NOTES: EE INTERMEDIATE NET UPPORT INSET. INSTALL @ ' O.C. VERTICAL SEE VERTICAL CABLE RIGGING INSET KNOTLESS 1.75" SQ. NYLON BALL CONTROL NETTING 1 12"MIN, 18"MAX SAG AT CENTER OF CABLE KNOTLESS 1.75" SQ. NYLON BALL CONTROL NETTING 10 TOP CORNER; EYE BOLT SIZED TO ACCOMMODATE BOTH THE LIMIT ON GAP BETWEEN THE POLE AND THE VERTICAL CABLE AND THE CONNECTING LINKS FOR BOTH THE VERTICAL AND HORIZONTAL SUPPORT CABLES. PROVIDE (1) TURNBUCKLE AT EACH END OF EACH CABLE. 2� TOP EDGE OF BALL CONTROL NET ASSEMBLY HELD TO THE SUPPORT CABLE WITH GALVANIZED OR STAINLESS STEEL OR ALUMINUM THREADED LINK, SNAP LINK, OR CARABINER-TYPE CONNECTOR WITH APPROVED BLACK FINISH. SIZE TO ALLOW SPACING NO LESS THAN 12" O.C. BUT NO GREATER THAN 21 " O.C. TO REDUCE ROPE BORDER SAG BETWEEN CONNECTIONS. 30 LOOSE VERTICAL CONNECTIONS TO BE VIA BLACK VINYL OR POLYESTER SNAP -CLIP SPACED 12"-15" O.C. ® BOTTOM VERTICAL SUPPORT CABLE CONNECTION TO INCLUDE A TURNBUCKLE FOR ADJUSTMENT. O5 BALL CONTROL NET ASSEMBLY BOTTOM EDGE CONNECTION TO BE VIA HEAVY DUTY, UV -RESISTANT, NYLON ZIP TIE 12"-15" O.C. DIRECTLY TO CHAIN LINK FABRIC BELOW THE TOP RAIL. CLF FABRIC TO BE INSTALLED ON THE FIELD SIDE OF THE FRAMEWORK. BALL CONTROL NET TO BE SECURED TO THE FIELD SIDE OF THE FINISHED CHAIN LINK FENCE ASSEMBLY BELOW THE TOP RAIL. © MAIN VERTICAL SUPPORT CABLE CONNECTION TO POLE AT 12' - 15' O.C., MATCH TOP TAB OR FLANGE A 1 1 BALL CONTROL & CABLE -FENCING & NETTING DETAIL F241 % NOT TO SCALE B TOP CORNER CABLE & RIGGING NOT TO SCALE I (INCLUDE 1 TURNBUCKEL MIN., 2 FOR SPANS EXCEEDING 30') �r.1 TOP EDGE SUPPORT x HARDWARE NOTES: NOT TO SCALE VERTICAL EDGE SUPPORT NOT TO SCALE OA EYE BOLT LOCATED NEAR TOP OF POLE ASSEMBLY. PLACEMENT TO ACCOUNT FOR POTENTIAL OF UP TO 18" OF SAG IN THE TOP SUPPORT CABLE AT 70LBF TENSION WITH THE NETTING IN PLACE. MAX SPACING BETWEEN HORIZONTAL CABLE ENDS 120LF < GALVANIZED OR STAINLESS STEEL THREADED MASTER LINK CARABINER OR APPROVED EQUAL, 1 /2" x1-1.5" PROVIDE HORIZONTAL HARDWARE WITH APPROVED BLACK FINISH. CO GALVANIZED STEEL THIMBLE SIZED FOR THE SPECIFIED WIRE ROPE; USE AT ALL CABLE TERMINATIONS. OD GALVANIZED STEEL WIRE ROPE, 5/16" 0. OE WIRE ROPE CONNECTOR, U-BOLT TYPE. MIN. TWO PER CONNECTION OR AS NEEDED. OF VINYL TAPE TRIPLE WRAP ALL CUT WIRE ENDS. OG PRE -FABRICATED BALL CONTROL NET ASSEMBLY TO BE PROVIDED WITH A CONTINUOUS 5/8 "0 NYLON ROPE BORDER. HO BLACK VINYL OR POLYESTER SNAP -CLIP FOR VERTICAL CABLE -TO -ROPE CONNECTIONS ONLY < GALVANIZED OR STAINLESS STEEL TURNBUCKLE, 1 /2 " x 12". VERTICAL CABLE RIGGING NOT TO SCALE �C1 CONNECTION @CHAIN LINK FENCE NOT TO SCALE INTERMEDIATE NET SUPPORT NOT TO SCALE TENANT SEATTLE SOUNDERS FC 159 S. JACKSON STREET, #200 SEATTLE, WA 98104 SOUNDERSFC.COM OWNER I DEVELOPER UNICO PROPERTIES LLC 1215 FOURTH AVENUE, SUITE 600 SEATTLE, WA 98161 UNICOPROP.COM ARCHITECT GENERATOR STUDIO LLC 1615 BALTIMORE AVE KANSAS CITY, MO 64108 816.333.6527 GENERATORSTUDIO.COM LANDSCAPE ENGINEER D.A. HOGAN & ASSOCIATES, INC. 1450 114TH AVE SE, SUITE 225 BELLEVUE, WA 98004 206.285.0400 DAHOGAN.COM STRUCTURAL & CIVIL ENGINEER COUGHLIN PORTER LUNDEEN (CPL) 801 SECOND AVENUE, SUITE 900 SEATTLE, WA 98104 206.343.0460 CPLINC.COM MEP ENGINEER HENDERSON ENGINEERS 8345 LENEXA DRIVE, #300 LENEXA, KS 66214 816.663.8700 HENDERSONENGINEERS.COM ARCHITECT: MICHAEL J. KRESS LICENSE NO. 12779 SEAL SEATTLE SOUNDERSFC HEADQUARTERS & TRAINING CENTER 1901 OAKESDALE AVENUE SW RENTON, WA 98057 FIELD CONSTRUCTION ISSUE DATE: 05.01.2023 REV DESCRIPTION DATE PROJECT NO. 21032 DRAWN BY: REF CHK'D BY: EJG SHEET TITLE NETTING DETAILS rDA HOGAN F241 © 2022 GENERATOR STUDIO LLC 41412022 5:40:59 PM