HomeMy WebLinkAboutR-392223V I W PIPE ALLOWANCES MAXIMUM PIPS MATERIAL INSIDE DIAMSTSR REINFORCED OR 12" PLAIN CONCRETE ALL METAL PIPE 16' CPSSP* 12' (STD. SPEC. 9-05.20) SOLID WALL PVC 16° (STD. SPEC. MS.12(1)) PROFILE WALL PVC 16' (STD, SPEC. 9416.12(2)) I i PIPE 0, 0. �. 1' - 0 1' - 0 MIN MIN I END CAP OR PLUG FLOW TO SECOND CLEAN OUT WYE FROM DISPERSAL TRENCH PIPE „ IF NECESSARY r M1N 6 PERFORATED I NOTCHED PIPE LAID FLAT LEVEL GRADE BOARD TYPE I CB WI SOLID COVER 2" X 2" NOTCHES + ' 18" O.C. A (LO CKING) TYPE ! CB W/SOLID COVER 25150' M SW 1/4 SECTION 29, TOWNSHIP 23 N RANGE 5 E, W.M. _ A VAM RIDGE NOTE., ALL THROUGH CURB INLETS MUST HAVE BI-DIRECTIONTAL r.RA TFC' CATCH BASIN FRAME AND VANED ORATE (DETAIL 204,00) HANDHOLD 3 RECTANOULAR ADJUSTMENT SECTION OR CIRCULAR ADJUSTMENT SECTION v GROUT, TYPICAL (SEE NOTE 5) FLATSLABTOP �! o xr a• ao• tr,a4•ottea• a MORTAR (TYP.) STEPS OR LADDER �o FILLET `a � � 't�! `\ N RErRFORpNO e7EFi (rYP.) - GRAVEL ty , BACMLL FOR D'E Za I PNESWUNGBgOpNO ail SEPARATE BASE INTEGRALSABE CAST -IN -PLACE PRECAST WITH RISER - - +r • .i.. DRAWL BACKRLL FOR M= PIPE TARE a -- SEPARATE BASE PRECAST CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER WALL THICKNESS BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS - BASE REINFORCING STEEL, tn'Irt. IN EACH DIRECTION SEPARATE BASE INTEGRAL BASE 48' 4' 1' 36' 8' 0.23 1- 0.16 84' 4.8' B• 42' 8' 0.19 0.10 60, b' 8' 48, 8" 0.26 0.2E 72' Ir 8' I 60• 12' 0.35 0.24 84• 8' 12' 72• 12, 0.30 0.29 98' 8' 12' 1 e4- - 12' 0.39 0.29 NOTES 1. No steps are required when height Is 4' or less. 2. The bottom of the precast catch basin may be sloped to facilitate cleaning. 3. The rectangular frame and grate must be Installed with the flange down. . The frame may be cast Into the adjustment section. 4. Knockouts shall have a wall thickness of 2' minimum to 2,6" maximum. Provide a 1.5' minimum gap between the knockout wall and the outside of the pipe. After the pipe Is Installed, fill the gap with joint mortar In accordance with Standard Specification 9-04.3. 5• All grade rings, risers, and castings shall be set in mortar In accordance with PIPE ALLOWANCES CATCH PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER BASINE247 ALL ,£,�� CP93P SOLID WALL PVC(2)PVC PROFILE WALL (1) 48• -30' 24' 27" 30" 04' 30. - 36• 30• 27' 36' eo" 3e' 42' 36' 36" 42- 72' 42' 54' 42' 36' - 4W B, 64' $B• 1 4e 98• wr 72' ew 36• 48' Standard Specification 9-04.3. + coaugeted Polyethylene Storm p•wor Pipe (Sid. Spec. 9.06.20) lam. spec. M6.12(2)) + �o PUBLIC WORKS CATCH BASIN TYPE 2 STD. PLAN - 201.00 + DEPARTMENT MARCH 2O08 INFLUENT PIPE (MAX DESIGN N ', FLOW <0.5- CFS PER TRENCH) CLEAN OUT WYE o, FROM .PIPE o FLOW TO OTHER BRANCHING CBS AS NECESSARY PLAN N TS od to GAL VA PIPE O.D. o- BOL IS 1' - 0 - 7' 0 a MIN M1N MAX *20q M I 18" O.C. r7 A r r m Q ' PRESSURE TREATED GRADE \\\\\\ .; \/\/\/\ // // /\ 2" GRADE c o BOARD / \ \ \ \ \ \ \ /, / � BOARD NOTCHES cl- " o ' , M1N 6 PERFORATED PIPE LAID FLAT NO "� 4" X 4" SUPPORT POST CLEAN (<59 FINES) 1, THIS TRENCH SHALL BE CONSTRUCTED TO PREVENT Uq" - 1" WASHED POINT DISCHARGE AND/OR EROSION. .^,'• y, ROCK 2. TRENCHES MAY BE PLACED NO CLOSER THAN 50 z tO ° /\\\/\� FEET TO ONE ANOTHER 100 FEET ALONG FLOWLINE . j\\\j\� 3. TRENCH AND GRADE BOARD MUST BE LEVEL. ALIGN Q �\/�//�\�• TO FOLLOW CONTOURS OF SITE. FILTER FABRIC 4. SUPPORT POST SPACING AS REQUIRED BY SOIL CONDITIONS TO ENSURE GRADE BOARD REMAINS c *151'.' MAX FOR FLOW SECTION A -A LEVEL, o CONTROL/WATER QUALITY NTS 0 TREATMENT IN RURAL AREAS 00 VISPERSAL TRENCH DETAIL I' o 1 ER CITY OF RENTON STANDARD PLAN 224.00 NTS N As t D.R. STRONG C l) x C CONSUL TING ENGINEERS a� World Days Before You Di � Y g , r .. �, ENGINEERS PLANNERS SURVEYORS 811 LINK! Underground Location Center 11 5232� cis rsT 620 - 7th AVENUE KIRKLAND, WA 98033 ,. z (ID MT rND r0RWA N • 0425.827.3063 F425.827.2423 W SEE NOTI FRAME DBTAIL SECTION O CATCH BASIN =7' > (®0.69•) - 29'MIN. -3' 1'MIN. 20114' (=0,261 TYP. - Of SEE NOTE 4 -. �(ryP,) �34" (YNDE SIDE) CATCH BASIN TYPE 1 SEE NOTE 2 (TYP.) Y: ' _ = 40' (WIDE SIDE) •CATCH BASIN TYPE 11. 0 L SEE NOTE 1 TOP VIEW SECTION O FRAME DETAIL NOTES 1. The asymmetry of the Combinadon Inlet shall be considered when calculating the offset distance for the catch basin. See SECTION A. 2. The dimensions of the Frame and Hood may vary slightly among dif- ferent manufacturers. The Frame may have cast features Intended CURB OR CURB AND GUTTER to support a grate guard. Hood units shall mount outside of the MATCH TOP of HOOD Frame. The methods for fastening the Safety Bar I Debris Guard Rod TO TOP of CURB (rYPJ / to the Hood may vary. The Hood may include casting lugs. The top of the Hood may be cast with a pattern. Hoop 3, Attach the Hood to the frame with two 3/4" x 2' hex head bolts, nuts, pp�or II4 s7'ALL and oversize washers. The washers shall have diameters adequate BAFETYBARIDEBRISGUARD to assure full bearing across the slots. 20'x 241VANED ORATE 4. When bolt -down grates are specified In the contract, provide two FRAME holes In the frame that are vertically aligned with the grate slots. Tap each hole to accept a 618" x -11 NC x 2' alien head cap screw. Location of bolt -down holes varles among different manufacturers. See BOLT- DOWN DETAIL 6. Only ductile iron Vaned Grates shall be used. a. This plan Is Intended to show the Installation details of a manufao- tured product. It Is not the Intent of this plan to show the specific ISOMETRICVIEW details necessary to fabricate the castings shown on this drawing. 0 n 0 PUBLIC WORKS 'OPEN CURB FACE SM. PLAN - 203.00 -1� DEPARTMENT (FRAME AND GRATE INSTALLATION DETAIL MARCH 2O08 ss .'.. E ., fi 1 te�" _ �r E1 fi a ^sue'. - `a 8 srr � �,{ �... � xk .9 s. ... � e 5 k �a � � a� 8 P 1 H. r r C:....,(. Lb x�.e .E fs I it..a<u.,: YN, 6a' ..,.._z'.w , . i3..8, :..a...". 3 , t, a a . < � c �,,.,, .: , ee a., r�,�o:... . , ,n 6.F .: .n� .,.�,..,<:. REQUIRED PROTECTIOU Discharge Velocity at basign Flow (fps) Greater Less than Minitn-urn Diniensions(l) than or actual to Tyne Thickness Width; Length Height 0 5 Rock tiningt) -1 foot Diameter 8 feet Crown + 6 feet or -I toot 4 x diameter, whichever is greater i t0 Ri raf3 2 feet Diameter 12 feet Crown 6 feet Or + 1 foot or 4 x diameter, 3 x diameter, ',whichever is whichever is greater greater I0 20 Gabion As required AS required As required Crown outfali + :1 foot 20 NIA Engineered energy dissipater required i t) Thew sizes ': .� r , a_vUnl� that erosion 13 dominated by outfal! energy. In many cases sizing will be governed I7 conditions in th cocci . ge receiving vdat;{r... Yg s (1# Rocky lining shall he quarn1 spalls-with gradation as follows - Passing 8-inch square sieve: '100% Passing 3-inch s.quare Sieve: 40 to 6D/nTa;tirtTlrrn Passing q mI14,inch square sieve: D to '10% axir ium Riprap halt be reasonaEaly well graded 1dItIY gfa[tt3ti4n a0 follows: Maxinium stone size: 24 inches (nominal diameter) Median Stone size: 16 incheu Minimum sloth; Size: 4 inches Note.. Rlprap sizing governed by side slopes on outlet channel is assumod to be approxihiately 3 f. OUTFALL PROTECTION SIZING AS -BUILT NO AS-BUIL T INFORMA 77ON ON THIS SHEET T. I CER77FY THAT THE INFORMA 77ON SHOWN HEREON WHICH WAS AS -BUILT BY D,R. S7RONG, AND MAY INCLUDE LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND AS -BUILT COMMENTS, ACCURATELY REFLECTS EXIS77NG FIELD COND177ONS AS DETERMINED BY ME OR UNDER MY DIRECT SUPER WSION ON 7HIS DATE- 1211012018." - w 0+14I'f¢ klirong Ts�l4 flp Eiij3 (9' r17111 } M + - .: fn1n: �f q PkAN BITS plant rack '1cllaove crthvrl 1�4111 ,IONS Qf elizinnel fear R A 4 < 8+ ope site of channel (or"A" > El' � ... f l' iilln.. ;�_ �iischar pl(_10 x ' r• l lilter;faiart� llf7 I' or 2+ r c -c n o_..tftlkfte r � , Utl( @f'F4 Cti T See table 4.4.tA'. SECTION A -A tT OUTFALL PROTECTION DETAIL R-392223 APPROVED FOR CONSTRUCTION N SUBJECT TO ERRORS AND OMISSIONS 0) BY: DATE: BY: DATE: W 0 BY: DATE: n.. BY: DATE: Lla Q LJI�OOV SURVEYED: SJS SCALE: AS NOTED VERTICAL: NAVO 1988 HORIZONTAL: NAD 1983/1991 DATUM DATUM ...; � I T \/ 0 IT •....._ ,.' • RENT 0 N � Planning/Building/Public works Dept. .. - AVANA RIDGE PUD STORM DRAINAGE DETAILS 10615 SE 172ND ST, RENTON, WA f� Q R Q `/1�OOQ86V 865 815008867 DATE: 12.10.18 Q Q Z - Q > DESIGNED: �'`-P FIELOBDot<: PAGE: - DRAWN: BEN ONE INCH CHECKED: I AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY DRAWING NO: C22 NO. REVISION BY DATE p AP AfPR APPROVED: Ii�, SHEET; OR 22 22J Q DRS PROJECT NO. 15088