Loading...
HomeMy WebLinkAboutR-390706NOTE: O co I i 0 W (WEST) 26.50' R 14.19'-14.06' WIDTH VARIES DEDICATED PUBLIC R/W 13.5' 2% MAX. g5' SIDEWALK PER-/ C.O.R. STD. PLAN 102 8' LANDSCAPE STRIP rr VERTICAL CURB & GUTTER O = PER C.O.R. STD PLAN 101 0 Q W W W w z Iw U ,g w �z o� U w 12.44'-12.31' I Q z WIDTH VARIES 0 3 v EXISTING R/W 6' 2 % I- A PORTION OF THE SE 1/4, SECTION 10, TOWNSHIP 23 N., RANGE 5 EAST, W.M., CITY OF RENTON, WASHINGTON ( EAST) 19.0' R/ 13' VARIES 26.5' I ASPHALT (EXI TING) \-SAW CUT LINE 2" GRIND AND OVERLAY 4" MIN. CLASS "B" ASPHALTIC CONCRETE PAVEMENT- 2-2" LIFTS REQUIRED 6"MIN. CRUSHED SURFACING TOP COURSE CRUSHED SURFACING BASE COURSE TO BE DETERMINED BY FIELD CONDITIONS BY GEOTECHNICAL ENGINEER. ILWACO PLACE NE ROAD SECTION SECTION A -A, LOOKING NORTH 3LF.. 12" D.I.@S=1.00% REMOVE EX. CB USE 12" COUPLING TO CONNECT TO EXISTING RS (PUBLIC) sss �0 CB#8, TYPE 1 RIM=456.36 IE=453.42, 12"(S (PUBLIC) s TTl � � cl) mzK: II II II �� P,-�� P, � � CP CD CO (.0Ln R w orn? s STA. 10+00.0, ILWACO PLACE NE STA. 33+44.15, NE 5th PLACE m �S = 0119 �S 2 s'iss EX. ADA RAMP OE CB#1A, TYPE II-48"0 RIM=455.31 4 IE=449.46, 12"(W) IE=449.36, 2-8"(E) OF 20LF., 12" SD @S=0.45% A4 OG 2 EACH, 18LF., 8" D.I.@S=2.39% 0 CURB RETURN TABLE R=25.00' C 1 L _39.88' A-88°36'32" PC=33+05.22, 13.00' LT. TBC=457.02 DELTA/2 TBC=456.35 PT=10+38.93, 13.00' LT. TBC=455.70 R=25.00' C2 L _38.64' A-88°33'47" PC=13+ 13.91, 13.00' LT. TBC=455.95 DELTA/2 TBC=456.15 PT=23+07.20, 10.50' RT. TBC=456.35 PERPENDICULAR CURB RAMP PER WSDOT STD. PLAN F-40.15-02 SEE SHEET 7 CA w + 0 Q d I 1 om , VA IAB d '.. /W F z SCl m E i r--i- I R xRSss G SssR ly /xRSS L .S �coEl e0 D � �2 M = MT 44 CB 1, TYPE III" RIM=455.08 IE=449.03, 8"�W)-2 EACH IE=449.03, 12 (N,S) (PUBLIC) C GRADING ADA RAMP NW CORNER NE 5TH PLACE & ILWACO PLACE NE SCALE: 1 "=5' GRADING ADA RAMP SW CORNER NE 6TH STREET & ILWACO PLACE NE SCALE: 1 "=5' 10' PRIVATE FRANCHISE TRACT A ! EASEMENT, TYPICAL VAULT - SEE SHEET 9 SEE SHEET 7 95LF., 12" SD @S=1.007. /Fn ii PUBLIC ALLEY PUBLIC ( ) LOT 6 1 x 66� LOT 7 STREET LIGHTS TYPICAL 4 _ SEE STREET LIGHTING PLANS 2 � - QLF _j 5' -sQ _@5=16_157- - �I RSS (PUBLIC) -��. d - �- I----- - - - - - - - - - - - - - - - - - - - ------------ - g • I • A O 9 d9 ad' .. b, d da'w: .. •• •: 9. Cd•d'd d' w d � 9• 9 dd < 7��� il 1 *m0 x - RS � R R S� 9) 1 1 3.11 1,11.R �R.. T T �u �4 70LF. 12" SD @S=3.01 % (PUBLIC) _ _ Ln _Dd CB#3, TYPE 1 N = RIM=455.09 ; IE=452.10, 12"(N) p (PUBLIC) 12+ - LWAC0 PLACE NE mSTA. 11+36.22, TRACT B(PUBLIC)00 N mrnCB#2, TYPE 1-L W/THRU CURB INLET o 0RIM=454.64 IE=450.09, 12"(N) IE=449.99, 12"(S) IE=449.91, 15"(W) (PUBLIC) x >1, Ln m X Ln 0 N cli 39LF., 12" (PUBLIC) LOT 5 CONSTRUCTION NOTES EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDERGROUND UTILIITES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION. M_I■M_70Oril-7�-r lIINllrl ii�i OAINSTALL 16' DRIVEWAY APPROACH R1BPER STD. PLAN #104.3 INSTALL 20' DRIVEWAY APPROACH R1B PER STD. PLAN #104.3 INSTALL STREET SIGN PER DWG. NAME G013 STREET NAMES "NE 5th PLACE" AND "ILWACO PLACE NE" INSTALL STREET SIGN PER DWG. NAME G013 STREET NAMES "NE 6th STREET" AND "ILWACO PLACE NE" ALL CATCH BASIN GRATES SHALL BE RECTANGULAR VANED GRATES PER C.O.R. STD. PLAN 204.20 UNLESS OTHERWISE SPECIFIED. CB#6, TYPE 1 RIM=455.85 IE=452.90, 12(W) IE=452.88, 12(SE) (PUBLIC),_)aOZR �0� EX. ADA RAMP �z�Ln c010 0 KC4m CA 4 INT'X, ILWACO AVENUE NE `n - STA. 23+08.39, NE 6th STREET SEE SHEET 8 ,� °° °'d d+ ILWACO AVENUE NE .d0p••C2 I ). ss zoo z 13+00LIMITS OF 2" GRIND AND OVERLAY �99LF. 12" SD @S=1.49% CB#5, TYPE 1i RIM=455.50 IE=452.25, 12" (PUBLIC) CB#4, TYPE 1RIM=454.99 IE=451.04, 12" (PUBLIC) NOTE: GRIND AND OVERLAY LIMITS AND TRENCH RESTORATION SHALL BE PER C.O.R. STD. PLANS H-032 AND H-032.1 CENTERLINE OF DRIVEWAY STATIONING 1 R AS SHOWN ss- ��EX. ADA RAMPON AS-BUILTS frl Fri a? 'r EX. ADA IfLn _��2 z Uri Dncn z II � c0 (D� 9 75 FTI F9 e>606Ln \STA. 13+48.47ILWACO PLACE NE STA. 23+44.32, NE 6th GRAPHIC SCALE 0 10 20 40 N Ln I- O 00O O O O O O O O O �Ln r7O O N r7 Ln CO I- 00 O OLn Iri ur Lri Lri Lri Ili ur Lri ur Lri Lri ur LriIn Ln Ln Ln Ln Ln Ln Ln Ln Ln Ln Ln Ln Ln LnAS-BUILT 12-12-2018I inch = 20 feet 460 ..:... .. ...... .. ...... .460 CONSTRUCTION RECORD DRAWING m THIS CONSTRUCTION RECORD DRAWING IS A COPY OF A CAD FILE PREPARED PROFILE EXITING Q PROFILE TPCBY OFFE ENGINEERS, PLLC AND HAS BEEN EDITED TO REFLECT FIELD VERIFIED INVERT AND RIM ELEVATIONS OF THE STORM, SANITARY AND WATER SYSTEM. FIELD CENTERLINE (TOP BACK OF CURB) VERIFIED INVERT AND RIM ELEVATIONS WERE PROVIDED BY TERRANE SURVEYING, INC., - - - - - = - -- -'- - - - T I 455 ON DECEMBER 10, 2018. THE ON -SITE PRIVATE STORM DRAINAGE AND PUBLIC/PRIVATE ..........:...........-.�.�.-. ..� LL. .� ._ ._ - . .-.___ .-.-.-.-.-.-.-.-.-.-.-.-.-. T. - ............................... .................. ..... ......... WATER AND SEWER SYSTEMS WERE INSTALLED IN ACCORDANCE WITH THE APPROVED : VAULT:OVERFLOW=454.10 : : : : : : : : wg z - - - - - - - - - - - - - - - - - - - - - z PLANS AND THE DOCUMENTED FIELD REVISIONS AND FUNCTION AS INTENDED. 4w ZO cn r APPROX. WM 4 wLF'°12 : I � 99LF , 12 SD C�?S=1.49%g REC0RD DRAW NGS R-390706 SD @S95LF.,12'SD @S=1.00%450......L�..............:...........:................:................:................:............:................:................:................:................:.........�. �....450 z I O EX. 1:2 SD I OOI : : EX. S.S. MAIN : : : : I OU U IN COMPLIANCE WITH CITY OF RENTON STANDARDS "Q �: zl� I I I x 4 CB 5 z EX. 8" W.M. 449.96-450.62 NEW 8" STM(449.20-449.87) INSTALL ETHAFORM PAD AT CROSSING C) ELEVATIONS ICB#3 �4 CB 2 A4 CB 4 RIM=455.50 RIM=455.09 RIM=454.99 IE=452.25, 12"(S,NT 445........:.....4. CB 1 RIM=454.64: IE=.4.5;2..Q3.,..1.2".(.N)................:................:.IE=450:09; 12" N ............................ IE ' 451:0.4; ..12"(N;S).................. 39LF:...12.,, . SD ..@5=1:RIM=455.08 (..)...........................IE=449.03, 12" (EX.)-NS IE=449.99, :12 I:LWAC 0 PLACE NE. 10+00 IE=449.03, 8"(W)-2 EACH IE=449.91, :15" W)CB#6 RIM=455 85 OFFE ENGINEERS 13932 SOUTHEAST 159TH PLACE RENTON, WASHINGTON 98058 PHONE: 425-260-3412 CONTACT: DARRELL OFFE, P.E. L. WASyo��'C>' 5 4 2 2 27460STE 0 o�FSS AL� �N���\ 1 04/04/2019 N0. 1 1 +00 INDICATE DEDICATION OF PUBLIC ROW AS-BUILTS SIDEWALK RE -ALIGNMENT FOR EX. TREE FIELD CONDITIONS W/EX. W.M. CONFLICT EXISTING TREE REMOVED IN FIELD ill 1016MIffiI 12+00 D . L. 0. 04/04/ 19 SURVEYED: D.L.O. 12/18/18 DESIGNED: D.L.O. 7/12/18 D.L. OFFE, P.E. D.L.O. 3/05/18 DRAWN: D.L.O. 1 1/15/18i i CHECKED: HORIZONTAL SCALE: 1 =20 VERTICAL SCALE: 1 "=5' SCALE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 ONE INCH DATU M AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 13+00 IE=452.90, 12:" W) IE=452.88, 12:: SE) CITY OF R RENTON VZOOF Planning/Building/Public Works Dept. 445 It co LO O W,u co MTC) OQ 0O i i1 DATE: O MEAD SHORT PLAT o�/04/2019 = TUSCANY CONSTRUCTION, LLC () PAGE: ILWACO PLACE NE DRAWING N0: 522 HOQUTAM AVENUE NE W RENTON, WASHINGTON SHEET: OF: 20